Loading...
HomeMy WebLinkAbout04110144 Building PlansSCOPE DOCUMENT THE DRAWINGS INDICATE THE GENERAL SCOPE OF THE PROJECT IN TERMS OF DESIGN CONCEPT. AS SCOPE DOCUMENTS, THE DRAWINGS DO NOT NECESSARILY INDICATE OF DESCRIBE ALL WORK REQUIRED FOR FILL PERFORMANCE AND COMPLETION OF THE PROJECT. THE CONTRACTOR AND SUBCONTRACTORS SHALL FURNISH ALL ITEMS OF WORK REQUIRED FOR THE PROPER EXECUTION AND COMPLETION OF THE PROJECT, GENERAL NOTES A. ALL WORK SHALL COMPLY WITH ALL APPLICABLE LOCAL, STATE, AND FEDERAL CODES AND REGULATIONS. B. ALL FINISHES SHALL COMPLY WITH FLAME SPREAD AND SMOKE DEVELOPMENT STANDARDS AS LISTED IN THE UNIFORM FIRE CODE AND THE UNIFORM BUILDING CODE. C. ALL DIMENSIONS ARE FROM FINISHED FACE OF WALL TO FINISHED FACE OF WALL OR FROM FINISHED FACE OF WALL TO FINISHED FACE OF MASONRY OR FROM FINISHED FACE OF MASONRY TO FINISHED FACE OF MASONRY, UNLESS OTHERWISE NOTED. ALL MASONRY DIMENSIONS ARE NOMINAL. D. VERIFY ALL EXISTING CONDITIONS PRIOR TO THE START OF CONSTRUCTION. NOTIFY DESIGNER OR ARCHITECT IMMEDIATELY OF ANY DIMENSIONAL CONFLICTS OR CONFLICTS DUE TO UNKNOWN CONDITIONS. WORK SHALL NOT PROCEED UNTIL CONFLICTS ARE RESOLVED. E. EACH CONTRACTOR SHALL EXAMINE ALL DRAWING SHEETS TO DETERMINE FULL EXTENT OF RESPONSIBILITIES FOR EACH RESPECTIVE TRADE. F. REVIEW ALL DRAWINGS (ARCHITECTURAL, PLUMBING, ELECTRICAL, HVAC) CONCERNING SLEEVES, OUTLETS, BOXES, ANCHORS, VENTS, OPENINGS, ETC. THAT MAY BE REQUIRED. EACH RESPECTIVE TRADE IS RESPONSIBLE FOR PROVIDING AND INSTALLING THESE ITEMS. G. ALL SUBCONTRACTORS SHALL PROVIDE SHOP DRAWINGS TO DESIGNER FOR REVIEW ON PRODUCTS OF WORK PRIOR TO FABRICATION AS REQUESTED. H. WHERE NIC = NOT IN CONTRACT, BY OTHERS OR BY OWNER, THE G.C. SHALL COORDINATE AND VERIFY ANY AND ALL SPECIFIC REQUIREMENTS OF FRAMING, BLOCKING, HOOK-UP, SERVICES, UTILITIES, ETC. WITH THE OWNER, I. G.C. TO TAPE, SPACKLE, AND SAND SMOOTH ALL GYPSUM WALL CONSTRUCTION AND PREPARE WALLS TO RECEIVE FINISHES. J. G.C. TO PROVIDE AND INSTALL ANY MISCELLANEOUS BLOCKING AS REQUIRED FOR AN1Y WALL MOUNTED SHELVING, EQUIPMENT OR ACCESSORIES. K. CONTRACTOR SHALL PROVIDE ALL BARRICADES, DUST PARTITIONS, ETC. AS REQUIRED BY LAW AND AS OTHERWISE REQUIRED. L. EACH CONTRACTOR IS REQUIRED TO REMOVE ALL CARTONS, BOXES, PALLETS, PACKAGING, UNUSED