Loading...
HomeMy WebLinkAboutCOMPLIANCE REPORT - LIGHTINGCOMcheck Software Version 4.0.8.2 Interior Lighting Compliance Certificate Project Title: 90.1 (2007) Standard Project Type: Alteration Construction Site: 435 106th Street Suite 750 Carmel, IN 46032 Owner/Agent: Jason Upton Jalofit LLC DBA F45 West Carmel 4331 Cherry Lane Zionsville, IN 46077 317.442.3245 westcarmel@f45training.com Designer/Contractor: Glenn Gareis GMG Architects LLC 484 E Carmel Drive #377 Carmel, IN 46032 317.694.0785 glenn@GMGArchitects.com Project Information Energy Code: F45 West Carmel Fitness Center Allowed Interior Lighting Power A Area Category B Floor Area (ft2) C Allowed Watts / ft2 D Allowed Watts (B X C) 1-Fitness Area (Gymnasium/Exercise Center:Exercise Area) 1815 0.90 1634 2-Hall (Common Space Types:Corridor/Transition) 91 0.50 46 3-Storage #1 (Common Space Types:Active Storage) 62 0.80 50 4-Storage #2 (Common Space Types:Active Storage) 71 0.80 57 5-Bathroom #1 (Common Space Types:Restrooms) 47 0.90 42 6-Bathroom #2 (Common Space Types:Restrooms) 47 0.90 42 7-Shower #1 (Common Space Types:Dressing/Locker/Fitting Room) 72 0.60 43 8-Shower #2 (Common Space Types:Dressing/Locker/Fitting Room) 72 0.60 43 Total Allowed Watts = 1956 Proposed Interior Lighting Power E (C X D) D Fixture Watt. A Fixture ID : Description / Lamp / Wattage Per Lamp / Ballast B Lamps/ Fixture C E (C X D) D Fixture Watt. A Fixture ID : Description / Lamp / Wattage Per Lamp / Ballast B Lamps/ Fixture C # of Fixtures LED 6 Vanity: Vanity Light: LED A Lamp 9W: 2 1 18 18 LED 5 Wet Area: Wet Area Light: LED PAR 11W: 1 1 9 9 Shower #1 ( Common Space Types:Dressing/Locker/Fitting Room 72 sq.ft.) LED 4 Fan/Light: Fan/Light: LED A Lamp 7W: 1 1 7 7 LED 6 Vanity: Vanity Light: LED A Lamp 9W: 2 1 18 18 LED 5 Wet Area: Wet Area Light: LED PAR 11W: 1 2 9 18 Shower #2 ( Common Space Types:Dressing/Locker/Fitting Room 72 sq.ft.) LED 4 Fan/Light: Fan/Light: LED A Lamp 7W: 1 1 7 7 LED 6 Vanity: Vanity Light: LED A Lamp 9W: 2 1 18 18 LED 5 Wet Area: Wet Area Light: LED PAR 11W: 1 2 9 18 Total Proposed Watts = 1895 Interior Lighting Compliance Statement Compliance Statement: The proposed interior lighting alteration project represented in this document is consistent with the building plans, specifications, and other calculations submitted with this permit application. The proposed interior lighting systems have been designed to meet the 90.1 (2007) Standard requirements in COMcheck Version 4.0.8.2 and to comply with any applicable mandatory requirements listed in the Inspection Checklist. Name - Title Signature Date Interior Lighting PASSES Project Title: Data filename: F45 West Carmel Fitness Center C:\Users\Glenn Gareis\Documents\0_GMG Architects LLC\Projects\2018.09 - (Upton) F45 Fitness Studio\3 - Permit Set\COM Check\(Upton) F45 Carmel COMCheck.cck Report date: 05/30/18 Page 2 of 6 Inspection Checklist Requirements: 100.0% were addressed directly in the COMcheck software COMcheck Software Version 4.0.8.2 Text in the "Comments/Assumptions" column is provided by the user in the COMcheck Requirements screen. For each requirement, the user certifies that a code requirement will be met and how that is documented, or that an exception is being claimed. Where compliance is itemized in a separate table, a reference to that table is provided. Energy Code: 90.1 (2007) Standard Section # & Req.ID Plan Review Complies? Comments/Assumptions 4.2.2 [PR4]1 Plans, specifications, and/or calculations provide all information with which compliance can be determined for the lighting and electrical systems and equipment and document where exceptions to the standard are claimed. Information provided should include interior lighting power calculations, wattage of bulbs and ballasts, transformers and control devices. Complies Does Not Not Observable Not Applicable Requirement will be met. 8.4.1.1, 8.4.1.2 [PR6]2 Plans, specifications, and/or calculations provide all information with which compliance can be determined for the electrical systems and equipment and document where exceptions are claimed. Feeder connectors sized in accordance with approved plans and branch circuits sized for maximum drop of 3%. Complies Does Not Not Observable Not Applicable Requirement will be met. Additional Comments/Assumptions: 1 High Impact (Tier 1) 2 Medium Impact (Tier 2) 3 Low Impact (Tier 3) Project Title: Data filename: F45 West Carmel Fitness Center C:\Users\Glenn Gareis\Documents\0_GMG Architects LLC\Projects\2018.09 - (Upton) F45 Fitness Studio\3 - Permit Set\COM Check\(Upton) F45 Carmel COMCheck.cck Report date: 05/30/18 Page 3 of 6 Section # & Req.ID Rough-In Electrical Inspection Complies? Comments/Assumptions 9.4.1.1 [EL1]2 Automatic controls to shut off all building lighting installed in buildings >5,000 ft2. Complies Does Not Not Observable Not Applicable Requirement will be met. 9.4.1.2 [EL2]2 Independent lighting controls installed per approved lighting plans and all manual controls readily accessible and visible to occupants. Complies Does Not Not Observable Not Applicable Requirement will be met. 9.4.1.4 [EL4]1 Separate lighting control devices for specific uses installed per approved lighting plans. Complies Does Not Not Observable Not Applicable Requirement will be met. 9.4.2 [EL5]3 Ballasted one and three lamp fixtures with >30 W/lamp have two lamp tandem wired ballasts when >=2 fixtures in same space on same control. Complies Does Not Not Observable Not Applicable Requirement will be met. 9.4.3 [EL6]1 Exit signs do not exceed 5 watts per face. Complies Does Not Not Observable Not Applicable Requirement will be met. 9.6.2 [EL8]1 Additional interior lighting power allowed for special functions per the Section # & Req.ID Final Inspection Complies? Comments/Assumptions 8.7.1 [FI16]3 Furnished as-built drawings for electric power systems within 30 days of system acceptance. Complies Does Not Not Observable Not Applicable Requirement will be met. 8.7.2 [FI17]3 Furnished O&M instructions for systems and equipment to the building owner or designated representative. Complies Does Not Not Observable Not Applicable Requirement will be met. 9.2.2.3 [FI18]1 Interior installed lamp and fixture lighting power is consistent with what is shown on the approved lighting plans, demonstrating proposed watts are less than or equal to allowed watts. Complies Does Not Not Observable Not Applicable See the Interior Lighting fixture schedule for values. Additional Comments/Assumptions: 1 High Impact (Tier 1) 2 Medium Impact (Tier 2) 3 Low Impact (Tier 3) Project Title: Data filename: F45 West Carmel Fitness Center C:\Users\Glenn Gareis\Documents\0_GMG Architects LLC\Projects\2018.09 - (Upton) F45 Fitness Studio\3 - Permit Set\COM Check\(Upton) F45 Carmel COMCheck.cck Report date: 05/30/18 Page 5 of 6 Project Title: Data filename: F45 West Carmel Fitness Center C:\Users\Glenn Gareis\Documents\0_GMG Architects LLC\Projects\2018.09 - (Upton) F45 Fitness Studio\3 - Permit Set\COM Check\(Upton) F45 Carmel COMCheck.cck Report date: 05/30/18 Page 6 of 6 approved lighting plans and is automatically controlled and separated from general lighting. Complies Does Not Not Observable Not Applicable Requirement will be met. Additional Comments/Assumptions: 1 High Impact (Tier 1) 2 Medium Impact (Tier 2) 3 Low Impact (Tier 3) Project Title: Data filename: F45 West Carmel Fitness Center C:\Users\Glenn Gareis\Documents\0_GMG Architects LLC\Projects\2018.09 - (Upton) F45 Fitness Studio\3 - Permit Set\COM Check\(Upton) F45 Carmel COMCheck.cck Report date: 05/30/18 Page 4 of 6 # of Fixtures Fitness Area ( Gymnasium/Exercise Center:Exercise Area 1815 sq.ft.) LED 1 High Bay: 2x4 High Bay: LED Other Fixture Unit 125W: 1 10 162 1620 Hall ( Common Space Types:Corridor/Transition 91 sq.ft.) LED 5 Wet Area: Wet Area Light: LED PAR 11W: 1 5 9 45 Storage #1 ( Common Space Types:Active Storage 62 sq.ft.) LED 2 2x2 Lay In: 2x4 Lay-In: LED Panel 54W: 1 1 50 50 Storage #2 ( Common Space Types:Active Storage 71 sq.ft.) LED 3 2x4 Lay In: 2x2 Lay-In: LED Panel 40W: 1 1 40 40 Bathroom #1 ( Common Space Types:Restrooms 47 sq.ft.) LED 6 Vanity: Vanity Light: LED A Lamp 9W: 2 1 18 18 LED 5 Wet Area: Wet Area Light: LED PAR 11W: 1 1 9 9 Bathroom #2 ( Common Space Types:Restrooms 47 sq.ft.) Project Title: Data filename: F45 West Carmel Fitness Center C:\Users\Glenn Gareis\Documents\0_GMG Architects LLC\Projects\2018.09 - (Upton) F45 Fitness Studio\3 - Permit Set\COM Check\(Upton) F45 Carmel COMCheck.cck Report date: 05/30/18 Page 1 of 6