Interior Lighting Compliance Certificate
Project Title:
90.1 (2007) Standard
Project Type: Alteration
Construction Site:
435 106th Street
Suite 750
Carmel, IN 46032
Owner/Agent:
Jason Upton
Jalofit LLC DBA F45 West Carmel
4331 Cherry Lane
Zionsville, IN 46077
317.442.3245
westcarmel@f45training.com
Designer/Contractor:
Glenn Gareis
GMG Architects LLC
484 E Carmel Drive
#377
Carmel, IN 46032
317.694.0785
glenn@GMGArchitects.com
Project Information
Energy Code:
F45 West Carmel Fitness Center
Allowed Interior Lighting Power
A
Area Category
B
Floor Area
(ft2)
C
Allowed
Watts / ft2
D
Allowed Watts
(B X C)
1-Fitness Area (Gymnasium/Exercise Center:Exercise Area) 1815 0.90 1634
2-Hall (Common Space Types:Corridor/Transition) 91 0.50 46
3-Storage #1 (Common Space Types:Active Storage) 62 0.80 50
4-Storage #2 (Common Space Types:Active Storage) 71 0.80 57
5-Bathroom #1 (Common Space Types:Restrooms) 47 0.90 42
6-Bathroom #2 (Common Space Types:Restrooms) 47 0.90 42
7-Shower #1 (Common Space Types:Dressing/Locker/Fitting Room) 72 0.60 43
8-Shower #2 (Common Space Types:Dressing/Locker/Fitting Room) 72 0.60 43
Total Allowed Watts = 1956
Proposed Interior Lighting Power
E
(C X D)
D
Fixture
Watt.
A
Fixture ID : Description / Lamp / Wattage Per Lamp / Ballast
B
Lamps/
Fixture
C
E
(C X D)
D
Fixture
Watt.
A
Fixture ID : Description / Lamp / Wattage Per Lamp / Ballast
B
Lamps/
Fixture
C
# of
Fixtures
LED 6 Vanity: Vanity Light: LED A Lamp 9W: 2 1 18 18
LED 5 Wet Area: Wet Area Light: LED PAR 11W: 1 1 9 9
Shower #1 ( Common Space Types:Dressing/Locker/Fitting Room 72 sq.ft.)
LED 4 Fan/Light: Fan/Light: LED A Lamp 7W: 1 1 7 7
LED 6 Vanity: Vanity Light: LED A Lamp 9W: 2 1 18 18
LED 5 Wet Area: Wet Area Light: LED PAR 11W: 1 2 9 18
Shower #2 ( Common Space Types:Dressing/Locker/Fitting Room 72 sq.ft.)
LED 4 Fan/Light: Fan/Light: LED A Lamp 7W: 1 1 7 7
LED 6 Vanity: Vanity Light: LED A Lamp 9W: 2 1 18 18
LED 5 Wet Area: Wet Area Light: LED PAR 11W: 1 2 9 18
Total Proposed Watts = 1895
Interior Lighting Compliance Statement
Compliance Statement: The proposed interior lighting alteration project represented in this document is consistent with the
building plans, specifications, and other calculations submitted with this permit application. The proposed interior lighting
systems have been designed to meet the 90.1 (2007) Standard requirements in COMcheck Version 4.0.8.2 and to comply with
any applicable mandatory requirements listed in the Inspection Checklist.
Name - Title Signature Date
Interior Lighting PASSES
Project Title:
Data filename:
F45 West Carmel Fitness Center
C:\Users\Glenn Gareis\Documents\0_GMG Architects LLC\Projects\2018.09 - (Upton) F45 Fitness
Studio\3 - Permit Set\COM Check\(Upton) F45 Carmel COMCheck.cck
Report date: 05/30/18
Page 2 of 6
Inspection Checklist
Requirements: 100.0% were addressed directly in the COMcheck software
COMcheck Software Version 4.0.8.2
Text in the "Comments/Assumptions" column is provided by the user in the COMcheck Requirements screen. For each
requirement, the user certifies that a code requirement will be met and how that is documented, or that an exception
is being claimed. Where compliance is itemized in a separate table, a reference to that table is provided.
Energy Code: 90.1 (2007) Standard
Section
#
& Req.ID
Plan Review Complies? Comments/Assumptions
4.2.2
[PR4]1
Plans, specifications, and/or
calculations provide all information
with which compliance can be
determined for the lighting and
electrical systems and equipment and
document where exceptions to the
standard are claimed. Information
provided should include interior
lighting power calculations, wattage of
bulbs and ballasts, transformers and
control devices.
Complies
Does Not
Not Observable
Not Applicable
Requirement will be met.
8.4.1.1,
8.4.1.2
[PR6]2
Plans, specifications, and/or
calculations provide all information
with which compliance can be
determined for the electrical systems
and equipment and document where
exceptions are claimed. Feeder
connectors sized in accordance with
approved plans and branch circuits
sized for maximum drop of 3%.
Complies
Does Not
Not Observable
Not Applicable
Requirement will be met.
Additional Comments/Assumptions:
1 High Impact (Tier 1) 2 Medium Impact (Tier 2) 3 Low Impact (Tier 3)
Project Title:
Data filename:
F45 West Carmel Fitness Center
C:\Users\Glenn Gareis\Documents\0_GMG Architects LLC\Projects\2018.09 - (Upton) F45 Fitness
Studio\3 - Permit Set\COM Check\(Upton) F45 Carmel COMCheck.cck
Report date: 05/30/18
Page 3 of 6
Section
#
& Req.ID
Rough-In Electrical Inspection Complies? Comments/Assumptions
9.4.1.1
[EL1]2
Automatic controls to shut off all
building lighting installed in buildings
>5,000 ft2.
Complies
Does Not
Not Observable
Not Applicable
Requirement will be met.
9.4.1.2
[EL2]2
Independent lighting controls installed
per approved lighting plans and all
manual controls readily accessible and
visible to occupants.
Complies
Does Not
Not Observable
Not Applicable
Requirement will be met.
9.4.1.4
[EL4]1
Separate lighting control devices for
specific uses installed per approved
lighting plans.
Complies
Does Not
Not Observable
Not Applicable
Requirement will be met.
9.4.2
[EL5]3
Ballasted one and three lamp fixtures
with >30 W/lamp have two lamp
tandem wired ballasts when >=2
fixtures in same space on same
control.
Complies
Does Not
Not Observable
Not Applicable
Requirement will be met.
9.4.3
[EL6]1
Exit signs do not exceed 5 watts per
face.
Complies
Does Not
Not Observable
Not Applicable
Requirement will be met.
9.6.2
[EL8]1
Additional interior lighting power
allowed for special functions per the
Section
#
& Req.ID
Final Inspection Complies? Comments/Assumptions
8.7.1
[FI16]3
Furnished as-built drawings for
electric power systems within 30 days
of system acceptance.
Complies
Does Not
Not Observable
Not Applicable
Requirement will be met.
8.7.2
[FI17]3
Furnished O&M instructions for
systems and equipment to the
building owner or designated
representative.
Complies
Does Not
Not Observable
Not Applicable
Requirement will be met.
9.2.2.3
[FI18]1
Interior installed lamp and fixture
lighting power is consistent with what
is shown on the approved lighting
plans, demonstrating proposed watts
are less than or equal to allowed
watts.
Complies
Does Not
Not Observable
Not Applicable
See the Interior Lighting fixture schedule for values.
Additional Comments/Assumptions:
1 High Impact (Tier 1) 2 Medium Impact (Tier 2) 3 Low Impact (Tier 3)
Project Title:
Data filename:
F45 West Carmel Fitness Center
C:\Users\Glenn Gareis\Documents\0_GMG Architects LLC\Projects\2018.09 - (Upton) F45 Fitness
Studio\3 - Permit Set\COM Check\(Upton) F45 Carmel COMCheck.cck
Report date: 05/30/18
Page 5 of 6
Project Title:
Data filename:
F45 West Carmel Fitness Center
C:\Users\Glenn Gareis\Documents\0_GMG Architects LLC\Projects\2018.09 - (Upton) F45 Fitness
Studio\3 - Permit Set\COM Check\(Upton) F45 Carmel COMCheck.cck
Report date: 05/30/18
Page 6 of 6
approved lighting plans and is
automatically controlled and
separated from general lighting.
Complies
Does Not
Not Observable
Not Applicable
Requirement will be met.
Additional Comments/Assumptions:
1 High Impact (Tier 1) 2 Medium Impact (Tier 2) 3 Low Impact (Tier 3)
Project Title:
Data filename:
F45 West Carmel Fitness Center
C:\Users\Glenn Gareis\Documents\0_GMG Architects LLC\Projects\2018.09 - (Upton) F45 Fitness
Studio\3 - Permit Set\COM Check\(Upton) F45 Carmel COMCheck.cck
Report date: 05/30/18
Page 4 of 6
# of
Fixtures
Fitness Area ( Gymnasium/Exercise Center:Exercise Area 1815 sq.ft.)
LED 1 High Bay: 2x4 High Bay: LED Other Fixture Unit 125W: 1 10 162 1620
Hall ( Common Space Types:Corridor/Transition 91 sq.ft.)
LED 5 Wet Area: Wet Area Light: LED PAR 11W: 1 5 9 45
Storage #1 ( Common Space Types:Active Storage 62 sq.ft.)
LED 2 2x2 Lay In: 2x4 Lay-In: LED Panel 54W: 1 1 50 50
Storage #2 ( Common Space Types:Active Storage 71 sq.ft.)
LED 3 2x4 Lay In: 2x2 Lay-In: LED Panel 40W: 1 1 40 40
Bathroom #1 ( Common Space Types:Restrooms 47 sq.ft.)
LED 6 Vanity: Vanity Light: LED A Lamp 9W: 2 1 18 18
LED 5 Wet Area: Wet Area Light: LED PAR 11W: 1 1 9 9
Bathroom #2 ( Common Space Types:Restrooms 47 sq.ft.)
Project Title:
Data filename:
F45 West Carmel Fitness Center
C:\Users\Glenn Gareis\Documents\0_GMG Architects LLC\Projects\2018.09 - (Upton) F45 Fitness
Studio\3 - Permit Set\COM Check\(Upton) F45 Carmel COMCheck.cck
Report date: 05/30/18