HomeMy WebLinkAbout04120095 Building Plans (2)SAN MH No 10
oh o
o, m rn
k
10 K
0
N k
/ Oh'
k
aW
0
875
0
Z Z r o�
os
V 20' SAN SEWER EASEMENT o
Jvo
DW
^�
z~ rn�
F-
,
to o ti k k
05
W 0- , ' "')
k cc
882.56
INV -$81,81(N W)
INV-BN3 71(SE)
882.54
+ SEE PHASE 2
SANITARY RECORD DRAWINGS
FOR CONTINUATION
0
, a
ti
130
k ..
o� m
,1� • k o ` k k
x., � 1 SAN M
� S-6
Al
k �V
EXISTING UTILITIES co .41,P`
►- (TELEPHONE, CTV, WATER
GAS & ELECTRIC)
FOR CON TI N U ATI ON
SEE SHEET S-5
SAN MH No 8A
INV- NW J
I 881.97
it 227.01' ✓ I
Z2r of 12" PVC (SDR35) O 0.25%
I
I
II..La
z_
IJ
o
o IU
z �
N N 1�
89&56
- 8' STUB (E)
INV -88444&
C211
881.85
- INV-882-93(SE)
INV-$8ir-18(N W) -
881.60
100.3' ✓
3.Aa' of 12" PVC
(SDR35) O 0.251
GENERAL NOTES:
11"Y L �AY� 1. ALL CUTS ARE TAKEN FROM THE EXISTING GRADE
FOR CONTINUATION " pp�t' / TO THE PIPE INVERT.
SEE SHEET S-5 � ' / � M � 2 ' OLM FROM THENEAREST A DOWNSTREAM L AND PROFILE STATIONS ARE
MH ( )
3. WYES AND LATERALS TO BE 6" PIPE UNLESS
OTHERWISE SPECIFIED.
4. ALL WYE CONNECTIONS SHALL HAVE A MINIMUM
EXISTING LAKE WATERLINE / / OF FIVE FOOT LATERAL EXTENSION CONNECTED TO
THE WYE. THE END OF THE LATERAL SHALL BE
1 SAN MH No % ' EXISTING SHELL OIL PLUGGED OR CAPPED.
S-6 CO. PIPELINES CV llwSW3624544 5. LATERALS RUNNING TO THE OPPOSITE SIDE OF
EXISTING / / / 1"'SOO 28w54OO WAYS EXTENDET SHALL AST THE RIGHT OF
LINE (PROPERTYL NE) N
STORM SEWER 0 D K11 rl 02 FOR CALLS OUTSIDE OF INDIANA Z
0
/ 6 YOTIY�NEILITY
� V STREET Ft
I` CONSTRUCTION BEGINS.
o
• k CAUTION: MULTIPLE EXISTING UTILITIES Q 7. TEMPORARY TRAFFIC CONTROL DURING
�.
o (ELECTRIC, TELEPHONE, GAS, & CTV) J /„ CONSTRUCTION TO CONFORM TO APPLICABLE
I RECEIVING PIT \ v! LOCAL AND STATE STANDARDS. 4
{ 8. ALL CONSTRUCTION ACTIVITY ON THIS SITE TO BE
44j PERFORMED IN COMPLIANCE WITH APPLICABLE O.S.H.A.
o 20' SAN SEWER EASEMENT V`
OSTANDARDS FOR WORKER SAFETY.
