HomeMy WebLinkAbout92IR -6
FIRST FLOOR PLUMBING PLAN
SCALE: 1/8" = 1'-0"
GENERAL NOTES:
1. REFERENCE SHEET M-001 FOR LEGENDS,
ABBREVIATIONS, SPECIFICATIONS AND NOTES.
2. REFERENCE DETAILS D AND E ON SHEET M003
FOR PIPE HANGER DETAILS.
KEY NOTES:
1O PROVIDE SYMMONS 6-400 A THERMOSTATIC MIXING
VALVE WITH HOSE BIB CONNECTION ON MIXED
WATER SUPPLY. SEE DETAIL G ON SHEET M003.
O2 DROP 3/4" AIR LINES TO LIFT STATIONS AND
CONNECT PER EQUIPMENT MANUFACTURE.
PROVIDE 1/2" CONNECTION POINT WITH DIRT LEG,
VALVE AND QUICK CONNECT FITTING. COORDINATE
FITTING STYLE AND EXACT LOCATION WITH
OWNERS REPRESENTATIVE. REFERENCE DETAIL P
ON SHEET M002. TYPICAL.
3O DROP 3/4" AIR LINES DOWN WALL TO WORK
STATIONS AND PROVIDE TWO 1/2" CONNECTION
POINTS, EACH WITH VALVE AND QUICK CONNECT
FITTING. COORDINATE FITTING STYLE AND EXACT
LOCATION WITH OWNERS REPRESENTATIVE.
TYPICAL. REFERENCE DETAIL B ON SHEET M003
TYPICAL.
4O PLUMBING CONTRACTOR TO PROVIDE A 1-1/2"
COLD WATER AND 3/4" COMPRESSED AIR LINE TO
CARWASH, COORDINATE WITH CARWASH
CONTRACTOR FOR EXACT LOCATION AND
CONNECTION DETAILS. PROVIDE DOUBLE CHECK
BACK FLOW, SHUT OFF VALVES AND PIPING
SPECIALTIES AS REQUIRED BY MANUFACTURER.
O5 INSTALL WATER HEATER FOR CAR WASH BAY
MIXING VALVE ABOVE SINK ON SHELF. SEE DETAIL J
ON M003.
O6 CONNECT OWNER PROVIDED AIR COMPRESSOR,
DRYERS AND FILTERS AS RECOMMENDED BY
MANUFACTURER. ROUTE 2-1/2" MAIN TO SERVICE
BAY. PROVIDE SHUT OFF ISOLATION AND BY-PASS
LINES FOR EACH DRYER AND FILTER.
O7 PROVIDE 1" AIR LINE WITH VALVE AT MAIN AND
ROUTE TO TIRE CHANGING EQUIPMENT.
COORDINATE CONNECTION WITH EQUIPMENT
PROVIDER.