GENERAL CEILING NOTES:
REFLECTED CEILING LEGEND:
1.
MECHANICALAND ELECTRICAL IS DESIGN -BUILD. DESIGN -BUILD CONTRACTOR & ENGINEER TO
0o
Z
VERIFY EXISTING CONDITIONS AND COORDINATE DESIGN OF RELOCATED AND NEW
° A
RECESSED DOWN LIGHT TO BE: CREE, LR6C-10L W/ RC6 HOUSING OR EQUAL.
DIFFUSERS, SPRINKLER HEADS, FIRE PROTECTION DEVICES, EXIT LIGHTS, EMERGENCY NIGHT
c
PROVIDE DIMMER SWITCH TO DIM TO 5% SEE MFG RECOMMENDED DIMMERS.
LIGHTS, AND THERMOSTATS. DESIGN -BUILD CONTRACTOR TO COORDINATE HIS WORK WITH
h=11
2'X 2' FLUORESCENT FIXTURE TO BE: MERCURY LIGHTING, 54E-3-17-OCT-9-ELB-UNI OR EQUAL
THE LIGHTING PLAN. ALL QUESTIONS ARE TO BE BROUGHT TO THE ATTENTION OF THE
W
L
ARCHITECT BEFORE PROCEEDING. REFER TO MECHANICAL DRAWINGS FOR RELOCATION OF
B
�
U
THERMOSTATS. CONTRACTOR TO VERIFY WITH TENANT THERMOSTAT LOCATIONS FOR
�
PENDANT FIXTURE TO BE: LAMPSPLUS.COM, POSSINI EURO DESIGN, MIRRORED
FURNITURE LOCATION CONFLICTS BEFORE PROCEEDING.
® C
GRIDS METALAND WOOD CHANDELIER #87776. MOUNT AT XX' AFF TO BOTTOM.
2.
ELECTRICAL CONTRACTOR & ENGINEER IS RESPONSIBLE FOR DESIGN -BUILD OF ALL SAFETY
®
CHAIN HUNG LIGHT FIXTURE TO BE: LA LIGHTING, IND200-2-4RH-S10-ELF-2E81 OR
SYSTEMS. ENGINEER IS TO VERIFY QUANTITYAND PLACEMENT OF INDICATED SAFETY
O
EQUAL.
DEVICES (EXIT SIGNS, ALARMS, ETC.)AND VERIFY CONFORMANCE WITH LOCALAND STATE
ry
CODES. DESIGN BUILD CONTRACTOR IS RESPONSIBLE FOR SUBMITTING NECESSARY
CIO
0�
DRAWINGS & ENGINEERED CERTIFICATION CALCULATIONS AND SPECIFICATIONS FOR REVIEW
® E
LINEAR LIGHT FIXTURE TO BE: AXIS LIGHTING, CUBIC, CU S 8 T8 -2 -AP 70UP1
AND OBTAINING PERMITS. CONTRACTOR IS RESPONSIBLE FOR SUBMITTING DRAWINGS TO
co
30DOWN-UNV-ERS-1-CT-C. TO BE ON OCCUPANCY SENSOR.
ARCHITECT FOR REVIEWAND COORDINATION OF LOCATION OF DEVICES.
ALTERNATE 1: LUXIT, PASSWORD COMPLETE SUSPENSION 8', 07C WALNUT WOOD.
CONTACT MELINDA DYKSTRA , 317-577-8338.
3.
ALL WALLS GO TO DECK ABOVE UNLESS NOTED OTHERWISE. SEE CONSTRUCTION PLAN FOR
t
CEILING MOUNTED EXIT LIGHT W/ DIRECTION
OTHER WALL TYPE INFORMATION.
INDICATION DUAL -LITE TO BE: MERCURY LIGHTING MER-ELXTE OR EQUAL,
4.
CONTRACTOR TO VERIFY EXISTING CONDITIONS TO LAYOUT AND REPORT ANY
EXHAUST GRILLE IN CEILING FOR USE WITH BUILDING'S EXHAUST SYSTEM.
DISCREPANCIES TO DESIGNER BEFORE PROCEEDING WITH CONSTRUCTION.
5.
CEILING HEIGHT IS INDICATED BY BENCHMARK UNLESS NOTED OTHERWISE.
2'X 2' SUSPENDED CEILING TO BE: ARMSTRONG, DUNE ANGLED TEGULAR
W/ PRELUDE XL 15/16" GRID.
6.
EACH ROOM TO HAVE INDIVIDUAL SWITCH LOCATED ON WALLAT DOORWAY TO ROOM, TYPICAL
UNLESS NOTED OTHERWISE. IN LOCATIONS OF 2 OR MORE SWITCHES IN CLOSE PROXIMITY,
SWITCHES ARE TO BE CONSOLIDATED TOAGANG PLATE CONDITION.
GYPSUM BOARD CEILING TO BE PAINTED P8.
7.
PROVIDE FIRE RATED DAMPERS REQUIRED AT FIRE RATED WALLS.
19
TWO WAY SWITCH.
8.
ALL LIGHT FIXTURES TO BE 3500K COLOR TEMPERATURE.
3
THREE WAY SWITCH.
9
EMERGENCY STROBES AND LIGHT FIXTURES TO BE WHITE UNLESS NOTED OTHERWISE.
COORDINATE LOCATIONS IN THE FIELD WITH THE ARCHITECTAND TENANT.
D
DIMMER SWITCH.
10.
HVAC DIFFUSERS, GRILLES, AND FIRE SPRINKLERS ARE TO BE CENTERED WITHIN THE CEILING
NL
NIGHTLIGHT LOCATION WITH EMERGENCY BATTERY PACK,
TILE.
REFLECTED CEILING PLAN
SCAT P 114" = 1'-n"
11. MEP CONSULTANT IS TO SUBMIT DRAWINGS SHOWING LOCATIONS OF ALL NECESSARY HORN
STROBES, FIRE PULLS, AND EMERGENCY LIGHTS.
12. MEP CONSULTANT TO RUN THE NECESSARY CALCULATIONS TO DETERMINE THAT THE LIGHTS
LAYOUT MEETS THE ENERGY CODE. IF IT DOES NOT PLEASE ADDRESS THIS WITH THE
ARCHITECTAND THE TENANT TO REVISE LIGHT SELECTIONS AS NEEDED.
CEILING PLAN NOTES:
aEXISTING BULKHEAD FRAMING TO REMAIN.
cP2 PROVIDE 2'x2' SUSPENDED ACOUSTICAL CEILING. SEE LEGEND FOR SPECIFICATIONS.
cP3 PROVIDE PAINTED DRYWALL CEILING WITH RECESSED DOWNLIGHTS. DESIGN -BUILD
CONTRACTOR TO COORDINATE ACCESS PANEL LOCATIONS AND/OR CONTROL JOINTS WITH
ARCHITECT.
cPa PROVIDE OPEN, EXPOSED CEILING TO BE UNFINISHED. PROVIDE SPIRAL DUCT, HARD PIPE
CONDUIT FOR ALL WIRING, ANDALIGNMENT OFALL VISIBLE ITEMS.
cP5 PROVIDE SEPARATE CIRCUIT ON AN INDEPENDANT TIMER FOR THE LIGHTS IN THE RECEPTION
AREA.
cPs ALIGN BULKHEAD WITH FINISHED COLUMN WRAP.
cP' LIGHT FIXTURES TO BE ON OCCUPANCY SENSORS.
cPa PROVIDE DIMMER SWITCHES IN THE CONFERENCE ROOM, CASUAL MEETING, RECEPTION, AND
OFFICES.
CP9 PROVIDE EXHAUST GRILLE IN RESTROOMS TIED TO BUILDING EXHAUST SYSTEM.
CP10 PROVIDE HVAC DISTRIBUTION FROM EXISTING HEAT PUMP UNITS.
cP„ PROVIDE AND INSTALL TIMER CONTROL SYSTEM AT THIS LOCATION TO BE: LEVITON, EZ -MAX
PLUS RELAY CONTROL PANEL OR EQUAL. ALL LIGHTS NOT CONTROLLED WITH OCCUPANCY
SENSORS ARE TO BE CONTROLLED ON THE TIMER. COORDINATE CIRCUITS AND SWITCHING
WITH THE ARCHITECT AND TENANT IN THE FIELD.
cP'2 ADJUST EXISTING BULKHEAD FRAMING TO CREATE WIDOW WELL. SEE DETAIL 7/A4.2.
CP13 PROVIDE EXPANSION JOINT COVER TO BE: C/S GROUP, FCF-200 CEILING EXPANSION JOINT
COVER OR EQUAL. COLOR TBD.
CP14 PROVIDE DRYWALL BULKHEAD AT 8'-0"AFF. ALIGN WITH ADJACENT WALLS. SEE DETAIL 5/A4.2.
CP15 PROVIDE SEPARATE CIRCUIT ON AN INDEPENDANT TIMER FOR THE LIGHTS IN THE OPEN
OFFICE AREA.
i*V
CARMEL
CITY CENTER
PEDCOR DESIGN GROUP
Architecture / Project Managment:
355 City Center Drive
Carmel, Indiana 46032
317.705.7979 (phone)
317.705.7980 (fax)
Architect:
STU
=G\STER
0
By:
STATE OF
d a o a o
0
Qf O O O b O
KEY PLAN _
SCALE: 1/128"= 1'-0"
Developer:
P E D C O R
DEVE11OPMENT CO.
Project:
COPYRIGHT & OWNERSHIP OF DOCUMENTS
THIS DOCUMENTIS AN INSTRUMENT OF SERVICES AND IS THE SOLE
PROPERTY OF THE ARCHITECT AND PEDCOR DESIGN GROUP, LLC ALL
INFORMATION CONTAINED HEREIN IS CONFIDENTIAL. ITS SUBMISSION
AND DISTRIBUTION TO OTHER PARTIES IS NOT TO BE CONSTRUED AS
PUBLICATION IN DEROGATION OF COMMON LAW COPYRIGHT.
INTELLECTUAL PROPERTY RIGHTS OR OTHER RESERVED RIGHTS. ALL
INFORMATION CONTAINED HEREIN CONSTITUTES THE ORIGINAL AND
UNPUBLISHED WORK OF THE ARCHITECT. JAMES R. STUTZMAN. AND
PEDCOR DESIGN GROUP LLC. NO PART OR WHOLE OF THIS DESIGN.
THESE DRAWINGS, OR THE RESULTING BUILDING OR BUILDINGS, OR
PORTIONS OF THE RESULTING BUILDING OR BUILDINGS MAY BE
DUPLICATED, COPIED, EXHIBITED. PHOTOGRAPHED. PUBLISHED.
MODIFIED OR OTHERWISE DISTRIBUTED IN ANY WAY WITHOUT THE
SPECIFIC AND PRIOR WRITTEN CONSENT OF THE ARCHITECT, JAMES R
STUTZMAN AND PEDCOR DESIGN GROUP LLC. O COPYRIGHT 2013
JAMES R. STUTZMAN, AIA. Carmel, Indiana
Issue Date Drawn By Checked By
5/03/2013 AJR Mc
Revisions:
State Release Set: 5.03.2013
Project Number:
Sheet Title:
REFLECTED CLNG
PLAN
Sheet Number:
A1.4
�—
0o
Z
�
M
w
0
c
�
Z
W
L
L
�
U
z
�
(1)
o
wU�
C:
ry
CIO
0�
co
w
�j
COPYRIGHT & OWNERSHIP OF DOCUMENTS
THIS DOCUMENTIS AN INSTRUMENT OF SERVICES AND IS THE SOLE
PROPERTY OF THE ARCHITECT AND PEDCOR DESIGN GROUP, LLC ALL
INFORMATION CONTAINED HEREIN IS CONFIDENTIAL. ITS SUBMISSION
AND DISTRIBUTION TO OTHER PARTIES IS NOT TO BE CONSTRUED AS
PUBLICATION IN DEROGATION OF COMMON LAW COPYRIGHT.
INTELLECTUAL PROPERTY RIGHTS OR OTHER RESERVED RIGHTS. ALL
INFORMATION CONTAINED HEREIN CONSTITUTES THE ORIGINAL AND
UNPUBLISHED WORK OF THE ARCHITECT. JAMES R. STUTZMAN. AND
PEDCOR DESIGN GROUP LLC. NO PART OR WHOLE OF THIS DESIGN.
THESE DRAWINGS, OR THE RESULTING BUILDING OR BUILDINGS, OR
PORTIONS OF THE RESULTING BUILDING OR BUILDINGS MAY BE
DUPLICATED, COPIED, EXHIBITED. PHOTOGRAPHED. PUBLISHED.
MODIFIED OR OTHERWISE DISTRIBUTED IN ANY WAY WITHOUT THE
SPECIFIC AND PRIOR WRITTEN CONSENT OF THE ARCHITECT, JAMES R
STUTZMAN AND PEDCOR DESIGN GROUP LLC. O COPYRIGHT 2013
JAMES R. STUTZMAN, AIA. Carmel, Indiana
Issue Date Drawn By Checked By
5/03/2013 AJR Mc
Revisions:
State Release Set: 5.03.2013
Project Number:
Sheet Title:
REFLECTED CLNG
PLAN
Sheet Number:
A1.4