MATERIALS, TRASH AND DEBRIS CAUSED BY HIS WORK FROM THE JOB. M. EACH CONTRACTOR IS RESPONSIBLE FOR PROPER INSTALLATION OF ALL FINISHES SPECIFIED. FINISHES ARE SPECIFIED ONLY, PROPER INSTALLATION METHOD IS TO BE DETERMINED BY CONTRACTOR AND INSTALLER. APPROVAL FOR CONSTRUCTION The Tenant agrees that these drawings and specifications represent the entire scope of work for the improvements to be provided. The Tenant's signature below represents acceptance of the final design. Any changes to this scope of work initiated by the Tenant will cause changes in the total cost to the Tenant and in the completion dote for the project. Tenant -------------- ------ Date -------- FLOOR PLAN PLAN NOTES 1. ALL DOORS TO BE NEW BUILDING STANDARD SOLID CORE WOOD DOORS WITH STEELCRAFT HOLLOW METAL FRAMES. (WEYERHAUSER AUTUMN #32-95 LIGHT BIRCH VENEER). DOORS TO BE STAINED. FRAMES TO BE PAIN TED. ALL DOORS TO HAVE LEVER HANDLES AND LOCK SETS BY BEST ACCESS SYSTEMS. 2. DOOR #1 TO BE WOOD AND GLASS ENTRY DOOR. DOOR #15 TO BE CORRIDOR ENTRY DOOR. 3. CONTRACTOR TO PROVIDE BLOCKING IN ALL LOCATIONS WHERE SHELVING, CABINETRY OR WORKSURFACES ARE SHOWN. 4. BUILDING STANDARD EXTERIOR WINDOW BLINDS TO BE PROVIDED FOR ALL EXTERIOR WINDOWS. 5. ALL EXPOSED CORNERS TO RECEIVE CLEAR PLASTIC CORNER GUARDS. 6. TOWEL AND SOAP DISPENSERS IN RESTROOMS TO BE PROVIDED BY CONTRACTOR. 7. CONTRACTOR TO PROVIDE C EAR CAULKING AROUND ALL DOOR FRAMES WOOD AND METAL) AFTER DOOR FRAMES HAVE EEN ADJUSTED AND SET. 8. CONTRACTOR TO PROVIDE LEG SUPPORT FOR ALL COUNTERTOPS NOT SUPPORTED BY BASE CABINETS. 9. CONTRACTOR TO PROVIDE ALL CODE AND ADA REQUIRED FIXTURES AND ACCESSORIES FOR ROOMS 305 AND 313. 10. ANY FIRE ALARM PULLS AFFECTED BY DEMOLITION TO BE RELOCATED TO NEAREST REMAINING OR NEW WALL. 11. ANY INTERIOR GLAZING REQUIRED TO BE 1/4" LAMINATED SAFETY GLASS. 12. CONTRACTOR TO PROVIDE SHOP DRAWINGS FOR APPROVAL FOR ALL CASEWORK. SHELF FOR MICROWAVE BY TENANT. SUPPORT AS REQUIRED. — (0 N II I I O N I _ I of II II I � I I PLASTIC LAMINATE BASE CABINETS - PL2 CONTRACTOR TO DETERMINE BEST ARRANGEMENT. ELEVATION A SCALE: 1/4"=1'-0" FLOOR PLAN KEYED NOTES 1. NEW WALL CONSTRUCTION TO ALIGN WITH EXISTING COLUMN, WINDOW MULLION, OR EXISTING WALL. 2. CONTRACTOR TO PROVIDE STANDARD MIDSIZE STAINLESS STEEL SINGLE BOWL