Loading...
HomeMy WebLinkAbout37(SEE CCLG. PLANS) �' FINISH CEILING X113''-5" FIN. 2ND FLOOR 4100'-0" 'V FINISH FLOOR STAIR SECTION SCALE: 1 2 =1 -0 (SEE STRUCT) jil JOIST BRG. 113'-5" � FIN. 2ND. —FLOOR 100' -0" FINISH FLO GENERAL NOTES: G1. SEE ELEVATIONS AND INTERIOR FINISH PLANS FOR PAINT COLOR AND FINISH SELECTIONS G2. STUD SUPPLIER TO CERTIFY AND DESIGN METAL STUD SYSTEM TO MEET THE CRITERIA IN THE STRUCTURAL DRAWINGS AND SPECIFICATIONS AND TO ACOMMODATE ALL MOVEMENT AND DEFLECTION OF THE STRUCTURAL SYSTEM (SEE SHT. A441) G3. STRUCTURAL ELEMENTS ARE SHOWN FOR BASIC REFERENCE ONLY. NOT ALL STRUCTURAL ELEMENTS THAT MAY BE REQUIRED ARE SHOWN. REFER TO STRUCTURAL PLANS FOR ALL SIZES, MATERIALS, LOADS, DIMENSIONS, AND ANY OTHER REQUIRED STRUCTURAL RELATED INFORMATION. IN THE EVENT THAT STRUCTURAL REFERENCE NFORMATION APPEARING ON THIS SHEET CONFLICTS WITH INFORMATION SHOWN ON THE STRUCTURAL DRAWINGS, THE STRUCTURAL DRAWINGS SHALL TAKE PRECEDENCE. KEY NOTES: 3A SEE STRUCTURAL FOUNDATION PLANS FOR WORK BELOW FINISH FLOOR OR GRADE 3B CONCRETE SLAB ON GRADE (SEE STRUCTURAL) 3C CONCRETE FLOOR SLAB (SEE STRUCTURAL) PRE -CAST CONCRETE WALL PANELS, 12'-0" WIDE & 3D 10" THICK NOM, (SEE PLANS & ELEVATIONS), INSULATED. EMBEDMENT PLATES & BARS, ETC. BY P.C. SUPPLIER. SCORED AS INDICATED ON WALL SECTIONS & ELEVATIONS. PAINTED AS INDICATED ON ELEVATIONS & WALL TYPE/ FINISH PLANS PRE -CAST CONC. REVEAL, 1/2" DEEP, 1-1/2" WIDE 3E AT SURFACE, 1/2" WIDE AT BOTTOM, WITH 45' BEVELED SIDES. SEE EXTERIOR ELEVATIONS FOR VERTICAL REVEALS (SAME PROFILE AS HORIZ. REVEALS. SEE DETAIL 1/A332) 3F 8" PRECAST CONCRETE ROOF PLANKS (SEE STRUCT.) 3G SEE CIVIL FOR SITE CONCRETE OR GRADE (BY OTHERS) 3H CORE DRILL CONCRETE & SET RAIL POST IN EPDXY GROUT 3J CONCRETE STAIR LANDING (SEE STAIR DRAWINGS) 5'x5' OPENING IN PRECAST - INFILL WITH 12"x12" 4A GLASS BLOCK W/ CROSS RIBBED UNIFORM PATTERN, INSTALLED PER GLASS BLOCK MFR. RECOMMENDATIONS 46 8" STANDARD CONCRETE BLOCK (SEE STRUCTURAL FOR REINFORCING) 5A 1 5/8" METAL STUDS (PER STUD SUPPLIER) 5B 3 5/8" METAL STUDS (PER STUD SUPPLIER) 5C 6" METAL STUDS (PER STUD SUPPLIER) 5D 8" METAL STUDS (PER STUD SUPPLIER) 5E METAL STUD BRACE/CONNECTION (PER STUD SUPPLIER) 5F STEEL CHANNEL (SEE STAIR DRAWINGS) SSTAIR TREAD & RISER; CONC. FILLED METAL PAN WITH 5G VINYL TREADS, RISERS & BASE (SEE STAIR DRAWINGS) 5H 1-1/2"0 STEEL HANDRAIL, PAINTED 5J 1-1/2"0 STEEL GUARDRAIL PAINTED 5K WELD PIPE RAIL TO TOP FLANGE OF CHANNEL 5L STEEL COLUMN OR POST (SEE STRUCTURAL DRAWINGS) 5M DEFLECTION CLIP (SEE DRAWING A441) 5N BOXED STUD HEADER OR BEAM (PER STUD SUPPLIER) 5p LINTEL (SEE STRUCTURAL) 5Q ALUMINUM BRAKE METAL WITH FINISH TO MATCH ADJACENT CURTAIN WALL OR STOREFRONT FRAME 5R STEEL TUBE (SEE STRUCTURAL) 5S ALUMINUM BRAKE METAL WITH FINISH TO MATCH ADJACENT CURTAIN WALL OR STOREFRONT FRAME 5T 8" METAL STUD JOIST (PER STUD SUPPLIER) 5U METAL CORNER BEAD 5V STAIR SUPPORT POST (SEE STAIR DRAWINGS) STEEL 1"0 VERTICAL BALLUSTERS AT 4" O.C. MAX., 5W PAINTED 5X 2x2x1/4 STEEL ANGLE (BY STOREFRONT SUPPLIER) 6A 2x TREATED WOOD NAILER 66 3/4" CDX PLYWOOD SHEATHING 6C 5/8" CDX PLYWOOD SHEATHING 6D 3/4" SOLID SURFACE STOOL. EXTEND 1" BEYOND WALL LINE 6E 1/2" EXTERIOR FIBER CEMENT SHEATHING 6F PEEL & STICK 12"x12" VINYL TILE (SELECTED BY OWNER) 7A (2) LAYERS POLYISOCYAN U RATE RIGID INSULATION (5" TOTAL THICKNESS), R-30 MIN. FULLY ADHERED SINGLE PLY HEAT WELDED THERMO- PLASTIC SHEET ROOF MEMBRANE SYSTEM (TPO) 7C EXTEND MEMBRANE FLASHING OVER TOP OF PARAPET ROOF COPING SYSTEM, HICKMAN 'PERMASNAP', MATCH 7D COLOR OF ACM 7E ALUMINUM COMPOSITE MATERIAL (ACM) BUILDING PANEL 7F FLUID APPLIED MOISTURE/AIR BARRIER 7G 1/2" EXPANSION JOINT MATERIAL AND SEALANT 7H FIBERGLASS BATT INSULATION WITH 6 MIL REINFORCED FIRE RETARDANT VAPOR BARRIER, R-19 MIN. 7J 2" RIGID INSULATION, R-10 MIN. 7K BACKER ROD & SEALANT 7L TRIM FLASHING TO SEAL OPENINGS AND/OR ALLOW MOISTURE DRAINAGE AS REQUIRED (COMPONENT OF METAL PANEL SYSTEM) 7M REVEAL IN ACM PANEL (SEE DETAIL 1/A332) 7N CONTINUOUS METAL FLASHING AS REQUIRED 7P SCUPPER AND DOWNSPOUT (SEE ELEVATIONS) 7Q POLYETHELENE VAPOR BARRIER 7R TERMINATION BAR & SEALANT �S CONTINUOUS ALUMINUM TRACK TO ALLOW MOISTURE DRAINAGE 7T METAL BOX SCUPPER & DOWNSPOUT (SEE SHEET A461) OFILL EXPOSED EXTERIOR TUBE WITH ON-SITE INJECTED 7U FOAM INSULATION VV LINEAR METAL CEILING WITH CARRIER CHANNELS OREFER TO MECHANICAL PLANS FOR EXTENT OF HEATED �\N SLAB AND RIGID INSULATION IN SHOWROOM 7X METAL FLASHING INSTALLED ON PRECAST TO ALLOW PROPER DRAINAGE OF STOREFRONT & ACM SYSTEMS FINISH/COLOR TO MATCH STOREFRONT SYSTEM PRECASTER NOTE: SLOPE PRECAST 1/2" OUTSIDE OF STOREFRONT FRAMING (SEE DETAIL 2/A332) 7Y FIRE STOP INSULATION & CAULKING TO SEAL TIGHT 8A DOOR (SEE PLANS & A5xx SHEETS) 8B DOOR, OVERHEAD (SEE PLANS & A5xx SHEETS) 8C COILING SECURITY DOOR. (SEE A5xx SHEETS) ALUMINUM STOREFRONT SYSTEM, 4 1/2"x2" MULLIONS 8D (SEE PLANS & A5xx SHEETS) SE ALUMINUM WINDOW SYSTEM (SEE PLANS & A5xx SHEETS) 5/8" TYPE 'X' GYPSUM BOARD (GYP. BD. ABOVE 9A CEILING TO BE TAPED ONLY) 9B ACOUSTICAL TILE CEILING (SEE CEILING PLANS) 9C RESILIENT CHANNELS FOR GYP. BD. CEILING SUPPORT, BRACE TO STRUCTURE AS REQUIRED VI K � _woW K ZHww Or z InZ O �O 20 offi N Z= Z V H ZH� U W d'J W gym? o33oON`nzao�y�� Z W w O �QQ i U O w Z 3 F °NZ='Z O RLI' I"FU° U NN W °z—�a0Yw�0=FOFOw¢� FD%%iao3sam- o�a�mog0a-wo a_, Z w J — z a U Q LL O 00 cIn ti= 00 © 2013 BALAY ARCHITECTS, INC. >= ��//!1111 111111\\\ W W > Q W � Lu � J Q O o Z Q lom W = Ld z W Of I-_ Q rn (10 1N\I(I ON y - =jam C;'-1 Lu a IJJ Ln z c:) a �_ __ O 00 cIn ti= 00 © 2013 BALAY ARCHITECTS, INC. ��//!1111 111111\\\ 0 0 0 n 0 0 U co ro t° co m •� 01 C+Oj U A Z m [com m i H m a � WALL SECTIONS A331 DoffO >H Lu D © 2013 BALAY ARCHITECTS, INC. WALL SECTIONS A331