HomeMy WebLinkAboutLegacy Ridge 71 truss detailsRe:
The seal on these drawings indicate acceptance of professional engineering responsibility solely for the
truss components shown. The suitability and use of this component for any particular building is the
responsibility of the building designer, per ANSI/TPI 1.
The truss drawing(s) referenced below have been prepared by MiTek USA, Inc. under my direct supervision
based on the parameters provided by Timberland Home Center-Brazil, IN.
Liu, Xuegang
SOUTHILL C STANDARD
Pages or sheets covered by this seal: I23659112 thru I23659158
My license renewal date for the state of Indiana is July 31, 2016.
Lumber design values are in accordance with ANSI/TPI 1 section 6.3
These truss designs rely on lumber values established by others.
1500058
14515 North Outer Forty Drive
Suite 300
Chesterfield, MO 63017-5746
314-434-1200
MiTek USA, Inc.
February 12,2015
Job
1500058
Truss
A
Truss Type
COMMON
Qty
10
Ply
1
SOUTHILL C STANDARD
Job Reference (optional)
I23659112
7.430 s Jul 25 2013 MiTek Industries, Inc. Wed Feb 11 15:05:05 2015 Page 1 Timberland Lumber Company, Indianapolis, IN 46222
ID:6wSYySsChxEClNJ8ETXMjTzZ3cH-u1?fhkWSfTU79MCuKYJdSU2enQrkJ1DSfiIh3VzmAby
Scale = 1:76.3
1
2 3
4
5
6
7 8
9
10
15 14 13 12 11
16 17
3x6
5x6
3x6
5x6
3x6 3x4
2x4
3x4
3x8
3x4
3x4
2x4
6x12
5x6
5x6
3x6
9-11-0
9-11-0
19-3-15
9-4-14
28-8-14
9-4-15
37-8-0
8-11-2
6-9-0
6-9-0
11-10-8
5-1-8
19-3-15
7-5-7
26-9-6
7-5-7
31-10-13
5-1-8
37-8-0
5-9-3
0-6-611-9-111-1-57.00 12
LOADING (psf)
TCLL
(Roof Snow=20.0)
TCDL
BCLL
BCDL
20.0
10.0
0.0
10.0
SPACING
Plates Increase
Lumber Increase
Rep Stress Incr
Code
2-0-0
1.15
1.15
YES
IRC2006/TPI2002
CSI
TC
BC
WB
(Matrix)
0.93
0.88
0.36
DEFL
Vert(LL)
Vert(TL)
Horz(TL)
in
-0.26
-0.73
0.14
(loc)
1-15
1-15
10
l/defl
>999
>615
n/a
L/d
240
180
n/a
PLATES
MT20
Weight: 168 lb FT = 0%
GRIP
197/144
LUMBER
TOP CHORD 2x4 SPF No.2
BOT CHORD 2x4 SPF No.2
WEBS 2x4 SPF Stud/No.3 *Except*
4-13,5-13,6-13: 2x4 SPF No.2
WEDGE
Left: 2x4 SPF Stud/No.3
SLIDER Right 2x8 SP No.2 3-6-1
BRACING
TOP CHORD Structural wood sheathing directly applied or 2-2-0 oc purlins.
BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing.
WEBS 1 Row at midpt 4-13, 6-13
MiTek recommends that Stabilizers and required cross bracing
be installed during truss erection, in accordance with Stabilizer
Installation guide.
REACTIONS (lb/size)1=1501/Mechanical, 10=1501/Mechanical
Max Uplift1=-96(LC 6), 10=-96(LC 6)
FORCES (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
TOP CHORD 1-2=-2426/204, 2-4=-2208/219, 4-5=-1565/236, 5-6=-1569/236, 6-8=-2015/206,
8-10=-2231/190
BOT CHORD 1-15=-97/1995, 13-15=-18/1731, 11-13=-16/1663, 10-11=-73/1726
WEBS 4-15=0/492, 4-13=-731/149, 5-13=-94/1038, 6-13=-645/146, 6-11=0/329
NOTES
1) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=30ft; Cat. II; Exp B; enclosed; C-C Exterior(2); cantilever left and right
exposed ; end vertical left and right exposed; Lumber DOL=1.33 plate grip DOL=1.33
2) TCLL: ASCE 7-05; Pf=20.0 psf (flat roof snow); Category II; Exp B; Fully Exp.; Ct=1.1
3) Unbalanced snow loads have been considered for this design.
4) This truss has been designed for basic load combinations, which include cases with reductions for multiple concurrent live loads.
5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
6) Refer to girder(s) for truss to truss connections.
7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 96 lb uplift at joint 1 and 96 lb uplift at joint
10.
8) "Semi-rigid pitchbreaks including heels" Member end fixity model was used in the analysis and design of this truss.
9) Warning: Additional permanent and stability bracing for truss system (not part of this component design) is always required.
LOAD CASE(S) Standard
Design valid for use only with MiTek connectors. This design is based only upon parameters shown, and is for an individual building component. Applicability of design parameters and proper incorporation of component is responsibility of building designer - not truss designer. Bracing shown is for lateral support of individual web members only. Additional temporary bracing to insure stability during construction is the responsibillity of theerector. Additional permanent bracing of the overall structure is the responsibility of the building designer. For general guidance regardingfabrication, quality control, storage, delivery, erection and bracing, consult 14515 N. Outer Forty, Suite #300
Chesterfield, MO 63017
ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 781 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information
February 12,2015
Job
1500058
Truss
AG
Truss Type
GABLE
Qty
1
Ply
1
SOUTHILL C STANDARD
Job Reference (optional)
I23659113
7.430 s Jul 25 2013 MiTek Industries, Inc. Wed Feb 11 15:05:06 2015 Page 1 Timberland Lumber Company, Indianapolis, IN 46222
ID:6wSYySsChxEClNJ8ETXMjTzZ3cH-MEY1u4X4Qmc_nWm4uFqs_hbowq9c2QabuM1FbxzmAbx
Scale = 1:78.6
Sheet Front
Right Option 0-9-1
1 Ply 1/2 x 4 x 8 Duramate
1
2 3
4
5
6
7 8
9
15 14 13 12 11 10
21 22
3x6
5x6
3x6
5x6
3x6 3x4
2x4
3x4
3x8
3x4
3x4
4x6
2x8
3x6
2x4
2x4
2x4
2x4
2x4
2x4
3x6
9-11-0
9-11-0
19-3-15
9-4-15
28-8-14
9-4-15
36-10-15
8-2-1
37-8-0
0-9-1
6-9-0
6-9-0
11-10-8
5-1-8
18-0-0
6-1-8
19-3-15
1-3-15
26-9-6
7-5-7
31-10-13
5-1-7
37-8-0
5-9-3
0-6-611-9-111-1-57.00 12
Plate Offsets (X,Y): [19:0-1-9,0-1-0]
LOADING (psf)
TCLL
(Roof Snow=20.0)
TCDL
BCLL
BCDL
20.0
10.0
0.0
10.0
SPACING
Plates Increase
Lumber Increase
Rep Stress Incr
Code
2-0-0
1.15
1.15
NO
IRC2006/TPI2002
CSI
TC
BC
WB
(Matrix)
0.97
0.97
0.61
DEFL
Vert(LL)
Vert(TL)
Horz(TL)
in
-0.26
-0.73
0.13
(loc)
1-15
1-15
10
l/defl
>999
>618
n/a
L/d
240
180
n/a
PLATES
MT20
Weight: 186 lb FT = 0%
GRIP
197/144
LUMBER
TOP CHORD 2x4 SPF No.2
BOT CHORD 2x4 SPF No.2
WEBS 2x4 SPF Stud/No.3 *Except*
4-13,5-13,6-13: 2x4 SPF No.2
OTHERS 2x4 SPF Stud/No.3
WEDGE
Left: 2x4 SPF Stud/No.3
BRACING
TOP CHORD Structural wood sheathing directly applied, except end verticals.
BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing.
WEBS 1 Row at midpt 4-13, 6-13, 8-10
MiTek recommends that Stabilizers and required cross bracing
be installed during truss erection, in accordance with Stabilizer
Installation guide.
REACTIONS (lb/size)1=1495/Mechanical, 10=1495/Mechanical
Max Horz 1=4(LC 6)
Max Uplift1=-96(LC 6), 10=-96(LC 6)
FORCES (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
TOP CHORD 1-2=-2415/203, 2-4=-2197/218, 4-5=-1554/235, 5-6=-1555/235, 6-8=-2031/206,
8-9=-364/85, 9-10=-313/78
BOT CHORD 1-15=-101/1986, 13-15=-22/1721, 11-13=-18/1636, 10-11=-78/1728
WEBS 4-15=0/492, 4-13=-729/149, 5-13=-93/1020, 6-13=-621/144, 6-11=0/347,
8-10=-1860/106
NOTES
1) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=30ft; Cat. II; Exp B; enclosed; C-C Exterior(2); cantilever left and right
exposed ; end vertical left and right exposed; Lumber DOL=1.33 plate grip DOL=1.33
2) Truss designed for wind loads in the plane of the truss only. For studs exposed to wind (normal to the face), see Standard Industry
Gable End Details as applicable, or consult qualified building designer as per ANSI/TPI 1.
3) TCLL: ASCE 7-05; Pf=20.0 psf (flat roof snow); Category II; Exp B; Fully Exp.; Ct=1.1
4) Unbalanced snow loads have been considered for this design.
5) This truss has been designed for basic load combinations, which include cases with reductions for multiple concurrent live loads.
6) Gable studs spaced at 1-4-0 oc.
7) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
8) Refer to girder(s) for truss to truss connections.
9) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 96 lb uplift at joint 1 and 96 lb uplift at joint
10.
10) "Semi-rigid pitchbreaks including heels" Member end fixity model was used in the analysis and design of this truss.
11) Warning: Additional permanent and stability bracing for truss system (not part of this component design) is always required.
LOAD CASE(S) Standard
Design valid for use only with MiTek connectors. This design is based only upon parameters shown, and is for an individual building component. Applicability of design parameters and proper incorporation of component is responsibility of building designer - not truss designer. Bracing shown is for lateral support of individual web members only. Additional temporary bracing to insure stability during construction is the responsibillity of theerector. Additional permanent bracing of the overall structure is the responsibility of the building designer. For general guidance regardingfabrication, quality control, storage, delivery, erection and bracing, consult 14515 N. Outer Forty, Suite #300
Chesterfield, MO 63017
ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 781 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information
February 12,2015
Job
1500058
Truss
AG1
Truss Type
GABLE
Qty
1
Ply
1
SOUTHILL C STANDARD
Job Reference (optional)
I23659114
7.430 s Jul 25 2013 MiTek Industries, Inc. Wed Feb 11 15:05:07 2015 Page 1 Timberland Lumber Company, Indianapolis, IN 46222
ID:6wSYySsChxEClNJ8ETXMjTzZ3cH-qQ6P6PYiB4krOgLGRzL5Xv7_6EVxnxlk70no7NzmAbw
Scale = 1:76.9
Sheet Back
Right Option 8-9-1
1 Ply 1/2 x 4 x 8 Duramate
1 2
3
4
5
6
7 8
9
10
11
16 15 14 13 12
47 48
3x6
5x6
3x8
6x6
3x6 3x4
3x4
3x8
3x4
6x14
6x12
5x6
5x6
3x6
9-11-0
9-11-0
19-3-15
9-4-15
28-8-14
9-4-15
28-10-15
0-2-1
37-8-0
8-9-1
-0-11-4
0-11-4
6-9-0
6-9-0
11-10-8
5-1-8
14-0-0
2-1-8
19-3-15
5-3-15
26-9-6
7-5-7
31-10-13
5-1-7
37-8-0
5-9-3
0-6-611-9-111-1-57.00 12
Plate Offsets (X,Y): [2:Edge,0-3-2], [12:0-3-0,0-3-0], [25:0-1-11,0-1-0]
LOADING (psf)
TCLL
(Roof Snow=20.0)
TCDL
BCLL
BCDL
20.0
10.0
0.0
10.0
SPACING
Plates Increase
Lumber Increase
Rep Stress Incr
Code
2-0-0
1.15
1.15
NO
IRC2006/TPI2002
CSI
TC
BC
WB
(Matrix)
0.94
0.96
0.36
DEFL
Vert(LL)
Vert(TL)
Horz(TL)
in
-0.25
-0.70
0.14
(loc)
2-16
2-16
11
l/defl
>999
>644
n/a
L/d
240
180
n/a
PLATES
MT20
Weight: 253 lb FT = 0%
GRIP
169/123
LUMBER
TOP CHORD 2x4 SPF No.2 *Except*
6-8: 2x4 SPF-S 1650F 1.6E
BOT CHORD 2x4 SPF No.2
WEBS 2x4 SPF Stud/No.3 *Except*
5-14,6-14,7-14: 2x4 SPF No.2
OTHERS 2x4 SPF Stud/No.3
WEDGE
Left: 2x4 SPF Stud/No.3
SLIDER Right 2x8 SP No.2 3-8-14
BRACING
TOP CHORD Structural wood sheathing directly applied.
BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing.
WEBS 1 Row at midpt 5-14, 7-14
MiTek recommends that Stabilizers and required cross bracing
be installed during truss erection, in accordance with Stabilizer
Installation guide.
REACTIONS (lb/size)2=1567/Mechanical, 11=1500/Mechanical
Max Horz 2=15(LC 6)
Max Uplift2=-132(LC 6), 11=-96(LC 6)
FORCES (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
TOP CHORD 2-3=-2418/199, 3-5=-2202/215, 5-6=-1564/235, 6-7=-1567/235, 7-9=-2016/205,
9-11=-2233/189
BOT CHORD 2-16=-90/1986, 14-16=-17/1727, 12-14=-15/1661, 11-12=-72/1728
WEBS 5-16=0/490, 5-14=-727/148, 6-14=-94/1036, 7-14=-652/146, 7-12=0/332
NOTES
1) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=30ft; Cat. II; Exp B; enclosed; C-C Exterior(2); cantilever left and right
exposed ; end vertical left and right exposed; Lumber DOL=1.33 plate grip DOL=1.33
2) Truss designed for wind loads in the plane of the truss only. For studs exposed to wind (normal to the face), see Standard Industry
Gable End Details as applicable, or consult qualified building designer as per ANSI/TPI 1.
3) TCLL: ASCE 7-05; Pf=20.0 psf (flat roof snow); Category II; Exp B; Fully Exp.; Ct=1.1
4) Unbalanced snow loads have been considered for this design.
5) This truss has been designed for greater of min roof live load of 16.0 psf or 2.00 times flat roof load of 20.0 psf on overhangs
non-concurrent with other live loads.
6) This truss has been designed for basic load combinations, which include cases with reductions for multiple concurrent live loads.
7) All plates are 2x4 MT20 unless otherwise indicated.
8) Gable studs spaced at 1-4-0 oc.
9) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
10) Refer to girder(s) for truss to truss connections.
11) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 132 lb uplift at joint 2 and 96 lb uplift at
joint 11.
12) "Semi-rigid pitchbreaks including heels" Member end fixity model was used in the analysis and design of this truss.
13) Warning: Additional permanent and stability bracing for truss system (not part of this component design) is always required.
LOAD CASE(S) Standard
Design valid for use only with MiTek connectors. This design is based only upon parameters shown, and is for an individual building component. Applicability of design parameters and proper incorporation of component is responsibility of building designer - not truss designer. Bracing shown is for lateral support of individual web members only. Additional temporary bracing to insure stability during construction is the responsibillity of theerector. Additional permanent bracing of the overall structure is the responsibility of the building designer. For general guidance regardingfabrication, quality control, storage, delivery, erection and bracing, consult 14515 N. Outer Forty, Suite #300
Chesterfield, MO 63017
ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 781 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information
February 12,2015
Job
1500058
Truss
B
Truss Type
COMMON
Qty
6
Ply
1
SOUTHILL C STANDARD
Job Reference (optional)
I23659115
7.430 s Jul 25 2013 MiTek Industries, Inc. Wed Feb 11 15:05:08 2015 Page 1 Timberland Lumber Company, Indianapolis, IN 46222
ID:6wSYySsChxEClNJ8ETXMjTzZ3cH-JcgnJlZKyOsi0qwS?gtK36g8VesFWPtuLgWLfqzmAbv
Scale = 1:73.0
1 2
3
4
5
6
7
8
9
10
11
16 15 14 13 12
17 18
3x6
5x6
3x6
5x6
3x6 3x8
3x4
3x4
2x4
3x4
3x4
2x4
5x6
3x6
6-11-14
6-11-14
18-0-0
11-0-2
29-0-2
11-0-2
36-0-0
6-11-14
-0-11-4
0-11-4
3-7-8
3-7-8
10-6-5
6-10-13
18-0-0
7-5-11
25-5-11
7-5-11
32-4-8
6-10-13
36-0-0
3-7-8
36-11-4
0-11-4
0-6-611-0-60-6-67.00 12
LOADING (psf)
TCLL
(Roof Snow=20.0)
TCDL
BCLL
BCDL
20.0
10.0
0.0
10.0
SPACING
Plates Increase
Lumber Increase
Rep Stress Incr
Code
2-0-0
1.15
1.15
YES
IRC2006/TPI2002
CSI
TC
BC
WB
(Matrix)
0.96
0.96
0.30
DEFL
Vert(LL)
Vert(TL)
Horz(TL)
in
-0.27
-0.76
0.13
(loc)
14-16
14-16
10
l/defl
>999
>565
n/a
L/d
240
180
n/a
PLATES
MT20
Weight: 151 lb FT = 0%
GRIP
197/144
LUMBER
TOP CHORD 2x4 SPF No.2
BOT CHORD 2x4 SPF No.2
WEBS 2x4 SPF Stud/No.3 *Except*
6-14,7-14,5-14: 2x4 SPF No.2
WEDGE
Left: 2x4 SPF Stud/No.3, Right: 2x4 SPF Stud/No.3
BRACING
TOP CHORD Structural wood sheathing directly applied.
BOT CHORD Rigid ceiling directly applied or 2-2-0 oc bracing.
WEBS 1 Row at midpt 7-14, 5-14
MiTek recommends that Stabilizers and required cross bracing
be installed during truss erection, in accordance with Stabilizer
Installation guide.
REACTIONS (lb/size)2=1493/0-3-8 (min. 0-2-5), 10=1493/0-3-8 (min. 0-2-5)
Max Uplift2=-127(LC 6), 10=-127(LC 6)
FORCES (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
TOP CHORD 2-3=-2390/190, 3-5=-2215/177, 5-6=-1539/214, 6-7=-1539/214, 7-9=-2215/177,
9-10=-2390/190
BOT CHORD 2-16=-107/1954, 14-16=-26/1683, 12-14=-26/1683, 10-12=-107/1954
WEBS 6-14=-80/1020, 7-14=-675/169, 7-12=0/431, 5-14=-675/169, 5-16=0/431
NOTES
1) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=30ft; Cat. II; Exp B; enclosed; C-C Exterior(2); cantilever left and right
exposed ; end vertical left and right exposed; Lumber DOL=1.33 plate grip DOL=1.33
2) TCLL: ASCE 7-05; Pf=20.0 psf (flat roof snow); Category II; Exp B; Fully Exp.; Ct=1.1
3) Unbalanced snow loads have been considered for this design.
4) This truss has been designed for greater of min roof live load of 16.0 psf or 2.00 times flat roof load of 20.0 psf on overhangs
non-concurrent with other live loads.
5) This truss has been designed for basic load combinations, which include cases with reductions for multiple concurrent live loads.
6) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 127 lb uplift at joint 2 and 127 lb uplift at
joint 10.
8) "Semi-rigid pitchbreaks including heels" Member end fixity model was used in the analysis and design of this truss.
9) Warning: Additional permanent and stability bracing for truss system (not part of this component design) is always required.
LOAD CASE(S) Standard
Design valid for use only with MiTek connectors. This design is based only upon parameters shown, and is for an individual building component. Applicability of design parameters and proper incorporation of component is responsibility of building designer - not truss designer. Bracing shown is for lateral support of individual web members only. Additional temporary bracing to insure stability during construction is the responsibillity of theerector. Additional permanent bracing of the overall structure is the responsibility of the building designer. For general guidance regardingfabrication, quality control, storage, delivery, erection and bracing, consult 14515 N. Outer Forty, Suite #300
Chesterfield, MO 63017
ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 781 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information
February 12,2015
Job
1500058
Truss
BG
Truss Type
GABLE
Qty
1
Ply
1
SOUTHILL C STANDARD
Job Reference (optional)
I23659116
7.430 s Jul 25 2013 MiTek Industries, Inc. Wed Feb 11 15:05:09 2015 Page 1 Timberland Lumber Company, Indianapolis, IN 46222
ID:6wSYySsChxEClNJ8ETXMjTzZ3cH-npEAX5Zyjh_Ze_VfZOOZcKDWF1PyFvE1aKGvCGzmAbu
Scale = 1:73.0
Sheet Front
Full Sheathing
1 Ply 1/2 x 4 x 8 Duramate
12
3
4
5 6 7
8
9
10
11
12
13
14
15 16
17
18
19
20
21
22
2324 25
26
27
28
29
52 51 50 49 48 47 46 45 44 43 42 41 40 39 38 37 36 35 34 33 32 31 30
53 54
3x6
5x6
3x6
3x6 3x6
5x6 5x6
36-0-0
36-0-0
-0-11-4
0-11-4
18-0-0
18-0-0
36-0-0
18-0-0
36-11-4
0-11-4
0-6-611-0-60-6-67.00 12
Plate Offsets (X,Y): [2:0-2-8,0-0-12], [28:0-2-8,0-0-12], [38:0-3-0,0-3-0], [44:0-3-0,0-3-0]
LOADING (psf)
TCLL
(Roof Snow=20.0)
TCDL
BCLL
BCDL
20.0
10.0
0.0
10.0
SPACING
Plates Increase
Lumber Increase
Rep Stress Incr
Code
2-0-0
1.15
1.15
NO
IRC2006/TPI2002
CSI
TC
BC
WB
(Matrix)
0.13
0.10
0.11
DEFL
Vert(LL)
Vert(TL)
Horz(TL)
in
0.00
0.00
0.01
(loc)
29
29
28
l/defl
n/r
n/r
n/a
L/d
120
120
n/a
PLATES
MT20
Weight: 250 lb FT = 0%
GRIP
197/144
LUMBER
TOP CHORD 2x4 SPF No.2
BOT CHORD 2x4 SPF No.2
OTHERS 2x4 SPF Stud/No.3 *Except*
15-41,14-42,13-43,12-44,16-40,17-39,18-38: 2x4 SPF No.2
WEDGE
Left: 2x4 SPF Stud/No.3, Right: 2x4 SPF Stud/No.3
BRACING
TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins.
BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing.
WEBS 1 Row at midpt 15-41, 14-42, 13-43, 12-44, 16-40, 17-39,
18-38
MiTek recommends that Stabilizers and required cross bracing
be installed during truss erection, in accordance with Stabilizer
Installation guide.
REACTIONS All bearings 36-0-0.
(lb) - Max Uplift All uplift 100 lb or less at joint(s) 43, 44, 45, 46, 47, 48, 49, 50, 51,
52, 39, 38, 37, 36, 35, 34, 33, 32, 31, 30
Max Grav All reactions 250 lb or less at joint(s) 2, 28, 41, 42, 43, 44, 45, 46, 47,
48, 49, 50, 51, 40, 39, 38, 37, 36, 35, 34, 33, 32, 31 except 52=257(LC 1),
30=257(LC 1)
FORCES (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
NOTES
1) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=30ft; Cat. II; Exp B; enclosed; C-C Exterior(2); cantilever left and right
exposed ; end vertical left and right exposed; Lumber DOL=1.33 plate grip DOL=1.33
2) Truss designed for wind loads in the plane of the truss only. For studs exposed to wind (normal to the face), see Standard Industry
Gable End Details as applicable, or consult qualified building designer as per ANSI/TPI 1.
3) TCLL: ASCE 7-05; Pf=20.0 psf (flat roof snow); Category II; Exp B; Fully Exp.; Ct=1.1
4) Unbalanced snow loads have been considered for this design.
5) This truss has been designed for greater of min roof live load of 16.0 psf or 2.00 times flat roof load of 20.0 psf on overhangs
non-concurrent with other live loads.
6) This truss has been designed for basic load combinations, which include cases with reductions for multiple concurrent live loads.
7) All plates are 2x4 MT20 unless otherwise indicated.
8) Gable requires continuous bottom chord bearing.
9) Gable studs spaced at 1-4-0 oc.
10) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
11) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 43, 44, 45, 46, 47,
48, 49, 50, 51, 52, 39, 38, 37, 36, 35, 34, 33, 32, 31, 30.
12) "Semi-rigid pitchbreaks including heels" Member end fixity model was used in the analysis and design of this truss.
13) Warning: Additional permanent and stability bracing for truss system (not part of this component design) is always required.
LOAD CASE(S) Standard
Design valid for use only with MiTek connectors. This design is based only upon parameters shown, and is for an individual building component. Applicability of design parameters and proper incorporation of component is responsibility of building designer - not truss designer. Bracing shown is for lateral support of individual web members only. Additional temporary bracing to insure stability during construction is the responsibillity of theerector. Additional permanent bracing of the overall structure is the responsibility of the building designer. For general guidance regardingfabrication, quality control, storage, delivery, erection and bracing, consult 14515 N. Outer Forty, Suite #300
Chesterfield, MO 63017
ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 781 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information
February 12,2015
Job
1500058
Truss
C
Truss Type
COMMON
Qty
5
Ply
1
SOUTHILL C STANDARD
Job Reference (optional)
I23659117
7.430 s Jul 25 2013 MiTek Industries, Inc. Wed Feb 11 15:05:10 2015 Page 1 Timberland Lumber Company, Indianapolis, IN 46222
ID:6wSYySsChxEClNJ8ETXMjTzZ3cH-F?oYkRaaU?6QF74r75vo9XlZQRd3_KFBp_?SkizmAbt
Scale = 1:56.6
1 2
3
4
5
6
7
8 9
12 11 10
13 14
3x6
4x6
3x6
4x6 3x4 3x4
2x4
3x4
2x4
4x6
10-0-3
10-0-3
17-11-13
7-11-10
28-0-0
10-0-3
-0-11-4
0-11-4
7-1-0
7-1-0
14-0-0
6-11-0
20-11-0
6-11-0
28-0-0
7-1-0
28-11-4
0-11-4
0-6-68-8-60-6-67.00 12
Plate Offsets (X,Y): [2:0-2-14,0-0-14], [8:0-2-14,0-0-14]
LOADING (psf)
TCLL
(Roof Snow=20.0)
TCDL
BCLL
BCDL
20.0
10.0
0.0
10.0
SPACING
Plates Increase
Lumber Increase
Rep Stress Incr
Code
2-0-0
1.15
1.15
YES
IRC2006/TPI2002
CSI
TC
BC
WB
(Matrix)
0.61
0.62
0.25
DEFL
Vert(LL)
Vert(TL)
Horz(TL)
in
-0.25
-0.68
0.06
(loc)
2-12
2-12
8
l/defl
>999
>493
n/a
L/d
240
180
n/a
PLATES
MT20
Weight: 105 lb FT = 0%
GRIP
169/123
LUMBER
TOP CHORD 2x4 SPF No.2
BOT CHORD 2x4 SPF-S 1650F 1.6E
WEBS 2x4 SPF No.2 *Except*
7-10,3-12: 2x4 SPF Stud/No.3
WEDGE
Left: 2x4 SPF Stud/No.3, Right: 2x4 SPF Stud/No.3
BRACING
TOP CHORD Structural wood sheathing directly applied or 3-10-9 oc purlins.
BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing.
MiTek recommends that Stabilizers and required cross bracing
be installed during truss erection, in accordance with Stabilizer
Installation guide.
REACTIONS (lb/size)2=1173/0-3-8 (min. 0-1-11), 8=1173/0-3-8 (min. 0-1-11)
Max Uplift2=-106(LC 6), 8=-106(LC 6)
FORCES (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
TOP CHORD 2-3=-1685/161, 3-5=-1464/192, 5-7=-1464/192, 7-8=-1685/161
BOT CHORD 2-12=-43/1371, 10-12=0/926, 8-10=-43/1371
WEBS 5-10=-37/588, 7-10=-413/174, 5-12=-37/588, 3-12=-413/174
NOTES
1) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=30ft; Cat. II; Exp B; enclosed; C-C Exterior(2); cantilever left and right
exposed ; end vertical left and right exposed; Lumber DOL=1.33 plate grip DOL=1.33
2) TCLL: ASCE 7-05; Pf=20.0 psf (flat roof snow); Category II; Exp B; Fully Exp.; Ct=1.1
3) Unbalanced snow loads have been considered for this design.
4) This truss has been designed for greater of min roof live load of 16.0 psf or 2.00 times flat roof load of 20.0 psf on overhangs
non-concurrent with other live loads.
5) This truss has been designed for basic load combinations, which include cases with reductions for multiple concurrent live loads.
6) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) except (jt=lb) 2=106,
8=106.
8) "Semi-rigid pitchbreaks including heels" Member end fixity model was used in the analysis and design of this truss.
9) Warning: Additional permanent and stability bracing for truss system (not part of this component design) is always required.
LOAD CASE(S) Standard
Design valid for use only with MiTek connectors. This design is based only upon parameters shown, and is for an individual building component. Applicability of design parameters and proper incorporation of component is responsibility of building designer - not truss designer. Bracing shown is for lateral support of individual web members only. Additional temporary bracing to insure stability during construction is the responsibillity of theerector. Additional permanent bracing of the overall structure is the responsibility of the building designer. For general guidance regardingfabrication, quality control, storage, delivery, erection and bracing, consult 14515 N. Outer Forty, Suite #300
Chesterfield, MO 63017
ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 781 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information
February 12,2015
Job
1500058
Truss
C1
Truss Type
COMMON
Qty
4
Ply
1
SOUTHILL C STANDARD
Job Reference (optional)
I23659118
7.430 s Jul 25 2013 MiTek Industries, Inc. Wed Feb 11 15:05:11 2015 Page 1 Timberland Lumber Company, Indianapolis, IN 46222
ID:6wSYySsChxEClNJ8ETXMjTzZ3cH-jBMwxnbDFJEHtHf1goQ1hlIgHry3jnSK1el0G9zmAbs
Scale = 1:56.1
1 2
3 4
5
6
7
8
11 10 9
12 133x8
4x6
3x4
4x6 3x4 3x4
2x4
3x4
2x4
4x6
10-0-3
10-0-3
17-11-13
7-11-10
28-0-0
10-0-3
-0-11-4
0-11-4
7-1-0
7-1-0
14-0-0
6-11-0
20-11-0
6-11-0
28-0-0
7-1-0
0-6-68-8-60-6-67.00 12
Plate Offsets (X,Y): [2:0-2-12,0-0-12], [4:0-4-0,Edge], [8:0-2-12,0-0-12]
LOADING (psf)
TCLL
(Roof Snow=20.0)
TCDL
BCLL
BCDL
20.0
10.0
0.0
10.0
SPACING
Plates Increase
Lumber Increase
Rep Stress Incr
Code
2-0-0
1.15
1.15
YES
IRC2006/TPI2002
CSI
TC
BC
WB
(Matrix)
0.86
0.63
0.25
DEFL
Vert(LL)
Vert(TL)
Horz(TL)
in
-0.26
-0.71
0.06
(loc)
8-9
8-9
8
l/defl
>999
>471
n/a
L/d
240
180
n/a
PLATES
MT20
Weight: 103 lb FT = 0%
GRIP
169/123
LUMBER
TOP CHORD 2x4 SPF No.2
BOT CHORD 2x4 SPF-S 1650F 1.6E
WEBS 2x4 SPF No.2 *Except*
7-9,3-11: 2x4 SPF Stud/No.3
WEDGE
Left: 2x4 SPF Stud/No.3, Right: 2x4 SPF Stud/No.3
BRACING
TOP CHORD Structural wood sheathing directly applied or 2-2-0 oc purlins.
BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing.
MiTek recommends that Stabilizers and required cross bracing
be installed during truss erection, in accordance with Stabilizer
Installation guide.
REACTIONS (lb/size)2=1175/0-3-8 (min. 0-1-11), 8=1107/0-3-8 (min. 0-1-9)
Max Horz 2=15(LC 6)
Max Uplift2=-107(LC 6), 8=-70(LC 6)
FORCES (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
TOP CHORD 2-3=-1687/163, 3-5=-1466/193, 5-7=-1470/195, 7-8=-1691/165
BOT CHORD 2-11=-59/1373, 9-11=0/928, 8-9=-64/1379
WEBS 5-9=-40/594, 7-9=-417/180, 5-11=-38/582, 3-11=-407/174
NOTES
1) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=30ft; Cat. II; Exp B; enclosed; C-C Exterior(2); cantilever left and right
exposed ; end vertical left and right exposed; Lumber DOL=1.33 plate grip DOL=1.33
2) TCLL: ASCE 7-05; Pf=20.0 psf (flat roof snow); Category II; Exp B; Fully Exp.; Ct=1.1
3) Unbalanced snow loads have been considered for this design.
4) This truss has been designed for greater of min roof live load of 16.0 psf or 2.00 times flat roof load of 20.0 psf on overhangs
non-concurrent with other live loads.
5) This truss has been designed for basic load combinations, which include cases with reductions for multiple concurrent live loads.
6) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 8 except (jt=lb)
2=107.
8) "Semi-rigid pitchbreaks including heels" Member end fixity model was used in the analysis and design of this truss.
9) Warning: Additional permanent and stability bracing for truss system (not part of this component design) is always required.
LOAD CASE(S) Standard
Design valid for use only with MiTek connectors. This design is based only upon parameters shown, and is for an individual building component. Applicability of design parameters and proper incorporation of component is responsibility of building designer - not truss designer. Bracing shown is for lateral support of individual web members only. Additional temporary bracing to insure stability during construction is the responsibillity of theerector. Additional permanent bracing of the overall structure is the responsibility of the building designer. For general guidance regardingfabrication, quality control, storage, delivery, erection and bracing, consult 14515 N. Outer Forty, Suite #300
Chesterfield, MO 63017
ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 781 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information
February 12,2015
Job
1500058
Truss
CG
Truss Type
GABLE
Qty
1
Ply
1
SOUTHILL C STANDARD
Job Reference (optional)
I23659119
7.430 s Jul 25 2013 MiTek Industries, Inc. Wed Feb 11 15:05:12 2015 Page 1 Timberland Lumber Company, Indianapolis, IN 46222
ID:6wSYySsChxEClNJ8ETXMjTzZ3cH-BNwI97cr0cM7VREEEWxGEyr0VFQfSFHTGIUZobzmAbr
Scale = 1:56.9
Sheet Front
Full Sheathing
1 Ply 1/2 x 4 x 8 Duramate
1 2
3
4
5 6
7
8
9
10
11
12
13
14
15
16
17
18 19
20
21
22
23
40 39 38 37 36 35 34 33 32 31 30 29 28 27 26 25 24
3x4
4x6
3x4
3x4
3x8
3x4
3x8 4x6
28-0-0
28-0-0
-0-11-4
0-11-4
14-0-0
14-0-0
28-0-0
14-0-0
28-11-4
0-11-4
0-6-68-8-60-6-67.00 12
Plate Offsets (X,Y): [2:0-0-0,0-0-11], [2:0-2-5,Edge], [22:0-0-0,0-0-11], [22:0-2-5,Edge], [32:Edge,0-2-0]
LOADING (psf)
TCLL
(Roof Snow=20.0)
TCDL
BCLL
BCDL
20.0
10.0
0.0
10.0
SPACING
Plates Increase
Lumber Increase
Rep Stress Incr
Code
2-0-0
1.15
1.15
NO
IRC2006/TPI2002
CSI
TC
BC
WB
(Matrix)
0.13
0.10
0.15
DEFL
Vert(LL)
Vert(TL)
Horz(TL)
in
0.00
0.00
0.00
(loc)
23
23
22
l/defl
n/r
n/r
n/a
L/d
120
120
n/a
PLATES
MT20
Weight: 167 lb FT = 0%
GRIP
197/144
LUMBER
TOP CHORD 2x4 SPF No.2
BOT CHORD 2x4 SPF No.2
OTHERS 2x4 SPF Stud/No.3 *Except*
12-32: 2x4 SPF No.2
WEDGE
Left: 2x4 SPF Stud/No.3, Right: 2x4 SPF Stud/No.3
BRACING
TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins.
BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing.
WEBS 1 Row at midpt 12-32
MiTek recommends that Stabilizers and required cross bracing
be installed during truss erection, in accordance with Stabilizer
Installation guide.
REACTIONS All bearings 28-0-0.
(lb) - Max Uplift All uplift 100 lb or less at joint(s) 2, 22, 33, 34, 35, 36, 37, 38, 39, 40,
31, 30, 29, 28, 27, 26, 25, 24
Max Grav All reactions 250 lb or less at joint(s) 2, 22, 32, 33, 34, 35, 36, 37, 38,
39, 31, 30, 29, 28, 27, 26, 25 except 40=257(LC 1), 24=257(LC 1)
FORCES (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
NOTES
1) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=30ft; Cat. II; Exp B; enclosed; C-C Exterior(2); cantilever left and right
exposed ; end vertical left and right exposed; Lumber DOL=1.33 plate grip DOL=1.33
2) Truss designed for wind loads in the plane of the truss only. For studs exposed to wind (normal to the face), see Standard Industry
Gable End Details as applicable, or consult qualified building designer as per ANSI/TPI 1.
3) TCLL: ASCE 7-05; Pf=20.0 psf (flat roof snow); Category II; Exp B; Fully Exp.; Ct=1.1
4) Unbalanced snow loads have been considered for this design.
5) This truss has been designed for greater of min roof live load of 16.0 psf or 2.00 times flat roof load of 20.0 psf on overhangs
non-concurrent with other live loads.
6) This truss has been designed for basic load combinations, which include cases with reductions for multiple concurrent live loads.
7) All plates are 2x4 MT20 unless otherwise indicated.
8) Gable requires continuous bottom chord bearing.
9) Gable studs spaced at 1-4-0 oc.
10) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
11) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 2, 22, 33, 34, 35, 36,
37, 38, 39, 40, 31, 30, 29, 28, 27, 26, 25, 24.
12) "Semi-rigid pitchbreaks including heels" Member end fixity model was used in the analysis and design of this truss.
13) Warning: Additional permanent and stability bracing for truss system (not part of this component design) is always required.
LOAD CASE(S) Standard
Design valid for use only with MiTek connectors. This design is based only upon parameters shown, and is for an individual building component. Applicability of design parameters and proper incorporation of component is responsibility of building designer - not truss designer. Bracing shown is for lateral support of individual web members only. Additional temporary bracing to insure stability during construction is the responsibillity of theerector. Additional permanent bracing of the overall structure is the responsibility of the building designer. For general guidance regardingfabrication, quality control, storage, delivery, erection and bracing, consult 14515 N. Outer Forty, Suite #300
Chesterfield, MO 63017
ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 781 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information
February 12,2015
Job
1500058
Truss
E
Truss Type
HIP
Qty
3
Ply
1
SOUTHILL C STANDARD
Job Reference (optional)
I23659120
7.430 s Jul 25 2013 MiTek Industries, Inc. Wed Feb 11 15:05:13 2015 Page 1 Timberland Lumber Company, Indianapolis, IN 46222
ID:6wSYySsChxEClNJ8ETXMjTzZ3cH-faTgMTcTnwU_6bpQoDSVmAN6zffTBWldVyE6L1zmAbq
Scale = 1:66.4
1
2
3
4 5
6
7
8
13 12 11 10 9
14
15
16 17
18
19
4x6 4x6
3x4 3x4
3x6
3x4
3x6
2x8
3x6 3x6
2x8
8-1-11
8-1-11
12-10-5
4-8-9
21-0-0
8-1-11
-1-3-4
1-3-4
3-8-11
3-8-11
8-1-11
4-5-1
12-10-5
4-8-9
17-3-5
4-5-1
21-0-0
3-8-11
22-3-4
1-3-4
1-6-011-0-01-6-011-0-014.00 12
Plate Offsets (X,Y): [3:0-1-9,0-1-7], [4:0-3-2,0-2-0], [5:0-3-2,0-2-0], [6:0-1-9,0-1-7]
LOADING (psf)
TCLL
(Roof Snow=20.0)
TCDL
BCLL
BCDL
20.0
10.0
0.0
10.0
SPACING
Plates Increase
Lumber Increase
Rep Stress Incr
Code
2-0-0
1.15
1.15
YES
IRC2006/TPI2002
CSI
TC
BC
WB
(Matrix)
0.47
0.57
0.90
DEFL
Vert(LL)
Vert(TL)
Horz(TL)
in
-0.21
-0.38
0.03
(loc)
12-13
12-13
9
l/defl
>999
>660
n/a
L/d
240
180
n/a
PLATES
MT20
Weight: 118 lb FT = 0%
GRIP
197/144
LUMBER
TOP CHORD 2x4 SPF No.2
BOT CHORD 2x4 SPF No.2
WEBS 2x4 SPF Stud/No.3 *Except*
4-12,5-11: 2x4 SPF No.2
BRACING
TOP CHORD Structural wood sheathing directly applied or 5-5-15 oc purlins, except
end verticals, and 2-0-0 oc purlins (6-0-0 max.): 4-5.
BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing.
MiTek recommends that Stabilizers and required cross bracing
be installed during truss erection, in accordance with Stabilizer
Installation guide.
REACTIONS (lb/size)13=913/0-3-8 (min. 0-2-4), 9=913/0-3-8 (min. 0-2-4)
Max Uplift13=-103(LC 6), 9=-103(LC 6)
Max Grav 13=1418(LC 16), 9=1418(LC 16)
FORCES (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
TOP CHORD 2-3=-285/137, 3-4=-1066/189, 4-5=-541/180, 5-6=-1066/189, 6-7=-285/137,
2-13=-422/162, 7-9=-422/162
BOT CHORD 12-13=0/684, 11-12=0/541, 9-11=0/684
WEBS 4-12=-49/296, 5-11=-49/296, 3-13=-1092/0, 6-9=-1092/0
NOTES
1) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=30ft; Cat. II; Exp B; enclosed; C-C Exterior(2); cantilever left and right
exposed ; end vertical left and right exposed; Lumber DOL=1.33 plate grip DOL=1.33
2) TCLL: ASCE 7-05; Pf=20.0 psf (flat roof snow); Category II; Exp B; Fully Exp.; Ct=1.1, Lu=50-0-0
3) Unbalanced snow loads have been considered for this design.
4) This truss has been designed for greater of min roof live load of 12.0 psf or 2.00 times flat roof load of 20.0 psf on overhangs
non-concurrent with other live loads.
5) This truss has been designed for basic load combinations, which include cases with reductions for multiple concurrent live loads.
6) Provide adequate drainage to prevent water ponding.
7) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
8) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) except (jt=lb) 13=103,
9=103.
9) "Semi-rigid pitchbreaks including heels" Member end fixity model was used in the analysis and design of this truss.
10) Graphical purlin representation does not depict the size or the orientation of the purlin along the top and/or bottom chord.
11) Warning: Additional permanent and stability bracing for truss system (not part of this component design) is always required.
LOAD CASE(S) Standard
TRUSS IS NOT DESIGNED TO SUPPORT ANY ADDITIONAL LOADS ON PANEL 11-12
Design valid for use only with MiTek connectors. This design is based only upon parameters shown, and is for an individual building component. Applicability of design parameters and proper incorporation of component is responsibility of building designer - not truss designer. Bracing shown is for lateral support of individual web members only. Additional temporary bracing to insure stability during construction is the responsibillity of theerector. Additional permanent bracing of the overall structure is the responsibility of the building designer. For general guidance regardingfabrication, quality control, storage, delivery, erection and bracing, consult 14515 N. Outer Forty, Suite #300
Chesterfield, MO 63017
ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 781 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information
February 12,2015
Job
1500058
Truss
E1
Truss Type
HIP
Qty
6
Ply
1
SOUTHILL C STANDARD
Job Reference (optional)
I23659121
7.430 s Jul 25 2013 MiTek Industries, Inc. Wed Feb 11 15:05:13 2015 Page 1 Timberland Lumber Company, Indianapolis, IN 46222
ID:6wSYySsChxEClNJ8ETXMjTzZ3cH-faTgMTcTnwU_6bpQoDSVmAN4GfejBY?dVyE6L1zmAbq
Scale: 3/16"=1’
1
2
3 4
5
6
7
12 11 10 9 8
13
14
15
16
2x4
4x6 4x6
3x6 3x4 3x4
4x6 3x4
3x6
2x8
3x4
7-1-3
7-1-3
11-9-13
4-8-9
19-11-8
8-1-11
2-8-1
2-8-1
7-1-3
4-5-2
11-9-13
4-8-9
16-2-13
4-5-1
19-11-8
3-8-11
21-2-12
1-3-4
2-8-911-0-01-6-011-0-014.00 12
Plate Offsets (X,Y): [3:0-3-2,0-2-0], [4:0-3-2,0-2-0]
LOADING (psf)
TCLL
(Roof Snow=20.0)
TCDL
BCLL
BCDL
20.0
10.0
0.0
10.0
SPACING
Plates Increase
Lumber Increase
Rep Stress Incr
Code
2-0-0
1.15
1.15
YES
IRC2006/TPI2002
CSI
TC
BC
WB
(Matrix)
0.64
0.62
0.82
DEFL
Vert(LL)
Vert(TL)
Horz(TL)
in
-0.21
-0.46
0.02
(loc)
8-10
8-10
8
l/defl
>999
>514
n/a
L/d
240
180
n/a
PLATES
MT20
Weight: 114 lb FT = 0%
GRIP
197/144
LUMBER
TOP CHORD 2x4 SPF No.2
BOT CHORD 2x4 SPF No.2
WEBS 2x4 SPF Stud/No.3 *Except*
3-11,4-10: 2x4 SPF No.2
BRACING
TOP CHORD Structural wood sheathing directly applied or 5-6-4 oc purlins, except
end verticals, and 2-0-0 oc purlins (6-0-0 max.): 3-4.
BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing.
MiTek recommends that Stabilizers and required cross bracing
be installed during truss erection, in accordance with Stabilizer
Installation guide.
REACTIONS (lb/size)8=875/0-3-8 (min. 0-2-2), 12=784/0-3-8 (min. 0-1-14)
Max Horz 12=-77(LC 6)
Max Uplift8=-102(LC 6), 12=-58(LC 6)
Max Grav 8=1357(LC 16), 12=1203(LC 16)
FORCES (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
TOP CHORD 2-3=-965/188, 3-4=-481/181, 4-5=-986/188, 5-6=-297/139, 6-8=-428/164
BOT CHORD 11-12=0/492, 10-11=0/481, 8-10=0/642
WEBS 4-10=-48/263, 5-10=-251/170, 5-8=-995/0, 2-12=-1151/46
NOTES
1) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=30ft; Cat. II; Exp B; enclosed; C-C Exterior(2); cantilever left and right
exposed ; end vertical left and right exposed; Lumber DOL=1.33 plate grip DOL=1.33
2) TCLL: ASCE 7-05; Pf=20.0 psf (flat roof snow); Category II; Exp B; Fully Exp.; Ct=1.1, Lu=50-0-0
3) Unbalanced snow loads have been considered for this design.
4) This truss has been designed for greater of min roof live load of 12.0 psf or 2.00 times flat roof load of 20.0 psf on overhangs
non-concurrent with other live loads.
5) This truss has been designed for basic load combinations, which include cases with reductions for multiple concurrent live loads.
6) Provide adequate drainage to prevent water ponding.
7) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
8) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 12 except (jt=lb)
8=102.
9) "Semi-rigid pitchbreaks including heels" Member end fixity model was used in the analysis and design of this truss.
10) Graphical purlin representation does not depict the size or the orientation of the purlin along the top and/or bottom chord.
11) Warning: Additional permanent and stability bracing for truss system (not part of this component design) is always required.
LOAD CASE(S) Standard
TRUSS IS NOT DESIGNED TO SUPPORT ANY ADDITIONAL LOADS ON PANEL 10-11
Design valid for use only with MiTek connectors. This design is based only upon parameters shown, and is for an individual building component. Applicability of design parameters and proper incorporation of component is responsibility of building designer - not truss designer. Bracing shown is for lateral support of individual web members only. Additional temporary bracing to insure stability during construction is the responsibillity of theerector. Additional permanent bracing of the overall structure is the responsibility of the building designer. For general guidance regardingfabrication, quality control, storage, delivery, erection and bracing, consult 14515 N. Outer Forty, Suite #300
Chesterfield, MO 63017
ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 781 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information
February 12,2015
Job
1500058
Truss
E2
Truss Type
SPECIAL
Qty
1
Ply
1
SOUTHILL C STANDARD
Job Reference (optional)
I23659122
7.430 s Jul 25 2013 MiTek Industries, Inc. Wed Feb 11 15:05:14 2015 Page 1 Timberland Lumber Company, Indianapolis, IN 46222
ID:6wSYySsChxEClNJ8ETXMjTzZ3cH-7m13apd5XEcrklOcMx_kJNwAL2?cw_rmkczgtTzmAbp
Scale = 1:54.8
1
2
3
4
5
6
7
8
14 13 12 11 10 9
15
16
17
18
19
20
5x6 6x6
4x6
3x4 4x9
2x8
2x4
5x6
3x4 3x4
3x4
3x4
4-1-0
4-1-0
8-4-12
4-3-12
14-8-4
6-3-8
21-0-0
6-3-12
-1-3-4
1-3-4
6-2-14
6-2-14
10-6-10
4-3-12
14-9-12
4-3-2
21-0-0
6-2-4
22-3-4
1-3-4
1-6-03-7-18-8-101-6-03-7-114.00 12
Plate Offsets (X,Y): [3:0-3-15,0-2-4], [5:0-3-9,0-2-4], [6:Edge,0-1-14], [7:0-1-13,0-3-0], [13:0-1-12,0-1-8]
LOADING (psf)
TCLL
(Roof Snow=20.0)
TCDL
BCLL
BCDL
20.0
10.0
0.0
10.0
SPACING
Plates Increase
Lumber Increase
Rep Stress Incr
Code
2-0-0
1.15
1.15
NO
IRC2006/TPI2002
CSI
TC
BC
WB
(Matrix)
0.94
0.51
0.85
DEFL
Vert(LL)
Vert(TL)
Horz(TL)
in
-0.07
-0.17
0.04
(loc)
10-11
10-11
9
l/defl
>999
>999
n/a
L/d
240
180
n/a
PLATES
MT20
Weight: 106 lb FT = 0%
GRIP
197/144
LUMBER
TOP CHORD 2x4 SPF No.2
BOT CHORD 2x4 SPF No.2
WEBS 2x4 SPF Stud/No.3
BRACING
TOP CHORD Structural wood sheathing directly applied or 5-4-1 oc purlins, except
end verticals, and 2-0-0 oc purlins (4-0-7 max.): 3-5.
BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing.
MiTek recommends that Stabilizers and required cross bracing
be installed during truss erection, in accordance with Stabilizer
Installation guide.
REACTIONS (lb/size)9=913/0-3-8 (min. 0-1-8), 14=913/0-3-8 (min. 0-1-13)
Max Uplift9=-103(LC 6), 14=-113(LC 6)
Max Grav 9=913(LC 1), 14=1159(LC 17)
FORCES (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
TOP CHORD 3-4=-1091/103, 4-5=-1602/135, 5-6=-947/141, 6-7=-821/123, 2-14=-339/170,
7-9=-857/134
BOT CHORD 13-14=0/572, 11-13=0/1562, 10-11=0/1567
WEBS 5-10=-1405/195, 7-10=0/411, 3-14=-1145/0, 3-13=-29/950, 4-13=-866/84, 4-11=0/372,
6-10=-81/939
NOTES
1) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=30ft; Cat. II; Exp B; enclosed; C-C Exterior(2); cantilever left and right
exposed ; end vertical left and right exposed; Lumber DOL=1.33 plate grip DOL=1.33
2) TCLL: ASCE 7-05; Pf=20.0 psf (flat roof snow); Category II; Exp B; Fully Exp.; Ct=1.1, Lu=50-0-0
3) Unbalanced snow loads have been considered for this design.
4) This truss has been designed for greater of min roof live load of 12.0 psf or 2.00 times flat roof load of 20.0 psf on overhangs
non-concurrent with other live loads.
5) This truss has been designed for basic load combinations, which include cases with reductions for multiple concurrent live loads.
6) Provide adequate drainage to prevent water ponding.
7) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
8) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) except (jt=lb) 9=103,
14=113.
9) "Semi-rigid pitchbreaks including heels" Member end fixity model was used in the analysis and design of this truss.
10) Graphical purlin representation does not depict the size or the orientation of the purlin along the top and/or bottom chord.
11) Warning: Additional permanent and stability bracing for truss system (not part of this component design) is always required.
LOAD CASE(S) Standard
Design valid for use only with MiTek connectors. This design is based only upon parameters shown, and is for an individual building component. Applicability of design parameters and proper incorporation of component is responsibility of building designer - not truss designer. Bracing shown is for lateral support of individual web members only. Additional temporary bracing to insure stability during construction is the responsibillity of theerector. Additional permanent bracing of the overall structure is the responsibility of the building designer. For general guidance regardingfabrication, quality control, storage, delivery, erection and bracing, consult 14515 N. Outer Forty, Suite #300
Chesterfield, MO 63017
ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 781 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information
February 12,2015
Job
1500058
Truss
E3
Truss Type
SPECIAL
Qty
1
Ply
1
SOUTHILL C STANDARD
Job Reference (optional)
I23659123
7.430 s Jul 25 2013 MiTek Industries, Inc. Wed Feb 11 15:05:15 2015 Page 1 Timberland Lumber Company, Indianapolis, IN 46222
ID:6wSYySsChxEClNJ8ETXMjTzZ3cH-bybRn9ejIXkiMvypveVzsbTLGSOGfR9wyGjDPwzmAbo
Scale = 1:54.8
1
2
3
4 5
6
7
8
14 13 12 11 10 9
15
16 17
18
19
5x6 5x6
4x6
3x4 4x9
2x4
2x4
5x6
3x4 3x4
3x4
3x4
5-6-3
5-6-3
9-9-15
4-3-12
15-3-3
5-5-5
21-0-0
5-8-13
-1-3-4
1-3-4
3-4-5
3-4-5
7-8-1
4-3-12
11-11-13
4-3-12
14-9-12
2-9-15
21-0-0
6-2-4
22-3-4
1-3-4
1-6-05-3-18-8-101-6-05-3-114.00 12
Plate Offsets (X,Y): [3:0-3-15,0-2-4], [5:0-3-0,0-2-4], [6:Edge,0-1-14], [7:Edge,0-3-4]
LOADING (psf)
TCLL
(Roof Snow=20.0)
TCDL
BCLL
BCDL
20.0
10.0
0.0
10.0
SPACING
Plates Increase
Lumber Increase
Rep Stress Incr
Code
2-0-0
1.15
1.15
NO
IRC2006/TPI2002
CSI
TC
BC
WB
(Matrix)
0.93
0.36
0.85
DEFL
Vert(LL)
Vert(TL)
Horz(TL)
in
-0.05
-0.11
0.03
(loc)
11
10-11
9
l/defl
>999
>999
n/a
L/d
240
180
n/a
PLATES
MT20
Weight: 115 lb FT = 0%
GRIP
197/144
LUMBER
TOP CHORD 2x4 SPF No.2
BOT CHORD 2x4 SPF No.2
WEBS 2x4 SPF Stud/No.3
BRACING
TOP CHORD Structural wood sheathing directly applied or 5-9-4 oc purlins, except
end verticals, and 2-0-0 oc purlins (4-9-14 max.): 3-5.
BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing.
MiTek recommends that Stabilizers and required cross bracing
be installed during truss erection, in accordance with Stabilizer
Installation guide.
REACTIONS (lb/size)9=913/0-3-8 (min. 0-1-8), 14=913/0-3-8 (min. 0-1-12)
Max Uplift9=-105(LC 6), 14=-111(LC 6)
Max Grav 9=913(LC 1), 14=1103(LC 17)
FORCES (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
TOP CHORD 2-3=-256/189, 3-4=-921/119, 4-5=-1142/133, 5-6=-726/155, 6-7=-843/127,
2-14=-475/211, 7-9=-861/133
BOT CHORD 13-14=0/622, 11-13=0/1173, 10-11=0/1066
WEBS 6-10=-109/970, 7-10=0/427, 3-14=-1059/0, 3-13=-6/747, 4-13=-642/71, 5-10=-1134/163
NOTES
1) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=30ft; Cat. II; Exp B; enclosed; C-C Exterior(2); cantilever left and right
exposed ; end vertical left and right exposed; Lumber DOL=1.33 plate grip DOL=1.33
2) TCLL: ASCE 7-05; Pf=20.0 psf (flat roof snow); Category II; Exp B; Fully Exp.; Ct=1.1, Lu=50-0-0
3) Unbalanced snow loads have been considered for this design.
4) This truss has been designed for greater of min roof live load of 12.0 psf or 2.00 times flat roof load of 20.0 psf on overhangs
non-concurrent with other live loads.
5) This truss has been designed for basic load combinations, which include cases with reductions for multiple concurrent live loads.
6) Provide adequate drainage to prevent water ponding.
7) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
8) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) except (jt=lb) 9=105,
14=111.
9) "Semi-rigid pitchbreaks including heels" Member end fixity model was used in the analysis and design of this truss.
10) Graphical purlin representation does not depict the size or the orientation of the purlin along the top and/or bottom chord.
11) Warning: Additional permanent and stability bracing for truss system (not part of this component design) is always required.
LOAD CASE(S) Standard
Design valid for use only with MiTek connectors. This design is based only upon parameters shown, and is for an individual building component. Applicability of design parameters and proper incorporation of component is responsibility of building designer - not truss designer. Bracing shown is for lateral support of individual web members only. Additional temporary bracing to insure stability during construction is the responsibillity of theerector. Additional permanent bracing of the overall structure is the responsibility of the building designer. For general guidance regardingfabrication, quality control, storage, delivery, erection and bracing, consult 14515 N. Outer Forty, Suite #300
Chesterfield, MO 63017
ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 781 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information
February 12,2015
Job
1500058
Truss
E4
Truss Type
SPECIAL
Qty
1
Ply
1
SOUTHILL C STANDARD
Job Reference (optional)
I23659124
7.430 s Jul 25 2013 MiTek Industries, Inc. Wed Feb 11 15:05:16 2015 Page 1 Timberland Lumber Company, Indianapolis, IN 46222
ID:6wSYySsChxEClNJ8ETXMjTzZ3cH-499p?UfL3rsZz2X?TM0COo?XZshXOwC3BwSnyMzmAbn
Scale = 1:54.8
1
2
3
4
5
6
7
8
13 12 11 10 9
14
15 16
17
4x6 4x6
4x6
2x4 3x4 3x8
3x4
4x12
4x6
2x4
5x6
4-9-7
4-9-7
13-4-15
8-7-8
21-0-0
7-7-1
-1-3-4
1-3-4
4-9-7
4-9-7
9-1-3
4-3-12
13-4-15
4-3-12
14-9-12
1-4-13
21-0-0
6-2-4
22-3-4
1-3-4
1-6-06-11-18-8-101-6-06-11-114.00 12
Plate Offsets (X,Y): [2:0-2-8,0-1-8], [3:0-3-9,0-1-15], [7:Edge,0-3-4]
LOADING (psf)
TCLL
(Roof Snow=20.0)
TCDL
BCLL
BCDL
20.0
10.0
0.0
10.0
SPACING
Plates Increase
Lumber Increase
Rep Stress Incr
Code
2-0-0
1.15
1.15
NO
IRC2006/TPI2002
CSI
TC
BC
WB
(Matrix)
0.89
0.55
0.73
DEFL
Vert(LL)
Vert(TL)
Horz(TL)
in
-0.13
-0.34
0.02
(loc)
10-12
10-12
9
l/defl
>999
>729
n/a
L/d
240
180
n/a
PLATES
MT20
Weight: 118 lb FT = 0%
GRIP
197/144
LUMBER
TOP CHORD 2x4 SPF No.2
BOT CHORD 2x4 SPF No.2
WEBS 2x4 SPF Stud/No.3 *Except*
6-10: 2x4 SPF No.2
BRACING
TOP CHORD Structural wood sheathing directly applied or 5-3-15 oc purlins, except
end verticals, and 2-0-0 oc purlins (5-9-2 max.): 3-5.
BOT CHORD Rigid ceiling directly applied or 6-0-0 oc bracing.
WEBS 1 Row at midpt 5-10
MiTek recommends that Stabilizers and required cross bracing
be installed during truss erection, in accordance with Stabilizer
Installation guide.
REACTIONS (lb/size)13=913/0-3-8 (min. 0-1-13), 9=913/0-3-8 (min. 0-1-8)
Max Uplift13=-110(LC 6), 9=-106(LC 6)
Max Grav 13=1155(LC 18), 9=936(LC 17)
FORCES (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
TOP CHORD 2-3=-1019/113, 3-4=-623/128, 4-5=-787/131, 5-6=-1156/198, 6-7=-925/122,
2-13=-1131/122, 7-9=-875/141
BOT CHORD 10-12=0/928
WEBS 3-12=0/437, 4-12=-552/60, 4-10=-255/55, 5-10=-1093/168, 6-10=-142/1408, 2-12=0/633,
7-10=0/474
NOTES
1) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=30ft; Cat. II; Exp B; enclosed; C-C Exterior(2); cantilever left and right
exposed ; end vertical left and right exposed; Lumber DOL=1.33 plate grip DOL=1.33
2) TCLL: ASCE 7-05; Pf=20.0 psf (flat roof snow); Category II; Exp B; Fully Exp.; Ct=1.1, Lu=50-0-0
3) Unbalanced snow loads have been considered for this design.
4) This truss has been designed for greater of min roof live load of 12.0 psf or 2.00 times flat roof load of 20.0 psf on overhangs
non-concurrent with other live loads.
5) This truss has been designed for basic load combinations, which include cases with reductions for multiple concurrent live loads.
6) Provide adequate drainage to prevent water ponding.
7) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
8) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) except (jt=lb) 13=110,
9=106.
9) "Semi-rigid pitchbreaks including heels" Member end fixity model was used in the analysis and design of this truss.
10) Graphical purlin representation does not depict the size or the orientation of the purlin along the top and/or bottom chord.
11) Warning: Additional permanent and stability bracing for truss system (not part of this component design) is always required.
LOAD CASE(S) Standard
Design valid for use only with MiTek connectors. This design is based only upon parameters shown, and is for an individual building component. Applicability of design parameters and proper incorporation of component is responsibility of building designer - not truss designer. Bracing shown is for lateral support of individual web members only. Additional temporary bracing to insure stability during construction is the responsibillity of theerector. Additional permanent bracing of the overall structure is the responsibility of the building designer. For general guidance regardingfabrication, quality control, storage, delivery, erection and bracing, consult 14515 N. Outer Forty, Suite #300
Chesterfield, MO 63017
ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 781 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information
February 12,2015
Job
1500058
Truss
E5
Truss Type
HIP
Qty
1
Ply
1
SOUTHILL C STANDARD
Job Reference (optional)
I23659125
7.430 s Jul 25 2013 MiTek Industries, Inc. Wed Feb 11 15:05:16 2015 Page 1 Timberland Lumber Company, Indianapolis, IN 46222
ID:6wSYySsChxEClNJ8ETXMjTzZ3cH-499p?UfL3rsZz2X?TM0COo?VHsfMO2j3BwSnyMzmAbn
Scale = 1:52.4
1
2
3 4
5
6
11 10 9 8 7
12
13 14
15
6x8 6x8
2x8 3x6
3x6
4x9
3x6
4x9
2x8
6-2-9
6-2-9
14-9-7
8-6-14
21-0-0
6-2-9
-1-3-4
1-3-4
6-2-9
6-2-9
14-9-7
8-6-14
21-0-0
6-2-9
22-3-4
1-3-4
1-6-08-7-18-9-01-6-08-7-114.00 12
Plate Offsets (X,Y): [2:0-3-8,0-1-10], [3:0-2-3,0-2-7], [4:0-2-3,0-2-7], [5:0-3-8,0-1-10], [8:0-2-13,0-1-5], [10:0-2-13,0-1-5]
LOADING (psf)
TCLL
(Roof Snow=20.0)
TCDL
BCLL
BCDL
20.0
10.0
0.0
10.0
SPACING
Plates Increase
Lumber Increase
Rep Stress Incr
Code
2-0-0
1.15
1.15
YES
IRC2006/TPI2002
CSI
TC
BC
WB
(Matrix)
0.97
0.69
0.25
DEFL
Vert(LL)
Vert(TL)
Horz(TL)
in
-0.29
-0.30
0.01
(loc)
7-8
8
7
l/defl
>855
>819
n/a
L/d
240
180
n/a
PLATES
MT20
Weight: 107 lb FT = 0%
GRIP
197/144
LUMBER
TOP CHORD 2x4 SPF No.2 *Except*
3-4: 2x6 SP No.1
BOT CHORD 2x4 SPF No.2
WEBS 2x4 SPF Stud/No.3 *Except*
2-11,5-7: 2x6 SPF No.2
BRACING
TOP CHORD Structural wood sheathing directly applied or 4-7-14 oc purlins, except
end verticals, and 2-0-0 oc purlins (2-2-0 max.): 3-4.
BOT CHORD Rigid ceiling directly applied or 6-0-0 oc bracing.
MiTek recommends that Stabilizers and required cross bracing
be installed during truss erection, in accordance with Stabilizer
Installation guide.
REACTIONS (lb/size)11=912/0-3-8 (min. 0-2-0), 7=912/0-3-8 (min. 0-2-0)
Max Uplift11=-110(LC 6), 7=-110(LC 6)
Max Grav 11=1290(LC 16), 7=1290(LC 16)
FORCES (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
TOP CHORD 2-3=-1074/128, 3-4=-594/156, 4-5=-1074/128, 2-11=-1240/139, 5-7=-1240/139
BOT CHORD 8-10=0/594
WEBS 2-10=0/564, 3-10=0/251, 4-8=0/251, 5-8=0/564
NOTES
1) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=30ft; Cat. II; Exp B; enclosed; C-C Exterior(2); cantilever left and right
exposed ; end vertical left and right exposed; Lumber DOL=1.33 plate grip DOL=1.33
2) TCLL: ASCE 7-05; Pf=20.0 psf (flat roof snow); Category II; Exp B; Fully Exp.; Ct=1.1, Lu=50-0-0
3) Unbalanced snow loads have been considered for this design.
4) This truss has been designed for greater of min roof live load of 12.0 psf or 2.00 times flat roof load of 20.0 psf on overhangs
non-concurrent with other live loads.
5) This truss has been designed for basic load combinations, which include cases with reductions for multiple concurrent live loads.
6) Provide adequate drainage to prevent water ponding.
7) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
8) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) except (jt=lb) 11=110,
7=110.
9) "Semi-rigid pitchbreaks including heels" Member end fixity model was used in the analysis and design of this truss.
10) Graphical purlin representation does not depict the size or the orientation of the purlin along the top and/or bottom chord.
11) Warning: Additional permanent and stability bracing for truss system (not part of this component design) is always required.
LOAD CASE(S) Standard
TRUSS IS NOT DESIGNED TO SUPPORT ANY ADDITIONAL LOADS ON PANEL 8-10
Design valid for use only with MiTek connectors. This design is based only upon parameters shown, and is for an individual building component. Applicability of design parameters and proper incorporation of component is responsibility of building designer - not truss designer. Bracing shown is for lateral support of individual web members only. Additional temporary bracing to insure stability during construction is the responsibillity of theerector. Additional permanent bracing of the overall structure is the responsibility of the building designer. For general guidance regardingfabrication, quality control, storage, delivery, erection and bracing, consult 14515 N. Outer Forty, Suite #300
Chesterfield, MO 63017
ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 781 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information
February 12,2015
Job
1500058
Truss
E6
Truss Type
HIP
Qty
1
Ply
1
SOUTHILL C STANDARD
Job Reference (optional)
I23659126
7.430 s Jul 25 2013 MiTek Industries, Inc. Wed Feb 11 15:05:17 2015 Page 1 Timberland Lumber Company, Indianapolis, IN 46222
ID:6wSYySsChxEClNJ8ETXMjTzZ3cH-YLjBCqgzq9?QbC6B13XRx0Yh8G_v7WXDQaCKUozmAbm
Scale = 1:62.7
1
2
3
4 5
6
7
8
13 12 11 10 9
14
15 16
17
4x6 4x6
3x6 3x4 3x4
5x6
3x4
5x6
6x6
3x6
6x6
7-7-11
7-7-11
13-4-5
5-8-9
21-0-0
7-7-11
-1-3-4
1-3-4
3-11-10
3-11-10
7-7-11
3-8-2
13-4-5
5-8-9
17-0-6
3-8-2
21-0-0
3-11-10
22-3-4
1-3-4
1-6-010-3-110-5-01-6-010-3-114.00 12
Plate Offsets (X,Y): [2:0-2-0,0-1-8], [3:0-3-0,0-3-0], [4:0-3-4,0-1-15], [5:0-3-4,0-1-15], [6:0-3-0,0-3-0], [7:0-2-0,0-1-8], [9:Edge,0-1-8]
LOADING (psf)
TCLL
(Roof Snow=20.0)
TCDL
BCLL
BCDL
20.0
10.0
0.0
10.0
SPACING
Plates Increase
Lumber Increase
Rep Stress Incr
Code
2-0-0
1.15
1.15
YES
IRC2006/TPI2002
CSI
TC
BC
WB
(Matrix)
0.90
0.67
0.15
DEFL
Vert(LL)
Vert(TL)
Horz(TL)
in
-0.25
-0.36
0.02
(loc)
12-13
12-13
9
l/defl
>999
>686
n/a
L/d
240
180
n/a
PLATES
MT20
Weight: 110 lb FT = 0%
GRIP
197/144
LUMBER
TOP CHORD 2x4 SPF No.2 *Except*
1-3,6-8: 2x4 SP 2400F 2.0E
BOT CHORD 2x4 SPF No.2
WEBS 2x4 SPF No.2 *Except*
3-12,6-10: 2x4 SPF Stud/No.3, 2-13,7-9: 2x6 SPF No.2
BRACING
TOP CHORD Structural wood sheathing directly applied or 2-2-0 oc purlins, except
end verticals, and 2-0-0 oc purlins (6-0-0 max.): 4-5.
BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing.
MiTek recommends that Stabilizers and required cross bracing
be installed during truss erection, in accordance with Stabilizer
Installation guide.
REACTIONS (lb/size)13=912/0-3-8 (min. 0-2-3), 9=912/0-3-8 (min. 0-2-3)
Max Uplift13=-106(LC 6), 9=-106(LC 6)
Max Grav 13=1402(LC 16), 9=1402(LC 16)
FORCES (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
TOP CHORD 2-3=-1249/119, 3-4=-904/192, 4-5=-514/172, 5-6=-904/192, 6-7=-1249/119,
2-13=-1299/151, 7-9=-1299/151
BOT CHORD 12-13=0/599, 10-12=0/514, 9-10=0/599
NOTES
1) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=30ft; Cat. II; Exp B; enclosed; C-C Exterior(2); cantilever left and right
exposed ; end vertical left and right exposed; Lumber DOL=1.33 plate grip DOL=1.33
2) TCLL: ASCE 7-05; Pf=20.0 psf (flat roof snow); Category II; Exp B; Fully Exp.; Ct=1.1, Lu=50-0-0
3) Unbalanced snow loads have been considered for this design.
4) This truss has been designed for greater of min roof live load of 12.0 psf or 2.00 times flat roof load of 20.0 psf on overhangs
non-concurrent with other live loads.
5) This truss has been designed for basic load combinations, which include cases with reductions for multiple concurrent live loads.
6) Provide adequate drainage to prevent water ponding.
7) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
8) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) except (jt=lb) 13=106,
9=106.
9) "Semi-rigid pitchbreaks including heels" Member end fixity model was used in the analysis and design of this truss.
10) Graphical purlin representation does not depict the size or the orientation of the purlin along the top and/or bottom chord.
11) Warning: Additional permanent and stability bracing for truss system (not part of this component design) is always required.
LOAD CASE(S) Standard
TRUSS IS NOT DESIGNED TO SUPPORT ANY ADDITIONAL LOADS ON PANEL 10-12
Design valid for use only with MiTek connectors. This design is based only upon parameters shown, and is for an individual building component. Applicability of design parameters and proper incorporation of component is responsibility of building designer - not truss designer. Bracing shown is for lateral support of individual web members only. Additional temporary bracing to insure stability during construction is the responsibillity of theerector. Additional permanent bracing of the overall structure is the responsibility of the building designer. For general guidance regardingfabrication, quality control, storage, delivery, erection and bracing, consult 14515 N. Outer Forty, Suite #300
Chesterfield, MO 63017
ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 781 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information
February 12,2015
Job
1500058
Truss
EGR
Truss Type
SPECIAL
Qty
1
Ply
1
SOUTHILL C STANDARD
Job Reference (optional)
I23659127
7.430 s Jul 25 2013 MiTek Industries, Inc. Wed Feb 11 15:05:18 2015 Page 1 Timberland Lumber Company, Indianapolis, IN 46222
ID:6wSYySsChxEClNJ8ETXMjTzZ3cH-0XHZPAgcbS7HDMhNbn2gTD5vFgL6sqsMeExt0FzmAbl
Scale = 1:54.8
1
2
3
4
5
6
7
8
9
16 15 14 13 12 11 10
17 18 19 20
21
22
23
24
25 26 27 28
6x6
4x6
2x8 4x6 4x6
4x6
3x8
2x4
5x9
3x8
3x8
5x6
3x4
3x4
2-7-14
2-7-14
6-11-10
4-3-12
10-10-11
3-11-1
14-9-12
3-11-1
21-0-0
6-2-4
-1-3-4
1-3-4
0-6-0
0-6-0
4-9-12
4-3-12
9-1-8
4-3-12
11-1-11
2-0-3
14-9-12
3-8-1
18-5-13
3-8-1
21-0-0
2-6-3
22-3-4
1-3-4
1-6-01-11-18-8-101-6-01-11-114.00 12
Plate Offsets (X,Y): [2:0-3-6,0-2-7], [6:Edge,0-1-14]
LOADING (psf)
TCLL
(Roof Snow=20.0)
TCDL
BCLL
BCDL
20.0
10.0
0.0
10.0
SPACING
Plates Increase
Lumber Increase
Rep Stress Incr
Code
2-0-0
1.15
1.15
NO
IRC2006/TPI2002
CSI
TC
BC
WB
(Matrix)
0.75
0.60
0.66
DEFL
Vert(LL)
Vert(TL)
Horz(TL)
in
-0.15
-0.28
0.03
(loc)
12-14
12-14
10
l/defl
>999
>895
n/a
L/d
240
180
n/a
PLATES
MT20
Weight: 116 lb FT = 0%
GRIP
197/144
LUMBER
TOP CHORD 2x4 SPF No.2
BOT CHORD 2x6 SPF No.2
WEBS 2x4 SPF Stud/No.3 *Except*
2-16: 2x6 SPF No.2, 8-10: 2x4 SPF No.2
BRACING
TOP CHORD Structural wood sheathing directly applied or 3-10-7 oc purlins, except
end verticals, and 2-0-0 oc purlins (3-1-11 max.): 2-4.
BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing, Except:
6-0-0 oc bracing: 15-16.
MiTek recommends that Stabilizers and required cross bracing
be installed during truss erection, in accordance with Stabilizer
Installation guide.REACTIONS (lb/size)16=755/0-3-8 (min. 0-1-11), 10=867/0-3-8 (min. 0-1-8)
Max Horz 16=14(LC 6)
Max Uplift16=-213(LC 6), 10=-127(LC 6)
Max Grav 16=1084(LC 17), 10=867(LC 1)
FORCES (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
TOP CHORD 2-3=-1263/226, 3-4=-2515/399, 4-5=-1964/277, 5-6=-907/180, 6-7=-718/179,
7-8=-788/134, 2-16=-1023/195, 8-10=-754/159
BOT CHORD 14-15=-249/2311, 12-14=-287/2663, 11-12=-30/1207, 10-11=0/417
WEBS 4-12=-2097/336, 5-11=-1064/245, 6-11=-186/759, 2-15=-216/1386, 3-15=-1289/170,
3-14=-41/675, 4-14=-606/6, 5-12=-195/1484
NOTES
1) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=30ft; Cat. II; Exp B; enclosed; C-C Exterior(2) -1-3-4 to 22-3-4; cantilever left
and right exposed ; end vertical left and right exposed; Lumber DOL=1.33 plate grip DOL=1.33
2) TCLL: ASCE 7-05; Pf=20.0 psf (flat roof snow); Category II; Exp B; Fully Exp.; Ct=1.1, Lu=50-0-0
3) Unbalanced snow loads have been considered for this design.
4) This truss has been designed for greater of min roof live load of 12.0 psf or 2.00 times flat roof load of 20.0 psf on overhangs
non-concurrent with other live loads.
5) This truss has been designed for basic load combinations, which include cases with reductions for multiple concurrent live loads.
6) Provide adequate drainage to prevent water ponding.
7) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
8) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) except (jt=lb) 16=213,
10=127.
9) "Semi-rigid pitchbreaks including heels" Member end fixity model was used in the analysis and design of this truss.
10) Graphical purlin representation does not depict the size or the orientation of the purlin along the top and/or bottom chord.
11) Hanger(s) or other connection device(s) shall be provided sufficient to support concentrated load(s) 10 lb down and 24 lb up at 0-2-12,
10 lb down and 24 lb up at 2-6-12, 10 lb down and 24 lb up at 4-6-12, and 10 lb down and 24 lb up at 6-6-12, and 10 lb down and 24
lb up at 8-5-12 on top chord, and 34 lb up at 0-6-12, 34 lb up at 2-6-12, 34 lb up at 4-6-12, and 34 lb up at 6-6-12, and 34 lb up at
8-5-12 on bottom chord. The design/selection of such connection device(s) is the responsibility of others.
12) Warning: Additional permanent and stability bracing for truss system (not part of this component design) is always required.
13) In the LOAD CASE(S) section, loads applied to the face of the truss are noted as front (F) or back (B).Continued on page 2
Design valid for use only with MiTek connectors. This design is based only upon parameters shown, and is for an individual building component. Applicability of design parameters and proper incorporation of component is responsibility of building designer - not truss designer. Bracing shown is for lateral support of individual web members only. Additional temporary bracing to insure stability during construction is the responsibillity of theerector. Additional permanent bracing of the overall structure is the responsibility of the building designer. For general guidance regardingfabrication, quality control, storage, delivery, erection and bracing, consult 14515 N. Outer Forty, Suite #300
Chesterfield, MO 63017
ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 781 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information
February 12,2015
Job
1500058
Truss
EGR
Truss Type
SPECIAL
Qty
1
Ply
1
SOUTHILL C STANDARD
Job Reference (optional)
I23659127
7.430 s Jul 25 2013 MiTek Industries, Inc. Wed Feb 11 15:05:18 2015 Page 2 Timberland Lumber Company, Indianapolis, IN 46222
ID:6wSYySsChxEClNJ8ETXMjTzZ3cH-0XHZPAgcbS7HDMhNbn2gTD5vFgL6sqsMeExt0FzmAbl
LOAD CASE(S) Standard
1) Dead + Snow (balanced): Lumber Increase=1.15, Plate Increase=1.15
Uniform Loads (plf)
Vert: 1-2=-60, 2-4=-60, 4-6=-60, 6-8=-60, 8-9=-60, 10-16=-20
Concentrated Loads (lb)
Vert: 2=24(B) 15=17(B) 3=24(B) 17=24(B) 19=24(B) 20=24(B) 25=17(B) 26=17(B) 27=17(B) 28=17(B)
Design valid for use only with MiTek connectors. This design is based only upon parameters shown, and is for an individual building component. Applicability of design parameters and proper incorporation of component is responsibility of building designer - not truss designer. Bracing shown is for lateral support of individual web members only. Additional temporary bracing to insure stability during construction is the responsibillity of theerector. Additional permanent bracing of the overall structure is the responsibility of the building designer. For general guidance regardingfabrication, quality control, storage, delivery, erection and bracing, consult 14515 N. Outer Forty, Suite #300
Chesterfield, MO 63017
ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 781 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information
Job
1500058
Truss
F
Truss Type
COMMON
Qty
1
Ply
1
SOUTHILL C STANDARD
Job Reference (optional)
I23659128
7.430 s Jul 25 2013 MiTek Industries, Inc. Wed Feb 11 15:05:19 2015 Page 1 Timberland Lumber Company, Indianapolis, IN 46222
ID:6wSYySsChxEClNJ8ETXMjTzZ3cH-UkrydWhEMmF8qWGa8UZv0RdAZ3lmbP3VtuhRYhzmAbk
Scale = 1:37.6
1
2
3
4
5
6
7
10 9 8
11 12
4x6
3x8 3x4 3x4
2x4
3x4
2x4
3x8
5-11-2
5-11-2
12-0-14
6-1-12
18-0-0
5-11-2
-0-11-4
0-11-4
3-11-1
3-11-1
9-0-0
5-0-15
14-0-15
5-0-15
18-0-0
3-11-1
18-11-4
0-11-4
0-6-65-9-60-6-67.00 12
Plate Offsets (X,Y): [2:0-3-8,Edge], [6:0-3-8,Edge]
LOADING (psf)
TCLL
(Roof Snow=20.0)
TCDL
BCLL
BCDL
20.0
10.0
0.0
10.0
SPACING
Plates Increase
Lumber Increase
Rep Stress Incr
Code
2-0-0
1.15
1.15
YES
IRC2006/TPI2002
CSI
TC
BC
WB
(Matrix)
0.33
0.32
0.15
DEFL
Vert(LL)
Vert(TL)
Horz(TL)
in
-0.03
-0.09
0.03
(loc)
6-8
8-10
6
l/defl
>999
>999
n/a
L/d
240
180
n/a
PLATES
MT20
Weight: 69 lb FT = 0%
GRIP
197/144
LUMBER
TOP CHORD 2x4 SPF No.2
BOT CHORD 2x4 SPF No.2
WEBS 2x4 SPF Stud/No.3
WEDGE
Left: 2x4 SPF Stud/No.3, Right: 2x4 SPF Stud/No.3
BRACING
TOP CHORD Structural wood sheathing directly applied or 5-5-7 oc purlins.
BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing.
MiTek recommends that Stabilizers and required cross bracing
be installed during truss erection, in accordance with Stabilizer
Installation guide.
REACTIONS (lb/size)2=772/0-5-8 (min. 0-1-8), 6=772/0-5-8 (min. 0-1-8)
Max Uplift2=-83(LC 6), 6=-83(LC 6)
FORCES (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
TOP CHORD 2-3=-1060/96, 3-4=-909/110, 4-5=-909/110, 5-6=-1060/96
BOT CHORD 2-10=-21/838, 8-10=0/564, 6-8=-21/838
WEBS 4-8=-7/332, 4-10=-7/332
NOTES
1) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=30ft; Cat. II; Exp B; enclosed; C-C Exterior(2); cantilever left and right
exposed ; end vertical left and right exposed; Lumber DOL=1.33 plate grip DOL=1.33
2) TCLL: ASCE 7-05; Pf=20.0 psf (flat roof snow); Category II; Exp B; Fully Exp.; Ct=1.1
3) Unbalanced snow loads have been considered for this design.
4) This truss has been designed for greater of min roof live load of 16.0 psf or 2.00 times flat roof load of 20.0 psf on overhangs
non-concurrent with other live loads.
5) This truss has been designed for basic load combinations, which include cases with reductions for multiple concurrent live loads.
6) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 2, 6.
8) "Semi-rigid pitchbreaks including heels" Member end fixity model was used in the analysis and design of this truss.
9) Warning: Additional permanent and stability bracing for truss system (not part of this component design) is always required.
LOAD CASE(S) Standard
Design valid for use only with MiTek connectors. This design is based only upon parameters shown, and is for an individual building component. Applicability of design parameters and proper incorporation of component is responsibility of building designer - not truss designer. Bracing shown is for lateral support of individual web members only. Additional temporary bracing to insure stability during construction is the responsibillity of theerector. Additional permanent bracing of the overall structure is the responsibility of the building designer. For general guidance regardingfabrication, quality control, storage, delivery, erection and bracing, consult 14515 N. Outer Forty, Suite #300
Chesterfield, MO 63017
ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 781 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information
February 12,2015
Job
1500058
Truss
FG
Truss Type
GABLE
Qty
1
Ply
1
SOUTHILL C STANDARD
Job Reference (optional)
I23659129
7.430 s Jul 25 2013 MiTek Industries, Inc. Wed Feb 11 15:05:20 2015 Page 1 Timberland Lumber Company, Indianapolis, IN 46222
ID:6wSYySsChxEClNJ8ETXMjTzZ3cH-ywPKqsis74N?SgrmiB48ZeAPbTAJKukf6XQ_57zmAbj
Scale = 1:39.3
Sheet Front
Full Sheathing
1 Ply 1/2 x 4 x 8 Duramate
1
2
3
4
5
6
7
8
9
10
11
12
13
14 15
27 26 25 24 23 22 21 20 19 18 17 16
4x6
3x4
3x8 3x4
3x4 3x8
18-0-0
18-0-0
-0-11-4
0-11-4
9-0-0
9-0-0
18-0-0
9-0-0
18-11-4
0-11-4
0-6-65-9-60-6-67.00 12
Plate Offsets (X,Y): [2:0-0-0,0-0-11], [2:0-2-5,Edge], [14:0-0-0,0-0-11], [14:0-2-5,Edge]
LOADING (psf)
TCLL
(Roof Snow=20.0)
TCDL
BCLL
BCDL
20.0
10.0
0.0
10.0
SPACING
Plates Increase
Lumber Increase
Rep Stress Incr
Code
2-0-0
1.15
1.15
NO
IRC2006/TPI2002
CSI
TC
BC
WB
(Matrix)
0.12
0.04
0.06
DEFL
Vert(LL)
Vert(TL)
Horz(TL)
in
-0.00
0.00
0.00
(loc)
14
14
14
l/defl
n/r
n/r
n/a
L/d
120
120
n/a
PLATES
MT20
Weight: 87 lb FT = 0%
GRIP
197/144
LUMBER
TOP CHORD 2x4 SPF No.2
BOT CHORD 2x4 SPF No.2
OTHERS 2x4 SPF Stud/No.3
WEDGE
Left: 2x4 SPF Stud/No.3, Right: 2x4 SPF Stud/No.3
BRACING
TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins.
BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing.
MiTek recommends that Stabilizers and required cross bracing
be installed during truss erection, in accordance with Stabilizer
Installation guide.
REACTIONS All bearings 18-0-0.
(lb) - Max Uplift All uplift 100 lb or less at joint(s) 2, 23, 24, 25, 26, 27, 20, 19, 18, 17, 16, 14
Max Grav All reactions 250 lb or less at joint(s) 2, 21, 23, 24, 25, 26, 27, 20, 19, 18, 17, 16, 14
FORCES (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
NOTES
1) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=30ft; Cat. II; Exp B; enclosed; C-C Exterior(2); cantilever left and right
exposed ; end vertical left and right exposed; Lumber DOL=1.33 plate grip DOL=1.33
2) Truss designed for wind loads in the plane of the truss only. For studs exposed to wind (normal to the face), see Standard Industry
Gable End Details as applicable, or consult qualified building designer as per ANSI/TPI 1.
3) TCLL: ASCE 7-05; Pf=20.0 psf (flat roof snow); Category II; Exp B; Fully Exp.; Ct=1.1
4) Unbalanced snow loads have been considered for this design.
5) This truss has been designed for greater of min roof live load of 16.0 psf or 2.00 times flat roof load of 20.0 psf on overhangs
non-concurrent with other live loads.
6) This truss has been designed for basic load combinations, which include cases with reductions for multiple concurrent live loads.
7) All plates are 2x4 MT20 unless otherwise indicated.
8) Gable requires continuous bottom chord bearing.
9) Gable studs spaced at 1-4-0 oc.
10) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
11) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 2, 23, 24, 25, 26, 27,
20, 19, 18, 17, 16, 14.
12) "Semi-rigid pitchbreaks including heels" Member end fixity model was used in the analysis and design of this truss.
13) Warning: Additional permanent and stability bracing for truss system (not part of this component design) is always required.
LOAD CASE(S) Standard
Design valid for use only with MiTek connectors. This design is based only upon parameters shown, and is for an individual building component. Applicability of design parameters and proper incorporation of component is responsibility of building designer - not truss designer. Bracing shown is for lateral support of individual web members only. Additional temporary bracing to insure stability during construction is the responsibillity of theerector. Additional permanent bracing of the overall structure is the responsibility of the building designer. For general guidance regardingfabrication, quality control, storage, delivery, erection and bracing, consult 14515 N. Outer Forty, Suite #300
Chesterfield, MO 63017
ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 781 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information
February 12,2015
Job
1500058
Truss
FGR
Truss Type
COMMON
Qty
1
Ply
2
SOUTHILL C STANDARD
Job Reference (optional)
I23659130
7.430 s Jul 25 2013 MiTek Industries, Inc. Wed Feb 11 15:05:20 2015 Page 1 Timberland Lumber Company, Indianapolis, IN 46222
ID:6wSYySsChxEClNJ8ETXMjTzZ3cH-ywPKqsis74N?SgrmiB48ZeAIVT1BKf9f6XQ_57zmAbj
Scale = 1:37.1
1
2
3
4
5
6
7 8
9 10 11 12 13 14 15 16
5x9
5x6
5x9 12x12
2x4 2x4
9-0-0
9-0-0
18-0-0
9-0-0
4-4-8
4-4-8
9-0-0
4-7-8
13-7-8
4-7-8
18-0-0
4-4-8
0-6-65-9-60-6-67.00 12
Plate Offsets (X,Y): [6:0-6-0,0-7-8]
LOADING (psf)
TCLL
(Roof Snow=20.0)
TCDL
BCLL
BCDL
20.0
10.0
0.0
10.0
SPACING
Plates Increase
Lumber Increase
Rep Stress Incr
Code
2-0-0
1.15
1.15
NO
IRC2006/TPI2002
CSI
TC
BC
WB
(Matrix)
0.58
0.63
0.99
DEFL
Vert(LL)
Vert(TL)
Horz(TL)
in
-0.12
-0.31
0.04
(loc)
1-6
1-6
5
l/defl
>999
>678
n/a
L/d
240
180
n/a
PLATES
MT20
Weight: 223 lb FT = 0%
GRIP
197/144
LUMBER
TOP CHORD 2x4 SPF No.2
BOT CHORD 2x10 SP 2250F 1.9E
WEBS 2x4 SPF Stud/No.3 *Except*
3-6: 2x4 SPF No.2
BRACING
TOP CHORD Structural wood sheathing directly applied or 3-8-13 oc purlins.
BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing.
REACTIONS (lb/size)1=7182/0-5-8 (min. 0-3-0), 5=7548/0-5-8 (min. 0-3-2)
Max Uplift1=-520(LC 6), 5=-547(LC 6)
FORCES (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
TOP CHORD 1-2=-8527/673, 2-3=-8352/636, 3-4=-8352/636, 4-5=-8525/673
BOT CHORD 1-6=-533/7257, 5-6=-533/7253
WEBS 3-6=-551/8059
NOTES
1) 2-ply truss to be connected together with 10d (0.131"x3") nails as follows:
Top chords connected as follows: 2x4 - 1 row at 0-9-0 oc.
Bottom chords connected as follows: 2x10 - 2 rows staggered at 0-2-0 oc.
Webs connected as follows: 2x4 - 1 row at 0-9-0 oc.
2) All loads are considered equally applied to all plies, except if noted as front (F) or back (B) face in the LOAD CASE(S) section. Ply to ply
connections have been provided to distribute only loads noted as (F) or (B), unless otherwise indicated.
3) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=30ft; Cat. II; Exp B; enclosed; C-C Exterior(2); cantilever left and right
exposed ; end vertical left and right exposed; Lumber DOL=1.33 plate grip DOL=1.33
4) TCLL: ASCE 7-05; Pf=20.0 psf (flat roof snow); Category II; Exp B; Fully Exp.; Ct=1.1
5) Unbalanced snow loads have been considered for this design.
6) This truss has been designed for basic load combinations, which include cases with reductions for multiple concurrent live loads.
7) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
8) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) except (jt=lb) 1=520,
5=547.
9) "Semi-rigid pitchbreaks including heels" Member end fixity model was used in the analysis and design of this truss.
10) Hanger(s) or other connection device(s) shall be provided sufficient to support concentrated load(s) 1481 lb down and 108 lb up at
1-3-4, 1481 lb down and 108 lb up at 3-3-4, 1481 lb down and 108 lb up at 5-3-4, 1481 lb down and 108 lb up at 7-3-4, 1481 lb down
and 108 lb up at 9-3-4, 1481 lb down and 108 lb up at 11-3-4, 1481 lb down and 108 lb up at 13-3-4, and 1481 lb down and 108 lb up
at 15-3-4, and 1481 lb down and 108 lb up at 17-3-4 on bottom chord. The design/selection of such connection device(s) is the
responsibility of others.
11) Warning: Additional permanent and stability bracing for truss system (not part of this component design) is always required.
LOAD CASE(S) Standard
Continued on page 2
Design valid for use only with MiTek connectors. This design is based only upon parameters shown, and is for an individual building component. Applicability of design parameters and proper incorporation of component is responsibility of building designer - not truss designer. Bracing shown is for lateral support of individual web members only. Additional temporary bracing to insure stability during construction is the responsibillity of theerector. Additional permanent bracing of the overall structure is the responsibility of the building designer. For general guidance regardingfabrication, quality control, storage, delivery, erection and bracing, consult 14515 N. Outer Forty, Suite #300
Chesterfield, MO 63017
ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 781 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information
February 12,2015
Job
1500058
Truss
FGR
Truss Type
COMMON
Qty
1
Ply
2
SOUTHILL C STANDARD
Job Reference (optional)
I23659130
7.430 s Jul 25 2013 MiTek Industries, Inc. Wed Feb 11 15:05:20 2015 Page 2 Timberland Lumber Company, Indianapolis, IN 46222
ID:6wSYySsChxEClNJ8ETXMjTzZ3cH-ywPKqsis74N?SgrmiB48ZeAIVT1BKf9f6XQ_57zmAbj
LOAD CASE(S) Standard
1) Dead + Snow (balanced): Lumber Increase=1.15, Plate Increase=1.15
Uniform Loads (plf)
Vert: 1-3=-60, 3-5=-60, 1-5=-20
Concentrated Loads (lb)
Vert: 6=-1481(B) 9=-1481(B) 10=-1481(B) 11=-1481(B) 12=-1481(B) 13=-1481(B) 14=-1481(B) 15=-1481(B) 16=-1481(B)
Design valid for use only with MiTek connectors. This design is based only upon parameters shown, and is for an individual building component. Applicability of design parameters and proper incorporation of component is responsibility of building designer - not truss designer. Bracing shown is for lateral support of individual web members only. Additional temporary bracing to insure stability during construction is the responsibillity of theerector. Additional permanent bracing of the overall structure is the responsibility of the building designer. For general guidance regardingfabrication, quality control, storage, delivery, erection and bracing, consult 14515 N. Outer Forty, Suite #300
Chesterfield, MO 63017
ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 781 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information
Job
1500058
Truss
G
Truss Type
SCISSOR
Qty
4
Ply
1
SOUTHILL C STANDARD
Job Reference (optional)
I23659131
7.430 s Jul 25 2013 MiTek Industries, Inc. Wed Feb 11 15:05:21 2015 Page 1 Timberland Lumber Company, Indianapolis, IN 46222
ID:6wSYySsChxEClNJ8ETXMjTzZ3cH-Q6yi2CjUuNVs4qQyGvcN5sjRPtPr3J4oLBAXdZzmAbi
Scale = 1:56.4
1
2
3
4
7
6
5
8 9
4x6
3x8
3x6
5x6
3x6
3x8
6-0-0
6-0-0
12-0-0
6-0-0
-1-3-4
1-3-4
6-0-0
6-0-0
12-0-0
6-0-0
1-6-08-6-01-6-03-3-1514.00 12
7.00 12
Plate Offsets (X,Y): [3:Edge,0-1-14]
LOADING (psf)
TCLL
(Roof Snow=20.0)
TCDL
BCLL
BCDL
20.0
10.0
0.0
10.0
SPACING
Plates Increase
Lumber Increase
Rep Stress Incr
Code
2-0-0
1.15
1.15
YES
IRC2006/TPI2002
CSI
TC
BC
WB
(Matrix)
0.69
0.47
0.18
DEFL
Vert(LL)
Vert(TL)
Horz(TL)
in
-0.16
-0.26
0.31
(loc)
6
6
5
l/defl
>871
>550
n/a
L/d
240
180
n/a
PLATES
MT20
Weight: 48 lb FT = 0%
GRIP
197/144
LUMBER
TOP CHORD 2x4 SPF No.2
BOT CHORD 2x4 SPF No.2
WEBS 2x4 SPF No.2 *Except*
3-6: 2x4 SPF Stud/No.3
BRACING
TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except
end verticals.
BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing.
MiTek recommends that Stabilizers and required cross bracing
be installed during truss erection, in accordance with Stabilizer
Installation guide.
REACTIONS (lb/size)7=558/0-3-8 (min. 0-1-8), 5=463/0-3-8 (min. 0-1-8)
Max Horz 7=76(LC 6)
Max Uplift7=-101(LC 6), 5=-54(LC 6)
FORCES (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
TOP CHORD 2-3=-602/25, 3-4=-590/25, 2-7=-635/95, 4-5=-534/46
BOT CHORD 6-7=0/336, 5-6=0/333
WEBS 3-6=0/438
NOTES
1) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=30ft; Cat. II; Exp B; enclosed; C-C Exterior(2); cantilever left and right
exposed ; end vertical left and right exposed; Lumber DOL=1.33 plate grip DOL=1.33
2) TCLL: ASCE 7-05; Pf=20.0 psf (flat roof snow); Category II; Exp B; Fully Exp.; Ct=1.1
3) Unbalanced snow loads have been considered for this design.
4) This truss has been designed for greater of min roof live load of 12.0 psf or 2.00 times flat roof load of 20.0 psf on overhangs
non-concurrent with other live loads.
5) This truss has been designed for basic load combinations, which include cases with reductions for multiple concurrent live loads.
6) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
7) Bearing at joint(s) 7, 5 considers parallel to grain value using ANSI/TPI 1 angle to grain formula. Building designer should verify
capacity of bearing surface.
8) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 5 except (jt=lb)
7=101.
9) "Semi-rigid pitchbreaks including heels" Member end fixity model was used in the analysis and design of this truss.
10) Warning: Additional permanent and stability bracing for truss system (not part of this component design) is always required.
LOAD CASE(S) Standard
Design valid for use only with MiTek connectors. This design is based only upon parameters shown, and is for an individual building component. Applicability of design parameters and proper incorporation of component is responsibility of building designer - not truss designer. Bracing shown is for lateral support of individual web members only. Additional temporary bracing to insure stability during construction is the responsibillity of theerector. Additional permanent bracing of the overall structure is the responsibility of the building designer. For general guidance regardingfabrication, quality control, storage, delivery, erection and bracing, consult 14515 N. Outer Forty, Suite #300
Chesterfield, MO 63017
ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 781 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information
February 12,2015
Job
1500058
Truss
GG
Truss Type
GABLE
Qty
1
Ply
1
SOUTHILL C STANDARD
Job Reference (optional)
I23659132
7.430 s Jul 25 2013 MiTek Industries, Inc. Wed Feb 11 15:05:21 2015 Page 1 Timberland Lumber Company, Indianapolis, IN 46222
ID:6wSYySsChxEClNJ8ETXMjTzZ3cH-Q6yi2CjUuNVs4qQyGvcN5sjXktV63IJoLBAXdZzmAbi
Scale = 1:50.7
Sheet Front
Full Sheathing
1 Ply 1/2 x 4 x 8 Duramate
1
2
3
4
5
6
7
8
9
10
11
20
19
18
17
16
15
14
13
12
2x8
4x6
2x8
5x6
6-0-0
6-0-0
12-0-0
6-0-0
-1-3-4
1-3-4
6-0-0
6-0-0
12-0-0
6-0-0
13-3-4
1-3-4
1-6-08-6-01-6-03-3-1514.00 12
7.00 12
Plate Offsets (X,Y): [6:Edge,0-1-14]
LOADING (psf)
TCLL
(Roof Snow=20.0)
TCDL
BCLL
BCDL
20.0
10.0
0.0
10.0
SPACING
Plates Increase
Lumber Increase
Rep Stress Incr
Code
2-0-0
1.15
1.15
NO
IRC2006/TPI2002
CSI
TC
BC
WB
(Matrix)
0.29
0.07
0.23
DEFL
Vert(LL)
Vert(TL)
Horz(TL)
in
-0.01
-0.01
0.00
(loc)
11
11
12
l/defl
n/r
n/r
n/a
L/d
120
120
n/a
PLATES
MT20
Weight: 71 lb FT = 0%
GRIP
197/144
LUMBER
TOP CHORD 2x4 SPF No.2
BOT CHORD 2x4 SPF No.2
WEBS 2x4 SPF Stud/No.3
OTHERS 2x4 SPF Stud/No.3
BRACING
TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except
end verticals.
BOT CHORD Rigid ceiling directly applied or 6-0-0 oc bracing.
MiTek recommends that Stabilizers and required cross bracing
be installed during truss erection, in accordance with Stabilizer
Installation guide.
REACTIONS All bearings 12-0-0.
(lb) - Max Uplift All uplift 100 lb or less at joint(s) 17, 18, 19, 15, 14, 13 except
20=-189(LC 6), 12=-189(LC 6)
Max Grav All reactions 250 lb or less at joint(s) 20, 12, 17, 18, 19, 15, 14, 13
except 16=584(LC 6)
FORCES (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
TOP CHORD 4-5=-16/300, 5-6=-33/352, 6-7=-33/352, 7-8=-16/300
WEBS 6-16=-478/0
NOTES
1) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=30ft; Cat. II; Exp B; enclosed; C-C Exterior(2); cantilever left and right
exposed ; end vertical left and right exposed; Lumber DOL=1.33 plate grip DOL=1.33
2) Truss designed for wind loads in the plane of the truss only. For studs exposed to wind (normal to the face), see Standard Industry
Gable End Details as applicable, or consult qualified building designer as per ANSI/TPI 1.
3) TCLL: ASCE 7-05; Pf=20.0 psf (flat roof snow); Category II; Exp B; Fully Exp.; Ct=1.1
4) Unbalanced snow loads have been considered for this design.
5) This truss has been designed for greater of min roof live load of 12.0 psf or 2.00 times flat roof load of 20.0 psf on overhangs
non-concurrent with other live loads.
6) This truss has been designed for basic load combinations, which include cases with reductions for multiple concurrent live loads.
7) All plates are 2x4 MT20 unless otherwise indicated.
8) Gable requires continuous bottom chord bearing.
9) Truss to be fully sheathed from one face or securely braced against lateral movement (i.e. diagonal web).
10) Gable studs spaced at 1-4-0 oc.
11) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
12) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 17, 18, 19, 15, 14,
13 except (jt=lb) 20=189, 12=189.
13) Beveled plate or shim required to provide full bearing surface with truss chord at joint(s) 16, 17, 18, 19, 15, 14, 13.
14) "Semi-rigid pitchbreaks including heels" Member end fixity model was used in the analysis and design of this truss.
15) Warning: Additional permanent and stability bracing for truss system (not part of this component design) is always required.
LOAD CASE(S) Standard
Design valid for use only with MiTek connectors. This design is based only upon parameters shown, and is for an individual building component. Applicability of design parameters and proper incorporation of component is responsibility of building designer - not truss designer. Bracing shown is for lateral support of individual web members only. Additional temporary bracing to insure stability during construction is the responsibillity of theerector. Additional permanent bracing of the overall structure is the responsibility of the building designer. For general guidance regardingfabrication, quality control, storage, delivery, erection and bracing, consult 14515 N. Outer Forty, Suite #300
Chesterfield, MO 63017
ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 781 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information
February 12,2015
Job
1500058
Truss
HG
Truss Type
GABLE
Qty
1
Ply
1
SOUTHILL C STANDARD
Job Reference (optional)
I23659133
7.430 s Jul 25 2013 MiTek Industries, Inc. Wed Feb 11 15:05:22 2015 Page 1 Timberland Lumber Company, Indianapolis, IN 46222
ID:6wSYySsChxEClNJ8ETXMjTzZ3cH-uJW4FYj6fhdjhz?9qc7ce3FiUHruomAyZrv590zmAbh
Scale = 1:55.8
Sheet Front
Full Sheathing
1 Ply 1/2 x 4 x 8 Duramate
1
2
3
4
5
6
7
8
9
10
11
12
13
24 23 22 21 20 19 18 17 16 15 14
2x8
4x6
2x8
12-11-8
12-11-8
-1-3-4
1-3-4
6-5-12
6-5-12
12-11-8
6-5-12
14-2-12
1-3-4
1-10-39-4-141-10-314.00 12
Plate Offsets (X,Y): [7:Edge,0-1-14]
LOADING (psf)
TCLL
(Roof Snow=20.0)
TCDL
BCLL
BCDL
20.0
10.0
0.0
10.0
SPACING
Plates Increase
Lumber Increase
Rep Stress Incr
Code
2-0-0
1.15
1.15
NO
IRC2006/TPI2002
CSI
TC
BC
WB
(Matrix)
0.29
0.10
0.19
DEFL
Vert(LL)
Vert(TL)
Horz(TL)
in
-0.01
-0.01
0.00
(loc)
13
13
14
l/defl
n/r
n/r
n/a
L/d
120
120
n/a
PLATES
MT20
Weight: 101 lb FT = 0%
GRIP
197/144
LUMBER
TOP CHORD 2x4 SPF No.2
BOT CHORD 2x4 SPF No.2
WEBS 2x4 SPF Stud/No.3
OTHERS 2x4 SPF Stud/No.3 *Except*
7-19: 2x4 SPF No.2
BRACING
TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except
end verticals.