SINK. 3. CONTRACTOR TO PROVIDE STANDARD LARGE SINGLE BOWL STAINLESS STEEL SINK. 4. CONTRACTOR TO PROVIDE ADJUSTABLE HEAVY DUTY SHELVING - 12" DEEP. CONTRACTOR TO DETERMINE BEST ARRANGEMENT AND SUPPORT. S. NEW DEMISING WALL TO BE FRAMED TO THE DECK AND ROCKED TO THE DECK ON BOTH SIDES. CONTRACTOR TO FINISH DRYWALL UP TO CEILING ONLY ON SUITE SIDE, THEN FIRE TAPE FROM 8'-0" TO DECK ON SUITE SIDE AND FROM 8'-0" UP ON UNFINISHED SIDE. 6. CONTRACTOR TO MATCH NEW PLASTIC LAMINATE WORKTOP - PL1 TO ARC ALONG EXTERIOR WALL. 7. LOCATION FOR FULL-SIZE REFRIGERATOR BY TENANT. CONTRACTOR TO PROVIDE ICE MAKER HOOK-UP. 8. LOCATION FOR PHONE BOARD. 9. LOCATION FOR COPIER BY TENANT. 10. CONTRACTOR TO PROVIDE SLIDING GLASS TRANSACTION COUNTER WITH RECESSED TRACK. TRANSACTION TOP TO EXTEND 12: FROM CENTER OF ARC TO TRACK. 11. CONTRACTOR TO PROVIDE BLOCKING FOR WALL MOUNTED TV. PLASTIC LAMINATE UPPER CABINETS - PL2 - CONTRACTOR TO DETERMINE BEST ARRANGEMENT AND SUPPORT. -SINGLE BOWL LARGE STAINLESS STEEL SINK PLASTIC LAMINATE COUNTER - PL1 W/ BACKSPLASH AND 11/2" RADIUS ON ALL 90 DEG O CORNERS I -OPEN FOR rn FULL-SIZE REFRIGERATOR BY TENANT. CONTRACTOR TO PROVIDE ICE MAKER HOOK-UP. VINYL BASE - VB1 CVA/ CUA/ r ILL ELEVATION D1 SCALE:1 /4*- V-0" I'tUtbIAL - rLL BOX/BOX/FILE ELEVATION El SCALE:1 /4"=1'-0" O I N O I N O I SINK BASE TO BE V BOLTED CLOSED ELEVATION B SCALE:1/4"=1'-0" )TIC LAMINATE NTER - PL1 DEEP W/ GROMMETS AND /2" RADIUS ON ALL )EG CORNERS. PORT AS REQUIRED. VINYL BASE - VB 1 PLASTIC LAMINATE WrSLIDINGNGLASS COUNTER RECESSED TRACKS, 12" DEEP FROM CENTER OF ARC TO TRACK PLASTIC LAMINATE CO NTER - PL1 24' DEEP W/ GROMMETS AND 1 1/2" RADIUS ON ALL 90 EG CORNERS. SUPPORT AS REQUIRED. PLASTIC LAMINATE TRgNSACTION COUNTER - PL3 12 DEEP W/ 90 DEGREE RADIUS CORNERS O I n cD N PLASTIC LAMINATE UPPER CABINETS - PL2 CONTRACTOR TO DETERMINE PEST ARRANGEMENT AND SUPPORT SINGLE BOWL LARGE STAINLESS STEEL SINK PLASTIC LAMINATE COUNTER - PL1 W/ BACKSPLASH AND 11 /2" RADIUS - ON ALL 0 DEG I II CORNERS VINYL BASE - VB1 -PLASTIC LAMINATE BASE CABINETS - PL2 CONTRACTOR TO DETERMINE BEST ARRANGEMENT, DUA/ DUAL FILL ELEVATION D2 SCALE: 1/4"=1'-0" PLA`. PEDI BOX/ DUAL rILL ELEVATION E2 _ SCALE:1 /4"=1'-0" FLOOR PLAN SCALE:1 /8"=1'-0" SCOPE OF WORK 0 UPPER CABINETS - PL2 C) CONTRACTOR