HomeMy WebLinkAbout10Q Q.5 R R.5 GENERAL CONSTRUCTION NOTES: 1. DIMENSIONS ARE FROM STUD TO STUD UNLESS NOTED OR SHOWN OTHERWISE. ANY 20 DIMENSION NOT SHOWN OR DEEMED QUESTIONABLE ARE TO BE VERIFIED BY ARCHITECT DO FRAME NOT SCALE DRAWINGS. 2. SEE CONSTRUCTION PLAN LEGEND FOR WALL CONSTRUCTION AND WALL TYPES. ALL WALLS ww 0LLJ Of ARE TO BE W3 UNLESS NOTED OTHERWISE. WALLS AT COLUMN WRAPS TO BE W1 UNLESS SIZE NOTED OTHERWISE. 3. ALL WALLS SHALL BE CHALKED OFF FOR ARCHITECT'S REVIEW OF NEW WALL CONSTRUCTION. 4. PROVIDE CONCEALED FIRE RATED WOOD BLOCKING SUPPORTS AS REQUIRED FOR ALL �' co wQ -Q CM > x U) 0 _1 UO a¢. _J o 0 _J ac c �aUcna0w SURFACE MOUNTED ITEMS. 5. NEW DOOR AND FRAME NUMBERS CORRESPOND TO ROOM NUMBERS. WHERE MORE THAN Y F- ONE DOOR OCCURS IN A ROOM, A SUFFIX HAS BEEN ADDED (ie. 100A). 6. ALL NEW DOORS TO BE INSTALLED WITH HINGE 6"AWAY FROM WALL UNLESS NOTED T-0" OTHERWISE. 7. ALL NEW DOORS SHALLALLOW 12" CLEAR ON PUSH SIDE AND 18" CLEAR ON PULL SIDE OF HM DOOR, UNLESS NOTED OTHERWISE, TO MEET CURRENTADA CODE REGULATIONS. Construction Plan C(`AI l=• 11d" = 1'-!1" DOOR SCHEDULE 3-518" 20 GAUGE METAL STUDS @16"O.C.CD DOOR FRAME HARDWARE REMARKS Z co Z LU 0:z ww 0LLJ Of LU SIZE w W 2 Q w E W Q ] LUV) �' co wQ -Q CM > x U) 0 _1 UO a¢. _J o 0 _J ac c �aUcna0w C _ = U, _ Y F- 101 CLOSET (2)2'-6" T-0" 13/4" WOOD D3 HM D3 DM,RC,S HINGE STOPS 102 OFFICE T-0" T-0" 1314" WD/GL D2 HM D2 L,S �U 103 OFFICE T-0" T-0" 13/4" WD/GL D2 HM D2 L,S 104 OFFICE T-0" T-0" 13/4" WD/GL D2 HM D2 L,S 106 IT/STORAGE T-0" T-0° 1314" WOOD D1 HM D1 L,S 109 RESTROOM T-0" T-0" 1314" WOOD D1 HM D1 PR,S,CL 110 RESTROOM T-0" T-0" 1314" WOOD D1 HM D1 PR,S,CL 111 MECHANICAL T-0" T-0" 13/4" WOOD D1 HM D1 PS,S HINGE STOP 112 OFFICE T-0" T-0" 13/4" WD/GL D2 HM D2 L,S 113 OFFICE T-0" T-0" 13/4" WD/GL D2 HM D2 L,S 113A CLOSET T-0" T-0" 13/4" WOOD D1 HM D1 PS,S FLOOR STOP 114 CONFERENCE T-0" T-0" 13/4" WD/GL D2 HM D2 PS,S 114A CONFERENCE T-0" T-0" 13/4" WOOD D1 HM D1 PS,S 115 OFFICE T-0" T-0" 13/4" WD/GL D2 HM D2 L,S 116 OFFICE T-0" T-0" 13/4" WD/GL D2 HM D2 L,S 117 OFFICE T-0" T-0° 13/4" WD/GL D2 HM D2 L,S DOOR SCHEDULE NOTES: 1. ALL DOORS TO BE PAINTED P2 UNLESS NOTED OTHERWISE. 2. ALL HOLLOW METAL DOOR FRAMES TO PAINTED P2. 3. ALL EXISTING HOLLOW METAL DOORS AND DOOR FRAMES TO BE PAINTED TO MATCH ADJACENT WALL FINISH UNLESS NOTED OTHERWISE. 4. CONTRACTOR TO VERIFY DOOR HEIGHT PRIOR TO CONSTRUCTION. 5. HARDWARE TO BE SCHLAGE, AL SERIES, JUPITER STYLE, 626 FINISH LEVER HARDWARE. 6. CLOSERS TO HAVE HOLD OPEN OPTION. 