HomeMy WebLinkAbout04120083 Building PlansDESIGNER: LYNN HYNES INC. 9 6945 WARWICK RD. INDIANAPOLIS, IN 46220 OFFICE: (317) 251-4238 CELL: (317) 496-0464 ARCHITECT: 114 280 E. 96TH STREET, SUITE 200 INDIANAPOLIS, INDIANA 46240 (317) 848.7800 (317) 574.1869 FAX CONTRACTOR: ��i Duke REALTY CORPORATION 600 E. 96th STREET SUITE 100 INDIANAPOLIS, IN 46240 PHONE: (317)808-6000 INDEX UOR'4F DRAWINGS • PERFORM FINAL CLEANING, EMPLOYING EXPERIENCED PROFESSIONAL COVER MILLWORK SHALL BE FABRICATED FROM FIELD MEASUREMENTS WITH • D201 DEMOLITION PLAN • PROTECT HARDWARE, PLATES AND SIMILAR TRIM. AFTER PAINT IS DRY, A201 CONSTRUCTION PLAN • DO NOT DELIVER CASEWORK AND FINISH CARPENTRY UNTIL PAINTING, A202 REFLECTED CEILING PLAN • A601 ELEVATIONS AND DETAILS • PROVIDE OPERATING AND MAINTENANCE MANUALS WITH INFORMATION A801 FINISH PLAN • E201 ELECTRICAL PLAN APPROVED AS SUBMITTED APPROVED AS NOTED ❑ REJECTED SIGNATURE DATE COMPANY THIRD FLOOR KEYPLAN SCALE: NTS FIVE PARKWOOD SPECIFICATIONS AND GENERAL NOTES 0 CONTRACT CONDITIONS 0.1 THE GENERAL CONDITIONS SHALL BE AIA DOCUMENT A201 - 1987 EDITION 0.2 0.3 0.4 0.5 0.6 0.7 1 1.1 1.2 1.3 1.4 Al 1.6 ENTITLED "GENERAL CONDITIONS OF THE CONTRACT FOR CONSTRUCTION". THIS DOCUMENT MAY BE OBSERVED IN THE OFFICE OF THE ARCHITECT. INCLUDED IN THE GENERAL CONDITIONS ARE RESPONSIBILITIES OF THE CONTRACTOR WHICH MAY BE PARAPHRASED AS FOLLOWS: 3.2 STUDY THE CONTRACT DOCUMENTS, VERIFY DIMENSIONS AND FIELD CONDITIONS AND REPORT DISCREPANCIES BEFORE PROCEEDING WITH CONSTRUCTION. 3.3 SUPERVISE, DIRECT AND COORDINATE THE WORK, WITH SOLE RESPONSIBILITY AND CONTROL OVER CONSTRUCTION MEANS, METHODS, TECHNIQUES, SEQUENCES AND PROCEDURES. 3.7 OBTAIN AND PAY FOR THE BUILDING PERMIT AND NECESSARY GOVERNMENTAL FEES, LICENSES AND INSPECTIONS. 3.14 CUT AND PATCH EXISTING SURFACES TO MATCH EXISTING ADJACENT SURFACES, USING EQUAL QUALITY MATERIALS AND WORKMANSHIP. 10.1 INITIATE, MAINTAIN AND SUPERVISE PROJECT SAFETY PRECAUTIONS AND PROGRAMS, WHICH ARE SOLELY THE CONTRACTOR'S RESPONSIBILITY. WORK MUST COMPLY WITH APPLICABLE LAWS, CODES, ORDINANCES, RULES AND REGULATIONS. ALL MATERIALS AND EQUIPMENT SHALL BE OF INDUSTRY STANDARD QUALITY, WHETHER SPECIFIED OR NOT, AND WITHIN THE LIMITATIONS OF THE CONTRACT DOCUMENTS, TO CAUSE THE INSTALLATION TO FUNCTION IN ACCORDANCE WITH THE INTENTION AND OBJECTIVE OF THE FINISHED PROJECT. WHEN NOT INDICATED IN THE CONTRACT DOCUMENTS, PROVIDE THE SIZING OF INTERCONNECTING FACILITIES, SUCH AS PIPING, DUCTS AND WIRING, BETWEEN PIECES OF EQUIPMENT IN ORDER TO UTILIZE THE SPECIFIED CAPACITIES OF THE EQUIPMENT. WHEN NOT INDICATED IN THE CONTRACT DOCUMENTS, THE STANDARD`, ESTABLISHED BY THE RECOGNIZED TRADE ASSOCIATION HAVING JURISDICTION FOR THE PRODUCT INCLUDED IN THE PROJECT SHALL GOVERN THE WORK. NOT ALL ITEMS INDICATED ON THE DRAWINGS ARE INCLUDED IN THESE SPECIFICATIONS. IN THE CASE OF AN INCONSISTENCY BETWEEN DRAWINGS AND SPECIFICATIONS OR WITHIN EITHER ELEMENT NOT CLARIFIED BY ADDENDUM, THE BETTER QUALITY OR GREATER QUANTITY OF WORK SHALL BE PROVIDED IN ACCORDANCE WITH THE ARCHITECT'S INTERPRETATION. INSTALL EQUIPMENT AND MATERIALS IN ACCORDANCE WITH MANUFACTURER'S RECOMMENDATIONS. GENERAL REQUIREMENTS WORK SHALL BE PERFORMED DURING REGULAR BUSINESS HOURS WHENEVER POSSIBLE. WORK INVOLVING OVERTIME, NON -REGULAR BUSINESS HOURS SHALL BE COORDINATED WITH BUILDING MANAGEMENT. THE CONTRACTOR SHALL COORDINATE AND SCHEDULE WORK BY OTHERS INCLUDING BUT NOT LIMITED TO TELEPHONE/DATA, SECURITY, FURNITURE AND 'FURNISHED AND/OR INSTALLED' ITEMS. CONTRACTOR SHALL COORDINATE EXACT LOCATIONS AND SHALL DO THE CUTTING, FITTING, AND PATCHING THAT MAY BE REQUIRED TO MAKE THE PARTS OF THE WORK WHICH WILL RECEIVE THE WORK OF OTHERS AS SHOWN OR REASONABLY IMPLIED BY THE DRAWINGS AND SPECIFICATIONS. CUTTING OF EXISTING SURFACES SHALL BE PATCHED TO MATCH EXISTING ADJACENT SURFACES, INCLUDING WITH REGARD TO MATERIALS AND WORKMANSHIP. SUBMIT SHOP DRAWINGS ( OR SUBMITTALS ) TO THE ARCHITECT FOR THE FOLLOWING ITEMS: .1 METAL FABRICATIONS. .2 ARCHITECTURAL WOODWORK, INCLUDING TRIM AND CABINETS. .3 DOORS, FRAMES AND HARDWARE. .4 SUSPENDED ACOUSTICAL CEILING SYSTEMS ( 6' X 6" ACOUSTICAL PANEL ). .5 VCT FLOORING AND BASE ( COLOR SAMPLES ). .6 CARPET ( DYE LOT CUTTING AND SEAMING DIAGRAMS ). .7 PAINT ( 6' X 6" ON ACTUAL SURFACE ). .8 WALLCOVERINGS ( 9" X 9' DYE LOT CUTTING ). .9 SIGNAGE ( SAMPLE SIGN ). .10 LIGHT FIXTURES ( CATALOG CUTS ). TEMPORARY UTILITIES, INCLUDING WATER, SANITARY FACILITIES, TEMPORARY ENCLOSURES, FIRE PROTECTION, HEAT AND POWER WILL BE PROVIDED BY THE OWNER, SUBJECT TO THE OWNER OR THE OWNER'S AGENT'S DIRECTION. COMPLY WITH SPECIFIC BUILDING CONSTRUCTION RULES PUBLISHED BY THE OWNER OR THE OWNER'S AGENT. THE CONTRACTOR SHALL PROTECT THE BUILDING PREMISES AND OCCUPANTS ON THE PROJECT SITE FROM DAMAGE. THE CONTRACTOR SHALL PROVIDE AND MAINTAIN NECESSARY COVERINGS, BOARDS, TEMPORARY PARTITIONS, AND DOORS AS REQUIRED TO PROTECT EXISTING WORK, MATERIALS, AND FINISHES TO REMAIN AT THE JOB SITE, THE CONTRACTOR SHALL BE HELD RESPONSIBLE FOR DAMAGES ATTRIBUTABLE TO HIS OPERATION, REPAIRS, OR REPLACEMENT WITHOUT ADDITIONAL CHARGE TO THE PARTY AFFECTED. THE CONTRACTOR SHALL MAINTAIN FOR THE ENTIRE LENGTH OF HIS CONTRACT EXITS, EXIT LIGHTING, ARE PROTECTIVE DEVICES AND ALARM.; TO CONFORM TO LOCAL BUILDING CODE REQUIREMENTS. SUBSTITUTION FOR NAMED PRODUCTS WILL NOT BE ALLOWED WITHOUT PRIOR APPROVAL OF THE ARCHITECT. IF A SUBSTITUTION IS PROPOSED, SUBMIT THE FOLLOWING INFORMATION: .1 PROVIDE COMPLETE PRODUCT DATA, DRAWINGS AND DESCRIPTIONS OF PRODUCTS, AND FABRICATION AND INSTALLATION PROCEDURES. .2 PROVIDE SAMPLES WHERE APPLICABLE OR REQUESTED. .3 PROVIDE COMPLETE COORDINATION INFORMATION, INCLUDING ALL CHANGES REQUIRED IN OTHER ELEMENTS OF THE WORK TO ACCOMMODATE THE SUBSTITUTION. .4 PROVIDE A STATEMENT INDICATING HOW THE SUBSTITUTION WILL AFFECT THE CONTRACT SUM AND CONTRACT TIME. STORE MATERIALS ON SITE PRIOR TO INSTALLATION, AND ALLOW TIME FOR THEIR ADJUSTMENT TO AVOID SHRINKAGE OR SWELLING. THE CONTRACTOR SHALL INCLUDE IN HIS BID AND SHALL ARRANGE FOR HOISTING, CARTING, STANDARD AND OVERTIME SERVICES BY THE BUILDING MANAGEMENT AND OVERTIME CHARGES AND EXPENSES WHEN REQUIRED DUE TO BUILDING MANAGEMENT REQUIREMENTS. SUITE 300 INDIANAPOLIS, INDIANA 1.11 PERFORM FINAL CLEANING, EMPLOYING EXPERIENCED PROFESSIONAL 6.7 MILLWORK SHALL BE FABRICATED FROM FIELD MEASUREMENTS WITH 9.10 PAINT: USE PRIMER COMPATIBLE WITH SUBSTRATE. REMOVE OR CLEANERS. CLEAN EACH SURFACE OR UNIT OF WORK TO THE CONDITION PROVISIONS FOR SCRIBING AS REQUIRED TO MEET BUILT-IN CONDITIONS. PROTECT HARDWARE, PLATES AND SIMILAR TRIM. AFTER PAINT IS DRY, EXPECTED FROM A COMMERCIAL BUILDING CLEANING AND MAINTENANCE 6.8 DO NOT DELIVER CASEWORK AND FINISH CARPENTRY UNTIL PAINTING, REINSTALL SUCH ITEMS. PROGRAM IN ACCORDANCE WITH THE MANUFACTURER'S INSTRUCTIONS. WET WORK AND SIMILAR OPERATIONS WHICH COULD DAMAGE FINISHED 1.12 PROVIDE OPERATING AND MAINTENANCE MANUALS WITH INFORMATION WORK HAS BEEN COMPLETED AND HVAC SYSTEMS HAVE BEEN PROPERLY .1 INTERIOR PAINT SCHEDULE: PROVIDE THE FOLLOWING PAINT NECESSARY FOR THE SAFE AND EFFICIENT OPERATION AND OPERATING FOR TEN DAYS. SYSTEMS BASED ON DEVOE TO ESTABLISH QUALITY STANDARD MAINTENANCE OF EQUIPMENT AND OPERATING SYSTEMS CALLED FOR IN 6.9 INSTALL CASEWORK AND FINISH CARPENTRY PLUMB, LEVEL, TRUE AND FOR THE VARIOUS SUBSTRATES, AS INDICATED. THE CONTRACT DOCUMENTS, AND INFORMATION RELATIVE TO THE STRAIGHT WITH NO DISTORTIONS. INSPECTION, CARE AND MAINTENANCE OR REPAIR OF ARCHITECTURAL 6.10 JOINTS BETWEEN MILLWORK DRAWERS, DOORS, ETC., TO BE OF UNIFORM 1. FERROUS METAL PRODUCTS AND FINISHES WHICH ARE OTHER THAN BUILDING STANDARD. WIDTH NOT TO EXCEED 1/8 U.O.N. A ACRYLIC SEMI -GLOSS ENAMEL FINISH: 6.11 GROMMETS ARE TO BE FIELD CUT FOR COORDINATION WITH ELECTRICAL 1. PRIMER: 1 COAT #41702 METALCLAD ACRY'_!C 2 DEMOLITION OUTLETS. LATEX PRIMER. 2. FINISH: 2 COATS #83XX MIRROLAC-WB ACRYLIC 2.1 COORDINATE DEMOLITION WITH CONSTRUCTION PLANS TO DETERMINE SEMI -GLOSS ENAMEL. EXTENT OF WORK. PROVIDE DEMOLITION SUFFICIENT FOR SUITABLE 7 JOINT SEALERS 2. NON-FERROUS METAL: BONDING/PATCHING OF EXISTING CONSTRUCTION TO REMAIN WITH NEW A. ACRYLIC SEMI -GLOSS ENAMEL FINISH: WORK. 7.1 ONE -PART MILDEW -RESISTANT SILICONE SEALANT - AT COUNTERS 1. PRIMER: 1 COAT #41702 METALCLAD ACRYLIC 2.2 WHERE WORK INCLUDES REMOVAL OF EXISTING CONSTRUCTION OR AND FIXTURES: LATEX PRIMER. EQUIPMENT, OR REMOVAL AND PATCHING, REMOVAL AND REPLACEMENT, .1 "DOW CORNING 786"; DOW CORNING CORP. 2. FINISH: 2 COATS #83XX MIRROLACE-WB ACRYLIC OR REMOVAL AND RELOCATION, SURFACES LEFT EXPOSED IN RELATION .2 "SCS 1702 SANITARY'; GENERAL ELECTRIC CO. SEMI -GLOSS FINISH TO SUCH WORK SHALL HAVE ANY EXCESS MATERIALS REMOVED, AND .3 '863 #345 WHITE'; PECORA CORP. 3. FERROUS STRUCTURE: SURFACES SHALL BE PREPPED AND FINISHED TO MATCH EXISTING .4 "PROGLAZE WHITE"; TREMCO CORP. A. ACRYLIC DRY FOG FLAT FINISH: ADJACENT SURFACES, INCLUDING WITH REGARD TO MATERIALS AND .5 'OMNIPWS'; SONNEBORN BUILDING PRODUCTS 1. FINISH: 2 COATS #57601 UNI -GRIP -WB WATER WORKMANSHIP. ADJACENT ITEMS SHALL BE REMOVED AND RELOCATED REDUCIBLE ACRYLIC DRY FOG COATING TO ALLOW SUCH WORK. NO CHANGE ORDER WILL BE ISSUED FOR 7.2 ACRYLIC -EMULSION SEALANT - AT INTERIOR UNLIKE ADJOINING 4. NON-FERROUS STRUCTURE: ADDITIONAL WORK RELATED TO SUCH ACTIVITIES. SURFACES: A. ACRYLIC DRY FOG FLAT FINISH: 2.3 WHERE WORK INCLUDES REMOVAL AND RELOCATION, RELATED .1 "CHEM -CALK 600"; BOSTIK CONSTRUCTION PRODUCTS DIV. 1. FINISH: 2 COATS #57601 UNI -GRIP -WB WATER MECHANICAL AND ELECTRICAL CONNECTIONS AND TERMINATIONS SHALL .2 "AC -20"; PECORA CORP. REDUCIBLE ACRYLIC DRY FOG COATING. BE INCLUDED. .3 'SONOLAC'; SONNEBORN BUILDING PRODUCTS 8. WOOD: 2.4 REPAIR DEMOLITION PERFORMED IN EXCESS OF THAT REQUIRED BY THE .4 'TREMCO ACRYLIC LATEX 834'; TREMCO, INC. A. ACRYLIC LATEX SEMI -GLOSS ENAMEL FINISH: DRAWINGS. 1. PRIMER: 1 COAT #51701 WONDER -PRIME LATEX 2.5 ON EXISTING -CONSTRUCTION -TO -REMAIN, THOROUGHLY REMOVE 8 DOORS AND WINDOWS PRIMER -SEALER. ADHESIVE RESULTING FROM THE REMOVAL OF SURFACE APPLIED 2. FINISH: 2 COATS #83XX MIRROLAC-WB ACRYLIC FINISHES, INCLUDING VINYL BASE, CARPET TILES, ETC. CHEMICALS AND 8.1 INTERIOR DOOR FRAMES: PROVIDE BUILDING STANDARD FRAMES UNLESS SEMI -GLOSS ENAMEL METHODS TO REMOVE THE ADHESIVE SHALL BE COMPATIELE WITH NEW NOTED OTHERWISE. COLOR TO BE SELECTED BY DESIGNER. B. STAIN -VARNISH RUBBED FINISH: FINISHES. 8.2 INTERIOR DOORS: PROVIDE BUILDING STANDARD DOORS UNLESS NOTED 1. FILLER: 1 COAT #4800 WONDER WOODSTAIN 2.6 EXISTING ACOUSTICAL CEILING GRID, SUPPORT SYSTEM AND TILES SHALL OTHERWISE. DOORS TO BE BUILDING STANDARD FINISH. PASTE WOOD FILLER (OPEN GRAIN WOODS). REMAIN, EXCEPT IN THOSE AREAS DAMAGED DURING CONSTRUCTION OR 8.3 DOOR HARDWARE: BUILDING STANDARD WITH ADA LEVER HANDLE LATCH 2. STAIN: 1 COAT #96XX WONDER WOODSTAIN NOTED TO BE REPAIRED. AND LOCKSETS. ALKYD STAIN. 2.7 SALVAGE AND TURN OVER TO THE OWNER ALL REMOVED ITEMS. 8.4 GLASS: MEET ASTM C1036 REQUIREMENTS FOR GLASS AND ASTM C1048 3. SEALER: 1 COAT #4900 WONDER WOODSEALER 2.8 REPAIR AND RESTORE DESIGNATED REUSED EXISTING PRODUCTS AS REQUIREMENTS FOR HEAT -STRENGTHENED GLASS. QUICK DRY SEALER. REQUIRED TO MEET IN FINISHED FORM THE TYPE AND QUALITY OF WORK 4. FINISH: 2 COATS 14600 WONDER WOODSTAIN IN SCOPE OF CONTRACT. 9 FINISHES ALKYD SATIN VARNISH. 2.9 PROVIDE AND MAINTAIN CARPET MATS IN FRONT OF ALL BUILDING 10. GYPSUM WALLBOARD: DOORWAYS USED BY CONSTRUCTION WORKERS FOR ACCESS SUCH AS 9.1 GYPSUM BOARD WALL FRAMING: COMPLY WITH ASTM C645. A ACRYLIC LATEX SATIN ENAMEL FINISH: ELEVATOR DOORWAYS, EXIT STAIR DOORWAYS, ETC. CARPET MATS 1. PRIMER: 1 COAT #50801 WONDER TONES LATEX SHALL BE LARGE ENOUGH TO PREVENT THE HAULING/SPREADING OF DIRT .1 INSTALL "ELIMINATOR" TYPE HEAD TRACK AT WALLS TERMINATING PRIMER -SEALER. THROUGH THE BASE BUILDING PREMISES AND ELEVATOR CABS. AT CEILING. USE PREFORMED OUTSIDE CORNERS. 2. FINISH: 2 COATS #35XX WONDER TONE ACRYLIC 2.10 CONTRACTOR SHALL INSPECT, TEST AND DISCONNECT UTILITY SERVICES LATEX SATIN ENAMEL AT MAIN SOURCE OR MAIN BRANCH WITHOUT DISRUPTING UTILITY 9.2 GYPSUM BOARD: PROVIDE 5/8" THICK REGULAR AND TYPE "X' TAPERED 13. PRECAST CONCRETE: SERVICES IN USE, CONTRACTOR SHALL SECURELY CAP AND/OR VALVE- EDGE GYPSUM BOARD WITH GALVANIZED STEEL TRIM ACCESSORIES AND A. LATEX TEXTURE COATING -SAND FINISH (WET AREAS) OFF UTILITY SERVICE BEHIND FINAL FINISHED SURFACES OF INTENDED JOINT COMPOUND COMPLYING WITH ASTM C475. FINISH IN ACCORDANCE 1. PRIMER: 1 COAT #1502 WONDER -SHIELD ACRYLIC CONSTRUCTION OR, ONLY WHEN NOTED, AT FINISHED FACE PRIOR TO WITH ASTM C840 TO THE HIGHEST QUALITY STANDARDS. LATEX HOUSE PAINT PRIMER. DEMOLITION OPERATIONS, UTILITY SERVICE SHALL BE DEFINED AS 2. FINISH: 1 COAT #44101 DEV-VO-TEX LATEX PLUMBING, HVAC, ELECTRICAL, AND FIRE PROTECTION SYSTEMS. .1 DRYWALL FINISHING: COMPLY WITH MANUFACTURER'S PRINTED TEXTURE COATING. CONTRACTOR SHALL INDICATE PERMANENTLY ABANDONED UTILITIES ON A INSTRUCTIONS AND SPECIFICATIONS. EXCEPTION: COMPLY WITH RECORD SEPIA TO SERVE AS PART OF THE "AS -BUILT" SET. MORE STRINGENT REQUIREMENTS OF GYPSUM ASSOCIATION GA - 2.11 . 1 PROVIDE SHORING AND BRACING, OR SUPPORT TO PRTti�;s� 216 RECOMMENDED SPECIFICATION FOR THE APPLICATION AND 9.11 WALLCOVERING: APPLY WALLCOVERING SECURE, SMOOTH, CLE AN AND SETTLEMENT OR COLLAPSE OF STRUCTURE OR ELEMENT TO BL' FINISHING OF GYPSUM BOARD. WITHOUT WRINKLES, GAPS OR OVERLAPS. DEMOLISHED, AND ADJACENT FACILITIES OR WORK TO RE01N. 9.4 CEILINGS: FINISHED CEILING SHALL BE LEVEL, TRUE AND FREE FROM .1 KEEP SEAMS TO A MINIMUM. HORIZONTAL SEAMS ARE NOT 5 METAL FABRICATIONS DAMAGED OR SOILED TILES. ACCEPTABLE. .2 SEAMS MUST BE AT LEAST 2" FROM INSIDE CORNERS AND 6" FROM 5.1 PROVIDE STEEL FRAMING AND SUPPORTS FOR APPLICATIONS INDICATED .1 COORDINATE PLACEMENT OF MECHANICAL AND ELECTRICAL ITEMS OUTSIDE CORNERS. OR WHICH ARE NOT A PART OF STRUCTURAL STEEL FRAMEWORK, AS IN CEILING. WHERE CONFLICTS OCCUR, THE ARCHITECTURAL REQUIRED TO COMPLETE WORK. REFLECTED CEILING PLAN SHALL GOVERN. 10 SPECIALTIES .2 CENTER COLING ELEMENTS IN CEILING TILE, INCLUDING DOWN 6 WOOD AND PLASTIC LIGHTS, SMOKE DETECTORS, SPRINKLER HEADS AND EXIT SIGNS 10.1 ARE EXTINGUISHERS AND CABINETS: BUILDING STANDARD, OR IF NO UNLESS NOTED OTHERWISE. BUILDING STANDARD, PROVIDE JL INDUSTRIES "AMBASSADOR" SERIES, 6.1 CONCEALED ROUGH FRAMING AND BLOCKING: PROVIDE "CONSTRUCTION SEMI RECESSED, DUO -PANEL, FIELD PAINTED. GRADE" LUMBER OF ANY SPECIES WITH MAXIMUM 19% MOISTURE 9.5 INSTALL FLOOR FINISH TRANSITION STRIP AT CENTERLINE OF DOOR OR CONTENT. CASED OPENING UNLESS NOTED OTHERWISE. 6.2 PLYWOOD BACKING PANELS: FOR MOUNTING ELECTRICAL OR TELEPHONE EQUIPMENT, PROVIDE FIRE -RETARDANT TREATED PLYWOOD PANELS, APA .1 INSTALL JOHNSONTTE TRIM STRIPS AT DOOR WHERE CARPET C -D PLUGGED INT WITH EXTERIOR GLUE, NOT LESS THAN 15/32'. MEETS RESILIENT TILE WITH TRIM STRIP COLOR TO MATCH 6.3 FIRE -RETARDANT TREATMENT. PRESSURE IMPREGNATE LUMBER AND CARPET. PLYWOOD WITH FIRE -RETARDANT CHEMICALS TO COMPLY WITH AWPA C20 AND C27, RESPECTIVELY, AND IDENTIFY LUMBER WITH 9.6 RESILIENT FLOORING: CLASSIFICATION MARKING ACCEPTABLE TO AUTHORITIES HAVING JURISDICTION. .1 UNLESS OTHERWISE NOTED, LAY TILE FROM CENTER MARKS 6.4 FINISH CARPENTRY AND MILLWORK: COMPLY WITH 'PREMIUM GRADE" AWI ESTABLISHED WITH PRINCIPAL WALLS, SO THAT TILE AT STANDARDS. OPPOSITES EDGES OF THE ROOM ARE EQUAL WIDTH. ADJUST TO AVOID USE OF CUT WIDTHS LESS THAN 3" AT ROOM PERIMETER. .1 PROVIDE A FULL SCALE MOCK-UP FOR OWNER'S APPROVAL PRIOR .2 BASE: FIT JOINTS TIGHT AND VERTICAL ON CONTINUOUS SOLID TO FABRICATION OF MULTIPLE UNITS. BACKING. INSTALL BASE IN LONGEST PRACTICAL LENGTHS, USING ROLL STOCK. SCRIBE TO VERTICAL OBSTRUCTIONS. 6.5 COUNTERS: HIGH PRESSURE DECORATIVE LAMINATE COMPLYING WITH NEMA LD 3 AND GP -50 (0.050" NOMINAL THICKNESS). 9.7 USE AN APPROVED CEMENTITIOUS FILLER TO PATCH CRACKS, SMALL HOLES AND LEVELING. ENSURE THAT FLOORS ARE LEVEL WITH MAXIMUM .1 EDGE TREATMENT: SAME AS LAMINATE CLADDING ON HORIZONTAL SURFACE VARIATION OF X" IN 10 FEET, NON -CUMULATIVE. SURFACES. .2 PROVIDE 2" DIAMETER PLASTIC GROMMET IN COUNTERTOP ABOVE ELECTRICAL OR DATA OUTLET LOCATIONS. 9.8 CARPET: INSTALL CARPETING WHICH MEETS THE FOLLOWING STANDARDS: 6.6 CABINETS: COMPLY WITH AWI SECTION 400 AND ITS DIVISION 400B FOR PREMIUM GRADE NEMA LD3 LAMINATE CLAD CABINETS. FLAMMABILITY: ASTM 2859 SURFACE BURNING: ASTM E84 .1 EXPOSED SURFACES: HORIZONTAL SURFACES f'HER THAN TOPS: SMOKE DENSITY: ASTM E662 GP -50 (0.050" NOMINAL THICKNESS); VERTICAL SURFACES: GP -28 SOUND ABSORPTION: ASTM C423 (0.028" NOMINAL THICKNESS); EDGES: GP -25 (0.028" NOMINAL FADE RESISTANCE: AATCC 16E THICKNESS). STATIC RESISTANCE: AATCC 134 .2 SEMI -EXPOSED SURFACES: HIGH PRESSURE LAMINATE, GP -28. WARRANTY: 10 YEARS .3 CABINET HARDWARE SCHEDULE: .1 INSTALL BROADLOOM CARPET BY DIRECT GLUE. .1 HINGES: FULLY CONCEALED, SELF-CLOSING '1000 SERIES' BY GRASS OR EQUAL .2 PULLS: WIRE PROJECTING TYPE, DRIWNG 4' ON CENTER, #4483 OR EQUAL AS MANUFACTURED BY STANLEY. .3 CABINET CATCHES: ADJUSTABLE MAGNETIC CATCHES WITH MINIMUM 8 LBS. PULL; # SP 45 OR SP 46 OR EQUAL AS MANUFACTURED BY STANLEY. .4 DRAWER GLIDES: SIDE AND BOTTOM MOUNTED SLIDES WITH POSITIVE STOP AND LOCKOUT ?OSITION, WITH HEAVY-DUTY FULL EXTENSION; #1429 OR EQUAL AS MANUFACTURED BY KNAPE & VOGT. .5 SHELF SUPPORTS AND STANDARDS: ADJUSTABLE SHELF SUPPORTS CONSTRUCTED OF HIGH IMPACT INJECTION w MOLDED NYLON AND WITH HEAVY DUTY TWIN SLOTTED _ SHELVING STANDARDS AS PRODUCED BY KNAPE & VOGT'" OR EQUAL. 12 FURNISHINGS 12.1 CASEWORK: .1 MANUFACTURERS: PROVIDE PRODUCTS BY ONE OF THE FOLLOWING: .1 IMPERIAL CABINET CO., INC. .2 MERILLAT INDUSTRIES, INC. .3 YORKTOWNE CABINETS 15/16 MECHANICAL AND ELECTRICAL 15/16.1 MECHANICAL (INCLUDING PLUMBING, FIRE PROTECTION AND HVAC) AND ELECTRICAL SYSTEMS ARE TO BE DESIGNED AND CONSTRUCTED BY THE RESPECTIVE DESIGN/BUILD CONTRACTORS OR SUBCONTRACTORS ACCORDING TO CRITERIA DEFINED BY THE TENANT AND AESTHETIC CRITERIA (ONLY) DEFINED BY THE ARCHITECT. THE CONTRACTOR SHALL BEAR FULL RESPONSIBILITY FOR ALL DESIGN, PERFORMANCE, INSTALLATION AND INTER -SYSTEM COORDINATION OF MECHANICAL AND ELECTRICAL SYSTEMS. 15/16.2 GENERAL CONTRACTOR IS TO PROVIDE A COMPLETE PACKAGE OF DESIGN/BUILD DRAWINGS FOR ARE PROTECTION, MECHANICAL, AND PLUMBING, SIGNED AND STAMPED FOR STATE FILING PROCESS BY A Cl RTIFlED ENGINEER. 15/16.3 IN CASE OF CONFLICT BETWEEN ARCHITECT'S AND ENGINEER'S DRAWINGS IN LOCATION OF TERMINAL MATERIALS/EQUIPMENT, SUCH AS DIFFUSERS, GRILLES, LIGHTS (IF SHOWN ON REFLECTED CEILING PLAN) AND SURFACE MOUNTED ELECTRICAL DEVICES, THE ARCHITECTURAL DRAWINGS SHALL GOVERN. NOTIFY ARCHITECT OF DISCREPANCIES AND OBTAIN WRITTEN CLARIFICATION PRIOR TO PROCEEDING WITH WORK. 15/16.4 SUBMIT ARE SPRINKLER LAYOUT FOR COORDINATION/APPROVAL BY THE OWNER OR THE OWNER'S AGENT. PATTERN OF SPRINKLER LAYOUT SHALL COORDINATE WITH PATTERN OF LIGHTING LAYOUT AND SHALL COORDINATE WITH OTHER CEILING COMPONENTS. 15/16.5 DESIGN/BUILD MECHANICAL CONTRACTOR SHALL PROVIDE DRAWINGS SHOWING THERMOSTAT LOCATION FOR REVIEW BY THE OWNER OR OWNER'S AGENT. 15/16.6 OUTLET/JUNCTION BOX MOUNTING HEIGHTS SHALL BE COORDINATED WITH THE EQUIPMENT/APPLIANCE FOR WHICH IT WAS DESIGNATED. VERIFY EQUIPMENT MOUNTING REQUIREMENTS FOR SCHEDULED - EQUIPMENT. 15/16.7 SWITCHES SHALL BE GANGED UNDER ONE PLATE. DIMMERS SHALL BE In GANGED UNLESS OTHERWISE NOTED BY MANUFACTURER. 15/16.8 DATA AND COMMUNICATION CABLES ARE PROVIDED BY OTHERS AND INSTALLED BY OTHERS UNLESS OTHERWISE NOTED. CONTRACTOR SHALL COORDINATE AT THE BEGINNING OF THE PROJECT WITH THE TENANT AND TENANT'S VENDORS TO DETERMINE THE PHASE DURING WHICH THE INSTALLATION SHALL OCCUR. 15/16.9 DIMENSIONS, IF IDENTIFIED, ARE TO CENTERLINE OF OUTLET OR GANG OF OUTLETS, UNLESS OTHERWISE NOTED. 15/16.10 ALL / SWITCHES AND SWITCHPLAII_S SHALL BE BUILDING STANDARD COLOR UNLESS NOTED OTHERWISE. IF NO BUILDING STANDARD, PROVIDE IVORY. _ 15/16.11 WHERE FLOOR MONUMENTS ARE SHOWN NEXT TO EACH OTHER, THEY SHALL BE LOCATED AS CLOSE TOGETHER AS POSSIBLE, WHILE STILL PROVIDING PROPER ACCESS TO RECEPTACLES. 15/16.12 IF ADDITIONAL OUTLETS REQUIRED, COORDINATE WITH ARCHITECTURAL FOR SPECIFIC LOCATION. 15/16.13 CONTRACTOR SHALL MARK ALL POWER AND COMMUNICATION OUTLET LOCATIONS ON SLAB AND PROVIDE ACCESS TO SITE FOR ARCHITECT TO OBSERVE PRIOR TO ANY COMMENCEMENT OF "ROUGH -IN' CONSTRUCTION. W GN GENERAL NOTES GN.1 CONTRACTOR TO VERIFY DIMENSIONS AND EXISTING CONDITIONS AND RETORT ANY DISCREPANCIES FROM THIS PLAN TO DESIGNER PRIOR TO PROCEEDING WITH CONSTRUCTION. GN.2 DIMENSIONS ARE AS FOLLOWS, UNLESS OTHERWISE NOTED: A. TO FINISHED FACE OF GYPSUM BOARD. '"� B. TO INSIDE FACE OF JAMB AT DOORS AND OTHER OPENINGS. = Z C. TO TOP OF FINISHED FLOORS. F- J C) D. TO BOTTOM OF FINISHED CEILINGS. H W !) 0 GN.3 SEE WALL LEGEND FOR SYMBOLS RELATED TO WALL CONSTRUCTION, c�' , Ls.s c� EXISTING CONSTRUCTION AND WALL TYPES. H GNA TERMINATE WALLS AT UNDERSIDE OF CEILING UNLESS INDICATED ; ` ~' z y � OTHERWISE. GN.5 DO NOT SCALE DRAWINGS. WRITTEN DIMENSIONS GOVERN. PARTITION LOCATIONS, DIMENSIONS AND TYPES, DOOR AND WINDOW LOCATIONS SHALL BE AS SHOWN ON CONSTRUCTION PLAN. IN CASE OF CONFLICT, NOTIFY DESIGNER FOR WRITTEN CLARIFICATION PRIOR TO PROCEEDING Lu 11.1 WITH CONSTRUCTION. .:t_ IBJ C) 4- ) GN.6 CONTRACTOR SHALL PROVIDE CHALK LINES DELINEATING WALL LAYOUT 1 j 5 "`' r +' FOR THE ARCHITECT'S OBSERVATION WITH REGARD TO DESIGN INTENT. LL r : j DO NOT PROCEED WITH INSTALLATION OF STUDS WITHOUT THIS OBSERVATION. �' C % � cc GN.7 FOR BUILT-IN WORK SURROUNDED BY PARTITION, INCLUDING BUT NOT1.1 -j I1! U F- U LIMITED TO APPLIANCES AND FILES, CONTRACTOR SHALL CONFIRM THAT Ll3 f:1:---) FLOOR SLAB DOES NOT VARY BY MORE THAN 1/4' IN 20'-0" NON- CL 1.= ":r ' U'I w�a: �QO CUMULATIVE. NOTIFY DESIGNER IF TOLERANCE IS EXCEEDED. to L'i --C� Uj cn (D }}.. GN.8 CONTRACTOR SHALL COORDINATE PLACEMENT OF BLOCKING PRIOR TO LW p U = W F_ CLOSE -IN OF WALLS. GN.9 SOUND INSULATED AND FIRE RATED PARTITIONING SHALL BE CAULKED AT PERIMETER WITH ACOUSTICAL OR ARE RATED SEALANT AS APPLICABLE PLACE SEALANT BETWEEN GYPSUM BOARD AND ADJACENT SUBSTRATE. PROVIDE WITH SOUND ATTENUATING INSULATION SECURELY FASTENED TO STUD FRAMING. AT THESE PARTITIONS, BACK TO BACK ELECTRICAL JUNCTION BOXES ARE NOT PERMITTED. GN.10 ALL APPLIANCES NOTED ON ELEVATIONS SHALL BE SUPPLIED BY CONTRACTOR. VNVICINI dIHSNAI0L AV -10 /-I�-,61►VO.Jo ol. JC) _ r S3�tnEi3S ALINnvab'UC.)o �.I Sao Ipoo- (? lef3tj Suo►l�I�6a� T P�+e �T''1S To He 400 00uei;dwoo Ol ToafgnS NollonlsrV w,,. �_ a 10036 i vj 03SV3_13d STATE OF - L/CLAY TOWNSHIP Dept. of Community Services -- Building & Code Enforcement One Civic Square I" Floor; Carmel, IN 46032 PLAN AUTHENTICATION CERTIFICATIONS AND AGREEMENT As the authorized agent responsible for obtaining a permit or permits', I certify that these plans are IDENTICAL to those released for construction by the Indiana Dept. of Fire & Building Services. I also understand that if it is determined that these plans are not identical, a STOP a WORK ORDER will be served, a required under the Ordinances referenced below. ,�, h Authorized Signature Printed Name 'Required under Chapter 7, Section 10 of the Carmel City Code, entitled "Building Code" and Section 29.4: and Section 29.4.3 entitled "Administration". Required by Carmel / Clay Township Zoning Ordinance, Sectio 31.1 entitled "Violations and Penalties". -/ 12/3/04 S:Permits /Forms /AuthentSticker11-01 Date CSO #24316 DEMOLITION PLAN SCALE: 1/8"=V-0" NORTH DEMOLITION LEGEND: EXISTING DUPLEX WALL OUTLET TO BE DEMOLISHED EXISTING QUADRAPLEX WALL OUTLET TO BE DEMOLISHED ,`D EXISTING DEDICATED CIRCUIT OUTLET TO BE DEMOLISHED EXISTING IN—FLOOR DUPLEX OUTLET TO BE DEMOLISHED EXISTING IN—FLOOR TELEPHONE OUTLET TO BE DEMOLISHED EXISTING PHONE/DATA WALL OUTLET TO BE DEMOLISHED EXISTING JUNCTION BOX TO BE DEMOLISHED WALL LEGEND: = = = = EXISTING CONSTRUCTION TO BE REMOVED EXISTING PARTITION TO REMAIN DENOTES AREA NOT IN CONTRACT GENERAL DEMOLITION NOTES: A. DEMOLISH EXISTING WALLS THAT ARE SHOWN DASHED, BACK TO A POINT WHEREAS A SMOOTH SURFACE REMAINS FOR INSTALLATION OF NEW FINISHES. B. REMOVE ELECTRICAL AND DEVICE LINES IN WALLS THAT ARE SHOWN DASHED INCLUDING ALL ATTACHED WIRING. DEMOLISH ELECTRICAL DEVICES AND WIRING BACK TO A POINT WHEREAS PROPER PREPARATION FOR NEW FINISHES IS POSSIBLE. SEE ELECTRICAL AND FINISH PLANS FOR MORE INFORMATION. C. REMOVE ALL WALLS, MILLWORK, DOORS, AND DOOR FRAMES AS SHOWN DASHED. D. REMOVE EXISTING FINISHES WHERE NEW FINISHES ARE TO BE INSTALLED. REFERENCE FINISH SHEET, A801, TO COORDINATE LOCATIONS OF NEW FINISHES E. REMOVE ALL EXISTING FLOOR OUTLETS SHOWN. PROVIDE AN EVEN FLOOR SURFACE IN PREPARATION FOR NEW FLOOR FINISH. F. ALL EXISTING BLINDS AT PERIMETER WINDOW LOCATIONS ARE TO BE CLEANED AND REPAIRED IF NECESSARY AT PROJECT COMPLETION. G. SAVE ALL ITEMS REMOVED FROM THE SPACE PER OWNERS DIRECTION UNLESS OTHERWISE NOTED. DEMOLITION PLAN NOTES: DP1 REMOVE DOOR/FRAME. �2P REMOVE SECTION OF WALL AND PREP FOR NEW OPENING. P3 REMOVE CASEWORK. P4 REMOVE COAT ROD AND SHELVES. P5 REMOVE SINK. CAP PLUMBING BEYOND FINISHED SURFACE. P6 REMOVE ICE MAKER. CAP PLUMBING BEYOND FINISHED SURFACE. �P REMOVE SHELVING AND ADJUSTABLE SHELF BRACKETS. P8 REMOVE SIDELIGHT. faun ca M1117 x+ 600 East 96th Street Suite 100 Indianapolis, IN 46240 Phone: 317 808-6000 Fax: 317 808-6797 cso - Architecture Engineering Interiors Landscape Architecture Land Surveying Corporate Office 280 East 96th Street, Suite 200 Indianapolis, Indiana 46240 317.848.7800 FAX 317.574.0957 ®Copyright 2001 LYNN HYN ES INC. g 6945 WARWICK RD, INDIANAPOLIS, IN 46220 OFFICE: (317) 251-4238 CELL: (317) 496-0464 12/3/04 STATE RELEASE SET i O cn r o r o L U J Z Q z Z J O J o o ' Q O0z a F— co Y i Z Q WQ_ O Z ..a-LL H OwQ J W W>Q O Z W Q — Certified By: lit®� ARM a d n m ®036 SYAYIE OF > by AOP o' Drawing Number: D201 Of Sheets Duke Job Number: A/E Job Number: 24316 CONSTRUCTION PLAN SCALE: 1/8"=V-0" WALL LEGEND: NOTES: EXISTING PARTITION TO REMAIN NEW WALL PARTITION ® NEW LOW WALL PARTITION ALL WALLS TO BE W1 UNLESS OTHERWISE NOTED. W1 3-5/8" 25 GAUGE METAL STUDS ®24"O.C. 0 WITH 5/8" GYPSUM WALL BOARD EACH SIDE. WALLS TO EXTEND TO UNDERSIDE OF CEILING. W2 3-5/8" 25 GAUGE METAL STUDS @24"O.C. WITH 5/8" GYPSUM WALL BOARD EACH SIDE. WALLS TO EXTEND TO STRUCTURAL DECK ABOVE. PROVIDE 2 1/2- SOUND INSULATION INSIDE WALL. W3 NOT USED W4 5-5/8" 25 GAUGE METAL STUDS @ 16" O.C. WITH 5/8" GYPSUM WALL BOARD EACH SIDE. WALLS TO EXTEND TO UNDERSIDE OF CEILING. FINISH ALL FACES OF WALL WITH CT1. SEE FINISH PLAN A801 FOR CERAMIC TILE SPECIFICATION. W5 NEW WALL CONSTRUCTION TO MATCH BUILDING STANDARD DEMISING WALL CONSTRUCTION, DENOTES AREA NOT IN CONTRACT DENOTES NEW MILLWORK o NEW DOOR AND FRAME. REFER TO DOOR SCHEDULE NORTH GENERAL CONSTRUCTION NOTES: A. DIMENSIONS ARE FROM FACE OF FINISHED WALL TO FACE OF FINISHED WALL UNLESS NOTED OR SHOWN OTHERWISE. ANY DIMENSION NOT SHOWN OR DEEMED QUESTIONABLE ARE TO BE VERIFIED BY DESIGNER- DO NOT SCALE DRAWINGS. B. PROVIDE WOOD BLOCKING SUPPORTS AS REQUIRED FOR ALL SURFACE MOUNTED ITEMS. C. NEW DOOR AND FRAME NUMBERS CORRESPOND TO ROOM NUMBERS. WHERE MORE THAN ONE DOOR OCCURS IN A ROOM, A SUFFIX HAS BEEN ADDED (ie. 100A). D. REFER TO CONSTRUCTION PLAN LEGEND FOR WALL CONSTRUCTION AND WALL TYPES. E. ALL NEW DOORS TO BE INSTALLED WITH HINGE 6" AWAY FROM WALL. F. APPLY SEALANT AT ALL PLUMBING FIXTURES AT JUNCTURE WITH WALL AND AT ALL COUNTERTOPS AND BACKSPLASH JUNCTURES. G. ALL WALLS SHALL BE CHALKED OFF FOR DESIGNER'S REVIEW OF NEW WALL CONSTRUCTION H. ALL NEW DOORS SHALL ALLOW 12" CLEAR ON PUSH SIDE AND 18" CLEAR ON PULL SIDE OF DOOR UNLESS NOTED OTHERWISE TO MEET CURRENT ADA CODE REGULATIONS I. ALL WALLS SCHEDULED TO REMAIN (I.E. CORE WALLS, AND DEMISING WALLS) SHALL BE PATCHED, REPAIRED AND SANDED SMOOTH IN PREPARATION FOR NEW FINISHES. J. FLOOR SHALL BE CLEANED, SMOOTH AND LEVEL FOR INSTALLATION OF NEW FLOOR FINISHES AS SCHEDULED. K. BUILDING OWNER AND/OR G.C. TO PROVIDE MINIBLINDS AT ALL PERIMETER WINDOWS. EXISTING MINIBLINDS TO BE CLEANED AT COMPLETION OF CONSTRUCTION. L. ALL NEW AND EXISTING FIRE EXTINGUISHER CABINETS TO BE INSTALLED ACCORDING TO CODE. LIFESAFETY CONTRACTOR TO VERIFY PLACEMENT AND COUNT OF FIRE EXTINGUISHERS THROUGHOUT THE SPACE. IF ADDITIONAL FIRE EXTINGUISHER LOCATIONS ARE NEEDED A PLAN MUST BE SUBMITTED TO THE DESIGNER FOR REVIEW OF AESTHETIC PURPOSES ONLY. M. ALL NEW WORKSURFACES TO RECEIVE 2-1/2" GROMMETS. NEW GROMMET LOCATIONS TO BE VERIFIED WITH TENANT IN FIELD AND WITH RESPECT TO NEW ELECTRICAL LAYOUT CONSTRUCTION PLAN NOTES: ALIGN FINISHED FACES. �2 CENTER WALL ON WINDOW MULLIONS AS PER BUILDING STANDARD DETAILS USE SEALANT AT MULLIONS FOR SOUND INSULATION. VERIFY DIMENSION FROM MULLION TO MULLION AND REPORT ANY DISCREPANCIES TO ARCHITECT BEFORE PROCEEDING WITH CONSTRUCTION. REFERENCE DETAIL 9/A601. FP3 NEW OR RELOCATED RECESSED FIRE EXTINGUISHER CABINET TO BE INSTALLED IN WALL AT THIS LOCATION WITH TOP OF CABINET AT 54" AFF. �4 PROVIDE 1/4" COLD COPPER LINES WITH VALVE FOR TENANT SUPPLIED REFRIGERATOR AND COFFEEMAKER. VERIFY EXACT LOCATION OF ALL APPLIANCES, REQUIRING A WATER SOURCE WITH TENANT. �s PROVIDE COAT ROD AND SHELF; REFERENCE DETAIL 8/A601. �s COPIER PROVIDED AND INSTALLED BY TENANT. G.C. TO PROVIDE POWER SOURCE FOR COPY MACHINE. VERIFY ELECTRICAL REQUIREMENTS WITH MFG. MANUAL. UNDERCOUNTER REFRIGERATOR PROVIDED AND INSTALLED BY TENANT. G.C. TO PROVIDE POWER SOURCE FOR REFRIGERATOR. VERIFY ELECTRICAL REQUIREMENTS WITH MANUFACTURER FPa CENTER WALL ON COLUMN LINE. O PROVIDE 25" DEEP GRANITE WORKSURFACE WITH TIMBERLAKE BASE CABINETS AND STAINLESS STEEL SINGLE BOWL SINK. CUSTOM BUILT RECEPTION DESK AND BACK COUNTER WITH GRANITE TRANSACTION TOP, WOOD VENEER FACE, 25" DEEP PLASTIC LAMINATE WORKSURFACE.2 B/B/F PLASTIC LAMINATE STORAGE PEDESTALS AND PLASTIC LAMINATE SUPPORTSASREQUIRED. PROVIDE 25" GRANITE COUNTERTOP WITH TIMBERLAKE BASE CABINETS. E) PROVIDE 25" DEEP GRANITE COUNTERTOPS WITH TIMBERLAKE BASE AND UPPER CABINETS WITH LOCKS. REFERENCE 7/A601 FOR FURTHER INFORMATION. NOT USED. 14 PROVIDE 25" DEEP PLASTIC LAMINATE WORKSURFACE WITH TIMBERLAKE BASE AND UPPER CABINETS. PROVIDE PLASTIC LAMINATE TOP OVER FILE CABINET GROUP. PROVIDE 18" DEEP GRANITE LEDGES WITH HIDDEN SUPPORTS. E) PROVIDE 36" DEEP GLASS COUNTERTOP WITH WOOD BASE CABINETS. PROVIDE WOOD PRESENTATION RAILS. CREATE LIGHT COVE. SEE ELEVATION 1/A601 FOR ADDITIONAL INFORMATION. 101 D4 NG CLEAR :RED GLASS NEW FORMS AND SURFACES DOOR PULLS, DP5200 STAINLESS CLEAR TEM 10I411111I4111 DOOR SCHEDULE CSO W z U Z W O W O Z DOOR DOOR Landscape Architecture FRAME FRAME HARDWARE REMARKS SIZE Q WQ � Z O f— W W Q W F— :2 Z O I— Q W WV)J L5 UQj W 8 g C w=ow m v0 nocna�[[Z�c��o�vclf=i QF-QJWL.��� J N L) (,) fns LJi II 11 II II II II 11 �I I� II II II m a- a- C�� J J J to CL U MC- CL M U (n F- L� .--ALUMINUM FRAME = U F— 300 RECEPTION E X I 3 TING T O R E M A I N — D1 S,CL,PP,MG,CR SEE NOTE 5 301 CLOSET 3'-3" 8'-4" 1 3/4" WOOD D4 — — ST,FP,S SEE NOTE 4 302 HALLWAY EXI 3 TING TO REMAIN z — — — QY 303A CONFERENCE 3'-3" 8'-4" 1 3/4" WOOD D4 — — ST,FP,S SEE NOTE 4 303B CONFERENCE 3'-3" 8'-4" 1 3/4" AL/GL D5 AL D5 ST,FP,S SEE NOTE 4 304A FILE/COPY 3'-0" 8'-4" 1 3/4" WOOD D3 AL D3 L,S Of Sheets 304B FILE/COPY 3'-0" 8'-4" 1 3/4" WOOD D3 AL D3 L,S 307 OFFICE 3'-0" 8'-4" 1 3/4" WOOD D5 AL/GL D5 L,S ALT. SEE NOTE 7 308 OFFICE 3'-0" 8'-4" 1 3/4" WOOD D5 AL/GL D5 L,S ALT. SEE NOTE 7 309 OFFICE S-3" 8'-4" 1 3/4" WOOD D5 AL/GL D5 L,S 310 OFFICE 3'-0" 8'-4" 1 3/4" WOOD D5 AL/GL D5 L,S ALT. SEE NOTE 7 311 OFFICE 3'-0" 8'-4" 1 3/4" WOOD D5 AL/GL D5 L,S ALT. SEE NOTE 7 313 OFFICE 3'-0" 8'-4" 1 3/4" WOOD D5 AL/GL D5 L,S ALT. SEE NOTE 7 314 OFFICE 3'-0" 8'-4" 1 3/4" WOOD D5 AL/GL D5 L,S ALT. SEE NOTE 7 315 OFFICE 3'-0" 8'-4" 1 3/4" WOOD D5 AL/GL D5 L,S ALT. SEE NOTE 7 316 OFFICE S-0" 8'-4" 1 3/4" WOOD D5 AL/GL D5 L,S ALT. SEE NOTE 7 317 OFFICE 3'-0" 8'-4" 1 3/4" WOOD D5 AL/GL D5 L,S ALT. SEE NOTE 7 318 OFFICE S-3" 8'-4" 1 3/4" WOOD D5 AL/GLI D5 L,S 320 OFFICE 3'-0" 8'-4" 1 3/4" WOOD D5 AL/GL D5 L,S ALT. SEE NOTE 7 323 OFFICE 3'-0" 8'-4" 1 3/4" WOOD D5 AL/GL D5 L,S ALT. SEE NOTE 7 324 OFFICE 3'-0" 8'-4" 1 3/4" WOOD D5 AL/GL D5 L,S ALT. SEE NOTE 7 325 STAIRS E X I 3 T I N G T O R E M A I N — — — 326 OFFICE 3'-0" 8'-4" 1 3/4" WOOD I D2 AL/GL D2 L,S 327 OFFICE 3'-0" 8'-4" 1 3/4" WOOD D2 AL/GL D2 L,S 328 OFFICE 3'-0" 8'-4" 1 3/4" WOOD D2 AL/GL D2 L,S 329 OFFICE 3'-0" 8'-4" 1 3/4" WOOD D2 AL/GL D2 L,S 330 OFFICE 3'-0" 8'-4" 1 3/4" WOOD D2 AL/GL D2 L,S 332 OFFICE 3'-0" 8'-4" 1 3/4" WOOD D2 AL/GL D2 L,S 333 OFFICE 3'-0" 8'-4" 1 3/4" WOOD D2 AL/GL D2 L,S 334 OFFICE 3'-0" 8'-4" 1 3/4" WOOD D2 AL/GL D2 L,S 335 OFFICE 3'-0" 8'-4" 1 3/4" WOOD D2 AL/GL D2 L,S 337 OFFICE 3'-0" 8'-4" 1 3/4" WOOD D2 AL/GL D2 L,S 338 OFFICE 3'-0" 8'-4" 1 3/4" WOOD D2 AL/GLI D2 L,S 339 OFFICE 3'-0" 8'-4" 1 3/4" WOOD D2 AL/GL D2 L,S 340 OFFICE 3'-0" 8'-4" 1 3/4" WOOD D2 AL/GL D2 L,S 341A STORAGE 3'-0" 8'-4" 1 3/4" WOOD D3 AL D3 L,S 3418 OFFICE S-0" 8'-4" 1 3/4" WOOD D3 AL D3 L,S 341C OFFICE 3'-0" 8'-4" 1 3/4" WOOD D3 AL D3 L,S 343 STRATEGY 3'-0" 8'-4" 1 3/4" WOOD D3 AL D3 PS,S 351A WAR ROOM 5'-3" 8'-4" 1 3/4" WOOD D4 — — ST,FP,S SEE NOTE 4 351B WAR ROOM 5'-3" 8'-4" 1 3/4" WOOD D4 — — ST,FP,S SEE NOTE 4 352 ELEC ROOM EXI 3 TI NG TO REMAIN — I I— DOOR SCHEDULE NOTES 1. DROVIDE NEW HIGH GRADE LEVER HARDWARE. HARDWARE TO BE ALUMINUM, NATURAL FINISH. 2. CONTRACTOR TO VERIFY DOOR HEIGHT PRIOR TO CONSTRUCTION. 3. COORDINATE KEYING LOCKSETS WITH TENANT. 4. PROVIDE SLIDER TRACK WITH BUMPER STOPS. 5. EXISTING DOORS TO REMAIN. REMOVE APPLIED FILM AND REPLACE DOOR HARDWARE. SEE ELEVATION 1/A601 FOR FURTHER SPECIFICATIONS. 6. PROVIDE COAT HOOKS ON THE BACK SIDES OF ALL OFFICES WITH DOORS. 7. BASE BID IS FOR A CASED OPENING. ALTERNATE IS FOR A SOLID WOOD HINGED DOOR AS SPECIFIED. DOOR ELEVATIONS SCALE: 1/4"=l'—O" D2 ALUMINUM FRAME NATURAL FINISH D5 PAINTED WOOD CSO Architecture ALUMINUM DOOR Landscape Architecture Land Surveying FRAME 280 East 96th Street, Suite 200 = 317.848.7800 FAX 317.574. 0957 ®Copyright 2001 LYNN HYN ES INC. g = INDIANAPOLIS, IN 46220 OFFICE: (317) 251-4238 PAINTED WOOD .--ALUMINUM FRAME w DOOR NATURAL FINISH o j U off. o 00 cr_� o LEVER v n HARDWARE SOLID WOOD DOOR ADA LEVER HARDWARE R Duke REALTION 600 East 96th Street Suite 100 Indianapolis, IN 46240 Phone: 317 808-6000 Fax: 317 808-6797 CSO Architecture Engineering Interiors Landscape Architecture Land Surveying Corporate Office 280 East 96th Street, Suite 200 Indianapolis, Indiana 46240 317.848.7800 FAX 317.574. 0957 ®Copyright 2001 LYNN HYN ES INC. g 6945 WARWICK RD. INDIANAPOLIS, IN 46220 OFFICE: (317) 251-4238 CELL: (317) 496-0464 12/3/04 STATE RELEASE SET avft off. o s cn o o v J Z Q Q J Z o Q a. O o pZ z M3 O QY LUQ- p Z V LjQ W tl>>QLL. E- Ct) 0 Z Z O V Cert' ' yjjPd�� F AR00910036 m STATE OF o° IA g®a®�i00000®05®® Drawing Number: A201 Of Sheets Duke Job Number: A Job Number: 24316 Main ME I — — — — — — — — — — — — — — JL I i I — — — — — — — — — — JL I I I I I — — — — — — — — — — — — — JL — I i REFLECTED CEILING PLAN SCALE: 1/8.=11-011 Uir) NORTH REFLECTED CEILING LEGEND: GENERAL CEILING NOTES: EXISTING 2' X 4' FLUORESCENT FIXTURE TO BE REMOVED EXISTING 2' X 4' FLUORESCENT FIXTURE TO REMAIN NEW OR RELOCATED 2' X 4' FLUORESCENT FIXTURE, TO MATCH BUILDING STANDARD -I----l— NEW DOWNLIGHT FIXTURE. MFG.: GOTHAM, STYLE: DLVADJMR163ACT30LD120 ®� NEW DOWNLIGHT FIXTURE. MFG.: LITHONIA, STYLE: LP6F32TRT277VGEB10607AZ NEW RAIL AND MONOPOINT FIXTURE. MFG.: TECH LIGHT, STYLE: SPROCKET, 70OM03S ®� NEW PENDANT FIXTURE. MFG.: TECH LIGHT, STYLE: METEOR 700FJWS24 RELOCATED CEILING MTD. EXIT LIGHT W/ DIRECTION INDICATION DUAL—LITE t NEW CEILING MTD. EXIT LIGHT W/ DIRECTION INDICATION TO MATCH BUILDING STANDARD. NEW 2 X 2 LAY—IN GRID SUSPENSION SYSTEM EXISTING CEILING GRID AND TILE TO REMAIN. 1 777-7 T NEW TWO WAY SWITCH Tp NEW DIMMER SWITCH T3 NEW THREE—WAY SWITCH NL NIGHTLIGHT LOCATION GYPSUM BOARD CEILING OPEN TO STRUCTURAL DECK ABOVE, PAINT ALL VISIBLE SURFACES PX. LOCATE MECAHNICAL UNITS IN AREAS AWAY FROM OPEN CEILING AREA. ALL WIRING THROUGH OPEN CEILING AREA TO BE INSIDE CONDUIT. A. ALL WALLS GO TO BOTTOM OF CEILING UNLESS OTHERWISE NOTED. B. EACH ROOM TO HAVE INDIVIDUAL SWITCH LOCATED ON WALL AT DOORWAY TO ROOM, TYPICAL UNLESS NOTED OTHERWISE. IN LOCATIONS OF 2 OR MORE SWITCHES IN CLOSE PROXIMITY ARE TO BE CONSOLODATED TO A GANG PLATE CONDITION. C. CONTRACTOR TO VERIFY EXISTING CONDITIONS TO LAYOUT AND REPORT ANY DESCREPANCIES TO ARCHITECT AND/OR DESIGNER BEFORE PROCEEDING WITH CONSTRUCTION. D. MECHANICAL AND ELECTRICAL IS DESIGN—BUILD. DESIGN—BUILD CONTRACTOR TO VERIFY EXISTING CONDITIONS AND COORDINATE DESIGN OF RELOCATED AND NEW DIFFUSERS, SPRINKLER HEADS, FIRE PROTECTION DEVICES, EXIT LIGHTS, EMERGENCY NIGHT LIGHTS AND THERMOSTATS. DESIGN—BUILD CONTRACTOR TO COORDINATE HIS WORK WITH THE LIGHTING PLAN. ALL QUESTIONS ARE TO BE BROUGHT TO THE ATTENTION OF THE DESIGNER BEFORE PROCEEDING. REFER TO MECHANICAL DRAWINGS FOR RELOCATION OF THERMOSTATS. CONTRACTOR TO VERIFY WITH TENANT AND FURNITURE SUPPLIER THERMOSTAT LOCATIONS FOR PANEL LOCATION CONFLICTS BEFORE PROCEEDING. E. ELECTRICAL CONTRACTOR IS RESPONSIBLE FOR DESIGN/BUILD OF ALL SAFETY SYSTEMS. CONTRACTOR IS TO VERIFY QUANTITY AND PLACEMENT OF INDICATED SAFETY DEVICES (EXIT SIGNS, ALARMS, ETC) AND VERIFY CONFORMANCE WITH LOCAL AND STATE CODES. LIFESAFETi CONTRACTOR IS RESPONSIBLE FOR SUBMITTING NECESSARY DRAWINGS FOR REVIEW AND OBTAINING PERMITS. LIFESAFETY CONTRACTOR IS RESPONSIBLE FOR SUBMITTING DRAWINGS TO CSO INTERIORS FOR REVIEW AND COORDINATION OF LOCATION OF DEVICES. CSO INTERIORS REVIEW IS FOR ASTHETIC REVIEW ONLY. F. REMOVE EXISTING CEILING AND GRID COMPLETELY. INSTALL NEW CEILING GRID AND TILE. CEILING TILE TO BE ARMSTRONG DUNE. G. CEILING HEIGHT IS 8'-6" A.F.F. UNLESS OTHERWISE NOTED. I I I I � I I I I I ------J L------------------) L---- I CEILING PLAN NOTES: cPLIGHT FIXTURES TO BE SUSPENDED AT 8"-6" A.F.F. AND GRADUALLY SLOPE UPWARD TOWARD THE SOUTH WALL OF THE ROOM TO 9'-6" A.F.F. ACOUSTICAL CEILING +8'-6" GYPSUM WALL BOARD TO BE PAINTED WHITE. CEILING DETAIL A202 SCALE: 2" = 1'-0» Duke 600 East 96th Street Suite 100 Indianapolis, IN 46240 Phone: (317) 808-6000 Fax: (317) 808-6797 CSO IN Engineering IME MEN Land Surveying la®o® 280 East 96th Street, Suite 200 Indianapolis, Indiana 46240 317.848.7800 FAX 317.574.0957 ®Copyright 200 LYNN HYN ES I®®.®®®.i 6945 WARWICK RD. INDIANAPOLIS, IN 46220 OFFICE: (317) 251-4238 CELL: (317) 496-0464 12/3/04 STATE RELEASE SET m®.®.I C R ■.._ ai Q mmm v V) lm®®®® o v !®®®.s Z I®®i®i J j I®�� Q a Z � I EMEN O O 00 Z 0 0Z - J � O Q YV LU W 0 Z ~�0 N>z D W W Q LL_ � z W - J LL W Certi '9 AR00910036I m STATE OF Drawing Number: A202 Of Sheets Duke Job Number: A/E Job Number: 24316 111 mwmi I�10 0®1 F-.33011110011 ► 1 ® ®010®1 I�►,O11®► SEI i®►,®N I®► t l®► ®1i1��� ® 111 ll i®► �t11 M 1-R ® ®►,®®I ®_® ®®I 1®► t11111111111116-4311111111111110-33 ON 1111116421 I®E®®1®®! 11®► t®®I � ► � r l 111111011011111I ®® I®®®® ®®EI � ®MME®I I®E®ME1 I®®®! 11111I®®®® I®E®®1 IN1 I®1 IMMEMMEM11 I ! ! Main ME I — — — — — — — — — — — — — — JL I i I — — — — — — — — — — JL I I I I I — — — — — — — — — — — — — JL — I i REFLECTED CEILING PLAN SCALE: 1/8.=11-011 Uir) NORTH REFLECTED CEILING LEGEND: GENERAL CEILING NOTES: EXISTING 2' X 4' FLUORESCENT FIXTURE TO BE REMOVED EXISTING 2' X 4' FLUORESCENT FIXTURE TO REMAIN NEW OR RELOCATED 2' X 4' FLUORESCENT FIXTURE, TO MATCH BUILDING STANDARD -I----l— NEW DOWNLIGHT FIXTURE. MFG.: GOTHAM, STYLE: DLVADJMR163ACT30LD120 ®� NEW DOWNLIGHT FIXTURE. MFG.: LITHONIA, STYLE: LP6F32TRT277VGEB10607AZ NEW RAIL AND MONOPOINT FIXTURE. MFG.: TECH LIGHT, STYLE: SPROCKET, 70OM03S ®� NEW PENDANT FIXTURE. MFG.: TECH LIGHT, STYLE: METEOR 700FJWS24 RELOCATED CEILING MTD. EXIT LIGHT W/ DIRECTION INDICATION DUAL—LITE t NEW CEILING MTD. EXIT LIGHT W/ DIRECTION INDICATION TO MATCH BUILDING STANDARD. NEW 2 X 2 LAY—IN GRID SUSPENSION SYSTEM EXISTING CEILING GRID AND TILE TO REMAIN. 1 777-7 T NEW TWO WAY SWITCH Tp NEW DIMMER SWITCH T3 NEW THREE—WAY SWITCH NL NIGHTLIGHT LOCATION GYPSUM BOARD CEILING OPEN TO STRUCTURAL DECK ABOVE, PAINT ALL VISIBLE SURFACES PX. LOCATE MECAHNICAL UNITS IN AREAS AWAY FROM OPEN CEILING AREA. ALL WIRING THROUGH OPEN CEILING AREA TO BE INSIDE CONDUIT. A. ALL WALLS GO TO BOTTOM OF CEILING UNLESS OTHERWISE NOTED. B. EACH ROOM TO HAVE INDIVIDUAL SWITCH LOCATED ON WALL AT DOORWAY TO ROOM, TYPICAL UNLESS NOTED OTHERWISE. IN LOCATIONS OF 2 OR MORE SWITCHES IN CLOSE PROXIMITY ARE TO BE CONSOLODATED TO A GANG PLATE CONDITION. C. CONTRACTOR TO VERIFY EXISTING CONDITIONS TO LAYOUT AND REPORT ANY DESCREPANCIES TO ARCHITECT AND/OR DESIGNER BEFORE PROCEEDING WITH CONSTRUCTION. D. MECHANICAL AND ELECTRICAL IS DESIGN—BUILD. DESIGN—BUILD CONTRACTOR TO VERIFY EXISTING CONDITIONS AND COORDINATE DESIGN OF RELOCATED AND NEW DIFFUSERS, SPRINKLER HEADS, FIRE PROTECTION DEVICES, EXIT LIGHTS, EMERGENCY NIGHT LIGHTS AND THERMOSTATS. DESIGN—BUILD CONTRACTOR TO COORDINATE HIS WORK WITH THE LIGHTING PLAN. ALL QUESTIONS ARE TO BE BROUGHT TO THE ATTENTION OF THE DESIGNER BEFORE PROCEEDING. REFER TO MECHANICAL DRAWINGS FOR RELOCATION OF THERMOSTATS. CONTRACTOR TO VERIFY WITH TENANT AND FURNITURE SUPPLIER THERMOSTAT LOCATIONS FOR PANEL LOCATION CONFLICTS BEFORE PROCEEDING. E. ELECTRICAL CONTRACTOR IS RESPONSIBLE FOR DESIGN/BUILD OF ALL SAFETY SYSTEMS. CONTRACTOR IS TO VERIFY QUANTITY AND PLACEMENT OF INDICATED SAFETY DEVICES (EXIT SIGNS, ALARMS, ETC) AND VERIFY CONFORMANCE WITH LOCAL AND STATE CODES. LIFESAFETi CONTRACTOR IS RESPONSIBLE FOR SUBMITTING NECESSARY DRAWINGS FOR REVIEW AND OBTAINING PERMITS. LIFESAFETY CONTRACTOR IS RESPONSIBLE FOR SUBMITTING DRAWINGS TO CSO INTERIORS FOR REVIEW AND COORDINATION OF LOCATION OF DEVICES. CSO INTERIORS REVIEW IS FOR ASTHETIC REVIEW ONLY. F. REMOVE EXISTING CEILING AND GRID COMPLETELY. INSTALL NEW CEILING GRID AND TILE. CEILING TILE TO BE ARMSTRONG DUNE. G. CEILING HEIGHT IS 8'-6" A.F.F. UNLESS OTHERWISE NOTED. I I I I � I I I I I ------J L------------------) L---- I CEILING PLAN NOTES: cPLIGHT FIXTURES TO BE SUSPENDED AT 8"-6" A.F.F. AND GRADUALLY SLOPE UPWARD TOWARD THE SOUTH WALL OF THE ROOM TO 9'-6" A.F.F. ACOUSTICAL CEILING +8'-6" GYPSUM WALL BOARD TO BE PAINTED WHITE. CEILING DETAIL A202 SCALE: 2" = 1'-0» Duke 600 East 96th Street Suite 100 Indianapolis, IN 46240 Phone: (317) 808-6000 Fax: (317) 808-6797 CSO Architecture Engineering Interiors Landscape Architecture Land Surveying Corporate Office 280 East 96th Street, Suite 200 Indianapolis, Indiana 46240 317.848.7800 FAX 317.574.0957 ®Copyright 200 LYNN HYN ES INC. S 6945 WARWICK RD. INDIANAPOLIS, IN 46220 OFFICE: (317) 251-4238 CELL: (317) 496-0464 12/3/04 STATE RELEASE SET e O C R m m ai Q 3 v V) CD o v Z Q J j Q Q a Z Z oQ 0 O O 00 Z 0 0Z - J � O Q YV LU W 0 Z ~�0 N>z D W W Q LL_ � z W - J LL W Certi '9 AR00910036I m STATE OF Drawing Number: A202 Of Sheets Duke Job Number: A/E Job Number: 24316 i� i BUILDING STANDARD (TIMBERLAKE XXX) UPPER CABINETS W/(2) ADJUSTABLE 1 -6 00 SHELVES AND 4" WIRE PULLS 1-O" N WITH LOCK. 3/4" HARDWOOD PLYWOOD SHELF PAINTED (P1)LAJ 4 \ PAINTED (pW� OD TRIM, COUNTER OP W/ 25" DEEP GRANITE ENTRY +4" BACKSPLASH. (ST1) ENLARGED PLAN 364"D HARDWOOD END SCALE: 1/2" = 1'-0" SUPPORTS (TYP. EACH END) 1-1/411 dia. CHROME ROD Q o Ln NOTE: WHERE SPAN EXCEEDS 4'-0" A CENTER SUPPORT BRACKET IS TO BE USED L BUILDING STANDARD (TIMBERLAKE XXX) LOWER o CABINETS W/(2) ADJUSTABLE = SHELVES AND 4" WIRE PULLS EXISTING DOOR TO REMAIN. WITH LOCK. EXISTING FILM ON DOOR M TO BE REMOVED. to iV 1/2" REVEAL. ZT REALT1r c�oRPow►noN 600 East 96th Street Suite 100 Indianapolis, IN 46240 Phone:(317) 808-6000 Fax: (317) 808-6797 CSO Architecture Engineering Interiors Landscape Architecture 4'-23/" BUILDING STANDARD (TIMBERLAKE XXX) LOWER o CABINETS W/(2) ADJUSTABLE = SHELVES AND 4" WIRE PULLS EXISTING DOOR TO REMAIN. WITH LOCK. EXISTING FILM ON DOOR M TO BE REMOVED. to iV 1/2" REVEAL. ZT REALT1r c�oRPow►noN 600 East 96th Street Suite 100 Indianapolis, IN 46240 Phone:(317) 808-6000 Fax: (317) 808-6797 CSO Architecture Engineering Interiors Landscape Architecture Land Surveying Corporate Office 280 East 96th Street, Suite 200 Indianapolis, Indiana 46240 317.848.7800 FAX 317.574.0957 ®Copyright 2001 LYNN HYN ES INC. S 6945 WARWICK RD. INDIANAPOLIS, IN 46220 OFFICE: (317) 251-4238 CELL: (317) 496-0464 12/3/04 STATE RELEASE SET e O � TQ mm m D O 0 L J J Q Q Q N z W Z oo p O Ooz CN) 3r-zw Q W Q J Q Z !- Q - O to = W CO) >z O o _ H D z � ; W J W Certifies®® R TU AR00910036 STATE OF Drawing Number: A601 Of Sheets Duke Job Number: A/E Job Number: 24316 HALLWAYB2 336 0a P1 FINISH PLAN SCALE: 1/8$f= 1 t-O$t FINISH LEGEND: FLOORCOVERINGS CARPET - DIRECT GLUE c1 MFG: J & J INDUSTRIES PATTERN: TBD COLOR: TBD C2 SISAL - DIRECT GLUE MFG: TBD PATTERN: TBD COLOR: TBD sT1 NOT USED. LIMESTONE sT2 MFG: ARCHITECTURAL BRICK & TILE COLOR: FONTENAY CLAIR FINISH: NATURAL SIZE: 16 X 24 VINYL COMPOSITION TILE VCT1 MFG: ARMSTRONG PATTERN: TBD COLOR: TBD BASE S NATURAL STONE BASE MFG.: STONE DESIGN COLOR: ARMBRUSTER FINISH: POLISHED 62 VINYL BASE -2.5" BASE MANUFACTURER: JOHNSOIN TE COLOR: TBD 63 LIMESTONE BASE MFG: ARCHITECTURAL BRICK & TILE COLOR: FONTENAY CLAIR FINISH: NATURAL SIZE: 4 X 24 WALLCOVERING CT1 MFG: ARCHITECTURAL BRICK & TILE PATTERN: TERRA PLANK COLOR: BRAZILIAN ANTHARACITE SIZE: 2"X24" 4"X24", 6"X24" RANDOM PATTERN PAINT OP1 MFG: SHERWIN WILLIAMS COLOR: SW7010 WHITE DUCK FINISH: EGGSHELL P2 MFG: SHERWIN WILLIAMS COLOR: TBD FINISH: EGGSHELL PLASTIC LAMINATE F-PLTJ MANUFACTURER: FORMICA COLOR: STORM SOLIDZ 3505-58 FINISH: MATTE WOOD STAIN ws1 WOOD STAIN SPECIES: TBD STAIN: TBD SOLID SURFACE F -Fl -j NATURAL STONE MFG: STONE DESIGN COLOR: ARMBRUSTER FINISH: POLISHED NORTH FABRIC Fi MANUFACTURER: DONGHIA PATTERN: MOHAIR VELVET COLOR: 49 MIDNIGHT 72 MANUFACTURER: HBF PATTERN: HBF LEATHER COLOR: TBD GENERAL FINISH NOTES: A. ALL DOORS TO BE FINISHED TO MATCH WS1. B. ALL DOOR FRAMES TO BE FINISHED TO BE ALUMINUM, NATRUAL FINISH. C. ALL WOOD TRIM TO BE FINISHED TO MATCH WS1. D. ALTERNATES WILL NOT BE ACCEPTED WITHOUT WRITTEN APPORVAL OF ARCHITECT. SAMPLES, WHEN APPLICABLE, SHALL BE SUBMITTED FOR REVIEW. E. CARPET TO CARPET AND/OR CARPET TO HARDSURFACE FLOORING TRANSITIONS TO BE FEATHERED AS REQUIRED OR ARE TO BE EASED USING LATEX TO ACHIEVE A SMOOTH TRANSITION FROM FINISH TO FINISH F. G.C. TO SUBMIT SEAMING DIAGRAMS OF ALL NEW CARPETS IN PROJECT SCOPE FOR REVIEW AND APPROVAL BY DESIGNER BEFORE PROCEEDING WITH FLOORING INSTALLATION. G. G.C. TO PROVIDE VINYL REDUCER STRIP TO MATCH VINYL BASE WHERE CARPET AND VINYL TILE TRANSITIONS TAKE PLACE. H. VERIFY THAT MINIBLINDS ARE PROVIDED AT ALL PERIMETER WINDOW LOCATIONS. IF NEW MINIBLINDS ARE REQUIRED, MINIBLINDS ARE TO MATCH BUILDING STANDARD. I. G.C. TO SUBMIT STAINED AND/OR PAINTED SAMPLE OF MILLWORK, TO ARCHITECT AND/OR DESIGNER FOR REVIEW AND APPROVAL, BEFORE PROCEEDING WITH MILLWORK FINISHING PROCESS. J. REFERENCE INTERIOR ELEVATIONS, WHERE PROVIDED, FOR ADDITIONAL FINISH INFORMATION. K En NGUISHER EXPOSED TO MATCH ADJACENTRI SAFACETERS, AND FIRE L. ALL DRYWALL BULKHEADS ARE TO BE PAINTED (PX), UNLESS OTHERWISE NOTED ON REFLECTED CEILING PLANS. M. GROUT COLOR TO BE 100% EPDXY, COLOR TO BE SELECTED BY DESIGNER. FINISH PLAN NOTES: F1 MATCH EXISING FINISHES. ue REA1.TV CORPow►noN 600 East 96th Street Suite 100 Indianapolis, IN 46240 Phone: (317) 808-6000 Fax: (317) 808-6797 ELECTRICAL PLAN SCALE: 1 Xt=1'-0" ELECTRICAL LEGEND: SYMBOL DESCRIPTION NEW DUPLEX WALL OUTLET NEW QUADRAPLEX WALL OUTLET 8D NEW DEDICATED CIRCUIT OUTLET V NEW PHONE/DATA WALL OUTLET (BOX AND PULL STRING) 0 NEW JUNCTION BOX Q NEW FLOOR MOUNTED TOMBSTONE DUPLEX OUTLET ® NEW FLOOR MOUNTED TOMBSTONE TELEPHONE OUTLET NEW TELEPHONE WALL OUTLET (BOX AND PULL STRING) 6ISO NEW ISOLATED GROUND CIRCUIT OUTLET 6GFI NEW GROUND FAULT INTERUPT CIRCUIT OUTLET NORTH GENERAL ELECTRICAL NOTES: A. ELECTRICAL CONTRACTOR TO PROVIDE JUNCTION BOXES WITH BOX PULL AND STRING AT AT PHONE AND DATA LOCATIONS AS INDICATED ON PLANS. COMPLETE PHONE AND DATA SYSTEMS (MATERIAL & LABOR) PROVIDED BY THE TENANT UNLESS OTHERWISE INDICATED. B. ALL CONDUCTORS SHALL BE INSTALLED IN CONDUIT. C. ELECTRICAL CONTRACTOR TO INSURE DEDICATED OUTLETS OR OTHER SPECIAL ELECTRICAL REQUIREMENTS TO BE COMPATIABLE WITH TENANT EQUIPMENT. D. FURNITURE SHOWN ON PLAN FOR REFERENCE ONLY. ELECTRICAL CONTRACTOR TO COORDINATE ELECTRICAL LOCATIONS AND CIRCUITING REQUIREMENTS WITH TENANT AND/OR FURNITURE DEALERSHIP FOR SYSTEMS BASE FEED AND/OR POWER POLES. ELECTRICAL CONTRATOR TO HARDWIRE FURNITURE SYSTEM TO BUILDING POWER SOURCE. E. ALL RECEPTACLES THAT ARE SHOWN DASHED ARE TO BE REMOVED FROM EXISTING WALLS AND SHALL BE PATCHED AND REPAIRED WITH DRYWALL PRIOR TO NEW WALL FINISH. F. ALL WALL MOUNTED OUTLETS AND PHONE/DATA JUNCTION BOXES TO BE MOUNTED ® 18" A.F.F. UNLESS OTHERWISE NOTED. ELECTRICAL PLAN NOTES: 8 PROVIDE DEDICATED POWER FOR COPIER. ELECTRICAL CONTRACTOR TO VERIFY POWER REQUIREMENTS WITH TENANT EQUIPMENT. I O'I ue REALTY CORPORATION 600 East 96th Street Suite 100 Indianapolis, IN 46240 Phone: (317) 808-6000 Fax: (317) 808-6797 � H N • 225 CFM 185 CFM W 800 165 CFM 185 CFM 8•f ,� 1TO NEW H. P. NO NIGHT SET BACK (1 800 N1 -I- 200 \ 115 • CFM \ CFM el r z L N z 145 1000 — 800 _ 800 CFM 600 CFM 80 j 8' 250 250 CFM CFM 600 z z --_---------------- 2nr� 12'o l�j-1 –�J 120E -��-__ 12' 1200 1200 270 270 270 CFM CFM CFM 165 245 Boo 1400 CFM 165 ^MA �I--------I it 1i 11 110 I 175 i i CFM 177 61 CFM (il 800 mil 8'0 800 1400 CFM 14.0 11 I I z N 1800 o _- o • f�J SII 18'0 O (777 a O NO NIGHT SET BACK II II 0— — 8'• 800 8 f r= EiT 800 GENERAL CEILING NOTES: A. ALL WALLS GO TO BOTTOM OF CEILING UNLESS OTHERWISE NOTED. B. EACH ROOM TO HAVE INDIVIDUAL SWITCH LOCATED ON WALL AT DOORWAY TO ROOM, TYPICAL UNLESS NOTED OTHERWISE. IN LOCATIONS OF 2 OR MORE SWITCHES IN CLOSE PROXIMITY ARE TO BE CONSOLODATED TO A GANG PLATE CONDITION. C. CONTRACTOR TO VERIFY EXISTING CONDITIONS TO LAYOUT AND REPORT ANY DESCREPANCIES TO ARCHITECT AND/OR DESIGNER BEFORE PROCEEDING WITH CONSTRUCTION. D. MECHANICAL AND ELECTRICAL IS DESIGN—BUILD. DESIGN—BUILD CONTRACTOR TO VERIFY EXISTING CONDITIONS AND COORDINATE DESIGN OF RELOCATED AND NEW DIFFUSERS, SPRINKLER HEADS, FIRE PROTECTION DEVICES, EXIT LIGHTS, EMERGENCY NIGHT LIGHTS AND THERMOSTATS. DESIGN—BUILD CONTRACTOR TO COORDINATE HIS WORK WITH THE LIGHTING PLAN. ALL QUESTIONS ARE TO BE BROUGHT TO THE ATTENTION OF THE DESIGNER BEFORE PROCEEDING. REFER TO MECHANICAL DRAWINGS FOR RELOCATION OF THERMOSTATS. CONTRACTOR TO VERIFY WITH TENANT AND FURNITURE SUPPLIER THERMOSTAT LOCATIONS FOR PANEL LOCATION CONFLICTS BEFORE PROCEEDING. E. ELECTRICAL CONTRACTOR IS RESPONSIBLE FOR DESIGN/BUILD OF ALL SAFETY SYSTEMS. CONTRACTOR IS TO VERIFY QUANTITY AND PLACEMENT OF INDICATED SAFETY DEVICES (EXIT SIGNS, ALARMS, ETC.) AND VERIFY CONFORMANCE WITH LOCAL AND STATE CODES. LIFESAFETY CONTRACTOR IS RESPONSIBLE FOR SUBMITTING NECESSARY DRAWINGS FOR REVIEW AND OBTAINING PERMITS. LIFESAFETY CONTRACTOR IS RESPONSIBLE FOR SUBMITTING DRAWINGS TO CSO INTERIORS FOR REVIEW AND COORDINATION OF LOCATION OF DEVICES. CSO INTERIORS REVIEW IS FOR ASTHETIC REVIEW ONLY. F. REMOVE EXISTING CEILING AND GRID COMPLETELY. INSTALL NEW CEILING GRID AND TILE. CEILING TILE TO BE ARMSTRONG DUNE. G. CEILING HEIGHT IS 8'-6" A.F.F. UNLESS OTHERWISE NOTED. 165 350 250 250 250 250 250 125 ecru nr.0 PC►I ^MA nL-►u ��.. PC►l 325 CFM 1000 (V� 1000 _ 1000 0 ]Z`-- P= ==I 10 f r Fa FLOOR PLAN -MECHANICAL SCALE: 1/8"=1'_0" NORTH TO BE PAINTED WHITE. CEILING DETAIL A202 SCALE: 2" = 1'-0" 125 CFM 165 CFM LEGEND NEW MECHANICAL WORK EXISTING MECHANICAL PLAN NOTES O Relocate existing diffuser and flex ® Install new return air grille ® Relocate existing thermostat ® Extend Duct and intall new diffuser and flex ® Remove existing diffuser/RAG ® Relocate existing return air grille ® Relocate existing heat pump ® Install new 1.5 ton heat pump for future use 250 CFM 260 CFM 260 CFM 260 CFM 150 CFM se W 0 vJ ' O o v v o a N LF C�oN U"t0 C) Qz0o i__j _ v J ��� o� r. L = � r w, DO = X W(_0��Q •• W c i x c 0 o v Q U z a Q Z I CU J W Q 1 a Z Zo- I O U) O � �O_ Qa o _jZ�� a Qa � WCL 0L LI -j Z LL_ CL 1U6 \\\11111111/l,,, PNTRICl� * No. PE19500281 STATE OF,\ ',� +✓i D � DRAWING NO. M201_ "1Um PLAN -1CCHANIC&