Loading...
HomeMy WebLinkAboutTest Results. JACKSONS GRANT ON CREEKSIDE. L125, B (PERMIT # ), BLOWER DOOR-PASS, DUCT BLASTER-PASS SITE ID: 389012 LOT: 125 BLOCK: HOUSE: 12336 STREET: AMS CT CITY: CARMEL STATE: IN ZIP: 46032 COUNTY: HAMILTON ACCOUNT#: 909DAVIN BUILDER: DAVID WEEKLEY HOMES SUBDIVISION: JACKSONS GRANT ON CREEKSIDE COMMUNITY: N/A PLAN: 5886 CHESWICK BST 05/08/2017 PROGRAM: EFL|D|3Y|100% TESTER: EFL IECC: 2009 CLIMATE ZONE: PROPERTY OWNER: PROPERTY ADDRESS: 12336 AMS CT, CARMEL, IN 46032 TEST: BLOWER DOOR RESULT: PASS TESTER: Kurt Schorsch DATE: 06/01/2018 TEST NAME CORRECTION NEEDED BUILDER VERIFIED RATER VERIFIED N/A 5.1 Attic Access Panel (fully gasketed and insulated)X 5.2 Attic drop-down Stair (fully gasketed and insulated)X 5.4 Recessed Lighting Fixtures (ICAT labeled and sealed to drywall)X 5.5 Whole-house Fan (insulated gasketed to the opening X 7.3 Fresh air ventilation installed per program specs X Blower Door BUILDING ORIENTATION PROGRAM VOLUME (CU. FT) CODE VOLUME (CU. FT) PROGRAM SHELL (SQ. FT) CODE SHELL (SQ. FT) 44,068 44,068 9168 9168 PROGRAM CFM 50 CODE CFM 50 PROGRAM ACH 50 CODE ACH 50 PROGRAM % of Shell CODE % of Shell BD Target 2,292 5,141 3.12 7 25.00%56.08% BD Actual 1,709 2.33 2.33 18.64%18.64% Meter # Room Pressure Test Mst Bdrm 0 Bdrm 2 0 Bdrm 3 0 With Respect to OUTSIDE Bdrm 4 0 Bdrm 5 0 Rm 1 0 MEASURE MAIN BODY WRT OUTSIDE 0 Rm 2 0 Rm 3 0 Other 0 DOMINANT DUCT LEAKAGE WRT OUTSIDE 0 CO Detectors 0 INTERIOR DOOR CLOSURE WRT OUTSIDE 0 Energy Star Qualified Appliances? Efficient Lighting Package? 60 or > Of Hardwired Lights Must Be CFL Or LED Low Flow Faucets, Toilets etc? Programmable Thermostat? Certified Green Program Level Requires Visual Inspection Mechanical System Item Location Manufacturer Name Model #1 Model #2 Model #3 Model #4 SYSTEM 1 WATER HEATER BRADFORD WHITE SYSTEM 2 WATER HEATER SYSTEM 3 WATER HEATER SYSTEM 4 WATER HEATER SYSTEM 1 FURNACE LENNOX SYSTEM 1 HVAC OUTDOOR UNIT OUTSIDE LENNOX SYSTEM 1 HVAC INDOOR COIL SYSTEM 1 HVAC AHU (HEAT PUMP)INTERIOR SYSTEM 2 FURNACE SYSTEM 2 HVAC OUTDOOR UNIT SYSTEM 2 HVAC INDOOR COIL SYSTEM 2 HVAC AHU (HEAT PUMP) SYSTEM 3 FURNACE SYSTEM 3 HVAC OUTDOOR UNIT SYSTEM 3 HVAC INDOOR COIL SYSTEM 3 HVAC AHU (HEAT PUMP) SYSTEM 4 FURNACE SYSTEM 4 HVAC OUTDOOR UNIT SYSTEM 4 HVAC INDOOR COIL SYSTEM 4 HVAC AHU (HEAT PUMP) BUILDING SPECIFICATIONS BUILDING CHARACTERISTICS AS DESIGN - VALUES AS BUILT - VALUES COMMMENT # OF BEDROOMS (REM)3 3 CEILING FLAT (REM)R-38.0 R-38.0 SEALED ATTIC (REM)NA NA VAULTED CEILING (REM)NA NA FOUNDATION WALLS (REM)R-0.0 R-0.0 EXPOSED FLOOR (REM)R-0.0 R-0.0 ABOVE GRADE WALLS (REM)R-22.3 R-22.3 DUCT SUPPLY R-VALUE (REM)R-6.0 R-6.0 DUCT RETURN R-VALUE (REM)R-6.0 R-6.0 PROGRAMMABLE THERMOSTATS (PRIF)YES YES WATER HEATER TYPE (PRIF)CONVENTIONAL CONVENTIONAL WATER HEATER FUEL TYPE (PRIF)GAS GAS TEST: BLOWER DOOR RESULT: PASS TESTER: Kurt Schorsch DATE: 06/01/2018 BUILDING SPECIFICATIONS BUILDING CHARACTERISTICS AS DESIGN - VALUES AS BUILT - VALUES COMMMENT WATER HEATER SIZE, EFFICIENCY & LOCATION (PRIF)50 GAL, .65 EF 50 GAL, .65 EF INFILTRATION (HOUSE LKG) ACH (REM)Htg: 1.37 Clg: 1.37 ELA/100 sf shell Htg: 2.33 Clg: 2.33 ACH @ 50 Pascals FRESH AIR VENTILATION TYPE (PRIF)AIR CYCLER AIR CYCLER VENTILATION FAN MANUFACTURER (REM)NA NA VENTILATION FAN MODEL # (REM)NA NA VENTILATION FLOW REQUIRED (REM)97 97 VENTILATION EQUIP. RATED CFM (REM)97 97 VENTILATION # OF FANS (REM)NA NA VENTILATION TIME - HRS/DAY SPECIFIED (REM)3.5 3.5 VENTILATION TIME SET BY HVAC CONTRACTOR - MINUTES PER HOUR (PRIF) FRESH AIR VENTILATION FAN WATTS (REM)280 280 MEASURED FAN WATTS OR PER MANUFACTURER'S SPEC'S (PRIF) INTERIOR % OF CFL'S (PRIF)90 90 DISHWASHER (PRIF).65 EF .65 EF REFRIGERATOR (PRIF)N/A N/A FOUNDATION TYPE (PRIF) SLAB TYPE (PRIF) SLAB AREA (PRIF) SLAB DEPTH (PRIF) SLAB FULL PERIMETER (PRIF) SLAB GRADE (PRIF) FLOW RING (PRIF) HEATING (REM)Fuel-fired air distribution, Natural Gas, 93.0 AFUE Fuel-fired air distribution, Natural Gas, 93.0 AFUE COOLING (REM)Air conditioner, Electric, 13.0 SEER Air conditioner, Electric, 13.0 SEER AIR-SOURCE HP (REM)NA NA WATER HEATING (REM)Conventional, Natural Gas, 0.65 EF, 50.0 Gal Conventional, Natural Gas, 0.65 EF, 50.0 Gal TEST: DUCT BLASTER RESULT: PASS TESTER: Kurt Schorsch DATE: 06/01/2018 TOTAL CONDITIONED FLOOR AREA (CFA SQ FT)4,375 4,375 DUCT LEAKAGE TO OUTSIDE % TARGET 3.00%3.00% TOTAL DUCT LEAKAGE % TARGET 4.00%4.00% SYSTEM 1 SQ FT. SERVED (CFA)4,375 4,375 SYSTEM 1 DUCT LEAKAGE TO OUTSIDE (CFM25) TARGET 131 131 SYSTEM 1 DUCT LEAKAGE TO OUTSIDE (CFM25) ACTUAL 69 SYSTEM 1 DUCT LEAKAGE TO OUTSIDE (% OF CFA) ACTUAL 1.58%1.58% SYSTEM 1 TOTAL DUCT LEAKAGE (CFM25) TARGET 175 175 SYSTEM 1 TOTAL DUCT LEAKAGE (CFM25) ACTUAL 341 SYSTEM 1 TOTAL DUCT LEAKAGE (% OF CFA) ACTUAL 7.79%7.79% SYSTEM 2 SQ FT. SERVED (CFA)0 0 SYSTEM 2 DUCT LEAKAGE TO OUTSIDE (CFM25) TARGET 0 0 SYSTEM 2 DUCT LEAKAGE TO OUTSIDE (CFM25) ACTUAL SYSTEM 2 DUCT LEAKAGE TO OUTSIDE (% OF CFA) ACTUAL SYSTEM 2 TOTAL DUCT LEAKAGE (CFM25) TARGET 0 0 SYSTEM 2 TOTAL DUCT LEAKAGE (CFM25) ACTUAL SYSTEM 2 TOTAL DUCT LEAKAGE (% OF CFA) ACTUAL SYSTEM 3 SQ FT. SERVED (CFA)0 0 SYSTEM 3 DUCT LEAKAGE TO OUTSIDE (CFM25) TARGET 0 0 SYSTEM 3 DUCT LEAKAGE TO OUTSIDE (CFM25) ACTUAL SYSTEM 3 DUCT LEAKAGE TO OUTSIDE (% OF CFA) ACTUAL SYSTEM 3 TOTAL DUCT LEAKAGE (CFM25) TARGET 0 0 SYSTEM 3 TOTAL DUCT LEAKAGE (CFM25) ACTUAL SYSTEM 3 TOTAL DUCT LEAKAGE (% OF CFA) ACTUAL SYSTEM 4 SQ FT. SERVED (CFA)0 0 SYSTEM 4 DUCT LEAKAGE TO OUTSIDE (CFM25) TARGET 0 0 SYSTEM 4 DUCT LEAKAGE TO OUTSIDE (CFM25) ACTUAL SYSTEM 4 DUCT LEAKAGE TO OUTSIDE (% OF CFA) ACTUAL SYSTEM 4 TOTAL DUCT LEAKAGE (CFM25) TARGET 0 0 SYSTEM 4 TOTAL DUCT LEAKAGE (CFM25) ACTUAL SYSTEM 4 TOTAL DUCT LEAKAGE (% OF CFA) ACTUAL TEST: DUCT BLASTER RESULT: PASS TESTER: Kurt Schorsch DATE: 06/01/2018 BUILDING SPECIFICATIONS BUILDING CHARACTERISTICS AS DESIGN - VALUES AS BUILT - VALUES COMMMENT DUCT LEAKAGE TO OUTSIDE (REM)0.03 CFM25 / CFA 0.016 CFM25 / CFA TOTAL DUCT LEAKAGE (REM)0.04 CFM25 / CFA 0.078 CFM25 / CFA FLOW RING (PRIF)