7. COORDINATE KEYING LOCKSETS WITH TENANT. KI D2 j D3 8. ALL NEW FIRE EXTINGUISHER CABINETS TO BE FINISHED TO MATCH ADJACENT WALL FINISH AND INSTALLED ACCORDING TO CODE. LIFESAFETY CONTRACTOR TO VERIFY PLACEMENT AND COUNT OF FIRE EXTINGUISHERS THROUGHOUT THE SPACE. IF ADDITIONAL FIRE EXTINGUISHER LOCATIONS ARE NEEDED, A PLAN MUST BE SUBMITTED TO THE ARCHITECT FOR REVIEW FOR AESTHETIC PURPOSES ONLY. 9. RADIUS ALL OUTSIDE CORNERS OF COUNTER TOPS. SIZE OF RADIUS TO BE VERIFIED WITH ARCHITECT. 10. APPLY SEALANT ATALL PLUMBING FIXTURES, AT JUNCTURE WITH WALLAND ATALL COUNTERTOPS AND BACKSPLASH JUNCTURES. 11. FLOOR SHALL BE CLEANED, SMOOTH AND LEVEL FOR INSTALLATION OF NEW FLOOR FINISHES AS SCHEDULED. 12. ALL WALLS SCHEDULED TO REMAIN (I.E. CORE WALLS, AND DEMISING WALLS) SHALL BE PATCHED, REPAIRED, AND SANDED SMOOTH IN PREPARATION FOR NEW FINISHES. 13. USE MOISTURE -MOLD RESISTANT GYPSUM WALLBOARD MEETING ASTM D3273 ON ALL WALLS IN RESTROOMS. 14. ALL PENETRATIONS IN RATED WALL PARTITIONS AND FLOOR SYSTEMS SHALL BE FIRE RATED ASSEMBLIES. SUBMIT PRODUCT DATAAND ASSEMBLY DRAWINGS WITH TEST FILE NUMBERS FOR REVIEW. 15. INSULATION FOR INTERIOR WALL APPLICATIONS SHALL BE FORMALDEHYDE -FREE, UNFACED, GLASS -FIBER BLANKET INSULATION IN BATT FORM CONFORMING TO ASTM C 665, TYPE I, WITH THICKNESS TO BE EQUAL OR GREATER THAN THE STUD THICKNESS OF THE WALL INTO WHICH IS IT INSTALLED. 16. REPAIR AND PATCH ALL FIRE PROOFING ON THE BUILDING SHELL THAT WAS REMOVED DURING CONSTRUCTION. REMOVE FIREPROOFING SPRAY FROM THE DECKAND OTHER ITEMS THAT DO NOT REQUIRE FIRE PROOFING. 17, ALL NEW WORKSURFACES TO RECEIVE 3" GROMMETS. NEW GROMMET LOCATIONS TO BE VERIFIED WITH TENANT IN THE FIELD AND WITH RESPECT TO NEW ELECTRICAL LAYOUT. GROMMET COLOR TO BE BLACK. WALL LEGEND: NOTES: EXISTING PARTITION TO REMAIN NEW WALL PARTITION ® NEW LOW WALL PARTITION W1 7/8" METAL FURRING EXISTING WALL WITH 5/8" GYPSUM WALL BOARD ONE SIDE. WALLS TO EXTEND TO 6" ABOVE FINISHED CEILING. W2 3-5/8" 20 GAUGE METAL STUDS @16" O.C. WITH 5/8" GYPSUM WALL BOARD ONE SIDE. WALLS TO EXTEND TO 6" ABOVE FINISHED CEILING. CONSTRUCTION PLAN NOTES: FP1 ALIGN FINISHED FACES. FP2 NEW SEMI RECESSED FIRE EXTINGUISHER CABINET TO BE INSTALLED IN WALLAT THESE LOCATIONS WITH TOP OF CABINETAT 54" AFF. PAINT TO MATCH ADJACENT WALL SURFACE. CONFIRM QUANTITY OF EXTINGUISHERS WITH FIRE DEPARTMENT. IF EXTINGUISHERS NEED TO BE ADDED VERIFY LOCATIONS WITH THE ARCHITECT. FP3 EXISTING WALLS TO BE LEFT UNFINISHED. FP4 PROVIDE ONE LAYER OF DRYWALLAT