Loading...
HomeMy WebLinkAbout16CSO 280 EAST 96TH STREET Suite 200 Indianapolis, Indiana 46240 317.848.7800 FAX 317.574.0957 Architecture Engineering Land Pkrj*V lice *ft Arc Mech re Landscape Architecture Interior Design Space Planing QCQPY69ht 1998 Scope Drawings Res drawings id'iaib Bra gaeooi eaope Of tee pled M wme or drcMeaarai do" awnaept the &;&;lore of the Wft to mwpr oratdbobwoi slanmb and Ms typo d strudw6 mWsAW and elatdwl eydene• The draedrtp do mt nssm* Mowb or dealk oe rah required for ill psrfarn = and caro - 00 at de f4** nurlb of ft Odwlrat On Gro fade dr the gaan i saws "- aabd ar described, be bade awnbaaba doll famish ad Items re*Ad far the paper exeaufbn sad arhpW% of the sunk Project: armel Cent Reflecting Pond City Center Drive & 3rd Avenue Carmel, IN Drawing Title: Details Issue Description: Bids & Construction Drawn By: Keynotes Div. 1 - General Requirements 1.1 THESE GENERAL NOTES ARE ORGANIZED BASED UPON THE CONSTRUCTION SPECIFICATIONS INSTITUTE'S 16 DIVISION FORMAT. THE ORGANIZATION OF THESE GENERAL NOTES INTO DIVISIONS CONFORMS IN GENERAL WITH THE PROJECT MANUAL PREPARED FOR THIS PROJECT. Div. 2 - Site Construction 02300.A FINISH GRADE 02300.B COMPACTED EARTH 02300.0 UNDISTURBED EARTH 02300.D GRANULAR DRAINAGE FILL 02750A CONCRETE SIDEWALK 02782.A UNIT PAVERS - CONCRETE 2" X 18" X 18' NOM.) 02782.8 3/4" BITUMINOUS SETTING BED Div. 3 - Concrete 03300A CONCRETE SLAB; REFERENCE STRUCTURAL DRAWINGS 03300.6 CONCRETE FOOTING; REFERENCE STRUCTURAL DRAWINGS 03300.0 CONCRETE FOUNDATION; REFERENCE STRUCTURAL DRAWINGS 03300.1) STEEL REINFORCEMENT; REFERENCE STRUCTURAL DRAWINGS Div. 4 - Masonry 04050.A HORIZONTAL CONTROL JOINT/ EXISTING RELIEF ANGLE LOCATION 04050.8 VERTICAL CONTROL JOINT 04050.0 STAIN EXISTING BRICK - SEE SPECIFICATION SECTION 09984 04050.1) MORTAR NET 04060A GROUT SOLID 04090A LADDER -TIE HORIZONTAL JOINT REINFORCEMENT 0 16" VERTICALLY 04090.8 FLEXIBLE ANCHOR WITH TRIANGULAR TIE AT 24" O.C. VERTICALLY ON COLUMN AND 36" O.C. HORIZONTALLY ON BEAM 04090.0 VENEER ANCHOR WITH TRIANGULAR TIE AT 16" O.C. VERTICALLY AND 16" O.C. HORIZONTALLY 04090.1) FLEXIBLE SHEET FLASHING WITH WEEPHOLES AT 24' O.C. 04090.E TERMINATION BAR 04210A 4" NOM. FACE BRICK 04210.8 4" NOM. TAPERED 'JACK ARCH' BRICK 04220.A 8" NOM. CONCRETE MASONRY UNIT 04220.8 10" NOM. CONCRETE MASONRY UNIT 04220.0 12" NOM. CONCRETE MASONRY UNIT 04220.0 6" NOM. CONCRETE MASONRY UNIT 04405.A DIMENSION LIMESTONE 04405.8 STRAP ANCHOR 04405.0 ROD ANCHOR 04405.1) EXPANSION ANCHOR 04405.E BITUMINOUS DAMPPROOFING 04405.F S.S. ADJUSTABLE ANGLE 04405.G S.S. ROD 04405.H SHIM & SETTING BUTTONS 04405.1 DIMENSION STONE - SETTING -BED MORTAR 04405.J DIMENSION STONE - POINTING MORTAR 04405.K DIMENSION STONE - SEALANT JOINT AND BACKER ROD 04405.E DIMENSION STONE - FLASHING W WEEP HOLES 0 24" O.C. 04405.M DIMENSION STONE - PAVER (2" X 18' X 18" NOM.) 04405.N DIMENSION STONE - 2 1/2" THICK LIMESTONE NOSfNG 04405.0 DIMENSION STONE - LATEX MODIFIED PORTLAND CEMENT SETTING BED MORTAR Div. 5 - Metals 05120A STRUCTURAL STEEL FRAMING MEMBER; REFERENCE STRUCTURAL DRAWINGS. 05120.8 CONTINUOUS STEEL ANGLE. REFERENCE STRUCTURAL DRAWINGS 05192A PREFABRICATED COLD -FORMED METAL -TRUSSES 05300A STEEL ROOF DECKING; REFERENCE STRUCTURAL DRAWINGS, 05400.A 6' "C" SHAPED 20 GA. STEEL STUDS ® 16" O.C. WITH HORIZONTAL BRIDGING SPACED AT NOT MORE THAN 4'-6' O.C. 05400.E "C" SHAPED STEEL STUD BOX LINTEL (SAME SIZE AND GAUGE AS ADJACENT WALL) 05400.0 LIGHT GAUGE STEEL MEMBER; REFERENCE STRUCTURAL DRAWINGS. 05500.A MISC. STEEL (SEE DRAWINGS FOR SIZES) 05500.13 1-1/2" O.D. PIPE RAIUNG 05500.0 WALL BRACKET WITH CONCEALED ANCHORAGE 05500.D PAINTED STEEL LADDER 05500.E MISC. STEEL CLIP ANGLES AND CONNECTIONS; ATTACH TO TO FRAMING OR TUBE STEEL. Div. 6 - Wood and Plastics 06100.A TREATED WOOD BLOCKING 06100.8 TREATED WOOD SHIM 06100.0 3/4' TREATED PLYWOOD 06100.D 3V8* TREATED PLYWOOD 06200A FINISH CARPENTRY 06400A ARCHITECTURAL WOODWORK 06445A SIMULATED WOOD TRIM - WINDOW CASING FYPON PROF87 ILE500 - PAINTED 06445.8 SIMULATED WOOD TRIM - WINDOW CASING FYPON PROFILE 098800 - PAINTED 06445.0 SIMULATED WOOD TRIM - WINDOW CASING FYPON PROFILE 111031 - PAINTED 10009800)- 06445.D SIMULATED WOOD TRIM - WINDOW CASING FYPON PROFILE PAINTED Div. 7 - Thermal and Moisture Protection 07110.A BITUMINOUS DAMPPROOFING 07210.A 1/2" EXTRUDED POLYSTYRENE INSULATION 07210.8 5 MIL POLYETHYLENE VAPOR RETARDER 07210.0 R-11 UNFACED GLASS FIBER BATT INSULATION 07210.D R-19 UNFACED GLASS FIBER BATT INSULATION 07210.E COMPRESSIBLE INSULATION - FILL ENTIRE PERIMETER 07210.F CHICKEN WIRE ON EXTERIOR FACE OF STUD TO HOLD INSULATION IN PLACE 07214A FOAMED -IN-PLACE INSULATION 07270.A AIR INFILTRATION BARRIER - LAP OVER FLEXIBLE SHEET FLASHING, WHERE APPLICABLE; SEAL FLASHING TO SHEATHING: SEAL AIR INFILTRATION BARRIER TO FLASHING. 07311.A ASPHALT SHINGLES 07311.6 ASPHALT UNDERLAYMENT 07311.0 ICE PROTECTION UNDERLAYMENT 07550A MODIFIED BITUMEN ROOFING SYSTEM - HOT MOPPED 07550.13 MODIFIED BITUMEN ROOFING SYSTEM - CANT STRIP 07550.0 MODIFIED BITUMEN ROOFING SYSTEM - FLASHING 07550.D MODIFIED BITUMEN ROOFING SYSTEM - 1 UNIFORM THICKNESS BOARD ROOF INSULATION 07550.E MODIFIED BITUM N ROOFING SYSTEM - TAPERED ROOF INSULATION BOARD; 1/4" PER FOOT SLOPE; 1 2' MINIMUM THICKNESS 07600A 20 OZ. COPPE COUNTER FLASHING ASSEMBLY 07600.B COPPER GUTTER 07600.0 COPPER DOWNSPOUT AND HANGER 07600.1) COPPER SCUPPER 07600.E COPPER FLASHING 07600.17 CONCRETE SPLASH SACK 0760O.G COPPER CONDUCTOR BOX 0761O.A METAL ROOFING - COPPER 07610.8 METAL ROOFING - COPPER - BUILDING PAPER SLIP SHEET 07610.0 METAL ROOFING - COPPER - ORGANIC FELTS 07610.D -G NOT USED 07610.H METAL ROOFING - COPPER - 20 OZ. CLEAT 07610.1 METAL ROOFING - COPPER - 20 OZ. MANSARD RIDGE FLASHING 07610.J METAL ROOFING - COPPER - 20 OZ. VERTICAL SEAM CLEAT BEYOND 0761O.K METAL ROOFING - COPPER - 20 OZ. COMBINATION MANSARD FASCIA / GRAVEL STOP 07610.E METAL ROOFING - COPPER - SOLDERED SEAM 07840.A FIRESTOPPING / FIRE SAFING INSULATION 07900.A SEALANT JOINT WITH BACKER ROD 07900.8 SEALANT Div. 8 - Doors and Windows 08110.A STEEL DOOR 08111A STEEL DOOR FRAME 08111.8 DOOR JAMB ANCHORS -THREE 3 PER JAMB 08212.A STILE AND RAIL WOOD DOOR; ALTERNATE MATERIAL: METAL 08212.8 WOOD FRAME - JAMB; ALTERNATE MATERIAL: METAL 08310A ACCESS DOOR WITH DRYWALL BEAD 08552.A WOOD WINDOWS - EXTERIOR POLYUREA COATING; ALTERNATE MATERIAL: METAL 08552.B WOOD BRICK MOULD; ALTERNATE MATERIAL: METAL 08800A 5/8" CLEAR INSULATING GLASS 08800.8 1/4" CLEAR TEMPERED GLASS. 08800.0 1/4 CLEAR FLOAT GLASS Div. 9 - Finishes 09252A 5/8" SURFACED EXTERIOR GYPSUM SHEATHING 09260.A 5/8" GYPSUM WALLBOARD, USE TYPE 'X' FOR RATED ASSEMBLIES. 09260.6 3 5/8" 25 GA. STEEL STUDS AT 16" O.C. 09260.0 METAL STUD BOX LINTEL (SAME SIZE AND GA. AS ADJACENT WALL) 09260.D METAL J" MOLD. 09260.E 3/4- FURRING AT 131 2" O.C. AND 1 1/2" RUNNER AT 48" O.C. 09260.E METAL CEILING SUSPEN ON SYSTEM SOUND ATTENUATION BLANKETS 09260.G 5/8" GYPSUM SOFFIT BOARD D9260.H 2 1 2' 25 GA. STEEL STUDS AT 16" O.C. 09260.1 6" 5 GA. STEEL STUDS AT 16" O.C. 09260.J 7/8- 25 GA. STEEL FURRING CHANNELS 0? 16" O.C. MAX. 09383A INTERIOR SLATE - STOOLS 09650.A VINYL BASE - SEE FINISH PLAN. 09650.8 VINYL TRANSITION STRIP AT FLOOR MATERIAL CHANGES. 09900A PAINTING AND BACK -PRIMING, WHERE APPLICABLE 09911 A ELECTROSTATIC PAINTING Div. 10 - Specialties 10210A LOUVERS - WALL (FINISH TO MATCH COPPER ROOF ELEMENTS) 10290.A BIRD CONTROL 10340.A CUPOLA 10340.8 CUPOLA FRAMING - SEE STRUCTURAL DRAWINGS 10340.0 ARCHITECTURAL WOOD TRIM 10340.D CUPOLA WINDOW SYSTEM - EXTERIOR POLYUREA COATING 10340.E CUPOLA ROOFING SYSTEM - COPPER FLAT SEAM Div. 11 - Equipment NOT USED Div. 12 - Furnishings 12481A ENTRANCE MATS - SURFACE MOUNTED Div. 13 - Special Construction NOT USED Div. 14 - Conveying Systems NOT USED Div. 15 - Mechanical 15000A ROOF DRAIN; REFERENCE PLUMBING DRAWINGS 15000.E OVERFLOW ROOF DRAIN; REFERENCE PLUMBING DRAWINGS Key Plan J1111111i1111111111111 1J, H, SHOWN 1/A205 SHOWN 1/A205 OPP. HAND H H M E CSO 280 EAST 96TH STREET Suite 200 Indianapolis, Indiana 46240 317.848.7800 FAX 317.574.0957 Architecture Engineering Land Pkrj*V lice *ft Arc Mech re Landscape Architecture Interior Design Space Planing QCQPY69ht 1998 Scope Drawings Res drawings id'iaib Bra gaeooi eaope Of tee pled M wme or drcMeaarai do" awnaept the &;&;lore of the Wft to mwpr oratdbobwoi slanmb and Ms typo d strudw6 mWsAW and elatdwl eydene• The draedrtp do mt nssm* Mowb or dealk oe rah required for ill psrfarn = and caro - 00 at de f4** nurlb of ft Odwlrat On Gro fade dr the gaan i saws "- aabd ar described, be bade awnbaaba doll famish ad Items re*Ad far the paper exeaufbn sad arhpW% of the sunk Project: armel Cent Reflecting Pond City Center Drive & 3rd Avenue Carmel, IN Drawing Title: Details Issue Description: Bids & Construction Date: Drawn By: Checked By: Issue JSW Date: Drawn By: Checked By: 09J17J01 JSW Revisions: +l I Cert ified By: Drawing Numbe r: 20507A205 Drawing Number: