HomeMy WebLinkAboutA000.76:12
6:12
8:12
8:12
4:12
6:12
4:12
8:12
8:12"A"
2026ROOF AREA:
SQ. FT.
GUTTER AND DOWNSPOUTS 6:12
"B"
435ROOF AREA:
SQ. FT.
8:12
8:12
H E A R T L A N D 2 N
A T T I C V E N T S C H E D U L E
R O O F A R E A "A "
SQ
F
T
G
20
2
6
A T / N E A R R I D G E
A T / N E A R E A V E
VE
N
T
T
Y
P
E
SQ
.
F
T
.
RE
Q
U
I
R
E
D
RA
N
G
E
SQ
.
F
T
.
SU
P
P
L
I
E
D
PE
R
C
E
N
T
OF
T
O
T
A
L
SU
P
P
L
I
E
D
PO
T
L
A
R
G
E
(S
Q
.
I
N
.
E
A
C
H
)
PO
T
S
M
A
L
L
(S
Q
.
I
N
.
E
A
C
H
)
RID
G
E
V
E
N
T
(S
Q
.
I
N
.
P
E
R
L
F
)
EA
V
E
V
E
N
T
(SQ
.
I
N
.
E
A
C
H
)
CO
N
T
.
V
E
N
T
(S
Q
.
I
N
.
P
E
R
L
F
)
61
.
0
0
40
.
0
0
18
.
0
0
28
.
0
0
10
.
0
0
P O T V E N T S O N L Y
2.7
0
3.
3
8
3.
3
9
49
.
3
9
8
0
AT
E
A
V
E
4.0
5
3.
3
8
3.
4
7
50
.
6
1
0
50
.
0
0
TO
T
A
L
(M
I
N
)
6.
7
5
6.
7
5
6.
8
6
10
0
.
0
0
RID
G
E
VE
N
T
2.7
0
3.
3
8
3.
3
8
49
.
2
9
0
0
27
.
0
0
AT
E
A
V
E
4.0
5
3.
3
8
3.
4
7
50
.
7
1
0
50
.
0
0
TO
T
A
L
(M
I
N
)
6.
7
5
6.
7
5
6.
8
5
10
0
.
0
0
A D D I T I O N A L P O T V E N T S M A Y B E R E Q U I R E D I F T H E R E I S I N S U F F I C I E N T R I D G E A V A I L A B L E
R O O F A R E A "B "
SQ
F
T
G
43
5
A T / N E A R R I D G E
A T / N E A R E A V E
VE
N
T
T
Y
P
E
SQ
.
F
T
.
RE
Q
U
I
R
E
D
RA
N
G
E
SQ
.
F
T
.
SU
P
P
L
I
E
D
PE
R
C
E
N
T
OF
T
O
T
A
L
SU
P
P
L
I
E
D
PO
T
L
A
R
G
E
(S
Q
.
I
N
.
E
A
C
H
)
PO
T
S
M
A
L
L
(S
Q
.
I
N
.
E
A
C
H
)
RI
D
G
E
V
E
N
T
(S
Q
.
I
N
.
P
E
R
L
F
)
EA
V
E
V
E
N
T
(S
Q
.
I
N
.
E
A
C
H
)
CO
N
T
.
V
E
N
T
(S
Q
.
I
N
.
P
E
R
L
F
)
61
.
0
0
40
.
0
0
18
.
0
0
28
.
0
0
10
.
0
0
P O T V E N T S O N L Y
0.5
8
0.
7
3
0.
8
5
48
.
4
1
2
0
AT
E
A
V
E
0.8
7
0.
7
3
0.
9
0
51
.
5
9
0
13
.
0
0
TO
T
A
L
(M
I
N
)
1.
4
5
1.
4
5
1.
7
5
10
0
.
0
0
RI
D
G
E
VE
N
T
0.5
8
0.
7
3
0.
6
3
42
.
8
6
0
0
5.
0
0
AT
E
A
V
E
0.8
7
0.
7
3
0.
8
3
57
.
1
4
0
12
.
0
0
TO
T
A
L
(M
I
N
)
1.
4
5
1.
4
5
1.
4
6
10
0
.
0
0
A D D I T I O N A L P O T V E N T S M A Y B E R E Q U I R E D I F T H E R E I S I N S U F F I C I E N T R I D G E A V A I L A B L E
\pxql;PROVIDE ADEQUATE OPENING FOR AIR MOVEMENT BETWEEN ATTIC SPACES TO SUPPORT REQUIRED VENTILATION
POT VENTS
\A1;1'-0"\PTYP.
\A1;16'-0"
\A1;16'-0"
\A1;10'-0"\A1;5'-0"
\A1;1'-0"\PTYP.
\A1;10'-0"
\A1;10'-0"
\A1;7'-0"
GUTTER & DOWNSPOUTS, PER SPEC (VERIFY LOCATIONS)
{\W0.7;VENTILATION REQUIRED AND SUPPLIED IS BASED ON POT VENT VALUES AND RIDGE VENT VALUES SHOWN IN TABLE ABOVE\P** CONTRACTORS INSTALLING VENTILATION ARE RESPONSIBLE FOR VERIFYING THAT VENTS USED WILL SUPPY VENTILATION TO MEET CODE REQUIREMENTS\P* SCHEDULE HAS BEEN CALCULATED ASSUMING EAVE VENTILATION AT 50-60% OF TOTAL AND RIDGE AT 40-50% OF TOTAL REQUIRED VENTILATION}
A4.01
RO
O
F
P
L
A
N
M i d w e s t Z o n e O f f i c e
1 9 0 0 G o l f R o a d - S u i t e 3 0 0
S c h a u m b u r g , I l l i n o i s 6 0 1 7 3
(c) Copyright 2015 PulteGroup, Inc.
PRODUCT MANAGERRick StarkeyVERSION RELEASEDATE:12/01/2017
PROJECT TYPESingle Family
SHEET
PLAN NAME
SPECIFICATION LEVEL
NPC CHILD NUMBER
----
Castleton
2022.300
H o m e f o r * M a r k e t H o m e *, 5 5 8 1 -0 8 1 0 0
4 4 4 5 E v e r g r e e n T r a i l , C a r m e l , I N 4 6 0 7 4
ROOF PLANSCALE: 1/4" = 1'-0" (HALF SCALE ON 11x17 PAPER)
05/30/18
William Hohlt