Loading...
HomeMy WebLinkAboutWWC 4 - Truss DetailsDE DANSCO ENGINEERING, LLC P.O. Box 3400 Apollo Beach, FL 33572 Telephone (813) 645-0166 Facsimile (813) 645-9698 The truss drawing(s) listed below have been prepared by Stark Truss, Inc. under my direct supervision based on the parameters provided by the truss designers. Job: 1802242-12T 101 truss design(s) 59223-W1 6/13/18 Samuel A. Greenberg, P.E. Indiana Reg. #19700485 Note: Gable end frames with stud lengths exceeding 4’ require permanent bracing. On structural gables, where studs may be made from two or more boards as they cross diagonals, the 4’ length is the distance from the top chord to bottom chord. The seal on these drawings indicate acceptance of professional engineering responsibility solely for the truss components shown. The suitability and use of this component for any particular building is the responsibility of the building designer, per ANSI/TPI 1-2007 Chapter 2. Warning !—Verify design parameters and read notes before use. These designs are based only upon parameters shown, and are for individual building components to be installed and loaded vertically. Applicability of design parameters and proper incorporation of component is responsibility of building designer – not truss designer or truss engineer. Bracing shown is for lateral support of individual web members only. Additional temporary bracing to ensure stability during construction is the responsibility of the erector. Additional permanent bracing of the overall structure is the responsibility of the building designer. For general guidance regarding fabrication, quality control, storage, delivery, erection and bracing, consult ANSI/TPI 1 National Design Standard for Metal Plate Connected Wood Truss Construction and BCSI 1-03 Guide to Good Practice for Handling, Installing & Bracing of Metal Plate Connected Wood Trusses from Truss Plate Institute, 583 D’Onofrio Drive, Madison, WI 53719 DE Job # 59223-W1 Dansco Engineering, LLC Date: 6/13/18 WARNING – VERIFY DESIGN PARAMETERS AND READ NOTES BEFORE FABRICATION AND INSTALLATION!!! This truss design is adequate for the design parameters shown. Review and approval of design parameters is the responsibility of the building designer, not the truss designer or truss engineer. Permanent bracing requirements against out-of-plane buckling are noted/shown for individual truss members (and for the truss as a whole) subjected to gravity and wind loads. Additional permanent bracing design shall be the responsibility of the design professional of record. Temporary and erection bracing shall be the responsibility of the contractor. Reference ANSI/TPI-1, “National Design Standard for Metal Plate Connected Wood Truss Construction” and TPI/WTCA BCSI-06, “Building Component Safety Information Guide to Good Practice for Handling, Installing, Restraining and Bracing of Metal Plate Connected Wood Trusses” for additional information. Job 1802242-12T Truss J01 TrussType Jack-OpenGirder Qty 1 Ply 1 1802242-12TDWHWoodside-West Clay- 4 Job Reference (optional)Run:8.200 s Apr72018 Print:8.200 s Apr72018MiTekIndustries,Inc.Tue Jun1221:11:162018 Page1ID:bRTO9oDnRLEHvJjVgeMKW3yF_s1-yEMYWmoQvGQnih14kUZUw3eHrJrhvVu6Q2HSxSz6wH9 Scale=1:14.4 T1 B1 1 7 8 2 9 3 2x4 4-7-10 4-7-10 4-7-10 4-7-10 0 -4 -12 2 -3 -14 1 -11 -7 2 -3 -14 4.9912 LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 10.0 SPACING- PlateGrip DOL Lumber DOL RepStressIncr Code 2-0-0 1.15 1.15 NO IBC2012/TPI2007 CSI. TC BC WB Matrix-MP 0.19 0.15 0.00 DEFL. Vert(LL) Vert(TL) Horz(TL) in 0.03 -0.04 -0.00 (loc) 3-6 3-6 2 l/defl >999 >999 n/a L/d 240 180 n/a PLATES MT20 Weight: 11 lb FT= 20% GRIP 197/144 LUMBER- TOP CHORD2x4SPF No.2 BOT CHORD2x4SPF No.2 BRACING- TOP CHORD Structuralwoodsheathing directly applied or 4-7-10 oc purlins. BOT CHORD Rigidceiling directly applied or 10-0-0 oc bracing. MiTekrecommends that Stabilizers and requiredcross bracing beinstalled during truss erection,in accordancewithStabilizer Installation guide. REACTIONS.(lb/size)1=62/Mechanical, 2=83/Mechanical, 3=41/MechanicalMax Horz1=83(LC 16) Max Uplift1=-69(LC 16), 2=-51(LC 12) MaxGrav1=82(LC 7), 2=97(LC 2), 3=74(LC 7) FORCES.(lb)-Max. Comp./Max.Ten.-All forces 250 (lb) orless exceptwhenshown. NOTES- 1)Wind:ASCE 7-10;Vult=115mph(3-second gust)Vasd=91mph;TCDL=6.0psf;BCDL=6.0psf; h=25ft; Cat. II;Exp C; enclosed; MWFRS(envelope) gable end zone;cantileverleft and right exposed ; end verticalleft and right exposed; Lumber DOL=1.60 plategrip DOL=1.60 2)TCLL:ASCE 7-10;Pr=20.0 psf(roofliveload: Lumber DOL=1.15Plate DOL=1.15);Pg=20.0 psf(groundsnow);Pf=15.4 psf(flat roofsnow: Lumber DOL=1.15Plate DOL=1.15); CategoryII;Exp C; PartiallyExp.; Ct=1.1 3) Unbalancedsnowloads have been considered for this design. 4)This truss has been designed for a 10.0 psf bottomchordliveload nonconcurrentwith any otherliveloads. 5) Refer to girder(s) for truss to trussconnections. 6)Providemechanicalconnection(by others) of truss to bearing platecapable of withstanding 100 lb uplift at joint(s) 1, 2. 7)This trussis designedin accordancewith the 2012 InternationalBuilding Code section 2306.1 and referencedstandardANSI/TPI 1. 8) Hanger(s) or otherconnection device(s)shall be providedsufficient to supportconcentratedload(s) 64 lb down and 11 lb up at 2-4-2 on top chord, and 11 lb down and 10 lb up at 2-4-2 on bottomchord.The design/selection of suchconnection device(s)is the responsibility of others. 9)In the LOAD CASE(S)section,loads applied to the face of the truss are noted as front(F) or back(B). LOADCASE(S)Standard 1) Dead +Snow(balanced): LumberIncrease=1.15,PlateIncrease=1.15 Concentrated Loads(lb)Vert: 9=2(F) Trapezoidal Loads(plf) Vert: 1=0(F=25,B=25)-to-2=-59(F=-4,B=-4), 4=0(F=10,B=10)-to-3=-23(F=-2,B=-2) DE Job # 59223-W1 Dansco Engineering, LLC Date: 6/13/18 WARNING – VERIFY DESIGN PARAMETERS AND READ NOTES BEFORE FABRICATION AND INSTALLATION!!! This truss design is adequate for the design parameters shown. Review and approval of design parameters is the responsibility of the building designer, not the truss designer or truss engineer. Permanent bracing requirements against out-of-plane buckling are noted/shown for individual truss members (and for the truss as a whole) subjected to gravity and wind loads. Additional permanent bracing design shall be the responsibility of the design professional of record. Temporary and erection bracing shall be the responsibility of the contractor. Reference ANSI/TPI-1, “National Design Standard for Metal Plate Connected Wood Truss Construction” and TPI/WTCA BCSI-06, “Building Component Safety Information Guide to Good Practice for Handling, Installing, Restraining and Bracing of Metal Plate Connected Wood Trusses” for additional information. Job 1802242-12T Truss J02 TrussType Jack-Open Qty 1 Ply 1 1802242-12TDWHWoodside-West Clay- 4 Job Reference (optional)Run:8.200 s Apr72018 Print:8.200 s Apr72018MiTekIndustries,Inc.Tue Jun1221:11:162018 Page1ID:bRTO9oDnRLEHvJjVgeMKW3yF_s1-yEMYWmoQvGQnih14kUZUw3eIsJtOvVu6Q2HSxSz6wH9 Scale=1:11.2 T1 B1 1 2 3 4 2x4 1-1-12 1-1-12 -1-2-12 1-2-12 1-1-12 1-1-12 0 -5 -12 1 -4 -1 0 -10 -9 1 -4 -1 9.0012 PlateOffsets(X,Y)-- [2:0-4-0,0-0-9] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 10.0 SPACING- PlateGrip DOL Lumber DOL RepStressIncr Code 2-0-0 1.15 1.15 YES IBC2012/TPI2007 CSI. TC BC WB Matrix-MP 0.12 0.04 0.00 DEFL. Vert(LL) Vert(TL) Horz(TL) in 0.00 0.00 -0.00 (loc) 7 7 3 l/defl >999 >999 n/a L/d 240 180 n/a PLATES MT20 Weight: 5 lb FT= 20% GRIP 197/144 LUMBER- TOP CHORD2x4SPF No.2BOT CHORD2x4SPF No.2 BRACING- TOP CHORD Structuralwoodsheathing directly applied or 1-1-12 oc purlins.BOT CHORD Rigidceiling directly applied or 10-0-0 oc bracing. MiTekrecommends that Stabilizers and requiredcross bracing beinstalled during truss erection,in accordancewithStabilizer Installation guide.REACTIONS.(lb/size)3=10/Mechanical, 2=136/0-6-0(min. 0-1-8), 4=-3/Mechanical Max Horz2=67(LC 16) Max Uplift3=-14(LC 16), 2=-44(LC 16), 4=-19(LC 22)MaxGrav3=15(LC 30), 2=177(LC 22), 4=15(LC 20) FORCES.(lb)-Max. Comp./Max.Ten.-All forces 250 (lb) orless exceptwhenshown. NOTES- 1)Wind:ASCE 7-10;Vult=115mph(3-second gust)Vasd=91mph;TCDL=6.0psf;BCDL=6.0psf; h=25ft; Cat. II;Exp C; enclosed;MWFRS(envelope) gable end zone and C-CExterior(2)zone;cantileverleft and right exposed ; end verticalleft and right exposed;C-C formembers and forces&MWFRS forreactionsshown; Lumber DOL=1.60 plate grip DOL=1.60 2)TCLL:ASCE 7-10;Pr=20.0 psf(roofliveload: Lumber DOL=1.15Plate DOL=1.15);Pg=20.0 psf(groundsnow);Pf=15.4 psf(flat roofsnow: Lumber DOL=1.15Plate DOL=1.15); CategoryII;Exp C; PartiallyExp.; Ct=1.1 3) Unbalancedsnowloads have been considered for this design. 4)This truss has been designed for greater of minroofliveload of 12.0 psf or 2.00 times flatroofload of 15.4 psf on overhangs non-concurrentwith otherliveloads. 5)This truss has been designed for a 10.0 psf bottomchordliveload nonconcurrentwith any otherliveloads. 6) Refer to girder(s) for truss to trussconnections. 7)Providemechanicalconnection(by others) of truss to bearing platecapable of withstanding 100 lb uplift at joint(s) 3, 2, 4. 8)This trussis designedin accordancewith the 2012 InternationalBuilding Code section 2306.1 and referencedstandardANSI/TPI 1. LOADCASE(S)Standard DE Job # 59223-W1 Dansco Engineering, LLC Date: 6/13/18 WARNING – VERIFY DESIGN PARAMETERS AND READ NOTES BEFORE FABRICATION AND INSTALLATION!!! This truss design is adequate for the design parameters shown. Review and approval of design parameters is the responsibility of the building designer, not the truss designer or truss engineer. Permanent bracing requirements against out-of-plane buckling are noted/shown for individual truss members (and for the truss as a whole) subjected to gravity and wind loads. Additional permanent bracing design shall be the responsibility of the design professional of record. Temporary and erection bracing shall be the responsibility of the contractor. Reference ANSI/TPI-1, “National Design Standard for Metal Plate Connected Wood Truss Construction” and TPI/WTCA BCSI-06, “Building Component Safety Information Guide to Good Practice for Handling, Installing, Restraining and Bracing of Metal Plate Connected Wood Trusses” for additional information. Job 1802242-12T Truss J03 TrussType Jack-OpenGirder Qty 1 Ply 1 1802242-12TDWHWoodside-West Clay- 4 Job Reference (optional)Run:8.200 s Apr72018 Print:8.200 s Apr72018MiTekIndustries,Inc.Tue Jun1221:11:172018 Page1ID:bRTO9oDnRLEHvJjVgeMKW3yF_s1-RRwwj6o3gZYeJrcGIB4jSGAQEjB9ey8Gfi1?Tvz6wH8 Scale=1:23.3 W1 T1 B1 1 2 5 6 7 3 8 4 3x4 2x4 4-5-3 4-4-10 -1-5-9 1-5-9 4-5-3 4-5-3 2 -2 -8 4 -0 -10 0 -4 -7 3 -8 -3 4 -0 -10 4.9912 LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 10.0 SPACING- PlateGrip DOL Lumber DOL RepStressIncr Code 2-0-0 1.15 1.15 NO IBC2012/TPI2007 CSI. TC BC WB Matrix-MR 0.28 0.14 0.00 DEFL. Vert(LL) Vert(TL) Horz(TL) in 0.04 -0.03 -0.10 (loc) 4-5 4-5 3 l/defl >999 >999 n/a L/d 240 180 n/a PLATES MT20 Weight: 14 lb FT= 20% GRIP 197/144 LUMBER- TOP CHORD2x4SPF No.2 BOT CHORD2x4SPF No.2WEBS2x4SPFStud BRACING- TOP CHORD Structuralwoodsheathing directly applied or 4-5-3 oc purlins, except end verticals.BOT CHORD Rigidceiling directly applied or 10-0-0 oc bracing. MiTekrecommends that Stabilizers and requiredcross bracing beinstalled during truss erection,in accordancewithStabilizer Installation guide.REACTIONS.(lb/size)5=155/0-9-11(min. 0-1-8), 3=67/Mechanical, 4=29/Mechanical Max Horz5=86(LC 11) Max Uplift5=-95(LC 16), 3=-78(LC 16), 4=-18(LC 11)MaxGrav5=186(LC 18), 3=79(LC 2), 4=69(LC 7) FORCES.(lb)-Max. Comp./Max.Ten.-All forces 250 (lb) orless exceptwhenshown. NOTES- 1)Wind:ASCE 7-10;Vult=115mph(3-second gust)Vasd=91mph;TCDL=6.0psf;BCDL=6.0psf; h=25ft; Cat. II;Exp C; enclosed;MWFRS(envelope) gable end zone;cantileverleft and right exposed ; end verticalleft and right exposed; Lumber DOL=1.60 plate grip DOL=1.60 2)TCLL:ASCE 7-10;Pr=20.0 psf(roofliveload: Lumber DOL=1.15Plate DOL=1.15);Pg=20.0 psf(groundsnow);Pf=15.4 psf(flat roofsnow: Lumber DOL=1.15Plate DOL=1.15); CategoryII;Exp C; PartiallyExp.; Ct=1.1 3) Unbalancedsnowloads have been considered for this design. 4)This truss has been designed for greater of minroofliveload of 12.0 psf or 2.00 times flatroofload of 15.4 psf on overhangs non-concurrentwith otherliveloads. 5)This truss has been designed for a 10.0 psf bottomchordliveload nonconcurrentwith any otherliveloads. 6) Refer to girder(s) for truss to trussconnections. 7)Providemechanicalconnection(by others) of truss to bearing platecapable of withstanding 100 lb uplift at joint(s) 5, 3, 4. 8)This trussis designedin accordancewith the 2012 InternationalBuilding Code section 2306.1 and referencedstandardANSI/TPI 1. 9) Hanger(s) or otherconnection device(s)shall be providedsufficient to supportconcentratedload(s) 92 lb down and 39 lb up at 2-1-14 on top chord, and 54 lb down and 57 lb up at 2-1-14 on bottomchord.The design/selection of suchconnection device(s)istheresponsibility of others. 