Loading...
HomeMy WebLinkAboutComCheck 3-29-18COMcheck Software Version 4.0.8.1 Envelope Compliance Certificate Project Title: 90.1 (2007) Standard Project Type: Addition Vertical Glazing / Wall Area: 19% Location: Carmel, Indiana Climate Zone: 5a Construction Site: 14454 Communicty Drive Carmel, IN 46033 Owner/Agent: Designer/Contractor: Shawn Curran Curran Architecture 5719 Lawton Loop E. Drive Indianapolis, IN 46216 Project Information Energy Code: The Playschool at Legacy Addition Building Area Floor Area 1-School/University : Nonresidential 2749 Envelope Assemblies Assembly Cavity R-Value Cont. R-Value Proposed U-Factor Budget U- Factor(a) Gross Area or Perimeter Floor 1: Slab-On-Grade:Unheated, Vertical 2 ft., [Bldg. Use 1 - School/University] (c) 169 --- 0.0 0.730 0.730 Exterior Wall 1: Wood-Framed, 16" o.c., [Bldg. Use 1 - School/University] 1673 19.0 7.5 0.043 0.064 Window 1: Metal Frame, Perf. Specs.: Product ID NA, SHGC 0.45, [Bldg. Use 1 - School/University] (b) 217 --- --- 0.300 0.550 Door 1: Glass (> 50% glazing):Metal Frame, Entrance Door, Perf. Specs.: Product ID NA, SHGC 0.45, [Bldg. Use 1 - School/University] (b) 107 --- --- 0.300 0.800 Roof 1: Attic Roof with Wood Joists, [Bldg. Use 1 - School/University] 2243 38.0 0.0 0.027 0.027 (a) Budget U-factors are used for software baseline calculations ONLY, and are not code requirements. (b) Fenestration product performance must be certified in accordance with NFRC and requires supporting documentation. (c) Slab-On-Grade proposed and budget U-factors shown in table are F-factors. Envelope Compliance Statement Compliance Statement: The proposed envelope design represented in this document is consistent with the building plans, specifications, and other calculations submitted with this permit application. The proposed envelope systems have been designed to meet the 90.1 (2007) Standard requirements in COMcheck Version 4.0.8.1 and to comply with any applicable mandatory requirements listed in the Inspection Checklist. Envelope PASSES: Design 6% better than code Project Title: Data filename: The Playschool at Legacy Addition P:\170340 PlaySchool at Legacy Classroom Addition\DOCS\STATE SUBMITTAL\ComCheck.cck Name - Title Signature Date Project Title: Data filename: The Playschool at Legacy Addition P:\170340 PlaySchool at Legacy Classroom Addition\DOCS\STATE SUBMITTAL\ComCheck.cck Report date: 03/29/18 Page 2 of 9 Inspection Checklist Requirements: 100.0% were addressed directly in the COMcheck software COMcheck Software Version 4.0.8.1 Text in the "Comments/Assumptions" column is provided by the user in the COMcheck Requirements screen. For each requirement, the user certifies that a code requirement will be met and how that is documented, or that an exception is being claimed. Where compliance is itemized in a separate table, a reference to that table is provided. Energy Code: 90.1 (2007) Standard Section # & Req.ID Plan Review Complies? Comments/Assumptions 4.2.2 [PR1]1 Plans and/or specifications provide all information with which compliance can be determined for the building envelope and document where exceptions to the standard are claimed. Complies Does Not Not Observable Not Applicable Requirement will be met. Additional Comments/Assumptions: 1 High Impact (Tier 1) 2 Medium Impact (Tier 2) 3 Low Impact (Tier 3) Project Title: Data filename: The Playschool at Legacy Addition P:\170340 PlaySchool at Legacy Classroom Addition\DOCS\STATE SUBMITTAL\ComCheck.cck Report date: 03/29/18 Page 3 of 9 Section # & Req.ID Footing / Foundation Inspection Plans Verified Value Field Verified Value Complies? Comments/Assumptions 5.5.3.3 [FO1]1 Below-grade wall insulation R- value. R-_____ R-_____ Complies Does Not Not Observable Not Applicable See the Envelope Assemblies table for values. 5.5.3.5 [FO3]1 Slab edge insulation R-value. R-_____ Unheated Heated R-_____ Unheated Heated Complies Does Not Not Observable Not Applicable See the Envelope Assemblies table for values. 5.8.1.2 [FO4]1 Slab edge insulation installed per manufacturer’s instructions. Complies Does Not Not Observable Not Applicable Requirement will be met. 5.5.3.5 [FO5]1 Slab edge insulation depth/length. _____ ft _____ ft Complies Does Not Not Observable Not Applicable See the Envelope Assemblies table for values. 