Loading...
HomeMy WebLinkAboutA000.31212 TOP OF FOUNDATION TOP OF FLOOR TOP OF PLATE WINDOW HEAD HGT. WINDOW HEAD HGT. TOP OF PLATE TOP OF FLOOR \A1;10'-1{\H0.750000x;\S1#8;}"\A1;8'-2{\H0.750000x;\S7#8;}" \A1;9'-1{\H0.750000x;\S1#8;}"\A1;8'-2{\H0.750000x;\S7#8;}" 1212 1212 1212 1212 1212 1212 1212 1212 12126:12 FIPON LV14x30 W/4" TRIM, PER SPEC SMOOTH PANEL, PER SPEC4" CORNER BOARD, PER SPEC 6" FASCIA BOARD, PER SPEC10" FRIEZE BOARD, PER SPEC STONE VENEER, PER SPEC 6" TRIM, PER SPECSTONE CAP, PER SPEC ROOF SHINGLES, PER SPEC BRICK VENEER, PER SPEC \pxql;6" FASCIA BOARD, PER SPEC6" TRIM, PER SPEC BRICK HEADER, PER SPEC18" SHUTTER, PER SPEC 6:12 SMOOTH PANEL, PER SPECSTONE SILL, PER SPEC 6" TRIM, PER SPECTRIM HEADER, PER SPECLV8X30, PER SPEC \A1;8'-3{\H0.750000x;\S1#2;}" \A1;2'-2{\H0.750000x;\S7#8;}" SHUTTER DOG, PER SPEC \A1;12'-8{\H0.750000x;\S5#8;}" BRICK HEADER, PER SPECBRICK SILL, PER SPEC 6" TRIM, PER SPEC \A1;6'-7{\H0.750000x;\S1#8;}"\A1;PLATE HEIGHT SCALE:FRONT ELEVATION1/4" = 1'-0"- 1212 1212 1212129 TOP OF FLOOR \A1;10'-1{\H0.750000x;\S1#8;}" \A1;9'-1{\H0.750000x;\S1#8;}"\A1;8'-2{\H0.750000x;\S7#8;}"\A1;HDR. HGT. TYP.TOP OF PLATE \A1;8'-2{\H0.750000x;\S7#8;}"\A1;HDR. HGT. TYP. TOP OF PLATE TOP OF FOUNDATION TOP OF FLOOR 124 SCALE:REAR ELEVATION1/8" = 1'-0"- 1X10 TRIM, \PPER SPEC1212 129129 129 \A1;8'-3{\H0.750000x;\S1#2;}" \A1;9{\H0.750000x;\S3#4;}" 129 SCALE:LEFT ELEVATION1/8" = 1'-0"- 124 129 129 129 124124 SCALE:RIGHT ELEVATION1/8" = 1'-0"- SADDLE SCALE:ROOF PLAN1/8" = 1'-0"- 4:12 \A1;1'-0"\PTYP. 12:1212:12 12:12 4:12 4:12 12:1212:12 \A1;4'-0" ROOF AREASQ. FT."C"309 9:12 9:129:12 9:12 9:12 12:12 \A1;1'-0"\PTYP. \A1;1'-0"\PTYP. \A1;1'-0"\PTYP. 12:12 \A1;14'-0"\A1;12'-0" 12:1212:12 9:12 12:12 12:12 9:12 9:12 9:12 4:124:124:12 9:1212:12 9:12 12:12 ROOF AREASQ. FT."B"262 ROOF AREASQ. FT."A"2491 ELEVATION TD3G ATTIC VENT SCHEDULE VENTILATION REQUIRED AND SUPPLIED IS BASED ON POT VENT VALUES AND RIDGE VENT VALUES SHOWN IN TABLE ABOVE ** CONTRACTORS INSTALLING VENTILATION ARE RESPONSIBLE FOR VERIFYING THAT VENTS USED WILL SUPPY VENTILATION TO MEET CODE REQUIREMENTS * SCHEDULE HAS BEEN CALCULATED ASSUMING EAVE VENTILATION AT 50-60% OF TOTAL AND RIDGE AT 40-50% OF TOTAL REQUIRED VENTILATION ROOF AREA "A"SQ FTG 2455 AT / NEAR RIDGE AT / NEAR EAVE VENT TYPE SQ. FT. REQUIRED RANGE SQ. FT. SUPPLIED PERCENT OF TOTAL SUPPLIED POT LARGE (SQ. IN. EACH) POT SMALL (SQ. IN. EACH) RIDGE VENT (SQ. IN. PER LF) EAVE VENT (SQ. IN. EACH) CONT. VENT (SQ. IN. PER LF) 61.00 40.00 18.00 28.00 10.00 HIGH - POT VENTS ONLY 3.27 4.09 4.24 50.00 10 0 AT EAVE 4.91 4.09 4.24 50.00 0 61.00 TOTAL (MIN)8.18 8.18 8.47 100.00 3 HIGH - RIDGE VENT 3.27 4.09 4.10 49.58 2 0 26.00 AT EAVE 4.91 4.09 4.17 50.42 0 60.00 TOTAL (MIN)8.18 8.18 8.26 100.00 ADDITIONAL POT VENTS MAY BE REQUIRED IF THERE IS INSUFFICIENT RIDGE AVAILABLE ELEVATION TD3G ROOF AREA "B"SQ FTG 262 AT / NEAR RIDGE AT / NEAR EAVE VENT TYPE SQ. FT. REQUIRED RANGE SQ. FT. SUPPLIED PERCENT OF TOTAL SUPPLIED POT LARGE (SQ. IN. EACH) POT SMALL (SQ. IN. EACH) RIDGE VENT (SQ. IN. PER LF) EAVE VENT (SQ. IN. EACH) CONT. VENT (SQ. IN. PER LF) 61.00 40.00 18.00 28.00 10.00 HIGH - POT VENTS ONLY 0.35 0.44 0.00 0.00 0 0 AT EAVE 0.52 0.44 0.90 100.00 0 13.00 TOTAL (MIN)0.87 0.87 0.90 100.00 3 HIGH - RIDGE VENT 0.35 0.44 0.00 0.00 0 0 0.00 AT EAVE 0.52 0.44 0.90 100.00 0 13.00 TOTAL (MIN)0.87 0.87 0.90 100.00 ADDITIONAL POT VENTS MAY BE REQUIRED IF THERE IS INSUFFICIENT RIDGE AVAILABLE ELEVATION TD3G ROOF AREA "C"SQ FTG 309 AT / NEAR RIDGE AT / NEAR EAVE VENT TYPE SQ. FT. REQUIRED RANGE SQ. FT. SUPPLIED PERCENT OF TOTAL SUPPLIED POT LARGE (SQ. IN. EACH) POT SMALL (SQ. IN. EACH) RIDGE VENT (SQ. IN. PER LF) EAVE VENT (SQ. IN. EACH) CONT. VENT (SQ. IN. PER LF) 61.00 40.00 18.00 28.00 10.00 HIGH - POT VENTS ONLY 0.41 0.52 0.85 48.41 2 0 AT EAVE 0.62 0.52 0.90 51.59 0 13.00 TOTAL (MIN)1.03 1.03 1.75 100.00 3 HIGH - RIDGE VENT 0.41 0.52 0.50 35.64 0 0 4.00 AT EAVE 0.62 0.52 0.90 64.36 0 13.00 TOTAL (MIN)1.03 1.03 1.40 100.00 ADDITIONAL POT VENTS MAY BE REQUIRED IF THERE IS INSUFFICIENT RIDGE AVAILABLE ........................... PLAN NAME SHEET PRODUCTION MANAGER DATE / DESCRIPTION NPC PLAN NUMBERLAWSON PLAN ID GARAGE HANDING REV # NOTE: SCALES NOTED ON DRAWINGS RELATE TO FULL SIZE PLOTS ON 22x34 SHEETS - 11x17 SHEETS REPRESENT 1/2 SCALE PLOTS INITIAL RELEASE DATE:CURRENT RELEASE DATE: (c) Copyright Pulte Home Corporation - 2018 Joel Hampshire 03/01/2016 Right Skyview 2056.300.00.CPM LOT 193 02/22/20181900 E. Golf Road, - Suite 300Schaumburg, Illinois 60173Midwest Zone OfficePLOTTED: April 11, 2018 / Rudolph Sanchez / 2056-SKYVIEW-IN-WCLY-EL-TD3G.DWG A3-TD3G 3SB.1Tudor3 Car GarageFront, Side and Rear Elevations, Roof Plan and Ventilation Schedule05/17/18 William Hohlt