HomeMy WebLinkAbout55SPECIAL INSPECTION REQUIREMENTS BUILDING CODE SECTION 1704 & 1707 REQUIRES A SPECIAL INSPECTOR TO OBSERVE THE WORK ASSIGNED FOR CONFORMANCE TO THE APPROVED DESIGN DRAWINGS AND SPECIFICATIONS. THESE INSPECTIONS ARE IN ADDITION TO INSPECTIONS SPECIFIED ELSEWHERE. PROFESSIONAL ENGINEERS' GROUP, INC. DOES NOT PROVIDE THESE INSPECTIONS. THE OWNER SHALL RETAIN THE SERVICES OF A MATERIAL TESTING AGENCY TO MAKE AVAILABLE A SPECIAL INSPECTOR WHO SHALL PROVIDE INSPECTIONS DURING CONSTRUCTION ON THE TYPES OF LISTED WORK. SPECIAL INSPECTOR SHALL SUBMIT COPIES OF INSPECTION REPORTS TO THE CONSTRUCTION MANAGER AND THE STRUCTURAL ENGINEER. SPECIAL INSPECTION REQUIREMENTS FOR WIND RESISTANCE INSPECTION TASKS ROOF CLADDING AND ROOF FRAMING CONNECTIONS INSPECTION FOR STEEL MATERIALS INSPECTION TASK I FREQUENCY OF INSPECTION CONSTRUCTION SAFETY &STABILITY THE STRUCTURE HAS BEEN DESIGNED ONLY FOR THE IN-SERVICE LOADS. THE METHODS AND MEANS OF CONSTRUCTION ARE THE RESPONSIBILITY OF THE CONTRACTOR. THE CONTRACTOR SHALL TAKE ALL NECESSARY PRECAUTIONS TO INSURE SAFE WORKING CONDITIONS, PROVIDE FOR PUBLIC SAFETY AND MAINTAIN THE INTEGRITY OF THE STRUCTURE DURING ALL STAGES OF CONSTRUCTION. THE STRUCTURAL STEEL FRAME, IN THE COMPLETELY ERECTED AND FULLY CONNECTED STATE REQUIRES INTERACTION WITH NON-STRUCTURAL STEEL ITEMS (METAL DECK AND SHEAR WALLS, EITHER MASONRY OR CONCRETE) FOR STRENGTH AND/OR STABILITY. TEMPORARY BRACING DURING CONSTRUCTION IS REQUIRED. TEMPORARY SUPPORTS AND BRACES INSTALLED DURING ERECTION SHALL REMAIN IN PLACE UNTIL COMPLETION OF THE INSTALLATION OF THE STRUCTURAL STEEL FRAME, DIAPHRAGM ELEMENTS AND REFERENCE FOR LATERAL -LOAD -RESISTING SYSTEM. CRITERIA MASONRY AND CONCRETE WALLS ARE NOT DESIGNED TO BE STABLE DURING CONSTRUCTION. THE CONTRACTOR CMU WALL CONNECTION TO ROOF DIAPHRAGM AND FRAMING 1. MATERIAL VERIFICATION OF HIGH STRENGTH AISC ASD, SEC. A3.4 SHALL RETAIN A PROFESSIONAL ENGINEER TO DESIGN BRACING FOR THE WALLS. THE CONTRACTOR SHALL BOLTS, NUTS AND WASHERS OR INSTALL BRACES IN A TIMELY MANNER TO PREVENT COLLAPSE OF THE WALLS. BRACES SHALL REMAIN IN PLACE ROOF DIAPHRAGM SYSTEMS AISC LRFD, SEC. A3.3 UNTIL STRUCTURAL ELEMENTS PROVIDING LATERAL SUPPORT FOR THE WALLS ARE IN PLACE AND THE WALLS --- A. IDENTIFICATION MARKINGS TO CONFORM PERIODIC HAVE ATTAINED THE STRENGTH REQUIRED BY THE CONTRACT DOCUMENTS. THE CONTRACTOR SHALL INSPECT VERTICAL WIND FORCE RESISTING SYSTEMS TO ASTM STANDARDS SPECIFIED IN THE BRACES DAILY AND MAKE ADJUSTMENTS, REPAIRS OR REPLACEMENTS AS REQUIRED INSURING THE _ __ THE APPROVED CONSTRUCTION DOCUMENTS STABILITY OF THE WALLS. VERTICAL WIND FORCE RESISTING SYSTEMS CONNECTIONS TO FOUNDATION B. MANUFACTURER'S CERTIFICATE OF PERIODIC _-------------- . ___ ----------- COMPLIANCE FABRICATION AND INSTALLATION OF SYSTEMS OR COMPONENTS REQUIRED TO MEET THE IMPACT RESISTANT REQUIREMENTS OF IBC SECTION 1609.1.2 2. HIGH STRENGTH BOLTING ------------ --- - COMPLETE AND PARTIAL PENETRATION GROVE WELDS MULTI -PASS FILLET WELDS ----------------------------------------- SINGLE -PASS FILLET WELDS FLOOR AND ROOF DECK WELDS AISC LRFD, SEC. M2.5 THE CONTRACTOR, ERECTOR OR FABRICATOR SHALL NOTIFY THE ENGINEER OF RECORD AND THE OWNER'S --------------- D1.1 D1.1 D1.1 D1.3 ACI 318: CH. 4 5.2-5.4 ACI 318: 5.6, 5.8 ASTM C-172, C31 PERIODIC DESIGNATED REPRESENTATIVE FOR CONSTRUCTION IF CHANGES ARE REQUIRED TO THE STRUCTURAL STEEL FRAME TO ALLOW ERECTION TO CONFORM TO OSHA REGULATIONS, INCLUDING SUB -PART R. BIDS SHALL BE ------------------------------- ------ THE CONTRACTOR RESPONSIBLE FOR CONSTRUCTION OF THE MAIN WIND FORCE RESISTING SYSTEM OR COMPONENT LISTED A. BEARING TYPE CONNECTIONS ---- PERIODIC ABOVE SHALL SUBMIT A WRITTEN STATEMENT OF RESPONSIBILITY TO THE BUILDING OFFICIAL PRIOR TO COMMENCEMENT OF D1.1 BASED ON THE ERECTION METHOD CHOSEN BY THE CONTRACTOR OR ERECTOR. BIDS SHALL INCLUDE THE COST FOR MODIFICATIONS OF THE STRUCTURAL STEEL, STEEL JOISTS, JOIST GIRDERS, METAL DECK OR B. SLIP CRITICAL CONNECTIONS 5.10 WORK ON THE SYSTEM OR COMPONENT. REFERENCE BUILDING CODE SECTION 1706.1 FOR REQUIREMENTS OF THIS VERIFICATION OF WELDABILITY OF REINFORCING STEEL -- CONTINUOUS AWS LATERAL -LOAD -RESISTING SYSTEM BASED ON THE CHOSEN METHOD. 3. MATERIAL VERIFICATION OF STRUCTURAL STEEL ACI 318: 5.11, ASTM A6 OR ASTM A588 STATEMENT OF RESPONSIBILITY. - SHEAR REINFORCEMENT REQUIRED INSPECTIONS DURING CONCRETE CONSTRUCTION A. MATERIAL IDENTIFICATION MARKINGS PERIODIC BUILDING --------------------------------------------------------------------- B. CERTIFIED MILL TEST REPORTS ------------------------------------------------------- OTHER REINFORCEMENT NOTICE TO CONTRACTORS WORKING ON ROOF DECK: AWS D1.4 GA. INSPECTION TASK FREQUENCY OF REFERENCE FOR I BRG. PERIODIC GALV. GALVANIZED OPP. INSPECTION CRITERIA STEEL DECK INSTITUTE REQUIRES THE ROOF DECK TO SUPPORT A CONCENTRATED CONSTRUCTION LOAD OF 200 POUNDS AT MID SPAN OF 4. MATERIAL VERIFICATION WELD FILLER MATERIAL GRANULAR PC 1. INSPECTION OF REINFORCING STEEL INCLUDING PLACEMENT 2. INSPECTION OF REINFORCING STEEL WELDING IN ACCORDANCE WITH "INSPECTION FOR STEEL MATERIALS" 3. INSPECT ANCHOR RODS INSTALLED IN CONCRETE (ONLY RODS WITH DOUBLE NUTS ON BOTTOM) 4. VERIFY USE OF REQUIRED MIX DESIGN 5. SAMPLING OF FRESH CONCRETE, INCLUDING: SLUMP, AIR CONTENT, CONCRETE TEMPERATURE AT THE TIME OF MAKING SPECIMENS FOR STRENGTH EVALUATION 6. INSPECTION OF CONCRETE PLACEMENT FOR PROPER TECHNIQUES 7. INSPECTION FOR MAINTENANCE OF SPECIFIED CURING TEMPERATURES AND TECHNIQUES 8. ERECTION OF PRECAST CONCRETE MEMBERS PERIODIC PERIODIC CONTINUOUS PERIODIC CONTINUOUS CONTINUOUS PERIODIC PERIODIC AISC ASD, SECTIONS - A ONE -FOOT WIDE SECTION OF DECK. CONSTRUCTION LOADS SHALL NOT - A3.5 & A3.6 EXCEED THIS VALUE NOR THE UNIFORM LIVE LOAD VALUE SHOWN IN THE DESIGN DATA SECTION OF THE A. CONFORMANCE TO AWS SPECIFICATION PERIODIC DRAWINGS. ACI 318: 3.5, 7.1-7.7 AS SPECIFIED IN THE APPROVED PLANS AND SPECIFICATIONS. SUB -CONTRACTOR SHALL DISTRIBUTE LOADS TO ROOF DECK BY APPROPRIATE MEANS TO PREVENT DAMAGE ----------------------- ----------- -----........_-- - - --------- OF THE ROOF DECK BY CONSTRUCTION ACTIVITIES. SUB -CONTRACTOR IS SOLELY RESPONSIBLE FOR MEANS B. MANUFACTURER'S CERTIFICATE OF PERIODIC AND METHODS OF CONSTRUCTION. SUB -CONTRACTOR CAUSING DAMAGE TO ROOF DECK DURING ACI 318: 3.5.2 COMPLIANCE AWS D1.4 CONSTRUCTION IS RESPONSIBLE FOR THE COST OF REMOVAL AND REPLACEMENT OF DAMAGED DECK. EXPENSES MAY INCLUDE FEES CHARGED BY THE ENGINEER, ARCHITECT OR TESTING AGENCIES FOR REVIEW 5a. WELDING OF STRUCTURAL STEEL AND INSPECTION OF THE ROOF DECK BEFORE AND AFTER REPAIRS. IBC: 1912.5 CONSTRUCTION 1. 2. 3. 4. ------------ --- - COMPLETE AND PARTIAL PENETRATION GROVE WELDS MULTI -PASS FILLET WELDS ----------------------------------------- SINGLE -PASS FILLET WELDS FLOOR AND ROOF DECK WELDS - --- - CONTINUOUS CONTINUOUS ---------------------------------------- __-------------------- _- PERIODIC PERIODIC -- AWS AWS ----------------_-....--_ AWS AWS --------------- D1.1 D1.1 D1.1 D1.3 ACI 318: CH. 4 5.2-5.4 ACI 318: 5.6, 5.8 ASTM C-172, C31 PERIODIC ACI 5b. WELDING OF REINFORCING STEEL_ AWS D1.1 ARTICLE 3.38 ACI 318: 5.9, 5.10 1. VERIFICATION OF WELDABILITY OF REINFORCING STEEL -- PERIODIC AWS D1.4 NUMBER ACI 318: 5.11, 5.13 2. - SHEAR REINFORCEMENT CONTINUOUS AWS D1.4- BUILDING FT. 3. OTHER REINFORCEMENT PERIODIC AWS D1.4 GA. ACI 318: Ch. 16 6. STEEL FRAME JOINT DETAILS BRG. APPROVED 9. EVALUATION OF CONCRETE STRENGTH PERIODIC ACI 318: 5.6 1. DETAILS AT BRACES AND STIFFENER PLATES -- -�� PERIODIC - DOCUMENTS TEMPERATURES AND TECHNIQUES REINFORCING STEEL LEVEL 1 SPECIAL INSPECTIONS FOR MASONRY CONSTRUCTION2. MEMBER LOCATIONS PERIODIC -- ------------------_------------------------- -... -------------- - ------------------------------------------------- 3. APPLICATION OF JOINT DETAILS AT PERIODIC INSPECTION TASK FREQUENCY OF REFERENCE FOR AT EACH CONNECTION INSPECTION CRITERIA 1. AS MASONRY CONSTRUCTION BEGINS, VERIFY COMPLIANCE OF THE FOLLOWING WITH THE CONSTRUCTION DOCUMENTS AND REVIEWED SUBMITTALS. A. PROPORTIONS OF SITE PREPARED MORTAR B. CONSTRUCTION OF MORTAR JOINTS C. LOCATION OF REINFORCEMENT, CONNECTORS AND ANCHORS 2. VERIFY THE FOLLOWING: A. SIZE AND LOCATION OF STRUCTURAL ELEMENTS B. ANCHOR TYPE, SIZE AND LOCATION, INCLUDING DETAILS OF ANCHORAGE OF MASONRY TO STRUCTURAL MEMBERS, FRAMES OR OTHER CONSTRUCTION. C. REINFORCEMENT SIZE, GRADE AND TYPE CONFORMS TO SPECIFICATIONS D. WELDING OF REINFORCEMENT AND HEADED STUD ANCHORS ............ - .... __---------- -------------- --------- ------- -- E. PROTECTION OF MASONRY DURING COLD WEATHER (TEMPERATURE BELOW 40'F) F. PROTECTION OF MASONRY DURING HOT WEATHER (TEMPERATURE ABOVE 90'F) 3. PRIOR TO GROUTING, VERIFY THE FOLLOWING: A. GROUT SPACE IS CLEAN B. PLACEMENT OF REINFORCEMENT AND DEVICES TO HOLD REINFORCEMENT IN PLACE DURING GROUTING C. PROPORTIONS OF SITE -PREPARED GROUT D. CONSTRUCTION OF MORTAR JOINTS 4. VERIFY GROUT PLACEMENT CONFORMS WITH CODE AND CONSTRUCTION DOCUMENTS 5. OBSERVE PREPARATION OF GROUT SPECIMENS, MORTAR SPECIMENS AND/OR PRISMS 6. COMPLIANCE WITH INSPECTION PROVISIONS OF CONSTRUCTION DOCUMENTS AND CODE AND APPROVED SUBMITTALS SPECIAL INSPECTIONS FOR POST INSTALLED ANCHORS POST INSTALLED ANCHORS MUST BE TESTED PRIOR TO THEIR USE TO SUPPORT OR RESIST ANY LOADS. NOT LESS THAN 25% OF POST INSTALLED ANCHORS SHALL BE TESTED. TESTING MAY USE TORQUE TESTS OR PERIODIC ACI 530.1 ARTICLE 2.6A PULL OUT TESTS. PERIODIC ACI 530.1 ARTICLE 3.3B PERIODIC ACI 530.1 ARTICLE 3.4 PERIODIC ACI 530.1 ARTICLE 3.3G PERIODIC ACI 530 SECTIONS 1.15.4, 2.1.2 PERIODIC ACI 530 SECTION 1.12 ACI 530.1 ARTICLE 2.4, 3.4 CONTINUOUS ACI 530 SECTION 2.1.8.6 PERIODIC I ACI 530.1 ARTICLE 1.8C PERIODIC I ACI 530.1 ARTICLE 1.81) PERIODIC ACI 530.1 ARTICLE 3.21) PERIODIC ACI ACI 530.1 530.1 SECTION 1.12 ARTICLE 3.4 PERIODIC ACI 530.1 ARTICLE 2.66 PERIODIC ACI 530.1 ARTICLE 3.38 CONTINUOUS ACI 530.1 ARTICLE 3.5 CONTINUOUS I ACI 530.1 ARTICLE 1.4 PERIODIC I ACI 530.1 ARTICLE 1.5 ABBREVIATIONS A.R. ANCHOR ROD FIN. FINISH NIC NOT IN CONTRACT ARCH. ARCHITECTURAL FD FLOOR DRAIN NS NEAR SIDE B.L. BUILDING LINE FS FAR SIDE NTS NOT TO SCALE B/BM BOTTOM OF BEAM FDN. FOUNDATION NO. NUMBER B/F BOTTOM OF FOOTING FTG. FOOTING OC ON CENTER BLDG. BUILDING FT. FEET OFD OVERFLOW DRAIN 8M. BEAM GA. GAUGE OSF OUTSIDE FACE BRG. BEARING GALV. GALVANIZED OPP. OPPOSITE C.J. CONSTRUCTION OR CONTROL JOINT GRAN. GRANULAR PC PRECAST CONCRETE CENTERLINE HK. HOOK PL PLATE CLR. CLEAR HORIZ. HORIZONTAL PSF POUNDS PER SQUARE FOOT CMU CONCRETE MASONRY UNIT HSA HEADED STUD ANCHOR RD ROOF DRAIN COL. COLUMN HSS HOLLOW STRUCTURAL SECTION REINF. REINFORCEMENT CONC. CONCRETE IJ ISOLATION JOINT REQ'D. REQUIRED CONNX CONNECTION ISF INSIDE FACE CONST. CONSTRUCTION IN. INCH REV. REVISION CONT. CONTINUOUS INSUL. INSULATION SEC. SHT. SECTION SHEET CONTR. CONTRACTOR J/B JOIST BEARING SIM. SIMILAR D.L. DET. DEAD LOAD DETAIL JST. JOIST SPA. SPACES OR SPACING 15K DIAMETER JT. JOINT SPECS SPECIFICATIONS BING. DRAWING LB. POUND STL STEEL DWL. DOWEL LL LIVE LOAD STD STANDARD EACH END LLH LONG LEG HORIZONTAL STR. STRUCTURE OR STRUCTURAL F J EACH FACE LLV LONG LEG VERTICAL T&B TOP & BOTTOM EW EACH WAY LSH LONG SIDE HORIZONTAL T/BM TOP OF BEAM EA. EACH LSV LONG SIDE VERTICAL T/FTG TOP OF FOOTING EXPANSION JOINT MO MAT'L MASONRY OPENING TYP• TYPICAL EL. ELEVATION MAX. MATERIAL MAXIMUM UNO UNLESS NOTED OTHERWISE EOD EDGE OF DECK MIN. MINIMUM VERT. VERTICAL EOS EDGE OF SLAB MISC MISCELLANEOUS WWR WELDED WIRE REINFORCEMENT EQ. EQUAL W/ WITH EXIST. EXISTING EXP. EXPANSION BUILDING CODE INFORMATION BUILDING CODE AND DESIGN DATA THE BUILDING STRUCTURE HAS BEEN DESIGNED IN ACCORDANCE WITH THE INTERNATIONAL BUILDING CODE, 2006 EDITION WITH AMENDMENTS ROOF DESIGN LOADS LIVE/RAIN/SNOW...................................................25 PSF DEAD LOADS: ......................................................... 15 TO 25 PSF GROUND SNOW LOAD (Pg)...................................20.0 PSF FLAT -ROOF SNOW LOAD (PF)..............................14.0 PSF SNOW EXPOSURE FACTOR(CE)..............................1.0 SNOW IMPORTANCE FACTOR(1)..............................1.0 SNOW THERMAL FACTOR.........................................1.0 OFFICE FLOOR DESIGN LOADS LIVELOAD............................................................. 100 PSF DEADLOADS......................................................... 55 PSF STORAGE DESIGN LOADS LIVELOAD............................................................. 125 PSF DEADLOADS......................................................... 55 PSF LIVE LOAD HAS BEEN REDUCED AS ALLOWED BY THE BUILDING CODE. WIND DESIGN DATA BASIC WIND SPEED (3 SECOND GUST)...............90 MPH WIND LOAD IMPORTANCE FACTOR (1) ...................1.0 WIND EXPOSURE CATEGORY..................................0 INTERNAL PRESSURE COEFFICIENT .......................+/- 0.18 WIND DESIGN PRESSURE (P)...............................VARIES WITH HEIGHT SEISMIC DESIGN DATA OCCUPANCY CATEGORY...........................................II SEISMIC IMPORTANCE FACTOR (1) .........................1.0 SITECLASS............................................................0 MAPPED SPECTRAL RESPONSE ACCELERATIONS: SS........................................................................0.180 S1........................................................................0.080 DESIGN SPECTRAL ACCELERATION PARAMETERS: SDS......................................................................0.144 SD1......................................................................0.091 SEISMIC DESIGN CATEGORY...................................B BASIC SEISMIC RESISTING -SYSTEM: STRUCTURAL STEEL SYSTEM NOT SPECIFICALLY DETAILED FOR SEISMIC RESISTANCE & ORDINARY PRECAST CONCRETE SHEARWALLS DESIGN BASE SHEAR...........................................Cs*W SEISMIC RESPONSE COEFFICIENTS CS................0.064 RESPONSE MODIFICATION FACTORS R: ................ 3.0 ANALYSIS PROCEDURE UTILIZED...... EQUIVALENT LATERAL FORCE PROCEDURE DRAWING INDEX SHEET NO. DESCRIPTION S101 CODE INFORMATION AND SPECIAL INSPECTION REQUIREMENTS S102 GENERAL NOTES S201 FOUNDATION PLAN - AREA 'A' S202 FOUNDATION PLAN - AREA 'B' S203 2nd FLOOR FRAMING PLAN - AREA 'C' S204 ROOF FRAMING PLAN - AREA 'A' S205 ROOF FRAMING PLAN - AREA 'B' S301 FOUNDATION DETAILS S302 FOUNDATION DETAILS S303 FOUNDATION DETAILS S304 MASONRY DETAILS S311 FLOOR FRAMING DETAILS S321 ROOF FRAMING DETAILS S322 ROOF FRAMING DETAILS S323 ROOF FRAMING DETAILS S324 ROOF FRAMING DETAILS S401 SPECIFICATIONS S402 SPECIFICATIONS S403 SPECIFICATIONS S404 SPECIFICATIONS