BOT CHORD Rigid ceiling directly applied or 6-0-0 oc bracing.
WEBS 1 Row at midpt 7-19
MiTek recommends that Stabilizers and required cross bracing
be installed during truss erection, in accordance with Stabilizer
Installation guide.
REACTIONS All bearings 12-11-8.
(lb) - Max Uplift All uplift 100 lb or less at joint(s) 20, 21, 22, 23, 18, 17, 16, 15
except 24=-116(LC 6), 14=-116(LC 6)
Max Grav All reactions 250 lb or less at joint(s) 24, 14, 20, 21, 22, 23, 18, 17, 16,
15 except 19=512(LC 6)
FORCES (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
TOP CHORD 5-6=-19/337, 6-7=-36/372, 7-8=-36/372, 8-9=-19/337
WEBS 7-19=-497/0
NOTES
1) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=30ft; Cat. II; Exp B; enclosed; C-C Exterior(2); cantilever left and right
exposed ; end vertical left and right exposed; Lumber DOL=1.33 plate grip DOL=1.33
2) Truss designed for wind loads in the plane of the truss only. For studs exposed to wind (normal to the face), see Standard Industry
Gable End Details as applicable, or consult qualified building designer as per ANSI/TPI 1.
3) TCLL: ASCE 7-05; Pf=20.0 psf (flat roof snow); Category II; Exp B; Fully Exp.; Ct=1.1
4) Unbalanced snow loads have been considered for this design.
5) This truss has been designed for greater of min roof live load of 12.0 psf or 2.00 times flat roof load of 20.0 psf on overhangs
non-concurrent with other live loads.
6) This truss has been designed for basic load combinations, which include cases with reductions for multiple concurrent live loads.
7) All plates are 2x4 MT20 unless otherwise indicated.
8) Gable requires continuous bottom chord bearing.
9) Truss to be fully sheathed from one face or securely braced against lateral movement (i.e. diagonal web).
10) Gable studs spaced at 1-4-0 oc.
11) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
12) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 20, 21, 22, 23, 18,
17, 16, 15 except (jt=lb) 24=116, 14=116.
13) "Semi-rigid pitchbreaks including heels" Member end fixity model was used in the analysis and design of this truss.
14) Warning: Additional permanent and stability bracing for truss system (not part of this component design) is always required.Continued on page 2
Design valid for use only with MiTek connectors. This design is based only upon parameters shown, and is for an individual building component. Applicability of design parameters and proper incorporation of component is responsibility of building designer - not truss designer. Bracing shown is for lateral support of individual web members only. Additional temporary bracing to insure stability during construction is the responsibillity of theerector. Additional permanent bracing of the overall structure is the responsibility of the building designer. For general guidance regardingfabrication, quality control, storage, delivery, erection and bracing, consult 14515 N. Outer Forty, Suite #300
Chesterfield, MO 63017
ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 781 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information
February 12,2015
Job
1500058
Truss
HG
Truss Type
GABLE
Qty
1
Ply
1
SOUTHILL C STANDARD
Job Reference (optional)
I23659133
7.430 s Jul 25 2013 MiTek Industries, Inc. Wed Feb 11 15:05:22 2015 Page 2 Timberland Lumber Company, Indianapolis, IN 46222
ID:6wSYySsChxEClNJ8ETXMjTzZ3cH-uJW4FYj6fhdjhz?9qc7ce3FiUHruomAyZrv590zmAbh
LOAD CASE(S) Standard
Design valid for use only with MiTek connectors. This design is based only upon parameters shown, and is for an individual building component. Applicability of design parameters and proper incorporation of component is responsibility of building designer - not truss designer. Bracing shown is for lateral support of individual web members only. Additional temporary bracing to insure stability during construction is the responsibillity of theerector. Additional permanent bracing of the overall structure is the responsibility of the building designer. For general guidance regardingfabrication, quality control, storage, delivery, erection and bracing, consult 14515 N. Outer Forty, Suite #300
Chesterfield, MO 63017
ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 781 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information
Job
1500058
Truss
HGR
Truss Type
HOWE
Qty
1
Ply
2
SOUTHILL C STANDARD
Job Reference (optional)
I23659134
7.430 s Jul 25 2013 MiTek Industries, Inc. Wed Feb 11 15:05:23 2015 Page 1 Timberland Lumber Company, Indianapolis, IN 46222
ID:6wSYySsChxEClNJ8ETXMjTzZ3cH-MV4STukkQ?laJ7aLNKerAHokUh_TX645oVfehSzmAbg
Scale = 1:61.2
1
2
3
4
5
6
7
10 9 8
17 18
11 12 13 14 15 16
4x6
10x10
4x6 4x6
2x8 2x8
6x6 6x6
0-4-8
0-4-8
6-5-12
6-1-4
12-11-8
6-5-12
-1-3-4
1-3-4
2-5-12
2-5-12
6-5-12
4-0-0
10-5-12
4-0-0
12-11-8
2-5-12
14-2-12
1-3-4
1-10-39-4-141-10-314.00 12
Plate Offsets (X,Y): [9:0-5-0,0-7-8]
LOADING (psf)
TCLL
(Roof Snow=20.0)
TCDL
BCLL
BCDL
20.0
10.0
0.0
10.0
SPACING
Plates Increase
Lumber Increase
Rep Stress Incr
Code
2-0-0
1.15
1.15
NO
IRC2006/TPI2002
CSI
TC
BC
WB
(Matrix)
0.85
0.91
0.59
DEFL
Vert(LL)
Vert(TL)
Horz(TL)
in
-0.04
-0.11
0.01
(loc)
9-10
9-10
8
l/defl
>999
>999
n/a
L/d
240
180
n/a
PLATES
MT20
Weight: 223 lb FT = 0%
GRIP
197/144
LUMBER
TOP CHORD 2x4 SPF No.2
BOT CHORD 2x10 SP No.2
WEBS 2x4 SPF Stud/No.3 *Except*
4-9: 2x4 SPF No.2
BRACING
TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except
end verticals.
BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing.
REACTIONS (lb/size)10=5356/0-3-8 (min. 0-3-3), 8=4311/0-3-8 (min. 0-2-9)
Max Uplift10=-450(LC 6), 8=-645(LC 6)
FORCES (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
TOP CHORD 2-3=-621/163, 3-4=-3433/377, 4-5=-3433/377, 5-6=-594/161, 6-8=-596/181,
2-10=-617/183
BOT CHORD 9-10=-31/1804, 8-9=-31/1800
WEBS 4-9=-463/4835, 3-9=0/593, 5-9=0/598, 3-10=-3029/173, 5-8=-3057/175
NOTES
1) 2-ply truss to be connected together with 10d (0.131"x3") nails as follows:
Top chords connected as follows: 2x4 - 1 row at 0-9-0 oc.
Bottom chords connected as follows: 2x10 - 2 rows staggered at 0-6-0 oc.
Webs connected as follows: 2x4 - 1 row at 0-9-0 oc.
2) All loads are considered equally applied to all plies, except if noted as front (F) or back (B) face in the LOAD CASE(S) section. Ply to ply
connections have been provided to distribute only loads noted as (F) or (B), unless otherwise indicated.
3) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=30ft; Cat. II; Exp B; enclosed; C-C Exterior(2); cantilever left and right
exposed ; end vertical left and right exposed; Lumber DOL=1.33 plate grip DOL=1.33
4) TCLL: ASCE 7-05; Pf=20.0 psf (flat roof snow); Category II; Exp B; Fully Exp.; Ct=1.1
5) Unbalanced snow loads have been considered for this design.
6) This truss has been designed for greater of min roof live load of 12.0 psf or 2.00 times flat roof load of 20.0 psf on overhangs
non-concurrent with other live loads.
7) This truss has been designed for basic load combinations, which include cases with reductions for multiple concurrent live loads.
8) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
9) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) except (jt=lb) 10=450,
8=645.
10) "Semi-rigid pitchbreaks including heels" Member end fixity model was used in the analysis and design of this truss.
11) Hanger(s) or other connection device(s) shall be provided sufficient to support concentrated load(s) 1481 lb down and 108 lb up at
1-0-4, 1481 lb down and 108 lb up at 3-0-4, 1481 lb down and 108 lb up at 5-0-4, 1481 lb down and 108 lb up at 7-0-4, 1481 lb down
and 108 lb up at 9-0-4, and 1481 lb down and 108 lb up at 11-0-4, and 402 lb up at 12-9-12 on bottom chord. The design/selection of
such connection device(s) is the responsibility of others.
12) Warning: Additional permanent and stability bracing for truss system (not part of this component design) is always required.
LOAD CASE(S) Standard
Continued on page 2
Design valid for use only with MiTek connectors. This design is based only upon parameters shown, and is for an individual building component. Applicability of design parameters and proper incorporation of component is responsibility of building designer - not truss designer. Bracing shown is for lateral support of individual web members only. Additional temporary bracing to insure stability during construction is the responsibillity of theerector. Additional permanent bracing of the overall structure is the responsibility of the building designer. For general guidance regardingfabrication, quality control, storage, delivery, erection and bracing, consult 14515 N. Outer Forty, Suite #300
Chesterfield, MO 63017
ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 781 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information
February 12,2015
Job
1500058
Truss
HGR
Truss Type
HOWE
Qty
1
Ply
2
SOUTHILL C STANDARD
Job Reference (optional)
I23659134
7.430 s Jul 25 2013 MiTek Industries, Inc. Wed Feb 11 15:05:23 2015 Page 2 Timberland Lumber Company, Indianapolis, IN 46222
ID:6wSYySsChxEClNJ8ETXMjTzZ3cH-MV4STukkQ?laJ7aLNKerAHokUh_TX645oVfehSzmAbg
LOAD CASE(S) Standard
1) Dead + Snow (balanced): Lumber Increase=1.15, Plate Increase=1.15
Uniform Loads (plf)
Vert: 8-10=-20, 1-2=-60, 2-4=-60, 4-6=-60, 6-7=-60
Concentrated Loads (lb)
Vert: 8=402(B) 11=-1481(B) 12=-1481(B) 13=-1481(B) 14=-1481(B) 15=-1481(B) 16=-1481(B)
Design valid for use only with MiTek connectors. This design is based only upon parameters shown, and is for an individual building component. Applicability of design parameters and proper incorporation of component is responsibility of building designer - not truss designer. Bracing shown is for lateral support of individual web members only. Additional temporary bracing to insure stability during construction is the responsibillity of theerector. Additional permanent bracing of the overall structure is the responsibility of the building designer. For general guidance regardingfabrication, quality control, storage, delivery, erection and bracing, consult 14515 N. Outer Forty, Suite #300
Chesterfield, MO 63017
ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 781 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information
Job
1500058
Truss
J
Truss Type
COMMON
Qty
1
Ply
1
SOUTHILL C STANDARD
Job Reference (optional)
I23659135
7.430 s Jul 25 2013 MiTek Industries, Inc. Wed Feb 11 15:05:23 2015 Page 1 Timberland Lumber Company, Indianapolis, IN 46222
ID:6wSYySsChxEClNJ8ETXMjTzZ3cH-MV4STukkQ?laJ7aLNKerAHojhh4kXEy5oVfehSzmAbg
Scale = 1:56.8
1
2
3
4
5
9 7 6
10 11
8
4x6
2x8 2x8 2x4
3x6 3x6
0-4-8
0-4-8
6-2-4
5-9-12
12-4-8
6-2-4
-1-3-4
1-3-4
6-2-4
6-2-4
12-4-8
6-2-4
13-7-12
1-3-4
1-6-08-8-101-6-014.00 12
Plate Offsets (X,Y): [3:Edge,0-1-14]
LOADING (psf)
TCLL
(Roof Snow=20.0)
TCDL
BCLL
BCDL
20.0
10.0
0.0
10.0
SPACING
Plates Increase
Lumber Increase
Rep Stress Incr
Code
2-0-0
1.15
1.15
NO
IRC2006/TPI2002
CSI
TC
BC
WB
(Matrix)
0.90
0.57
0.09
DEFL
Vert(LL)
Vert(TL)
Horz(TL)
in
-0.08
-0.11
0.00
(loc)
7-8
6-7
6
l/defl
>999
>999
n/a
L/d
240
180
n/a
PLATES
MT20
Weight: 53 lb FT = 0%
GRIP
197/144
LUMBER
TOP CHORD 2x4 SPF No.2
BOT CHORD 2x4 SPF No.2
WEBS 2x4 SPF Stud/No.3
BRACING
TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except
end verticals.
BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing.
MiTek recommends that Stabilizers and required cross bracing
be installed during truss erection, in accordance with Stabilizer
Installation guide.
REACTIONS (lb/size)6=550/0-3-8 (min. 0-1-8), 8=587/0-3-8 (min. 0-1-8)
Max Uplift6=-98(LC 6), 8=-120(LC 6)
FORCES (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
TOP CHORD 2-3=-412/117, 3-4=-407/112, 2-9=-486/175, 4-6=-479/168
NOTES
1) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=30ft; Cat. II; Exp B; enclosed; C-C Exterior(2); cantilever left and right
exposed ; end vertical left and right exposed; Lumber DOL=1.33 plate grip DOL=1.33
2) TCLL: ASCE 7-05; Pf=20.0 psf (flat roof snow); Category II; Exp B; Fully Exp.; Ct=1.1
3) Unbalanced snow loads have been considered for this design.
4) This truss has been designed for greater of min roof live load of 12.0 psf or 2.00 times flat roof load of 20.0 psf on overhangs
non-concurrent with other live loads.
5) This truss has been designed for basic load combinations, which include cases with reductions for multiple concurrent live loads.
6) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 6 except (jt=lb)
8=120.
8) "Semi-rigid pitchbreaks including heels" Member end fixity model was used in the analysis and design of this truss.
9) Warning: Additional permanent and stability bracing for truss system (not part of this component design) is always required.
LOAD CASE(S) Standard
Design valid for use only with MiTek connectors. This design is based only upon parameters shown, and is for an individual building component. Applicability of design parameters and proper incorporation of component is responsibility of building designer - not truss designer. Bracing shown is for lateral support of individual web members only. Additional temporary bracing to insure stability during construction is the responsibillity of theerector. Additional permanent bracing of the overall structure is the responsibility of the building designer. For general guidance regardingfabrication, quality control, storage, delivery, erection and bracing, consult 14515 N. Outer Forty, Suite #300
Chesterfield, MO 63017
ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 781 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information
February 12,2015
Job
1500058
Truss
JG
Truss Type
GABLE
Qty
1
Ply
1
SOUTHILL C STANDARD
Job Reference (optional)
I23659136
7.430 s Jul 25 2013 MiTek Industries, Inc. Wed Feb 11 15:05:24 2015 Page 1 Timberland Lumber Company, Indianapolis, IN 46222
ID:6wSYySsChxEClNJ8ETXMjTzZ3cH-rheqgDlMBItRxH8Xx194jUL2g4W0Gg?E19OCEuzmAbf
Scale = 1:51.9
Sheet Front
Full Sheathing
1 Ply 1/2 x 4 x 8 Duramate
1
2
3
4
5
6
7
8
9
10
11
12
13
24 23 22 21 20 19 18 17 16 15 14
2x8
4x6
2x8
12-4-8
12-4-8
-1-3-4
1-3-4
6-2-4
6-2-4
12-4-8
6-2-4
13-7-12
1-3-4
1-6-08-8-101-6-014.00 12
Plate Offsets (X,Y): [7:Edge,0-1-14]
LOADING (psf)
TCLL
(Roof Snow=20.0)
TCDL
BCLL
BCDL
20.0
10.0
0.0
10.0
SPACING
Plates Increase
Lumber Increase
Rep Stress Incr
Code
2-0-0
1.15
1.15
NO
IRC2006/TPI2002
CSI
TC
BC
WB
(Matrix)
0.31
0.12
0.17
DEFL
Vert(LL)
Vert(TL)
Horz(TL)
in
-0.01
-0.01
0.00
(loc)
13
13
14
l/defl
n/r
n/r
n/a
L/d
120
120
n/a
PLATES
MT20
Weight: 91 lb FT = 0%
GRIP
197/144
LUMBER
TOP CHORD 2x4 SPF No.2
BOT CHORD 2x4 SPF No.2
WEBS 2x4 SPF Stud/No.3
OTHERS 2x4 SPF Stud/No.3
BRACING
TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except
end verticals.
BOT CHORD Rigid ceiling directly applied or 6-0-0 oc bracing.
WEBS 1 Row at midpt 7-19
MiTek recommends that Stabilizers and required cross bracing
be installed during truss erection, in accordance with Stabilizer
Installation guide.
REACTIONS All bearings 12-4-8.
(lb) - Max Uplift All uplift 100 lb or less at joint(s) 24, 14, 20, 21, 22, 23, 18, 17, 16,
15
Max Grav All reactions 250 lb or less at joint(s) 24, 14, 20, 21, 22, 23, 18, 17, 16,
15 except 19=422(LC 6)
FORCES (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
TOP CHORD 5-6=-19/270, 6-7=-36/311, 7-8=-36/311, 8-9=-19/270
WEBS 7-19=-407/0
NOTES
1) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=30ft; Cat. II; Exp B; enclosed; C-C Exterior(2); cantilever left and right
exposed ; end vertical left and right exposed; Lumber DOL=1.33 plate grip DOL=1.33
2) Truss designed for wind loads in the plane of the truss only. For studs exposed to wind (normal to the face), see Standard Industry
Gable End Details as applicable, or consult qualified building designer as per ANSI/TPI 1.
3) TCLL: ASCE 7-05; Pf=20.0 psf (flat roof snow); Category II; Exp B; Fully Exp.; Ct=1.1
4) Unbalanced snow loads have been considered for this design.
5) This truss has been designed for greater of min roof live load of 12.0 psf or 2.00 times flat roof load of 20.0 psf on overhangs
non-concurrent with other live loads.
6) This truss has been designed for basic load combinations, which include cases with reductions for multiple concurrent live loads.
7) All plates are 2x4 MT20 unless otherwise indicated.
8) Gable requires continuous bottom chord bearing.
9) Truss to be fully sheathed from one face or securely braced against lateral movement (i.e. diagonal web).
10) Gable studs spaced at 1-4-0 oc.
11) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
12) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 24, 14, 20, 21, 22,
23, 18, 17, 16, 15.
13) "Semi-rigid pitchbreaks including heels" Member end fixity model was used in the analysis and design of this truss.
14) Warning: Additional permanent and stability bracing for truss system (not part of this component design) is always required.Continued on page 2
Design valid for use only with MiTek connectors. This design is based only upon parameters shown, and is for an individual building component. Applicability of design parameters and proper incorporation of component is responsibility of building designer - not truss designer. Bracing shown is for lateral support of individual web members only. Additional temporary bracing to insure stability during construction is the responsibillity of theerector. Additional permanent bracing of the overall structure is the responsibility of the building designer. For general guidance regardingfabrication, quality control, storage, delivery, erection and bracing, consult 14515 N. Outer Forty, Suite #300
Chesterfield, MO 63017
ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 781 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information
February 12,2015
Job
1500058
Truss
JG
Truss Type
GABLE
Qty
1
Ply
1
SOUTHILL C STANDARD
Job Reference (optional)
I23659136
7.430 s Jul 25 2013 MiTek Industries, Inc. Wed Feb 11 15:05:24 2015 Page 2 Timberland Lumber Company, Indianapolis, IN 46222
ID:6wSYySsChxEClNJ8ETXMjTzZ3cH-rheqgDlMBItRxH8Xx194jUL2g4W0Gg?E19OCEuzmAbf
LOAD CASE(S) Standard
Design valid for use only with MiTek connectors. This design is based only upon parameters shown, and is for an individual building component. Applicability of design parameters and proper incorporation of component is responsibility of building designer - not truss designer. Bracing shown is for lateral support of individual web members only. Additional temporary bracing to insure stability during construction is the responsibillity of theerector. Additional permanent bracing of the overall structure is the responsibility of the building designer. For general guidance regardingfabrication, quality control, storage, delivery, erection and bracing, consult 14515 N. Outer Forty, Suite #300
Chesterfield, MO 63017
ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 781 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information
Job
1500058
Truss
K
Truss Type
JACK
Qty
5
Ply
1
SOUTHILL C STANDARD
Job Reference (optional)
I23659137
7.430 s Jul 25 2013 MiTek Industries, Inc. Wed Feb 11 15:05:24 2015 Page 1 Timberland Lumber Company, Indianapolis, IN 46222
ID:6wSYySsChxEClNJ8ETXMjTzZ3cH-rheqgDlMBItRxH8Xx194jUL234W5GiaE19OCEuzmAbf
Scale = 1:13.8
1
2
5
3
42x4
2x8
1-2-8
1-2-8
-1-3-4
1-3-4
1-2-8
1-2-8
1-0-152-1-01-5-82-1-010.00 12
LOADING (psf)
TCLL
(Roof Snow=20.0)
TCDL
BCLL
BCDL
20.0
10.0
0.0
10.0
SPACING
Plates Increase
Lumber Increase
Rep Stress Incr
Code
2-0-0
1.15
1.15
NO
IRC2006/TPI2002
CSI
TC
BC
WB
(Matrix)
0.28
0.12
0.00
DEFL
Vert(LL)
Vert(TL)
Horz(TL)
in
0.00
0.00
-0.01
(loc)
5
5
3
l/defl
>999
>999
n/a
L/d
240
180
n/a
PLATES
MT20
Weight: 6 lb FT = 0%
GRIP
197/144
LUMBER
TOP CHORD 2x4 SPF No.2
BOT CHORD 2x4 SPF Stud/No.3
WEBS 2x4 SPF Stud/No.3
BRACING
TOP CHORD Structural wood sheathing directly applied or 1-2-8 oc purlins, except
end verticals.
BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing.
MiTek recommends that Stabilizers and required cross bracing
be installed during truss erection, in accordance with Stabilizer
Installation guide.
REACTIONS (lb/size)5=185/0-3-8 (min. 0-1-8), 4=-3/Mechanical, 3=-14/Mechanical
Max Horz 5=115(LC 6)
Max Uplift5=-31(LC 6), 4=-22(LC 6), 3=-62(LC 7)
Max Grav 5=259(LC 7), 4=16(LC 5)
FORCES (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
NOTES
1) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=30ft; Cat. II; Exp B; enclosed; C-C Exterior(2); cantilever left and right
exposed ; end vertical left and right exposed; Lumber DOL=1.33 plate grip DOL=1.33
2) TCLL: ASCE 7-05; Pf=20.0 psf (flat roof snow); Category II; Exp B; Fully Exp.; Ct=1.1
3) Unbalanced snow loads have been considered for this design.
4) This truss has been designed for greater of min roof live load of 16.0 psf or 2.00 times flat roof load of 20.0 psf on overhangs
non-concurrent with other live loads.
5) This truss has been designed for basic load combinations, which include cases with reductions for multiple concurrent live loads.
6) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
7) Refer to girder(s) for truss to truss connections.
8) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 5, 4, 3.
9) "Semi-rigid pitchbreaks including heels" Member end fixity model was used in the analysis and design of this truss.
10) Warning: Additional permanent and stability bracing for truss system (not part of this component design) is always required.
LOAD CASE(S) Standard
Design valid for use only with MiTek connectors. This design is based only upon parameters shown, and is for an individual building component. Applicability of design parameters and proper incorporation of component is responsibility of building designer - not truss designer. Bracing shown is for lateral support of individual web members only. Additional temporary bracing to insure stability during construction is the responsibillity of theerector. Additional permanent bracing of the overall structure is the responsibility of the building designer. For general guidance regardingfabrication, quality control, storage, delivery, erection and bracing, consult 14515 N. Outer Forty, Suite #300
Chesterfield, MO 63017
ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 781 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information
February 12,2015
Job
1500058
Truss
KGR
Truss Type
MONO TRUSS
Qty
1
Ply
1
SOUTHILL C STANDARD
Job Reference (optional)
I23659138
7.430 s Jul 25 2013 MiTek Industries, Inc. Wed Feb 11 15:05:25 2015 Page 1 Timberland Lumber Company, Indianapolis, IN 46222
ID:6wSYySsChxEClNJ8ETXMjTzZ3cH-JuCDtZm?yc?HZRjkVlgJGit7yUtj?9qOFp8lmLzmAbe
Scale = 1:13.5
1
2
3
5
4
2x4
2x4 2x4
2x8
0-10-13
0-10-13
-2-0-10
2-0-10
0-10-13
0-10-13
1-4-152-0-48.14 12
LOADING (psf)
TCLL
(Roof Snow=20.0)
TCDL
BCLL
BCDL
20.0
10.0
0.0
10.0
SPACING
Plates Increase
Lumber Increase
Rep Stress Incr
Code
2-0-0
1.15
1.15
NO
IRC2006/TPI2002
CSI
TC
BC
WB
(Matrix)
0.66
0.03
0.00
DEFL
Vert(LL)
Vert(TL)
Horz(TL)
in
-0.00
-0.00
-0.00
(loc)
5
5
4
l/defl
>999
>999
n/a
L/d
240
180
n/a
PLATES
MT20
Weight: 8 lb FT = 0%
GRIP
197/144
LUMBER
TOP CHORD 2x4 SPF No.2
BOT CHORD 2x6 SPF No.2
WEBS 2x4 SPF Stud/No.3
BRACING
TOP CHORD Structural wood sheathing directly applied or 0-10-13 oc purlins,
except end verticals.
BOT CHORD Rigid ceiling directly applied or 6-0-0 oc bracing.
MiTek recommends that Stabilizers and required cross bracing
be installed during truss erection, in accordance with Stabilizer
Installation guide.
REACTIONS (lb/size)4=-213/Mechanical, 5=394/0-3-8 (min. 0-1-8)
Max Horz 5=5(LC 6)
Max Uplift4=-384(LC 7), 5=-251(LC 6)
Max Grav 4=163(LC 6), 5=628(LC 7)
FORCES (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
TOP CHORD 3-4=-164/328, 2-5=-560/260
NOTES
1) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=30ft; Cat. II; Exp B; enclosed; C-C Exterior(2); cantilever left and right
exposed ; end vertical left and right exposed; Lumber DOL=1.33 plate grip DOL=1.33
2) TCLL: ASCE 7-05; Pf=20.0 psf (flat roof snow); Category II; Exp B; Fully Exp.; Ct=1.1
3) Unbalanced snow loads have been considered for this design.
4) This truss has been designed for greater of min roof live load of 16.0 psf or 2.00 times flat roof load of 20.0 psf on overhangs
non-concurrent with other live loads.
5) This truss has been designed for basic load combinations, which include cases with reductions for multiple concurrent live loads.
6) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
7) Refer to girder(s) for truss to truss connections.
8) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) except (jt=lb) 4=384,
5=251.
9) "Semi-rigid pitchbreaks including heels" Member end fixity model was used in the analysis and design of this truss.
10) Warning: Additional permanent and stability bracing for truss system (not part of this component design) is always required.
LOAD CASE(S) Standard
Design valid for use only with MiTek connectors. This design is based only upon parameters shown, and is for an individual building component. Applicability of design parameters and proper incorporation of component is responsibility of building designer - not truss designer. Bracing shown is for lateral support of individual web members only. Additional temporary bracing to insure stability during construction is the responsibillity of theerector. Additional permanent bracing of the overall structure is the responsibility of the building designer. For general guidance regardingfabrication, quality control, storage, delivery, erection and bracing, consult 14515 N. Outer Forty, Suite #300
Chesterfield, MO 63017
ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 781 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information
February 12,2015
Job
1500058
Truss
L
Truss Type
MONO W/LEDGER POCKET
Qty
4
Ply
1
SOUTHILL C STANDARD
Job Reference (optional)
I23659139
7.430 s Jul 25 2013 MiTek Industries, Inc. Wed Feb 11 15:05:25 2015 Page 1 Timberland Lumber Company, Indianapolis, IN 46222
ID:6wSYySsChxEClNJ8ETXMjTzZ3cH-JuCDtZm?yc?HZRjkVlgJGitCpUqU?9qOFp8lmLzmAbe
Scale = 1:18.1
1
2
3
4
5
2x4
2x4
2x4
4-11-8
4-11-8
-0-11-4
0-11-4
4-11-8
4-11-8
0-5-132-11-96.00 12
LOADING (psf)
TCLL
(Roof Snow=20.0)
TCDL
BCLL
BCDL
20.0
10.0
0.0
10.0
SPACING
Plates Increase
Lumber Increase
Rep Stress Incr
Code
2-0-0
1.15
1.15
YES
IRC2006/TPI2002
CSI
TC
BC
WB
(Matrix)
0.35
0.24
0.00
DEFL
Vert(LL)
Vert(TL)
Horz(TL)
in
-0.03
-0.07
0.00
(loc)
2-4
2-4
4
l/defl
>999
>788
n/a
L/d
240
180
n/a
PLATES
MT20
Weight: 16 lb FT = 0%
GRIP
197/144
LUMBER
TOP CHORD 2x4 SPF No.2
BOT CHORD 2x4 SPF No.2
WEBS 2x4 SPF Stud/No.3
BRACING
TOP CHORD Structural wood sheathing directly applied or 4-11-8 oc purlins, except
end verticals.
BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing.
MiTek recommends that Stabilizers and required cross bracing
be installed during truss erection, in accordance with Stabilizer
Installation guide.
REACTIONS (lb/size)2=259/0-3-8 (min. 0-1-8), 4=179/0-3-8 (min. 0-1-8)
Max Horz 2=54(LC 6)
Max Uplift2=-93(LC 6), 4=-57(LC 6)
Max Grav 2=262(LC 8), 4=193(LC 8)
FORCES (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
NOTES
1) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=30ft; Cat. II; Exp B; enclosed; C-C Exterior(2); cantilever left and right
exposed ; end vertical left and right exposed; Lumber DOL=1.33 plate grip DOL=1.33
2) TCLL: ASCE 7-05; Pf=20.0 psf (flat roof snow); Category II; Exp B; Fully Exp.; Ct=1.1
3) Unbalanced snow loads have been considered for this design.
4) This truss has been designed for greater of min roof live load of 16.0 psf or 2.00 times flat roof load of 20.0 psf on overhangs
non-concurrent with other live loads.
5) This truss has been designed for basic load combinations, which include cases with reductions for multiple concurrent live loads.
6) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 2, 4.
8) "Semi-rigid pitchbreaks including heels" Member end fixity model was used in the analysis and design of this truss.
9) Warning: Additional permanent and stability bracing for truss system (not part of this component design) is always required.
LOAD CASE(S) Standard
Design valid for use only with MiTek connectors. This design is based only upon parameters shown, and is for an individual building component. Applicability of design parameters and proper incorporation of component is responsibility of building designer - not truss designer. Bracing shown is for lateral support of individual web members only. Additional temporary bracing to insure stability during construction is the responsibillity of theerector. Additional permanent bracing of the overall structure is the responsibility of the building designer. For general guidance regardingfabrication, quality control, storage, delivery, erection and bracing, consult 14515 N. Outer Forty, Suite #300
Chesterfield, MO 63017
ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 781 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information
February 12,2015
Job
1500058
Truss
L1
Truss Type
MONO W/LEDGER POCKET
Qty
1
Ply
1
SOUTHILL C STANDARD
Job Reference (optional)
I23659140
7.430 s Jul 25 2013 MiTek Industries, Inc. Wed Feb 11 15:05:26 2015 Page 1 Timberland Lumber Company, Indianapolis, IN 46222
ID:6wSYySsChxEClNJ8ETXMjTzZ3cH-n4mb5vndjw78AbIw3SBYovQHHu7ckc4XUTtIInzmAbd
Scale = 1:22.9
1
2
3
4
5
2x4
2x4
2x4
6-7-8
6-7-8
-0-11-4
0-11-4
6-7-8
6-7-8
0-5-133-9-96.00 12
LOADING (psf)
TCLL
(Roof Snow=20.0)
TCDL
BCLL
BCDL
20.0
10.0
0.0
10.0
SPACING
Plates Increase
Lumber Increase
Rep Stress Incr
Code
2-0-0
1.15
1.15
YES
IRC2006/TPI2002
CSI
TC
BC
WB
(Matrix)
0.68
0.44
0.00
DEFL
Vert(LL)
Vert(TL)
Horz(TL)
in
-0.10
-0.24
0.00
(loc)
2-4
2-4
4
l/defl
>788
>315
n/a
L/d
240
180
n/a
PLATES
MT20
Weight: 21 lb FT = 0%
GRIP
197/144
LUMBER
TOP CHORD 2x4 SPF No.2
BOT CHORD 2x4 SPF No.2
WEBS 2x4 SPF Stud/No.3
BRACING
TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except
end verticals.
BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing.
MiTek recommends that Stabilizers and required cross bracing
be installed during truss erection, in accordance with Stabilizer
Installation guide.
REACTIONS (lb/size)2=324/0-3-8 (min. 0-1-8), 4=248/0-3-8 (min. 0-1-8)
Max Horz 2=62(LC 6)
Max Uplift2=-102(LC 6), 4=-73(LC 6)
Max Grav 2=330(LC 8), 4=275(LC 8)
FORCES (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
NOTES
1) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=30ft; Cat. II; Exp B; enclosed; C-C Exterior(2); cantilever left and right
exposed ; end vertical left and right exposed; Lumber DOL=1.33 plate grip DOL=1.33
2) TCLL: ASCE 7-05; Pf=20.0 psf (flat roof snow); Category II; Exp B; Fully Exp.; Ct=1.1
3) Unbalanced snow loads have been considered for this design.
4) This truss has been designed for greater of min roof live load of 16.0 psf or 2.00 times flat roof load of 20.0 psf on overhangs
non-concurrent with other live loads.
5) This truss has been designed for basic load combinations, which include cases with reductions for multiple concurrent live loads.
6) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 4 except (jt=lb)
2=102.
8) "Semi-rigid pitchbreaks including heels" Member end fixity model was used in the analysis and design of this truss.
9) Warning: Additional permanent and stability bracing for truss system (not part of this component design) is always required.
LOAD CASE(S) Standard
Design valid for use only with MiTek connectors. This design is based only upon parameters shown, and is for an individual building component. Applicability of design parameters and proper incorporation of component is responsibility of building designer - not truss designer. Bracing shown is for lateral support of individual web members only. Additional temporary bracing to insure stability during construction is the responsibillity of theerector. Additional permanent bracing of the overall structure is the responsibility of the building designer. For general guidance regardingfabrication, quality control, storage, delivery, erection and bracing, consult 14515 N. Outer Forty, Suite #300
Chesterfield, MO 63017
ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 781 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information
February 12,2015
Job
1500058
Truss
LG
Truss Type
GABLE
Qty
1
Ply
1
SOUTHILL C STANDARD
Job Reference (optional)
I23659141
7.430 s Jul 25 2013 MiTek Industries, Inc. Wed Feb 11 15:05:26 2015 Page 1 Timberland Lumber Company, Indianapolis, IN 46222
ID:6wSYySsChxEClNJ8ETXMjTzZ3cH-n4mb5vndjw78AbIw3SBYovQPWuCckc4XUTtIInzmAbd
Scale = 1:13.8
Sheet Front
Full Sheathing
1 Ply 1/2 x 4 x 8 Duramate
1
2
3
4
5
2x4
2x4 2x4
-0-11-4
0-11-4
3-3-0
3-3-0
0-5-132-1-56.00 12
LOADING (psf)
TCLL
(Roof Snow=20.0)
TCDL
BCLL
BCDL
20.0
10.0
0.0
10.0
SPACING
Plates Increase
Lumber Increase
Rep Stress Incr
Code
2-0-0
1.15
1.15
NO
IRC2006/TPI2002
CSI
TC
BC
WB
(Matrix)
0.16
0.12
0.00
DEFL
Vert(LL)
Vert(TL)
Horz(TL)
in
0.00
0.01
0.00
(loc)
1
1
4
l/defl
n/r
n/r
n/a
L/d
120
120
n/a
PLATES
MT20
Weight: 11 lb FT = 0%
GRIP
197/144
LUMBER
TOP CHORD 2x4 SPF No.2
BOT CHORD 2x4 SPF No.2
WEBS 2x4 SPF Stud/No.3
BRACING
TOP CHORD Structural wood sheathing directly applied or 3-3-0 oc purlins, except
end verticals.
BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing.
MiTek recommends that Stabilizers and required cross bracing
be installed during truss erection, in accordance with Stabilizer
Installation guide.
REACTIONS (lb/size)4=116/3-3-0 (min. 0-1-8), 2=189/3-3-0 (min. 0-1-8)
Max Horz 2=41(LC 6)
Max Uplift4=-35(LC 6), 2=-74(LC 6)
Max Grav 4=119(LC 8), 2=189(LC 8)
FORCES (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
NOTES
1) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=30ft; Cat. II; Exp B; enclosed; C-C Exterior(2); cantilever left and right
exposed ; end vertical left and right exposed; Lumber DOL=1.33 plate grip DOL=1.33
2) Truss designed for wind loads in the plane of the truss only. For studs exposed to wind (normal to the face), see Standard Industry
Gable End Details as applicable, or consult qualified building designer as per ANSI/TPI 1.
3) TCLL: ASCE 7-05; Pf=20.0 psf (flat roof snow); Category II; Exp B; Fully Exp.; Ct=1.1
4) Unbalanced snow loads have been considered for this design.
5) This truss has been designed for greater of min roof live load of 16.0 psf or 2.00 times flat roof load of 20.0 psf on overhangs
non-concurrent with other live loads.
6) This truss has been designed for basic load combinations, which include cases with reductions for multiple concurrent live loads.
7) Gable requires continuous bottom chord bearing.
8) Gable studs spaced at 1-4-0 oc.
9) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
10) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 4, 2.
11) "Semi-rigid pitchbreaks including heels" Member end fixity model was used in the analysis and design of this truss.
12) Warning: Additional permanent and stability bracing for truss system (not part of this component design) is always required.
LOAD CASE(S) Standard
Design valid for use only with MiTek connectors. This design is based only upon parameters shown, and is for an individual building component. Applicability of design parameters and proper incorporation of component is responsibility of building designer - not truss designer. Bracing shown is for lateral support of individual web members only. Additional temporary bracing to insure stability during construction is the responsibillity of theerector. Additional permanent bracing of the overall structure is the responsibility of the building designer. For general guidance regardingfabrication, quality control, storage, delivery, erection and bracing, consult 14515 N. Outer Forty, Suite #300
Chesterfield, MO 63017
ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 781 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information
February 12,2015
Job
1500058
Truss
PBA
Truss Type
SPECIAL
Qty
8
Ply
1
SOUTHILL C STANDARD
Job Reference (optional)
I23659142
7.430 s Jul 25 2013 MiTek Industries, Inc. Wed Feb 11 15:05:26 2015 Page 1 Timberland Lumber Company, Indianapolis, IN 46222
ID:6wSYySsChxEClNJ8ETXMjTzZ3cH-n4mb5vndjw78AbIw3SBYovQQruB4kc4XUTtIInzmAbd
Scale = 1:16.3
12
3
4
5
3x4
2x4 2x4
0-0-3
0-0-3
4-8-6
4-8-2
4-8-9
0-0-3
2-4-5
2-4-5
4-8-9
2-4-5
0-5-102-9-00-1-100-5-100-1-1014.00 12
Plate Offsets (X,Y): [2:0-2-10,0-1-0], [3:Edge,0-3-1], [4:0-2-10,0-1-0]
LOADING (psf)
TCLL
(Roof Snow=20.0)
TCDL
BCLL
BCDL
20.0
10.0
0.0
10.0
SPACING
Plates Increase
Lumber Increase
Rep Stress Incr
Code
2-0-0
1.15
1.15
YES
IRC2006/TPI2002
CSI
TC
BC
WB
(Matrix)
0.07
0.15
0.00
DEFL
Vert(LL)
Vert(TL)
Horz(TL)
in
0.00
0.00
0.00
(loc)
5
4
4
l/defl
n/r
n/r
n/a
L/d
120
120
n/a
PLATES
MT20
Weight: 12 lb FT = 0%
GRIP
197/144
LUMBER
TOP CHORD 2x4 SPF No.2
BOT CHORD 2x4 SPF No.2
BRACING
TOP CHORD Structural wood sheathing directly applied or 4-8-9 oc purlins.
BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing.
MiTek recommends that Stabilizers and required cross bracing
be installed during truss erection, in accordance with Stabilizer
Installation guide.
REACTIONS (lb/size)2=166/3-8-2 (min. 0-1-8), 4=166/3-8-2 (min. 0-1-8)
Max Uplift2=-39(LC 6), 4=-39(LC 6)
FORCES (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
NOTES
1) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=30ft; Cat. II; Exp B; enclosed; C-C Exterior(2); cantilever left and right
exposed ; end vertical left and right exposed; Lumber DOL=1.33 plate grip DOL=1.33
2) TCLL: ASCE 7-05; Pf=20.0 psf (flat roof snow); Category II; Exp B; Fully Exp.; Ct=1.1
3) Unbalanced snow loads have been considered for this design.
4) This truss has been designed for greater of min roof live load of 12.0 psf or 2.00 times flat roof load of 20.0 psf on overhangs
non-concurrent with other live loads.
5) This truss has been designed for basic load combinations, which include cases with reductions for multiple concurrent live loads.
6) Gable requires continuous bottom chord bearing.
7) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
8) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 2, 4.
9) "Semi-rigid pitchbreaks including heels" Member end fixity model was used in the analysis and design of this truss.
10) See Standard Industry Piggyback Truss Connection Detail for Connection to base truss as applicable, or consult qualified building
designer.
11) Warning: Additional permanent and stability bracing for truss system (not part of this component design) is always required.
LOAD CASE(S) Standard
Design valid for use only with MiTek connectors. This design is based only upon parameters shown, and is for an individual building component. Applicability of design parameters and proper incorporation of component is responsibility of building designer - not truss designer. Bracing shown is for lateral support of individual web members only. Additional temporary bracing to insure stability during construction is the responsibillity of theerector. Additional permanent bracing of the overall structure is the responsibility of the building designer. For general guidance regardingfabrication, quality control, storage, delivery, erection and bracing, consult 14515 N. Outer Forty, Suite #300
Chesterfield, MO 63017
ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 781 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information
February 12,2015
Job
1500058
Truss
PBB
Truss Type
SPECIAL
Qty
1
Ply
1
SOUTHILL C STANDARD
Job Reference (optional)
I23659143
7.430 s Jul 25 2013 MiTek Industries, Inc. Wed Feb 11 15:05:27 2015 Page 1 Timberland Lumber Company, Indianapolis, IN 46222
ID:6wSYySsChxEClNJ8ETXMjTzZ3cH-FGKzIFnFUDF?olt6cAinL7ycAIYYT3Khj7dsqDzmAbc
Scale = 1:12.8
Sheet Front
Full Sheathing
1 Ply 7/16" 4x8 OSB
12
3
4
5
3x4
2x4 2x4
0-0-3
0-0-3
3-6-6
3-6-3
3-6-10
0-0-3
1-9-5
1-9-5
3-6-10
1-9-5
0-5-102-0-140-1-100-5-100-1-1014.00 12
Plate Offsets (X,Y): [2:0-2-10,0-1-0], [3:Edge,0-3-1], [4:0-2-10,0-1-0]
LOADING (psf)
TCLL
(Roof Snow=20.0)
TCDL
BCLL
BCDL
20.0
10.0
0.0
10.0
SPACING
Plates Increase
Lumber Increase
Rep Stress Incr
Code
2-0-0
1.15
1.15
YES
IRC2006/TPI2002
CSI
TC
BC
WB
(Matrix)
0.03
0.07
0.00
DEFL
Vert(LL)
Vert(TL)
Horz(TL)
in
0.00
0.00
0.00
(loc)
4
4
4
l/defl
n/r
n/r
n/a
L/d
120
120
n/a
PLATES
MT20
Weight: 13 lb FT = 0%
GRIP
197/144
LUMBER
TOP CHORD 2x4 SPF No.2
BOT CHORD 2x4 SPF No.2
BRACING
TOP CHORD Structural wood sheathing directly applied or 3-6-10 oc purlins.
BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing.
MiTek recommends that Stabilizers and required cross bracing
be installed during truss erection, in accordance with Stabilizer
Installation guide.
REACTIONS (lb/size)2=120/2-6-3 (min. 0-1-8), 4=120/2-6-3 (min. 0-1-8)
Max Uplift2=-31(LC 6), 4=-31(LC 6)
FORCES (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
NOTES
1) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=30ft; Cat. II; Exp B; enclosed; C-C Exterior(2); cantilever left and right
exposed ; end vertical left and right exposed; Lumber DOL=1.33 plate grip DOL=1.33
2) TCLL: ASCE 7-05; Pf=20.0 psf (flat roof snow); Category II; Exp B; Fully Exp.; Ct=1.1
3) Unbalanced snow loads have been considered for this design.
4) This truss has been designed for greater of min roof live load of 12.0 psf or 2.00 times flat roof load of 20.0 psf on overhangs
non-concurrent with other live loads.
5) This truss has been designed for basic load combinations, which include cases with reductions for multiple concurrent live loads.
6) Gable requires continuous bottom chord bearing.
7) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
8) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 2, 4.
9) "Semi-rigid pitchbreaks including heels" Member end fixity model was used in the analysis and design of this truss.
10) See Standard Industry Piggyback Truss Connection Detail for Connection to base truss as applicable, or consult qualified building
designer.
11) Warning: Additional permanent and stability bracing for truss system (not part of this component design) is always required.
LOAD CASE(S) Standard
Design valid for use only with MiTek connectors. This design is based only upon parameters shown, and is for an individual building component. Applicability of design parameters and proper incorporation of component is responsibility of building designer - not truss designer. Bracing shown is for lateral support of individual web members only. Additional temporary bracing to insure stability during construction is the responsibillity of theerector. Additional permanent bracing of the overall structure is the responsibility of the building designer. For general guidance regardingfabrication, quality control, storage, delivery, erection and bracing, consult 14515 N. Outer Forty, Suite #300
Chesterfield, MO 63017
ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 781 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information
February 12,2015
Job
1500058
Truss
PBC
Truss Type
SPECIAL
Qty
1
Ply
1
SOUTHILL C STANDARD
Job Reference (optional)
I23659144
7.430 s Jul 25 2013 MiTek Industries, Inc. Wed Feb 11 15:05:27 2015 Page 1 Timberland Lumber Company, Indianapolis, IN 46222
ID:6wSYySsChxEClNJ8ETXMjTzZ3cH-FGKzIFnFUDF?olt6cAinL7ybcIYXT3Khj7dsqDzmAbc
Scale = 1:9.9
1
2
3
4
5
6
3x4 3x4
3x4 3x4
0-0-3
0-0-3
4-8-6
4-8-2
4-8-9
0-0-3
0-11-2
0-11-2
3-9-7
2-10-5
4-8-9
0-11-2
0-5-100-11-11-1-00-1-100-5-100-1-100-9-714.00 12
Plate Offsets (X,Y): [2:0-4-0,0-0-10], [3:0-2-2,0-1-8], [4:0-2-2,0-1-8], [5:0-4-0,0-0-10]
LOADING (psf)
TCLL
(Roof Snow=20.0)
TCDL
BCLL
BCDL
20.0
10.0
0.0
10.0
SPACING
Plates Increase
Lumber Increase
Rep Stress Incr
Code
2-0-0
1.15
1.15
YES
IRC2006/TPI2002
CSI
TC
BC
WB
(Matrix)
0.07
0.07
0.00
DEFL
Vert(LL)
Vert(TL)
Horz(TL)
in
-0.00
0.00
0.00
(loc)
5
5
5
l/defl
n/r
n/r
n/a
L/d
120
120
n/a
PLATES
MT20
Weight: 11 lb FT = 0%
GRIP
197/144
LUMBER
TOP CHORD 2x4 SPF No.2
BOT CHORD 2x4 SPF No.2
BRACING
TOP CHORD Structural wood sheathing directly applied or 4-8-9 oc purlins, except
2-0-0 oc purlins: 3-4.
BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing.
MiTek recommends that Stabilizers and required cross bracing
be installed during truss erection, in accordance with Stabilizer
Installation guide.
REACTIONS (lb/size)2=166/3-8-2 (min. 0-1-8), 5=166/3-8-2 (min. 0-1-8)
Max Uplift2=-54(LC 4), 5=-54(LC 4)
FORCES (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
NOTES
1) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=30ft; Cat. II; Exp B; enclosed; C-C Exterior(2); cantilever left and right
exposed ; end vertical left and right exposed; Lumber DOL=1.33 plate grip DOL=1.33
2) TCLL: ASCE 7-05; Pf=20.0 psf (flat roof snow); Category II; Exp B; Fully Exp.; Ct=1.1, Lu=50-0-0
3) This truss has been designed for greater of min roof live load of 12.0 psf or 2.00 times flat roof load of 20.0 psf on overhangs
non-concurrent with other live loads.
4) This truss has been designed for basic load combinations, which include cases with reductions for multiple concurrent live loads.
5) Provide adequate drainage to prevent water ponding.
6) Gable requires continuous bottom chord bearing.
7) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
8) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 2, 5.
9) "Semi-rigid pitchbreaks including heels" Member end fixity model was used in the analysis and design of this truss.
10) See Standard Industry Piggyback Truss Connection Detail for Connection to base truss as applicable, or consult qualified building
designer.
11) Graphical purlin representation does not depict the size or the orientation of the purlin along the top and/or bottom chord.
12) Warning: Additional permanent and stability bracing for truss system (not part of this component design) is always required.
LOAD CASE(S) Standard
Design valid for use only with MiTek connectors. This design is based only upon parameters shown, and is for an individual building component. Applicability of design parameters and proper incorporation of component is responsibility of building designer - not truss designer. Bracing shown is for lateral support of individual web members only. Additional temporary bracing to insure stability during construction is the responsibillity of theerector. Additional permanent bracing of the overall structure is the responsibility of the building designer. For general guidance regardingfabrication, quality control, storage, delivery, erection and bracing, consult 14515 N. Outer Forty, Suite #300
Chesterfield, MO 63017
ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 781 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information
February 12,2015
Job
1500058
Truss
V1
Truss Type
GABLE
Qty
1
Ply
1
SOUTHILL C STANDARD
Job Reference (optional)
I23659145
7.430 s Jul 25 2013 MiTek Industries, Inc. Wed Feb 11 15:05:28 2015 Page 1 Timberland Lumber Company, Indianapolis, IN 46222
ID:6wSYySsChxEClNJ8ETXMjTzZ3cH-jStLWbotEXNsQuSIAtE0tKVhYiovCRpqynMPNfzmAbb
Scale = 1:75.3
1
2
3
4
5
9 8 7 6
10 11
3x4
4x6
3x4
5x6 WB 2x4
2x4
2x4
2x4
20-4-14
20-4-14
10-2-7
10-2-7
20-4-14
10-2-7
11-10-1414.00 12
Plate Offsets (X,Y): [1:0-1-5,0-1-8], [3:Edge,0-1-14], [5:0-0-11,0-1-8], [8:0-3-0,0-0-4]
LOADING (psf)
TCLL
(Roof Snow=20.0)
TCDL
BCLL
BCDL
20.0
10.0
0.0
10.0
SPACING
Plates Increase
Lumber Increase
Rep Stress Incr
Code
2-0-0
1.15
1.15
YES
IRC2006/TPI2002
CSI
TC
BC
WB
(Matrix)
0.44
0.51
0.37
DEFL
Vert(LL)
Vert(TL)
Horz(TL)
in
n/a
n/a
0.01
(loc)
-
-
5
l/defl
n/a
n/a
n/a
L/d
999
999
n/a
PLATES
MT20
Weight: 86 lb FT = 0%
GRIP
197/144
LUMBER
TOP CHORD 2x4 SPF No.2
BOT CHORD 2x4 SPF No.2 *Except*
1-8: 2x4 SPF Stud/No.3
OTHERS 2x4 SPF Stud/No.3 *Except*
3-7: 2x4 SPF No.2
BRACING
TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins.
BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing.
WEBS 1 Row at midpt 3-7
MiTek recommends that Stabilizers and required cross bracing
be installed during truss erection, in accordance with Stabilizer
Installation guide.
REACTIONS All bearings 20-4-14.
(lb) - Max Uplift All uplift 100 lb or less at joint(s) except 9=-281(LC 6), 6=-281(LC 6)
Max Grav All reactions 250 lb or less at joint(s) 1, 5, 7 except 9=522(LC 7),
6=521(LC 8)
FORCES (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
WEBS 2-9=-382/334, 4-6=-380/333
NOTES
1) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=30ft; Cat. II; Exp B; enclosed; C-C Exterior(2); cantilever left and right
exposed ; end vertical left and right exposed; Lumber DOL=1.33 plate grip DOL=1.33
2) TCLL: ASCE 7-05; Pf=20.0 psf (flat roof snow); Category II; Exp B; Fully Exp.; Ct=1.1
3) Unbalanced snow loads have been considered for this design.
4) This truss has been designed for basic load combinations, which include cases with reductions for multiple concurrent live loads.
5) Gable requires continuous bottom chord bearing.
6) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 281 lb uplift at joint 9 and 281 lb uplift at
joint 6.
8) "Semi-rigid pitchbreaks including heels" Member end fixity model was used in the analysis and design of this truss.
9) Warning: Additional permanent and stability bracing for truss system (not part of this component design) is always required.
LOAD CASE(S) Standard
Design valid for use only with MiTek connectors. This design is based only upon parameters shown, and is for an individual building component. Applicability of design parameters and proper incorporation of component is responsibility of building designer - not truss designer. Bracing shown is for lateral support of individual web members only. Additional temporary bracing to insure stability during construction is the responsibillity of theerector. Additional permanent bracing of the overall structure is the responsibility of the building designer. For general guidance regardingfabrication, quality control, storage, delivery, erection and bracing, consult 14515 N. Outer Forty, Suite #300
Chesterfield, MO 63017
ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 781 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information
February 12,2015
Job
1500058
Truss
V2
Truss Type
GABLE
Qty
1
Ply
1
SOUTHILL C STANDARD
Job Reference (optional)
I23659146
7.430 s Jul 25 2013 MiTek Industries, Inc. Wed Feb 11 15:05:31 2015 Page 1 Timberland Lumber Company, Indianapolis, IN 46222
ID:6wSYySsChxEClNJ8ETXMjTzZ3cH-71ZU8dqlXSlRHMBtr?njVz7Etvr0PqqGelb3z_zmAbY
Scale = 1:70.8
1
2
3
4
5
9 8 7 6
10 11
3x4
4x6
3x4
3x4 2x4
2x4
2x4
2x4
2x4
18-4-14
18-4-14
9-2-7
9-2-7
18-4-14
9-2-7
10-8-1414.00 12
Plate Offsets (X,Y): [3:Edge,0-1-14]
LOADING (psf)
TCLL
(Roof Snow=20.0)
TCDL
BCLL
BCDL
20.0
10.0
0.0
10.0
SPACING
Plates Increase
Lumber Increase
Rep Stress Incr
Code
2-0-0
1.15
1.15
YES
IRC2006/TPI2002
CSI
TC
BC
WB
(Matrix)
0.31
0.36
0.22
DEFL
Vert(LL)
Vert(TL)
Horz(TL)
in
n/a
n/a
0.01
(loc)
-
-
5
l/defl
n/a
n/a
n/a
L/d
999
999
n/a
PLATES
MT20
Weight: 76 lb FT = 0%
GRIP
197/144
LUMBER
TOP CHORD 2x4 SPF No.2
BOT CHORD 2x4 SPF No.2 *Except*
1-8: 2x4 SPF Stud/No.3
OTHERS 2x4 SPF Stud/No.3 *Except*
3-7: 2x4 SPF No.2
BRACING
TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins.
BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing.
WEBS 1 Row at midpt 3-7
MiTek recommends that Stabilizers and required cross bracing
be installed during truss erection, in accordance with Stabilizer
Installation guide.
REACTIONS All bearings 18-4-14.
(lb) - Max Uplift All uplift 100 lb or less at joint(s) except 9=-253(LC 6), 6=-253(LC 6)
Max Grav All reactions 250 lb or less at joint(s) 1, 5, 7 except 9=447(LC 7),
6=447(LC 8)
FORCES (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
WEBS 2-9=-331/300, 4-6=-330/300
NOTES
1) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=30ft; Cat. II; Exp B; enclosed; C-C Exterior(2); cantilever left and right
exposed ; end vertical left and right exposed; Lumber DOL=1.33 plate grip DOL=1.33
2) TCLL: ASCE 7-05; Pf=20.0 psf (flat roof snow); Category II; Exp B; Fully Exp.; Ct=1.1
3) Unbalanced snow loads have been considered for this design.
4) This truss has been designed for basic load combinations, which include cases with reductions for multiple concurrent live loads.
5) Gable requires continuous bottom chord bearing.
6) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 253 lb uplift at joint 9 and 253 lb uplift at
joint 6.
8) "Semi-rigid pitchbreaks including heels" Member end fixity model was used in the analysis and design of this truss.
9) Warning: Additional permanent and stability bracing for truss system (not part of this component design) is always required.
LOAD CASE(S) Standard
Design valid for use only with MiTek connectors. This design is based only upon parameters shown, and is for an individual building component. Applicability of design parameters and proper incorporation of component is responsibility of building designer - not truss designer. Bracing shown is for lateral support of individual web members only. Additional temporary bracing to insure stability during construction is the responsibillity of theerector. Additional permanent bracing of the overall structure is the responsibility of the building designer. For general guidance regardingfabrication, quality control, storage, delivery, erection and bracing, consult 14515 N. Outer Forty, Suite #300
Chesterfield, MO 63017
ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 781 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information
February 12,2015
Job
1500058
Truss
V3
Truss Type
GABLE
Qty
1
Ply
1
SOUTHILL C STANDARD
Job Reference (optional)
I23659147
7.430 s Jul 25 2013 MiTek Industries, Inc. Wed Feb 11 15:05:31 2015 Page 1 Timberland Lumber Company, Indianapolis, IN 46222
ID:6wSYySsChxEClNJ8ETXMjTzZ3cH-71ZU8dqlXSlRHMBtr?njVz7GwvujPrIGelb3z_zmAbY
Scale = 1:60.5
1
2
3
4
5
9 8 7 6
10 11
3x4
4x6
3x4
3x4 2x4 2x4
2x4
2x4
2x4
16-4-14
16-4-14
8-2-7
8-2-7
16-4-14
8-2-7
9-6-1414.00 12
Plate Offsets (X,Y): [3:Edge,0-1-14]
LOADING (psf)
TCLL
(Roof Snow=20.0)
TCDL
BCLL
BCDL
20.0
10.0
0.0
10.0
SPACING
Plates Increase
Lumber Increase
Rep Stress Incr
Code
2-0-0
1.15
1.15
YES
IRC2006/TPI2002
CSI
TC
BC
WB
(Matrix)
0.18
0.18
0.13
DEFL
Vert(LL)
Vert(TL)
Horz(TL)
in
n/a
n/a
0.00
(loc)
-
-
5
l/defl
n/a
n/a
n/a
L/d
999
999
n/a
PLATES
MT20
Weight: 67 lb FT = 0%
GRIP
197/144
LUMBER
TOP CHORD 2x4 SPF No.2
BOT CHORD 2x4 SPF No.2 *Except*
1-8: 2x4 SPF Stud/No.3
OTHERS 2x4 SPF Stud/No.3 *Except*
3-7: 2x4 SPF No.2
BRACING
TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins.
BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing.
WEBS 1 Row at midpt 3-7
MiTek recommends that Stabilizers and required cross bracing
be installed during truss erection, in accordance with Stabilizer
Installation guide.
REACTIONS All bearings 16-4-14.
(lb) - Max Uplift All uplift 100 lb or less at joint(s) except 9=-229(LC 6), 6=-229(LC 6)
Max Grav All reactions 250 lb or less at joint(s) 1, 5, 7 except 9=383(LC 7),
6=383(LC 8)
FORCES (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
WEBS 2-9=-288/271, 4-6=-287/271
NOTES
1) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=30ft; Cat. II; Exp B; enclosed; C-C Exterior(2); cantilever left and right
exposed ; end vertical left and right exposed; Lumber DOL=1.33 plate grip DOL=1.33
2) TCLL: ASCE 7-05; Pf=20.0 psf (flat roof snow); Category II; Exp B; Fully Exp.; Ct=1.1
3) Unbalanced snow loads have been considered for this design.
4) This truss has been designed for basic load combinations, which include cases with reductions for multiple concurrent live loads.
5) Gable requires continuous bottom chord bearing.
6) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 229 lb uplift at joint 9 and 229 lb uplift at
joint 6.
8) "Semi-rigid pitchbreaks including heels" Member end fixity model was used in the analysis and design of this truss.
9) Warning: Additional permanent and stability bracing for truss system (not part of this component design) is always required.
LOAD CASE(S) Standard
Design valid for use only with MiTek connectors. This design is based only upon parameters shown, and is for an individual building component. Applicability of design parameters and proper incorporation of component is responsibility of building designer - not truss designer. Bracing shown is for lateral support of individual web members only. Additional temporary bracing to insure stability during construction is the responsibillity of theerector. Additional permanent bracing of the overall structure is the responsibility of the building designer. For general guidance regardingfabrication, quality control, storage, delivery, erection and bracing, consult 14515 N. Outer Forty, Suite #300
Chesterfield, MO 63017
ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 781 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information
February 12,2015
Job
1500058
Truss
V4
Truss Type
GABLE
Qty
1
Ply
1
SOUTHILL C STANDARD
Job Reference (optional)
I23659148
7.430 s Jul 25 2013 MiTek Industries, Inc. Wed Feb 11 15:05:32 2015 Page 1 Timberland Lumber Company, Indianapolis, IN 46222
ID:6wSYySsChxEClNJ8ETXMjTzZ3cH-cE7sLzrOImtIuWm4PjIy2AgQLJFP8I4QsPKdWRzmAbX
Scale = 1:55.6
1
2
3
4
5
8 7 6
9 10
3x4
4x6
3x4 2x4 2x4
2x4
2x4
2x4
14-4-14
14-4-14
7-2-7
7-2-7
14-4-14
7-2-7
8-4-1414.00 12
Plate Offsets (X,Y): [3:Edge,0-1-14]
LOADING (psf)
TCLL
(Roof Snow=20.0)
TCDL
BCLL
BCDL
20.0
10.0
0.0
10.0
SPACING
Plates Increase
Lumber Increase
Rep Stress Incr
Code
2-0-0
1.15
1.15
YES
IRC2006/TPI2002
CSI
TC
BC
WB
(Matrix)
0.20
0.09
0.16
DEFL
Vert(LL)
Vert(TL)
Horz(TL)
in
n/a
n/a
0.00
(loc)
-
-
5
l/defl
n/a
n/a
n/a
L/d
999
999
n/a
PLATES
MT20
Weight: 57 lb FT = 0%
GRIP
197/144
LUMBER
TOP CHORD 2x4 SPF No.2
BOT CHORD 2x4 SPF No.2
OTHERS 2x4 SPF Stud/No.3
BRACING
TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins.
BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing.
MiTek recommends that Stabilizers and required cross bracing
be installed during truss erection, in accordance with Stabilizer
Installation guide.
REACTIONS All bearings 14-4-14.
(lb) - Max Uplift All uplift 100 lb or less at joint(s) except 8=-209(LC 6), 6=-209(LC 6)
Max Grav All reactions 250 lb or less at joint(s) 1, 5, 7 except 8=331(LC 7), 6=331(LC 8)
FORCES (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
WEBS 2-8=-253/249, 4-6=-253/249
NOTES
1) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=30ft; Cat. II; Exp B; enclosed; C-C Exterior(2); cantilever left and right
exposed ; end vertical left and right exposed; Lumber DOL=1.33 plate grip DOL=1.33
2) TCLL: ASCE 7-05; Pf=20.0 psf (flat roof snow); Category II; Exp B; Fully Exp.; Ct=1.1
3) Unbalanced snow loads have been considered for this design.
4) This truss has been designed for basic load combinations, which include cases with reductions for multiple concurrent live loads.
5) Gable requires continuous bottom chord bearing.
6) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 209 lb uplift at joint 8 and 209 lb uplift at
joint 6.
8) "Semi-rigid pitchbreaks including heels" Member end fixity model was used in the analysis and design of this truss.
9) Warning: Additional permanent and stability bracing for truss system (not part of this component design) is always required.
LOAD CASE(S) Standard
Design valid for use only with MiTek connectors. This design is based only upon parameters shown, and is for an individual building component. Applicability of design parameters and proper incorporation of component is responsibility of building designer - not truss designer. Bracing shown is for lateral support of individual web members only. Additional temporary bracing to insure stability during construction is the responsibillity of theerector. Additional permanent bracing of the overall structure is the responsibility of the building designer. For general guidance regardingfabrication, quality control, storage, delivery, erection and bracing, consult 14515 N. Outer Forty, Suite #300
Chesterfield, MO 63017
ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 781 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information
February 12,2015
Job
1500058
Truss
V5
Truss Type
GABLE
Qty
1
Ply
1
SOUTHILL C STANDARD
Job Reference (optional)
I23659149
7.430 s Jul 25 2013 MiTek Industries, Inc. Wed Feb 11 15:05:32 2015 Page 1 Timberland Lumber Company, Indianapolis, IN 46222
ID:6wSYySsChxEClNJ8ETXMjTzZ3cH-cE7sLzrOImtIuWm4PjIy2AgPuJAp8HUQsPKdWRzmAbX
Scale: 1/4"=1’
1
2
3
4
5 6
3x6
4x6
3x6
2x4
12-4-14
12-4-14
6-2-7
6-2-7
12-4-14
6-2-7
7-2-1414.00 12
Plate Offsets (X,Y): [2:Edge,0-1-14]
LOADING (psf)
TCLL
(Roof Snow=20.0)
TCDL
BCLL
BCDL
20.0
10.0
0.0
10.0
SPACING
Plates Increase
Lumber Increase
Rep Stress Incr
Code
2-0-0
1.15
1.15
YES
IRC2006/TPI2002
CSI
TC
BC
WB
(Matrix)
0.29
0.38
0.20
DEFL
Vert(LL)
Vert(TL)
Horz(TL)
in
n/a
n/a
0.00
(loc)
-
-
3
l/defl
n/a
n/a
n/a
L/d
999
999
n/a
PLATES
MT20
Weight: 42 lb FT = 0%
GRIP
197/144
LUMBER
TOP CHORD 2x4 SPF No.2
BOT CHORD 2x4 SPF No.2
OTHERS 2x4 SPF Stud/No.3
BRACING
TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins.
BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing.
MiTek recommends that Stabilizers and required cross bracing
be installed during truss erection, in accordance with Stabilizer
Installation guide.
REACTIONS (lb/size)1=280/12-4-14 (min. 0-1-8), 3=280/12-4-14 (min. 0-1-8), 4=382/12-4-14 (min. 0-1-8)
Max Uplift1=-53(LC 6), 3=-53(LC 6)
FORCES (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
NOTES
1) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=30ft; Cat. II; Exp B; enclosed; C-C Exterior(2); cantilever left and right
exposed ; end vertical left and right exposed; Lumber DOL=1.33 plate grip DOL=1.33
2) TCLL: ASCE 7-05; Pf=20.0 psf (flat roof snow); Category II; Exp B; Fully Exp.; Ct=1.1
3) Unbalanced snow loads have been considered for this design.
4) This truss has been designed for basic load combinations, which include cases with reductions for multiple concurrent live loads.
5) Gable requires continuous bottom chord bearing.
6) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 53 lb uplift at joint 1 and 53 lb uplift at joint
3.
8) "Semi-rigid pitchbreaks including heels" Member end fixity model was used in the analysis and design of this truss.
9) Warning: Additional permanent and stability bracing for truss system (not part of this component design) is always required.
LOAD CASE(S) Standard
Design valid for use only with MiTek connectors. This design is based only upon parameters shown, and is for an individual building component. Applicability of design parameters and proper incorporation of component is responsibility of building designer - not truss designer. Bracing shown is for lateral support of individual web members only. Additional temporary bracing to insure stability during construction is the responsibillity of theerector. Additional permanent bracing of the overall structure is the responsibility of the building designer. For general guidance regardingfabrication, quality control, storage, delivery, erection and bracing, consult 14515 N. Outer Forty, Suite #300
Chesterfield, MO 63017
ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 781 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information
February 12,2015
Job
1500058
Truss
V6
Truss Type
GABLE
Qty
1
Ply
1
SOUTHILL C STANDARD
Job Reference (optional)
I23659150
7.430 s Jul 25 2013 MiTek Industries, Inc. Wed Feb 11 15:05:33 2015 Page 1 Timberland Lumber Company, Indianapolis, IN 46222
ID:6wSYySsChxEClNJ8ETXMjTzZ3cH-4QhEZIs03309WgLGzQpBaOCZmjYttmyZ534A2tzmAbW
Scale = 1:40.7
1
2
3
4
5 6
2x8
4x6
2x8
2x4
10-4-14
10-4-14
5-2-7
5-2-7
10-4-14
5-2-7
6-0-1414.00 12
Plate Offsets (X,Y): [1:0-4-4,0-1-0], [2:Edge,0-1-14], [3:0-4-4,0-1-0]
LOADING (psf)
TCLL
(Roof Snow=20.0)
TCDL
BCLL
BCDL
20.0
10.0
0.0
10.0
SPACING
Plates Increase
Lumber Increase
Rep Stress Incr
Code
2-0-0
1.15
1.15
YES
IRC2006/TPI2002
CSI
TC
BC
WB
(Matrix)
0.35
0.27
0.12
DEFL
Vert(LL)
Vert(TL)
Horz(TL)
in
n/a
n/a
0.00
(loc)
-
-
3
l/defl
n/a
n/a
n/a
L/d
999
999
n/a
PLATES
MT20
Weight: 35 lb FT = 0%
GRIP
197/144
LUMBER
TOP CHORD 2x4 SPF Stud/No.3
BOT CHORD 2x4 SPF No.2
OTHERS 2x4 SPF Stud/No.3
BRACING
TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins.
BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing.
MiTek recommends that Stabilizers and required cross bracing
be installed during truss erection, in accordance with Stabilizer
Installation guide.
REACTIONS (lb/size)1=227/10-4-14 (min. 0-1-8), 3=227/10-4-14 (min. 0-1-8), 4=327/10-4-14 (min. 0-1-8)
Max Uplift1=-45(LC 6), 3=-45(LC 6), 4=-8(LC 6)
FORCES (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
NOTES
1) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=30ft; Cat. II; Exp B; enclosed; C-C Exterior(2); cantilever left and right
exposed ; end vertical left and right exposed; Lumber DOL=1.33 plate grip DOL=1.33
2) TCLL: ASCE 7-05; Pf=20.0 psf (flat roof snow); Category II; Exp B; Fully Exp.; Ct=1.1
3) Unbalanced snow loads have been considered for this design.
4) This truss has been designed for basic load combinations, which include cases with reductions for multiple concurrent live loads.
5) Gable requires continuous bottom chord bearing.
6) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 45 lb uplift at joint 1, 45 lb uplift at joint 3
and 8 lb uplift at joint 4.
8) "Semi-rigid pitchbreaks including heels" Member end fixity model was used in the analysis and design of this truss.
9) Warning: Additional permanent and stability bracing for truss system (not part of this component design) is always required.
LOAD CASE(S) Standard
Design valid for use only with MiTek connectors. This design is based only upon parameters shown, and is for an individual building component. Applicability of design parameters and proper incorporation of component is responsibility of building designer - not truss designer. Bracing shown is for lateral support of individual web members only. Additional temporary bracing to insure stability during construction is the responsibillity of theerector. Additional permanent bracing of the overall structure is the responsibility of the building designer. For general guidance regardingfabrication, quality control, storage, delivery, erection and bracing, consult 14515 N. Outer Forty, Suite #300
Chesterfield, MO 63017
ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 781 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information
February 12,2015
Job
1500058
Truss
V7
Truss Type
VALLEY
Qty
1
Ply
1
SOUTHILL C STANDARD
Job Reference (optional)
I23659151
7.430 s Jul 25 2013 MiTek Industries, Inc. Wed Feb 11 15:05:33 2015 Page 1 Timberland Lumber Company, Indianapolis, IN 46222
ID:6wSYySsChxEClNJ8ETXMjTzZ3cH-4QhEZIs03309WgLGzQpBaOCXdjaStnsZ534A2tzmAbW
Scale = 1:34.4
1
2
3
4
5 6
2x4
4x6
2x4
2x4
8-4-14
8-4-14
4-2-7
4-2-7
8-4-14
4-2-7
4-10-1414.00 12
Plate Offsets (X,Y): [2:Edge,0-1-14]
LOADING (psf)
TCLL
(Roof Snow=20.0)
TCDL
BCLL
BCDL
20.0
10.0
0.0
10.0
SPACING
Plates Increase
Lumber Increase
Rep Stress Incr
Code
2-0-0
1.15
1.15
YES
IRC2006/TPI2002
CSI
TC
BC
WB
(Matrix)
0.49
0.17
0.06
DEFL
Vert(LL)
Vert(TL)
Horz(TL)
in
n/a
n/a
0.00
(loc)
-
-
3
l/defl
n/a
n/a
n/a
L/d
999
999
n/a
PLATES
MT20
Weight: 28 lb FT = 0%
GRIP
197/144
LUMBER
TOP CHORD 2x4 SPF Stud/No.3
BOT CHORD 2x4 SPF No.2
OTHERS 2x4 SPF Stud/No.3
BRACING
TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins.
BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing.
MiTek recommends that Stabilizers and required cross bracing
be installed during truss erection, in accordance with Stabilizer
Installation guide.
REACTIONS (lb/size)1=194/8-4-14 (min. 0-1-8), 3=194/8-4-14 (min. 0-1-8), 4=234/8-4-14 (min. 0-1-8)
Max Uplift1=-58(LC 6), 3=-58(LC 6)
Max Grav 1=194(LC 1), 3=194(LC 1), 4=240(LC 5)
FORCES (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
NOTES
1) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=30ft; Cat. II; Exp B; enclosed; C-C Exterior(2); cantilever left and right
exposed ; end vertical left and right exposed; Lumber DOL=1.33 plate grip DOL=1.33
2) TCLL: ASCE 7-05; Pf=20.0 psf (flat roof snow); Category II; Exp B; Fully Exp.; Ct=1.1
3) Unbalanced snow loads have been considered for this design.
4) This truss has been designed for basic load combinations, which include cases with reductions for multiple concurrent live loads.
5) Gable requires continuous bottom chord bearing.
6) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 58 lb uplift at joint 1 and 58 lb uplift at joint
3.
8) "Semi-rigid pitchbreaks including heels" Member end fixity model was used in the analysis and design of this truss.
9) Warning: Additional permanent and stability bracing for truss system (not part of this component design) is always required.
LOAD CASE(S) Standard
Design valid for use only with MiTek connectors. This design is based only upon parameters shown, and is for an individual building component. Applicability of design parameters and proper incorporation of component is responsibility of building designer - not truss designer. Bracing shown is for lateral support of individual web members only. Additional temporary bracing to insure stability during construction is the responsibillity of theerector. Additional permanent bracing of the overall structure is the responsibility of the building designer. For general guidance regardingfabrication, quality control, storage, delivery, erection and bracing, consult 14515 N. Outer Forty, Suite #300
Chesterfield, MO 63017
ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 781 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information
February 12,2015
Job
1500058
Truss
V8
Truss Type
VALLEY
Qty
1
Ply
1
SOUTHILL C STANDARD
Job Reference (optional)
I23659152
7.430 s Jul 25 2013 MiTek Industries, Inc. Wed Feb 11 15:05:33 2015 Page 1 Timberland Lumber Company, Indianapolis, IN 46222
ID:6wSYySsChxEClNJ8ETXMjTzZ3cH-4QhEZIs03309WgLGzQpBaOCapjY1tnpZ534A2tzmAbW
Scale = 1:16.6
1
2
3
4
5
6
2x8
3x4 3x4
2x8
6-4-14
6-4-14
2-2-2
2-2-2
4-2-12
2-0-10
6-4-14
2-2-2
2-4-122-6-82-4-1214.00 12
Plate Offsets (X,Y): [1:0-4-4,0-1-0], [2:0-2-5,0-1-8], [3:0-2-5,0-1-8], [4:0-4-4,0-1-0]
LOADING (psf)
TCLL
(Roof Snow=20.0)
TCDL
BCLL
BCDL
20.0
10.0
0.0
10.0
SPACING
Plates Increase
Lumber Increase
Rep Stress Incr
Code
2-0-0
1.15
1.15
YES
IRC2006/TPI2002
CSI
TC
BC
WB
(Matrix)
0.28
0.26
0.00
DEFL
Vert(LL)
Vert(TL)
Horz(TL)
in
n/a
n/a
0.00
(loc)
-
-
4
l/defl
n/a
n/a
n/a
L/d
999
999
n/a
PLATES
MT20
Weight: 16 lb FT = 0%
GRIP
197/144
LUMBER
TOP CHORD 2x4 SPF No.2
BOT CHORD 2x4 SPF No.2
BRACING
TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except
2-0-0 oc purlins (6-0-0 max.): 2-3.
BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing.
MiTek recommends that Stabilizers and required cross bracing
be installed during truss erection, in accordance with Stabilizer
Installation guide.
REACTIONS (lb/size)1=231/6-4-14 (min. 0-1-8), 4=231/6-4-14 (min. 0-1-8)
Max Uplift1=-49(LC 6), 4=-49(LC 6)
Max Grav 1=326(LC 15), 4=326(LC 15)
FORCES (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
TOP CHORD 1-2=-294/82, 3-4=-294/82
NOTES
1) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=30ft; Cat. II; Exp B; enclosed; C-C Exterior(2); cantilever left and right
exposed ; end vertical left and right exposed; Lumber DOL=1.33 plate grip DOL=1.33
2) TCLL: ASCE 7-05; Pf=20.0 psf (flat roof snow); Category II; Exp B; Fully Exp.; Ct=1.1, Lu=50-0-0
3) Unbalanced snow loads have been considered for this design.
4) This truss has been designed for basic load combinations, which include cases with reductions for multiple concurrent live loads.
5) Provide adequate drainage to prevent water ponding.
6) Gable requires continuous bottom chord bearing.
7) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
8) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 49 lb uplift at joint 1 and 49 lb uplift at joint
4.
9) "Semi-rigid pitchbreaks including heels" Member end fixity model was used in the analysis and design of this truss.
10) Graphical purlin representation does not depict the size or the orientation of the purlin along the top and/or bottom chord.
11) Warning: Additional permanent and stability bracing for truss system (not part of this component design) is always required.