TO DETERMINE � LJ OO O N O BEST ARRANGEMENT AND SUPPORT W U z w ♦• J U� o ASD, ADA a ■ - ,•• ♦ N > COUNTER - PL1 RR ; � 30 '� ■ ♦♦♦• 0 Lil 4 A 3 : ■ — Cfl ♦• ♦• o ,OFFICE 3 do<� - 0 1 I06 `" 2w E BREAK 30 t ■ � , O o ♦♦♦� 1 a U i BUSINES co ON ALL 90 DEG ♦ ♦♦♦ g_p CK–OUT II OFFICE 303 9 1 Z11 ■ ■ CORNERS 0000 30 SINGLE BOWL MIDSIZE ■ ♦• 5'–O" N i 0 I •♦•♦ ♦� TECH ® HALL 307 33 1■■■■..■■ft* o o I o ♦♦• 308 `� _ 10 ■ 6 D SINK BASE TO BE O RECEPTION I ■ ♦♦♦ • � � 1 I I 4-0.. CONSULT 2 1 301 N ■ ■ •— 1 HOLD310 o0 C: �n 0 ,r, O0 PLASTIC LAMINATE PLASTIC LAMINATE BASE CABINETS - PL2 LAN CONTRACTOR TO DETERMINE ■ ULTRASOUND HALL SCALE: 1 /4"- V-0" $ j 309 311 STOR o ��■■mmmmmm■■■■■■■■■■m* : 11 11 31 ■ ■ ■ �' U-) 0• In c 2 O �.I coo ■ ■ 00 REV I ■ ■ - ®� I ADAc° 0 3 I ■ ■ RR -I O ■ ■ 313`?= 315 0 ■ �2 8'– 10 ae "'' s tea■ ■■ M In W* ■ HOL 15'-10" 1 IT I 31 SIO . 318 2 ■ _ ULTRASOUND 11 1 4'-0" ■ 0 13 14 31 I Ld 0 EQ U EQUAL ■ 0 ■ ■ 12 1 4AI 1 15 1 ■ `� *a■ 5 ■■■.■.m■■■■■■■■■.■.■m■■.■■■■■■■■■■■■■■■■■■■■ � M* FLOOR PLAN SCALE:1 /8"=1'-0" PLASTIC LAMINATE O COUNTER - PQ 24 DEEP W/ GROMMETS AND 1 1/2" RADIUS ON ALL 90 DEG CORNERS. SUPPORT AS REQUIRED. VINYL BASE - VB1 PLASTIC LAMINATE T12NDEEPIO1N/CO � TES - PL3 RADIUS ON ALL 90 DEG CORNERS PLASTIC LAMINATE COPNTER - PL1 24 DEEP W/ GROMMETS AND I 1 1Q" RADIUS ON ALL 90 DEG CORNERS. rn SUPPORT AS REQUIRED. VINYL BASE - V81 0 I in BOX/BOX/FILE ELEVATION D3 SCALE:1/4"=1'-0" PLASTIC LAMINATE COIIJNTER - PQ 24' DEEP W/ GROMMETS AND 1 1L2" RADIUS ON ALL 90 DEG CORNERS. SUPPORT AS REQUIRED. VINYL BASE - V131 ELEVATION E3 SCALE:1 /4"=1'-0" PLASTIC LAMINATE COY244 DEEP W/ GROMMETS AND 1 1 2" RADIUS ON ALL 90 EG CORNERS. SUPPORT AS REQUIRED. VINYL BASE - V131 WALL TYPE A NO SCALE WAIL LEGEND EXISTING WALL CONSTRUCTION EXISTING WALL CONSTRUCTION TO BE REMOVED. NEW PARTIAL HEIGHT PARTITION NEW GLAZED WALL NEW INSULATED WALL ! X 2 ACOUSTICAL TILE WILDING STANDARD 1SG RADAR MEDIUM TEXTURE V USG DX 15/16" EXPOSED ARID SYSTEM 5/8" METAL STUDS r 16" O.C. /8" GYP.BOARD 0TH SIDES ULL BATT INSULATION " BASE WILDING STANDARD LOOR LINE I I I I Ili/,, GNARL ES ' O o°� ISO. ° o -0 870146 0- 17 STATE OF o ° ° °°!!'DIANA o ° A, °°° CHIT \ z PLASTIC LAMINATE 0 UPPER CABINETS - PL2 C) CONTRACTOR TO DETERMINE � LJ OO O N O BEST ARRANGEMENT