EXISTING STOREFRONT LOCATIONS. FP5 COFFEE MAKER PROVIDED AND INSTALLED BY TENANT. G.C. TO PROVIDE WATER & POWER SOURCE FOR COFFEE MAKER. VERIFY REQUIREMENTS WITH MANUFACTURER'S MANUAL. FP6 MICROWAVE PROVIDED AND INSTALLED BY TENANT. G.C. TO PROVIDE POWER SOURCE FOR MICROWAVE. VERIFY ELECTRICAL REQUIREMENTS WITH MANUFACTURER'S MANUAL. FP7 REFRIGERATOR PROVIDED AND INSTALLED BY TENANT. G.C. TO PROVIDE WATER & POWER SOURCE FOR REFRIGERATOR. VERIFY REQUIREMENTS WITH MANUFACTURER'S MANUAL. FPS COPIER PROVIDED AND INSTALLED BY TENANT. G.C. TO PROVIDE POWER SOURCE FOR COPIER. VERIFY ELECTRICAL REQUIREMENTS WITH MANUFACTURER'S MANUAL. FP9 PROVIDE & INSTALL COMMERCIAL WATER HEATER FOR (2) RESTROOMS AND THE BAR SINK. Fp�Q PROVIDE 42" UPPER CABINETS TO BE: SMART, SHEFFIELD, MAPLE COFFEE. PULLS TO BE MOCKETT, DP55E-SSS. SEE ELEVATION 1/A4.1. PROVIDE 36" UPPER CABINETS, MICROWAVE CABINET, AND BASE CABINETS TO BE: SMART, SHEFFIELD, MAPLE COFFEE. PLASTIC LAMINATE COUNTER WITH 1-112" LIP AND 4" BACK SPLASH. PULLS TO BE MOCKETT, DP55B-SSS. INCLUDE PLUMBING FOR BAR SINK TO BE: STERLING, MIDDLETON 14631 -3 -NAW/ KOHLER, CORALAIS K -15160 -CP. SEE ELEVATION 2/A4.1. FP12 PROVIDE & INSTALL FLOOR DRAIN WITH STRAINER. COORDINATE WITH MEP CONSULTANTS. P1 PROVIDE BUILT-IN STAINED WOOD RECEPTION DESK WITH FROSTED GLASS TRANSACTION TOP ON STAND-OFFS, PLASTIC LAMINATE WORK SURFACE, AND TWO (2) PEDESTAL STORAGE UNITS. SEE DETAILS 1/A4.3. P1 PROVIDE CHROME COAT RODAND PAINTED WOOD SHELF. SEE DETAIL 7/A4.1. P1 PROVIDE 314"x4'x4' FIRE RETARDANT PLYWOOD PHONE BOARD MOUNTEDAT 60"A.F.F. PHONE BOARD TO BE PAINTED WITH FIRE RETARDANT PAINT, COLOR OF PAINT TO MATCH ADJACENT WALL FINISH. P1 PROVIDE WATER METER TO MONITOR WATER SUPPLY. P1 PROVIDE PLYWOOD BLOCKING FOR TENANT PROVIDED AND INSTALLED TV P1 ALIGN WALL WITH WINDOW MULLION AS PER BUILDING STANDARD DETAILS. SEE DETAIL 8/A4.1. FPt9 PROVIDE EXPANSION JOINT COVERS TO BE: C/S GROUP, FWF-200AND FWFC-200 WALL EXPANSION JOINT COVERS OR EQUAL. SEE SHEETA3.1 FOR DETAILS. 9 PROVIDE EXTERIOR SIGNAGE. SEE DETAILS ON SHEETA4.4. 9 PROVIDE BLOCKING FOR INSTALLATION OF WOOD BASE. 9 PROVIDE BLOCKING FOR INSTALLATION OF CROWN MOULDING. FP23 WALL TO BE 1 -HOUR FIRE RATED. PROVIDE FLUSH ACCESS PANELAS REQUIRED FOR ICE MELT SENSOR. FP24 PROVIDE MANUAL ROLLER SHADES TO BE: SHEER WEAVE, STYLE 2000, Q10 BRONZE. VERIFY MOUNTING CONDITION IN THE FIELD. CONTACT BILL SWHEAR, 317-335-3100. 8 NEW WALL TO COVER CHANGE IN EXISTING FOUNDATION HEIGHT. 9 RELOCATE SOLENOID CONTROL TO ACCESSIBLE AREAABOVE CEILING. 9 RELOCATE CONDENSATE DRAIN PIPES TO RUN WITHIN ADJACENT COLUMN WRAP. FPZa PROVIDE FLUSH ACCESS PANELAS REQUIRED AT OPEN DRAIN. 9 RELOCATE PIPE HEATER CONTROLLER ABOVE ACCESSIBLE CEILING. FP30 PROVIDE (1) LAYER OF PLYWOOD BEHIND DRYWALL FROM FLOOR TO CEILING FOR TENANT PROVIDED FULL LENGTH TV SCREEN. 9 REMOVE HANDLES FROM EXTERIOR SIDE OF DOORS AND SAVE FOR REUSE. CAP AS NEEDED. W3 3-518" 20 GAUGE METAL STUDS @16"O.C.CD — WITH 5/8" GYPSUM WALL BOARD EACH SIDE. z M LU WALLS TO EXTEND TO STRUCTURAL DECKABOVE. G PROVIDE 3-5/8" INSULATION INSIDE WALL. W4 3-5/8" 25 GAUGE METAL STUDS @16"O.C. C — WITH 5/8" GYPSUM WALL BOARD EACH SIDE. LU WALLS TO EXTEND TO 6"ABOVE FINISHED CEILING. L W5 1 1/2" 20 GAUGE METAL STUDS @16" O.C. U — WITH 5/8" GYPSUM WALL BOARD ONE SIDE. WALLS TO EXTEND TO THE STRUCTURAL DECK. W6 3-5/8" 20 GAUGE METAL STUDS @16"O.C. — WITH 5/8" GYPSUM WALL BOARD EACH SIDE. WALLS TO EXTEND TO STRUCTURAL DECKABOVE. DENOTES AREA NOT IN CONTRACT. DENOTES NEW MILLWORK. NEW DOOR AND FRAME. REFER TO DOOR SCHEDULE. EXISTING DOOR AND FRAME. SEE BUILDING SHELL PLAN. AP CARMEL CITY CENTER PEDCOR DESIGN GROUP Architecture / Project Managment: 355 City Center Drive Carmel, Indiana 46032 317.705.7979 (phone) 317.705.7980 (fax) Architect: By: SUITE 68 Lln, KEY PLAN - SCALE: 1/128"= 1'-0" Developer: P E D C O R C,e52-., (?" DEVE11OPMENT CO. Project: U) z M LU � G � U) Z LU L L i � U z � �o LuU� �U w V COPYRIGHT & OWNERSHIP OF DOCUMENTS THIS DOCUMENT IS AN INSTRUMENT OF SERVICES AND IS THE SOLE PROPERTY OF THE ARCHITECT AND PEDCOR DESIGN GROUP, LLC ALL INFORMATION CONTAINED HEREIN IS CONFIDENTIAL ITS SUBMISSION AND DISTRIBUTION TO OTHER PARTIES IS NOT TO BE CONSTRUED AS PUBLICATION IN DEROGATION OF COMMON LAW COPYRIGHT, INTELLECTUAL PROPERTY RIGHTS OR OTHER RESERVED RIGHTS. ALL INFORMATION CONTAINED HEREIN CONSTITUTES THE ORIGINAL AND UNPUBLISHED WORK OF THE ARCHITECT, JAMES R STUTZMAN, AND PEDCOR DESIGN GROUP, LLC NO PART OR WHOLE OF THIS DESIGN. THESE DRAWINGS, OR THE RESULTING BUILDING OR BUILDINGS, OR PORTIONS OF THE RESULTING BUILDING OR BUILDINGS MAY BE DUPLICATED, COPIED. EXHIBITED. PHOTOGRAPHED PUBLISHED MODIFIED OR OTHERWISE DISTRIBUTED IN ANY WAY WITHOUT THE SPECIFIC AND PRIOR WRITTEN CONSENT OF THE ARCHITECT, JAMES R STUTZMAN AND PEDCOR DESIGN GROUP, LLC ® COPYRIGHT 2013 JAMES R. STUTZMAN, AIA Cannel, Indiana Issue Date Drawn By Checked By 5/03/2013 AJR MC Revisions: State Release Set: 5.03.2013 Project Number: Sheet Title: CONSTRUCTION PLAN Sheet Number: A1.2