TRUSS
Re: Liu, Xuegang Pages or sheets covered by this seal: I33391274 thru I33391330 My license renewal date for the state of Indiana is July 31, 2018. B18801553 Truss Engineer's responsibility is solely for design of individual trusses based upon design parameters shown on referenced truss drawings. Parameters have not been verified as appropriate for any use. Any location identification specified is for file reference only and has not been used in preparing design. Suitability of truss designs for any particular building is the responsibility of the building designer, not the Truss Engineer, per ANSI/TPI-1, Chapter 2. IMPORTANT NOTE: CALA 17 CLAY The truss drawing(s) referenced below have been prepared by MiTek USA, Inc. under my direct supervision based on the parameters provided by ProBuild (CarterLee Bldg Components). 16023 Swingley Ridge Rd Chesterfield, MO 63017 314-434-1200 MiTek USA, Inc. May 21,2018 Job B18801553 Truss CG01 Truss Type Diagonal Hip Girder Qty 1 Ply 1 CALA 17 CLAY Job Reference (optional) I33391274 7.640 s Aug 16 2017 MiTek Industries, Inc. Sat May 19 15:22:49 2018 Page 1 Builders First Source, mooresville,in ID:mC?hxK0VUR49rWXHgogScbzvq6P-n74Xum6zQnQdFNIy6amPSo54e?JKMj7u6hkKC6zEula Scale = 1:19.0 1 2 3 4 7 6 5 8 9 2x4 3x4 2x4 2x4 3-3-2 3-2-6 -2-1-2 2-1-2 3-3-2 3-3-2 1- 1 - 6 2- 5 - 0 2- 6 - 1 4 5.37 12 LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 NO IRC2006/TPI2002 CSI. TC BC WB (Matrix) 0.41 0.06 0.00 DEFL. Vert(LL) Vert(TL) Horz(TL) in -0.00 -0.01 0.00 (loc) 6-7 6-7 6 l/defl >999 >999 n/a L/d 240 180 n/a PLATES MT20 Weight: 13 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x4 SPF-S Stud BRACING- TOP CHORD Structural wood sheathing directly applied or 3-3-2 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 6-0-0 oc bracing. REACTIONS.(lb/size) 7=302/0-6-5, 6=73/Mechanical Max Horz 7=84(LC 4) Max Uplift7=-89(LC 5), 6=-18(LC 4) Max Grav 7=302(LC 1), 6=83(LC 2) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-7=-264/110 NOTES-(8-9) 1) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; enclosed; MWFRS (low-rise) gable end zone; cantilever left and right exposed ; end vertical left and right exposed; Lumber DOL=1.60 plate grip DOL=1.60 2) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 3) Refer to girder(s) for truss to truss connections. 4) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 89 lb uplift at joint 7 and 18 lb uplift at joint 6. 5) "Semi-rigid pitchbreaks with fixed heels" Member end fixity model was used in the analysis and design of this truss. 6) Hanger(s) or other connection device(s) shall be provided sufficient to support concentrated load(s) 71 lb down and 3 lb up at 1-0-2 on top chord, and at 1-0-2 on bottom chord. The design/selection of such connection device(s) is the responsibility of others. 7) In the LOAD CASE(S) section, loads applied to the face of the truss are noted as front (F) or back (B). 8) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 9) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). LOAD CASE(S) Standard 1) Dead + Roof Live (balanced): Lumber Increase=1.15, Plate Increase=1.15 Uniform Loads (plf) Vert: 1-2=-60, 2-3=-60, 3-4=-20, 5-7=-20 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. May 21,2018 Job B18801553 Truss CG02 Truss Type Diagonal Hip Girder Qty 1 Ply 1 CALA 17 CLAY Job Reference (optional) I33391275 7.640 s Aug 16 2017 MiTek Industries, Inc. Sat May 19 15:22:50 2018 Page 1 Builders First Source, mooresville,in ID:mC?hxK0VUR49rWXHgogScbzvq6P-FJev567bB5YUsXt8gHHe_?eB_PXU5AM2KLTulYzEulZ Scale = 1:17.2 1 2 3 6 7 8 9 4 10 11 12 5 3x4 2x4 2x4 7-2-9 7-2-0 -1-8-4 1-8-4 7-0-5 7-0-5 7-2-9 0-2-4 0- 6 - 0 1- 8 - 0 1- 9 - 0 2.08 12 LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 NO IRC2006/TPI2002 CSI. TC BC WB (Matrix) 0.69 0.51 0.00 DEFL. Vert(LL) Vert(TL) Horz(TL) in -0.10 -0.31 0.00 (loc) 2-6 2-6 4 l/defl >824 >268 n/a L/d 240 180 n/a PLATES MT20 Weight: 20 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x4 SPF-S Stud BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS.(lb/size) 4=-140/Mechanical, 2=412/0-5-3, 5=450/Mechanical Max Horz 2=46(LC 4) Max Uplift4=-140(LC 1), 2=-90(LC 3), 5=-281(LC 5) Max Grav 4=349(LC 2), 2=412(LC 1), 5=450(LC 1) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 3-6=-377/347 NOTES-(8-9) 1) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; enclosed; MWFRS (low-rise) gable end zone; cantilever left and right exposed ; end vertical left and right exposed; Lumber DOL=1.60 plate grip DOL=1.60 2) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 3) Refer to girder(s) for truss to truss connections. 4) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 140 lb uplift at joint 4, 90 lb uplift at joint 2 and 281 lb uplift at joint 5. 5) "Semi-rigid pitchbreaks with fixed heels" Member end fixity model was used in the analysis and design of this truss. 6) Hanger(s) or other connection device(s) shall be provided sufficient to support concentrated load(s) 23 lb up at 3-6-6, and 11 lb up at 4-1-12, and 33 lb down and 35 lb up at 6-6-10 on top chord, and at 3-6-6, and at 4-1-12, and 40 lb down at 6-6-10 on bottom chord. The design/selection of such connection device(s) is the responsibility of others. 7) In the LOAD CASE(S) section, loads applied to the face of the truss are noted as front (F) or back (B). 8) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 9) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). LOAD CASE(S) Standard 1) Dead + Roof Live (balanced): Lumber Increase=1.15, Plate Increase=1.15 Uniform Loads (plf) Vert: 1-3=-60, 3-4=-60, 2-5=-20 Concentrated Loads (lb) Vert: 9=-33(B) 12=-20(B) 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. May 21,2018 Job B18801553 Truss CG03 Truss Type Diagonal Hip Girder Qty 1 Ply 1 CALA 17 CLAY Job Reference (optional) I33391276 7.640 s Aug 16 2017 MiTek Industries, Inc. Sat May 19 15:22:50 2018 Page 1 Builders First Source, mooresville,in ID:mC?hxK0VUR49rWXHgogScbzvq6P-FJev567bB5YUsXt8gHHe_?eFOPfZ5AM2KLTulYzEulZ Scale = 1:19.0 1 2 3 4 7 6 5 8 9 2x4 3x4 2x4 2x4 3-3-2 3-2-6 -2-1-2 2-1-2 3-2-6 3-2-6 3-3-2 0-0-12 1- 1 - 6 2- 5 - 0 2- 6 - 1 4 5.37 12 LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 NO IRC2006/TPI2002 CSI. TC BC WB (Matrix) 0.41 0.06 0.00 DEFL. Vert(LL) Vert(TL) Horz(TL) in -0.00 -0.01 0.00 (loc) 6-7 6-7 6 l/defl >999 >999 n/a L/d 240 180 n/a PLATES MT20 Weight: 13 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x4 SPF-S Stud BRACING- TOP CHORD Structural wood sheathing directly applied or 3-3-2 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 6-0-0 oc bracing. REACTIONS.(lb/size) 7=302/0-6-5, 6=73/Mechanical Max Horz 7=84(LC 4) Max Uplift7=-89(LC 5), 6=-18(LC 4) Max Grav 7=302(LC 1), 6=83(LC 2) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-7=-264/110 NOTES-(8-9) 1) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; enclosed; MWFRS (low-rise) gable end zone; cantilever left and right exposed ; end vertical left and right exposed; Lumber DOL=1.60 plate grip DOL=1.60 2) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 3) Refer to girder(s) for truss to truss connections. 4) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 89 lb uplift at joint 7 and 18 lb uplift at joint 6. 5) "Semi-rigid pitchbreaks with fixed heels" Member end fixity model was used in the analysis and design of this truss. 6) Hanger(s) or other connection device(s) shall be provided sufficient to support concentrated load(s) 71 lb down and 3 lb up at 1-0-2 on top chord, and at 1-0-2 on bottom chord. The design/selection of such connection device(s) is the responsibility of others. 7) In the LOAD CASE(S) section, loads applied to the face of the truss are noted as front (F) or back (B). 8) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 9) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). LOAD CASE(S) Standard 1) Dead + Roof Live (balanced): Lumber Increase=1.15, Plate Increase=1.15 Uniform Loads (plf) Vert: 1-2=-60, 2-3=-60, 3-4=-20, 5-7=-20 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. May 21,2018 Job B18801553 Truss GE01 Truss Type GABLE Qty 1 Ply 1 CALA 17 CLAY Job Reference (optional) I33391277 7.640 s Aug 16 2017 MiTek Industries, Inc. Sat May 19 15:22:52 2018 Page 1 Builders First Source, mooresville,in ID:9WfuBFvwEjXB7g2IW?GDqxyd85s-BimgWn9riioC6r1WniJ63QjeTDK1Z3DLofy_pQzEulX Scale = 1:76.4 Sheet Back Full Sheathing 1 Ply 1/2RyDOW8 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 43 42 41 40 39 38 37 36 35 34 33 32 31 30 29 28 27 26 25 24 23 3x4 3x4 3x4 3x4 5x6 4x6 4x6 20 - 2 - 3 26-8-0 26-8-0 9-4-0 9-4-0 17-4-0 8-0-0 26-8-0 9-4-0 27-7-4 0-11-4 1- 1 - 6 10 - 5 - 6 1- 1 - 6 10 - 5 - 6 12.00 12 Plate Offsets (X,Y)-- [8:0-4-4,0-1-12], [14:0-4-4,0-1-12], [33:0-3-0,0-3-0] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2006/TPI2002 CSI. TC BC WB (Matrix) 0.24 0.12 0.11 DEFL. Vert(LL) Vert(TL) Horz(TL) in -0.00 -0.01 0.01 (loc) 22 22 23 l/defl n/r n/r n/a L/d 180 120 n/a PLATES MT20 Weight: 216 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x4 SPF-S Stud OTHERS 2x4 SPF-S Stud *Except* 11-33,10-34,9-35,8-36,7-37,12-32,13-31,14-30,15-29: 2x4 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except end verticals, and 2-0-0 oc purlins (6-0-0 max.): 8-14. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. WEBS 1 Row at midpt 11-33, 10-34, 9-35, 8-36, 7-37, 12-32, 13-31, 14-30, 15-29 REACTIONS.All bearings 26-8-0. (lb) - Max Horz 43=-262(LC 4) Max Uplift All uplift 100 lb or less at joint(s) 33, 34, 35, 37, 38, 39, 40, 41, 32, 31, 29, 28, 27, 26, 25 except 43=-196(LC 4), 23=-159(LC 5), 42=-174(LC 5), 24=-160(LC 4) Max Grav All reactions 250 lb or less at joint(s) 43, 23, 33, 34, 35, 36, 37, 38, 39, 40, 41, 42, 32, 31, 30, 29, 28, 27, 26, 25, 24 FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 6-7=-34/263, 7-8=-38/308, 14-15=-35/308, 15-16=-31/263 NOTES-(13-14) 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Truss designed for wind loads in the plane of the truss only. For studs exposed to wind (normal to the face), see Standard Industry Gable End Details as applicable, or consult qualified building designer as per ANSI/TPI 1. 4) Provide adequate drainage to prevent water ponding. 5) All plates are 2x4 MT20 unless otherwise indicated. 6) Gable requires continuous bottom chord bearing. 7) Truss to be fully sheathed from one face or securely braced against lateral movement (i.e. diagonal web). 8) Gable studs spaced at 1-4-0 oc. 9) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 10) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 33, 34, 35, 37, 38, 39, 40, 41, 32, 31, 29, 28, 27, 26, 25 except (jt=lb) 43=196, 23=159, 42=174, 24=160. 11) "Semi-rigid pitchbreaks with fixed heels" Member end fixity model was used in the analysis and design of this truss. 12) Graphical purlin representation does not depict the size or the orientation of the purlin along the top and/or bottom chord. 13) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 14) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. May 21,2018 Job B18801553 Truss GE02 Truss Type GABLE Qty 1 Ply 1 CALA 17 CLAY Job Reference (optional) I33391278 7.640 s Aug 16 2017 MiTek Industries, Inc. Sat May 19 15:22:53 2018 Page 1 Builders First Source, mooresville,in ID:9WfuBFvwEjXB7g2IW?GDqxyd85s-fuK2k79TT0w3j_cjLPqLceGp2cgJIWHU0JiYLtzEulW Scale = 1:75.8 Sheet Front Full Sheathing 1 Ply 7/16OSB8 1 2 3 4 5 6 7 8 910 11 12 13 14 15 16 17 18 19 20 21 22 43 42 41 40 39 38 37 36 35 34 33 32 31 30 29 28 27 26 25 24 23 3x4 3x4 3x6 3x6 3x4 3x4 5x6 3- 1 0 - 2 4- 0 - 0 4-4-8 20-2 - 3 12-4-0 12-4-0 13-4-0 1-0-0 14-4-0 1-0-0 26-8-0 12-4-0 -0-11-4 0-11-4 9-4-0 9-4-0 12-4-0 3-0-0 13-4-0 1-0-0 14-4-0 1-0-0 17-4-0 3-0-0 26-8-0 9-4-0 27-7-4 0-11-4 1- 1 - 6 10 - 5 - 6 1- 1 - 6 10 - 5 - 6 12.00 12 Plate Offsets (X,Y)-- [9:0-2-8,Edge], [14:0-2-8,Edge], [33:0-3-0,0-3-0] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2006/TPI2002 CSI. TC BC WB (Matrix) 0.25 0.12 0.12 DEFL. Vert(LL) Vert(TL) Horz(TL) in -0.00 -0.01 0.01 (loc) 22 22 23 l/defl n/r n/r n/a L/d 180 120 n/a PLATES MT20 Weight: 595 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x4 SPF-S Stud OTHERS 2x4 SPF-S Stud *Except* 11-35,10-36,8-37,12-31,13-30,15-29: 2x4 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except end verticals, and 2-0-0 oc purlins (10-0-0 max.): 9-14. BOT CHORD Rigid ceiling directly applied or 6-0-0 oc bracing. WEBS 1 Row at midpt 11-35, 10-36, 8-37, 12-31, 13-30, 15-29 REACTIONS.All bearings 26-8-0. (lb) - Max Horz 43=-250(LC 4) Max Uplift All uplift 100 lb or less at joint(s) 35, 37, 38, 39, 40, 41, 31, 28, 27, 26, 25 except 43=-173(LC 4), 23=-130(LC 5), 42=-166(LC 5), 24=-143(LC 4) Max Grav All reactions 250 lb or less at joint(s) 43, 23, 36, 37, 38, 39, 40, 41, 42, 30, 29, 28, 27, 26, 25, 24, 34, 32 except 35=267(LC 11), 31=267(LC 10) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 7-8=-24/283, 8-9=-26/289, 14-15=-26/289, 15-16=-24/283 NOTES-(13-14) 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Truss designed for wind loads in the plane of the truss only. For studs exposed to wind (normal to the face), see Standard Industry Gable End Details as applicable, or consult qualified building designer as per ANSI/TPI 1. 4) Provide adequate drainage to prevent water ponding. 5) All plates are 2x4 MT20 unless otherwise indicated. 6) Gable requires continuous bottom chord bearing. 7) Truss to be fully sheathed from one face or securely braced against lateral movement (i.e. diagonal web). 8) Gable studs spaced at 1-4-0 oc. 9) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 10) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 35, 37, 38, 39, 40, 41, 31, 28, 27, 26, 25 except (jt=lb) 43=173, 23=130, 42=166, 24=143. 11) "Semi-rigid pitchbreaks with fixed heels" Member end fixity model was used in the analysis and design of this truss. 12) Graphical purlin representation does not depict the size or the orientation of the purlin along the top and/or bottom chord. 13) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 14) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. May 21,2018 Job B18801553 Truss GE03 Truss Type GABLE Qty 1 Ply 1 CALA 17 CLAY Job Reference (optional) I33391279 7.640 s Aug 16 2017 MiTek Industries, Inc. Sat May 19 15:22:54 2018 Page 1 Builders First Source, mooresville,in ID:mC?hxK0VUR49rWXHgogScbzvq6P-74tQxTA5EJ2wL8Bvv7Ma9ro0i0001yxdFyR5uJzEulV Scale = 1:61.0 Sheet Back Full Sheathing 1 Ply 1/2RyDOW8 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 34 33 32 31 30 29 28 27 26 25 24 23 22 21 20 19 4x6 3x6 3x8 3x8 14- 4 - 3 22-0-0 22-0-0 11-0-0 11-0-0 22-0-0 11-0-0 22-11-4 0-11-4 0- 6 - 8 7- 1 0 - 8 0- 6 - 8 8.00 12 Plate Offsets (X,Y)-- [1:0-3-8,Edge], [17:0-3-8,Edge] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2006/TPI2002 CSI. TC BC WB (Matrix) 0.06 0.03 0.16 DEFL. Vert(LL) Vert(TL) Horz(TL) in -0.00 -0.00 0.00 (loc) 18 18 17 l/defl n/r n/r n/a L/d 180 120 n/a PLATES MT20 Weight: 116 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 OTHERS 2x4 SPF-S Stud WEDGE Left: 2x3 SPF No.2, Right: 2x3 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS.All bearings 22-0-0. (lb) - Max Horz 1=-182(LC 4) Max Uplift All uplift 100 lb or less at joint(s) 28, 29, 30, 31, 32, 33, 34, 1, 17, 25, 24, 23, 22, 21, 20, 19 Max Grav All reactions 250 lb or less at joint(s) 27, 28, 29, 30, 31, 32, 33, 34, 1, 17, 25, 24, 23, 22, 21, 20, 19 FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES-(10-11) 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Truss designed for wind loads in the plane of the truss only. For studs exposed to wind (normal to the face), see Standard Industry Gable End Details as applicable, or consult qualified building designer as per ANSI/TPI 1. 4) All plates are 2x4 MT20 unless otherwise indicated. 5) Gable requires continuous bottom chord bearing. 6) Gable studs spaced at 1-4-0 oc. 7) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 8) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 28, 29, 30, 31, 32, 33, 34, 1, 17, 25, 24, 23, 22, 21, 20, 19. 9) "Semi-rigid pitchbreaks with fixed heels" Member end fixity model was used in the analysis and design of this truss. 10) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 11) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. May 21,2018 Job B18801553 Truss GE04 Truss Type Common Supported Gable Qty 1 Ply 1 CALA 17 CLAY Job Reference (optional) I33391280 7.640 s Aug 16 2017 MiTek Industries, Inc. Sat May 19 15:22:55 2018 Page 1 Builders First Source, mooresville,in ID:mC?hxK0VUR49rWXHgogScbzvq6P-bHRo9pBj?dAnzIm5Sqtph3L5nQ9zmM?nUcBfQlzEulU Scale = 1:62.9 6- 1 1 - 1 3 Sheet Front Cathedral 0-6-4 0-6-4 1 Ply 1/2RyDOW8 1 2 3 4 5 67 9 8 12 4x6 3x8 3x8 2x4 2x4 8x8 6x8 2x4 2x4 2x4 2x4 2x4 2x4 14-4-3 0-6-4 0-6-4 11-0-0 10-5-12 21-5-12 10-5-12 22-0-0 0-6-4 -0-11-4 0-11-4 5-6-14 5-6-14 11-0-0 5-5-2 16-5-2 5-5-2 22-0-0 5-6-14 22-11-4 0-11-4 0- 6 - 8 7- 1 0 - 8 0- 6 - 8 8.00 12 Plate Offsets (X,Y)-- [2:0-1-2,Edge], [6:0-0-9,0-2-15], [10:0-1-12,0-1-0], [11:0-0-9,0-1-12], [12:0-1-12,0-1-0] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2006/TPI2002 CSI. TC BC WB (Matrix) 0.49 0.88 0.36 DEFL. Vert(LL) Vert(TL) Horz(TL) in -0.26 -0.68 0.04 (loc) 6-9 6-9 6 l/defl >999 >384 n/a L/d 240 180 n/a PLATES MT20 Weight: 103 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x4 SPF-S Stud WEDGE Left: 2x4 SPF-S Stud, Right: 2x4 SPF-S Stud BRACING- TOP CHORD Structural wood sheathing directly applied or 4-8-15 oc purlins. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS.(lb/size) 2=936/0-3-8, 6=932/0-3-8 Max Horz 2=-177(LC 4) Max Uplift2=-71(LC 6), 6=-69(LC 7) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-3=-1180/133, 3-4=-907/120, 4-5=-907/120, 5-6=-1135/129 BOT CHORD 2-9=-65/916, 8-9=-17/931, 6-8=-17/931 WEBS 4-9=-25/638, 9-12=-333/162, 5-12=-314/161, 3-9=-319/161 NOTES-(7-8) 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) The Fabrication Tolerance at joint 6 = 16% 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 2, 6. 6) "Semi-rigid pitchbreaks with fixed heels" Member end fixity model was used in the analysis and design of this truss. 7) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 8) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. May 21,2018 Job B18801553 Truss GE05 Truss Type Monopitch Supported Gable Qty 1 Ply 1 CALA 17 CLAY Job Reference (optional) I33391281 7.640 s Aug 16 2017 MiTek Industries, Inc. Sat May 19 15:22:55 2018 Page 1 Builders First Source, mooresville,in ID:mC?hxK0VUR49rWXHgogScbzvq6P-bHRo9pBj?dAnzIm5Sqtph3L7pQJkmQAnUcBfQlzEulU Scale = 1:17.2 Sheet Front Full Sheathing 1 Ply 1/2RyDOW8 1 2 3 4 5 8 7 6 2x4 2x4 3x4 2x4 2x4 2x4 2x4 9-1-1 -0-11-4 0-11-4 7-11-8 7-11-8 0- 4 - 1 2 2- 0 - 1 0 2.50 12 LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2006/TPI2002 CSI. TC BC WB (Matrix) 0.36 0.25 0.09 DEFL. Vert(LL) Vert(TL) Horz(TL) in 0.00 0.02 0.00 (loc) 1 1 6 l/defl n/r n/r n/a L/d 180 120 n/a PLATES MT20 Weight: 23 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x4 SPF-S Stud OTHERS 2x4 SPF-S Stud BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS.All bearings 7-11-8. (lb) - Max Horz 2=57(LC 5) Max Uplift All uplift 100 lb or less at joint(s) 6, 2, 8 except 7=-118(LC 1) Max Grav All reactions 250 lb or less at joint(s) 6, 2, 7 except 8=491(LC 1) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. WEBS 3-8=-362/194 NOTES-(8-9) 1) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) Truss designed for wind loads in the plane of the truss only. For studs exposed to wind (normal to the face), see Standard Industry Gable End Details as applicable, or consult qualified building designer as per ANSI/TPI 1. 3) Gable requires continuous bottom chord bearing. 4) Gable studs spaced at 1-4-0 oc. 5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 6, 2, 8 except (jt=lb) 7=118. 7) "Semi-rigid pitchbreaks with fixed heels" Member end fixity model was used in the analysis and design of this truss. 8) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 9) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. May 21,2018 Job B18801553 Truss GE06 Truss Type GABLE Qty 1 Ply 1 CALA 17 CLAY Job Reference (optional) I33391282 7.640 s Aug 16 2017 MiTek Industries, Inc. Sat May 19 15:22:56 2018 Page 1 Builders First Source, mooresville,in ID:mC?hxK0VUR49rWXHgogScbzvq6P-3T?BM9CMmxIeaSLI0YO2EGuMCqiSVt1wjGwCyCzEulT Scale = 1:55.1 Sheet Front Full Sheathing 1 Ply 1/2RyDOW8 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 30 29 28 27 26 25 24 23 22 21 20 19 18 4x6 3x8 5x6 3x8 13-1-1 2 20-0-0 20-0-0 -0-11-4 0-11-4 10-0-0 10-0-0 20-0-0 10-0-0 20-11-4 0-11-4 0- 6 - 8 7- 2 - 8 0- 6 - 8 8.00 12 Plate Offsets (X,Y)-- [2:0-3-8,Edge], [16:0-3-8,Edge], [24:0-3-0,0-3-0] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2006/TPI2002 CSI. TC BC WB (Matrix) 0.06 0.03 0.12 DEFL. Vert(LL) Vert(TL) Horz(TL) in -0.00 -0.00 0.00 (loc) 17 17 16 l/defl n/r n/r n/a L/d 180 120 n/a PLATES MT20 Weight: 102 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 OTHERS 2x4 SPF-S Stud WEDGE Left: 2x3 SPF No.2, Right: 2x3 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS.All bearings 20-0-0. (lb) - Max Horz 2=-161(LC 4) Max Uplift All uplift 100 lb or less at joint(s) 2, 25, 26, 27, 28, 29, 30, 23, 16, 22, 21, 20, 19, 18 Max Grav All reactions 250 lb or less at joint(s) 2, 24, 25, 26, 27, 28, 29, 30, 23, 16, 22, 21, 20, 19, 18 FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES-(10-11) 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Truss designed for wind loads in the plane of the truss only. For studs exposed to wind (normal to the face), see Standard Industry Gable End Details as applicable, or consult qualified building designer as per ANSI/TPI 1. 4) All plates are 2x4 MT20 unless otherwise indicated. 5) Gable requires continuous bottom chord bearing. 6) Gable studs spaced at 1-4-0 oc. 7) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 8) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 2, 25, 26, 27, 28, 29, 30, 23, 16, 22, 21, 20, 19, 18. 9) "Semi-rigid pitchbreaks with fixed heels" Member end fixity model was used in the analysis and design of this truss. 10) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 11) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. May 21,2018 Job B18801553 Truss GE12 Truss Type GABLE Qty 1 Ply 1 CALA 17 CLAY Job Reference (optional) I33391283 7.640 s Aug 16 2017 MiTek Industries, Inc. Sat May 19 15:22:56 2018 Page 1 Builders First Source, mooresville,in ID:mC?hxK0VUR49rWXHgogScbzvq6P-3T?BM9CMmxIeaSLI0YO2EGuNGqiTVuSwjGwCyCzEulT Scale = 1:25.5 Sheet Front Full Sheathing 1 Ply 1/2RyDOW8 1 2 3 4 5 6 7 8 9 10 11 18 17 16 15 14 13 12 4x6 3x4 3x8 3x4 3x8 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 7-4-15 12-0-0 12-0-0 -0-11-4 0-11-4 6-0-0 6-0-0 12-0-0 6-0-0 12-11-4 0-11-4 0- 6 - 1 2 2- 9 - 1 2 0- 6 - 1 2 4.50 12 Plate Offsets (X,Y)-- [2:0-0-0,0-1-4], [2:0-3-0,Edge], [10:0-0-0,0-1-4], [10:0-3-0,Edge] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2006/TPI2002 CSI. TC BC WB (Matrix) 0.06 0.03 0.03 DEFL. Vert(LL) Vert(TL) Horz(TL) in -0.00 -0.00 0.00 (loc) 11 11 10 l/defl n/r n/r n/a L/d 180 120 n/a PLATES MT20 Weight: 41 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 OTHERS 2x4 SPF-S Stud WEDGE Left: 2x3 SPF No.2, Right: 2x3 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS.All bearings 12-0-0. (lb) - Max Horz 2=26(LC 6) Max Uplift All uplift 100 lb or less at joint(s) 2, 10, 16, 17, 18, 14, 13, 12 Max Grav All reactions 250 lb or less at joint(s) 2, 10, 15, 16, 17, 18, 14, 13, 12 FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES-(9-10) 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Truss designed for wind loads in the plane of the truss only. For studs exposed to wind (normal to the face), see Standard Industry Gable End Details as applicable, or consult qualified building designer as per ANSI/TPI 1. 4) Gable requires continuous bottom chord bearing. 5) Gable studs spaced at 1-4-0 oc. 6) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 2, 10, 16, 17, 18, 14, 13, 12. 8) "Semi-rigid pitchbreaks with fixed heels" Member end fixity model was used in the analysis and design of this truss. 9) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 10) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. May 21,2018 Job B18801553 Truss J01 Truss Type Jack-Closed Girder Qty 1 Ply 1 CALA 17 CLAY Job Reference (optional) I33391284 7.640 s Aug 16 2017 MiTek Industries, Inc. Sat May 19 15:22:57 2018 Page 1 Builders First Source, mooresville,in ID:mC?hxK0VUR49rWXHgogScbzvq6P-YfZZZVD_XEQVCcvUaFvHmUQRVE?QEEt4xwglUezEulS Scale = 1:19.1 1 2 3 4 5 9 8 7 6 10 11 2x4 3x4 3x4 3x4 2x4 2x4 2x4 3x8 2-0-0 2-0-0 4-6-0 2-6-0 -0-11-4 0-11-4 1-6-0 1-6-0 2-0-0 0-6-0 4-6-0 2-6-0 1- 1 - 6 2- 6 - 1 2- 7 - 6 1- 2 - 9 1- 3 - 8 1- 6 - 1 1- 0 - 0 2- 6 - 1 12.00 12 Plate Offsets (X,Y)-- [3:0-2-7,0-1-8], [6:0-3-8,Edge] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 NO IRC2006/TPI2002 CSI. TC BC WB (Matrix) 0.48 0.24 0.46 DEFL. Vert(LL) Vert(TL) Horz(TL) in 0.03 -0.05 0.04 (loc) 8 8 6 l/defl >999 >999 n/a L/d 240 180 n/a PLATES MT20 Weight: 16 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x4 SPF-S Stud BRACING- TOP CHORD Structural wood sheathing directly applied or 4-6-0 oc purlins, except end verticals, and 2-0-0 oc purlins: 3-5. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS.(lb/size) 9=327/0-3-8, 6=245/0-1-8 Max Horz 9=82(LC 5) Max Uplift9=-65(LC 5), 6=-57(LC 4) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-9=-282/81 NOTES-(12-13) 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; enclosed; MWFRS (low-rise) gable end zone; cantilever left and right exposed ; end vertical left and right exposed; Lumber DOL=1.60 plate grip DOL=1.60 3) Provide adequate drainage to prevent water ponding. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) Bearing at joint(s) 6 considers parallel to grain value using ANSI/TPI 1 angle to grain formula. Building designer should verify capacity of bearing surface. 6) Provide mechanical connection (by others) of truss to bearing plate at joint(s) 6. 7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 9, 6. 8) "Semi-rigid pitchbreaks with fixed heels" Member end fixity model was used in the analysis and design of this truss. 9) Graphical purlin representation does not depict the size or the orientation of the purlin along the top and/or bottom chord. 10) Hanger(s) or other connection device(s) shall be provided sufficient to support concentrated load(s) 51 lb down and 32 lb up at 1-6-0, and 119 lb down and 32 lb up at 2-6-12 on bottom chord. The design/selection of such connection device(s) is the responsibility of others. 11) In the LOAD CASE(S) section, loads applied to the face of the truss are noted as front (F) or back (B). 12) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 13) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). LOAD CASE(S) Standard 1) Dead + Roof Live (balanced): Lumber Increase=1.15, Plate Increase=1.15 Uniform Loads (plf) Vert: 1-2=-60, 2-3=-60, 3-5=-60, 8-9=-20, 6-7=-20 Concentrated Loads (lb) Vert: 10=-51(B) 11=-119(B) 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. May 21,2018 Job B18801553 Truss J02 Truss Type Jack-Closed Qty 1 Ply 1 CALA 17 CLAY Job Reference (optional) I33391285 7.640 s Aug 16 2017 MiTek Industries, Inc. Sat May 19 15:22:57 2018 Page 1 Builders First Source, mooresville,in ID:mC?hxK0VUR49rWXHgogScbzvq6P-YfZZZVD_XEQVCcvUaFvHmUQTnE1DEJR4xwglUezEulS Scale = 1:25.2 1 2 3 4 5 9 8 7 6 2x4 3x4 3x4 3x4 2x4 2x4 2x4 3x6 2-0-0 2-0-0 4-6-0 2-6-0 -0-11-4 0-11-4 2-0-0 2-0-0 2-6-0 0-6-0 4-6-0 2-0-0 1- 1 - 6 3- 5 - 1 1 3- 7 - 6 2- 2 - 3 1- 3 - 8 2- 5 - 1 1 1- 0 - 0 3- 5 - 1 1 12.00 12 Plate Offsets (X,Y)-- [4:0-2-3,0-1-8], [6:Edge,0-2-0] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2006/TPI2002 CSI. TC BC WB (Matrix) 0.33 0.12 0.17 DEFL. Vert(LL) Vert(TL) Horz(TL) in 0.03 -0.04 0.03 (loc) 8 8 6 l/defl >999 >999 n/a L/d 240 180 n/a PLATES MT20 Weight: 18 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x4 SPF-S Stud BRACING- TOP CHORD Structural wood sheathing directly applied or 4-6-0 oc purlins, except end verticals, and 2-0-0 oc purlins: 4-5. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS.(lb/size) 9=242/0-3-8, 6=160/0-1-8 Max Horz 9=97(LC 6) Max Uplift9=-26(LC 6), 6=-41(LC 5) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES-(10-11) 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Provide adequate drainage to prevent water ponding. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) Bearing at joint(s) 6 considers parallel to grain value using ANSI/TPI 1 angle to grain formula. Building designer should verify capacity of bearing surface. 6) Provide mechanical connection (by others) of truss to bearing plate at joint(s) 6. 7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 9, 6. 8) "Semi-rigid pitchbreaks with fixed heels" Member end fixity model was used in the analysis and design of this truss. 9) Graphical purlin representation does not depict the size or the orientation of the purlin along the top and/or bottom chord. 10) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 11) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. May 21,2018 Job B18801553 Truss J03 Truss Type Jack-Closed Qty 1 Ply 1 CALA 17 CLAY Job Reference (optional) I33391286 7.640 s Aug 16 2017 MiTek Industries, Inc. Sat May 19 15:22:57 2018 Page 1 Builders First Source, mooresville,in ID:mC?hxK0VUR49rWXHgogScbzvq6P-YfZZZVD_XEQVCcvUaFvHmUQTtE1UEJ34xwglUezEulS Scale = 1:31.4 1 2 3 4 5 9 8 7 6 2x4 3x4 3x4 3x4 2x4 2x4 2x4 3x6 2-0-0 2-0-0 4-6-0 2-6-0 -0-11-4 0-11-4 2-0-0 2-0-0 3-6-0 1-6-0 4-6-0 1-0-0 1- 1 - 6 4- 5 - 1 1 4- 7 - 6 3- 2 - 3 1- 3 - 8 3- 5 - 1 1 1- 0 - 0 4- 5 - 1 1 12.00 12 Plate Offsets (X,Y)-- [4:0-2-3,0-1-8], [6:Edge,0-2-0] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2006/TPI2002 CSI. TC BC WB (Matrix) 0.33 0.11 0.13 DEFL. Vert(LL) Vert(TL) Horz(TL) in 0.04 -0.06 0.04 (loc) 8 8 6 l/defl >999 >864 n/a L/d 240 180 n/a PLATES MT20 Weight: 19 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x4 SPF-S Stud BRACING- TOP CHORD Structural wood sheathing directly applied or 4-6-0 oc purlins, except end verticals, and 2-0-0 oc purlins: 4-5. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS.(lb/size) 9=242/0-3-8, 6=160/0-1-8 Max Horz 9=126(LC 5) Max Uplift9=-15(LC 6), 6=-59(LC 5) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES-(10-11) 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Provide adequate drainage to prevent water ponding. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) Bearing at joint(s) 6 considers parallel to grain value using ANSI/TPI 1 angle to grain formula. Building designer should verify capacity of bearing surface. 6) Provide mechanical connection (by others) of truss to bearing plate at joint(s) 6. 7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 9, 6. 8) "Semi-rigid pitchbreaks with fixed heels" Member end fixity model was used in the analysis and design of this truss. 9) Graphical purlin representation does not depict the size or the orientation of the purlin along the top and/or bottom chord. 10) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 11) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. May 21,2018 Job B18801553 Truss J04 Truss Type Jack-Closed Qty 7 Ply 1 CALA 17 CLAY Job Reference (optional) I33391287 7.640 s Aug 16 2017 MiTek Industries, Inc. Sat May 19 15:22:58 2018 Page 1 Builders First Source, mooresville,in ID:mC?hxK0VUR49rWXHgogScbzvq6P-0s7xnrDcIYYMqmUg8zQWJhzfTdMwzoLDAaPJ14zEulR Scale = 1:37.5 1 2 3 5 4 3x4 3x4 3x4 2x4 4-6-0 4-6-0 -0-11-4 0-11-4 4-6-0 4-6-0 1- 1 - 6 5- 7 - 6 5- 3 - 1 4 0- 3 - 8 5- 7 - 6 12.00 12 LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2006/TPI2002 CSI. TC BC WB (Matrix) 0.27 0.16 0.00 DEFL. Vert(LL) Vert(TL) Horz(TL) in 0.02 -0.04 0.00 (loc) 4-5 4-5 4 l/defl >999 >999 n/a L/d 240 180 n/a PLATES MT20 Weight: 20 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x4 SPF-S Stud BRACING- TOP CHORD Structural wood sheathing directly applied or 4-6-0 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS.(lb/size) 5=242/0-3-8, 4=160/0-1-8 Max Horz 5=167(LC 5) Max Uplift5=-12(LC 4), 4=-81(LC 5) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES-(7-8) 1) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 3) Bearing at joint(s) 4 considers parallel to grain value using ANSI/TPI 1 angle to grain formula. Building designer should verify capacity of bearing surface. 4) Provide mechanical connection (by others) of truss to bearing plate at joint(s) 4. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 5, 4. 6) "Semi-rigid pitchbreaks with fixed heels" Member end fixity model was used in the analysis and design of this truss. 7) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 8) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. May 21,2018 Job B18801553 Truss J05 Truss Type Jack-Closed Girder Qty 1 Ply 1 CALA 17 CLAY Job Reference (optional) I33391288 7.640 s Aug 16 2017 MiTek Industries, Inc. Sat May 19 15:22:58 2018 Page 1 Builders First Source, mooresville,in ID:mC?hxK0VUR49rWXHgogScbzvq6P-0s7xnrDcIYYMqmUg8zQWJhze8dKAzoLDAaPJ14zEulR Scale = 1:19.1 1 2 3 4 6 57 8 2x4 3x4 3x4 3x4 3x8 1-6-0 1-6-0 4-6-0 3-0-0 -0-11-4 0-11-4 1-6-0 1-6-0 4-6-0 3-0-0 1- 1 - 6 2- 6 - 1 2- 7 - 6 2- 2 - 9 0- 3 - 8 2- 6 - 1 12.00 12 Plate Offsets (X,Y)-- [3:0-2-7,0-1-8], [5:0-3-8,Edge] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 NO IRC2006/TPI2002 CSI. TC BC WB (Matrix) 0.36 0.27 0.00 DEFL. Vert(LL) Vert(TL) Horz(TL) in 0.03 -0.06 0.00 (loc) 5-6 5-6 5 l/defl >999 >830 n/a L/d 240 180 n/a PLATES MT20 Weight: 15 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x4 SPF-S Stud BRACING- TOP CHORD Structural wood sheathing directly applied or 4-6-0 oc purlins, except end verticals, and 2-0-0 oc purlins: 3-4. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS.(lb/size) 6=327/0-3-8, 5=245/0-1-8 Max Horz 6=80(LC 4) Max Uplift6=-66(LC 5), 5=-57(LC 4) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES-(12-13) 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; enclosed; MWFRS (low-rise) gable end zone; cantilever left and right exposed ; end vertical left and right exposed; Lumber DOL=1.60 plate grip DOL=1.60 3) Provide adequate drainage to prevent water ponding. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) Bearing at joint(s) 5 considers parallel to grain value using ANSI/TPI 1 angle to grain formula. Building designer should verify capacity of bearing surface. 6) Provide mechanical connection (by others) of truss to bearing plate at joint(s) 5. 7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 6, 5. 8) "Semi-rigid pitchbreaks with fixed heels" Member end fixity model was used in the analysis and design of this truss. 9) Graphical purlin representation does not depict the size or the orientation of the purlin along the top and/or bottom chord. 10) Hanger(s) or other connection device(s) shall be provided sufficient to support concentrated load(s) 51 lb down and 32 lb up at 1-6-0, and 119 lb down and 30 lb up at 2-6-12 on bottom chord. The design/selection of such connection device(s) is the responsibility of others. 11) In the LOAD CASE(S) section, loads applied to the face of the truss are noted as front (F) or back (B). 12) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 13) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). LOAD CASE(S) Standard 1) Dead + Roof Live (balanced): Lumber Increase=1.15, Plate Increase=1.15 Uniform Loads (plf) Vert: 1-2=-60, 2-3=-60, 3-4=-60, 5-6=-20 Concentrated Loads (lb) Vert: 7=-51(F) 8=-119(F) 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. May 21,2018 Job B18801553 Truss J06 Truss Type Jack-Open Qty 1 Ply 1 CALA 17 CLAY Job Reference (optional) I33391289 7.640 s Aug 16 2017 MiTek Industries, Inc. Sat May 19 15:22:58 2018 Page 1 Builders First Source, mooresville,in ID:mC?hxK0VUR49rWXHgogScbzvq6P-0s7xnrDcIYYMqmUg8zQWJhziRdOlzoLDAaPJ14zEulR Scale = 1:13.5 1 2 3 4 3x8 2-1-5 2-1-5 -0-11-4 0-11-4 2-1-5 2-1-5 0- 7 - 6 1- 8 - 1 1- 3 - 6 1- 8 - 1 6.00 12 Plate Offsets (X,Y)-- [2:0-3-8,Edge] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2006/TPI2002 CSI. TC BC WB (Matrix) 0.08 0.04 0.00 DEFL. Vert(LL) Vert(TL) Horz(TL) in -0.00 -0.00 -0.00 (loc) 2 2-4 3 l/defl >999 >999 n/a L/d 240 180 n/a PLATES MT20 Weight: 7 lb FT = 20% GRIP 197/144 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEDGE Left: 2x3 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 2-1-5 oc purlins. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS.(lb/size) 3=39/Mechanical, 2=160/0-3-8, 4=19/Mechanical Max Horz 2=48(LC 6) Max Uplift3=-22(LC 6), 2=-36(LC 6) Max Grav 3=39(LC 1), 2=160(LC 1), 4=38(LC 2) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES-(6-7) 1) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 3) Refer to girder(s) for truss to truss connections. 4) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 3, 2. 5) "Semi-rigid pitchbreaks with fixed heels" Member end fixity model was used in the analysis and design of this truss. 6) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 7) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. May 21,2018 Job B18801553 Truss J07 Truss Type Jack-Closed Qty 1 Ply 1 CALA 17 CLAY Job Reference (optional) I33391290 7.640 s Aug 16 2017 MiTek Industries, Inc. Sat May 19 15:22:59 2018 Page 1 Builders First Source, mooresville,in ID:mC?hxK0VUR49rWXHgogScbzvq6P-U2hJ_BEE3sgDRv3thgxlsvWfL1eIiFbMPE9sZWzEulQ Scale = 1:17.5 1 2 3 4 2x4 3x4 2x4 8-0-0 8-0-0 -0-11-4 0-11-4 8-0-0 8-0-0 0- 4 - 1 2 2- 0 - 1 2 1- 9 - 4 0- 3 - 8 2- 0 - 1 2 2.50 12 Plate Offsets (X,Y)-- [2:0-1-5,Edge] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2006/TPI2002 CSI. TC BC WB (Matrix) 0.97 0.40 0.00 DEFL. Vert(LL) Vert(TL) Horz(TL) in -0.16 -0.41 0.00 (loc) 2-4 2-4 4 l/defl >562 >225 n/a L/d 240 180 n/a PLATES MT20 Weight: 21 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF 2100F 1.8E WEBS 2x4 SPF-S Stud BRACING- TOP CHORD Structural wood sheathing directly applied, except end verticals. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS.(lb/size) 2=378/0-3-8, 4=304/0-1-8 Max Horz 2=57(LC 5) Max Uplift2=-60(LC 4), 4=-27(LC 6) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES-(7-8) 1) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 3) Bearing at joint(s) 4 considers parallel to grain value using ANSI/TPI 1 angle to grain formula. Building designer should verify capacity of bearing surface. 4) Provide mechanical connection (by others) of truss to bearing plate at joint(s) 4. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 2, 4. 6) "Semi-rigid pitchbreaks with fixed heels" Member end fixity model was used in the analysis and design of this truss. 7) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 8) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. May 21,2018 Job B18801553 Truss J08 Truss Type Jack-Open Qty 1 Ply 1 CALA 17 CLAY Job Reference (optional) I33391291 7.640 s Aug 16 2017 MiTek Industries, Inc. Sat May 19 15:22:59 2018 Page 1 Builders First Source, mooresville,in ID:mC?hxK0VUR49rWXHgogScbzvq6P-U2hJ_BEE3sgDRv3thgxlsvWs21jgiFbMPE9sZWzEulQ Scale = 1:10.1 1 2 3 4 3x4 3-6-14 3-6-14 -0-11-4 0-11-4 3-6-14 3-6-14 0- 4 - 1 2 1- 1 - 1 1 0- 9 - 1 3 1- 1 - 1 1 2.50 12 Plate Offsets (X,Y)-- [2:0-1-5,Edge] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2006/TPI2002 CSI. TC BC WB (Matrix) 0.15 0.12 0.00 DEFL. Vert(LL) Vert(TL) Horz(TL) in -0.01 -0.02 -0.00 (loc) 2-4 2-4 3 l/defl >999 >999 n/a L/d 240 180 n/a PLATES MT20 Weight: 9 lb FT = 20% GRIP 197/144 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 3-6-14 oc purlins. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS.(lb/size) 3=91/Mechanical, 2=210/0-3-8, 4=34/Mechanical Max Horz 2=30(LC 4) Max Uplift3=-29(LC 4), 2=-48(LC 4) Max Grav 3=91(LC 1), 2=210(LC 1), 4=67(LC 2) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES-(6-7) 1) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 3) Refer to girder(s) for truss to truss connections. 4) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 3, 2. 5) "Semi-rigid pitchbreaks with fixed heels" Member end fixity model was used in the analysis and design of this truss. 6) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 7) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. May 21,2018 Job B18801553 Truss J09 Truss Type Jack-Open Qty 1 Ply 1 CALA 17 CLAY Job Reference (optional) I33391292 7.640 s Aug 16 2017 MiTek Industries, Inc. Sat May 19 15:22:59 2018 Page 1 Builders First Source, mooresville,in ID:mC?hxK0VUR49rWXHgogScbzvq6P-U2hJ_BEE3sgDRv3thgxlsvWsE1jqiFbMPE9sZWzEulQ Scale = 1:13.2 1 2 3 5 42x4 3x6 2x4 3-8-2 3-8-2 -0-11-4 0-11-4 3-8-2 3-8-2 0- 6 - 0 1- 6 - 3 1- 7 - 1 2 1- 3 - 1 0 1- 7 - 1 2 3.75 12 LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2006/TPI2002 CSI. TC BC WB (Matrix) 0.14 0.11 0.00 DEFL. Vert(LL) Vert(TL) Horz(TL) in -0.01 -0.02 -0.00 (loc) 2-5 2-5 3 l/defl >999 >999 n/a L/d 240 180 n/a PLATES MT20 Weight: 11 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x4 SPF-S Stud BRACING- TOP CHORD Structural wood sheathing directly applied or 3-8-2 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS.(lb/size) 2=206/0-3-8, 3=87/Mechanical, 5=38/Mechanical Max Horz 2=63(LC 6) Max Uplift2=-46(LC 4), 3=-36(LC 6) Max Grav 2=206(LC 1), 3=87(LC 1), 5=76(LC 2) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES-(7-8) 1) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 3) Refer to girder(s) for truss to truss connections. 4) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 2, 3. 5) "Semi-rigid pitchbreaks with fixed heels" Member end fixity model was used in the analysis and design of this truss. 6) Gap between inside of top chord bearing and first diagonal or vertical web shall not exceed 0.500in. 7) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 8) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. May 21,2018 Job B18801553 Truss J10 Truss Type Jack-Open Qty 1 Ply 1 CALA 17 CLAY Job Reference (optional) I33391293 7.640 s Aug 16 2017 MiTek Industries, Inc. Sat May 19 15:23:00 2018 Page 1 Builders First Source, mooresville,in ID:mC?hxK0VUR49rWXHgogScbzvq6P-yEFhCWFsq9o333e3FOS_O622xR43RirWduuQ5zzEulP Scale = 1:10.8 1 2 3 4 2x4 2-4-2 2-4-2 -0-11-4 0-11-4 2-4-2 2-4-2 0- 6 - 0 1- 2 - 1 2 0- 1 0 - 1 0 1- 2 - 1 2 3.75 12 LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2006/TPI2002 CSI. TC BC WB (Matrix) 0.08 0.05 0.00 DEFL. Vert(LL) Vert(TL) Horz(TL) in -0.00 -0.00 -0.00 (loc) 2-4 2-4 3 l/defl >999 >999 n/a L/d 240 180 n/a PLATES MT20 Weight: 7 lb FT = 20% GRIP 197/144 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 2-4-2 oc purlins. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS.(lb/size) 3=47/Mechanical, 2=167/0-3-8, 4=21/Mechanical Max Horz 2=32(LC 4) Max Uplift3=-17(LC 4), 2=-44(LC 4) Max Grav 3=47(LC 1), 2=167(LC 1), 4=43(LC 2) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES-(6-7) 1) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 3) Refer to girder(s) for truss to truss connections. 4) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 3, 2. 5) "Semi-rigid pitchbreaks with fixed heels" Member end fixity model was used in the analysis and design of this truss. 6) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 7) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. May 21,2018 Job B18801553 Truss J11 Truss Type Jack-Open Qty 1 Ply 1 CALA 17 CLAY Job Reference (optional) I33391294 7.640 s Aug 16 2017 MiTek Industries, Inc. Sat May 19 15:23:00 2018 Page 1 Builders First Source, mooresville,in ID:mC?hxK0VUR49rWXHgogScbzvq6P-yEFhCWFsq9o333e3FOS_O622wR4DRirWduuQ5zzEulP Scale = 1:13.5 1 2 3 4 3x8 2-1-5 2-1-5 -0-11-4 0-11-4 2-1-5 2-1-5 0- 7 - 6 1- 8 - 1 1- 3 - 6 1- 8 - 1 6.00 12 Plate Offsets (X,Y)-- [2:0-3-8,Edge] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2006/TPI2002 CSI. TC BC WB (Matrix) 0.08 0.04 0.00 DEFL. Vert(LL) Vert(TL) Horz(TL) in -0.00 -0.00 -0.00 (loc) 2 2-4 3 l/defl >999 >999 n/a L/d 240 180 n/a PLATES MT20 Weight: 7 lb FT = 20% GRIP 197/144 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEDGE Left: 2x3 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 2-1-5 oc purlins. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS.(lb/size) 3=39/Mechanical, 2=160/0-3-8, 4=19/Mechanical Max Horz 2=48(LC 6) Max Uplift3=-22(LC 6), 2=-36(LC 6) Max Grav 3=39(LC 1), 2=160(LC 1), 4=38(LC 2) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES-(6-7) 1) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 3) Refer to girder(s) for truss to truss connections. 4) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 3, 2. 5) "Semi-rigid pitchbreaks with fixed heels" Member end fixity model was used in the analysis and design of this truss. 6) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 7) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. May 21,2018 Job B18801553 Truss J12 Truss Type Jack-Closed Qty 1 Ply 1 CALA 17 CLAY Job Reference (optional) I33391295 7.640 s Aug 16 2017 MiTek Industries, Inc. Sat May 19 15:23:00 2018 Page 1 Builders First Source, mooresville,in ID:mC?hxK0VUR49rWXHgogScbzvq6P-yEFhCWFsq9o333e3FOS_O62?nR3ERirWduuQ5zzEulP Scale = 1:25.2 1 2 3 4 6 5 2x4 3x4 3x4 3x4 2x4 2-6-0 2-6-0 4-6-0 2-0-0 -0-11-4 0-11-4 2-6-0 2-6-0 4-6-0 2-0-0 1- 1 - 6 3- 5 - 1 1 3- 7 - 6 3- 2 - 3 0- 3 - 8 3- 5 - 1 1 12.00 12 Plate Offsets (X,Y)-- [3:0-2-3,0-1-8] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2006/TPI2002 CSI. TC BC WB (Matrix) 0.28 0.10 0.00 DEFL. Vert(LL) Vert(TL) Horz(TL) in -0.01 -0.03 0.00 (loc) 5-6 5-6 5 l/defl >999 >999 n/a L/d 240 180 n/a PLATES MT20 Weight: 17 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x4 SPF-S Stud BRACING- TOP CHORD Structural wood sheathing directly applied or 4-6-0 oc purlins, except end verticals, and 2-0-0 oc purlins: 3-4. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS.(lb/size) 6=242/0-3-8, 5=160/0-1-8 Max Horz 6=109(LC 5) Max Uplift6=-28(LC 6), 5=-43(LC 5) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES-(10-11) 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Provide adequate drainage to prevent water ponding. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) Bearing at joint(s) 5 considers parallel to grain value using ANSI/TPI 1 angle to grain formula. Building designer should verify capacity of bearing surface. 6) Provide mechanical connection (by others) of truss to bearing plate at joint(s) 5. 7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 6, 5. 8) "Semi-rigid pitchbreaks with fixed heels" Member end fixity model was used in the analysis and design of this truss. 9) Graphical purlin representation does not depict the size or the orientation of the purlin along the top and/or bottom chord. 10) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 11) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. May 21,2018 Job B18801553 Truss J13 Truss Type Jack-Closed Qty 1 Ply 1 CALA 17 CLAY Job Reference (optional) I33391296 7.640 s Aug 16 2017 MiTek Industries, Inc. Sat May 19 15:23:00 2018 Page 1 Builders First Source, mooresville,in ID:mC?hxK0VUR49rWXHgogScbzvq6P-yEFhCWFsq9o333e3FOS_O62?9R2VRirWduuQ5zzEulP Scale = 1:31.4 1 2 3 4 6 53x4 3x4 3x4 2x4 2x4 2-3-0 2-3-0 4-6-0 2-3-0 -0-11-4 0-11-4 3-6-0 3-6-0 4-6-0 1-0-0 1- 1 - 6 4- 5 - 1 1 4- 7 - 6 4- 2 - 3 0- 3 - 8 4- 5 - 1 1 12.00 12 Plate Offsets (X,Y)-- [3:0-2-3,0-1-8] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2006/TPI2002 CSI. TC BC WB (Matrix) 0.26 0.15 0.00 DEFL. Vert(LL) Vert(TL) Horz(TL) in -0.01 -0.03 0.00 (loc) 5-6 5-6 5 l/defl >999 >999 n/a L/d 240 180 n/a PLATES MT20 Weight: 18 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x4 SPF-S Stud BRACING- TOP CHORD Structural wood sheathing directly applied or 4-6-0 oc purlins, except end verticals, and 2-0-0 oc purlins: 3-4. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS.(lb/size) 6=242/0-3-8, 5=160/0-1-8 Max Horz 6=139(LC 5) Max Uplift6=-17(LC 6), 5=-60(LC 5) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES-(10-11) 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Provide adequate drainage to prevent water ponding. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) Bearing at joint(s) 5 considers parallel to grain value using ANSI/TPI 1 angle to grain formula. Building designer should verify capacity of bearing surface. 6) Provide mechanical connection (by others) of truss to bearing plate at joint(s) 5. 7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 6, 5. 8) "Semi-rigid pitchbreaks with fixed heels" Member end fixity model was used in the analysis and design of this truss. 9) Graphical purlin representation does not depict the size or the orientation of the purlin along the top and/or bottom chord. 10) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 11) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. May 21,2018 Job B18801553 Truss J14 Truss Type Jack-Closed Qty 2 Ply 1 CALA 17 CLAY Job Reference (optional) I33391297 7.640 s Aug 16 2017 MiTek Industries, Inc. Sat May 19 15:23:01 2018 Page 1 Builders First Source, mooresville,in ID:mC?hxK0VUR49rWXHgogScbzvq6P-QQo4PsGUbTwwhDDFp5_DxKbAfrOPA6_fsYezdPzEulO Scale = 1:37.5 1 2 3 4 8 7 6 5 3x4 3x4 3x4 2x4 2x4 2x4 2x4 2-0-0 2-0-0 4-6-0 2-6-0 -0-11-4 0-11-4 2-0-0 2-0-0 4-6-0 2-6-0 1- 1 - 6 5- 7 - 6 4- 3 - 1 4 1- 3 - 8 4- 7 - 6 1- 0 - 0 12.00 12 LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2006/TPI2002 CSI. TC BC WB (Matrix) 0.27 0.11 0.14 DEFL. Vert(LL) Vert(TL) Horz(TL) in 0.07 -0.08 -0.05 (loc) 7 7 5 l/defl >731 >658 n/a L/d 240 180 n/a PLATES MT20 Weight: 21 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x4 SPF-S Stud BRACING- TOP CHORD Structural wood sheathing directly applied or 4-6-0 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS.(lb/size) 8=242/0-3-8, 5=160/0-1-8 Max Horz 8=155(LC 5) Max Uplift8=-9(LC 4), 5=-80(LC 5) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES-(7-8) 1) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 3) Bearing at joint(s) 5 considers parallel to grain value using ANSI/TPI 1 angle to grain formula. Building designer should verify capacity of bearing surface. 4) Provide mechanical connection (by others) of truss to bearing plate at joint(s) 5. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 8, 5. 6) "Semi-rigid pitchbreaks with fixed heels" Member end fixity model was used in the analysis and design of this truss. 7) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 8) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. May 21,2018 Job B18801553 Truss J15 Truss Type Jack-Closed Qty 1 Ply 1 CALA 17 CLAY Job Reference (optional) I33391298 7.640 s Aug 16 2017 MiTek Industries, Inc. Sat May 19 15:23:01 2018 Page 1 Builders First Source, mooresville,in ID:mC?hxK0VUR49rWXHgogScbzvq6P-QQo4PsGUbTwwhDDFp5_DxKbB7rNJA8lfsYezdPzEulO Scale = 1:19.2 1 2 3 4 6 5 2x4 2x4 3x8 2x4 3x12 2-0-0 2-0-0 4-0-0 2-0-0 -0-11-4 0-11-4 2-0-0 2-0-0 4-0-0 2-0-0 0- 7 - 6 2- 7 - 6 1- 7 - 6 1- 0 - 0 6.00 12 Plate Offsets (X,Y)-- [2:0-3-8,Edge], [3:0-6-0,0-2-1] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2006/TPI2002 CSI. TC BC WB (Matrix) 0.24 0.18 0.02 DEFL. Vert(LL) Vert(TL) Horz(TL) in -0.01 -0.03 0.03 (loc) 6 6 5 l/defl >999 >999 n/a L/d 240 180 n/a PLATES MT20 Weight: 13 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x4 SPF-S Stud WEDGE Left: 2x3 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 4-0-0 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS.(lb/size) 5=139/Mechanical, 2=223/0-3-8 Max Horz 2=60(LC 5) Max Uplift5=-20(LC 6), 2=-39(LC 6) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES-(6-7) 1) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 3) Refer to girder(s) for truss to truss connections. 4) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 5, 2. 5) "Semi-rigid pitchbreaks with fixed heels" Member end fixity model was used in the analysis and design of this truss. 6) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 7) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. May 21,2018 Job B18801553 Truss J16 Truss Type Jack-Closed Qty 1 Ply 1 CALA 17 CLAY Job Reference (optional) I33391299 7.640 s Aug 16 2017 MiTek Industries, Inc. Sat May 19 15:23:01 2018 Page 1 Builders First Source, mooresville,in ID:mC?hxK0VUR49rWXHgogScbzvq6P-QQo4PsGUbTwwhDDFp5_DxKbBvrNdA85fsYezdPzEulO Scale = 1:19.2 1 2 3 4 2x4 2x4 3x8 4-0-0 4-0-0 -0-11-4 0-11-4 4-0-0 4-0-0 0- 7 - 6 2- 7 - 6 6.00 12 Plate Offsets (X,Y)-- [2:0-3-8,Edge] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2006/TPI2002 CSI. TC BC WB (Matrix) 0.19 0.16 0.00 DEFL. Vert(LL) Vert(TL) Horz(TL) in -0.01 -0.03 0.00 (loc) 2-4 2-4 4 l/defl >999 >999 n/a L/d 240 180 n/a PLATES MT20 Weight: 13 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x4 SPF-S Stud WEDGE Left: 2x3 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 4-0-0 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS.(lb/size) 4=139/Mechanical, 2=223/0-3-8 Max Horz 2=73(LC 5) Max Uplift4=-18(LC 6), 2=-41(LC 6) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES-(6-7) 1) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 3) Refer to girder(s) for truss to truss connections. 4) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 4, 2. 5) "Semi-rigid pitchbreaks with fixed heels" Member end fixity model was used in the analysis and design of this truss. 6) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 7) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. May 21,2018 Job B18801553 Truss J17 Truss Type Jack-Closed Qty 7 Ply 1 CALA 17 CLAY Job Reference (optional) I33391300 7.640 s Aug 16 2017 MiTek Industries, Inc. Sat May 19 15:23:02 2018 Page 1 Builders First Source, mooresville,in ID:mC?hxK0VUR49rWXHgogScbzvq6P-udMSdCG6Mn2nINoRNoVSTX8FmFfwvbLp5CNWArzEulN Scale = 1:16.6 1 2 33x4 2x4 2x4 7-11-8 7-11-8 0- 4 - 1 2 2- 0 - 1 0 1- 9 - 2 0- 3 - 8 2- 0 - 1 0 2.50 12 Plate Offsets (X,Y)-- [1:0-1-5,Edge] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2006/TPI2002 CSI. TC BC WB (Matrix) 0.64 0.41 0.00 DEFL. Vert(LL) Vert(TL) Horz(TL) in -0.17 -0.42 0.00 (loc) 1-3 1-3 3 l/defl >553 >221 n/a L/d 240 180 n/a PLATES MT20 Weight: 20 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF 2100F 1.8E BOT CHORD 2x4 SPF 2100F 1.8E WEBS 2x4 SPF-S Stud BRACING- TOP CHORD Structural wood sheathing directly applied or 7-11-8 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS.(lb/size) 1=310/Mechanical, 3=310/0-1-8 Max Horz 1=55(LC 5) Max Uplift1=-24(LC 4), 3=-30(LC 6) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES-(8-9) 1) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 3) Refer to girder(s) for truss to truss connections. 4) Bearing at joint(s) 3 considers parallel to grain value using ANSI/TPI 1 angle to grain formula. Building designer should verify capacity of bearing surface. 5) Provide mechanical connection (by others) of truss to bearing plate at joint(s) 3. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 1, 3. 7) "Semi-rigid pitchbreaks with fixed heels" Member end fixity model was used in the analysis and design of this truss. 8) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 9) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. May 21,2018 Job B18801553 Truss M01 Truss Type Monopitch Qty 6 Ply 1 CALA 17 CLAY Job Reference (optional) I33391301 7.640 s Aug 16 2017 MiTek Industries, Inc. Sat May 19 15:23:02 2018 Page 1 Builders First Source, mooresville,in ID:mC?hxK0VUR49rWXHgogScbzvq6P-udMSdCG6Mn2nINoRNoVSTX8AlFf3vbLp5CNWArzEulN Scale = 1:17.4 1 2 3 4 2x4 3x4 2x4 -0-11-4 0-11-4 7-11-8 7-11-8 0- 4 - 1 2 2- 0 - 1 0 1- 9 - 2 0- 3 - 8 2- 0 - 1 0 2.50 12 Plate Offsets (X,Y)-- [2:0-1-5,Edge] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2006/TPI2002 CSI. TC BC WB (Matrix) 0.96 0.40 0.00 DEFL. Vert(LL) Vert(TL) Horz(TL) in -0.16 -0.40 0.00 (loc) 2-4 2-4 4 l/defl >571 >228 n/a L/d 240 180 n/a PLATES MT20 Weight: 21 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF 2100F 1.8E WEBS 2x4 SPF-S Stud BRACING- TOP CHORD Structural wood sheathing directly applied, except end verticals. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS.(lb/size) 2=376/0-3-8, 4=302/0-1-8 Max Horz 2=57(LC 5) Max Uplift2=-60(LC 4), 4=-27(LC 6) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES-(7-8) 1) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 3) Bearing at joint(s) 4 considers parallel to grain value using ANSI/TPI 1 angle to grain formula. Building designer should verify capacity of bearing surface. 4) Provide mechanical connection (by others) of truss to bearing plate at joint(s) 4. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 2, 4. 6) "Semi-rigid pitchbreaks with fixed heels" Member end fixity model was used in the analysis and design of this truss. 7) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 8) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. May 21,2018 Job B18801553 Truss M02 Truss Type Monopitch Qty 3 Ply 1 CALA 17 CLAY Job Reference (optional) I33391302 7.640 s Aug 16 2017 MiTek Industries, Inc. Sat May 19 15:23:02 2018 Page 1 Builders First Source, mooresville,in ID:mC?hxK0VUR49rWXHgogScbzvq6P-udMSdCG6Mn2nINoRNoVSTX8GnFfBvbLp5CNWArzEulN Scale = 1:19.0 1 2 3 4 2x4 2x4 2x4 -0-11-4 0-11-4 6-3-8 6-3-8 0- 6 - 0 2- 5 - 1 0 2- 2 - 2 0- 3 - 8 2- 5 - 9 3.75 12 LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2006/TPI2002 CSI. TC BC WB (Matrix) 0.57 0.39 0.00 DEFL. Vert(LL) Vert(TL) Horz(TL) in -0.08 -0.19 0.00 (loc) 2-4 2-4 4 l/defl >926 >371 n/a L/d 240 180 n/a PLATES MT20 Weight: 18 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x4 SPF-S Stud BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS.(lb/size) 2=311/0-3-8, 4=234/0-1-8 Max Horz 2=72(LC 5) Max Uplift2=-52(LC 4), 4=-23(LC 6) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES-(7-8) 1) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 3) Bearing at joint(s) 4 considers parallel to grain value using ANSI/TPI 1 angle to grain formula. Building designer should verify capacity of bearing surface. 4) Provide mechanical connection (by others) of truss to bearing plate at joint(s) 4. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 2, 4. 6) "Semi-rigid pitchbreaks with fixed heels" Member end fixity model was used in the analysis and design of this truss. 7) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 8) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. May 21,2018 Job B18801553 Truss PB01 Truss Type Piggyback Qty 21 Ply 1 CALA 17 CLAY Job Reference (optional) I33391303 7.640 s Aug 16 2017 MiTek Industries, Inc. Sat May 19 15:23:03 2018 Page 1 Builders First Source, mooresville,in ID:mC?hxK0VUR49rWXHgogScbzvq6P-MpwqqYHl74AewXNewW0h0lgSRe1Te2wyKs74iIzEulM Scale = 1:33.8 2 3 4 6 1 5 4x6 3x4 3x4 2x4 8-0-0 8-0-0 4-0-0 4-0-0 8-0-0 4-0-0 -0 - 0 - 4 3- 1 1 - 1 2 4- 0 - 0 0- 1 - 0 0- 1 - 8 12.00 12 LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2006/TPI2002 CSI. TC BC WB (Matrix) 0.45 0.26 0.04 DEFL. Vert(LL) Vert(TL) Horz(TL) in n/a n/a 0.00 (loc) - - 4 l/defl n/a n/a n/a L/d 999 999 n/a PLATES MT20 Weight: 21 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF-S Stud BOT CHORD 2x4 SPF-S Stud OTHERS 2x4 SPF-S Stud BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS.All bearings 8-0-0. (lb) - Max Horz 1=-87(LC 4) Max Uplift All uplift 100 lb or less at joint(s) except 1=-242(LC 1), 5=-242(LC 1), 2=-275(LC 6), 4=-254(LC 7) Max Grav All reactions 250 lb or less at joint(s) 1, 5, 6 except 2=444(LC 1), 4=444(LC 1) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES-(11-12) 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Truss designed for wind loads in the plane of the truss only. For studs exposed to wind (normal to the face), see Standard Industry Gable End Details as applicable, or consult qualified building designer as per ANSI/TPI 1. 4) Gable requires continuous bottom chord bearing. 5) Gable studs spaced at 4-0-0 oc. 6) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 7) Bearing at joint(s) 1, 2 considers parallel to grain value using ANSI/TPI 1 angle to grain formula. Building designer should verify capacity of bearing surface. 8) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 242 lb uplift at joint 1, 242 lb uplift at joint 5, 275 lb uplift at joint 2 and 254 lb uplift at joint 4. 9) "Semi-rigid pitchbreaks with fixed heels" Member end fixity model was used in the analysis and design of this truss. 10) See Standard Industry Piggyback Truss Connection Detail for Connection to base truss as applicable, or consult qualified building designer. 11) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 12) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. May 21,2018 Job B18801553 Truss PBE01 Truss Type GABLE Qty 1 Ply 1 CALA 17 CLAY Job Reference (optional) I33391304 7.640 s Aug 16 2017 MiTek Industries, Inc. Sat May 19 15:23:03 2018 Page 1 Builders First Source, mooresville,in ID:mC?hxK0VUR49rWXHgogScbzvq6P-MpwqqYHl74AewXNewW0h0lgYVe4Me2yyKs74iIzEulM Scale = 1:33.8 Sheet Front Full Sheathing 1 Ply 7/16OSB8 2 3 4 5 6 10 9 8 1 7 4x6 2x4 2x4 2x4 2x4 2x4 2x4 2x4 8-0-0 8-0-0 4-0-0 4-0-0 8-0-0 4-0-0 -0 - 0 - 4 3- 1 1 - 1 2 4- 0 - 0 0- 1 - 0 0- 1 - 8 12.00 12 LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2006/TPI2002 CSI. TC BC WB (Matrix) 0.12 0.07 0.04 DEFL. Vert(LL) Vert(TL) Horz(TL) in n/a n/a 0.00 (loc) - - 6 l/defl n/a n/a n/a L/d 999 999 n/a PLATES MT20 Weight: 55 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF-S Stud BOT CHORD 2x4 SPF-S Stud OTHERS 2x4 SPF-S Stud BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS.All bearings 8-0-0. (lb) - Max Horz 1=-87(LC 4) Max Uplift All uplift 100 lb or less at joint(s) 1, 7, 2, 6, 10, 8 Max Grav All reactions 250 lb or less at joint(s) 1, 7, 2, 6, 9, 10, 8 FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES-(11-12) 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Truss designed for wind loads in the plane of the truss only. For studs exposed to wind (normal to the face), see Standard Industry Gable End Details as applicable, or consult qualified building designer as per ANSI/TPI 1. 4) Gable requires continuous bottom chord bearing. 5) Gable studs spaced at 1-4-0 oc. 6) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 7) Bearing at joint(s) 1, 2 considers parallel to grain value using ANSI/TPI 1 angle to grain formula. Building designer should verify capacity of bearing surface. 8) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 1, 7, 2, 6, 10, 8. 9) "Semi-rigid pitchbreaks with fixed heels" Member end fixity model was used in the analysis and design of this truss. 10) See Standard Industry Piggyback Truss Connection Detail for Connection to base truss as applicable, or consult qualified building designer. 11) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 12) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. May 21,2018 Job B18801553 Truss PBE02 Truss Type GABLE Qty 1 Ply 1 CALA 17 CLAY Job Reference (optional) I33391305 7.640 s Aug 16 2017 MiTek Industries, Inc. Sat May 19 15:23:04 2018 Page 1 Builders First Source, mooresville,in ID:mC?hxK0VUR49rWXHgogScbzvq6P-q?UC1uINuOJVYhyqUDXwYyDjF2QbNVC6YWsdEkzEulL Scale = 1:33.8 Sheet Back Full Sheathing 1 Ply 1/2RyDOW8 2 3 4 5 6 10 9 8 1 7 4x6 2x4 2x4 2x4 2x4 2x4 2x4 2x4 8-0-0 8-0-0 4-0-0 4-0-0 8-0-0 4-0-0 -0 - 0 - 4 3- 1 1 - 1 2 4- 0 - 0 0- 1 - 0 0- 1 - 8 12.00 12 LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2006/TPI2002 CSI. TC BC WB (Matrix) 0.12 0.07 0.04 DEFL. Vert(LL) Vert(TL) Horz(TL) in n/a n/a 0.00 (loc) - - 6 l/defl n/a n/a n/a L/d 999 999 n/a PLATES MT20 Weight: 25 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF-S Stud BOT CHORD 2x4 SPF-S Stud OTHERS 2x4 SPF-S Stud BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS.All bearings 8-0-0. (lb) - Max Horz 1=-87(LC 4) Max Uplift All uplift 100 lb or less at joint(s) 1, 7, 2, 6, 10, 8 Max Grav All reactions 250 lb or less at joint(s) 1, 7, 2, 6, 9, 10, 8 FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES-(11-12) 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Truss designed for wind loads in the plane of the truss only. For studs exposed to wind (normal to the face), see Standard Industry Gable End Details as applicable, or consult qualified building designer as per ANSI/TPI 1. 