HomeMy WebLinkAboutB18801442 truss layoutFrame Dormer Hip InWith 2x6 RaftersFrame Dormer Hip InWith 2x6 RaftersHold Hanger Up 1- 3/4"for Trusses "T04"MUS26HTU26HTU26HTU26HTU26MUS26MUS26MUS26MUS26MUS26MUS26MUS26MUS26MUS26MUS26Trusses "M03" sit on 2ndFloor Walls2x4 LedgerComment 12x4 Nailer for DeckingComment 22x4 Nailer for DeckingComment 32x4 LedgerHTU26HTU26HGUS26-2HGUS26-22x4 LedgerTrusses "T23 & T24" siton 2nd Floor Walls2x4 Nailer for DeckingComment 42x4 Nailer for DeckingComment 52x4 Nailer for DeckingComment 6Framer to add overhangs toform curve on roof atoverhangComment 7Set Valley gable "V23"on top of roof deckingComment 92x10 Ledger HoldLedger Up 1-1/4"Above Wall Plate Ht2x10 Ledger HoldLedger Up 1-1/4"Above Wall Plate HtTrusses "T10, T11 & T12set on Flush 2x8 BeamTrusses "T09 & T10 seton Flush 2x8 Beam2x4 Ledger2x4 LedgerT01CT01BT01AT18GE02T03MG01M01M02T05T06T07TG01J15J16GE04TG03J03J01TG05T19T20T21T22M06GR02G R 0 1 GE03T02J04J05J06V20V21V22V20V21V22GE06V12V13V14V17V18V19V23PB01PB03PB04PB05PB06PB07PB08PB09PB10TG02(2)
PB02(10)
T04(6)M05(7)J02(3)T01(7)T24(3)T23(4)M03(7)53-11-003-00-0026-00-0082-11-0082-11-0014-08-0018-00-0834-04-089-07-0026-11-0812-00-002-00-002-00-002-00-002-00-002-00-002-00-002-00-002-00-002-00-002-00-002-00-002-00-002-00-002-00-002-00-002-00-002-00-002-00-002-00-002-00-002-00-002-00-002-00-002-00-002-00-002-00-002-00-002-00-002-00-002-00-002-00-002-00-002-00-002-00-002-00-002-00-001-03-082-00-002-00-002-00-002-00-002-00-002-00-001-06-0014-11-0818-11-0815-00-0048-11-002-06-0023-03-0010-00-08 3-08-08 11-11-0025-00-008-081-05-082-00-002-00-002-00-002-00-002-00-002-00-001-06-0810-052-10-0710-052-10-072-01-082-00-002-00-001-07-0812-11-00 10-04-001-00-005-00-00 2-11-00 7-01-00 2-11-002-00-002-00-002-00-002-00-002-00-002-00-002-00-002-00-002-00-001-07-082-02-001-08-002-00-002-00-002-00-002-00-002-00-00GE05T28TG04T17AT16T15T14T12T11TG06J12J12J13J13J08J08J09J14J 1 0 V06V07V08V09V01V02V15V16V10AV10V11V03V04V05J11(3)T08(6)T13(3)T17(2)T10(2)T09(2)J07(5)T25(4)T26(3)T27(2)T29(7)2-00-002-00-002-00-002-00-002-00-002-00-002-00-002-00-002-00-002-00-002-00-002-00-002-00-002-00-002-00-002-00-002-00-002-00-002-00-002-00-002-00-002-00-002-00-002-00-002-00-002-00-002-00-002-00-002-00-002-00-002-00-002-00-002-00-002-11-001-04-001-08-002-00-002-00-002-00-122-00-122-00-002-00-002-00-002-00-002-00-002-00-002-00-002-00-002-00-003-00-002-00-002-00-001-07-041-07-042-00-002-00-003-00-002-00-002-00-002-00-002-00-002-00-001-02-00IRC 2006TPI 200220TLL -10TDL -10BDLPulte1 hertiage at springmill1/4"=1'May 4, 2018ABB18801442CUSTOMER:LOCATION:MODEL:JOB #:DATE:DESIGNER: DESIGN INFORMATION:SCALE:9028 Old SR 67 SouthMooresville, IN 46158(317) 834-5380Truss Placement Guide1) This layout is intended for the purpose of truss locationand placement only. Refer to the building plans for actualbuilding construction.2) All dimensions shown 00-00-00 are in feet-inches-sixteenths.3) Trusses are spaced 24" on center unless otherwise noted.4) Do not cut or modify trusses.5) Refer to the individual truss design drawings for the locationof member bracing, uplift and truss end reactions.6) Installation of all temporary and permanent bracing isessential. See truss drawings, BCSI-B2 Summary Sheetand building designer requirements.