AND SUPPORT W U z w PLASTIC LAMINATE J U� o z - � N > COUNTER - PL1 o 0 Lil W/ BACKSPLASH — Cfl rn I o- IZ L ----)z C) M AND 1 1 /2" RADIUS o I 0 U i — co ON ALL 90 DEG Y N I II O U CORNERS 0000 SINGLE BOWL MIDSIZE OSTAINLESS STEEL SINK N I 33 Q o SINK BASE TO BE O I I I o� •N I I BOLTED CLOSED. O � •— �O o0 C: �n VINYL BASE - VB1 ,r, 1-114+ PLASTIC LAMINATE PLASTIC LAMINATE BASE CABINETS - PL2 WARDROBE UNIT - PL2 CONTRACTOR TO DETERMINE BEST ARRANGEMENT. ELEVATION C - TYPICAL SCALE: 1 /4"- V-0" IN PLASTIC LAMINATE O COUNTER - PQ 24 DEEP W/ GROMMETS AND 1 1/2" RADIUS ON ALL 90 DEG CORNERS. SUPPORT AS REQUIRED. VINYL BASE - VB1 PLASTIC LAMINATE T12NDEEPIO1N/CO � TES - PL3 RADIUS ON ALL 90 DEG CORNERS PLASTIC LAMINATE COPNTER - PL1 24 DEEP W/ GROMMETS AND I 1 1Q" RADIUS ON ALL 90 DEG CORNERS. rn SUPPORT AS REQUIRED. VINYL BASE - V81 0 I in BOX/BOX/FILE ELEVATION D3 SCALE:1/4"=1'-0" PLASTIC LAMINATE COIIJNTER - PQ 24' DEEP W/ GROMMETS AND 1 1L2" RADIUS ON ALL 90 DEG CORNERS. SUPPORT AS REQUIRED. VINYL BASE - V131 ELEVATION E3 SCALE:1 /4"=1'-0" PLASTIC LAMINATE COY244 DEEP W/ GROMMETS AND 1 1 2" RADIUS ON ALL 90 EG CORNERS. SUPPORT AS REQUIRED. VINYL BASE - V131 WALL TYPE A NO SCALE WAIL LEGEND EXISTING WALL CONSTRUCTION EXISTING WALL CONSTRUCTION TO BE REMOVED. NEW PARTIAL HEIGHT PARTITION NEW GLAZED WALL NEW INSULATED WALL ! X 2 ACOUSTICAL TILE WILDING STANDARD 1SG RADAR MEDIUM TEXTURE V USG DX 15/16" EXPOSED ARID SYSTEM 5/8" METAL STUDS r 16" O.C. /8" GYP.BOARD 0TH SIDES ULL BATT INSULATION " BASE WILDING STANDARD LOOR LINE I I I I Ili/,, GNARL ES ' O o°� ISO. ° o -0 870146 0- 17 STATE OF o ° ° °°!!'DIANA o ° A, °°° CHIT \ z LLJ z 0 W C) Z03 � LJ OO O N O LUN W U z w n J U� o z - � N > n, o 0 Lil 0 — r- rn I o- IZ L ----)z C) M LL o d I 0 U i — co Y O U Lin 0000 m 33 Q o 0 O o� •N O � of W M 12 LLJ z 0 W C) Z03 � LJ OO Lcl�LJ C N O LUN W U z w n J U� o z - � N U n, o 0 0 — r- rn I �J IZ L ----)z C) M LL o d I o U i — co O Lin 0000 33 I o O o� •N O � •— �O o0 C: �n ,r, 1-114+ o M u7 LLJ L-I IN U o Y � �' U-) 0• In coo 00 of W M 12 LLJ z 0 W m Z03 � LJ OO Lcl�LJ C N O LUN W 5-L-,- z w n J U� o z - U n, o 0 0 Q z>z0� z C 7 IZ I �J IZ L ----)z LL Q _J �- m o U of W M 12 H 0 >- m Z03 O D 1 0]m LUN Ld N I Q U w 0__3 CN V o = - U SHEET NUMBER A 2 1 2 OF 5 SHEETS