4) Gable requires continuous bottom chord bearing. 5) Gable studs spaced at 1-4-0 oc. 6) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 7) Bearing at joint(s) 1, 2 considers parallel to grain value using ANSI/TPI 1 angle to grain formula. Building designer should verify capacity of bearing surface. 8) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 1, 7, 2, 6, 10, 8. 9) "Semi-rigid pitchbreaks with fixed heels" Member end fixity model was used in the analysis and design of this truss. 10) See Standard Industry Piggyback Truss Connection Detail for Connection to base truss as applicable, or consult qualified building designer. 11) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 12) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. May 21,2018 Job B18801553 Truss T01 Truss Type ROOF SPECIAL Qty 2 Ply 1 CALA 17 CLAY Job Reference (optional) I33391306 7.640 s Aug 16 2017 MiTek Industries, Inc. Sat May 19 15:23:04 2018 Page 1 Builders First Source, mooresville,in ID:mC?hxK0VUR49rWXHgogScbzvq6P-q?UC1uINuOJVYhyqUDXwYyDZF2DINHT6YWsdEkzEulL Scale = 1:80.8 2 3 4 5 6 7 8 9 1 16 15 14 13 12 11 10 8x8 3x8 5x12 2x4 3x6 5x12 5x12 2x4 2x4 3x6 6x8 6x8 3x6 2x4 8x8 2x4 2-0-0 2-0-0 7-5-3 5-5-3 7-5-12 0-0-9 12-11-8 5-5-12 18-0-0 5-0-8 26-11-15 8-11-15 36-0-0 9-0-1 -0-11-4 0-11-4 2-0-0 2-0-0 7-5-3 5-5-3 7-5-12 0-0-9 12-11-8 5-5-12 18-0-0 5-0-8 26-11-15 8-11-15 36-0-0 9-0-1 36-11-4 0-11-4 0- 7 - 6 9- 7 - 6 0- 7 - 6 1- 0 - 0 6.00 12 Plate Offsets (X,Y)-- [1:Edge,0-0-14], [3:0-3-8,Edge], [8:0-4-0,Edge], [14:0-5-0,0-2-12], [17:0-3-0,0-0-12] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2006/TPI2002 CSI. TC BC WB (Matrix-S) 0.76 0.93 0.92 DEFL. Vert(LL) Vert(TL) Horz(TL) in -0.21 -0.60 0.34 (loc) 14 10-12 8 l/defl >999 >716 n/a L/d 240 180 n/a PLATES MT20 Weight: 162 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 *Except* 1-3: 2x8 SP 2400F 2.0E BOT CHORD 2x4 SPF No.2 WEBS 2x4 SPF-S Stud *Except* 5-14,5-12,7-12: 2x4 SPF No.2 WEDGE Right: 2x4 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied. BOT CHORD Rigid ceiling directly applied. WEBS 1 Row at midpt 7-12 REACTIONS.(lb/size) 1=1433/0-3-8, 8=1490/0-3-8 Max Horz 1=-103(LC 7) Max Uplift1=-70(LC 6), 8=-100(LC 7) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-3=-3096/405, 3-4=-2377/369, 4-5=-2339/461, 5-6=-1701/323, 6-7=-1720/275, 7-8=-2470/346 BOT CHORD 2-15=-264/2856, 14-15=-260/2868, 11-12=-187/2112, 10-11=-187/2112, 8-10=-187/2112 WEBS 4-14=-304/144, 3-14=-931/166, 12-14=-6/1402, 5-14=-210/1208, 5-12=-12/396, 7-12=-811/206, 7-10=0/352, 3-15=0/274 NOTES-(6-7) 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 4) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 1 except (jt=lb) 8=100. 5) This truss design requires that a minimum of 7/16” structural wood sheathing be applied directly to the top chord and ½” gypsum sheetrock be applied directly to the bottom chord. 6) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 7) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. May 21,2018 Job B18801553 Truss T02 Truss Type HIP Qty 1 Ply 1 CALA 17 CLAY Job Reference (optional) I33391307 7.640 s Aug 16 2017 MiTek Industries, Inc. Sat May 19 15:23:05 2018 Page 1 Builders First Source, mooresville,in ID:mC?hxK0VUR49rWXHgogScbzvq6P-JC2aFEJ?fiRMAqX02x295AljDSZV6qhFnAcBnAzEulK Scale = 1:81.9 2 3 4 5 6 7 8 9 1 17 16 15 14 13 12 11 10 8x8 5x8 5x12 3x6 5x12 2x4 3x6 5x12 5x12 2x4 2x4 3x8 2x4 4x10 2x4 8x8 2x4 2-0-0 2-0-0 7-5-4 5-5-4 7-10-4 0-5-0 12-11-8 5-1-4 14-0-0 1-0-8 24-11-15 10-11-15 36-0-0 11-0-1 -0-11-4 0-11-4 2-0-0 2-0-0 7-5-4 5-5-4 7-10-4 0-5-0 12-11-8 5-1-4 14-0-0 1-0-8 22-0-0 8-0-0 28-11-15 6-11-15 36-0-0 7-0-1 36-11-4 0-11-4 0- 7 - 6 7- 5 - 4 7- 7 - 6 0- 7 - 6 1- 0 - 0 7- 5 - 4 6.00 12 Plate Offsets (X,Y)-- [1:Edge,0-0-14], [3:0-3-8,Edge], [5:0-6-0,0-0-15], [8:0-4-0,Edge], [14:0-5-8,0-2-8], [18:0-3-0,0-0-12] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2006/TPI2002 CSI. TC BC WB (Matrix-S) 0.81 0.93 0.54 DEFL. Vert(LL) Vert(TL) Horz(TL) in -0.32 -0.95 0.33 (loc) 10-12 10-12 8 l/defl >999 >455 n/a L/d 240 180 n/a PLATES MT20 Weight: 159 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 *Except* 1-3: 2x8 SP 2400F 2.0E BOT CHORD 2x4 SPF No.2 WEBS 2x4 SPF-S Stud *Except* 10-14,5-14: 2x4 SPF No.2 WEDGE Right: 2x4 SPF-S Stud BRACING- TOP CHORD Structural wood sheathing directly applied, except 2-0-0 oc purlins (2-9-7 max.): 4-5. BOT CHORD Rigid ceiling directly applied. WEBS 1 Row at midpt 3-14 REACTIONS.(lb/size) 1=1434/0-3-8, 8=1491/0-3-8 Max Horz 1=-83(LC 7) Max Uplift1=-52(LC 6), 8=-84(LC 7) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-3=-3089/390, 3-4=-2357/322, 4-5=-2006/326, 5-6=-2104/319, 6-7=-2201/297, 7-8=-2491/351 BOT CHORD 2-16=-250/2853, 15-16=-247/2862, 14-15=-247/2862, 8-10=-208/2145 WEBS 13-15=-448/0, 3-14=-910/200, 12-14=0/706, 4-14=0/610, 5-10=0/452, 7-10=-345/191, 10-14=-100/1688, 5-14=-27/428 NOTES-(8-9) 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Provide adequate drainage to prevent water ponding. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 1, 8. 6) This truss design requires that a minimum of 7/16” structural wood sheathing be applied directly to the top chord and ½” gypsum sheetrock be applied directly to the bottom chord. 7) Graphical purlin representation does not depict the size or the orientation of the purlin along the top and/or bottom chord. 8) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 9) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. May 21,2018 Job B18801553 Truss T03 Truss Type ROOF SPECIAL Qty 1 Ply 1 CALA 17 CLAY Job Reference (optional) I33391308 7.640 s Aug 16 2017 MiTek Industries, Inc. Sat May 19 15:23:06 2018 Page 1 Builders First Source, mooresville,in ID:mC?hxK0VUR49rWXHgogScbzvq6P-nOczSaKdP?ZDn_6DceZOeNIvlsvlrByO0qLkJczEulJ Scale = 1:80.0 2 3 4 5 6 7 8 1 15 14 13 12 11 10 9 8x8 3x8 5x12 2x4 3x6 5x12 5x12 2x4 2x4 3x6 6x8 6x8 3x6 2x4 8x8 2x4 2-0-0 2-0-0 7-5-3 5-5-3 7-5-12 0-0-9 12-11-8 5-5-12 18-0-0 5-0-8 26-11-15 8-11-15 36-0-0 9-0-1 -0-11-4 0-11-4 2-0-0 2-0-0 7-5-3 5-5-3 7-5-12 0-0-9 12-11-8 5-5-12 18-0-0 5-0-8 26-11-15 8-11-15 36-0-0 9-0-1 0- 7 - 6 9- 7 - 6 0- 7 - 6 1- 0 - 0 6.00 12 Plate Offsets (X,Y)-- [1:Edge,0-0-14], [3:0-3-8,Edge], [8:0-4-0,Edge], [13:0-4-12,0-2-12], [16:0-3-0,0-0-12] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2006/TPI2002 CSI. TC BC WB (Matrix-S) 0.76 0.93 0.92 DEFL. Vert(LL) Vert(TL) Horz(TL) in -0.21 -0.60 0.34 (loc) 13 9-11 8 l/defl >999 >718 n/a L/d 240 180 n/a PLATES MT20 Weight: 161 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 *Except* 1-3: 2x8 SP 2400F 2.0E BOT CHORD 2x4 SPF No.2 WEBS 2x4 SPF-S Stud *Except* 5-13,5-11,7-11: 2x4 SPF No.2 WEDGE Right: 2x4 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied. BOT CHORD Rigid ceiling directly applied. WEBS 1 Row at midpt 7-11 REACTIONS.(lb/size) 1=1433/0-3-8, 8=1433/0-3-8 Max Horz 1=90(LC 5) Max Uplift1=-70(LC 6), 8=-71(LC 7) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-3=-3098/414, 3-4=-2378/375, 4-5=-2341/467, 5-6=-1703/324, 6-7=-1721/276, 7-8=-2475/349 BOT CHORD 2-14=-300/2858, 13-14=-295/2870, 10-11=-216/2117, 9-10=-216/2117, 8-9=-216/2117 WEBS 4-13=-304/144, 3-13=-931/171, 11-13=-32/1404, 5-13=-218/1209, 5-11=-9/396, 7-11=-816/209, 7-9=0/352, 3-14=0/274 NOTES-(6-7) 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 4) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 1, 8. 5) This truss design requires that a minimum of 7/16” structural wood sheathing be applied directly to the top chord and ½” gypsum sheetrock be applied directly to the bottom chord. 6) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 7) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. May 21,2018 Job B18801553 Truss T04 Truss Type COMMON Qty 10 Ply 1 CALA 17 CLAY Job Reference (optional) I33391309 7.640 s Aug 16 2017 MiTek Industries, Inc. Sat May 19 15:23:06 2018 Page 1 Builders First Source, mooresville,in ID:mC?hxK0VUR49rWXHgogScbzvq6P-nOczSaKdP?ZDn_6DceZOeNI_bsxnrJHO0qLkJczEulJ Scale = 1:62.9 1 2 3 4 5 6 8 7 3x8 4x6 2x4 3x8 2x4 6x10 6x10 11-0-0 11-0-0 22-0-0 11-0-0 5-6-14 5-6-14 11-0-0 5-5-2 16-5-2 5-5-2 22-0-0 5-6-14 22-11-4 0-11-4 0- 6 - 8 7- 1 0 - 8 0- 6 - 8 8.00 12 Plate Offsets (X,Y)-- [1:Edge,0-3-5], [5:0-1-1,Edge] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2006/TPI2002 CSI. TC BC WB (Matrix-S) 0.39 0.80 0.39 DEFL. Vert(LL) Vert(TL) Horz(TL) in -0.21 -0.55 0.03 (loc) 8-11 8-11 5 l/defl >999 >483 n/a L/d 240 180 n/a PLATES MT20 Weight: 77 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x4 SPF-S Stud WEDGE Left: 2x3 SPF No.2, Right: 2x3 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied. BOT CHORD Rigid ceiling directly applied. REACTIONS.(lb/size) 1=879/0-3-8, 5=937/0-3-8 Max Horz 1=-180(LC 4) Max Uplift1=-37(LC 6), 5=-68(LC 7) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 1-2=-1189/138, 2-3=-918/124, 3-4=-918/124, 4-5=-1186/137 BOT CHORD 1-8=-67/951, 7-8=-11/947, 5-7=-11/947 WEBS 3-8=-22/642, 4-8=-340/153, 2-8=-344/156 NOTES-(6-7) 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 4) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 1, 5. 5) This truss design requires that a minimum of 7/16” structural wood sheathing be applied directly to the top chord and ½” gypsum sheetrock be applied directly to the bottom chord. 6) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 7) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. May 21,2018 Job B18801553 Truss T06 Truss Type Piggyback Base Qty 18 Ply 1 CALA 17 CLAY Job Reference (optional) I33391310 7.640 s Aug 16 2017 MiTek Industries, Inc. Sat May 19 15:23:06 2018 Page 1 Builders First Source, mooresville,in ID:9WfuBFvwEjXB7g2IW?GDqxyd85s-nOczSaKdP?ZDn_6DceZOeNIs5sxYrOOO0qLkJczEulJ Scale = 1:74.4 1 2 3 4 5 67 12 11 10 9 8 4x8 4x8 6x8 3x6 3x6 3x8 2x4 3x6 2x4 3x6 4x8 9-4-0 9-4-0 17-4-0 8-0-0 26-8-0 9-4-0 4-9-12 4-9-12 9-4-0 4-6-4 17-4-0 8-0-0 21-10-4 4-6-4 26-8-0 4-9-12 27-7-4 0-11-4 1- 1 - 6 10 - 5 - 6 1- 1 - 6 10 - 5 - 6 12.00 12 Plate Offsets (X,Y)-- [1:0-1-10,0-1-8], [3:0-5-1,0-2-0], [4:0-4-12,0-1-8], [6:0-1-10,0-1-8], [8:Edge,0-1-8] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2006/TPI2002 CSI. TC BC WB (Matrix-S) 0.93 0.81 0.12 DEFL. Vert(LL) Vert(TL) Horz(TL) in -0.15 -0.36 0.04 (loc) 8-9 8-9 8 l/defl >999 >881 n/a L/d 240 180 n/a PLATES MT20 Weight: 126 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x4 SPF No.2 *Except* 2-11,5-9: 2x4 SPF-S Stud, 1-12,6-8: 2x6 SP No.1 BRACING- TOP CHORD Structural wood sheathing directly applied, except end verticals, and 2-0-0 oc purlins (6-0-0 max.): 3-4. BOT CHORD Rigid ceiling directly applied. WEBS 1 Row at midpt 4-11 REACTIONS.(lb/size) 8=1120/0-3-8, 12=1047/Mechanical Max Horz 12=-265(LC 4) Max Uplift8=-56(LC 7), 12=-20(LC 6) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 1-2=-1151/150, 2-3=-947/201, 3-4=-642/195, 4-5=-946/201, 5-6=-1151/151, 1-12=-931/130, 6-8=-1010/170 BOT CHORD 11-12=-151/696, 10-11=-19/642, 9-10=-19/642, 8-9=0/687 WEBS 3-11=-12/342, 4-9=-35/342 NOTES-(9-10) 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Provide adequate drainage to prevent water ponding. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) Refer to girder(s) for truss to truss connections. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 8, 12. 7) This truss design requires that a minimum of 7/16” structural wood sheathing be applied directly to the top chord and ½” gypsum sheetrock be applied directly to the bottom chord. 8) Graphical purlin representation does not depict the size or the orientation of the purlin along the top and/or bottom chord. 9) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 10) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. May 21,2018 Job B18801553 Truss T07 Truss Type PIGGYBACK BASE Qty 3 Ply 1 CALA 17 CLAY Job Reference (optional) I33391311 7.640 s Aug 16 2017 MiTek Industries, Inc. Sat May 19 15:23:07 2018 Page 1 Builders First Source, mooresville,in ID:9WfuBFvwEjXB7g2IW?GDqxyd85s-FaALgwKFAJh4P8gP9M4dAbr1tGHCarpYEU5Hr3zEulI Scale = 1:74.4 1 2 3 4 5 6 78 13 12 11 10 9 4x8 6x8 3x6 3x6 3x8 2x4 3x6 2x4 4x8 3x6 4x8 9-4-0 9-4-0 17-4-0 8-0-0 26-8-0 9-4-0 -0-11-4 0-11-4 4-9-12 4-9-12 9-4-0 4-6-4 17-4-0 8-0-0 21-10-4 4-6-4 26-8-0 4-9-12 27-7-4 0-11-4 1- 1 - 6 10 - 5 - 6 1- 1 - 6 10 - 5 - 6 12.00 12 Plate Offsets (X,Y)-- [2:0-1-10,0-1-8], [4:0-5-1,0-2-0], [5:0-4-12,0-1-8], [7:0-1-10,0-1-8], [9:Edge,0-1-8] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2006/TPI2002 CSI. TC BC WB (Matrix-S) 0.93 0.72 0.11 DEFL. Vert(LL) Vert(TL) Horz(TL) in -0.15 -0.36 0.04 (loc) 9-10 9-10 9 l/defl >999 >885 n/a L/d 240 180 n/a PLATES MT20 Weight: 127 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x4 SPF No.2 *Except* 3-12,6-10: 2x4 SPF-S Stud, 2-13,7-9: 2x6 SP No.1 BRACING- TOP CHORD Structural wood sheathing directly applied, except end verticals, and 2-0-0 oc purlins (6-0-0 max.): 4-5. BOT CHORD Rigid ceiling directly applied. WEBS 1 Row at midpt 5-12 REACTIONS.(lb/size) 13=1118/0-3-8, 9=1118/0-3-8 Max Horz 13=251(LC 5) Max Uplift13=-56(LC 6), 9=-56(LC 7) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-3=-1149/150, 3-4=-944/201, 4-5=-641/196, 5-6=-944/201, 6-7=-1149/151, 2-13=-1008/169, 7-9=-1008/169 BOT CHORD 12-13=-152/686, 11-12=-19/640, 10-11=-19/640, 9-10=0/686 WEBS 4-12=-12/341, 5-10=-35/341 NOTES-(8-9) 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Provide adequate drainage to prevent water ponding. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 13, 9. 6) This truss design requires that a minimum of 7/16” structural wood sheathing be applied directly to the top chord and ½” gypsum sheetrock be applied directly to the bottom chord. 7) Graphical purlin representation does not depict the size or the orientation of the purlin along the top and/or bottom chord. 8) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 9) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. May 21,2018 Job B18801553 Truss T08 Truss Type Common Qty 4 Ply 1 CALA 17 CLAY Job Reference (optional) I33391312 7.640 s Aug 16 2017 MiTek Industries, Inc. Sat May 19 15:23:07 2018 Page 1 Builders First Source, mooresville,in ID:mC?hxK0VUR49rWXHgogScbzvq6P-FaALgwKFAJh4P8gP9M4dAbr9IGH9ao1YEU5Hr3zEulI Scale = 1:54.2 1 2 3 4 5 6 7 8 4x6 6x6 5x12 2x4 2x4 6x6 10-0-0 10-0-0 20-0-0 10-0-0 -0-11-4 0-11-4 5-0-14 5-0-14 10-0-0 4-11-2 14-11-2 4-11-2 20-0-0 5-0-14 20-11-4 0-11-4 0- 6 - 8 7- 2 - 8 0- 6 - 8 8.00 12 Plate Offsets (X,Y)-- [2:0-3-5,Edge], [6:0-3-5,Edge], [8:0-6-0,0-3-0] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2006/TPI2002 CSI. TC BC WB (Matrix) 0.39 0.72 0.29 DEFL. Vert(LL) Vert(TL) Horz(TL) in -0.17 -0.45 0.03 (loc) 2-8 2-8 6 l/defl >999 >523 n/a L/d 240 180 n/a PLATES MT20 Weight: 72 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x4 SPF-S Stud WEDGE Left: 2x3 SPF No.2, Right: 2x3 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 5-2-7 oc purlins. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS.(lb/size) 2=853/0-3-8, 6=853/0-3-8 Max Horz 2=-161(LC 4) Max Uplift2=-68(LC 6), 6=-68(LC 7) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-3=-1059/119, 3-4=-813/108, 4-5=-813/108, 5-6=-1059/119 BOT CHORD 2-8=-57/818, 6-8=-10/818 WEBS 4-8=-21/570, 5-8=-284/145, 3-8=-284/145 NOTES-(6-7) 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 4) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 2, 6. 5) "Semi-rigid pitchbreaks with fixed heels" Member end fixity model was used in the analysis and design of this truss. 6) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 7) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. May 21,2018 Job B18801553 Truss T09 Truss Type Common Qty 1 Ply 1 CALA 17 CLAY Job Reference (optional) I33391313 7.640 s Aug 16 2017 MiTek Industries, Inc. Sat May 19 15:23:08 2018 Page 1 Builders First Source, mooresville,in ID:mC?hxK0VUR49rWXHgogScbzvq6P-jnkjtGLtxcpx1IFbj3csjoNJcfb7JEDhT8qrNVzEulH Scale = 1:62.9 1 2 3 4 5 6 7 9 8 4x6 6x10 3x8 3x8 2x4 2x4 6x10 11-0-0 11-0-0 22-0-0 11-0-0 -0-11-4 0-11-4 5-6-14 5-6-14 11-0-0 5-5-2 16-5-2 5-5-2 22-0-0 5-6-14 22-11-4 0-11-4 0- 6 - 8 7- 1 0 - 8 0- 6 - 8 8.00 12 Plate Offsets (X,Y)-- [2:0-1-1,Edge], [6:0-1-1,Edge] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2006/TPI2002 CSI. TC BC WB (Matrix) 0.48 0.87 0.36 DEFL. Vert(LL) Vert(TL) Horz(TL) in -0.25 -0.66 0.04 (loc) 6-9 6-9 6 l/defl >999 >396 n/a L/d 240 180 n/a PLATES MT20 Weight: 78 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x4 SPF-S Stud WEDGE Left: 2x3 SPF No.2, Right: 2x3 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 4-9-0 oc purlins. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS.(lb/size) 2=933/0-3-8, 6=933/0-3-8 Max Horz 2=177(LC 5) Max Uplift2=-71(LC 6), 6=-71(LC 7) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-3=-1175/133, 3-4=-901/120, 4-5=-901/120, 5-6=-1175/133 BOT CHORD 2-9=-65/912, 8-9=-15/912, 6-8=-15/912 WEBS 4-9=-24/633, 5-9=-319/161, 3-9=-319/161 NOTES-(6-7) 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 4) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 2, 6. 5) "Semi-rigid pitchbreaks with fixed heels" Member end fixity model was used in the analysis and design of this truss. 6) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 7) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. May 21,2018 Job B18801553 Truss T11 Truss Type Common Qty 7 Ply 1 CALA 17 CLAY Job Reference (optional) I33391314 7.640 s Aug 16 2017 MiTek Industries, Inc. Sat May 19 15:23:08 2018 Page 1 Builders First Source, mooresville,in ID:mC?hxK0VUR49rWXHgogScbzvq6P-jnkjtGLtxcpx1IFbj3csjoNM1fjRJA7hT8qrNVzEulH Scale = 1:53.0 1 2 3 4 5 6 7 10 9 8 4x6 4x8 3x6 3x6 2x4 3x6 2x4 4x8 7-5-12 7-5-12 11-10-4 4-4-8 19-4-0 7-5-12 -0-11-4 0-11-4 4-10-14 4-10-14 9-8-0 4-9-2 14-5-2 4-9-2 19-4-0 4-10-14 20-3-4 0-11-4 0- 6 - 8 6- 1 1 - 1 3 0- 6 - 8 8.00 12 Plate Offsets (X,Y)-- [2:0-3-8,Edge], [6:0-3-8,Edge] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2006/TPI2002 CSI. TC BC WB (Matrix) 0.27 0.34 0.62 DEFL. Vert(LL) Vert(TL) Horz(TL) in -0.08 -0.21 0.01 (loc) 6-8 6-8 6 l/defl >999 >681 n/a L/d 240 180 n/a PLATES MT20 Weight: 73 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x4 SPF-S Stud WEDGE Left: 2x3 SPF No.2, Right: 2x3 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS.(lb/size) 2=319/0-3-8, 10=825/0-3-8, 6=509/0-3-8 Max Horz 2=-156(LC 4) Max Uplift2=-35(LC 6), 10=-52(LC 6), 6=-64(LC 7) Max Grav 2=329(LC 10), 10=825(LC 1), 6=509(LC 1) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 4-5=-336/95, 5-6=-498/69 BOT CHORD 6-8=0/363 WEBS 3-10=-280/138, 4-10=-505/30, 4-8=-41/347, 5-8=-265/136 NOTES-(6-7) 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 4) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 2, 10, 6. 5) "Semi-rigid pitchbreaks with fixed heels" Member end fixity model was used in the analysis and design of this truss. 6) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 7) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. May 21,2018 Job B18801553 Truss TG01 Truss Type Hip Girder Qty 1 Ply 2 CALA 17 CLAY Job Reference (optional) I33391315 7.640 s Aug 16 2017 MiTek Industries, Inc. Sat May 19 15:23:09 2018 Page 1 Builders First Source, mooresville,in ID:mC?hxK0VUR49rWXHgogScbzvq6P-BzH55bMViwxoeSqoHn75F0wMK3xb2eMrioaOwxzEulG Scale = 1:66.3 1 23 4 5 6 7 8 9 10 11 18 17 16 15 14 13 12 19 20 21 22 23 24 25 26 27 28 29 30 31 8x8 5x6 5x6 4x8 2x4 3x6 4x10 5x12 2x4 2x4 3x6 3x8 4x8 3x8 3x8 2x4 8x8 2-0-0 2-0-0 7-5-12 5-5-12 12-11-8 5-5-12 19-5-12 6-6-4 26-0-0 6-6-4 36-0-0 10-0-0 -0-11-4 0-11-4 2-0-0 2-0-0 6-0-0 4-0-0 10-0-0 4-0-0 12-11-8 2-11-8 19-5-12 6-6-4 26-0-0 6-6-4 30-9-15 4-9-15 36-0-0 5-2-1 36-11-4 0-11-4 0- 7 - 6 5- 6 - 5 5- 7 - 6 0- 7 - 6 1- 0 - 0 5- 6 - 5 6.00 12 Plate Offsets (X,Y)-- [1:Edge,0-0-1], [5:0-3-0,0-2-7], [8:0-3-0,0-2-7], [10:0-4-0,Edge], [14:0-3-8,0-2-0], [16:0-4-8,0-2-8] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 NO IRC2006/TPI2002 CSI. TC BC WB (Matrix) 1.00 0.85 0.56 DEFL. Vert(LL) Vert(TL) Horz(TL) in 0.33 -0.71 0.30 (loc) 14-15 10-12 10 l/defl >999 >605 n/a L/d 240 180 n/a PLATES MT20 Weight: 307 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 *Except* 1-4: 2x8 SP 2400F 2.0E BOT CHORD 2x4 SPF No.2 *Except* 3-16,10-13: 2x4 SPF 2100F 1.8E WEBS 2x4 SPF-S Stud *Except* 14-16,7-12: 2x4 SPF No.2 WEDGE Right: 2x4 SPF-S Stud BRACING- TOP CHORD Structural wood sheathing directly applied or 4-11-2 oc purlins, except 2-0-0 oc purlins (5-3-5 max.): 5-8. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS.(lb/size) 1=2554/0-3-8, 10=2628/0-3-8 Max Horz 1=-57(LC 6) Max Uplift1=-647(LC 5), 10=-682(LC 6) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 1-2=-1383/386, 2-3=-157/513, 3-4=-6825/1863, 4-5=-5924/1652, 5-6=-5222/1559, 6-7=-5205/1554, 7-8=-3741/1098, 8-9=-4295/1225, 9-10=-4482/1226 BOT CHORD 3-19=-1797/6633, 19-20=-1797/6633, 17-20=-1797/6633, 17-21=-1247/4468, 21-22=-1247/4468, 22-23=-1247/4468, 16-23=-1247/4468, 14-27=-1358/4651, 27-28=-1358/4651, 13-28=-1358/4651, 12-13=-1358/4651, 12-29=-1005/3878, 29-30=-1005/3878, 30-31=-1005/3878, 10-31=-1005/3878 WEBS 15-16=-95/261, 6-16=-344/110, 4-17=-1618/472, 5-17=-446/1591, 5-16=-503/1398, 14-16=-1327/4554, 7-16=-173/702, 7-14=-110/296, 7-12=-1251/468, 8-12=-472/1590 NOTES-(11-12) 1) 2-ply truss to be connected together with 10d (0.131"x3") nails as follows: Top chords connected as follows: 2x8 - 2 rows staggered at 0-9-0 oc, 2x4 - 1 row at 0-9-0 oc. Bottom chords connected as follows: 2x4 - 1 row at 0-9-0 oc. Webs connected as follows: 2x4 - 1 row at 0-9-0 oc. 2) All loads are considered equally applied to all plies, except if noted as front (F) or back (B) face in the LOAD CASE(S) section. Ply to ply connections have been provided to distribute only loads noted as (F) or (B), unless otherwise indicated. 3) Unbalanced roof live loads have been considered for this design. 4) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; enclosed; MWFRS (low-rise) gable end zone; cantilever left and right exposed ; end vertical left and right exposed; Lumber DOL=1.60 plate grip DOL=1.60 5) Provide adequate drainage to prevent water ponding. 6) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) except (jt=lb) 1=647, 10=682. 8) "Semi-rigid pitchbreaks with fixed heels" Member end fixity model was used in the analysis and design of this truss. 9) Graphical purlin representation does not depict the size or the orientation of the purlin along the top and/or bottom chord. Continued on page 2 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. May 21,2018 Job B18801553 Truss TG01 Truss Type Hip Girder Qty 1 Ply 2 CALA 17 CLAY Job Reference (optional) I33391315 7.640 s Aug 16 2017 MiTek Industries, Inc. Sat May 19 15:23:09 2018 Page 2 Builders First Source, mooresville,in ID:mC?hxK0VUR49rWXHgogScbzvq6P-BzH55bMViwxoeSqoHn75F0wMK3xb2eMrioaOwxzEulG NOTES-(11-12) 10) Hanger(s) or other connection device(s) shall be provided sufficient to support concentrated load(s) 225 lb down and 71 lb up at 4-0-12, 140 lb down and 53 lb up at 6-0-12, 140 lb down and 71 lb up at 8-0-12, 140 lb down and 92 lb up at 10-0-12, 140 lb down and 92 lb up at 12-0-12, 140 lb down and 93 lb up at 14-0-12, 140 lb down and 93 lb up at 16-0-12, 140 lb down and 93 lb up at 18-0-0, 140 lb down and 93 lb up at 19-11-4, 140 lb down and 93 lb up at 21-11-4, 140 lb down and 93 lb up at 23-11-4, 140 lb down and 93 lb up at 25-11-4, 140 lb down and 72 lb up at 27-11-4, and 140 lb down and 55 lb up at 29-11-4, and 225 lb down and 71 lb up at 31-11-4 on bottom chord. The design/selection of such connection device(s) is the responsibility of others. 11) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 12) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). LOAD CASE(S) Standard 1) Dead + Roof Live (balanced): Lumber Increase=1.15, Plate Increase=1.15 Uniform Loads (plf) Vert: 1-5=-60, 5-8=-60, 8-11=-60, 1-18=-20, 3-16=-20, 10-15=-20 Concentrated Loads (lb) Vert: 13=-140 12=-140 19=-225 20=-140 21=-140 22=-140 23=-140 24=-140 25=-140 26=-140 27=-140 28=-140 29=-140 30=-140 31=-225 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job B18801553 Truss TG02 Truss Type Common Girder Qty 1 Ply 3 CALA 17 CLAY Job Reference (optional) I33391316 7.640 s Aug 16 2017 MiTek Industries, Inc. Sat May 19 15:23:10 2018 Page 1 Builders First Source, mooresville,in ID:mC?hxK0VUR49rWXHgogScbzvq6P-f9rTIxN8TE3fGcP_rUeKoDTeXTIWn_m_xSJxSOzEulF Scale = 1:78.0 1 2 3 4 5 6 7 8 9 14 13 12 11 1021 22 23 24 25 26 27 28 29 30 31 32 33 34 3x8 6x6 3x8 8x16 5x10 MT18HS 10x10 8x8 10x10 2x4 8x8 10x10 2x4 5x10 MT18HS 8x16 9-2-1 9-2-1 18-0-0 8-9-15 26-9-15 8-9-15 36-0-0 9-2-1 6-2-11 6-2-11 12-1-6 5-10-10 18-0-0 5-10-10 23-10-10 5-10-10 29-9-5 5-10-10 36-0-0 6-2-11 0- 7 - 6 9- 7 - 6 0- 7 - 6 6.00 12 Plate Offsets (X,Y)-- [1:Edge,0-3-5], [9:Edge,0-3-5] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 NO IRC2006/TPI2002 CSI. TC BC WB (Matrix-M) 0.52 0.81 1.00 DEFL. Vert(LL) Vert(TL) Horz(TL) in -0.29 -0.71 0.14 (loc) 12-14 12-14 9 l/defl >999 >605 n/a L/d 240 180 n/a PLATES MT20 MT18HS Weight: 563 lb FT = 20% GRIP 169/123 244/190 LUMBER- TOP CHORD 2x4 SPF 2100F 1.8E BOT CHORD 2x6 SP 2400F 2.0E WEBS 2x4 SPF-S Stud *Except* 5-12,6-12,4-12: 2x4 SPF No.2 WEDGE Left: 2x8 SP 2400F 2.0E, Right: 2x8 SP 2400F 2.0E BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS.(lb/size) 1=10142/0-3-8, 9=10193/0-3-8 Max Horz 1=-88(LC 3) Max Uplift1=-338(LC 5), 9=-339(LC 6) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 1-2=-17921/630, 2-3=-17701/606, 3-4=-17605/622, 4-5=-12161/476, 5-6=-12161/476, 6-7=-17593/622, 7-8=-17689/605, 8-9=-17911/630 BOT CHORD 1-21=-583/15985, 21-22=-583/15985, 22-23=-583/15985, 23-24=-583/15985, 14-24=-583/15985, 14-25=-424/13453, 13-25=-424/13453, 13-26=-424/13453, 26-27=-424/13453, 12-27=-424/13453, 12-28=-349/13446, 28-29=-349/13446, 11-29=-349/13446, 11-30=-349/13446, 10-30=-349/13446, 10-31=-499/15977, 31-32=-499/15977, 32-33=-499/15977, 33-34=-499/15977, 9-34=-499/15977 WEBS 5-12=-332/10454, 6-12=-3877/256, 6-10=-149/5452, 8-10=-332/140, 4-12=-3886/257, 4-14=-149/5465, 2-14=-327/140 NOTES-(10-11) 1) 3-ply truss to be connected together with 10d (0.131"x3") nails as follows: Top chords connected as follows: 2x4 - 1 row at 0-9-0 oc. Bottom chords connected as follows: 2x6 - 2 rows staggered at 0-7-0 oc. Webs connected as follows: 2x4 - 1 row at 0-9-0 oc. 2) All loads are considered equally applied to all plies, except if noted as front (F) or back (B) face in the LOAD CASE(S) section. Ply to ply connections have been provided to distribute only loads noted as (F) or (B), unless otherwise indicated. 3) Unbalanced roof live loads have been considered for this design. 4) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; enclosed; MWFRS (low-rise) gable end zone; cantilever left and right exposed ; end vertical left and right exposed; Lumber DOL=1.60 plate grip DOL=1.60 5) All plates are MT20 plates unless otherwise indicated. 6) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) except (jt=lb) 1=338, 9=339. 8) "Semi-rigid pitchbreaks with fixed heels" Member end fixity model was used in the analysis and design of this truss. 9) Hanger(s) or other connection device(s) shall be provided sufficient to support concentrated load(s) 1027 lb down and 32 lb up at 2-0-12, 1027 lb down and 32 lb up at 4-0-12, 1027 lb down and 32 lb up at 6-0-12, 1027 lb down and 32 lb up at 8-0-12, 1027 lb down and 32 lb up at 10-0-12, 1027 lb down and 32 lb up at 12-0-12, 1027 lb down and 32 lb up at 14-0-12, 1027 lb down and 32 lb up at 16-0-12, 1027 lb down and 32 lb up at 18-0-12, 1027 lb down and 32 lb up at 20-0-12, 1027 lb down and 32 lb up at 22-0-12, 1027 lb down and 32 lb up at 24-0-12, 1027 lb down and 32 lb up at 26-0-12, 1027 lb down and 32 lb up at 28-0-12, 1027 lb down and 32 lb up at 30-0-12, and 1027 lb down and 32 lb up at 32-0-12, and 1027 lb down and 32 lb up at 34-0-12 on bottom chord. The design/selection of such connection device(s) is the responsibility of others.Continued on page 2 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. May 21,2018 Job B18801553 Truss TG02 Truss Type Common Girder Qty 1 Ply 3 CALA 17 CLAY Job Reference (optional) I33391316 7.640 s Aug 16 2017 MiTek Industries, Inc. Sat May 19 15:23:10 2018 Page 2 Builders First Source, mooresville,in ID:mC?hxK0VUR49rWXHgogScbzvq6P-f9rTIxN8TE3fGcP_rUeKoDTeXTIWn_m_xSJxSOzEulF 10) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 11) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). LOAD CASE(S) Standard 1) Dead + Roof Live (balanced): Lumber Increase=1.15, Plate Increase=1.15 Uniform Loads (plf) Vert: 1-5=-60, 5-9=-60, 15-18=-20 Concentrated Loads (lb) Vert: 13=-1027(B) 12=-1027(B) 11=-1027(B) 21=-1027(B) 22=-1027(B) 23=-1027(B) 24=-1027(B) 25=-1027(B) 26=-1027(B) 27=-1027(B) 28=-1027(B) 29=-1027(B) 30=-1027(B) 31=-1027(B) 32=-1027(B) 33=-1027(B) 34=-1027(B) 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job B18801553 Truss TG03 Truss Type Half Hip Girder Qty 1 Ply 1 CALA 17 CLAY Job Reference (optional) I33391317 7.640 s Aug 16 2017 MiTek Industries, Inc. Sat May 19 15:23:11 2018 Page 1 Builders First Source, mooresville,in ID:mC?hxK0VUR49rWXHgogScbzvq6P-7MPsVHNmEXBWul_AOB9ZLR?q6tbzWZy8963V_qzEulE Scale = 1:17.7 1 2 3 4 6 57 4x8 2x4 3x4 3x4 3x8 3-1-12 3-1-12 5-0-0 1-10-4 6-3-8 1-3-8 -0-11-4 0-11-4 5-0-0 5-0-0 6-3-8 1-3-8 0- 6 - 0 2- 0 - 1 2 1- 9 - 4 0- 3 - 8 2- 0 - 1 2 3.75 12 Plate Offsets (X,Y)-- [2:0-0-7,0-1-8] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 NO IRC2006/TPI2002 CSI. TC BC WB (Matrix) 0.47 0.99 0.49 DEFL. Vert(LL) Vert(TL) Horz(TL) in -0.06 -0.09 0.01 (loc) 5-6 5-6 5 l/defl >999 >779 n/a L/d 240 180 n/a PLATES MT20 Weight: 21 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x4 SPF-S Stud BRACING- TOP CHORD Structural wood sheathing directly applied or 4-11-7 oc purlins, except end verticals, and 2-0-0 oc purlins: 3-4. BOT CHORD Rigid ceiling directly applied or 9-10-2 oc bracing. REACTIONS.(lb/size) 2=526/0-3-8, 5=932/0-1-8 Max Horz 2=61(LC 4) Max Uplift2=-151(LC 3), 5=-237(LC 3) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-3=-1054/319 BOT CHORD 2-6=-307/941, 6-7=-91/268, 5-7=-91/268 WEBS 3-5=-493/160, 3-6=-287/891 NOTES-(10-11) 1) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; enclosed; MWFRS (low-rise) gable end zone; cantilever left and right exposed ; end vertical left and right exposed; Lumber DOL=1.60 plate grip DOL=1.60 2) Provide adequate drainage to prevent water ponding. 3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 4) Bearing at joint(s) 5 considers parallel to grain value using ANSI/TPI 1 angle to grain formula. Building designer should verify capacity of bearing surface. 5) Provide mechanical connection (by others) of truss to bearing plate at joint(s) 5. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) except (jt=lb) 2=151, 5=237. 7) "Semi-rigid pitchbreaks with fixed heels" Member end fixity model was used in the analysis and design of this truss. 8) Graphical purlin representation does not depict the size or the orientation of the purlin along the top and/or bottom chord. 9) Hanger(s) or other connection device(s) shall be provided sufficient to support concentrated load(s) 620 lb down and 279 lb up at 4-0-12, and 293 lb down and 34 lb up at 6-1-12 on bottom chord. The design/selection of such connection device(s) is the responsibility of others. 10) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 11) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). LOAD CASE(S) Standard 1) Dead + Roof Live (balanced): Lumber Increase=1.15, Plate Increase=1.15 Uniform Loads (plf) Vert: 1-3=-60, 3-4=-60, 2-5=-20 Concentrated Loads (lb) Vert: 5=-293 7=-620 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. May 21,2018 Job B18801553 Truss TG04 Truss Type Half Hip Girder Qty 1 Ply 1 CALA 17 CLAY Job Reference (optional) I33391318 7.640 s Aug 16 2017 MiTek Industries, Inc. Sat May 19 15:23:11 2018 Page 1 Builders First Source, mooresville,in ID:mC?hxK0VUR49rWXHgogScbzvq6P-7MPsVHNmEXBWul_AOB9ZLR?lvtncWc_8963V_qzEulE Scale = 1:17.8 1 2 3 4 6 5 2x4 3x4 4x6 2x4 3x8 6-6-0 6-6-0 8-0-0 1-6-0 -0-11-4 0-11-4 6-6-0 6-6-0 8-0-0 1-6-0 0- 4 - 1 2 1- 9 - 0 1- 5 - 8 0- 3 - 8 1- 9 - 0 2.50 12 Plate Offsets (X,Y)-- [2:0-1-5,Edge] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 NO IRC2006/TPI2002 CSI. TC BC WB (Matrix) 0.80 0.24 0.29 DEFL. Vert(LL) Vert(TL) Horz(TL) in -0.04 -0.10 0.01 (loc) 2-6 2-6 5 l/defl >999 >898 n/a L/d 240 180 n/a PLATES MT20 Weight: 23 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF 2100F 1.8E WEBS 2x4 SPF-S Stud BRACING- TOP CHORD Structural wood sheathing directly applied or 4-8-2 oc purlins, except end verticals, and 2-0-0 oc purlins: 3-4. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS.(lb/size) 2=459/0-3-8, 5=640/0-1-8 Max Horz 2=48(LC 4) Max Uplift2=-119(LC 3), 5=-267(LC 3) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-3=-679/232 BOT CHORD 2-6=-218/627, 5-6=-197/573 WEBS 3-5=-842/307, 3-6=-208/538 NOTES-(11-12) 1) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; enclosed; MWFRS (low-rise) gable end zone; cantilever left and right exposed ; end vertical left and right exposed; Lumber DOL=1.60 plate grip DOL=1.60 2) Provide adequate drainage to prevent water ponding. 3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 4) Bearing at joint(s) 5 considers parallel to grain value using ANSI/TPI 1 angle to grain formula. Building designer should verify capacity of bearing surface. 5) Provide mechanical connection (by others) of truss to bearing plate at joint(s) 5. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) except (jt=lb) 2=119, 5=267. 7) "Semi-rigid pitchbreaks with fixed heels" Member end fixity model was used in the analysis and design of this truss. 8) Graphical purlin representation does not depict the size or the orientation of the purlin along the top and/or bottom chord. 9) Hanger(s) or other connection device(s) shall be provided sufficient to support concentrated load(s) 418 lb down and 300 lb up at 6-6-0 on bottom chord. The design/selection of such connection device(s) is the responsibility of others. 10) In the LOAD CASE(S) section, loads applied to the face of the truss are noted as front (F) or back (B). 11) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 12) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). LOAD CASE(S) Standard 1) Dead + Roof Live (balanced): Lumber Increase=1.15, Plate Increase=1.15 Uniform Loads (plf) Vert: 1-3=-60, 3-4=-60, 2-5=-20 Concentrated Loads (lb) Vert: 6=-418(B) 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. May 21,2018 Job B18801553 Truss TG05 Truss Type COMMON GIRDER Qty 1 Ply 2 CALA 17 CLAY Job Reference (optional) I33391319 7.640 s Aug 16 2017 MiTek Industries, Inc. Sat May 19 15:23:12 2018 Page 1 Builders First Source, mooresville,in ID:mC?hxK0VUR49rWXHgogScbzvq6P-bYzEjdOO?rJMVvZMyvgoteYy6HyhFuPHOmo2WGzEulD Scale = 1:57.6 1 2 3 4 5 8 7 69 10 11 12 13 14 15 164x10 6x6 4x10 4x6 10x10 2x4 10x10 2x4 6-9-10 6-9-10 13-2-6 6-4-13 20-0-0 6-9-10 5-2-6 5-2-6 10-0-0 4-9-10 14-9-10 4-9-10 20-0-0 5-2-6 0- 6 - 8 7- 2 - 8 0- 6 - 8 8.00 12 Plate Offsets (X,Y)-- [1:Edge,0-1-10], [5:Edge,0-1-10] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 NO IRC2006/TPI2002 CSI. TC BC WB (Matrix) 0.64 0.96 0.99 DEFL. Vert(LL) Vert(TL) Horz(TL) in -0.12 -0.30 0.05 (loc) 5-6 5-6 5 l/defl >999 >790 n/a L/d 240 180 n/a PLATES MT20 Weight: 191 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x6 SP No.1 WEBS 2x4 SPF-S Stud BRACING- TOP CHORD Structural wood sheathing directly applied or 4-1-11 oc purlins. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS.(lb/size) 1=4631/0-3-8, 5=4675/0-3-8 Max Horz 1=-158(LC 11) Max Uplift1=-255(LC 5), 5=-257(LC 6) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 1-2=-6326/373, 2-3=-6190/428, 3-4=-6189/428, 4-5=-6324/373 BOT CHORD 1-9=-301/5127, 9-10=-301/5127, 10-11=-301/5127, 8-11=-301/5127, 8-12=-136/3544, 12-13=-136/3544, 7-13=-136/3544, 6-7=-136/3544, 6-14=-244/5127, 14-15=-244/5127, 15-16=-244/5127, 5-16=-244/5127 WEBS 3-6=-248/3607, 3-8=-248/3610 NOTES-(9-10) 1) 2-ply truss to be connected together with 10d (0.131"x3") nails as follows: Top chords connected as follows: 2x4 - 1 row at 0-9-0 oc. Bottom chords connected as follows: 2x6 - 2 rows staggered at 0-9-0 oc. Webs connected as follows: 2x4 - 1 row at 0-9-0 oc. 2) All loads are considered equally applied to all plies, except if noted as front (F) or back (B) face in the LOAD CASE(S) section. Ply to ply connections have been provided to distribute only loads noted as (F) or (B), unless otherwise indicated. 3) Unbalanced roof live loads have been considered for this design. 4) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; enclosed; MWFRS (low-rise) gable end zone; cantilever left and right exposed ; end vertical left and right exposed; Lumber DOL=1.60 plate grip DOL=1.60 5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) except (jt=lb) 1=255, 5=257. 7) "Semi-rigid pitchbreaks with fixed heels" Member end fixity model was used in the analysis and design of this truss. 8) Hanger(s) or other connection device(s) shall be provided sufficient to support concentrated load(s) 859 lb down and 49 lb up at 2-0-12, 859 lb down and 49 lb up at 4-0-12, 859 lb down and 49 lb up at 6-0-12, 859 lb down and 49 lb up at 8-0-12, 859 lb down and 49 lb up at 10-0-12, 859 lb down and 49 lb up at 12-0-12, 859 lb down and 49 lb up at 14-0-12, and 859 lb down and 49 lb up at 16-0-12, and 859 lb down and 49 lb up at 18-0-12 on bottom chord. The design/selection of such connection device(s) is the responsibility of others. 9) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 10) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). LOAD CASE(S) Standard 1) Dead + Roof Live (balanced): Lumber Increase=1.15, Plate Increase=1.15 Uniform Loads (plf) Vert: 1-3=-60, 3-5=-60, 1-5=-20 Concentrated Loads (lb) Vert: 7=-859(B) 9=-859(B) 10=-859(B) 11=-859(B) 12=-859(B) 13=-859(B) 14=-859(B) 15=-859(B) 16=-859(B) 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. May 21,2018 Job B18801553 Truss TG07 Truss Type Common Girder Qty 1 Ply 1 CALA 17 CLAY Job Reference (optional) I33391320 7.640 s Aug 16 2017 MiTek Industries, Inc. Sat May 19 15:23:12 2018 Page 1 Builders First Source, mooresville,in ID:mC?hxK0VUR49rWXHgogScbzvq6P-bYzEjdOO?rJMVvZMyvgoteYvUH?8F0vHOmo2WGzEulD Scale = 1:22.6 1 2 3 5 46 7 8 9 10 11 4x6 3x4 3x4 6x6 6x6 4-2-3 4-2-3 7-9-13 3-7-9 12-0-0 4-2-3 6-0-0 6-0-0 12-0-0 6-0-0 0- 6 - 1 2 2- 9 - 1 2 0- 6 - 1 2 4.50 12 LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 NO IRC2006/TPI2002 CSI. TC BC WB (Matrix) 0.88 0.74 0.51 DEFL. Vert(LL) Vert(TL) Horz(TL) in -0.06 -0.15 0.04 (loc) 3-4 3-4 3 l/defl >999 >965 n/a L/d 240 180 n/a PLATES MT20 Weight: 35 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF 2100F 1.8E WEBS 2x4 SPF-S Stud WEDGE Left: 2x3 SPF No.2, Right: 2x3 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 3-3-10 oc purlins. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS.(lb/size) 1=1383/0-3-8, 3=1298/0-3-8 Max Horz 1=-24(LC 6) Max Uplift1=-134(LC 5), 3=-126(LC 6) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 1-2=-2353/212, 2-3=-2357/214 BOT CHORD 1-6=-166/2104, 6-7=-166/2104, 5-7=-166/2104, 5-8=-131/1554, 8-9=-131/1554, 4-9=-131/1554, 4-10=-154/2107, 10-11=-154/2107, 3-11=-154/2107 WEBS 2-4=-59/927, 2-5=-57/921 NOTES-(8-9) 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; enclosed; MWFRS (low-rise) gable end zone; cantilever left and right exposed ; end vertical left and right exposed; Lumber DOL=1.60 plate grip DOL=1.60 3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 4) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) except (jt=lb) 1=134, 3=126. 5) "Semi-rigid pitchbreaks with fixed heels" Member end fixity model was used in the analysis and design of this truss. 6) Hanger(s) or other connection device(s) shall be provided sufficient to support concentrated load(s) 294 lb down and 33 lb up at 0-8-12, 290 lb down and 36 lb up at 2-8-12, 290 lb down and 36 lb up at 4-8-12, 290 lb down and 36 lb up at 6-8-12, and 290 lb down and 36 lb up at 8-8-12, and 290 lb down and 36 lb up at 10-8-12 on bottom chord. The design/selection of such connection device(s) is the responsibility of others. 7) In the LOAD CASE(S) section, loads applied to the face of the truss are noted as front (F) or back (B). 8) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 9) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). LOAD CASE(S) Standard 1) Dead + Roof Live (balanced): Lumber Increase=1.15, Plate Increase=1.15 Uniform Loads (plf) Vert: 1-2=-60, 2-3=-60, 1-3=-20 Concentrated Loads (lb) Vert: 6=-294(B) 7=-290(B) 8=-290(B) 9=-290(B) 10=-290(B) 11=-290(B) 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. May 21,2018 Job B18801553 Truss V01 Truss Type Valley Qty 1 Ply 1 CALA 17 CLAY Job Reference (optional) I33391321 7.640 s Aug 16 2017 MiTek Industries, Inc. Sat May 19 15:23:13 2018 Page 1 Builders First Source, mooresville,in ID:mC?hxK0VUR49rWXHgogScbzvq6P-4kXcwzP0m9RD738ZWcB1Qs5FDgTE_Y5QdQYc3jzEulC Scale = 1:53.6 1 2 3 4 5 6 7 12 11 10 9 83x6 4x6 3x6 5x6 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 0-0-8 0-0-8 26-3-3 26-2-11 13-1-9 13-1-9 26-3-3 13-1-9 0- 0 - 4 6- 6 - 1 3 0- 0 - 4 6.00 12 Plate Offsets (X,Y)-- [10:0-3-0,0-3-0] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2006/TPI2002 CSI. TC BC WB (Matrix) 0.17 0.17 0.19 DEFL. Vert(LL) Vert(TL) Horz(TL) in n/a n/a 0.00 (loc) - - 7 l/defl n/a n/a n/a L/d 999 999 n/a PLATES MT20 Weight: 79 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 OTHERS 2x4 SPF-S Stud BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS.All bearings 26-2-3. (lb) - Max Horz 1=-61(LC 4) Max Uplift All uplift 100 lb or less at joint(s) 11, 12, 9, 8 Max Grav All reactions 250 lb or less at joint(s) 1, 7 except 10=279(LC 1), 11=318(LC 10), 12=390(LC 1), 9=318(LC 11), 8=390(LC 1) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. WEBS 2-12=-276/134, 6-8=-276/134 NOTES-(7-8) 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Gable requires continuous bottom chord bearing. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 11, 12, 9, 8. 6) "Semi-rigid pitchbreaks with fixed heels" Member end fixity model was used in the analysis and design of this truss. 7) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 8) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. May 21,2018 Job B18801553 Truss V02 Truss Type Valley Qty 1 Ply 1 CALA 17 CLAY Job Reference (optional) I33391322 7.640 s Aug 16 2017 MiTek Industries, Inc. Sat May 19 15:23:13 2018 Page 1 Builders First Source, mooresville,in ID:mC?hxK0VUR49rWXHgogScbzvq6P-4kXcwzP0m9RD738ZWcB1Qs5EsgTp_ZlQdQYc3jzEulC Scale = 1:37.2 1 2 3 4 5 8 7 63x6 4x6 3x6 5x6 2x4 2x4 2x4 2x4 0-0-8 0-0-8 18-3-3 18-2-11 9-1-9 9-1-9 18-3-3 9-1-9 0- 0 - 4 4- 6 - 1 3 0- 0 - 4 6.00 12 Plate Offsets (X,Y)-- [7:0-3-0,0-3-0] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2006/TPI2002 CSI. TC BC WB (Matrix) 0.20 0.13 0.08 DEFL. Vert(LL) Vert(TL) Horz(TL) in n/a n/a 0.00 (loc) - - 5 l/defl n/a n/a n/a L/d 999 999 n/a PLATES MT20 Weight: 50 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 OTHERS 2x4 SPF-S Stud BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS.All bearings 18-2-3. (lb) - Max Horz 1=-41(LC 4) Max Uplift All uplift 100 lb or less at joint(s) 1, 5, 8, 6 Max Grav All reactions 250 lb or less at joint(s) 1, 5, 7 except 8=412(LC 10), 6=412(LC 11) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. WEBS 2-8=-298/143, 4-6=-298/143 NOTES-(7-8) 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Gable requires continuous bottom chord bearing. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 1, 5, 8, 6. 6) "Semi-rigid pitchbreaks with fixed heels" Member end fixity model was used in the analysis and design of this truss. 7) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 8) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. May 21,2018 Job B18801553 Truss V03 Truss Type Valley Qty 1 Ply 1 CALA 17 CLAY Job Reference (optional) I33391323 7.640 s Aug 16 2017 MiTek Industries, Inc. Sat May 19 15:23:13 2018 Page 1 Builders First Source, mooresville,in ID:mC?hxK0VUR49rWXHgogScbzvq6P-4kXcwzP0m9RD738ZWcB1Qs5DGgSL_Z0QdQYc3jzEulC Scale = 1:21.5 1 2 3 43x8 4x6 3x8 2x4 0-0-8 0-0-8 10-3-3 10-2-11 5-1-9 5-1-9 10-3-3 5-1-9 0- 0 - 4 2- 6 - 1 3 0- 0 - 4 6.00 12 LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2006/TPI2002 CSI. TC BC WB (Matrix) 0.30 0.23 0.07 DEFL. Vert(LL) Vert(TL) Horz(TL) in n/a n/a 0.00 (loc) - - 3 l/defl n/a n/a n/a L/d 999 999 n/a PLATES MT20 Weight: 23 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF-S Stud BOT CHORD 2x4 SPF No.2 OTHERS 2x4 SPF-S Stud BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS.(lb/size) 1=161/10-2-3, 3=161/10-2-3, 4=399/10-2-3 Max Horz 1=-22(LC 4) Max Uplift1=-17(LC 6), 3=-20(LC 7), 4=-2(LC 6) Max Grav 1=164(LC 10), 3=164(LC 11), 4=399(LC 1) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES-(7-8) 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Gable requires continuous bottom chord bearing. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 1, 3, 4. 6) "Semi-rigid pitchbreaks with fixed heels" Member end fixity model was used in the analysis and design of this truss. 7) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 8) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. May 21,2018 Job B18801553 Truss V04 Truss Type Valley Qty 1 Ply 1 CALA 17 CLAY Job Reference (optional) I33391324 7.640 s Aug 16 2017 MiTek Industries, Inc. Sat May 19 15:23:14 2018 Page 1 Builders First Source, mooresville,in ID:mC?hxK0VUR49rWXHgogScbzvq6P-Yx5_8JQeXSZ4lDjl4KjGy3dQD4pOj0dar4H9b9zEulB Scale = 1:41.9 1 2 3 4 5 9 8 7 63x4 4x6 3x4 3x6 2x4 2x4 2x4 2x4 2x4 16-0-13 16-0-13 16-1-3 0-0-6 8-0-10 8-0-10 16-1-3 8-0-10 0- 0 - 4 5- 4 - 6 0- 0 - 4 8.00 12 LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2006/TPI2002 CSI. TC BC WB (Matrix) 0.16 0.17 0.11 DEFL. Vert(LL) Vert(TL) Horz(TL) in n/a n/a 0.00 (loc) - - 5 l/defl n/a n/a n/a L/d 999 999 n/a PLATES MT20 Weight: 47 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 *Except* 5-7: 2x4 SPF-S Stud OTHERS 2x4 SPF-S Stud BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS.All bearings 16-0-7. (lb) - Max Horz 1=117(LC 5) Max Uplift All uplift 100 lb or less at joint(s) 1, 9, 6 Max Grav All reactions 250 lb or less at joint(s) 1, 5, 8 except 9=359(LC 10), 6=358(LC 11) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. WEBS 2-9=-265/138, 4-6=-268/138 NOTES-(7-8) 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Gable requires continuous bottom chord bearing. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 1, 9, 6. 6) "Semi-rigid pitchbreaks with fixed heels" Member end fixity model was used in the analysis and design of this truss. 7) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 8) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. May 21,2018 Job B18801553 Truss V05 Truss Type Valley Qty 1 Ply 1 CALA 17 CLAY Job Reference (optional) I33391325 7.640 s Aug 16 2017 MiTek Industries, Inc. Sat May 19 15:23:14 2018 Page 1 Builders First Source, mooresville,in ID:mC?hxK0VUR49rWXHgogScbzvq6P-Yx5_8JQeXSZ4lDjl4KjGy3dNj4qbj0Car4H9b9zEulB Scale: 3/8"=1' 1 2 3 4 5 8 7 63x4 4x6 3x4 2x4 2x4 2x4 2x4 2x4 0-0-6 0-0-6 12-1-3 12-0-13 6-0-10 6-0-10 12-1-3 6-0-10 0- 0 - 4 4- 0 - 6 0- 0 - 4 8.00 12 LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2006/TPI2002 CSI. TC BC WB (Matrix) 0.38 0.10 0.07 DEFL. Vert(LL) Vert(TL) Horz(TL) in n/a n/a 0.00 (loc) - - 5 l/defl n/a n/a n/a L/d 999 999 n/a PLATES MT20 Weight: 32 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF-S Stud BOT CHORD 2x4 SPF No.2 OTHERS 2x4 SPF-S Stud BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS.All bearings 12-0-7. (lb) - Max Horz 1=-86(LC 4) Max Uplift All uplift 100 lb or less at joint(s) 1, 5, 8, 6 Max Grav All reactions 250 lb or less at joint(s) 1, 5 except 7=265(LC 1), 8=295(LC 10), 6=295(LC 11) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES-(7-8) 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Gable requires continuous bottom chord bearing. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 1, 5, 8, 6. 6) "Semi-rigid pitchbreaks with fixed heels" Member end fixity model was used in the analysis and design of this truss. 7) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 8) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. May 21,2018 Job B18801553 Truss V06 Truss Type Valley Qty 1 Ply 1 CALA 17 CLAY Job Reference (optional) I33391326 7.640 s Aug 16 2017 MiTek Industries, Inc. Sat May 19 15:23:14 2018 Page 1 Builders First Source, mooresville,in ID:mC?hxK0VUR49rWXHgogScbzvq6P-Yx5_8JQeXSZ4lDjl4KjGy3dMu4jHj1Jar4H9b9zEulB Scale = 1:22.5 1 2 3 2x4 3x4 2x4 8-0-13 8-0-13 8-1-3 0-0-6 4-0-10 4-0-10 8-1-3 4-0-10 0- 0 - 4 2- 8 - 6 0- 0 - 4 8.00 12 Plate Offsets (X,Y)-- [2:0-2-0,Edge] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2006/TPI2002 CSI. TC BC WB (Matrix) 0.43 0.56 0.00 DEFL. Vert(LL) Vert(TL) Horz(TL) in n/a n/a 0.00 (loc) - - 3 l/defl n/a n/a n/a L/d 999 999 n/a PLATES MT20 Weight: 18 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF-S Stud BOT CHORD 2x4 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS.(lb/size) 1=285/8-0-7, 3=285/8-0-7 Max Horz 1=55(LC 5) Max Uplift1=-12(LC 6), 3=-12(LC 7) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES-(7-8) 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Gable requires continuous bottom chord bearing. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 1, 3. 6) "Semi-rigid pitchbreaks with fixed heels" Member end fixity model was used in the analysis and design of this truss. 7) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 8) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. May 21,2018 Job B18801553 Truss V07 Truss Type Valley Qty 1 Ply 1 CALA 17 CLAY Job Reference (optional) I33391327 7.640 s Aug 16 2017 MiTek Industries, Inc. Sat May 19 15:23:15 2018 Page 1 Builders First Source, mooresville,in ID:mC?hxK0VUR49rWXHgogScbzvq6P-07fMLfRGImhxMNIxd1EVVHAc6U8rSUZj4k1i7bzEulA Scale = 1:11.5 1 2 3 2x4 3x4 2x4 0-0-6 0-0-6 4-1-3 4-0-13 2-0-10 2-0-10 4-1-3 2-0-10 0- 0 - 4 1- 4 - 6 0- 0 - 4 8.00 12 Plate Offsets (X,Y)-- [2:0-2-0,Edge] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2006/TPI2002 CSI. TC BC WB (Matrix) 0.08 0.22 0.00 DEFL. Vert(LL) Vert(TL) Horz(TL) in n/a n/a 0.00 (loc) - - 3 l/defl n/a n/a n/a L/d 999 999 n/a PLATES MT20 Weight: 8 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF-S Stud BOT CHORD 2x4 SPF-S Stud BRACING- TOP CHORD Structural wood sheathing directly applied or 4-1-3 oc purlins. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS.(lb/size) 1=125/4-0-7, 3=125/4-0-7 Max Horz 1=-24(LC 4) Max Uplift1=-5(LC 6), 3=-5(LC 7) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES-(7-8) 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Gable requires continuous bottom chord bearing. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 1, 3. 6) "Semi-rigid pitchbreaks with fixed heels" Member end fixity model was used in the analysis and design of this truss. 7) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 8) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. May 21,2018 Job B18801553 Truss V13 Truss Type Valley Qty 1 Ply 1 CALA 17 CLAY Job Reference (optional) I33391328 7.640 s Aug 16 2017 MiTek Industries, Inc. Sat May 19 15:23:15 2018 Page 1 Builders First Source, mooresville,in ID:mC?hxK0VUR49rWXHgogScbzvq6P-07fMLfRGImhxMNIxd1EVVHAZzU80STYj4k1i7bzEulA Scale = 1:18.3 1 2 3 4 3x8 4x6 3x8 2x4 10-4-10 10-4-10 10-5-4 0-0-11 5-2-10 5-2-10 10-5-4 5-2-10 0- 0 - 4 1- 1 1 - 8 0- 0 - 4 4.50 12 LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2006/TPI2002 CSI. TC BC WB (Matrix) 0.28 0.21 0.07 DEFL. Vert(LL) Vert(TL) Horz(TL) in n/a n/a 0.00 (loc) - - 3 l/defl n/a n/a n/a L/d 999 999 n/a PLATES MT20 Weight: 22 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF-S Stud BOT CHORD 2x4 SPF No.2 OTHERS 2x4 SPF-S Stud BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS.(lb/size) 1=149/10-3-15, 3=149/10-3-15, 4=402/10-3-15 Max Horz 1=16(LC 6) Max Uplift1=-16(LC 6), 3=-18(LC 7), 4=-4(LC 6) Max Grav 1=155(LC 10), 3=155(LC 11), 4=402(LC 1) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES-(7-8) 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Gable requires continuous bottom chord bearing. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 1, 3, 4. 6) "Semi-rigid pitchbreaks with fixed heels" Member end fixity model was used in the analysis and design of this truss. 7) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 8) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. May 21,2018 Job B18801553 Truss V14 Truss Type Valley Qty 1 Ply 1 CALA 17 CLAY Job Reference (optional) I33391329 7.640 s Aug 16 2017 MiTek Industries, Inc. Sat May 19 15:23:15 2018 Page 1 Builders First Source, mooresville,in ID:mC?hxK0VUR49rWXHgogScbzvq6P-07fMLfRGImhxMNIxd1EVVHAYnUAVSUqj4k1i7bzEulA Scale = 1:15.5 1 2 3 4 2x4 4x6 2x4 2x4 8-1-15 8-1-15 8-2-10 0-0-11 4-1-5 4-1-5 8-2-10 4-1-5 0- 0 - 4 1- 6 - 8 0- 0 - 4 4.50 12 LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2006/TPI2002 CSI. TC BC WB (Matrix) 0.36 0.12 0.05 DEFL. Vert(LL) Vert(TL) Horz(TL) in n/a n/a 0.00 (loc) - - 3 l/defl n/a n/a n/a L/d 999 999 n/a PLATES MT20 Weight: 17 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF-S Stud BOT CHORD 2x4 SPF No.2 OTHERS 2x4 SPF-S Stud BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS.(lb/size) 1=128/8-1-4, 3=128/8-1-4, 4=268/8-1-4 Max Horz 1=-12(LC 7) Max Uplift1=-18(LC 6), 3=-19(LC 7) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES-(7-8) 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Gable requires continuous bottom chord bearing. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 1, 3. 6) "Semi-rigid pitchbreaks with fixed heels" Member end fixity model was used in the analysis and design of this truss. 7) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 8) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. May 21,2018 Job B18801553 Truss V15 Truss Type Valley Qty 1 Ply 1 CALA 17 CLAY Job Reference (optional) I33391330 7.640 s Aug 16 2017 MiTek Industries, Inc. Sat May 19 15:23:16 2018 Page 1 Builders First Source, mooresville,in ID:mC?hxK0VUR49rWXHgogScbzvq6P-UJCkZ?Ru34po_Xs8Bllk2UjmguRsBxotJOmGf1zEul9 Scale = 1:12.6 1 2 3 2x4 3x4 2x4 0-0-11 0-0-11 5-11-15 5-11-4 3-0-0 3-0-0 5-11-15 3-0-0 0- 0 - 4 1- 1 - 8 0- 0 - 4 4.50 12 Plate Offsets (X,Y)-- [2:0-2-0,Edge] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2006/TPI2002 CSI. TC BC WB (Matrix) 0.16 0.43 0.00 DEFL. Vert(LL) Vert(TL) Horz(TL) in n/a n/a 0.00 (loc) - - 3 l/defl n/a n/a n/a L/d 999 999 n/a PLATES MT20 Weight: 10 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF-S Stud BOT CHORD 2x4 SPF-S Stud BRACING- TOP CHORD Structural wood sheathing directly applied or 5-11-15 oc purlins. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS.(lb/size) 1=173/5-10-10, 3=173/5-10-10 Max Horz 1=8(LC 6) Max Uplift1=-9(LC 6), 3=-9(LC 7) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES-(7-8) 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Gable requires continuous bottom chord bearing. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 1, 3. 6) "Semi-rigid pitchbreaks with fixed heels" Member end fixity model was used in the analysis and design of this truss. 7) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 8) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. May 21,2018 e d g e o f t r u s s . f r o m o u t s i d e " 1 6 / 1 - 0 P R O D U C T C O D E A P P R O V A L S J O I N T S A R E G E N E R A L L Y N U M B E R E D / L E T T E R E D C L O C K W I S E A R O U N D T H E T R U S S S T A R T I N G A T T H E J O I N T F A R T H E S T T O T H E L E F T . C H O R D S A N D W E B S A R E I D E N T I F I E D B Y E N D J O I N T N U M B E R S / L E T T E R S . W 4 - 6 W3-6 W 3 - 7 W2-7 W 1 - 7 C1-8 C 5 - 6 C 6 - 7 C 7 - 8 C4-5 C 3 - 4 C 2 - 3 C 1 - 2 TOP CHORD TOP CHORD 8 7 6 5 4 3 2 1 B O T T O M C H O R D S T O P C H O R D S B E A R I N G L A T E R A L B R A C I N G L O C A T I O N I n d i c a t e s l o c a t i o n w h e r e b e a r i n g s ( s u p p o r t s ) o c c u r . I c o n s v a r y b u t r e a c t i o n s e c t i o n i n d i c a t e s j o i n t n u m b e r w h e r e b e a r i n g s o c c u r . M i n s i z e s h o w n i s f o r c r u s h i n g o n l y . I n d i c a t e d b y s y m b o l s h o w n a n d / o r b y t e x t i n t h e b r a c i n g s e c t i o n o f t h e o u t p u t . U s e T o r I b r a c i n g i f i n d i c a t e d . T h e f i r s t d i m e n s i o n i s t h e p l a t e w i d t h m e a s u r e d p e r p e n d i c u l a r t o s l o t s . S e c o n d d i m e n s i o n i s t h e l e n g t h p a r a l l e l t o s l o t s . 4 x 4 P L A T E S I Z E T h i s s y m b o l i n d i c a t e s t h e r e q u i r e d d i r e c t i o n o f s l o t s i n c o n n e c t o r p l a t e s . " 1 6 / 1 F o r 4 x 2 o r i e n t a t i o n , l o c a t e p l a t e s 0 - C e n t e r p l a t e o n j o i n t u n l e s s x , y o f f s e t s a r e i n d i c a t e d . D i m e n s i o n s a r e i n f t - i n - s i x t e e n t h s . A p p l y p l a t e s t o b o t h s i d e s o f t r u s s a n d f u l l y e m b e d t e e t h . 1 " 4 / 3 P L A T E L O C A T I O N A N D O R I E N T A T I O N S y m b o l s N u m b e r i n g S y s t e m 1 . A d d i t i o n a l s t a b i l i t y b r a c i n g f o r t r u s s s y s t e m , e . g . d i a g o n a l o r X - b r a c i n g , i s a l w a y s r e q u i r e d . S e e B C S I . 2 . T r u s s b r a c i n g m u s t b e d e s i g n e d b y a n e n g i n e e r . F o r w i d e t r u s s s p a c i n g , i n d i v i d u a l l a t e r a l b r a c e s t h e m s e l v e s m a y r e q u i r e b r a c i n g , o r a l t e r n a t i v e T o r I b r a c i n g s h o u l d b e c o n s i d e r e d . 3 . N e v e r e x c e e d t h e d e s i g n l o a d i n g s h o w n a n d n e v e r s t a c k m a t e r i a l s o n i n a d e q u a t e l y b r a c e d t r u s s e s . 4 . P r o v i d e c o p i e s o f t h i s t r u s s d e s i g n t o t h e b u i l d i n g d e s i g n e r , e r e c t i o n s u p e r v i s o r , p r o p e r t y o w n e r a n d a l l o t h e r i n t e r e s t e d p a r t i e s . 5 . C u t m e m b e r s t o b e a r t i g h t l y a g a i n s t e a c h o t h e r . 6 . P l a c e p l a t e s o n e a c h f a c e o f t r u s s a t e a c h j o i n t a n d e m b e d f u l l y . K n o t s a n d w a n e a t j o i n t l o c a t i o n s a r e r e g u l a t e d b y A N S I / T P I 1 . 7 . D e s i g n a s s u m e s t r u s s e s w i l l b e s u i t a b l y p r o t e c t e d f r o m t h e e n v i r o n m e n t i n a c c o r d w i t h A N S I / T P I 1 . 8 . U n l e s s o t h e r w i s e n o t e d , m o i s t u r e c o n t e n t o f l u m b e r s h a l l n o t e x c e e d 1 9 % a t t i m e o f f a b r i c a t i o n . 9 . U n l e s s e x p r e s s l y n o t e d , t h i s d e s i g n i s n o t a p p l i c a b l e f o r u s e w i t h f i r e r e t a r d a n t , p r e s e r v a t i v e t r e a t e d , o r g r e e n l u m b e r . 1 0 . C a m b e r i s a n o n - s t r u c t u r a l c o n s i d e r a t i o n a n d i s t h e r e s p o n s i b i l i t y o f t r u s s f a b r i c a t o r . G e n e r a l p r a c t i c e i s t o c a m b e r f o r d e a d l o a d d e f l e c t i o n . 1 1 . P l a t e t y p e , s i z e , o r i e n t a t i o n a n d l o c a t i o n d i m e n s i o n s i n d i c a t e d a r e m i n i m u m p l a t i n g r e q u i r e m e n t s . 1 2 . L u m b e r u s e d s h a l l b e o f t h e s p e c i e s a n d s i z e , a n d i n a l l r e s p e c t s , e q u a l t o o r b e t t e r t h a n t h a t s p e c i f i e d . 1 3 . T o p c h o r d s m u s t b e s h e a t h e d o r p u r l i n s p r o v i d e d a t s p a c i n g i n d i c a t e d o n d e s i g n . 1 4 . B o t t o m c h o r d s r e q u i r e l a t e r a l b r a c i n g a t 1 0 f t . s p a c i n g , o r l e s s , i f n o c e i l i n g i s i n s t a l l e d , u n l e s s o t h e r w i s e n o t e d . 1 5 . C o n n e c t i o n s n o t s h o w n a r e t h e r e s p o n s i b i l i t y o f o t h e r s . 1 6 . D o n o t c u t o r a l t e r t r u s s m e m b e r o r p l a t e w i t h o u t p r i o r a p p r o v a l o f a n e n g i n e e r . 1 7 . I n s t a l l a n d l o a d v e r t i c a l l y u n l e s s i n d i c a t e d o t h e r w i s e . 1 8 . U s e o f g r e e n o r t r e a t e d l u m b e r m a y p o s e u n a c c e p t a b l e e n v i r o n m e n t a l , h e a l t h o r p e r f o r m a n c e r i s k s . C o n s u l t w i t h p r o j e c t e n g i n e e r b e f o r e u s e . 1 9 . R e v i e w a l l p o r t i o n s o f t h i s d e s i g n ( f r o n t , b a c k , w o r d s a n d p i c t u r e s ) b e f o r e u s e . R e v i e w i n g p i c t u r e s a l o n e i s n o t s u f f i c i e n t . 2 0 . D e s i g n a s s u m e s m a n u f a c t u r e i n a c c o r d a n c e w i t h A N S I / T P I 1 Q u a l i t y C r i t e r i a . F a i l u r e t o F o l l o w C o u l d C a u s e P r o p e r t y D a m a g e o r P e r s o n a l I n j u r y G e n e r a l S a f e t y N o t e s * P l a t e l o c a t i o n d e t a i l s a v a i l a b l e i n M i T e k 2 0 / 2 0 s o f t w a r e o r u p o n r e q u e s t . I n d u s t r y S t a n d a r d s : 6 - 4 - 8 d i m e n s i o n s s h o w n i n f t - i n - s i x t e e n t h s ( D r a w i n g s n o t t o s c a l e ) © 2 0 1 2 M i T e k ® A l l R i g h t s R e s e r v e d M i T e k E n g i n e e r i n g R e f e r e n c e S h e e t : M I I - 7 4 7 3 r e v . 1 0 / 0 3 / 2 0 1 5 W E B S e d g e o f t r u s s . f r o m o u t s i d e " 1 6 / 1 - 0 I C C - E S R e p o r t s : E S R - 1 3 1 1 , E S R - 1 3 5 2 , E S R 1 9 8 8 E R - 3 9 0 7 , E S R - 2 3 6 2 , E S R - 1 3 9 7 , E S R - 3 2 8 2 J O I N T S A R E G E N E R A L L Y N U M B E R E D / L E T T E R E D C L O C K W I S E A R O U N D T H E T R U S S S T A R T I N G A T T H E J O I N T F A R T H E S T T O T H E L E F T . C H O R D S A N D W E B S A R E I D E N T I F I E D B Y E N D J O I N T N U M B E R S / L E T T E R S . W 4 - 6 W3-6 W 3 - 7 W2-7 W 1 - 7 C1-8 C 5 - 6 C 6 - 7 C 7 - 8 C4-5 C 3 - 4 C 2 - 3 C 1 - 2 TOP CHORD TOP CHORD 8 7 6 5 4 3 2 1 B O T T O M C H O R D S T O P C H O R D S B E A R I N G I n d i c a t e s l o c a t i o n w h e r e b e a r i n g s ( s u p p o r t s ) o c c u r . I c o n s v a r y b u t r e a c t i o n s e c t i o n i n d i c a t e s j o i n t n u m b e r w h e r e b e a r i n g s o c c u r . 4 x 4 P L A T E S I Z E T h i s s y m b o l i n d i c a t e s t h e r e q u i r e d d i r e c t i o n o f s l o t s i n c o n n e c t o r p l a t e s . " 1 6 / 1 F o r 4 x 2 o r i e n t a t i o n , l o c a t e p l a t e s 0 - 1 " 4 / 3 P L A T E L O C A T I O N A N D O R I E N T A T I O N S y m b o l s N u m b e r i n g S y s t e m G e n e r a l S a f e t y N o t e s * P l a t e l o c a t i o n d e t a i l s a v a i l a b l e i n M i T e k 2 0 / 2 0 s o f t w a r e o r u p o n r e q u e s t . I n d u s t r y S t a n d a r d s : A N S I / T P I 1 : N a t i o n a l D e s i g n S p e c i f i c a t i o n f o r M e t a l P l a t e C o n n e c t e d W o o d T r u s s C o n s t r u c t i o n . D S B - 8 9 : D e s i g n S t a n d a r d f o r B r a c i n g . B C S I : B u i l d i n g C o m p o n e n t S a f e t y I n f o r m a t i o n , G u i d e t o G o o d P r a c t i c e f o r H a n d l i n g , I n s t a l l i n g & B r a c i n g o f M e t a l P l a t e C o n n e c t e d W o o d T r u s s e s . 6 - 4 - 8 d i m e n s i o n s s h o w n i n f t - i n - s i x t e e n t h s W E B S T r u s s e s a r e d e s i g n e d f o r w i n d l o a d s i n t h e p l a n e o f t h e t r u s s u n l e s s o t h e r w i s e s h o w n . L u m b e r d e s i g n v a l u e s a r e i n a c c o r d a n c e w i t h A N S I / T P I 1 s e c t i o n 6 . 3 T h e s e t r u s s d e s i g n s r e l y o n l u m b e r v a l u e s e s t a b l i s h e d b y o t h e r s .