LOAD CASE(S) Standard
Design valid for use only with MiTek connectors. This design is based only upon parameters shown, and is for an individual building component. Applicability of design parameters and proper incorporation of component is responsibility of building designer - not truss designer. Bracing shown is for lateral support of individual web members only. Additional temporary bracing to insure stability during construction is the responsibillity of theerector. Additional permanent bracing of the overall structure is the responsibility of the building designer. For general guidance regardingfabrication, quality control, storage, delivery, erection and bracing, consult 14515 N. Outer Forty, Suite #300
Chesterfield, MO 63017
ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 781 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information
February 12,2015
Job
1500058
Truss
V9
Truss Type
GABLE
Qty
1
Ply
1
SOUTHILL C STANDARD
Job Reference (optional)
I23659153
7.430 s Jul 25 2013 MiTek Industries, Inc. Wed Feb 11 15:05:34 2015 Page 1 Timberland Lumber Company, Indianapolis, IN 46222
ID:6wSYySsChxEClNJ8ETXMjTzZ3cH-YcFcmeteqN808pvSX8KQ7blgF6t5cDCjKjpkaJzmAbV
Scale = 1:26.7
1
2
3
4
5 6
3x6
4x9
3x6
2x4
13-10-4
13-10-4
6-11-2
6-11-2
13-10-4
6-11-2
4-0-87.00 12
LOADING (psf)
TCLL
(Roof Snow=20.0)
TCDL
BCLL
BCDL
20.0
10.0
0.0
10.0
SPACING
Plates Increase
Lumber Increase
Rep Stress Incr
Code
2-0-0
1.15
1.15
YES
IRC2006/TPI2002
CSI
TC
BC
WB
(Matrix)
0.62
0.33
0.12
DEFL
Vert(LL)
Vert(TL)
Horz(TL)
in
n/a
n/a
0.00
(loc)
-
-
3
l/defl
n/a
n/a
n/a
L/d
999
999
n/a
PLATES
MT20
Weight: 37 lb FT = 0%
GRIP
197/144
LUMBER
TOP CHORD 2x4 SPF No.2
BOT CHORD 2x4 SPF No.2
OTHERS 2x4 SPF Stud/No.3
BRACING
TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins.
BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing.
MiTek recommends that Stabilizers and required cross bracing
be installed during truss erection, in accordance with Stabilizer
Installation guide.
REACTIONS (lb/size)1=241/13-10-4 (min. 0-1-10), 3=241/13-10-4 (min. 0-1-10), 4=540/13-10-4 (min. 0-1-10)
Max Uplift1=-34(LC 6), 3=-34(LC 6), 4=-10(LC 6)
Max Grav 1=245(LC 7), 3=245(LC 8), 4=540(LC 1)
FORCES (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
WEBS 2-4=-349/84
NOTES
1) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=30ft; Cat. II; Exp B; enclosed; C-C Exterior(2); cantilever left and right
exposed ; end vertical left and right exposed; Lumber DOL=1.33 plate grip DOL=1.33
2) TCLL: ASCE 7-05; Pf=20.0 psf (flat roof snow); Category II; Exp B; Fully Exp.; Ct=1.1
3) Unbalanced snow loads have been considered for this design.
4) This truss has been designed for basic load combinations, which include cases with reductions for multiple concurrent live loads.
5) Gable requires continuous bottom chord bearing.
6) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 34 lb uplift at joint 1, 34 lb uplift at joint 3
and 10 lb uplift at joint 4.
8) "Semi-rigid pitchbreaks including heels" Member end fixity model was used in the analysis and design of this truss.
9) Warning: Additional permanent and stability bracing for truss system (not part of this component design) is always required.
LOAD CASE(S) Standard
Design valid for use only with MiTek connectors. This design is based only upon parameters shown, and is for an individual building component. Applicability of design parameters and proper incorporation of component is responsibility of building designer - not truss designer. Bracing shown is for lateral support of individual web members only. Additional temporary bracing to insure stability during construction is the responsibillity of theerector. Additional permanent bracing of the overall structure is the responsibility of the building designer. For general guidance regardingfabrication, quality control, storage, delivery, erection and bracing, consult 14515 N. Outer Forty, Suite #300
Chesterfield, MO 63017
ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 781 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information
February 12,2015
Job
1500058
Truss
V10
Truss Type
VALLEY
Qty
1
Ply
1
SOUTHILL C STANDARD
Job Reference (optional)
I23659154
7.430 s Jul 25 2013 MiTek Industries, Inc. Wed Feb 11 15:05:28 2015 Page 1 Timberland Lumber Company, Indianapolis, IN 46222
ID:6wSYySsChxEClNJ8ETXMjTzZ3cH-jStLWbotEXNsQuSIAtE0tKVj_itOCWdqynMPNfzmAbb
Scale = 1:20.2
1
2
3
4
5 6
2x8
4x6
2x8 2x4
9-10-4
9-10-4
4-11-2
4-11-2
9-10-4
4-11-2
2-10-87.00 12
LOADING (psf)
TCLL
(Roof Snow=20.0)
TCDL
BCLL
BCDL
20.0
10.0
0.0
10.0
SPACING
Plates Increase
Lumber Increase
Rep Stress Incr
Code
2-0-0
1.15
1.15
YES
IRC2006/TPI2002
CSI
TC
BC
WB
(Matrix)
0.29
0.16
0.06
DEFL
Vert(LL)
Vert(TL)
Horz(TL)
in
n/a
n/a
0.00
(loc)
-
-
3
l/defl
n/a
n/a
n/a
L/d
999
999
n/a
PLATES
MT20
Weight: 25 lb FT = 0%
GRIP
197/144
LUMBER
TOP CHORD 2x4 SPF Stud/No.3
BOT CHORD 2x4 SPF No.2
OTHERS 2x4 SPF Stud/No.3
BRACING
TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins.
BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing.
MiTek recommends that Stabilizers and required cross bracing
be installed during truss erection, in accordance with Stabilizer
Installation guide.
REACTIONS (lb/size)1=166/9-10-4 (min. 0-1-8), 3=166/9-10-4 (min. 0-1-8), 4=371/9-10-4 (min. 0-1-8)
Max Uplift1=-27(LC 6), 3=-27(LC 6), 4=-13(LC 6)
Max Grav 1=166(LC 7), 3=166(LC 8), 4=371(LC 1)
FORCES (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
NOTES
1) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=30ft; Cat. II; Exp B; enclosed; C-C Exterior(2); cantilever left and right
exposed ; end vertical left and right exposed; Lumber DOL=1.33 plate grip DOL=1.33
2) TCLL: ASCE 7-05; Pf=20.0 psf (flat roof snow); Category II; Exp B; Fully Exp.; Ct=1.1
3) Unbalanced snow loads have been considered for this design.
4) This truss has been designed for basic load combinations, which include cases with reductions for multiple concurrent live loads.
5) Gable requires continuous bottom chord bearing.
6) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 27 lb uplift at joint 1, 27 lb uplift at joint 3
and 13 lb uplift at joint 4.
8) "Semi-rigid pitchbreaks including heels" Member end fixity model was used in the analysis and design of this truss.
9) Warning: Additional permanent and stability bracing for truss system (not part of this component design) is always required.
LOAD CASE(S) Standard
Design valid for use only with MiTek connectors. This design is based only upon parameters shown, and is for an individual building component. Applicability of design parameters and proper incorporation of component is responsibility of building designer - not truss designer. Bracing shown is for lateral support of individual web members only. Additional temporary bracing to insure stability during construction is the responsibillity of theerector. Additional permanent bracing of the overall structure is the responsibility of the building designer. For general guidance regardingfabrication, quality control, storage, delivery, erection and bracing, consult 14515 N. Outer Forty, Suite #300
Chesterfield, MO 63017
ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 781 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information
February 12,2015
Job
1500058
Truss
V11
Truss Type
VALLEY
Qty
1
Ply
1
SOUTHILL C STANDARD
Job Reference (optional)
I23659155
7.430 s Jul 25 2013 MiTek Industries, Inc. Wed Feb 11 15:05:28 2015 Page 1 Timberland Lumber Company, Indianapolis, IN 46222
ID:6wSYySsChxEClNJ8ETXMjTzZ3cH-jStLWbotEXNsQuSIAtE0tKVlniooCWaqynMPNfzmAbb
Scale = 1:13.4
1
2
3
2x4
3x4
2x4
5-10-4
5-10-4
2-11-2
2-11-2
5-10-4
2-11-2
1-8-87.00 12
Plate Offsets (X,Y): [2:0-2-0,Edge]
LOADING (psf)
TCLL
(Roof Snow=20.0)
TCDL
BCLL
BCDL
20.0
10.0
0.0
10.0
SPACING
Plates Increase
Lumber Increase
Rep Stress Incr
Code
2-0-0
1.15
1.15
YES
IRC2006/TPI2002
CSI
TC
BC
WB
(Matrix)
0.17
0.45
0.00
DEFL
Vert(LL)
Vert(TL)
Horz(TL)
in
n/a
n/a
0.00
(loc)
-
-
3
l/defl
n/a
n/a
n/a
L/d
999
999
n/a
PLATES
MT20
Weight: 13 lb FT = 0%
GRIP
197/144
LUMBER
TOP CHORD 2x4 SPF Stud/No.3
BOT CHORD 2x4 SPF Stud/No.3
BRACING
TOP CHORD Structural wood sheathing directly applied or 5-10-4 oc purlins.
BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing.
MiTek recommends that Stabilizers and required cross bracing
be installed during truss erection, in accordance with Stabilizer
Installation guide.
REACTIONS (lb/size)1=191/5-10-4 (min. 0-1-8), 3=191/5-10-4 (min. 0-1-8)
Max Uplift1=-23(LC 6), 3=-23(LC 6)
FORCES (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
NOTES
1) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=30ft; Cat. II; Exp B; enclosed; C-C Exterior(2); cantilever left and right
exposed ; end vertical left and right exposed; Lumber DOL=1.33 plate grip DOL=1.33
2) TCLL: ASCE 7-05; Pf=20.0 psf (flat roof snow); Category II; Exp B; Fully Exp.; Ct=1.1
3) Unbalanced snow loads have been considered for this design.
4) This truss has been designed for basic load combinations, which include cases with reductions for multiple concurrent live loads.
5) Gable requires continuous bottom chord bearing.
6) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 23 lb uplift at joint 1 and 23 lb uplift at joint
3.
8) "Semi-rigid pitchbreaks including heels" Member end fixity model was used in the analysis and design of this truss.
9) Warning: Additional permanent and stability bracing for truss system (not part of this component design) is always required.
LOAD CASE(S) Standard
Design valid for use only with MiTek connectors. This design is based only upon parameters shown, and is for an individual building component. Applicability of design parameters and proper incorporation of component is responsibility of building designer - not truss designer. Bracing shown is for lateral support of individual web members only. Additional temporary bracing to insure stability during construction is the responsibillity of theerector. Additional permanent bracing of the overall structure is the responsibility of the building designer. For general guidance regardingfabrication, quality control, storage, delivery, erection and bracing, consult 14515 N. Outer Forty, Suite #300
Chesterfield, MO 63017
ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 781 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information
February 12,2015
Job
1500058
Truss
V12
Truss Type
GABLE
Qty
1
Ply
1
SOUTHILL C STANDARD
Job Reference (optional)
I23659156
7.430 s Jul 25 2013 MiTek Industries, Inc. Wed Feb 11 15:05:30 2015 Page 1 Timberland Lumber Company, Indianapolis, IN 46222
ID:6wSYySsChxEClNJ8ETXMjTzZ3cH-fr?6xHq7m8dafCchIIGUyla2MVYEgI87P5rWRYzmAbZ
Scale = 1:66.8
Sheet Front
Left Option 7-10-1
1 Ply 7/16" 4x8 OSB
1
2
3
4
5
6
7
8
9 10 11 12 13
14
15
16
17
18
31 30 29 28 27 26 25 24 23 22 21 20 19
32
35
33
36
34
38
40
39 37
41
42
43
44
3x4 3x4
4x6
3x4
4x6
7-10-1
7-10-1
21-4-0
13-5-15
-1-3-4
1-3-4
8-10-11
8-10-11
12-5-5
3-6-10
14-10-4
2-4-15
21-4-0
6-5-12
22-7-4
1-3-4
0-7-811-0-00-7-811-0-014.00 12
Plate Offsets (X,Y): [9:0-1-5,Edge], [13:0-1-5,Edge]
LOADING (psf)
TCLL
(Roof Snow=20.0)
TCDL
BCLL
BCDL
20.0
10.0
0.0
10.0
SPACING
Plates Increase
Lumber Increase
Rep Stress Incr
Code
2-0-0
1.15
1.15
YES
IRC2006/TPI2002
CSI
TC
BC
WB
(Matrix)
0.36
0.14
0.57
DEFL
Vert(LL)
Vert(TL)
Horz(TL)
in
-0.00
-0.01
0.01
(loc)
18
18
17
l/defl
n/r
n/r
n/a
L/d
120
120
n/a
PLATES
MT20
Weight: 280 lb FT = 0%
GRIP
197/144
LUMBER
TOP CHORD 2x4 SPF No.2 *Except*
9-13: 2x4 SPF Stud/No.3
BOT CHORD 2x4 SPF No.2 *Except*
2-26: 2x4 SPF Stud/No.3
WEBS 2x4 SPF Stud/No.3
OTHERS 2x4 SPF Stud/No.3 *Except*
10-24,8-25,12-22,14-21: 2x4 SPF No.2
WEDGE
Left: 2x4 SPF Stud/No.3, Right: 2x4 SPF Stud/No.3
BRACING
TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except
2-0-0 oc purlins (6-0-0 max.): 9-13.
BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing.
WEBS 1 Row at midpt 8-25, 14-21
JOINTS 1 Brace at Jt(s): 32, 33, 34, 35, 36
MiTek recommends that Stabilizers and required cross bracing
be installed during truss erection, in accordance with Stabilizer
Installation guide.
REACTIONS All bearings 21-4-0.
(lb) - Max Uplift All uplift 100 lb or less at joint(s) 27, 28, 29, 30, 31 except 20=-165(LC
6), 19=-153(LC 6)
Max Grav All reactions 250 lb or less at joint(s) 2, 24, 25, 27, 28, 17, 29, 30, 31,
22, 21, 23 except 20=504(LC 16), 19=534(LC 16)
FORCES (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
WEBS 15-20=-432/205, 16-19=-461/207
NOTES
1) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=30ft; Cat. II; Exp B; enclosed; C-C Exterior(2); cantilever left and right
exposed ; end vertical left and right exposed; Lumber DOL=1.33 plate grip DOL=1.33
2) TCLL: ASCE 7-05; Pf=20.0 psf (flat roof snow); Category II; Exp B; Fully Exp.; Ct=1.1, Lu=50-0-0
3) Unbalanced snow loads have been considered for this design.
4) This truss has been designed for greater of min roof live load of 12.0 psf or 2.00 times flat roof load of 20.0 psf on overhangs
non-concurrent with other live loads.
5) This truss has been designed for basic load combinations, which include cases with reductions for multiple concurrent live loads.
6) Provide adequate drainage to prevent water ponding.
7) All plates are 2x4 MT20 unless otherwise indicated.
8) Gable requires continuous bottom chord bearing.
9) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
10) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 27, 28, 29, 30, 31
except (jt=lb) 20=165, 19=153.
11) "Semi-rigid pitchbreaks including heels" Member end fixity model was used in the analysis and design of this truss.
12) Graphical purlin representation does not depict the size or the orientation of the purlin along the top and/or bottom chord.
13) Warning: Additional permanent and stability bracing for truss system (not part of this component design) is always required.
LOAD CASE(S) Standard
Design valid for use only with MiTek connectors. This design is based only upon parameters shown, and is for an individual building component. Applicability of design parameters and proper incorporation of component is responsibility of building designer - not truss designer. Bracing shown is for lateral support of individual web members only. Additional temporary bracing to insure stability during construction is the responsibillity of theerector. Additional permanent bracing of the overall structure is the responsibility of the building designer. For general guidance regardingfabrication, quality control, storage, delivery, erection and bracing, consult 14515 N. Outer Forty, Suite #300
Chesterfield, MO 63017
ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 781 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information
February 12,2015
Job
1500058
Truss
V13
Truss Type
VALLEY
Qty
1
Ply
1
SOUTHILL C STANDARD
Job Reference (optional)
I23659157
7.430 s Jul 25 2013 MiTek Industries, Inc. Wed Feb 11 15:05:30 2015 Page 1 Timberland Lumber Company, Indianapolis, IN 46222
ID:6wSYySsChxEClNJ8ETXMjTzZ3cH-fr?6xHq7m8dafCchIIGUyla5JVVpgQ37P5rWRYzmAbZ
Scale = 1:17.5
1
2
3
2x4
3x4
2x4
4-10-11
4-10-11
2-5-6
2-5-6
4-10-11
2-5-6
2-10-414.00 12
Plate Offsets (X,Y): [2:Edge,0-3-1]
LOADING (psf)
TCLL
(Roof Snow=20.0)
TCDL
BCLL
BCDL
20.0
10.0
0.0
10.0
SPACING
Plates Increase
Lumber Increase
Rep Stress Incr
Code
2-0-0
1.15
1.15
YES
IRC2006/TPI2002
CSI
TC
BC
WB
(Matrix)
0.17
0.35
0.00
DEFL
Vert(LL)
Vert(TL)
Horz(TL)
in
n/a
n/a
0.00
(loc)
-
-
3
l/defl
n/a
n/a
n/a
L/d
999
999
n/a
PLATES
MT20
Weight: 13 lb FT = 0%
GRIP
197/144
LUMBER
TOP CHORD 2x4 SPF Stud/No.3
BOT CHORD 2x4 SPF Stud/No.3
BRACING
TOP CHORD Structural wood sheathing directly applied or 4-10-11 oc purlins.
BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing.
MiTek recommends that Stabilizers and required cross bracing
be installed during truss erection, in accordance with Stabilizer
Installation guide.
REACTIONS (lb/size)1=170/4-10-11 (min. 0-1-8), 3=170/4-10-11 (min. 0-1-8)
Max Uplift1=-32(LC 6), 3=-32(LC 6)
FORCES (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
NOTES
1) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=30ft; Cat. II; Exp B; enclosed; C-C Exterior(2); cantilever left and right
exposed ; end vertical left and right exposed; Lumber DOL=1.33 plate grip DOL=1.33
2) TCLL: ASCE 7-05; Pf=20.0 psf (flat roof snow); Category II; Exp B; Fully Exp.; Ct=1.1
3) Unbalanced snow loads have been considered for this design.
4) This truss has been designed for basic load combinations, which include cases with reductions for multiple concurrent live loads.
5) Gable requires continuous bottom chord bearing.
6) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 1, 3.
8) "Semi-rigid pitchbreaks including heels" Member end fixity model was used in the analysis and design of this truss.
9) Warning: Additional permanent and stability bracing for truss system (not part of this component design) is always required.
LOAD CASE(S) Standard
Design valid for use only with MiTek connectors. This design is based only upon parameters shown, and is for an individual building component. Applicability of design parameters and proper incorporation of component is responsibility of building designer - not truss designer. Bracing shown is for lateral support of individual web members only. Additional temporary bracing to insure stability during construction is the responsibillity of theerector. Additional permanent bracing of the overall structure is the responsibility of the building designer. For general guidance regardingfabrication, quality control, storage, delivery, erection and bracing, consult 14515 N. Outer Forty, Suite #300
Chesterfield, MO 63017
ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 781 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information
February 12,2015
Job
1500058
Truss
V14
Truss Type
VALLEY
Qty
1
Ply
1
SOUTHILL C STANDARD
Job Reference (optional)
I23659158
7.430 s Jul 25 2013 MiTek Industries, Inc. Wed Feb 11 15:05:30 2015 Page 1 Timberland Lumber Company, Indianapolis, IN 46222
ID:6wSYySsChxEClNJ8ETXMjTzZ3cH-fr?6xHq7m8dafCchIIGUyla79VZmgQ37P5rWRYzmAbZ
Scale = 1:11.6
1
2
3
2x4
3x4
2x4
2-10-11
2-10-11
1-5-6
1-5-6
2-10-11
1-5-6
1-8-414.00 12
Plate Offsets (X,Y): [2:Edge,0-3-1]
LOADING (psf)
TCLL
(Roof Snow=20.0)
TCDL
BCLL
BCDL
20.0
10.0
0.0
10.0
SPACING
Plates Increase
Lumber Increase
Rep Stress Incr
Code
2-0-0
1.15
1.15
YES
IRC2006/TPI2002
CSI
TC
BC
WB
(Matrix)
0.05
0.10
0.00
DEFL
Vert(LL)
Vert(TL)
Horz(TL)
in
n/a
n/a
0.00
(loc)
-
-
3
l/defl
n/a
n/a
n/a
L/d
999
999
n/a
PLATES
MT20
Weight: 7 lb FT = 0%
GRIP
197/144
LUMBER
TOP CHORD 2x4 SPF Stud/No.3
BOT CHORD 2x4 SPF Stud/No.3
BRACING
TOP CHORD Structural wood sheathing directly applied or 2-10-11 oc purlins.
BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing.
MiTek recommends that Stabilizers and required cross bracing
be installed during truss erection, in accordance with Stabilizer
Installation guide.
REACTIONS (lb/size)1=90/2-10-11 (min. 0-1-8), 3=90/2-10-11 (min. 0-1-8)
Max Uplift1=-17(LC 4), 3=-17(LC 4)
FORCES (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
NOTES
1) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=30ft; Cat. II; Exp B; enclosed; C-C Exterior(2); cantilever left and right
exposed ; end vertical left and right exposed; Lumber DOL=1.33 plate grip DOL=1.33
2) TCLL: ASCE 7-05; Pf=20.0 psf (flat roof snow); Category II; Exp B; Fully Exp.; Ct=1.1
3) This truss has been designed for basic load combinations, which include cases with reductions for multiple concurrent live loads.
4) Gable requires continuous bottom chord bearing.
5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 1, 3.
7) "Semi-rigid pitchbreaks including heels" Member end fixity model was used in the analysis and design of this truss.
8) Warning: Additional permanent and stability bracing for truss system (not part of this component design) is always required.
LOAD CASE(S) Standard
Design valid for use only with MiTek connectors. This design is based only upon parameters shown, and is for an individual building component. Applicability of design parameters and proper incorporation of component is responsibility of building designer - not truss designer. Bracing shown is for lateral support of individual web members only. Additional temporary bracing to insure stability during construction is the responsibillity of theerector. Additional permanent bracing of the overall structure is the responsibility of the building designer. For general guidance regardingfabrication, quality control, storage, delivery, erection and bracing, consult 14515 N. Outer Forty, Suite #300
Chesterfield, MO 63017
ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 781 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information
February 12,2015
edge of truss.from outside"16/1-0PRODUCT CODE APPROVALSJOINTS ARE GENERALLY NUMBERED/LETTERED CLOCKWISEAROUND THE TRUSS STARTING AT THE JOINT FARTHEST TOTHE LEFT.CHORDS AND WEBS ARE IDENTIFIED BY END JOINTNUMBERS/LETTERS.W
4
-
6
W3-6W3-
7
W2-7W1-7C1-8
C5-6C6-7C7-8C4-5 C3-4C2-3C1-2TOP CHORD
TOP CHORD
87654321BOTTOM CHORDSTOP CHORDSBEARINGLATERAL BRACING LOCATIONIndicates location where bearings(supports) occur. Icons vary butreaction section indicates jointnumber where bearings occur.Min size shown is for crushing only.Indicated by symbol shown and/orby text in the bracing section of theoutput. Use T or I bracingif indicated.The first dimension is the plate width measured perpendicular to slots. Second dimension isthe length parallel to slots.4 x 4PLATE SIZEThis symbol indicates the required direction of slots inconnector plates."16/1For 4 x 2 orientation, locateplates 0- Center plate on joint unless x, yoffsets are indicated.Dimensions are in ft-in-sixteenths.Apply plates to both sides of trussand fully embed teeth.1"4/3PLATE LOCATION AND ORIENTATIONSymbolsNumbering System1. Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI.2. Truss bracing must be designed by an engineer. For wide truss spacing, individual lateral braces themselves may require bracing, or alternative Tor I bracing should be considered.3. Never exceed the design loading shown and never stack materials on inadequately braced trusses.4. Provide copies of this truss design to the building designer, erection supervisor, property owner and all other interested parties.5. Cut members to bear tightly against each other.6. Place plates on each face of truss at each joint and embed fully. Knots and wane at joint locations are regulated by ANSI/TPI 1.7. Design assumes trusses will be suitably protected from the environment in accord with ANSI/TPI 1.8. Unless otherwise noted, moisture content of lumber shall not exceed 19% at time of fabrication.9. Unless expressly noted, this design is not applicable for use with fire retardant, preservative treated, or green lumber.10. Camber is a non-structural consideration and is the responsibility of truss fabricator. General practice is to camber for dead load deflection.11. Plate type, size, orientation and location dimensions indicated are minimum plating requirements.12. Lumber used shall be of the species and size, and in all respects, equal to or better than that specified.13. Top chords must be sheathed or purlins provided at spacing indicated on design.14. Bottom chords require lateral bracing at 10 ft. spacing, or less, if no ceiling is installed, unless otherwise noted.15. Connections not shown are the responsibility of others.16. Do not cut or alter truss member or plate without prior approval of an engineer.17. Install and load vertically unless indicated otherwise.18. Use of green or treated lumber may pose unacceptable environmental, health or performance risks. Consult with project engineer before use.19. Review all portions of this design (front, back, words and pictures) before use. Reviewing pictures alone is not sufficient.20. Design assumes manufacture in accordance with ANSI/TPI 1 Quality Criteria.Failure to Follow Could Cause PropertyDamage or Personal InjuryGeneral Safety Notes*Plate location details available in MiTek 20/20software or upon request.Industry Standards:6-4-8dimensions shown in ft-in-sixteenths (Drawings not to scale)' 2012 MiTekfi All Rights ReservedMiTek Engineering Reference Sheet: MII-7473 rev. 01/29/2013WEBSedge of truss.from outside"16/1-0ICC-ES Reports:ESR-1311, ESR-1352, ESR1988ER-3907, ESR-2362, ESR-1397, ESR-3282JOINTS ARE GENERALLY NUMBERED/LETTERED CLOCKWISEAROUND THE TRUSS STARTING AT THE JOINT FARTHEST TOTHE LEFT.CHORDS AND WEBS ARE IDENTIFIED BY END JOINTNUMBERS/LETTERS.W
4
-
6
W3-6W3-
7
W2-7W1-7C1-8
C5-6C6-7C7-8C4-5 C3-4C2-3C1-2TOP CHORD
TOP CHORD
87654321BOTTOM CHORDSTOP CHORDSBEARINGIndicates location where bearings(supports) occur. Icons vary butreaction section indicates jointnumber where bearings occur.4 x 4PLATE SIZEThis symbol indicates the required direction of slots inconnector plates."16/1For 4 x 2 orientation, locateplates 0- 1"4/3PLATE LOCATION AND ORIENTATIONSymbolsNumbering SystemGeneral Safety Notes*Plate location details available in MiTek 20/20software or upon request.Industry Standards:ANSI/TPI1: National Design Specification for Metal Plate Connected Wood Truss Construction.DSB-89: Design Standard for Bracing.BCSI: Building Component Safety Information, Guide to Good Practice for Handling, Installing & Bracing of Metal Plate Connected Wood Trusses.6-4-8dimensions shown in ft-in-sixteenthsWEBS SYP represents values as published by AWC in the 2005/2012 NDS SP represents ALSC approved/new values with effective date of June 1, 2013 Southern Pine lumber designations are as follows: