HomeMy WebLinkAboutTest Results. JACKSONS GRANT ON CREEKSIDE. L125, B (PERMIT # ), BLOWER DOOR-PASS, DUCT BLASTER-PASS
SITE ID: 389012 LOT: 125 BLOCK: HOUSE: 12336 STREET: AMS CT CITY: CARMEL STATE: IN ZIP: 46032 COUNTY: HAMILTON
ACCOUNT#: 909DAVIN BUILDER: DAVID WEEKLEY HOMES SUBDIVISION: JACKSONS GRANT ON CREEKSIDE COMMUNITY: N/A PLAN: 5886 CHESWICK BST 05/08/2017 PROGRAM:
EFL|D|3Y|100% TESTER: EFL IECC: 2009 CLIMATE ZONE: PROPERTY OWNER: PROPERTY ADDRESS: 12336 AMS CT, CARMEL, IN 46032
TEST: BLOWER DOOR RESULT: PASS TESTER: Kurt Schorsch DATE: 06/01/2018
TEST NAME CORRECTION
NEEDED
BUILDER
VERIFIED
RATER
VERIFIED N/A
5.1 Attic Access Panel (fully gasketed and insulated)X
5.2 Attic drop-down Stair (fully gasketed and insulated)X
5.4 Recessed Lighting Fixtures (ICAT labeled and sealed to drywall)X
5.5 Whole-house Fan (insulated gasketed to the opening X
7.3 Fresh air ventilation installed per program specs X
Blower Door
BUILDING ORIENTATION PROGRAM
VOLUME (CU. FT)
CODE
VOLUME (CU. FT)
PROGRAM
SHELL (SQ. FT)
CODE
SHELL (SQ. FT)
44,068 44,068 9168 9168
PROGRAM
CFM 50
CODE
CFM 50
PROGRAM
ACH 50
CODE
ACH 50
PROGRAM
% of Shell
CODE
% of Shell
BD Target 2,292 5,141 3.12 7 25.00%56.08%
BD Actual 1,709 2.33 2.33 18.64%18.64%
Meter #
Room Pressure Test
Mst Bdrm 0 Bdrm 2 0 Bdrm 3 0 With Respect to OUTSIDE
Bdrm 4 0 Bdrm 5 0 Rm 1 0 MEASURE MAIN BODY WRT OUTSIDE 0
Rm 2 0 Rm 3 0 Other 0 DOMINANT DUCT LEAKAGE WRT OUTSIDE 0
CO Detectors 0 INTERIOR DOOR CLOSURE WRT OUTSIDE 0
Energy Star Qualified Appliances?
Efficient Lighting Package?
60 or > Of Hardwired Lights Must Be CFL Or LED
Low Flow Faucets, Toilets etc?
Programmable Thermostat?
Certified Green Program Level Requires Visual Inspection
Mechanical
System Item Location Manufacturer Name Model #1 Model #2 Model #3 Model #4
SYSTEM 1 WATER HEATER BRADFORD WHITE
SYSTEM 2 WATER HEATER
SYSTEM 3 WATER HEATER
SYSTEM 4 WATER HEATER
SYSTEM 1 FURNACE LENNOX
SYSTEM 1 HVAC OUTDOOR
UNIT OUTSIDE LENNOX
SYSTEM 1 HVAC INDOOR COIL
SYSTEM 1 HVAC AHU (HEAT
PUMP)INTERIOR
SYSTEM 2 FURNACE
SYSTEM 2 HVAC OUTDOOR
UNIT
SYSTEM 2 HVAC INDOOR COIL
SYSTEM 2 HVAC AHU (HEAT
PUMP)
SYSTEM 3 FURNACE
SYSTEM 3 HVAC OUTDOOR
UNIT
SYSTEM 3 HVAC INDOOR COIL
SYSTEM 3 HVAC AHU (HEAT
PUMP)
SYSTEM 4 FURNACE
SYSTEM 4 HVAC OUTDOOR
UNIT
SYSTEM 4 HVAC INDOOR COIL
SYSTEM 4 HVAC AHU (HEAT
PUMP)
BUILDING SPECIFICATIONS
BUILDING CHARACTERISTICS AS DESIGN - VALUES AS BUILT - VALUES COMMMENT
# OF BEDROOMS (REM)3 3
CEILING FLAT (REM)R-38.0 R-38.0
SEALED ATTIC (REM)NA NA
VAULTED CEILING (REM)NA NA
FOUNDATION WALLS (REM)R-0.0 R-0.0
EXPOSED FLOOR (REM)R-0.0 R-0.0
ABOVE GRADE WALLS (REM)R-22.3 R-22.3
DUCT SUPPLY R-VALUE (REM)R-6.0 R-6.0
DUCT RETURN R-VALUE (REM)R-6.0 R-6.0
PROGRAMMABLE THERMOSTATS (PRIF)YES YES
WATER HEATER TYPE (PRIF)CONVENTIONAL CONVENTIONAL
WATER HEATER FUEL TYPE (PRIF)GAS GAS
TEST: BLOWER DOOR RESULT: PASS TESTER: Kurt Schorsch DATE: 06/01/2018
BUILDING SPECIFICATIONS
BUILDING CHARACTERISTICS AS DESIGN - VALUES AS BUILT - VALUES COMMMENT
WATER HEATER SIZE, EFFICIENCY & LOCATION
(PRIF)50 GAL, .65 EF 50 GAL, .65 EF
INFILTRATION (HOUSE LKG) ACH (REM)Htg: 1.37 Clg: 1.37 ELA/100 sf shell Htg: 2.33 Clg: 2.33 ACH @ 50 Pascals
FRESH AIR VENTILATION TYPE (PRIF)AIR CYCLER AIR CYCLER
VENTILATION FAN MANUFACTURER (REM)NA NA
VENTILATION FAN MODEL # (REM)NA NA
VENTILATION FLOW REQUIRED (REM)97 97
VENTILATION EQUIP. RATED CFM (REM)97 97
VENTILATION # OF FANS (REM)NA NA
VENTILATION TIME - HRS/DAY SPECIFIED (REM)3.5 3.5
VENTILATION TIME SET BY HVAC CONTRACTOR -
MINUTES PER HOUR (PRIF)
FRESH AIR VENTILATION FAN WATTS (REM)280 280
MEASURED FAN WATTS OR PER MANUFACTURER'S
SPEC'S (PRIF)
INTERIOR % OF CFL'S (PRIF)90 90
DISHWASHER (PRIF).65 EF .65 EF
REFRIGERATOR (PRIF)N/A N/A
FOUNDATION TYPE (PRIF)
SLAB TYPE (PRIF)
SLAB AREA (PRIF)
SLAB DEPTH (PRIF)
SLAB FULL PERIMETER (PRIF)
SLAB GRADE (PRIF)
FLOW RING (PRIF)
HEATING (REM)Fuel-fired air distribution, Natural Gas,
93.0 AFUE
Fuel-fired air distribution, Natural Gas,
93.0 AFUE
COOLING (REM)Air conditioner, Electric, 13.0 SEER Air conditioner, Electric, 13.0 SEER
AIR-SOURCE HP (REM)NA NA
WATER HEATING (REM)Conventional, Natural Gas, 0.65 EF,
50.0 Gal
Conventional, Natural Gas, 0.65 EF,
50.0 Gal
TEST: DUCT BLASTER RESULT: PASS TESTER: Kurt Schorsch DATE: 06/01/2018
TOTAL CONDITIONED FLOOR AREA
(CFA SQ FT)4,375 4,375
DUCT LEAKAGE TO OUTSIDE % TARGET 3.00%3.00%
TOTAL DUCT LEAKAGE % TARGET 4.00%4.00%
SYSTEM 1 SQ FT. SERVED (CFA)4,375 4,375
SYSTEM 1 DUCT LEAKAGE TO OUTSIDE
(CFM25) TARGET 131 131 SYSTEM 1 DUCT LEAKAGE TO OUTSIDE
(CFM25) ACTUAL 69 SYSTEM 1 DUCT LEAKAGE TO OUTSIDE
(% OF CFA) ACTUAL 1.58%1.58%
SYSTEM 1 TOTAL DUCT LEAKAGE
(CFM25) TARGET 175 175 SYSTEM 1 TOTAL DUCT LEAKAGE
(CFM25) ACTUAL 341 SYSTEM 1 TOTAL DUCT LEAKAGE (% OF
CFA) ACTUAL 7.79%7.79%
SYSTEM 2 SQ FT. SERVED (CFA)0 0
SYSTEM 2 DUCT LEAKAGE TO OUTSIDE
(CFM25) TARGET 0 0 SYSTEM 2 DUCT LEAKAGE TO OUTSIDE
(CFM25) ACTUAL
SYSTEM 2 DUCT LEAKAGE TO OUTSIDE
(% OF CFA) ACTUAL
SYSTEM 2 TOTAL DUCT LEAKAGE
(CFM25) TARGET 0 0 SYSTEM 2 TOTAL DUCT LEAKAGE
(CFM25) ACTUAL
SYSTEM 2 TOTAL DUCT LEAKAGE (% OF
CFA) ACTUAL
SYSTEM 3 SQ FT. SERVED (CFA)0 0
SYSTEM 3 DUCT LEAKAGE TO OUTSIDE
(CFM25) TARGET 0 0 SYSTEM 3 DUCT LEAKAGE TO OUTSIDE
(CFM25) ACTUAL
SYSTEM 3 DUCT LEAKAGE TO OUTSIDE
(% OF CFA) ACTUAL
SYSTEM 3 TOTAL DUCT LEAKAGE
(CFM25) TARGET 0 0 SYSTEM 3 TOTAL DUCT LEAKAGE
(CFM25) ACTUAL
SYSTEM 3 TOTAL DUCT LEAKAGE (% OF
CFA) ACTUAL
SYSTEM 4 SQ FT. SERVED (CFA)0 0
SYSTEM 4 DUCT LEAKAGE TO OUTSIDE
(CFM25) TARGET 0 0 SYSTEM 4 DUCT LEAKAGE TO OUTSIDE
(CFM25) ACTUAL
SYSTEM 4 DUCT LEAKAGE TO OUTSIDE
(% OF CFA) ACTUAL
SYSTEM 4 TOTAL DUCT LEAKAGE
(CFM25) TARGET 0 0 SYSTEM 4 TOTAL DUCT LEAKAGE
(CFM25) ACTUAL
SYSTEM 4 TOTAL DUCT LEAKAGE (% OF
CFA) ACTUAL
TEST: DUCT BLASTER RESULT: PASS TESTER: Kurt Schorsch DATE: 06/01/2018
BUILDING SPECIFICATIONS
BUILDING CHARACTERISTICS AS DESIGN - VALUES AS BUILT - VALUES COMMMENT
DUCT LEAKAGE TO OUTSIDE (REM)0.03 CFM25 / CFA 0.016 CFM25 / CFA
TOTAL DUCT LEAKAGE (REM)0.04 CFM25 / CFA 0.078 CFM25 / CFA
FLOW RING (PRIF)