5.8.1.7.3 [FO7]1 Insulation in contact with the ground has <=0.3% water absorption rate per ASTM C272. Complies Does Not Not Observable Section # & Req.ID Framing / Rough-In Inspection Plans Verified Value Field Verified Value Complies? Comments/Assumptions 5.4.3.2 [FR1]3 Factory-built fenestration and doors are labeled as meeting air leakage requirements. Fenestration____ _ cfm/ft2 Doors_____ cfm/ft2 Fenestration____ _ cfm/ft2 Doors_____ cfm/ft2 Complies Does Not Not Observable Not Applicable Requirement will be met. 5.5.4.3a [FR8]1 Vertical fenestration U-Factor. U-_____ U-_____ Complies Does Not Not Observable Not Applicable See the Envelope Assemblies table for values. 5.5.4.3b [FR9]1 Skylight fenestration U-Factor. U-_____ U-_____ Complies Does Not Not Observable Not Applicable See the Envelope Assemblies table for values. 5.5.4.4.1 [FR10]1 Vertical fenestration SHGC value. SHGC:_____ SHGC:_____ Complies Does Not Not Observable Not Applicable See the Envelope Assemblies table for values. 5.5.4.4.2 [FR11]1 Skylight SHGC value. SHGC:_____ SHGC:_____ Complies Does Not Not Observable Not Applicable See the Envelope Assemblies table for values. 5.8.2.1, 5.8.2.4 [FR12]2 Section # & Req.ID Insulation Inspection Plans Verified Value Field Verified Value Complies? Comments/Assumptions 5.4.3.1 [IN1]1 All sources of air leakage in the building thermal envelope are sealed, caulked, gasketed, weather stripped or wrapped with moisture vapor-permeable wrapping material to minimize air leakage. Complies Does Not Not Observable Not Applicable Requirement will be met. 5.5.3.1 [IN2]1 Roof R-value. For some ceiling systems, verification may need to occur during Framing Inspection. R-_____ Above deck Metal Attic R-_____ Above deck Metal Attic Complies Does Not Not Observable Not Applicable See the Envelope Assemblies table for values. 5.8.1.2, 5.8.1.3 [IN3]1 Roof insulation installed per manufacturer’s instructions. Blown or poured loose-fill insulation is installed only where the roof slope is <=3 in 12. Complies Does Not Not Observable Not Applicable Requirement will be met. 5.5.3.1.1 [IN5]3 High-albedo roofs meet solar reflectance of 0.70 and thermal emittance of 0.75 or SRI of 82. SR:_____ SRI:_____ Section # & Req.ID Insulation Inspection Plans Verified Value Field Verified Value Complies? Comments/Assumptions 5.8.1.7 [IN14]2 Exterior insulation is protected from damage with a protective material. Verification for exposed foundation insulation may need to occur during Foundation Inspection. Complies Does Not Not Observable Not Applicable Requirement will be met. 5.8.1.7.1 [IN15]2 Attics and mechanical rooms have insulation protected where adjacent to attic or equipment access. Complies Does Not Not Observable Not Applicable Requirement will be met. 5.8.1.7.2 [IN16]2 Foundation vents do not interfere with insulation. Complies Does Not Not Observable Not Applicable Requirement will be met. 5.8.1.8 [IN17]3 Insulation intended to meet the roof insulation requirements cannot be installed on top of a suspended ceiling. Mark this requirement compliant if insulation is installed accordingly. Complies Does Not Not Observable Not Applicable Requirement will be met. Additional Comments/Assumptions: 1 High Impact (Tier 1) 2 Medium Impact (Tier 2) 3 Low Impact (Tier 3) Project Title: Data filename: The Playschool at Legacy Addition P:\170340 PlaySchool at Legacy Classroom Addition\DOCS\STATE SUBMITTAL\ComCheck.cck Report date: 03/29/18 Section # & Req.ID Final Inspection Complies? Comments/Assumptions 5.4.3.3 [FI1]1 Weatherseals installed on all loading dock cargo doors in Climate Zones 4- 8. Complies Does Not Not Observable Not Applicable Exception: Requirement does not apply. Additional Comments/Assumptions: 1 High Impact (Tier 1) 2 Medium Impact (Tier 2) 3 Low Impact (Tier 3) Project Title: Data filename: The Playschool at Legacy Addition P:\170340 PlaySchool at Legacy Classroom Addition\DOCS\STATE SUBMITTAL\ComCheck.cck Report date: 03/29/18 Page 8 of 9 Project Title: Data filename: The Playschool at Legacy Addition P:\170340 PlaySchool at Legacy Classroom Addition\DOCS\STATE SUBMITTAL\ComCheck.cck Report date: 03/29/18 Page 9 of 9 COMcheck Software Version 4.0.8.1 Interior Lighting Compliance Certificate Project Title: 90.1 (2007) Standard Project Type: Addition Construction Site: 14454 Community Drive Carmel, IN 46033 Owner/Agent: Designer/Contractor: Samuel L. Hurt The Engineering Collaborative 2410 Executive Drive Sute 100 Indianapolis, IN 46241 317.636.3941 sam@tec-mep.com Project Information Energy Code: The Play School at Legacy Expansion Allowed Interior Lighting Power A Area Category B Floor Area (ft2) C Allowed Watts / ft2 D Allowed Watts (B X C) 1-101 - Corridor (Common Space Types:Corridor/Transition) 304 0.50 152 2-102 - 3's Room (Common Space Types:Classroom/Lecture/Training) 716 1.40 1002 3-103 - Toilet (Common Space Types:Restrooms) 39 0.90 35 4-104 - Toilet (Common Space Types:Restrooms) 39 0.90 35 5-105 - Storage (Common Space Types:Active Storage) 55 0.80 44 6-106 - Mechanical (Common Space Types:Electrical/Mechanical) 80 1.50 120 7-107 - 4's Room (Common Space Types:Classroom/Lecture/Training) 1101 1.40 1541 8-108 - Storage (Common Space Types:Active Storage) 55 0.80 44 9-109 - Toilet (Common Space Types:Restrooms) 39 0.90 35 10-110 - Toilet (Common Space Types:Restrooms) 39 0.90 35 Total Allowed Watts = 3044 Proposed Interior Lighting Power E (C X D) D Fixture Watt. A Fixture ID : Description / Lamp / Wattage Per Lamp / Ballast B Lamps/ Fixture C # of Fixtures 1-101 - Corridor (Common Space Types:Corridor/Transition) LED L2: 'L2': 2x2 LED Troffer: Other: 1 6 19 Exempt Exemption:Health, Safety Required by Regulation 2-102 - 3's Room (Common Space Types:Classroom/Lecture/Training) E (C X D) D Fixture Watt. A Fixture ID : Description / Lamp / Wattage Per Lamp / Ballast B Lamps/ Fixture C # of Fixtures Exemption:Health, Safety Required by Regulation 5-105 - Storage (Common Space Types:Active Storage) LED L2: 'L2': 2x2 LED Troffer: Other: 1 2 19 Exempt Exemption:Health, Safety Required by Regulation 6-106 - Mechanical (Common Space Types:Electrical/Mechanical) LED L4: 'L4': 2x4 LED Troffer: Other: 1 1 34 34 7-107 - 4's Room (Common Space Types:Classroom/Lecture/Training) LED L1: 'L1': 2x4 LED Troffer: Other: 1 21 60 Exempt Exemption:Health, Safety Required by Regulation 8-108 - Storage (Common Space Types:Active Storage) LED L2: 'L2': 2x2 LED Troffer: Other: 1 2 19 Exempt Exemption:Health, Safety Required by Regulation 9-109 - Toilet (Common Space Types:Restrooms) LED L3: 'L3': LED Wraparound: Other: 1 1 36 Exempt Exemption:Health, Safety Required by Regulation 10-110 - Toilet (Common Space Types:Restrooms) LED L3: 'L3': LED Wraparound: Other: 1 1 36 Exempt Exemption:Health, Safety Required by Regulation Total Proposed Watts = 34 Interior Lighting Compliance Statement Compliance Statement: The proposed interior lighting design represented in this document is consistent with the building plans, specifications, and other calculations submitted with this permit application. The proposed interior lighting systems have been designed to meet the 90.1 (2007) Standard requirements in COMcheck Version 4.0.8.1 and to comply with any applicable mandatory requirements listed in the Inspection Checklist. Samuel L. Hurt Name - Title Signature Date Interior Lighting PASSES: Design 99% better than code Project Title: Data filename: The Play School at Legacy Expansion Y:\2018\18012 - The Play School at Legacy Addition - Carmel, IN\5.0 Design Data\18012 - Play School at Legacy - Addition_MEP COMCheck.cck Report date: 03/29/18 Page 2 of 13 03/29/2018 COMcheck Software Version 4.0.8.1 Exterior Lighting Compliance Certificate Project Title: 90.1 (2007) Standard Project Type: Addition Construction Site: 14454 Community Drive Carmel, IN 46033 Owner/Agent: Designer/Contractor: Samuel L. Hurt The Engineering Collaborative 2410 Executive Drive Sute 100 Indianapolis, IN 46241 317.636.3941 sam@tec-mep.com Project Information Energy Code: The Play School at Legacy Expansion Allowed Exterior Lighting Power A Area/Surface Category B Quantity C Allowed Watts / Unit D Tradable Wattage E Allowed Watts (B X C) Cooridor exit (Main entry/exit) 3 ft of door 30 Yes 90 Classroom exits (Other entry/exit) 9 ft of door 20 Yes 180 Attached canopy 105 ft2 1.25 Yes 131 Total Tradable Watts (a) = Total Allowed Watts = Total Allowed Supplemental Watts (b) = 401 401 20 (a) Wattage tradeoffs are only allowed between tradable areas/surfaces. (b) A supplemental allowance equal to 20 watts may be applied toward compliance of both non-tradable and tradable areas/surfaces. Proposed Exterior Lighting Power E (C X D) D Fixture Watt. A Fixture ID : Description / Lamp / Wattage Per Lamp / Ballast B Lamps/ Fixture C # of Fixtures Cooridor exit ( Main entry/exit 3 ft of door width): Tradable Wattage LED C1: 'C1': LED Downlight: Other: 1 1 14 14 Samuel L. Hurt Name - Title Signature Date Project Title: Data filename: The Play School at Legacy Expansion Y:\2018\18012 - The Play School at Legacy Addition - Carmel, IN\5.0 Design Data\18012 - Play School at Legacy - Addition_MEP COMCheck.cck Report date: 03/29/18 Page 4 of 13 03/29/2018 COMcheck Software Version 4.0.8.1 Mechanical Compliance Certificate Project Title: 90.1 (2007) Standard Project Type: Addition Location: Carmel, Indiana Climate Zone: 5a Construction Site: 14454 Community Drive Carmel, IN 46033 Owner/Agent: Designer/Contractor: Samuel L. Hurt The Engineering Collaborative 2410 Executive Drive Sute 100 Indianapolis, IN 46241 317.636.3941 sam@tec-mep.com Project Information Energy Code: The Play School at Legacy Expansion Mechanical Systems List Quantity System Type & Description Heating: 1 each - Central Furnace, Gas, Capacity = 60 kBtu/h Proposed Efficiency = 92.00% Et, Required Efficiency = 80.00% Et Cooling: 1 each - Split System, Capacity = 30 kBtu/h, Air-Cooled Condenser Proposed Efficiency = 13.00 SEER, Required Efficiency: 13.00 SEER Fan System: FAN SYSTEM 1 -- Compliance (Motor nameplate HP method) : Passes Fans: FAN 1 Supply, Constant Volume, 980 CFM, 0.3 motor nameplate hp 1 F-102 / ACCU-102 (Single Zone): Heating: 1 each - Central Furnace, Gas, Capacity = 80 kBtu/h Proposed Efficiency = 92.00% Et, Required Efficiency = 80.00% Et Cooling: 1 each - Split System, Capacity = 36 kBtu/h, Air-Cooled Condenser Proposed Efficiency = 13.00 SEER, Required Efficiency: 13.00 SEER Fan System: FAN SYSTEM 1 -- Compliance (Motor nameplate HP method) : Passes Fans: FAN 1 Supply, Constant Volume, 980 CFM, 0.3 motor nameplate hp 1 F-107 / ACCU-107 (Single Zone): Mechanical Compliance Statement Compliance Statement: The proposed mechanical design represented in this document is consistent with the building plans, specifications, and other calculations submitted with this permit application. The proposed mechanical systems have been designed to meet the 90.1 (2007) Standard requirements in COMcheck Version 4.0.8.1 and to comply with any applicable mandatory requirements listed in the Inspection Checklist. Samuel L. Hurt Name - Title Signature Date Project Title: Data filename: The Play School at Legacy Expansion Y:\2018\18012 - The Play School at Legacy Addition - Carmel, IN\5.0 Design Data\18012 - Play School at Legacy - Addition_MEP COMCheck.cck Report date: 03/29/18 Page 5 of 13 03/29/2018 Inspection Checklist Requirements: 100.0% were addressed directly in the COMcheck software COMcheck Software Version 4.0.8.1 Text in the "Comments/Assumptions" column is provided by the user in the COMcheck Requirements screen. For each requirement, the user certifies that a code requirement will be met and how that is documented, or that an exception is being claimed. Where compliance is itemized in a separate table, a reference to that table is provided. Energy Code: 90.1 (2007) Standard Section # & Req.ID Plan Review Complies? Comments/Assumptions 4.2.2, 6.4.2 [PR2]1 Plans, specifications, and/or calculations provide all information with which compliance can be determined for the mechanical systems and equipment and document where exceptions to the standard are claimed. Load calculations per acceptable engineering standards and handbooks. Complies Does Not Not Observable Not Applicable Requirement will be met. 4.2.2, 7.4.1 [PR3]1 Plans, specifications, and/or calculations provide all information with which compliance can be determined for the service water heating systems and equipment and document where exceptions to the standard are claimed. Hot water system sized per manufacturer's sizing guide. Complies Does Not Not Observable Not Applicable Requirement will be met. 4.2.2 [PR4]1 Plans, specifications, and/or calculations provide all information with which compliance can be determined for the lighting and electrical systems and equipment and document where exceptions to the standard are claimed. Information provided should include interior lighting power calculations, wattage of bulbs and ballasts, transformers and control devices. Complies Section # & Req.ID Footing / Foundation Inspection Complies? Comments/Assumptions 6.4.3.8 [FO9]3 Freeze protection and snow/ice melting system sensors for future connection to controls. Complies Does Not Not Observable Not Applicable Exception: Requirement does not apply. Additional Comments/Assumptions: 1 High Impact (Tier 1) 2 Medium Impact (Tier 2) 3 Low Impact (Tier 3) Project Title: Data filename: The Play School at Legacy Expansion Y:\2018\18012 - The Play School at Legacy Addition - Carmel, IN\5.0 Design Data\18012 - Play School at Legacy - Addition_MEP COMCheck.cck Report date: 03/29/18 Page 7 of 13 Section # & Req.ID Mechanical Rough-In Inspection Plans Verified Value Field Verified Value Complies? Comments/Assumptions 6.4.1.4, 6.4.1.5 [ME1]2 HVAC equipment efficiency verified. Non-NAECA HVAC equipment labeled as meeting 90.1. Efficiency:_____ Efficiency:_____ Complies Does Not Not Observable Not Applicable See the Mechanical Systems list for values. 6.4.3.4.1 [ME3]3 Stair and elevator shaft vents have motorized dampers that automatically close. Complies Does Not Not Observable Not Applicable Exception: Requirement does not apply. 6.4.3.4.2, 6.4.3.4.3, 6.4.3.4.4 [ME4]3 Outdoor air and exhaust systems have motorized dampers that automatically shut when not in use and meet maximum leakage rates. Check gravity dampers where allowed. Complies Does Not Not Observable Not Applicable Requirement will be met. 6.4.3.4.5 [ME5]3 Ventilation fans >0.75 hp have automatic controls to shut off fan when not required. Complies Does Not Not Observable Not Applicable Requirement will be met. 6.4.3.9 [ME6]1 Section # & Req.ID Mechanical Rough-In Inspection Plans Verified Value Field Verified Value Complies? Comments/Assumptions 6.5.2.3 [ME19]3 Dehumidification controls provided to prevent reheating, recooling, mixing of hot and cold airstreams or concurrent heating and cooling of the same airstream. Complies Does Not Not Observable Not Applicable Requirement will be met. 6.5.4.1 [ME25]3 HVAC pumping systems >10 hp designed for variable fluid flow. Complies Does Not Not Observable Not Applicable Requirement will be met. 6.5.6.1 [ME30]1 Exhaust air energy recovery on systems >=5,000 cfm and 70% of design supply air. Complies Does Not Not Observable Not Applicable Exception: Requirement does not apply. 6.5.7.1 [ME32]2 Kitchen hoods >5,000 cfm have make up air >=50% of exhaust air volume. Complies Does Not Not Observable Not Applicable Exception: Requirement does not apply. 6.5.7.2 [ME33]1 Fume hoods exhaust systems >=15,000 cfm have VAV hood exhaust and supply systems, direct make-up air or heat recovery. Section # & Req.ID Rough-In Electrical Inspection Complies? Comments/Assumptions 9.4.1.1 [EL1]2 Automatic controls to shut off all building lighting installed in buildings >5,000 ft2. Complies Does Not Not Observable Not Applicable Requirement will be met. 9.4.1.2 [EL2]2 Independent lighting controls installed per approved lighting plans and all manual controls readily accessible and visible to occupants. Complies Does Not Not Observable Not Applicable Requirement will be met. 9.4.1.3 [EL3]2 Automatic lighting controls for exterior lighting installed. Complies Does Not Not Observable Not Applicable Requirement will be met. 9.4.1.4 [EL4]1 Separate lighting control devices for specific uses installed per approved lighting plans. Complies Does Not Not Observable Not Applicable Requirement will be met. 9.4.2 [EL5]3 Ballasted one and three lamp fixtures with >30 W/lamp have two lamp tandem wired ballasts when >=2 fixtures in same space on same control. Complies Does Not Not Observable Not Applicable Requirement will be met. 9.4.3 [EL6]1 Exit signs do not exceed 5 watts per face. Section # & Req.ID Final Inspection Complies? Comments/Assumptions 6.4.3.1.1 [FI2]2 Heating and cooling to each zone is controlled by a thermostat control. Complies Does Not Not Observable Not Applicable Requirement will be met. 6.4.3.1.2, 6.4.3.2, 6.4.3.3, 6.4.3.3.1, 6.4.3.3.2 [FI3]2 Thermostatic controls have a 5 °F deadband. Complies Does Not Not Observable Not Applicable Exception: Thermostats requiring manual changeover between heating and cooling. 6.4.3.7 [FI6]3 When humidification and dehumidification are provided to a zone, simultaneous operation is prohibited. Complies Does Not Not Observable Not Applicable Requirement will be met. 6.7.2.1 [FI7]3 Furnished HVAC as-built drawings submitted within 90 days of system acceptance. Complies Does Not Not Observable Not Applicable Requirement will be met. 6.7.2.2 [FI8]3 Furnished O&M manuals for HVAC systems within 90 days of system acceptance. Complies Does Not Not Observable Not Applicable Requirement will be met. 6.7.2.3 [FI9]1 Section # & Req.ID Final Inspection Complies? Comments/Assumptions 6.4.3.3.1 [FI21]1 HVAC systems equipped with at least one automatic shutdown control. Complies Does Not Not Observable Not Applicable Requirement will be met. 6.4.3.3.2 [FI22]1 Setback controls allow automatic restart and temporary operation as required for maintenance. Complies Does Not Not Observable Not Applicable Requirement will be met. Additional Comments/Assumptions: 1 High Impact (Tier 1) 2 Medium Impact (Tier 2) 3 Low Impact (Tier 3) Project Title: Data filename: The Play School at Legacy Expansion Y:\2018\18012 - The Play School at Legacy Addition - Carmel, IN\5.0 Design Data\18012 - Play School at Legacy - Addition_MEP COMCheck.cck Report date: 03/29/18 Page 12 of 13 Project Title: Data filename: The Play School at Legacy Expansion Y:\2018\18012 - The Play School at Legacy Addition - Carmel, IN\5.0 Design Data\18012 - Play School at Legacy - Addition_MEP COMCheck.cck Report date: 03/29/18 Page 13 of 13 An air and/or hydronic system balancing report is provided for HVAC systems serving zones >5,000 ft2 of conditioned area. Complies Does Not Not Observable Not Applicable Exception: Requirement does not apply. 6.7.2.4 [FI10]1 HVAC control systems have been tested to ensure proper operation, calibration and adjustment of controls. Complies Does Not Not Observable Not Applicable Requirement will be met. 8.7.1 [FI16]3 Furnished as-built drawings for electric power systems within 30 days of system acceptance. Complies Does Not Not Observable Not Applicable Requirement will be met. 8.7.2 [FI17]3 Furnished O&M instructions for systems and equipment to the building owner or designated representative. Complies Does Not Not Observable Not Applicable Requirement will be met. 9.2.2.3 [FI18]1 Interior installed lamp and fixture lighting power is consistent with what is shown on the approved lighting plans, demonstrating proposed watts are less than or equal to allowed watts. Complies Does Not Not Observable Not Applicable See the Interior Lighting fixture schedule for values. 9.4.5 [FI19]1 Exterior lighting power is consistent with what is shown on the approved lighting plans, demonstrating proposed watts are less than or equal to allowed watts. Complies Does Not Not Observable Not Applicable See the Exterior Lighting fixture schedule for values. 6.4.3.2 [FI20]1 Temperature controls have setpoint overlap restrictions. Complies Does Not Not Observable Not Applicable Requirement will be met. 1 High Impact (Tier 1) 2 Medium Impact (Tier 2) 3 Low Impact (Tier 3) Project Title: Data filename: The Play School at Legacy Expansion Y:\2018\18012 - The Play School at Legacy Addition - Carmel, IN\5.0 Design Data\18012 - Play School at Legacy - Addition_MEP COMCheck.cck Report date: 03/29/18 Page 11 of 13 Complies Does Not Not Observable Not Applicable Requirement will be met. 9.4.4 [EL7]1 Exterior grounds lighting over 100 W provides >60 lm/W unless on motion sensor or fixture is exempt from scope of code or from external LPD. Complies Does Not Not Observable Not Applicable Requirement will be met. 9.6.2 [EL8]1 Additional interior lighting power allowed for special functions per the approved lighting plans and is automatically controlled and separated from general lighting. Complies Does Not Not Observable Not Applicable Requirement will be met. 10.4.1 [EL9]2 Electric motors meet requirements where applicable. Complies Does Not Not Observable Not Applicable Requirement will be met. Additional Comments/Assumptions: 1 High Impact (Tier 1) 2 Medium Impact (Tier 2) 3 Low Impact (Tier 3) Project Title: Data filename: The Play School at Legacy Expansion Y:\2018\18012 - The Play School at Legacy Addition - Carmel, IN\5.0 Design Data\18012 - Play School at Legacy - Addition_MEP COMCheck.cck Report date: 03/29/18 Page 10 of 13 Complies Does Not Not Observable Not Applicable Exception: Requirement does not apply. 6.5.8.1 [ME34]3 Unenclosed spaces that are heated use only radiant heat. Complies Does Not Not Observable Not Applicable Exception: Requirement does not apply. 6.5.9 [ME35]1 Hot gas bypass limited to: <=240 kBtu/h – 50% >240 kBtu/h – 25% Complies Does Not Not Observable Not Applicable Requirement will be met. 6.5.9 [ME35]1 Hot gas bypass limited to: <=240 kBtu/h – 50% >240 kBtu/h – 25% Complies Does Not Not Observable Not Applicable Requirement will be met. Additional Comments/Assumptions: 1 High Impact (Tier 1) 2 Medium Impact (Tier 2) 3 Low Impact (Tier 3) Project Title: Data filename: The Play School at Legacy Expansion Y:\2018\18012 - The Play School at Legacy Addition - Carmel, IN\5.0 Design Data\18012 - Play School at Legacy - Addition_MEP COMCheck.cck Report date: 03/29/18 Page 9 of 13 Demand control ventilation provided for spaces >500 ft2 and >40 people/1000 ft2 occupant density and served by systems with air side economizer, auto modulating outside air damper control, or design airflow >3,000 cfm. Complies Does Not Not Observable Not Applicable Requirement will be met. 6.4.4.1.1 [ME7]3 Insulation exposed to weather protected from damage. Insulation outside of the conditioned space and associated with cooling systems is vapor retardant. Complies Does Not Not Observable Not Applicable Requirement will be met. 6.4.4.1.2 [ME8]2 HVAC ducts and plenums insulated. R-_____ R-_____ Complies Does Not Not Observable Not Applicable Requirement will be met. 6.4.4.1.3 [ME9]2 HVAC piping insulation thickness. _____ in. _____ in. Complies Does Not Not Observable Not Applicable Requirement will be met. 6.4.4.2.1 [ME10]2 Ducts and plenums sealed based on static pressure and location. Complies Does Not Not Observable Not Applicable Requirement will be met. 6.4.4.2.2 [ME11]3 Ductwork operating >3 in. water column requires air leakage testing. Complies Does Not Not Observable Not Applicable Exception: Requirement does not apply. 6.4.4.2.2 [ME11]3 Ductwork operating >3 in. water column requires air leakage testing. Complies Does Not Not Observable Not Applicable Exception: Requirement does not apply. 1 High Impact (Tier 1) 2 Medium Impact (Tier 2) 3 Low Impact (Tier 3) Project Title: Data filename: The Play School at Legacy Expansion Y:\2018\18012 - The Play School at Legacy Addition - Carmel, IN\5.0 Design Data\18012 - Play School at Legacy - Addition_MEP COMCheck.cck Report date: 03/29/18 Page 8 of 13 Does Not Not Observable Not Applicable Requirement will be met. 6.7.2.4 [PR5]1 Detailed instructions for HVAC systems commissioning included on the plans or specifications for projects >=50,000 ft2. Complies Does Not Not Observable Not Applicable Exception: Requirement does not apply. 8.4.1.1, 8.4.1.2 [PR6]2 Plans, specifications, and/or calculations provide all information with which compliance can be determined for the electrical systems and equipment and document where exceptions are claimed. Feeder connectors sized in accordance with approved plans and branch circuits sized for maximum drop of 3%. Complies Does Not Not Observable Not Applicable Requirement will be met. Additional Comments/Assumptions: 1 High Impact (Tier 1) 2 Medium Impact (Tier 2) 3 Low Impact (Tier 3) Project Title: Data filename: The Play School at Legacy Expansion Y:\2018\18012 - The Play School at Legacy Addition - Carmel, IN\5.0 Design Data\18012 - Play School at Legacy - Addition_MEP COMCheck.cck Report date: 03/29/18 Page 6 of 13 Classroom exits ( Other entry/exit 9 ft of door width): Tradable Wattage LED C1: 'C1': LED Downlight: Other: 1 3 14 42 Attached canopy (105 ft2): Tradable Wattage LED C1: 'C1': LED Downlight: Other: 1 1 14 14 Total Tradable Proposed Watts = 70 Exterior Lighting Compliance Statement Compliance Statement: The proposed exterior lighting design represented in this document is consistent with the building plans, specifications, and other calculations submitted with this permit application. The proposed exterior lighting systems have been designed to meet the 90.1 (2007) Standard requirements in COMcheck Version 4.0.8.1 and to comply with any applicable mandatory requirements listed in the Inspection Checklist. Exterior Lighting PASSES: Design 83% better than code Project Title: Data filename: The Play School at Legacy Expansion Y:\2018\18012 - The Play School at Legacy Addition - Carmel, IN\5.0 Design Data\18012 - Play School at Legacy - Addition_MEP COMCheck.cck Report date: 03/29/18 Page 3 of 13 LED L1: 'L1': 2x4 LED Troffer: Other: 1 16 60 Exempt Exemption:Health, Safety Required by Regulation 3-103 - Toilet (Common Space Types:Restrooms) LED L3: 'L3': LED Wraparound: Other: 1 1 36 Exempt Exemption:Health, Safety Required by Regulation 4-104 - Toilet (Common Space Types:Restrooms) LED L3: 'L3': LED Wraparound: Other: 1 1 36 Exempt Project Title: Data filename: The Play School at Legacy Expansion Y:\2018\18012 - The Play School at Legacy Addition - Carmel, IN\5.0 Design Data\18012 - Play School at Legacy - Addition_MEP COMCheck.cck Report date: 03/29/18 Page 1 of 13 Page 7 of 9 SR:_____ SRI:_____ Complies Does Not Not Observable Not Applicable Requirement will be met. 5.5.3.2 [IN6]1 Above-grade wall insulation R- value. R-_____ Mass Metal Steel Wood R-_____ Mass Metal Steel Wood Complies Does Not Not Observable Not Applicable See the Envelope Assemblies table for values. 5.8.1.2 [IN7]1 Above-grade wall insulation installed per manufacturer’s instructions. Complies Does Not Not Observable Not Applicable Requirement will be met. 5.5.3.4 [IN8]1 Floor insulation R-value. R-_____ Mass Steel Wood R-_____ Mass Steel Wood Complies Does Not Not Observable Not Applicable See the Envelope Assemblies table for values. 5.8.1.1 [IN10]2 Building envelope insulation is labeled with R-value or insulation certificate providing R-value and other relevant data. Complies Does Not Not Observable Not Applicable Requirement will be met. 5.8.1.4 [IN11]2 Eaves are baffled to deflect air to above the insulation. Complies Does Not Not Observable Not Applicable Requirement will be met. 5.8.1.5 [IN12]2 Insulation is installed in substantial contact with the inside surface separating conditioned space from unconditional space. Complies Does Not Not Observable Not Applicable Requirement will be met. 5.8.1.6 [IN13]2 Recessed equipment installed in building envelope assemblies does not compress the adjacent insulation. Complies Does Not Not Observable Not Applicable Requirement will be met. 1 High Impact (Tier 1) 2 Medium Impact (Tier 2) 3 Low Impact (Tier 3) Project Title: Data filename: The Playschool at Legacy Addition P:\170340 PlaySchool at Legacy Classroom Addition\DOCS\STATE SUBMITTAL\ComCheck.cck Report date: 03/29/18 Page 6 of 9 Fenestration products rated in accordance with NFRC. Complies Does Not Not Observable Not Applicable Requirement will be met. 5.8.2.2 [FR13]1 Fenestration products are certified as to performance labels or certificates provided. Complies Does Not Not Observable Not Applicable Requirement will be met. 5.8.2.3, 5.5.3.6 [FR14]2 U-factor of opaque doors associated with the building thermal envelope meets requirements. U-_____ Swinging Nonswinging U-_____ Swinging Nonswinging Complies Does Not Not Observable Not Applicable See the Envelope Assemblies table for values. Additional Comments/Assumptions: 1 High Impact (Tier 1) 2 Medium Impact (Tier 2) 3 Low Impact (Tier 3) Project Title: Data filename: The Playschool at Legacy Addition P:\170340 PlaySchool at Legacy Classroom Addition\DOCS\STATE SUBMITTAL\ComCheck.cck Report date: 03/29/18 Page 5 of 9 Not Applicable Requirement will be met. Additional Comments/Assumptions: 1 High Impact (Tier 1) 2 Medium Impact (Tier 2) 3 Low Impact (Tier 3) Project Title: Data filename: The Playschool at Legacy Addition P:\170340 PlaySchool at Legacy Classroom Addition\DOCS\STATE SUBMITTAL\ComCheck.cck Report date: 03/29/18 Page 4 of 9 Report date: 03/29/18 Page 1 of 9