� o T
`bfRE�
273' �f 12" PVC ,' 1 1 N V 9. CONTRACTOR SHALL MINIMIZE DAMAGE TO
(SDR35) ®;�._ ✓N MH m� EXISTING TREES. TREES WITHIN OR IMMEDIATELY
�' WYE +>r LAT S-6 a ^,� ADJACENT TO EASEMENT SHALL BE RELOCATED
o OR PROTECTED AGAINST DAMAGE AT THE
SAN MH No 8 '� 0.187: 1 2+00 / °j� `° m ^ O DIRECTION OF THE OWNER OR THE ENGINEER. a
o� ry �
C/) 10. CONTRACTOR SHALL VERIFY DEPTH OF 12" } I
EXISTING 16 o
WATER MAIN Q ✓ N k x o) PIPELINE ON NORTH SIDE OF ROAD PRIOR TO BORING. m
z z EXISTING UTILITY k 'WYE O LAT "� o, vg"o,� ^ ' ®m 11. A MAXIMUM OF 20 FT OF PIPELINE MAY BE EXPOSED. Z
1- JO PEDESTALS 1+90 V o, CID � rno`'' o,�� 12. CONTRACTOR IS RESPONSIBLE FOR ALL COSTS
' `oICI' CHARGED BY PIPELINE CO. FOR ANY DAMAGE
TO PIPELINE OR COATING
0 13. SHELL OIL CO. SH ALL BE •CCW TAC%n NO TATER
„ » ZB�,°jo� o� ' �o� TWO(2) DAYS PRIOR TO BORING AROUND PIPELINE. ,C
CERTIFICATION FOR ECORD DRAWING Q ` k 194? k k o i
Al rn
Al m
CERTIFIED BY: �.;��F� 1AN MH N 6
SCHNEIDER ENGINEERING CORPORATIONi S-6
3020 NORTH POST ROAD i 870015-.
INDIANAPOLIS. INDIANA 46226-6518 STATE OF
P.O. eox 26066 (317) 89e -e282
Of, - �lA� �
NOTE. SURV
SANITARY SEWER
Record drawing certification only for top of costing, Invert
elevations and lengths of pipe. ,Slope percentage represents DATE: 5.� X95
a calculated figure and is for general information only.
House lateral location, length and/ordepth information RECOR R WING
furnished by contractor and is excluded from this certification.
SANITARY SEW
R PLAN SCALE: 1"=50' o
W
U
897.90
TC-•
---------------------------------------------
e,
8' PVC (W)
INV-B>i2.
891.85
8' DROP PIPE883,17
INV -$83.1'S w
INV -0114 -."(SE)
EXISTING STORM SEWER
24" RCP, INV -892.8±
881.
8" PVC (E _\
INV -
INV -(NW)
881.46 880.96
273' of 12" PVC (SDR35) 01145% A. 0.18X
SANITARY
TC- W r?5
M M M
8" SHELL OIL CO.
PIPELINE
12' SHELL OIL CO.
PIPELINE
EXISTING 16"
WATER MAIN
ao N BORE UNDER STREET
(30' CASING, 0.406" WALL THICKNESS)
INV-8$0�'O(S)
880.92
W
' o
0
M
�SE'vER
417.4' ✓ I ✓
of 12" PVC (SDR35) O 0.25%
0
0
N
PROFILE
t,
TC -899.25
IMV-$30-T3(SE)
879.58 879.80
88' of 12" PVC
(SDR35) O QaW
0.27%
0
CID
u�
z
0
0
rn
00
r`
0
0
zo
z
z
+
V
N
N
N
SANITARY
TC- W r?5
M M M
8" SHELL OIL CO.
PIPELINE
12' SHELL OIL CO.
PIPELINE
EXISTING 16"
WATER MAIN
ao N BORE UNDER STREET
(30' CASING, 0.406" WALL THICKNESS)
INV-8$0�'O(S)
880.92
W
' o
0
M
�SE'vER
417.4' ✓ I ✓
of 12" PVC (SDR35) O 0.25%
0
0
N
PROFILE
t,
TC -899.25
IMV-$30-T3(SE)
879.58 879.80
88' of 12" PVC
(SDR35) O QaW
0.27%
I
905
OND 8
OD Z � N
Q °0
900 n00
Q. °� n
TC-89s�69"
tY
0
898.47 TC -89&W 896.79 0 0 N
------------�---- a i
Cr
895 W
z 6zi
?
zVf
z o�
a �`
890 a W) Cn
z V O
V c
N CP L-
Cm
0
. 885---- o
879.92
7 '
_e_ 6. STUB (W)
..INV-�6 _
INV $7x49
Qz
N
CO
. to
INV -$T� 3(S) INV -87Q -"S) •� Z�'
r a
I N INV-$?a-ro(N) 879.±7 875 q� ~
z
W
V
V/�f 12' PVC ' <Uj z
(SDR35) EL V) -j Q
0.38% Z j -a
CL
to o
W
W W 'S
z z �
W D �
z I 060
J m fn
ufm Q
= I _l8
z -1 F-
p= W Q
0
Q M a m FV)
SHEET
HORZ.: 1"=50' SOf
SCALE: VERT.: 1 =5 5
MW
CID
u�
z
z
I
905
OND 8
OD Z � N
Q °0
900 n00
Q. °� n
TC-89s�69"
tY
0
898.47 TC -89&W 896.79 0 0 N
------------�---- a i
Cr
895 W
z 6zi
?
zVf
z o�
a �`
890 a W) Cn
z V O
V c
N CP L-
Cm
0
. 885---- o
879.92
7 '
_e_ 6. STUB (W)
..INV-�6 _
INV $7x49
Qz
N
CO
. to
INV -$T� 3(S) INV -87Q -"S) •� Z�'
r a
I N INV-$?a-ro(N) 879.±7 875 q� ~
z
W
V
V/�f 12' PVC ' <Uj z
(SDR35) EL V) -j Q
0.38% Z j -a
CL
to o
W
W W 'S
z z �
W D �
z I 060
J m fn
ufm Q
= I _l8
z -1 F-
p= W Q
0
Q M a m FV)
SHEET
HORZ.: 1"=50' SOf
SCALE: VERT.: 1 =5 5
MW