Loading...
HomeMy WebLinkAboutGN000.1LOT SPECIFIED PLAN INFORMATION Customer Name {\C256;* Market Home *, 5581-08100} Address{\C256;4445 EVERGREEN TRAIL}{\Fsimplex|c0;\C256;CARMEL}{\C256;IN}{\C256;46074} Community{\Fsimplex|c0;\C256;5581}{\C256;BEAR CREEK ESTATES}{\C256;5581-08100}{\C256;LOTNUM 123} Plan Features{\C256;Elevation HR2N} MUNICIPALITY STRUCTURAL ENGINEER APPLICABLE CODES MECHANICAL ENGINEER BUILDING CODE ANALYSIS DESIGN LOADS and CRITERIA AREA CALCULATION (SQ. FT.) \pxt12;{\H0.92593x;BUILDING CODE:\PPLUMBING CODE: \P\pql;MECHANICAL CODE:\PFUEL AND GAS CODE:\P\pq*;ENERGY CODE:\PELECTRICAL CODE:\P\pql;FIRE CODE:\P\pt14;\P\pq*,tz;}1. PRIOR TO THE START OF CONSTRUCTION, THE CONTRACTOR SHALL VERIFY THE REQUIRED DESIGN LOADS WITH GOVERNING CODES AND SITE CONDITIONS. VERIFY WITH THE LOCAL BUILDING AGENCIES THE WIND, SEISMIC, SNOW AND OTHER SPECIAL LOADING CONDITIONS. THE ARCHITECT SHALL BE NOTIFIED IN WRITING OF ALL DISCREPANCIES.\P\pa0.25;2. THERE SHALL BE NO STRUCTURAL CHANGES WITHOUT WRITTEN CONSENT OF THE ENGINEER OF RECORD.{\H0.92593x; } ZONING ORDINANCE: .\PUSE GROUP: .\PCONSTRUCTION CLASS: .\PHEIGHT & AREA: .\POTHER REQUIREMENTS: .\pxt20,28;LIVE LOADS:\P\pt2,r28; Sleeping ___ PSF\P Non-Sleeping ___ PSF\P Ext. Decks & Stairs ___ PSF\P\ptr28;DEAD LOAD: ___ PSF\P\pt2,r27; Guard Rail & Handrail ___ LB \P\pt2,r28; Guard Infill Components ___ PSF\P\ptr28;WIND SPEED: ___ MPH\PROOF LIVE LOAD: ___ PSF\PSNOW LOAD: ___ PSF\PLATERAL LOAD: ___ PCF \pxql;{\H1.3334x;.\P\H0.69446x;.\P.\P.\P.} \pxql;{\H1.3334x;.\P\H0.69446x;.\P.\P.\P.}\pxql;{\H1.3334x;.\P\H0.69446x;.\P.\P.\P.} SHEET LIST TABLE SHT DESCRIPTION CC.01 Cover Sheet CC.02 Notes - Schedules and Legends A0.01 Foundation - Basement A1.11 1st Floor Plan A1.21 2nd Floor Plan A2.02 Building Section A2.03 Building Section A3.01 Front Elevation A3.02 Left Elevation A3.03 Right Elevation A3.04 Rear Elevation A4.01 Roof Plan U0.01 Basement Utility Plan U1.11 1st Floor Utility Plan U1.21 2nd Floor Utility Plan Structural Plan - Foundation Basement (IN Code) Structural Plan - 1st Floor (IN Code) Structural Plan - 2nd Floor (IN Code)LOT SPECIFIC OPTION SELECTIONSOpt Cabinets at LaundryOpt Basement Bath Rough-InBuilt in Kitchen OptionDaylight Basement OptionOpt Deck at RearElevation HR2NNo OptionStandard Flex RoomBasement FoundationTraditional Fireplace at Gathering Room3 Car Side Load GarageOwner's Bath 4Additional Windows on Side ElevationsOpt Sink at LaundryIndiana SQUARE FOOTAGE TOTAL:CONDITIONED - LIVABLE SF 1st Floor 2nd Floor 1672 SF 1694 SF 3366 SF TOTAL:CONDITIONED - NON-LIVABLE SF Basement - Unfinished 1563 SF 1563 SF TOTAL:UNCONDITIONED SF 3 Car Garage Side Front Porch 674 SF 115 SF 789 SF 5717 SF CO V E R S H E E T M i d w e s t Z o n e O f f i c e 1 9 0 0 G o l f R o a d - S u i t e 3 0 0 S c h a u m b u r g , I l l i n o i s 6 0 1 7 3 (c) Copyright 2015 PulteGroup, Inc. PRODUCT MANAGERRick StarkeyVERSION RELEASEDATE:12/01/2017 PROJECT TYPESingle Family SHEET PLAN NAME SPECIFICATION LEVEL NPC CHILD NUMBER ---- Castleton 2022.300 H o m e f o r * M a r k e t H o m e *, 5 5 8 1 -0 8 1 0 0 4 4 4 5 E v e r g r e e n T r a i l , C a r m e l , I N 4 6 0 7 4 CC.01 05/30/18 William Hohlt