HomeMy WebLinkAboutA001.0SUMP w/ CHECK VALVE, VERIFY LOCATIONOPT. EJECTOR PIT AND PUMP AS REQUIRED, VERIFY LOCATIONPROVIDE SEPARATION BETWEEN WATER & SEWER LINES, PER CODE
FURNACE PER MECHANICAL PLANS WATER HEATER, PER SPECOPT. WATER SOFTENER, PER SPECRADON VENT PER CODE, VERIFY LOCATION
2A2 B.1
1A2 B.1
1A2 B.1
2A2 B.1
3A2 B.2
4A2 B.2 4A2 B.2
PERIMETER DRAIN, PER SPEC
UP 7 RISERS
HANDRAIL, PER CODE
1234567 POST & BEAM PER STRUCTURAL PLANS POST & BEAM PER STRUCTURAL PLANS
12345678
\pxql;2/8
FD
4140 SL & EGRESS WELL #4, AS REQUIRED BY CODE\PSEE STRUCTURAL DETAILS
OPT\PROUGH IN BATH
36x60 SHOWER
GAS VALVE
POST & BEAM PER STRUCTURAL PLANS
ADD RISER W/ OPT. 9'-0" POUR
\A1;22'-8{\H0.750000x;\S1#2;}"\A1;10'-7{\H0.750000x;\S1#2;}"
\A1;10'-3{\H0.750000x;\S1#2;}"\A1;3'-6{\H0.750000x;\S1#2;}"\A1;3'-6{\H0.750000x;\S1#2;}"\A1;15'-11{\H0.750000x;\S1#2;}"
\A1;10'-8"
\A1;18'-8"
\A1;18'-8"\A1;19'-5"
\A1;12'-1"
\A1;6'-5{\H0.750000x;\S1#2;}"
\A1;4'-5{\H0.750000x;\S1#4;}"
\A1;7'-0"\A1;48'-0" - OVERALL
\A1;31'-6"
\A1;16'-6"
\A1;19'-3{\H0.750000x;\S3#4;}"
\A1;12'-2{\H0.750000x;\S1#4;}"
\A1;2'-11{\H0.750000x;\S3#4;}"
\A1;5'-0"
\A1;2'-7{\H0.750000x;\S1#4;}"
\A1;20'-6{\H0.750000x;\S1#2;}"\A1;1'-5{\H0.750000x;\S1#2;}"\A1;2'-7{\H0.750000x;\S1#2;}"
\A1;42'-3{\H0.750000x;\S1#2;}"
SLAB/UNEXCAVATED
LEAD WALL PAST OVERDIG, FIELD VERIFY LOCATION\P(TYP.)
\A1;33'-4"
\A1;29'-4"
\A1;48'-0" - OVERALL
\A1;19'-9{\H0.750000x;\S1#2;}"
\A1;9'-6{\H0.750000x;\S1#2;}"
\A1;64'-3{\H0.750000x;\S1#2;}" - OVERALL \A1;30'-11{\H0.750000x;\S1#2;}"
\A1;64'-3{\H0.750000x;\S1#2;}" - OVERALL
\A1;11'-11{\H0.750000x;\S1#2;}"
\A1;1'-9"\A1;2'-6{\H0.750000x;\S1#2;}"
\A1;11'-8"
\A1;8'-3"\A1;2'-2"\A1;16'-3"
LEAD WALL PAST OVERDIG, FIELD VERIFY LOCATION\P(TYP.)
\A1;10'-8"
\A1;8'-0"
\A1;1'-9{\H0.750000x;\S1#2;}"
\A1;4'-5"
\A1;1'-9{\H0.750000x;\S1#2;}"
\A1;2'-8"\A1;1'-9{\H0.750000x;\S1#2;}"\A1;10{\H0.750000x;\S1#2;}"\A1;5'-4"\A1;1'-9{\H0.750000x;\S1#2;}"\A1;3'-6{\H0.750000x;\S1#2;}"
\A1;8'-10{\H0.750000x;\S1#2;}"
\A1;1'-9{\H0.750000x;\S1#2;}"
CO
N
C
R
E
T
E
S
L
A
B
UNEXCAVATED (SEE STRUCTURAL PLANS)
PO
R
C
H
UNEXCAVATED (SEE STRUCTURAL PLANS)
3A2 B.2
\A1;47'-0" TO CORNER
\A1;10'-6"
\A1;5'-2"
\A1;12'-6{\H0.750000x;\S1#2;}"
\A1;7'-10"
\A1;10'-10"
BA
S
E
M
E
N
T
U
N
F
I
N
I
S
H
E
D
SLAB (SEE STRUCTURAL PLANS)
HV
A
C
A0.01
FO
U
N
D
A
T
I
O
N
-
B
A
S
E
M
E
N
T
M i d w e s t Z o n e O f f i c e
1 9 0 0 G o l f R o a d - S u i t e 3 0 0
S c h a u m b u r g , I l l i n o i s 6 0 1 7 3
(c) Copyright 2017 PulteGroup, Inc.
PRODUCT MANAGERRick StarkeyVERSION RELEASEDATE:12/12/2016
PROJECT TYPESingle Family
SHEET
PLAN NAME
SPECIFICATION LEVEL
NPC CHILD NUMBER
----
Allison II
2377.300
H o m e f o r * M a r k e t H o m e *, 5 5 8 1 -0 8 5 0 0
4 4 6 1 E v e r g r e e n T r a i l , C a r m e l , I N 4 6 0 7 4
BASEMENT FOUNDATION PLANSCALE: 1/4" = 1'-0" (HALF SCALE ON 11x17 PAPER)
CR
A
W
L
S
P
A
C
E
06/11/18
Mike Sheeks