10)In the LOAD CASE(S)section,loads applied to the face of the truss are noted as front(F) or back(B). LOADCASE(S)Standard 1) Dead +Snow(balanced): LumberIncrease=1.15,PlateIncrease=1.15 Uniform Loads(plf)Vert: 1-2=-51 Concentrated Loads(lb) Vert: 8=0(F)Trapezoidal Loads(plf) Vert: 2=-2(F=24,B=24)-to-3=-56(F=-3,B=-3), 5=0(F=10,B=10)-to-4=-22(F=-1,B=-1) DE Job # 59223-W1 Dansco Engineering, LLC Date: 6/13/18 WARNING – VERIFY DESIGN PARAMETERS AND READ NOTES BEFORE FABRICATION AND INSTALLATION!!! This truss design is adequate for the design parameters shown. Review and approval of design parameters is the responsibility of the building designer, not the truss designer or truss engineer. Permanent bracing requirements against out-of-plane buckling are noted/shown for individual truss members (and for the truss as a whole) subjected to gravity and wind loads. Additional permanent bracing design shall be the responsibility of the design professional of record. Temporary and erection bracing shall be the responsibility of the contractor. Reference ANSI/TPI-1, “National Design Standard for Metal Plate Connected Wood Truss Construction” and TPI/WTCA BCSI-06, “Building Component Safety Information Guide to Good Practice for Handling, Installing, Restraining and Bracing of Metal Plate Connected Wood Trusses” for additional information. Job 1802242-12T Truss J04 TrussType Jack-Open Qty 1 Ply 1 1802242-12TDWHWoodside-West Clay- 4 Job Reference (optional)Run:8.200 s Apr72018 Print:8.200 s Apr72018MiTekIndustries,Inc.Tue Jun1221:11:182018 Page1ID:bRTO9oDnRLEHvJjVgeMKW3yF_s1-vdUJwSphRtgVx_BSrvcy?Ujbp7XDNPNPuMmZ?Lz6wH7 Scale=1:18.7 W1 T1 B1 1 2 5 3 4 3x4 3x4 1-1-14 1-1-14 -0-9-12 0-9-12 1-1-14 1-1-14 2 -2 -8 3 -0 -14 2 -7 -6 3 -0 -14 9.0012 LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 10.0 SPACING- PlateGrip DOL Lumber DOL RepStressIncr Code 2-0-0 1.15 1.15 YES IBC2012/TPI2007 CSI. TC BC WB Matrix-MR 0.29 0.15 0.00 DEFL. Vert(LL) Vert(TL) Horz(TL) in -0.00 -0.00 -0.02 (loc) 5 5 3 l/defl >999 >999 n/a L/d 240 180 n/a PLATES MT20 Weight: 6 lb FT= 20% GRIP 197/144 LUMBER- TOP CHORD2x4SPF No.2 BOT CHORD2x4SPF No.2WEBS2x4SPFStud BRACING- TOP CHORD Structuralwoodsheathing directly applied or 1-1-14 oc purlins, except end verticals.BOT CHORD Rigidceiling directly applied or 10-0-0 oc bracing. MiTekrecommends that Stabilizers and requiredcross bracing beinstalled during truss erection,in accordancewithStabilizer Installation guide.REACTIONS.(lb/size)5=107/0-6-0(min. 0-1-8), 3=5/Mechanical, 4=7/Mechanical Max Horz5=-74(LC 14) Max Uplift5=-25(LC 14), 3=-52(LC 16), 4=-52(LC 13)MaxGrav5=136(LC 22), 3=45(LC 14), 4=62(LC 14) FORCES.(lb)-Max. Comp./Max.Ten.-All forces 250 (lb) orless exceptwhenshown. NOTES- 1)Wind:ASCE 7-10;Vult=115mph(3-second gust)Vasd=91mph;TCDL=6.0psf;BCDL=6.0psf; h=25ft; Cat. II;Exp C; enclosed;MWFRS(envelope) gable end zone and C-CExterior(2)zone;cantileverleft and right exposed ; end verticalleft and right exposed;C-C formembers and forces&MWFRS forreactionsshown; Lumber DOL=1.60 plate grip DOL=1.60 2)TCLL:ASCE 7-10;Pr=20.0 psf(roofliveload: Lumber DOL=1.15Plate DOL=1.15);Pg=20.0 psf(groundsnow);Pf=15.4 psf(flat roofsnow: Lumber DOL=1.15Plate DOL=1.15); CategoryII;Exp C; PartiallyExp.; Ct=1.1 3) Unbalancedsnowloads have been considered for this design. 4)This truss has been designed for greater of minroofliveload of 12.0 psf or 2.00 times flatroofload of 15.4 psf on overhangs non-concurrentwith otherliveloads. 5)This truss has been designed for a 10.0 psf bottomchordliveload nonconcurrentwith any otherliveloads. 6) Refer to girder(s) for truss to trussconnections. 7)Providemechanicalconnection(by others) of truss to bearing platecapable of withstanding 100 lb uplift at joint(s) 5, 3, 4. 8)This trussis designedin accordancewith the 2012 InternationalBuilding Code section 2306.1 and referencedstandardANSI/TPI 1. LOADCASE(S)Standard DE Job # 59223-W1 Dansco Engineering, LLC Date: 6/13/18 WARNING – VERIFY DESIGN PARAMETERS AND READ NOTES BEFORE FABRICATION AND INSTALLATION!!! This truss design is adequate for the design parameters shown. Review and approval of design parameters is the responsibility of the building designer, not the truss designer or truss engineer. Permanent bracing requirements against out-of-plane buckling are noted/shown for individual truss members (and for the truss as a whole) subjected to gravity and wind loads. Additional permanent bracing design shall be the responsibility of the design professional of record. Temporary and erection bracing shall be the responsibility of the contractor. Reference ANSI/TPI-1, “National Design Standard for Metal Plate Connected Wood Truss Construction” and TPI/WTCA BCSI-06, “Building Component Safety Information Guide to Good Practice for Handling, Installing, Restraining and Bracing of Metal Plate Connected Wood Trusses” for additional information. Job 1802242-12T Truss J05 TrussType Jack-Open Qty 7 Ply 1 1802242-12TDWHWoodside-West Clay- 4 Job Reference (optional)Run:8.200 s Apr72018 Print:8.200 s Apr72018MiTekIndustries,Inc.Tue Jun1221:11:192018 Page1ID:bRTO9oDnRLEHvJjVgeMKW3yF_s1-Np2h8oqJCBoMZ8mfPc7BXhGkQXs_6sdY70W6Xnz6wH6 Scale:1/2"=1' W1 T1 B1 1 2 5 6 3 4 4x4 3x5 2-6-12 2-6-12 -0-9-12 0-9-12 2-6-12 2-6-12 2 -2 -8 4 -1 -9 3 -8 -1 4 -1 -9 9.0012 LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 10.0 SPACING- PlateGrip DOL Lumber DOL RepStressIncr Code 2-0-0 1.15 1.15 YES IBC2012/TPI2007 CSI. TC BC WB Matrix-MR 0.42 0.24 0.00 DEFL. Vert(LL) Vert(TL) Horz(TL) in 0.01 -0.01 -0.06 (loc) 4-5 4-5 3 l/defl >999 >999 n/a L/d 240 180 n/a PLATES MT20 Weight: 10 lb FT= 20% GRIP 197/144 LUMBER- TOP CHORD2x4SPF No.2 BOT CHORD2x4SPF No.2WEBS2x4SPFStud BRACING- TOP CHORD Structuralwoodsheathing directly applied or 2-6-12 oc purlins, except end verticals.BOT CHORD Rigidceiling directly applied or 10-0-0 oc bracing. MiTekrecommends that Stabilizers and requiredcross bracing beinstalled during truss erection,in accordancewithStabilizer Installation guide.REACTIONS.(lb/size)5=142/0-6-0(min. 0-1-8), 3=50/Mechanical, 4=24/Mechanical Max Horz5=96(LC 13) Max Uplift3=-85(LC 16), 4=-24(LC 16)MaxGrav5=163(LC 2), 3=83(LC 30), 4=53(LC 14) FORCES.(lb)-Max. Comp./Max.Ten.-All forces 250 (lb) orless exceptwhenshown. NOTES- 1)Wind:ASCE 7-10;Vult=115mph(3-second gust)Vasd=91mph;TCDL=6.0psf;BCDL=6.0psf; h=25ft; Cat. II;Exp C; enclosed;MWFRS(envelope) gable end zone and C-CExterior(2)-0-9-12 to 2-2-4,Interior(1) 2-2-4 to 2-6-0zone;cantileverleft and right exposed ; end verticalleft and right exposed;C-C formembers and forces&MWFRS forreactionsshown; Lumber DOL=1.60 plate grip DOL=1.60 2)TCLL:ASCE 7-10;Pr=20.0 psf(roofliveload: Lumber DOL=1.15Plate DOL=1.15);Pg=20.0 psf(groundsnow);Pf=15.4 psf(flat roofsnow: Lumber DOL=1.15Plate DOL=1.15); CategoryII;Exp C; PartiallyExp.; Ct=1.1 3) Unbalancedsnowloads have been considered for this design. 4)This truss has been designed for greater of minroofliveload of 12.0 psf or 2.00 times flatroofload of 15.4 psf on overhangs non-concurrentwith otherliveloads. 5)This truss has been designed for a 10.0 psf bottomchordliveload nonconcurrentwith any otherliveloads. 6) Refer to girder(s) for truss to trussconnections. 7)Providemechanicalconnection(by others) of truss to bearing platecapable of withstanding 100 lb uplift at joint(s) 3, 4. 8)This trussis designedin accordancewith the 2012 InternationalBuilding Code section 2306.1 and referencedstandardANSI/TPI 1. LOADCASE(S)Standard DE Job # 59223-W1 Dansco Engineering, LLC Date: 6/13/18 WARNING – VERIFY DESIGN PARAMETERS AND READ NOTES BEFORE FABRICATION AND INSTALLATION!!! This truss design is adequate for the design parameters shown. Review and approval of design parameters is the responsibility of the building designer, not the truss designer or truss engineer. Permanent bracing requirements against out-of-plane buckling are noted/shown for individual truss members (and for the truss as a whole) subjected to gravity and wind loads. Additional permanent bracing design shall be the responsibility of the design professional of record. Temporary and erection bracing shall be the responsibility of the contractor. Reference ANSI/TPI-1, “National Design Standard for Metal Plate Connected Wood Truss Construction” and TPI/WTCA BCSI-06, “Building Component Safety Information Guide to Good Practice for Handling, Installing, Restraining and Bracing of Metal Plate Connected Wood Trusses” for additional information. Job 1802242-12T Truss J06 TrussType Jack-Open Qty 17 Ply 1 1802242-12TDWHWoodside-West Clay- 4 Job Reference (optional)Run:8.200 s Apr72018 Print:8.200 s Apr72018MiTekIndustries,Inc.Tue Jun1221:11:202018 Page1ID:bRTO9oDnRLEHvJjVgeMKW3yF_s1-r0c3L8rxzUwDAILrzKeQ4vozAxDUrJtiLgFf4Ez6wH5 Scale=1:17.9 W1 T1 B1 1 2 5 3 4 2x4 2x4 2-3-12 2-3-12 -0-9-12 0-9-12 2-3-12 2-3-12 1 -2 -8 2 -11 -5 2 -5 -13 2 -11 -5 9.0012 LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 10.0 SPACING- PlateGrip DOL Lumber DOL RepStressIncr Code 2-0-0 1.15 1.15 YES IBC2012/TPI2007 CSI. TC BC WB Matrix-MR 0.17 0.10 0.00 DEFL. Vert(LL) Vert(TL) Horz(TL) in 0.00 -0.00 -0.01 (loc) 4-5 4-5 3 l/defl >999 >999 n/a L/d 240 180 n/a PLATES MT20 Weight: 8 lb FT= 20% GRIP 197/144 LUMBER- TOP CHORD2x4SPF No.2 BOT CHORD2x4SPF No.2WEBS2x4SPFStud BRACING- TOP CHORD Structuralwoodsheathing directly applied or 2-3-12 oc purlins, except end verticals.BOT CHORD Rigidceiling directly applied or 10-0-0 oc bracing. MiTekrecommends that Stabilizers and requiredcross bracing beinstalled during truss erection,in accordancewithStabilizer Installation guide.REACTIONS.(lb/size)5=134/0-6-0(min. 0-1-8), 3=43/Mechanical, 4=20/Mechanical Max Horz5=76(LC 16) Max Uplift3=-61(LC 16), 4=-10(LC 16)MaxGrav5=155(LC 2), 3=64(LC 30), 4=40(LC 7) FORCES.(lb)-Max. Comp./Max.Ten.-All forces 250 (lb) orless exceptwhenshown. NOTES- 1)Wind:ASCE 7-10;Vult=115mph(3-second gust)Vasd=91mph;TCDL=6.0psf;BCDL=6.0psf; h=25ft; Cat. II;Exp C; enclosed;MWFRS(envelope) gable end zone and C-CExterior(2)zone;cantileverleft and right exposed ; end verticalleft and right exposed;C-C formembers and forces&MWFRS forreactionsshown; Lumber DOL=1.60 plate grip DOL=1.60 2)TCLL:ASCE 7-10;Pr=20.0 psf(roofliveload: Lumber DOL=1.15Plate DOL=1.15);Pg=20.0 psf(groundsnow);Pf=15.4 psf(flat roofsnow: Lumber DOL=1.15Plate DOL=1.15); CategoryII;Exp C; PartiallyExp.; Ct=1.1 3) Unbalancedsnowloads have been considered for this design. 4)This truss has been designed for greater of minroofliveload of 12.0 psf or 2.00 times flatroofload of 15.4 psf on overhangs non-concurrentwith otherliveloads. 5)This truss has been designed for a 10.0 psf bottomchordliveload nonconcurrentwith any otherliveloads. 6) Refer to girder(s) for truss to trussconnections. 7)Providemechanicalconnection(by others) of truss to bearing platecapable of withstanding 100 lb uplift at joint(s) 3, 4. 8)This trussis designedin accordancewith the 2012 InternationalBuilding Code section 2306.1 and referencedstandardANSI/TPI 1. LOADCASE(S)Standard DE Job # 59223-W1 Dansco Engineering, LLC Date: 6/13/18 WARNING – VERIFY DESIGN PARAMETERS AND READ NOTES BEFORE FABRICATION AND INSTALLATION!!! This truss design is adequate for the design parameters shown. Review and approval of design parameters is the responsibility of the building designer, not the truss designer or truss engineer. Permanent bracing requirements against out-of-plane buckling are noted/shown for individual truss members (and for the truss as a whole) subjected to gravity and wind loads. Additional permanent bracing design shall be the responsibility of the design professional of record. Temporary and erection bracing shall be the responsibility of the contractor. Reference ANSI/TPI-1, “National Design Standard for Metal Plate Connected Wood Truss Construction” and TPI/WTCA BCSI-06, “Building Component Safety Information Guide to Good Practice for Handling, Installing, Restraining and Bracing of Metal Plate Connected Wood Trusses” for additional information. Job 1802242-12T Truss J07 TrussType Jack-Open Qty 1 Ply 1 1802242-12TDWHWoodside-West Clay- 4 Job Reference (optional)Run:8.200 s Apr72018 Print:8.200 s Apr72018MiTekIndustries,Inc.Tue Jun1221:11:202018 Page1ID:bRTO9oDnRLEHvJjVgeMKW3yF_s1-r0c3L8rxzUwDAILrzKeQ4vo_BxELrJtiLgFf4Ez6wH5 Scale=1:12.5 W1 T1 B1 1 2 5 3 4 1.5x4 1.5x4 0-10-14 0-10-14 -0-9-12 0-9-12 0-10-14 0-10-14 1 -2 -8 1 -10 -10 1 -5 -2 1 -10 -10 9.0012 LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 10.0 SPACING- PlateGrip DOL Lumber DOL RepStressIncr Code 2-0-0 1.15 1.15 YES IBC2012/TPI2007 CSI. TC BC WB Matrix-MR 0.10 0.04 0.00 DEFL. Vert(LL) Vert(TL) Horz(TL) in -0.00 -0.00 -0.00 (loc) 5 5 3 l/defl >999 >999 n/a L/d 240 180 n/a PLATES MT20 Weight: 5 lb FT= 20% GRIP 197/144 LUMBER- TOP CHORD2x4SPF No.2 BOT CHORD2x4SPF No.2WEBS2x4SPFStud BRACING- TOP CHORD Structuralwoodsheathing directly applied or 0-10-14 oc purlins, except end verticals.BOT CHORD Rigidceiling directly applied or 10-0-0 oc bracing. MiTekrecommends that Stabilizers and requiredcross bracing beinstalled during truss erection,in accordancewithStabilizer Installation guide.REACTIONS.(lb/size)5=106/0-6-0(min. 0-1-8), 3=-6/Mechanical, 4=2/Mechanical Max Horz5=47(LC 13) Max Uplift3=-33(LC 22), 4=-21(LC 13)MaxGrav5=143(LC 22), 3=15(LC 14), 4=26(LC 14) FORCES.(lb)-Max. Comp./Max.Ten.-All forces 250 (lb) orless exceptwhenshown. NOTES- 1)Wind:ASCE 7-10;Vult=115mph(3-second gust)Vasd=91mph;TCDL=6.0psf;BCDL=6.0psf; h=25ft; Cat. II;Exp C; enclosed;MWFRS(envelope) gable end zone and C-CExterior(2)zone;cantileverleft and right exposed ; end verticalleft and right exposed;C-C formembers and forces&MWFRS forreactionsshown; Lumber DOL=1.60 plate grip DOL=1.60 2)TCLL:ASCE 7-10;Pr=20.0 psf(roofliveload: Lumber DOL=1.15Plate DOL=1.15);Pg=20.0 psf(groundsnow);Pf=15.4 psf(flat roofsnow: Lumber DOL=1.15Plate DOL=1.15); CategoryII;Exp C; PartiallyExp.; Ct=1.1 3) Unbalancedsnowloads have been considered for this design. 4)This truss has been designed for greater of minroofliveload of 12.0 psf or 2.00 times flatroofload of 15.4 psf on overhangs non-concurrentwith otherliveloads. 5)This truss has been designed for a 10.0 psf bottomchordliveload nonconcurrentwith any otherliveloads. 6) Refer to girder(s) for truss to trussconnections. 7)Providemechanicalconnection(by others) of truss to bearing platecapable of withstanding 100 lb uplift at joint(s) 3, 4. 8)This trussis designedin accordancewith the 2012 InternationalBuilding Code section 2306.1 and referencedstandardANSI/TPI 1. LOADCASE(S)Standard DE Job # 59223-W1 Dansco Engineering, LLC Date: 6/13/18 WARNING – VERIFY DESIGN PARAMETERS AND READ NOTES BEFORE FABRICATION AND INSTALLATION!!! This truss design is adequate for the design parameters shown. Review and approval of design parameters is the responsibility of the building designer, not the truss designer or truss engineer. Permanent bracing requirements against out-of-plane buckling are noted/shown for individual truss members (and for the truss as a whole) subjected to gravity and wind loads. Additional permanent bracing design shall be the responsibility of the design professional of record. Temporary and erection bracing shall be the responsibility of the contractor. Reference ANSI/TPI-1, “National Design Standard for Metal Plate Connected Wood Truss Construction” and TPI/WTCA BCSI-06, “Building Component Safety Information Guide to Good Practice for Handling, Installing, Restraining and Bracing of Metal Plate Connected Wood Trusses” for additional information. Job 1802242-12T Truss J08 TrussType Jack-OpenGirder Qty 1 Ply 1 1802242-12TDWHWoodside-West Clay- 4 Job Reference (optional)Run:8.200 s Apr72018 Print:8.200 s Apr72018MiTekIndustries,Inc.Tue Jun1221:11:212018 Page1ID:bRTO9oDnRLEHvJjVgeMKW3yF_s1-JC9RZUsZko24oSv1X19fd6L7sKZgam7raK?Dcgz6wH4 Scale=1:17.3 W1 T1 B1 1 2 5 6 7 3 8 4 2x4 2x4 3-11-12 3-11-12 -1-5-9 1-5-9 3-11-12 3-11-12 1 -2 -8 2 -10 -6 2 -5 -15 2 -10 -6 4.9912 LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 10.0 SPACING- PlateGrip DOL Lumber DOL RepStressIncr Code 2-0-0 1.15 1.15 NO IBC2012/TPI2007 CSI. TC BC WB Matrix-MR 0.23 0.10 0.00 DEFL. Vert(LL) Vert(TL) Horz(TL) in 0.02 -0.01 -0.03 (loc) 4-5 4-5 3 l/defl >999 >999 n/a L/d 240 180 n/a PLATES MT20 Weight: 12 lb FT= 20% GRIP 197/144 LUMBER- TOP CHORD2x4SPF No.2 BOT CHORD2x4SPF No.2WEBS2x4SPFStud BRACING- TOP CHORD Structuralwoodsheathing directly applied or 3-11-12 oc purlins, except end verticals.BOT CHORD Rigidceiling directly applied or 10-0-0 oc bracing. MiTekrecommends that Stabilizers and requiredcross bracing beinstalled during truss erection,in accordancewithStabilizer Installation guide.REACTIONS.(lb/size)5=130/0-9-11(min. 0-1-8), 3=42/Mechanical, 4=19/Mechanical Max Horz5=74(LC 11) Max Uplift5=-105(LC 16), 3=-75(LC 16), 4=-3(LC 16)MaxGrav5=170(LC 18), 3=51(LC 2), 4=55(LC 7) FORCES.(lb)-Max. Comp./Max.Ten.-All forces 250 (lb) orless exceptwhenshown. NOTES- 1)Wind:ASCE 7-10;Vult=115mph(3-second gust)Vasd=91mph;TCDL=6.0psf;BCDL=6.0psf; h=25ft; Cat. II;Exp C; enclosed;MWFRS(envelope) gable end zone;cantileverleft and right exposed ; end verticalleft and right exposed; Lumber DOL=1.60 plate grip DOL=1.60 2)TCLL:ASCE 7-10;Pr=20.0 psf(roofliveload: Lumber DOL=1.15Plate DOL=1.15);Pg=20.0 psf(groundsnow);Pf=15.4 psf(flat roofsnow: Lumber DOL=1.15Plate DOL=1.15); CategoryII;Exp C; PartiallyExp.; Ct=1.1 3) Unbalancedsnowloads have been considered for this design. 4)This truss has been designed for greater of minroofliveload of 12.0 psf or 2.00 times flatroofload of 15.4 psf on overhangs non-concurrentwith otherliveloads. 5)This truss has been designed for a 10.0 psf bottomchordliveload nonconcurrentwith any otherliveloads. 6) Refer to girder(s) for truss to trussconnections. 7)Providemechanicalconnection(by others) of truss to bearing platecapable of withstanding 100 lb uplift at joint(s) 3, 4 except(jt=lb) 5=105. 8)This trussis designedin accordancewith the 2012 InternationalBuilding Code section 2306.1 and referencedstandardANSI/TPI 1. 9) Hanger(s) or otherconnection device(s)shall be providedsufficient to supportconcentratedload(s) 57 lb down and 80 lb up at 1-8-7 on top chord, and 21 lb down and 24 lb up at 1-8-7 on bottomchord.The design/selection of suchconnection device(s)is the responsibility of others. 10)In the LOAD CASE(S)section,loads applied to the face of the truss are noted as front(F) or back(B). LOADCASE(S)Standard 1) Dead +Snow(balanced): LumberIncrease=1.15,PlateIncrease=1.15Uniform Loads(plf) Vert: 1-2=-51 Concentrated Loads(lb)Vert: 6=26(B) 8=1(B) Trapezoidal Loads(plf) Vert: 2=-2(F=24,B=24)-to-3=-51(F=0,B=0), 5=0(F=10,B=10)-to-4=-20(F=0,B=0) DE Job # 59223-W1 Dansco Engineering, LLC Date: 6/13/18 WARNING – VERIFY DESIGN PARAMETERS AND READ NOTES BEFORE FABRICATION AND INSTALLATION!!! This truss design is adequate for the design parameters shown. Review and approval of design parameters is the responsibility of the building designer, not the truss designer or truss engineer. Permanent bracing requirements against out-of-plane buckling are noted/shown for individual truss members (and for the truss as a whole) subjected to gravity and wind loads. Additional permanent bracing design shall be the responsibility of the design professional of record. Temporary and erection bracing shall be the responsibility of the contractor. Reference ANSI/TPI-1, “National Design Standard for Metal Plate Connected Wood Truss Construction” and TPI/WTCA BCSI-06, “Building Component Safety Information Guide to Good Practice for Handling, Installing, Restraining and Bracing of Metal Plate Connected Wood Trusses” for additional information. Job 1802242-12T Truss J09 TrussType Jack-OpenGirder Qty 1 Ply 1 1802242-12TDWHWoodside-West Clay- 4 Job Reference (optional)Run:8.200 s Apr72018 Print:8.200 s Apr72018MiTekIndustries,Inc.Tue Jun1221:11:222018 Page1ID:bRTO9oDnRLEHvJjVgeMKW3yF_s1-nOjpmqsBV6AxQcUE4kgu9KuK4kwzJDN?p_km86z6wH3 Scale=1:12.5 W1 T1 B1 1 4 2 3 1.5x4 1.5x4 2-6-10 2-6-10 2-6-10 2-6-10 1 -1 -1 1 -10 -14 1 -6 -12 1 -10 -14 3.8412 LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 10.0 SPACING- PlateGrip DOL Lumber DOL RepStressIncr Code 2-0-0 1.15 1.15 NO IBC2012/TPI2007 CSI. TC BC WB Matrix-MR 0.08 0.03 0.00 DEFL. Vert(LL) Vert(TL) Horz(TL) in -0.00 -0.00 -0.01 (loc) 3-4 3-4 2 l/defl >999 >999 n/a L/d 240 180 n/a PLATES MT20 Weight: 7 lb FT= 20% GRIP 197/144 LUMBER- TOP CHORD2x4SPF No.2 BOT CHORD2x4SPF No.2WEBS2x4SPFStud BRACING- TOP CHORD Structuralwoodsheathing directly applied or 2-6-10 oc purlins, except end verticals.BOT CHORD Rigidceiling directly applied or 10-0-0 oc bracing. MiTekrecommends that Stabilizers and requiredcross bracing beinstalled during truss erection,in accordancewithStabilizer Installation guide.REACTIONS.(lb/size)4=20/0-8-8(min. 0-1-8), 2=27/Mechanical, 3=12/Mechanical Max Horz4=37(LC 11) Max Uplift4=-38(LC 10), 2=-50(LC 16)MaxGrav4=34(LC 7), 2=32(LC 2), 3=33(LC 7) FORCES.(lb)-Max. Comp./Max.Ten.-All forces 250 (lb) orless exceptwhenshown. NOTES- 1)Wind:ASCE 7-10;Vult=115mph(3-second gust)Vasd=91mph;TCDL=6.0psf;BCDL=6.0psf; h=25ft; Cat. II;Exp C; enclosed;MWFRS(envelope) gable end zone;cantileverleft and right exposed ; end verticalleft and right exposed; Lumber DOL=1.60 plate grip DOL=1.60 2)TCLL:ASCE 7-10;Pr=20.0 psf(roofliveload: Lumber DOL=1.15Plate DOL=1.15);Pg=20.0 psf(groundsnow);Pf=15.4 psf(flat roofsnow: Lumber DOL=1.15Plate DOL=1.15); CategoryII;Exp C; PartiallyExp.; Ct=1.1 3) Unbalancedsnowloads have been considered for this design. 4)This truss has been designed for a 10.0 psf bottomchordliveload nonconcurrentwith any otherliveloads. 5) Refer to girder(s) for truss to trussconnections. 6)Providemechanicalconnection(by others) of truss to bearing platecapable of withstanding 100 lb uplift at joint(s) 4, 2. 7)This trussis designedin accordancewith the 2012 InternationalBuilding Code section 2306.1 and referencedstandardANSI/TPI 1. 8)In the LOAD CASE(S)section,loads applied to the face of the truss are noted as front(F) or back(B). LOADCASE(S)Standard 1) Dead +Snow(balanced): LumberIncrease=1.15,PlateIncrease=1.15Trapezoidal Loads(plf) Vert: 1=0(F=25,B=25)-to-2=-36(F=7,B=7), 4=0(F=10,B=10)-to-3=-14(F=3,B=3) DE Job # 59223-W1 Dansco Engineering, LLC Date: 6/13/18 WARNING – VERIFY DESIGN PARAMETERS AND READ NOTES BEFORE FABRICATION AND INSTALLATION!!! This truss design is adequate for the design parameters shown. Review and approval of design parameters is the responsibility of the building designer, not the truss designer or truss engineer. Permanent bracing requirements against out-of-plane buckling are noted/shown for individual truss members (and for the truss as a whole) subjected to gravity and wind loads. Additional permanent bracing design shall be the responsibility of the design professional of record. Temporary and erection bracing shall be the responsibility of the contractor. Reference ANSI/TPI-1, “National Design Standard for Metal Plate Connected Wood Truss Construction” and TPI/WTCA BCSI-06, “Building Component Safety Information Guide to Good Practice for Handling, Installing, Restraining and Bracing of Metal Plate Connected Wood Trusses” for additional information. Job 1802242-12T Truss J10 TrussType Jack-Open Qty 1 Ply 1 1802242-12TDWHWoodside-West Clay- 4 Job Reference (optional)Run:8.200 s Apr72018 Print:8.200 s Apr72018MiTekIndustries,Inc.Tue Jun1221:11:232018 Page1ID:bRTO9oDnRLEHvJjVgeMKW3yF_s1-FbHC_AtpGPIo1m3QeSB7iXQVh8G?2gd81eUKgYz6wH2 Scale=1:12.3 W1 T1 B1 1 4 2 3 3x8 2-1-0 2-1-0 2-1-0 2-1-0 0 -10 -0 1 -10 -8 1 -5 -14 1 -10 -8 6.0012 LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 10.0 SPACING- PlateGrip DOL Lumber DOL RepStressIncr Code 2-0-0 1.15 1.15 YES IBC2012/TPI2007 CSI. TC BC WB Matrix-MR 0.09 0.05 0.00 DEFL. Vert(LL) Vert(TL) Horz(TL) in -0.00 -0.00 -0.00 (loc) 4 3-4 2 l/defl >999 >999 n/a L/d 240 180 n/a PLATES MT20 Weight: 6 lb FT= 20% GRIP 197/144 LUMBER- TOP CHORD2x4SPF No.2 BOT CHORD2x4SPF No.2WEBS2x4SPFStud BRACING- TOP CHORD Structuralwoodsheathing directly applied or 2-1-0 oc purlins, except end verticals.BOT CHORD Rigidceiling directly applied or 10-0-0 oc bracing. MiTekrecommends that Stabilizers and requiredcross bracing beinstalled during truss erection,in accordancewithStabilizer Installation guide.REACTIONS.(lb/size)4=66/0-6-0(min. 0-1-8), 2=45/Mechanical, 3=21/Mechanical Max Horz4=36(LC 13) Max Uplift2=-38(LC 16)MaxGrav4=75(LC 2), 2=53(LC 2), 3=36(LC 7) FORCES.(lb)-Max. Comp./Max.Ten.-All forces 250 (lb) orless exceptwhenshown. NOTES- 1)Wind:ASCE 7-10;Vult=115mph(3-second gust)Vasd=91mph;TCDL=6.0psf;BCDL=6.0psf; h=25ft; Cat. II;Exp C; enclosed;MWFRS(envelope) gable end zone and C-CExterior(2)zone;cantileverleft and right exposed ; end verticalleft and right exposed;C-C formembers and forces&MWFRS forreactionsshown; Lumber DOL=1.60 plate grip DOL=1.60 2)TCLL:ASCE 7-10;Pr=20.0 psf(roofliveload: Lumber DOL=1.15Plate DOL=1.15);Pg=20.0 psf(groundsnow);Pf=15.4 psf(flat roofsnow: Lumber DOL=1.15Plate DOL=1.15); CategoryII;Exp C; PartiallyExp.; Ct=1.1 3) Unbalancedsnowloads have been considered for this design. 4)This truss has been designed for a 10.0 psf bottomchordliveload nonconcurrentwith any otherliveloads. 5) Refer to girder(s) for truss to trussconnections. 6)Providemechanicalconnection(by others) of truss to bearing platecapable of withstanding 100 lb uplift at joint(s) 2. 7)This trussis designedin accordancewith the 2012 InternationalBuilding Code section 2306.1 and referencedstandardANSI/TPI 1. LOADCASE(S)Standard DE Job # 59223-W1 Dansco Engineering, LLC Date: 6/13/18 WARNING – VERIFY DESIGN PARAMETERS AND READ NOTES BEFORE FABRICATION AND INSTALLATION!!! This truss design is adequate for the design parameters shown. Review and approval of design parameters is the responsibility of the building designer, not the truss designer or truss engineer. Permanent bracing requirements against out-of-plane buckling are noted/shown for individual truss members (and for the truss as a whole) subjected to gravity and wind loads. Additional permanent bracing design shall be the responsibility of the design professional of record. Temporary and erection bracing shall be the responsibility of the contractor. Reference ANSI/TPI-1, “National Design Standard for Metal Plate Connected Wood Truss Construction” and TPI/WTCA BCSI-06, “Building Component Safety Information Guide to Good Practice for Handling, Installing, Restraining and Bracing of Metal Plate Connected Wood Trusses” for additional information. Job 1802242-12T Truss J11 TrussType Jack-OpenGirder Qty 1 Ply 1 1802242-12TDWHWoodside-West Clay- 4 Job Reference (optional)Run:8.200 s Apr72018 Print:8.200 s Apr72018MiTekIndustries,Inc.Tue Jun1221:11:242018 Page1ID:bRTO9oDnRLEHvJjVgeMKW3yF_s1-jnraBWuS1jQffvecC9iMElzczYYnn7tHGIDtD?z6wH1 Scale=1:19.6 W1 T1 B1 1 4 5 6 2 7 3 3x8 5-7-15 5-7-15 2-9-15 2-9-15 5-7-15 2-9-15 0 -9 -12 3 -2 -0 0 -4 -7 2 -9 -9 3 -2 -0 4.9912 LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 10.0 SPACING- PlateGrip DOL Lumber DOL RepStressIncr Code 2-0-0 1.15 1.15 NO IBC2012/TPI2007 CSI. TC BC WB Matrix-MR 0.37 0.27 0.00 DEFL. Vert(LL) Vert(TL) Horz(TL) in 0.05 -0.10 0.03 (loc) 3-4 3-4 2 l/defl >999 >669 n/a L/d 240 180 n/a PLATES MT20 Weight: 14 lb FT= 20% GRIP 197/144 LUMBER- TOP CHORD2x4SPF No.2 BOT CHORD2x4SPF No.2WEBS2x4SPFStud BRACING- TOP CHORD Structuralwoodsheathing directly applied or 5-7-15 oc purlins, except end verticals.BOT CHORD Rigidceiling directly applied or 10-0-0 oc bracing. MiTekrecommends that Stabilizers and requiredcross bracing beinstalled during truss erection,in accordancewithStabilizer Installation guide.REACTIONS.(lb/size)4=92/0-6-11(min. 0-1-8), 2=124/Mechanical, 3=59/Mechanical Max Horz4=74(LC 16) Max Uplift4=-64(LC 16), 2=-85(LC 12)MaxGrav4=107(LC 7), 2=146(LC 2), 3=101(LC 7) FORCES.(lb)-Max. Comp./Max.Ten.-All forces 250 (lb) orless exceptwhenshown. NOTES- 1)Wind:ASCE 7-10;Vult=115mph(3-second gust)Vasd=91mph;TCDL=6.0psf;BCDL=6.0psf; h=25ft; Cat. II;Exp C; enclosed;MWFRS(envelope) gable end zone;cantileverleft and right exposed ; end verticalleft and right exposed; Lumber DOL=1.60 plate grip DOL=1.60 2)TCLL:ASCE 7-10;Pr=20.0 psf(roofliveload: Lumber DOL=1.15Plate DOL=1.15);Pg=20.0 psf(groundsnow);Pf=15.4 psf(flat roofsnow: Lumber DOL=1.15Plate DOL=1.15); CategoryII;Exp C; PartiallyExp.; Ct=1.1 3) Unbalancedsnowloads have been considered for this design. 4)This truss has been designed for a 10.0 psf bottomchordliveload nonconcurrentwith any otherliveloads. 5) Refer to girder(s) for truss to trussconnections. 6)Providemechanicalconnection(by others) of truss to bearing platecapable of withstanding 100 lb uplift at joint(s) 4, 2. 7)This trussis designedin accordancewith the 2012 InternationalBuilding Code section 2306.1 and referencedstandardANSI/TPI 1. 8) Hanger(s) or otherconnection device(s)shall be providedsufficient to supportconcentratedload(s) 18 lb down and 28 lb up at 2-7-7 on top chord, and 3 lb down at 2-7-7 on bottomchord.The design/selection of suchconnection device(s)is the responsibility of others. 9)In the LOAD CASE(S)section,loads applied to the face of the truss are noted as front(F) or back(B). LOADCASE(S)Standard 1) Dead +Snow(balanced): LumberIncrease=1.15,PlateIncrease=1.15Concentrated Loads(lb) Vert: 7=-2(F) Trapezoidal Loads(plf)Vert: 1=0(F=25,B=25)-to-2=-72(F=-11,B=-11), 4=0(F=10,B=10)-to-3=-28(F=-4,B=-4) DE Job # 59223-W1 Dansco Engineering, LLC Date: 6/13/18 WARNING – VERIFY DESIGN PARAMETERS AND READ NOTES BEFORE FABRICATION AND INSTALLATION!!! This truss design is adequate for the design parameters shown. Review and approval of design parameters is the responsibility of the building designer, not the truss designer or truss engineer. Permanent bracing requirements against out-of-plane buckling are noted/shown for individual truss members (and for the truss as a whole) subjected to gravity and wind loads. Additional permanent bracing design shall be the responsibility of the design professional of record. Temporary and erection bracing shall be the responsibility of the contractor. Reference ANSI/TPI-1, “National Design Standard for Metal Plate Connected Wood Truss Construction” and TPI/WTCA BCSI-06, “Building Component Safety Information Guide to Good Practice for Handling, Installing, Restraining and Bracing of Metal Plate Connected Wood Trusses” for additional information. Job 1802242-12T Truss J12 TrussType Jack-OpenGirder Qty 1 Ply 1 1802242-12TDWHWoodside-West Clay- 4 Job Reference (optional)Run:8.200 s Apr72018 Print:8.200 s Apr72018MiTekIndustries,Inc.Tue Jun1221:11:252018 Page1ID:bRTO9oDnRLEHvJjVgeMKW3yF_s1-CzPyOrv4o1YWH3DpltEbnyVfcyqjWa6RVyzQlRz6wH0 Scale=1:25.7 W1 T1 B1 1 2 5 6 7 3 8 9 4 4x4 3x4 3-8-3 3-8-3 7-4-5 3-8-3 -1-7-6 1-7-6 3-8-3 3-8-3 7-4-5 3-8-3 1 -3 -4 4 -4 -0 3 -11 -9 4 -4 -0 4.9912 LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 10.0 SPACING- PlateGrip DOL Lumber DOL RepStressIncr Code 2-0-0 1.15 1.15 NO IBC2012/TPI2007 CSI. TC BC WB Matrix-MR 0.83 0.54 0.00 DEFL. Vert(LL) Vert(TL) Horz(TL) in 0.18 -0.33 0.13 (loc) 4-5 4-5 3 l/defl >479 >260 n/a L/d 240 180 n/a PLATES MT20 Weight: 21 lb FT= 20% GRIP 197/144 LUMBER- TOP CHORD2x4SPF No.2 BOT CHORD2x4SPF No.2WEBS2x4SPFStud BRACING- TOP CHORD Structuralwoodsheathing directly applied or 6-0-0 oc purlins, except end verticals.BOT CHORD Rigidceiling directly applied or 10-0-0 oc bracing. MiTekrecommends that Stabilizers and requiredcross bracing beinstalled during truss erection,in accordancewithStabilizer Installation guide.REACTIONS.(lb/size)5=260/0-9-11(min. 0-1-8), 3=208/Mechanical, 4=95/Mechanical Max Horz5=124(LC 12) Max Uplift5=-109(LC 16), 3=-183(LC 12)MaxGrav5=299(LC 2), 3=244(LC 2), 4=152(LC 7) FORCES.(lb)-Max. Comp./Max.Ten.-All forces 250 (lb) orless exceptwhenshown.TOP CHORD 2-5=-264/152 NOTES-1)Wind:ASCE 7-10;Vult=115mph(3-second gust)Vasd=91mph;TCDL=6.0psf;BCDL=6.0psf; h=25ft; Cat. II;Exp C; enclosed; MWFRS(envelope) gable end zone;cantileverleft and right exposed ; end verticalleft and right exposed; Lumber DOL=1.60 plate grip DOL=1.60 2)TCLL:ASCE 7-10;Pr=20.0 psf(roofliveload: Lumber DOL=1.15Plate DOL=1.15);Pg=20.0 psf(groundsnow);Pf=15.4 psf(flat roofsnow: Lumber DOL=1.15Plate DOL=1.15); CategoryII;Exp C; PartiallyExp.; Ct=1.1 3) Unbalancedsnowloads have been considered for this design. 4)This truss has been designed for greater of minroofliveload of 12.0 psf or 2.00 times flatroofload of 15.4 psf on overhangs non-concurrentwith otherliveloads. 5)This truss has been designed for a 10.0 psf bottomchordliveload nonconcurrentwith any otherliveloads. 6) Refer to girder(s) for truss to trussconnections. 7)Providemechanicalconnection(by others) of truss to bearing platecapable of withstanding 100 lb uplift at joint(s) except(jt=lb) 5=109, 3=183. 8)This trussis designedin accordancewith the 2012 InternationalBuilding Code section 2306.1 and referencedstandardANSI/TPI 1.9) Hanger(s) or otherconnection device(s)shall be providedsufficient to supportconcentratedload(s) 75 lb down and 31 lb up at 2-8-3, and 93 lb down and 73 lb up at 5-1-0 on top chord, and 16 lb down and 22 lb up at 2-8-3, and 23 lb down and 24 lb up at 5-1-0 on bottomchord.The design/selection of suchconnection device(s)is the responsibility of others.10)In the LOAD CASE(S)section,loads applied to the face of the truss are noted as front(F) or back(B). LOADCASE(S)Standard1) Dead +Snow(balanced): LumberIncrease=1.15,PlateIncrease=1.15 Uniform Loads(plf) Vert: 1-2=-51Concentrated Loads(lb) Vert: 8=0(B) 9=-2(B) Continued on page 2 DE Job # 59223-W1 Dansco Engineering, LLC Date: 6/13/18 WARNING – VERIFY DESIGN PARAMETERS AND READ NOTES BEFORE FABRICATION AND INSTALLATION!!! This truss design is adequate for the design parameters shown. Review and approval of design parameters is the responsibility of the building designer, not the truss designer or truss engineer. Permanent bracing requirements against out-of-plane buckling are noted/shown for individual truss members (and for the truss as a whole) subjected to gravity and wind loads. Additional permanent bracing design shall be the responsibility of the design professional of record. Temporary and erection bracing shall be the responsibility of the contractor. Reference ANSI/TPI-1, “National Design Standard for Metal Plate Connected Wood Truss Construction” and TPI/WTCA BCSI-06, “Building Component Safety Information Guide to Good Practice for Handling, Installing, Restraining and Bracing of Metal Plate Connected Wood Trusses” for additional information. Job 1802242-12T Truss J12 TrussType Jack-OpenGirder Qty 1 Ply 1 1802242-12TDWHWoodside-West Clay- 4 Job Reference (optional)Run:8.200 s Apr72018 Print:8.200 s Apr72018MiTekIndustries,Inc.Tue Jun1221:11:252018 Page2ID:bRTO9oDnRLEHvJjVgeMKW3yF_s1-CzPyOrv4o1YWH3DpltEbnyVfcyqjWa6RVyzQlRz6wH0 LOADCASE(S)Standard Trapezoidal Loads(plf) Vert: 2=-2(F=24,B=24)-to-3=-93(F=-21,B=-21), 5=0(F=10,B=10)-to-4=-37(F=-8,B=-8) DE Job # 59223-W1 Dansco Engineering, LLC Date: 6/13/18 WARNING – VERIFY DESIGN PARAMETERS AND READ NOTES BEFORE FABRICATION AND INSTALLATION!!! This truss design is adequate for the design parameters shown. Review and approval of design parameters is the responsibility of the building designer, not the truss designer or truss engineer. Permanent bracing requirements against out-of-plane buckling are noted/shown for individual truss members (and for the truss as a whole) subjected to gravity and wind loads. Additional permanent bracing design shall be the responsibility of the design professional of record. Temporary and erection bracing shall be the responsibility of the contractor. Reference ANSI/TPI-1, “National Design Standard for Metal Plate Connected Wood Truss Construction” and TPI/WTCA BCSI-06, “Building Component Safety Information Guide to Good Practice for Handling, Installing, Restraining and Bracing of Metal Plate Connected Wood Trusses” for additional information. Job 1802242-12T Truss J13 TrussType Jack-Open Qty 1 Ply 1 1802242-12TDWHWoodside-West Clay- 4 Job Reference (optional)Run:8.200 s Apr72018 Print:8.200 s Apr72018MiTekIndustries,Inc.Tue Jun1221:11:262018 Page1ID:bRTO9oDnRLEHvJjVgeMKW3yF_s1-gAzKcBviYKgNuDo?JalqJA2_BLGMF1Makci_Htz6wH? Scale=1:14.9 W1 T1 B1 1 2 5 3 4 2x4 2x4 1-5-6 1-5-6 -0-10-12 0-10-12 1-5-6 1-5-6 1 -3 -4 2 -4 -4 1 -10 -12 2 -4 -4 9.0012 LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 10.0 SPACING- PlateGrip DOL Lumber DOL RepStressIncr Code 2-0-0 1.15 1.15 YES IBC2012/TPI2007 CSI. TC BC WB Matrix-MR 0.13 0.07 0.00 DEFL. Vert(LL) Vert(TL) Horz(TL) in -0.00 -0.00 -0.01 (loc) 5 5 3 l/defl >999 >999 n/a L/d 240 180 n/a PLATES MT20 Weight: 6 lb FT= 20% GRIP 197/144 LUMBER- TOP CHORD2x4SPF No.2 BOT CHORD2x4SPF No.2WEBS2x4SPFStud BRACING- TOP CHORD Structuralwoodsheathing directly applied or 1-5-6 oc purlins, except end verticals.BOT CHORD Rigidceiling directly applied or 10-0-0 oc bracing. MiTekrecommends that Stabilizers and requiredcross bracing beinstalled during truss erection,in accordancewithStabilizer Installation guide.REACTIONS.(lb/size)5=120/0-6-0(min. 0-1-8), 3=15/Mechanical, 4=9/Mechanical Max Horz5=59(LC 13) Max Uplift3=-41(LC 16), 4=-15(LC 16)MaxGrav5=145(LC 22), 3=32(LC 30), 4=27(LC 14) FORCES.(lb)-Max. Comp./Max.Ten.-All forces 250 (lb) orless exceptwhenshown. NOTES- 1)Wind:ASCE 7-10;Vult=115mph(3-second gust)Vasd=91mph;TCDL=6.0psf;BCDL=6.0psf; h=25ft; Cat. II;Exp C; enclosed;MWFRS(envelope) gable end zone and C-CExterior(2)zone;cantileverleft and right exposed ; end verticalleft and right exposed;C-C formembers and forces&MWFRS forreactionsshown; Lumber DOL=1.60 plate grip DOL=1.60 2)TCLL:ASCE 7-10;Pr=20.0 psf(roofliveload: Lumber DOL=1.15Plate DOL=1.15);Pg=20.0 psf(groundsnow);Pf=15.4 psf(flat roofsnow: Lumber DOL=1.15Plate DOL=1.15); CategoryII;Exp C; PartiallyExp.; Ct=1.1 3) Unbalancedsnowloads have been considered for this design. 4)This truss has been designed for greater of minroofliveload of 12.0 psf or 2.00 times flatroofload of 15.4 psf on overhangs non-concurrentwith otherliveloads. 5)This truss has been designed for a 10.0 psf bottomchordliveload nonconcurrentwith any otherliveloads. 6) Refer to girder(s) for truss to trussconnections. 7)Providemechanicalconnection(by others) of truss to bearing platecapable of withstanding 100 lb uplift at joint(s) 3, 4. 8)This trussis designedin accordancewith the 2012 InternationalBuilding Code section 2306.1 and referencedstandardANSI/TPI 1. LOADCASE(S)Standard DE Job # 59223-W1 Dansco Engineering, LLC Date: 6/13/18 WARNING – VERIFY DESIGN PARAMETERS AND READ NOTES BEFORE FABRICATION AND INSTALLATION!!! This truss design is adequate for the design parameters shown. Review and approval of design parameters is the responsibility of the building designer, not the truss designer or truss engineer. Permanent bracing requirements against out-of-plane buckling are noted/shown for individual truss members (and for the truss as a whole) subjected to gravity and wind loads. Additional permanent bracing design shall be the responsibility of the design professional of record. Temporary and erection bracing shall be the responsibility of the contractor. Reference ANSI/TPI-1, “National Design Standard for Metal Plate Connected Wood Truss Construction” and TPI/WTCA BCSI-06, “Building Component Safety Information Guide to Good Practice for Handling, Installing, Restraining and Bracing of Metal Plate Connected Wood Trusses” for additional information. Job 1802242-12T Truss J14 TrussType Jack-Open Qty 1 Ply 1 1802242-12TDWHWoodside-West Clay- 4 Job Reference (optional)Run:8.200 s Apr72018 Print:8.200 s Apr72018MiTekIndustries,Inc.Tue Jun1221:11:272018 Page1ID:bRTO9oDnRLEHvJjVgeMKW3yF_s1-8MXipXwKJeoDWNNBtIG3sNb8flbb_UckyGSXpKz6wH_ Scale=1:19.9 W1 T1 B1 1 2 5 6 3 4 3x4 2x4 2-9-6 2-9-6 -0-10-12 0-10-12 2-9-6 2-9-6 1 -3 -4 3 -4 -4 2 -10 -12 3 -4 -4 9.0012 LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 10.0 SPACING- PlateGrip DOL Lumber DOL RepStressIncr Code 2-0-0 1.15 1.15 YES IBC2012/TPI2007 CSI. TC BC WB Matrix-MR 0.21 0.13 0.00 DEFL. Vert(LL) Vert(TL) Horz(TL) in 0.01 -0.01 -0.02 (loc) 4-5 4-5 3 l/defl >999 >999 n/a L/d 240 180 n/a PLATES MT20 Weight: 10 lb FT= 20% GRIP 197/144 LUMBER- TOP CHORD2x4SPF No.2 BOT CHORD2x4SPF No.2WEBS2x4SPFStud BRACING- TOP CHORD Structuralwoodsheathing directly applied or 2-9-6 oc purlins, except end verticals.BOT CHORD Rigidceiling directly applied or 10-0-0 oc bracing. MiTekrecommends that Stabilizers and requiredcross bracing beinstalled during truss erection,in accordancewithStabilizer Installation guide.REACTIONS.(lb/size)5=155/0-6-0(min. 0-1-8), 3=54/Mechanical, 4=26/Mechanical Max Horz5=91(LC 16) Max Uplift3=-73(LC 16), 4=-10(LC 16)MaxGrav5=178(LC 2), 3=79(LC 30), 4=49(LC 7) FORCES.(lb)-Max. Comp./Max.Ten.-All forces 250 (lb) orless exceptwhenshown. NOTES- 1)Wind:ASCE 7-10;Vult=115mph(3-second gust)Vasd=91mph;TCDL=6.0psf;BCDL=6.0psf; h=25ft; Cat. II;Exp C; enclosed;MWFRS(envelope) gable end zone and C-CExterior(2)-0-10-12 to 2-1-4,Interior(1) 2-1-4 to 2-8-10zone;cantileverleft and right exposed ; end verticalleft and right exposed;C-C formembers and forces&MWFRS forreactionsshown; Lumber DOL=1.60 plate grip DOL=1.60 2)TCLL:ASCE 7-10;Pr=20.0 psf(roofliveload: Lumber DOL=1.15Plate DOL=1.15);Pg=20.0 psf(groundsnow);Pf=15.4 psf(flat roofsnow: Lumber DOL=1.15Plate DOL=1.15); CategoryII;Exp C; PartiallyExp.; Ct=1.1 3) Unbalancedsnowloads have been considered for this design. 4)This truss has been designed for greater of minroofliveload of 12.0 psf or 2.00 times flatroofload of 15.4 psf on overhangs non-concurrentwith otherliveloads. 5)This truss has been designed for a 10.0 psf bottomchordliveload nonconcurrentwith any otherliveloads. 6) Refer to girder(s) for truss to trussconnections. 7)Providemechanicalconnection(by others) of truss to bearing platecapable of withstanding 100 lb uplift at joint(s) 3, 4. 8)This trussis designedin accordancewith the 2012 InternationalBuilding Code section 2306.1 and referencedstandardANSI/TPI 1. LOADCASE(S)Standard DE Job # 59223-W1 Dansco Engineering, LLC Date: 6/13/18 WARNING – VERIFY DESIGN PARAMETERS AND READ NOTES BEFORE FABRICATION AND INSTALLATION!!! This truss design is adequate for the design parameters shown. Review and approval of design parameters is the responsibility of the building designer, not the truss designer or truss engineer. Permanent bracing requirements against out-of-plane buckling are noted/shown for individual truss members (and for the truss as a whole) subjected to gravity and wind loads. Additional permanent bracing design shall be the responsibility of the design professional of record. Temporary and erection bracing shall be the responsibility of the contractor. Reference ANSI/TPI-1, “National Design Standard for Metal Plate Connected Wood Truss Construction” and TPI/WTCA BCSI-06, “Building Component Safety Information Guide to Good Practice for Handling, Installing, Restraining and Bracing of Metal Plate Connected Wood Trusses” for additional information. Job 1802242-12T Truss J15 TrussType Jack-Open Qty 22 Ply 1 1802242-12TDWHWoodside-West Clay- 4 Job Reference (optional)Run:8.200 s Apr72018 Print:8.200 s Apr72018MiTekIndustries,Inc.Tue Jun1221:11:282018 Page1ID:bRTO9oDnRLEHvJjVgeMKW3yF_s1-cY551txy4yw48XyNR?nIPb7HF9wDjxstBwB5Lmz6wGz Scale=1:25.2 W1 T1 B1 1 2 5 6 7 3 4 3x4 2x4 4-2-4 4-2-4 -0-10-12 0-10-12 4-2-4 4-2-4 1 -3 -4 4 -4 -15 3 -11 -7 4 -4 -15 9.0012 LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 10.0 SPACING- PlateGrip DOL Lumber DOL RepStressIncr Code 2-0-0 1.15 1.15 YES IBC2012/TPI2007 CSI. TC BC WB Matrix-MR 0.35 0.23 0.00 DEFL. Vert(LL) Vert(TL) Horz(TL) in 0.03 -0.04 0.05 (loc) 4-5 4-5 3 l/defl >999 >999 n/a L/d 240 180 n/a PLATES MT20 Weight: 13 lb FT= 20% GRIP 197/144 LUMBER- TOP CHORD2x4SPF No.2 BOT CHORD2x4SPF No.2WEBS2x4SPFStud BRACING- TOP CHORD Structuralwoodsheathing directly applied or 4-2-4 oc purlins, except end verticals.BOT CHORD Rigidceiling directly applied or 10-0-0 oc bracing. MiTekrecommends that Stabilizers and requiredcross bracing beinstalled during truss erection,in accordancewithStabilizer Installation guide.REACTIONS.(lb/size)5=201/0-6-0(min. 0-1-8), 3=90/Mechanical, 4=44/Mechanical Max Horz5=134(LC 16) Max Uplift3=-105(LC 16), 4=-6(LC 16)MaxGrav5=230(LC 2), 3=125(LC 30), 4=76(LC 7) FORCES.(lb)-Max. Comp./Max.Ten.-All forces 250 (lb) orless exceptwhenshown. NOTES- 1)Wind:ASCE 7-10;Vult=115mph(3-second gust)Vasd=91mph;TCDL=6.0psf;BCDL=6.0psf; h=25ft; Cat. II;Exp C; enclosed;MWFRS(envelope) gable end zone and C-CExterior(2)-0-10-12 to 2-1-4,Interior(1) 2-1-4 to 4-1-8zone;cantileverleft and right exposed ; end verticalleft and right exposed;C-C formembers and forces&MWFRS forreactionsshown; Lumber DOL=1.60 plate grip DOL=1.60 2)TCLL:ASCE 7-10;Pr=20.0 psf(roofliveload: Lumber DOL=1.15Plate DOL=1.15);Pg=20.0 psf(groundsnow);Pf=15.4 psf(flat roofsnow: Lumber DOL=1.15Plate DOL=1.15); CategoryII;Exp C; PartiallyExp.; Ct=1.1 3) Unbalancedsnowloads have been considered for this design. 4)This truss has been designed for greater of minroofliveload of 12.0 psf or 2.00 times flatroofload of 15.4 psf on overhangs non-concurrentwith otherliveloads. 5)This truss has been designed for a 10.0 psf bottomchordliveload nonconcurrentwith any otherliveloads. 6) Refer to girder(s) for truss to trussconnections. 7)Providemechanicalconnection(by others) of truss to bearing platecapable of withstanding 100 lb uplift at joint(s) 4 except(jt=lb) 3=105. 8)This trussis designedin accordancewith the 2012 InternationalBuilding Code section 2306.1 and referencedstandardANSI/TPI 1. LOADCASE(S)Standard DE Job # 59223-W1 Dansco Engineering, LLC Date: 6/13/18 WARNING – VERIFY DESIGN PARAMETERS AND READ NOTES BEFORE FABRICATION AND INSTALLATION!!! This truss design is adequate for the design parameters shown. Review and approval of design parameters is the responsibility of the building designer, not the truss designer or truss engineer. Permanent bracing requirements against out-of-plane buckling are noted/shown for individual truss members (and for the truss as a whole) subjected to gravity and wind loads. Additional permanent bracing design shall be the responsibility of the design professional of record. Temporary and erection bracing shall be the responsibility of the contractor. Reference ANSI/TPI-1, “National Design Standard for Metal Plate Connected Wood Truss Construction” and TPI/WTCA BCSI-06, “Building Component Safety Information Guide to Good Practice for Handling, Installing, Restraining and Bracing of Metal Plate Connected Wood Trusses” for additional information. Job 1802242-12T Truss J16 TrussType Jack-Open Qty 1 Ply 1 1802242-12TDWHWoodside-West Clay- 4 Job Reference (optional)Run:8.200 s Apr72018 Print:8.200 s Apr72018MiTekIndustries,Inc.Tue Jun1221:11:282018 Page1ID:bRTO9oDnRLEHvJjVgeMKW3yF_s1-cY551txy4yw48XyNR?nIPb7JP9xqjxstBwB5Lmz6wGz Scale=1:19.9 W1 T1 B1 1 2 5 6 3 4 3x4 2x4 2-9-6 2-9-6 -0-10-12 0-10-12 2-9-6 2-9-6 1 -3 -4 3 -4 -4 9.0012 LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 10.0 SPACING- PlateGrip DOL Lumber DOL RepStressIncr Code 2-0-0 1.15 1.15 YES IBC2012/TPI2007 CSI. TC BC WB Matrix-MR 0.21 0.13 0.00 DEFL. Vert(LL) Vert(TL) Horz(TL) in 0.01 -0.01 -0.02 (loc) 4-5 4-5 3 l/defl >999 >999 n/a L/d 240 180 n/a PLATES MT20 Weight: 10 lb FT= 20% GRIP 197/144 LUMBER- TOP CHORD2x4SPF No.2 BOT CHORD2x4SPF No.2WEBS2x4SPFStud BRACING- TOP CHORD Structuralwoodsheathing directly applied or 2-9-6 oc purlins, except end verticals.BOT CHORD Rigidceiling directly applied or 10-0-0 oc bracing. MiTekrecommends that Stabilizers and requiredcross bracing beinstalled during truss erection,in accordancewithStabilizer Installation guide.REACTIONS.(lb/size)5=155/0-6-0(min. 0-1-8), 3=54/Mechanical, 4=26/Mechanical Max Horz5=91(LC 16) Max Uplift3=-73(LC 16), 4=-10(LC 16)MaxGrav5=178(LC 2), 3=79(LC 30), 4=49(LC 7) FORCES.(lb)-Max. Comp./Max.Ten.-All forces 250 (lb) orless exceptwhenshown. NOTES- 1)Wind:ASCE 7-10;Vult=115mph(3-second gust)Vasd=91mph;TCDL=6.0psf;BCDL=6.0psf; h=25ft; Cat. II;Exp C; enclosed;MWFRS(envelope) gable end zone and C-CExterior(2)-0-10-12 to 2-1-4,Interior(1) 2-1-4 to 2-8-10zone;cantileverleft and right exposed ; end verticalleft and right exposed;C-C formembers and forces&MWFRS forreactionsshown; Lumber DOL=1.60 plate grip DOL=1.60 2)TCLL:ASCE 7-10;Pr=20.0 psf(roofliveload: Lumber DOL=1.15Plate DOL=1.15);Pg=20.0 psf(groundsnow);Pf=15.4 psf(flat roofsnow: Lumber DOL=1.15Plate DOL=1.15); CategoryII;Exp C; PartiallyExp.; Ct=1.1 3) Unbalancedsnowloads have been considered for this design. 4)This truss has been designed for greater of minroofliveload of 12.0 psf or 2.00 times flatroofload of 15.4 psf on overhangs non-concurrentwith otherliveloads. 5)This truss has been designed for a 10.0 psf bottomchordliveload nonconcurrentwith any otherliveloads. 6) Refer to girder(s) for truss to trussconnections. 7)Providemechanicalconnection(by others) of truss to bearing platecapable of withstanding 100 lb uplift at joint(s) 3, 4. 8)This trussis designedin accordancewith the 2012 InternationalBuilding Code section 2306.1 and referencedstandardANSI/TPI 1. LOADCASE(S)Standard DE Job # 59223-W1 Dansco Engineering, LLC Date: 6/13/18 WARNING – VERIFY DESIGN PARAMETERS AND READ NOTES BEFORE FABRICATION AND INSTALLATION!!! This truss design is adequate for the design parameters shown. Review and approval of design parameters is the responsibility of the building designer, not the truss designer or truss engineer. Permanent bracing requirements against out-of-plane buckling are noted/shown for individual truss members (and for the truss as a whole) subjected to gravity and wind loads. Additional permanent bracing design shall be the responsibility of the design professional of record. Temporary and erection bracing shall be the responsibility of the contractor. Reference ANSI/TPI-1, “National Design Standard for Metal Plate Connected Wood Truss Construction” and TPI/WTCA BCSI-06, “Building Component Safety Information Guide to Good Practice for Handling, Installing, Restraining and Bracing of Metal Plate Connected Wood Trusses” for additional information. Job 1802242-12T Truss J17 TrussType Jack-Open Qty 1 Ply 1 1802242-12TDWHWoodside-West Clay- 4 Job Reference (optional)Run:8.200 s Apr72018 Print:8.200 s Apr72018MiTekIndustries,Inc.Tue Jun1221:11:292018 Page1ID:bRTO9oDnRLEHvJjVgeMKW3yF_s1-4leTEDyarF2xlhXa_jIXxogVRZI2SO61QaxetCz6wGy Scale=1:14.9 W1 T1 B1 1 2 5 3 4 2x4 2x4 1-5-6 1-5-6 -0-10-12 0-10-12 1-5-6 1-5-6 1 -3 -4 2 -4 -4 1 -10 -12 2 -4 -4 9.0012 LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 10.0 SPACING- PlateGrip DOL Lumber DOL RepStressIncr Code 2-0-0 1.15 1.15 YES IBC2012/TPI2007 CSI. TC BC WB Matrix-MR 0.13 0.07 0.00 DEFL. Vert(LL) Vert(TL) Horz(TL) in -0.00 -0.00 -0.01 (loc) 5 5 3 l/defl >999 >999 n/a L/d 240 180 n/a PLATES MT20 Weight: 6 lb FT= 20% GRIP 197/144 LUMBER- TOP CHORD2x4SPF No.2 BOT CHORD2x4SPF No.2WEBS2x4SPFStud BRACING- TOP CHORD Structuralwoodsheathing directly applied or 1-5-6 oc purlins, except end verticals.BOT CHORD Rigidceiling directly applied or 10-0-0 oc bracing. MiTekrecommends that Stabilizers and requiredcross bracing beinstalled during truss erection,in accordancewithStabilizer Installation guide.REACTIONS.(lb/size)5=120/0-6-0(min. 0-1-8), 3=15/Mechanical, 4=9/Mechanical Max Horz5=59(LC 13) Max Uplift3=-41(LC 16), 4=-15(LC 16)MaxGrav5=145(LC 22), 3=32(LC 30), 4=27(LC 14) FORCES.(lb)-Max. Comp./Max.Ten.-All forces 250 (lb) orless exceptwhenshown. NOTES- 1)Wind:ASCE 7-10;Vult=115mph(3-second gust)Vasd=91mph;TCDL=6.0psf;BCDL=6.0psf; h=25ft; Cat. II;Exp C; enclosed;MWFRS(envelope) gable end zone and C-CExterior(2)zone;cantileverleft and right exposed ; end verticalleft and right exposed;C-C formembers and forces&MWFRS forreactionsshown; Lumber DOL=1.60 plate grip DOL=1.60 2)TCLL:ASCE 7-10;Pr=20.0 psf(roofliveload: Lumber DOL=1.15Plate DOL=1.15);Pg=20.0 psf(groundsnow);Pf=15.4 psf(flat roofsnow: Lumber DOL=1.15Plate DOL=1.15); CategoryII;Exp C; PartiallyExp.; Ct=1.1 3) Unbalancedsnowloads have been considered for this design. 4)This truss has been designed for greater of minroofliveload of 12.0 psf or 2.00 times flatroofload of 15.4 psf on overhangs non-concurrentwith otherliveloads. 5)This truss has been designed for a 10.0 psf bottomchordliveload nonconcurrentwith any otherliveloads. 6) Refer to girder(s) for truss to trussconnections. 7)Providemechanicalconnection(by others) of truss to bearing platecapable of withstanding 100 lb uplift at joint(s) 3, 4. 8)This trussis designedin accordancewith the 2012 InternationalBuilding Code section 2306.1 and referencedstandardANSI/TPI 1. LOADCASE(S)Standard DE Job # 59223-W1 Dansco Engineering, LLC Date: 6/13/18 WARNING – VERIFY DESIGN PARAMETERS AND READ NOTES BEFORE FABRICATION AND INSTALLATION!!! This truss design is adequate for the design parameters shown. Review and approval of design parameters is the responsibility of the building designer, not the truss designer or truss engineer. Permanent bracing requirements against out-of-plane buckling are noted/shown for individual truss members (and for the truss as a whole) subjected to gravity and wind loads. Additional permanent bracing design shall be the responsibility of the design professional of record. Temporary and erection bracing shall be the responsibility of the contractor. Reference ANSI/TPI-1, “National Design Standard for Metal Plate Connected Wood Truss Construction” and TPI/WTCA BCSI-06, “Building Component Safety Information Guide to Good Practice for Handling, Installing, Restraining and Bracing of Metal Plate Connected Wood Trusses” for additional information. Job 1802242-12T Truss J18 TrussType Jack-OpenGirder Qty 1 Ply 1 1802242-12TDWHWoodside-West Clay- 4 Job Reference (optional)Run:8.200 s Apr72018 Print:8.200 s Apr72018MiTekIndustries,Inc.Tue Jun1221:11:302018 Page1ID:bRTO9oDnRLEHvJjVgeMKW3yF_s1-YxCrSZyCcZAoNq6mYQpmU0DV2zXoBrMAeEgBPfz6wGx Scale=1:25.7 W1 T1 B1 1 2 5 6 7 3 8 9 4 4x4 3x4 3-8-3 3-8-3 7-4-5 3-8-3 -1-3-3 1-3-3 3-8-3 3-8-3 7-4-5 3-8-3 1 -3 -4 4 -4 -0 3 -11 -9 4 -4 -0 4.9912 LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 10.0 SPACING- PlateGrip DOL Lumber DOL RepStressIncr Code 2-0-0 1.15 1.15 NO IBC2012/TPI2007 CSI. TC BC WB Matrix-MR 0.85 0.55 0.00 DEFL. Vert(LL) Vert(TL) Horz(TL) in 0.18 -0.34 0.14 (loc) 4-5 4-5 3 l/defl >465 >256 n/a L/d 240 180 n/a PLATES MT20 Weight: 20 lb FT= 20% GRIP 197/144 LUMBER- TOP CHORD2x4SPF No.2 BOT CHORD2x4SPF No.2WEBS2x4SPFStud BRACING- TOP CHORD Structuralwoodsheathing directly applied or 6-0-0 oc purlins, except end verticals.BOT CHORD Rigidceiling directly applied or 10-0-0 oc bracing. MiTekrecommends that Stabilizers and requiredcross bracing beinstalled during truss erection,in accordancewithStabilizer Installation guide.REACTIONS.(lb/size)5=239/0-9-11(min. 0-1-8), 3=210/Mechanical, 4=97/Mechanical Max Horz5=119(LC 12) Max Uplift5=-103(LC 16), 3=-184(LC 12)MaxGrav5=273(LC 2), 3=247(LC 2), 4=152(LC 7) FORCES.(lb)-Max. Comp./Max.Ten.-All forces 250 (lb) orless exceptwhenshown. NOTES- 1)Wind:ASCE 7-10;Vult=115mph(3-second gust)Vasd=91mph;TCDL=6.0psf;BCDL=6.0psf; h=25ft; Cat. II;Exp C; enclosed;MWFRS(envelope) gable end zone;cantileverleft and right exposed ; end verticalleft and right exposed; Lumber DOL=1.60 plate grip DOL=1.60 2)TCLL:ASCE 7-10;Pr=20.0 psf(roofliveload: Lumber DOL=1.15Plate DOL=1.15);Pg=20.0 psf(groundsnow);Pf=15.4 psf(flat roofsnow: Lumber DOL=1.15Plate DOL=1.15); CategoryII;Exp C; PartiallyExp.; Ct=1.1 3) Unbalancedsnowloads have been considered for this design. 4)This truss has been designed for greater of minroofliveload of 12.0 psf or 2.00 times flatroofload of 15.4 psf on overhangs non-concurrentwith otherliveloads. 5)This truss has been designed for a 10.0 psf bottomchordliveload nonconcurrentwith any otherliveloads. 6) Refer to girder(s) for truss to trussconnections. 7)Providemechanicalconnection(by others) of truss to bearing platecapable of withstanding 100 lb uplift at joint(s) except(jt=lb) 5=103, 3=184. 8)This trussis designedin accordancewith the 2012 InternationalBuilding Code section 2306.1 and referencedstandardANSI/TPI 1. 9) Hanger(s) or otherconnection device(s)shall be providedsufficient to supportconcentratedload(s) 75 lb down and 31 lb up at 2-8-3, and 93 lb down and 73 lb up at 5-1-0 on top chord, and 16 lb down and 22 lb up at 2-8-3, and 23 lb down and 24 lb up at 5-1-0 on bottomchord.The design/selection of suchconnection device(s)is the responsibility of others. 10)In the LOAD CASE(S)section,loads applied to the face of the truss are noted as front(F) or back(B). LOADCASE(S)Standard 1) Dead +Snow(balanced): LumberIncrease=1.15,PlateIncrease=1.15Uniform Loads(plf) Vert: 1-2=-51 Concentrated Loads(lb)Vert: 8=0(F) 9=-2(F) Trapezoidal Loads(plf) Vert: 2=-2(F=24,B=24)-to-3=-93(F=-21,B=-21), 5=0(F=10,B=10)-to-4=-37(F=-8,B=-8) DE Job # 59223-W1 Dansco Engineering, LLC Date: 6/13/18 WARNING – VERIFY DESIGN PARAMETERS AND READ NOTES BEFORE FABRICATION AND INSTALLATION!!! This truss design is adequate for the design parameters shown. Review and approval of design parameters is the responsibility of the building designer, not the truss designer or truss engineer. Permanent bracing requirements against out-of-plane buckling are noted/shown for individual truss members (and for the truss as a whole) subjected to gravity and wind loads. Additional permanent bracing design shall be the responsibility of the design professional of record. Temporary and erection bracing shall be the responsibility of the contractor. Reference ANSI/TPI-1, “National Design Standard for Metal Plate Connected Wood Truss Construction” and TPI/WTCA BCSI-06, “Building Component Safety Information Guide to Good Practice for Handling, Installing, Restraining and Bracing of Metal Plate Connected Wood Trusses” for additional information. Job 1802242-12T Truss J19 TrussType Jack-OpenGirder Qty 1 Ply 1 1802242-12TDWHWoodside-West Clay- 4 Job Reference (optional)Run:8.200 s Apr72018 Print:8.200 s Apr72018MiTekIndustries,Inc.Tue Jun1221:11:312018 Page1ID:bRTO9oDnRLEHvJjVgeMKW3yF_s1-07mDfvzrNtIf?_gy67K?0DlpYMyEwIbJtuQlx5z6wGw Scale=1:17.6 W1 T1 B1 1 4 5 6 2 7 3 3x4 1.5x4 5-2-8 5-2-8 5-2-8 5-2-8 1 -1 -1 2 -9 -2 2 -4 -15 2 -9 -2 3.8412 LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 10.0 SPACING- PlateGrip DOL Lumber DOL RepStressIncr Code 2-0-0 1.15 1.15 NO IBC2012/TPI2007 CSI. TC BC WB Matrix-MR 0.28 0.21 0.00 DEFL. Vert(LL) Vert(TL) Horz(TL) in -0.03 -0.07 -0.03 (loc) 3-4 3-4 2 l/defl >999 >906 n/a L/d 240 180 n/a PLATES MT20 Weight: 13 lb FT= 20% GRIP 197/144 LUMBER- TOP CHORD2x4SPF No.2 BOT CHORD2x4SPF No.2WEBS2x4SPFStud BRACING- TOP CHORD Structuralwoodsheathing directly applied or 5-2-8 oc purlins, except end verticals.BOT CHORD Rigidceiling directly applied or 10-0-0 oc bracing. MiTekrecommends that Stabilizers and requiredcross bracing beinstalled during truss erection,in accordancewithStabilizer Installation guide.REACTIONS.(lb/size)4=78/0-5-9(min. 0-1-8), 2=106/Mechanical, 3=49/Mechanical Max Horz4=53(LC 11) Max Uplift4=-66(LC 10), 2=-66(LC 12)MaxGrav4=94(LC 7), 2=124(LC 2), 3=89(LC 7) FORCES.(lb)-Max. Comp./Max.Ten.-All forces 250 (lb) orless exceptwhenshown. NOTES- 1)Wind:ASCE 7-10;Vult=115mph(3-second gust)Vasd=91mph;TCDL=6.0psf;BCDL=6.0psf; h=25ft; Cat. II;Exp C; enclosed;MWFRS(envelope) gable end zone;cantileverleft and right exposed ; end verticalleft and right exposed; Lumber DOL=1.60 plate grip DOL=1.60 2)TCLL:ASCE 7-10;Pr=20.0 psf(roofliveload: Lumber DOL=1.15Plate DOL=1.15);Pg=20.0 psf(groundsnow);Pf=15.4 psf(flat roofsnow: Lumber DOL=1.15Plate DOL=1.15); CategoryII;Exp C; PartiallyExp.; Ct=1.1 3) Unbalancedsnowloads have been considered for this design. 4)This truss has been designed for a 10.0 psf bottomchordliveload nonconcurrentwith any otherliveloads. 5) Refer to girder(s) for truss to trussconnections. 6)Providemechanicalconnection(by others) of truss to bearing platecapable of withstanding 100 lb uplift at joint(s) 4, 2. 7)This trussis designedin accordancewith the 2012 InternationalBuilding Code section 2306.1 and referencedstandardANSI/TPI 1. 8) Hanger(s) or otherconnection device(s)shall be providedsufficient to supportconcentratedload(s) 17 lb down and 33 lb up at 3-0-2 on top chord, and 5 lb down at 3-0-2 on bottomchord.The design/selection of suchconnection device(s)is the responsibility of others. 9)In the LOAD CASE(S)section,loads applied to the face of the truss are noted as front(F) or back(B). LOADCASE(S)Standard 1) Dead +Snow(balanced): LumberIncrease=1.15,PlateIncrease=1.15Concentrated Loads(lb) Vert: 7=-2(B) Trapezoidal Loads(plf)Vert: 1=0(F=25,B=25)-to-2=-66(F=-8,B=-8), 4=0(F=10,B=10)-to-3=-26(F=-3,B=-3) DE Job # 59223-W1 Dansco Engineering, LLC Date: 6/13/18 WARNING – VERIFY DESIGN PARAMETERS AND READ NOTES BEFORE FABRICATION AND INSTALLATION!!! This truss design is adequate for the design parameters shown. Review and approval of design parameters is the responsibility of the building designer, not the truss designer or truss engineer. Permanent bracing requirements against out-of-plane buckling are noted/shown for individual truss members (and for the truss as a whole) subjected to gravity and wind loads. Additional permanent bracing design shall be the responsibility of the design professional of record. Temporary and erection bracing shall be the responsibility of the contractor. Reference ANSI/TPI-1, “National Design Standard for Metal Plate Connected Wood Truss Construction” and TPI/WTCA BCSI-06, “Building Component Safety Information Guide to Good Practice for Handling, Installing, Restraining and Bracing of Metal Plate Connected Wood Trusses” for additional information. Job 1802242-12T Truss J20 TrussType Jack-Open Qty 1 Ply 1 1802242-12TDWHWoodside-West Clay- 4 Job Reference (optional)Run:8.200 s Apr72018 Print:8.200 s Apr72018MiTekIndustries,Inc.Tue Jun1221:11:322018 Page1ID:bRTO9oDnRLEHvJjVgeMKW3yF_s1-UJKbsF_T8ARWc8F9grsEZRI1DmKzflrT6Y9IUXz6wGv Scale=1:13.1 W1 T1 B1 1 4 2 3 1.5x4 1.5x4 1-10-8 1-10-8 1-10-8 1-10-8 1 -1 -0 2 -0 -4 1 -7 -10 2 -0 -4 6.0012 LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 10.0 SPACING- PlateGrip DOL Lumber DOL RepStressIncr Code 2-0-0 1.15 1.15 YES IBC2012/TPI2007 CSI. TC BC WB Matrix-MR 0.10 0.05 0.00 DEFL. Vert(LL) Vert(TL) Horz(TL) in -0.00 -0.00 -0.00 (loc) 4 3-4 2 l/defl >999 >999 n/a L/d 240 180 n/a PLATES MT20 Weight: 5 lb FT= 20% GRIP 197/144 LUMBER- TOP CHORD2x4SPF No.2 BOT CHORD2x4SPF No.2WEBS2x4SPFStud BRACING- TOP CHORD Structuralwoodsheathing directly applied or 1-10-8 oc purlins, except end verticals.BOT CHORD Rigidceiling directly applied or 10-0-0 oc bracing. MiTekrecommends that Stabilizers and requiredcross bracing beinstalled during truss erection,in accordancewithStabilizer Installation guide.REACTIONS.(lb/size)4=61/Mechanical, 2=42/Mechanical, 3=19/Mechanical Max Horz4=40(LC 13) Max Uplift2=-38(LC 16)MaxGrav4=69(LC 2), 2=49(LC 2), 3=33(LC 7) FORCES.(lb)-Max. Comp./Max.Ten.-All forces 250 (lb) orless exceptwhenshown. NOTES- 1)Wind:ASCE 7-10;Vult=115mph(3-second gust)Vasd=91mph;TCDL=6.0psf;BCDL=6.0psf; h=25ft; Cat. II;Exp C; enclosed;MWFRS(envelope) gable end zone and C-CExterior(2)zone;cantileverleft and right exposed ; end verticalleft and right exposed;C-C formembers and forces&MWFRS forreactionsshown; Lumber DOL=1.60 plate grip DOL=1.60 2)TCLL:ASCE 7-10;Pr=20.0 psf(roofliveload: Lumber DOL=1.15Plate DOL=1.15);Pg=20.0 psf(groundsnow);Pf=15.4 psf(flat roofsnow: Lumber DOL=1.15Plate DOL=1.15); CategoryII;Exp C; PartiallyExp.; Ct=1.1 3) Unbalancedsnowloads have been considered for this design. 4)This truss has been designed for a 10.0 psf bottomchordliveload nonconcurrentwith any otherliveloads. 5) Refer to girder(s) for truss to trussconnections. 6)Providemechanicalconnection(by others) of truss to bearing platecapable of withstanding 100 lb uplift at joint(s) 2. 7)This trussis designedin accordancewith the 2012 InternationalBuilding Code section 2306.1 and referencedstandardANSI/TPI 1. LOADCASE(S)Standard DE Job # 59223-W1 Dansco Engineering, LLC Date: 6/13/18 WARNING – VERIFY DESIGN PARAMETERS AND READ NOTES BEFORE FABRICATION AND INSTALLATION!!! This truss design is adequate for the design parameters shown. Review and approval of design parameters is the responsibility of the building designer, not the truss designer or truss engineer. Permanent bracing requirements against out-of-plane buckling are noted/shown for individual truss members (and for the truss as a whole) subjected to gravity and wind loads. Additional permanent bracing design shall be the responsibility of the design professional of record. Temporary and erection bracing shall be the responsibility of the contractor. Reference ANSI/TPI-1, “National Design Standard for Metal Plate Connected Wood Truss Construction” and TPI/WTCA BCSI-06, “Building Component Safety Information Guide to Good Practice for Handling, Installing, Restraining and Bracing of Metal Plate Connected Wood Trusses” for additional information. Job 1802242-12T Truss J21 TrussType Jack-Open Qty 1 Ply 1 1802242-12TDWHWoodside-West Clay- 4 Job Reference (optional)Run:8.200 s Apr72018 Print:8.200 s Apr72018MiTekIndustries,Inc.Tue Jun1221:11:332018 Page1ID:bRTO9oDnRLEHvJjVgeMKW3yF_s1-zWu_4a?5vUZNEIqLDYNT6erB3Ag3OB5cLCvr0zz6wGu Scale=1:13.2 W1 T1 B1 1 2 5 6 3 4 1.5x4 2x4 2-4-15 2-4-15 -1-2-12 1-2-12 2-4-15 2-4-15 1 -0 -9 2 -0 -10 5.0012 LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 10.0 SPACING- PlateGrip DOL Lumber DOL RepStressIncr Code 2-0-0 1.15 1.15 YES IBC2012/TPI2007 CSI. TC BC WB Matrix-MR 0.16 0.06 0.00 DEFL. Vert(LL) Vert(TL) Horz(TL) in 0.00 -0.00 -0.01 (loc) 4-5 4-5 3 l/defl >999 >999 n/a L/d 240 180 n/a PLATES MT20 Weight: 8 lb FT= 20% GRIP 197/144 LUMBER- TOP CHORD2x4SPF No.2 BOT CHORD2x4SPF No.2WEBS2x4SPFStud BRACING- TOP CHORD Structuralwoodsheathing directly applied or 2-4-15 oc purlins, except end verticals.BOT CHORD Rigidceiling directly applied or 10-0-0 oc bracing. MiTekrecommends that Stabilizers and requiredcross bracing beinstalled during truss erection,in accordancewithStabilizer Installation guide.REACTIONS.(lb/size)5=170/0-4-0(min. 0-1-8), 3=38/Mechanical, 4=18/Mechanical Max Horz5=54(LC 13) Max Uplift5=-64(LC 12), 3=-36(LC 16), 4=-16(LC 13)MaxGrav5=196(LC 2), 3=45(LC 2), 4=40(LC 7) FORCES.(lb)-Max. Comp./Max.Ten.-All forces 250 (lb) orless exceptwhenshown. NOTES- 1)Wind:ASCE 7-10;Vult=115mph(3-second gust)Vasd=91mph;TCDL=6.0psf;BCDL=6.0psf; h=25ft; Cat. II;Exp C; enclosed;MWFRS(envelope) gable end zone and C-CExterior(2)-1-2-12 to 1-9-4,Interior(1) 1-9-4 to 2-4-3zone;cantileverleft exposed ; endverticalleft exposed; porchleft and right exposed;C-C formembers and forces&MWFRS forreactionsshown; Lumber DOL=1.60 plate grip DOL=1.60 2)TCLL:ASCE 7-10;Pr=20.0 psf(roofliveload: Lumber DOL=1.15Plate DOL=1.15);Pg=20.0 psf(groundsnow);Pf=15.4 psf(flat roofsnow: Lumber DOL=1.15Plate DOL=1.15); CategoryII;Exp C; PartiallyExp.; Ct=1.1 3) Unbalancedsnowloads have been considered for this design. 4)This truss has been designed for greater of minroofliveload of 12.0 psf or 2.00 times flatroofload of 15.4 psf on overhangs non-concurrentwith otherliveloads. 5)This truss has been designed for a 10.0 psf bottomchordliveload nonconcurrentwith any otherliveloads. 6) Refer to girder(s) for truss to trussconnections. 7)Providemechanicalconnection(by others) of truss to bearing platecapable of withstanding 100 lb uplift at joint(s) 5, 3, 4. 8)This trussis designedin accordancewith the 2012 InternationalBuilding Code section 2306.1 and referencedstandardANSI/TPI 1. LOADCASE(S)Standard DE Job # 59223-W1 Dansco Engineering, LLC Date: 6/13/18 WARNING – VERIFY DESIGN PARAMETERS AND READ NOTES BEFORE FABRICATION AND INSTALLATION!!! This truss design is adequate for the design parameters shown. Review and approval of design parameters is the responsibility of the building designer, not the truss designer or truss engineer. Permanent bracing requirements against out-of-plane buckling are noted/shown for individual truss members (and for the truss as a whole) subjected to gravity and wind loads. Additional permanent bracing design shall be the responsibility of the design professional of record. Temporary and erection bracing shall be the responsibility of the contractor. Reference ANSI/TPI-1, “National Design Standard for Metal Plate Connected Wood Truss Construction” and TPI/WTCA BCSI-06, “Building Component Safety Information Guide to Good Practice for Handling, Installing, Restraining and Bracing of Metal Plate Connected Wood Trusses” for additional information. Job 1802242-12T Truss J22 TrussType DiagonalHipGirder Qty 1 Ply 1 1802242-12TDWHWoodside-West Clay- 4 Job Reference (optional)Run:8.200 s Apr72018 Print:8.200 s Apr72018MiTekIndustries,Inc.Tue Jun1221:11:342018 Page1ID:bRTO9oDnRLEHvJjVgeMKW3yF_s1-RiSMHw0jgohEsSPXnGuiesNIpaye7eLmZsePYQz6wGt Scale=1:18.1 W1 T1 B1 1 2 5 6 3 7 4 3x4 3x4 6-0-1 6-0-1 -1-11-11 1-11-11 3-0-0 3-0-0 6-0-1 3-0-0 1 -1 -6 2 -10 -10 0 -4 -1 2 -6 -9 2 -10 -10 3.5412 LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 10.0 SPACING- PlateGrip DOL Lumber DOL RepStressIncr Code 2-0-0 1.15 1.15 NO IBC2012/TPI2007 CSI. TC BC WB Matrix-MR 0.41 0.30 0.00 DEFL. Vert(LL) Vert(TL) Horz(TL) in 0.08 -0.12 -0.05 (loc) 4-5 4-5 3 l/defl >882 >595 n/a L/d 240 180 n/a PLATES MT20 Weight: 17 lb FT= 20% GRIP 197/144 LUMBER- TOP CHORD2x4SPF No.2 BOT CHORD2x4SPF No.2WEBS2x4SPFStud BRACING- TOP CHORD Structuralwoodsheathing directly applied or 6-0-0 oc purlins, except end verticals.BOT CHORD Rigidceiling directly applied or 10-0-0 oc bracing. MiTekrecommends that Stabilizers and requiredcross bracing beinstalled during truss erection,in accordancewithStabilizer Installation guide.REACTIONS.(lb/size)5=233/0-4-15(min. 0-1-8), 3=131/Mechanical, 4=56/Mechanical Max Horz5=72(LC 8) Max Uplift5=-133(LC 8), 3=-89(LC 12), 4=-1(LC 12)MaxGrav5=269(LC 2), 3=153(LC 2), 4=108(LC 7) FORCES.(lb)-Max. Comp./Max.Ten.-All forces 250 (lb) orless exceptwhenshown. NOTES- 1)Wind:ASCE 7-10;Vult=115mph(3-second gust)Vasd=91mph;TCDL=6.0psf;BCDL=6.0psf; h=25ft; Cat. II;Exp C; enclosed;MWFRS(envelope) gable end zone;cantileverleft and right exposed ; end verticalleft and right exposed; Lumber DOL=1.60 plate grip DOL=1.60 2)TCLL:ASCE 7-10;Pr=20.0 psf(roofliveload: Lumber DOL=1.15Plate DOL=1.15);Pg=20.0 psf(groundsnow);Pf=15.4 psf(flat roofsnow: Lumber DOL=1.15Plate DOL=1.15); CategoryII;Exp C; PartiallyExp.; Ct=1.1 3) Unbalancedsnowloads have been considered for this design. 4)This truss has been designed for greater of minroofliveload of 12.0 psf or 2.00 times flatroofload of 15.4 psf on overhangs non-concurrentwith otherliveloads. 5)This truss has been designed for a 10.0 psf bottomchordliveload nonconcurrentwith any otherliveloads. 6) Refer to girder(s) for truss to trussconnections. 7)Providemechanicalconnection(by others) of truss to bearing platecapable of withstanding 100 lb uplift at joint(s) 3, 4 except(jt=lb) 5=133. 8)This trussis designedin accordancewith the 2012 InternationalBuilding Code section 2306.1 and referencedstandardANSI/TPI 1. 9) Hanger(s) or otherconnection device(s)shall be providedsufficient to supportconcentratedload(s) 16 lb down and 23 lb up at 3-3-2, and 17 lb down and 30 lb up at 3-3-2 on top chord, and 27 lb up at 3-3-2, and 1 lb down and 28 lb up at 3-3-2 on bottom chord.The design/selection of suchconnection device(s)is the responsibility of others. 10)In the LOAD CASE(S)section,loads applied to the face of the truss are noted as front(F) or back(B). LOADCASE(S)Standard 1) Dead +Snow(balanced): LumberIncrease=1.15,PlateIncrease=1.15Uniform Loads(plf) Vert: 1-2=-51 Concentrated Loads(lb)Vert: 7=1(F=1,B=0) Trapezoidal Loads(plf) Vert: 2=-2(F=24,B=24)-to-3=-76(F=-13,B=-13), 5=0(F=10,B=10)-to-4=-30(F=-5,B=-5) DE Job # 59223-W1 Dansco Engineering, LLC Date: 6/13/18 WARNING – VERIFY DESIGN PARAMETERS AND READ NOTES BEFORE FABRICATION AND INSTALLATION!!! This truss design is adequate for the design parameters shown. Review and approval of design parameters is the responsibility of the building designer, not the truss designer or truss engineer. Permanent bracing requirements against out-of-plane buckling are noted/shown for individual truss members (and for the truss as a whole) subjected to gravity and wind loads. Additional permanent bracing design shall be the responsibility of the design professional of record. Temporary and erection bracing shall be the responsibility of the contractor. Reference ANSI/TPI-1, “National Design Standard for Metal Plate Connected Wood Truss Construction” and TPI/WTCA BCSI-06, “Building Component Safety Information Guide to Good Practice for Handling, Installing, Restraining and Bracing of Metal Plate Connected Wood Trusses” for additional information. Job 1802242-12T Truss J23 TrussType Jack-Open Qty 1 Ply 1 1802242-12TDWHWoodside-West Clay- 4 Job Reference (optional)Run:8.200 s Apr72018 Print:8.200 s Apr72018MiTekIndustries,Inc.Tue Jun1221:11:342018 Page1ID:bRTO9oDnRLEHvJjVgeMKW3yF_s1-RiSMHw0jgohEsSPXnGuiesNMKa0N7eLmZsePYQz6wGt Scale=1:13.2 W1 T1 B1 1 2 5 6 3 4 1.5x4 2x4 2-2-15 2-2-15 -1-4-12 1-4-12 2-2-15 2-2-15 1 -1 -6 2 -0 -10 5.0012 LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 10.0 SPACING- PlateGrip DOL Lumber DOL RepStressIncr Code 2-0-0 1.15 1.15 YES IBC2012/TPI2007 CSI. TC BC WB Matrix-MR 0.19 0.06 0.00 DEFL. Vert(LL) Vert(TL) Horz(TL) in 0.00 -0.00 -0.01 (loc) 4-5 4-5 3 l/defl >999 >999 n/a L/d 240 180 n/a PLATES MT20 Weight: 8 lb FT= 20% GRIP 197/144 LUMBER- TOP CHORD2x4SPF No.2 BOT CHORD2x4SPF No.2WEBS2x4SPFStud BRACING- TOP CHORD Structuralwoodsheathing directly applied or 2-2-15 oc purlins, except end verticals.BOT CHORD Rigidceiling directly applied or 10-0-0 oc bracing. MiTekrecommends that Stabilizers and requiredcross bracing beinstalled during truss erection,in accordancewithStabilizer Installation guide.REACTIONS.(lb/size)5=180/0-4-0(min. 0-1-8), 3=29/Mechanical, 4=14/Mechanical Max Horz5=55(LC 13) Max Uplift5=-71(LC 12), 3=-32(LC 16), 4=-17(LC 13)MaxGrav5=214(LC 22), 3=34(LC 2), 4=36(LC 7) FORCES.(lb)-Max. Comp./Max.Ten.-All forces 250 (lb) orless exceptwhenshown. NOTES- 1)Wind:ASCE 7-10;Vult=115mph(3-second gust)Vasd=91mph;TCDL=6.0psf;BCDL=6.0psf; h=25ft; Cat. II;Exp C; enclosed;MWFRS(envelope) gable end zone and C-CExterior(2)-1-4-12 to 1-7-4,Interior(1) 1-7-4 to 2-2-3zone;cantileverleft exposed ; endverticalleft exposed; porchleft and right exposed;C-C formembers and forces&MWFRS forreactionsshown; Lumber DOL=1.60 plate grip DOL=1.60 2)TCLL:ASCE 7-10;Pr=20.0 psf(roofliveload: Lumber DOL=1.15Plate DOL=1.15);Pg=20.0 psf(groundsnow);Pf=15.4 psf(flat roofsnow: Lumber DOL=1.15Plate DOL=1.15); CategoryII;Exp C; PartiallyExp.; Ct=1.1 3) Unbalancedsnowloads have been considered for this design. 4)This truss has been designed for greater of minroofliveload of 12.0 psf or 2.00 times flatroofload of 15.4 psf on overhangs non-concurrentwith otherliveloads. 5)This truss has been designed for a 10.0 psf bottomchordliveload nonconcurrentwith any otherliveloads. 6) Refer to girder(s) for truss to trussconnections. 7)Bearing at joint(s) 5 considers parallel to grainvalue usingANSI/TPI 1 angle to grain formula.Building designershouldverify capacity of bearingsurface. 8)Providemechanicalconnection(by others) of truss to bearing platecapable of withstanding 100 lb uplift at joint(s) 5, 3, 4.9)This trussis designedin accordancewith the 2012 InternationalBuilding Code section 2306.1 and referencedstandardANSI/TPI 1. LOADCASE(S)Standard DE Job # 59223-W1 Dansco Engineering, LLC Date: 6/13/18 WARNING – VERIFY DESIGN PARAMETERS AND READ NOTES BEFORE FABRICATION AND INSTALLATION!!! This truss design is adequate for the design parameters shown. Review and approval of design parameters is the responsibility of the building designer, not the truss designer or truss engineer. Permanent bracing requirements against out-of-plane buckling are noted/shown for individual truss members (and for the truss as a whole) subjected to gravity and wind loads. Additional permanent bracing design shall be the responsibility of the design professional of record. Temporary and erection bracing shall be the responsibility of the contractor. Reference ANSI/TPI-1, “National Design Standard for Metal Plate Connected Wood Truss Construction” and TPI/WTCA BCSI-06, “Building Component Safety Information Guide to Good Practice for Handling, Installing, Restraining and Bracing of Metal Plate Connected Wood Trusses” for additional information. Job 1802242-12T Truss J24 TrussType Jack-Open Qty 15 Ply 1 1802242-12TDWHWoodside-West Clay- 4 Job Reference (optional)Run:8.200 s Apr72018 Print:8.200 s Apr72018MiTekIndustries,Inc.Tue Jun1221:11:352018 Page1ID:bRTO9oDnRLEHvJjVgeMKW3yF_s1-vu0kVG0LR5p5Uc_kLzPxB3wWN_JHs5bvoVOy5sz6wGs Scale=1:17.5 W1 T1 B1 1 2 5 6 7 3 4 2x4 3x4 4-4-0 4-4-0 -1-4-12 1-4-12 4-4-0 4-4-0 1 -1 -6 2 -11 -1 2 -6 -10 2 -11 -1 5.0012 LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 10.0 SPACING- PlateGrip DOL Lumber DOL RepStressIncr Code 2-0-0 1.15 1.15 YES IBC2012/TPI2007 CSI. TC BC WB Matrix-MR 0.23 0.21 0.00 DEFL. Vert(LL) Vert(TL) Horz(TL) in 0.05 -0.04 -0.04 (loc) 4-5 4-5 3 l/defl >999 >999 n/a L/d 240 180 n/a PLATES MT20 Weight: 13 lb FT= 20% GRIP 197/144 LUMBER- TOP CHORD2x4SPF No.2 BOT CHORD2x4SPF No.2WEBS2x4SPFStud BRACING- TOP CHORD Structuralwoodsheathing directly applied or 4-4-0 oc purlins, except end verticals.BOT CHORD Rigidceiling directly applied or 10-0-0 oc bracing. MiTekrecommends that Stabilizers and requiredcross bracing beinstalled during truss erection,in accordancewithStabilizer Installation guide.REACTIONS.(lb/size)5=239/0-4-0(min. 0-1-8), 3=89/Mechanical, 4=42/Mechanical Max Horz5=80(LC 16) Max Uplift5=-84(LC 12), 3=-69(LC 16), 4=-24(LC 13)MaxGrav5=275(LC 2), 3=105(LC 2), 4=77(LC 7) FORCES.(lb)-Max. Comp./Max.Ten.-All forces 250 (lb) orless exceptwhenshown. NOTES- 1)Wind:ASCE 7-10;Vult=115mph(3-second gust)Vasd=91mph;TCDL=6.0psf;BCDL=6.0psf; h=25ft; Cat. II;Exp C; enclosed;MWFRS(envelope) gable end zone and C-CExterior(2)-1-4-12 to 1-7-4,Interior(1) 1-7-4 to 4-3-4zone;cantileverleft exposed ; endverticalleft exposed; porchleft and right exposed;C-C formembers and forces&MWFRS forreactionsshown; Lumber DOL=1.60 plate grip DOL=1.60 2)TCLL:ASCE 7-10;Pr=20.0 psf(roofliveload: Lumber DOL=1.15Plate DOL=1.15);Pg=20.0 psf(groundsnow);Pf=15.4 psf(flat roofsnow: Lumber DOL=1.15Plate DOL=1.15); CategoryII;Exp C; PartiallyExp.; Ct=1.1 3) Unbalancedsnowloads have been considered for this design. 4)This truss has been designed for greater of minroofliveload of 12.0 psf or 2.00 times flatroofload of 15.4 psf on overhangs non-concurrentwith otherliveloads. 5)This truss has been designed for a 10.0 psf bottomchordliveload nonconcurrentwith any otherliveloads. 6) Refer to girder(s) for truss to trussconnections. 7)Providemechanicalconnection(by others) of truss to bearing platecapable of withstanding 100 lb uplift at joint(s) 5, 3, 4. 8)This trussis designedin accordancewith the 2012 InternationalBuilding Code section 2306.1 and referencedstandardANSI/TPI 1. LOADCASE(S)Standard DE Job # 59223-W1 Dansco Engineering, LLC Date: 6/13/18 WARNING – VERIFY DESIGN PARAMETERS AND READ NOTES BEFORE FABRICATION AND INSTALLATION!!! This truss design is adequate for the design parameters shown. Review and approval of design parameters is the responsibility of the building designer, not the truss designer or truss engineer. Permanent bracing requirements against out-of-plane buckling are noted/shown for individual truss members (and for the truss as a whole) subjected to gravity and wind loads. Additional permanent bracing design shall be the responsibility of the design professional of record. Temporary and erection bracing shall be the responsibility of the contractor. Reference ANSI/TPI-1, “National Design Standard for Metal Plate Connected Wood Truss Construction” and TPI/WTCA BCSI-06, “Building Component Safety Information Guide to Good Practice for Handling, Installing, Restraining and Bracing of Metal Plate Connected Wood Trusses” for additional information. Job 1802242-12T Truss J25 TrussType Jack-Open Qty 8 Ply 1 1802242-12TDWHWoodside-West Clay- 4 Job Reference (optional)Run:8.200 s Apr72018 Print:8.200 s Apr72018MiTekIndustries,Inc.Tue Jun1221:11:362018 Page1ID:bRTO9oDnRLEHvJjVgeMKW3yF_s1-N5Z6ic1zCPxy5lZwvhwAjHTfdNfZbYr2197WdIz6wGr Scale=1:18.0 W1 T1 B1 1 2 5 6 7 3 4 3x4 1.5x4 4-9-0 4-9-0 -1-2-12 1-2-12 4-9-0 4-9-0 1 -0 -9 3 -0 -5 2 -7 -14 3 -0 -5 5.0012 LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 10.0 SPACING- PlateGrip DOL Lumber DOL RepStressIncr Code 2-0-0 1.15 1.15 YES IBC2012/TPI2007 CSI. TC BC WB Matrix-MR 0.33 0.20 0.00 DEFL. Vert(LL) Vert(TL) Horz(TL) in 0.03 -0.06 -0.03 (loc) 4-5 4-5 3 l/defl >999 >982 n/a L/d 240 180 n/a PLATES MT20 Weight: 14 lb FT= 20% GRIP 197/144 LUMBER- TOP CHORD2x4SPF No.2 BOT CHORD2x4SPF No.2WEBS2x4SPFStud BRACING- TOP CHORD Structuralwoodsheathing directly applied or 4-9-0 oc purlins, except end verticals.BOT CHORD Rigidceiling directly applied or 10-0-0 oc bracing. MiTekrecommends that Stabilizers and requiredcross bracing beinstalled during truss erection,in accordancewithStabilizer Installation guide.REACTIONS.(lb/size)5=241/0-6-0(min. 0-1-8), 3=102/Mechanical, 4=49/Mechanical Max Horz5=86(LC 16) Max Uplift5=-43(LC 16), 3=-75(LC 16)MaxGrav5=277(LC 2), 3=119(LC 2), 4=85(LC 7) FORCES.(lb)-Max. Comp./Max.Ten.-All forces 250 (lb) orless exceptwhenshown. NOTES- 1)Wind:ASCE 7-10;Vult=115mph(3-second gust)Vasd=91mph;TCDL=6.0psf;BCDL=6.0psf; h=25ft; Cat. II;Exp C; enclosed;MWFRS(envelope) gable end zone and C-CExterior(2)-1-2-12 to 1-9-4,Interior(1) 1-9-4 to 4-8-4zone;cantileverleft and right exposed ; end verticalleft and right exposed;C-C formembers and forces&MWFRS forreactionsshown; Lumber DOL=1.60 plate grip DOL=1.60 2)TCLL:ASCE 7-10;Pr=20.0 psf(roofliveload: Lumber DOL=1.15Plate DOL=1.15);Pg=20.0 psf(groundsnow);Pf=15.4 psf(flat roofsnow: Lumber DOL=1.15Plate DOL=1.15); CategoryII;Exp C; PartiallyExp.; Ct=1.1 3) Unbalancedsnowloads have been considered for this design. 4)This truss has been designed for greater of minroofliveload of 12.0 psf or 2.00 times flatroofload of 15.4 psf on overhangs non-concurrentwith otherliveloads. 5)This truss has been designed for a 10.0 psf bottomchordliveload nonconcurrentwith any otherliveloads. 6) Refer to girder(s) for truss to trussconnections. 7)Providemechanicalconnection(by others) of truss to bearing platecapable of withstanding 100 lb uplift at joint(s) 5, 3. 8)This trussis designedin accordancewith the 2012 InternationalBuilding Code section 2306.1 and referencedstandardANSI/TPI 1. LOADCASE(S)Standard DE Job # 59223-W1 Dansco Engineering, LLC Date: 6/13/18 WARNING – VERIFY DESIGN PARAMETERS AND READ NOTES BEFORE FABRICATION AND INSTALLATION!!! This truss design is adequate for the design parameters shown. Review and approval of design parameters is the responsibility of the building designer, not the truss designer or truss engineer. Permanent bracing requirements against out-of-plane buckling are noted/shown for individual truss members (and for the truss as a whole) subjected to gravity and wind loads. Additional permanent bracing design shall be the responsibility of the design professional of record. Temporary and erection bracing shall be the responsibility of the contractor. Reference ANSI/TPI-1, “National Design Standard for Metal Plate Connected Wood Truss Construction” and TPI/WTCA BCSI-06, “Building Component Safety Information Guide to Good Practice for Handling, Installing, Restraining and Bracing of Metal Plate Connected Wood Trusses” for additional information. Job 1802242-12T Truss J26 TrussType Jack-Open Qty 2 Ply 1 1802242-12TDWHWoodside-West Clay- 4 Job Reference (optional)Run:8.200 s Apr72018 Print:8.200 s Apr72018MiTekIndustries,Inc.Tue Jun1221:11:372018 Page1ID:bRTO9oDnRLEHvJjVgeMKW3yF_s1-rH7Uwy2bzj3pjv86SORPGU?tCn1vK?4CFpt39lz6wGq Scale=1:13.7 W1 T1 B1 1 2 5 6 7 3 4 2x4 2x4 2-7-15 2-7-15 -1-2-12 1-2-12 2-7-15 2-7-15 1 -0 -9 2 -1 -14 1 -9 -7 2 -1 -14 5.0012 LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 10.0 SPACING- PlateGrip DOL Lumber DOL RepStressIncr Code 2-0-0 1.15 1.15 YES IBC2012/TPI2007 CSI. TC BC WB Matrix-MR 0.15 0.07 0.00 DEFL. Vert(LL) Vert(TL) Horz(TL) in -0.00 -0.00 -0.01 (loc) 4-5 4-5 3 l/defl >999 >999 n/a L/d 240 180 n/a PLATES MT20 Weight: 9 lb FT= 20% GRIP 197/144 LUMBER- TOP CHORD2x4SPF No.2 BOT CHORD2x4SPF No.2WEBS2x4SPFStud BRACING- TOP CHORD Structuralwoodsheathing directly applied or 2-7-15 oc purlins, except end verticals.BOT CHORD Rigidceiling directly applied or 10-0-0 oc bracing. MiTekrecommends that Stabilizers and requiredcross bracing beinstalled during truss erection,in accordancewithStabilizer Installation guide.REACTIONS.(lb/size)5=176/0-6-0(min. 0-1-8), 3=46/Mechanical, 4=21/Mechanical Max Horz5=57(LC 13) Max Uplift5=-42(LC 12), 3=-41(LC 16)MaxGrav5=204(LC 2), 3=54(LC 2), 4=45(LC 7) FORCES.(lb)-Max. Comp./Max.Ten.-All forces 250 (lb) orless exceptwhenshown. NOTES- 1)Wind:ASCE 7-10;Vult=115mph(3-second gust)Vasd=91mph;TCDL=6.0psf;BCDL=6.0psf; h=25ft; Cat. II;Exp C; enclosed;MWFRS(envelope) gable end zone and C-CExterior(2)-1-2-12 to 1-9-4,Interior(1) 1-9-4 to 2-7-3zone;cantileverleft and right exposed ; end verticalleft and right exposed;C-C formembers and forces&MWFRS forreactionsshown; Lumber DOL=1.60 plate grip DOL=1.60 2)TCLL:ASCE 7-10;Pr=20.0 psf(roofliveload: Lumber DOL=1.15Plate DOL=1.15);Pg=20.0 psf(groundsnow);Pf=15.4 psf(flat roofsnow: Lumber DOL=1.15Plate DOL=1.15); CategoryII;Exp C; PartiallyExp.; Ct=1.1 3) Unbalancedsnowloads have been considered for this design. 4)This truss has been designed for greater of minroofliveload of 12.0 psf or 2.00 times flatroofload of 15.4 psf on overhangs non-concurrentwith otherliveloads. 5)This truss has been designed for a 10.0 psf bottomchordliveload nonconcurrentwith any otherliveloads. 6) Refer to girder(s) for truss to trussconnections. 7)Providemechanicalconnection(by others) of truss to bearing platecapable of withstanding 100 lb uplift at joint(s) 5, 3. 8)This trussis designedin accordancewith the 2012 InternationalBuilding Code section 2306.1 and referencedstandardANSI/TPI 1. LOADCASE(S)Standard DE Job # 59223-W1 Dansco Engineering, LLC Date: 6/13/18 WARNING – VERIFY DESIGN PARAMETERS AND READ NOTES BEFORE FABRICATION AND INSTALLATION!!! This truss design is adequate for the design parameters shown. Review and approval of design parameters is the responsibility of the building designer, not the truss designer or truss engineer. Permanent bracing requirements against out-of-plane buckling are noted/shown for individual truss members (and for the truss as a whole) subjected to gravity and wind loads. Additional permanent bracing design shall be the responsibility of the design professional of record. Temporary and erection bracing shall be the responsibility of the contractor. Reference ANSI/TPI-1, “National Design Standard for Metal Plate Connected Wood Truss Construction” and TPI/WTCA BCSI-06, “Building Component Safety Information Guide to Good Practice for Handling, Installing, Restraining and Bracing of Metal Plate Connected Wood Trusses” for additional information. Job 1802242-12T Truss J27 TrussType DiagonalHipGirder Qty 1 Ply 1 1802242-12TDWHWoodside-West Clay- 4 Job Reference (optional)Run:8.200 s Apr72018 Print:8.200 s Apr72018MiTekIndustries,Inc.Tue Jun1221:11:382018 Page1ID:bRTO9oDnRLEHvJjVgeMKW3yF_s1-JTht7I3Ek0BgL3jI05zepiYybBI63SKLUTcchBz6wGp Scale=1:17.6 W1 T1 B1 1 2 5 6 3 7 4 3x4 3x4 6-7-2 6-7-2 -1-8-14 1-8-14 3-3-9 3-3-9 6-7-2 3-3-9 1 -0 -9 2 -11 -14 0 -4 -1 2 -7 -13 2 -11 -14 3.5412 LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 10.0 SPACING- PlateGrip DOL Lumber DOL RepStressIncr Code 2-0-0 1.15 1.15 NO IBC2012/TPI2007 CSI. TC BC WB Matrix-MR 0.55 0.39 0.00 DEFL. Vert(LL) Vert(TL) Horz(TL) in -0.08 -0.19 0.06 (loc) 4-5 4-5 3 l/defl >999 >405 n/a L/d 240 180 n/a PLATES MT20 Weight: 18 lb FT= 20% GRIP 197/144 LUMBER- TOP CHORD2x4SPF No.2 BOT CHORD2x4SPF No.2WEBS2x4SPFStud BRACING- TOP CHORD Structuralwoodsheathing directly applied or 6-0-0 oc purlins, except end verticals.BOT CHORD Rigidceiling directly applied or 10-0-0 oc bracing. MiTekrecommends that Stabilizers and requiredcross bracing beinstalled during truss erection,in accordancewithStabilizer Installation guide.REACTIONS.(lb/size)5=238/0-8-2(min. 0-1-8), 3=163/Mechanical, 4=72/Mechanical Max Horz5=81(LC 8) Max Uplift5=-97(LC 8), 3=-106(LC 12)MaxGrav5=274(LC 2), 3=192(LC 2), 4=126(LC 7) FORCES.(lb)-Max. Comp./Max.Ten.-All forces 250 (lb) orless exceptwhenshown. NOTES- 1)Wind:ASCE 7-10;Vult=115mph(3-second gust)Vasd=91mph;TCDL=6.0psf;BCDL=6.0psf; h=25ft; Cat. II;Exp C; enclosed;MWFRS(envelope) gable end zone;cantileverleft exposed ; end verticalleft exposed; Lumber DOL=1.60 plate grip DOL=1.60 2)TCLL:ASCE 7-10;Pr=20.0 psf(roofliveload: Lumber DOL=1.15Plate DOL=1.15);Pg=20.0 psf(groundsnow);Pf=15.4 psf(flat roofsnow: Lumber DOL=1.15Plate DOL=1.15); CategoryII;Exp C; PartiallyExp.; Ct=1.1 3) Unbalancedsnowloads have been considered for this design. 4)This truss has been designed for greater of minroofliveload of 12.0 psf or 2.00 times flatroofload of 15.4 psf on overhangs non-concurrentwith otherliveloads. 5)This truss has been designed for a 10.0 psf bottomchordliveload nonconcurrentwith any otherliveloads. 6) Refer to girder(s) for truss to trussconnections. 7)Providemechanicalconnection(by others) of truss to bearing platecapable of withstanding 100 lb uplift at joint(s) 5 except(jt=lb) 3=106. 8)This trussis designedin accordancewith the 2012 InternationalBuilding Code section 2306.1 and referencedstandardANSI/TPI 1. 9) Hanger(s) or otherconnection device(s)shall be providedsufficient to supportconcentratedload(s) 20 lb down and 36 lb up at 3-10-4, and 20 lb down and 36 lb up at 3-10-4 on top chord, and 5 lb down and 8 lb up at 3-10-4, and 5 lb down and 8 lb up at 3-10-4 on bottomchord.The design/selection of suchconnection device(s)is the responsibility of others. 10)In the LOAD CASE(S)section,loads applied to the face of the truss are noted as front(F) or back(B). LOADCASE(S)Standard 1) Dead +Snow(balanced): LumberIncrease=1.15,PlateIncrease=1.15 Uniform Loads(plf)Vert: 1-2=-51 Concentrated Loads(lb) Vert: 7=0(F=0,B=0)Trapezoidal Loads(plf) Vert: 2=-2(F=24,B=24)-to-3=-84(F=-16,B=-16), 5=0(F=10,B=10)-to-4=-33(F=-6,B=-6) DE Job # 59223-W1 Dansco Engineering, LLC Date: 6/13/18 WARNING – VERIFY DESIGN PARAMETERS AND READ NOTES BEFORE FABRICATION AND INSTALLATION!!! This truss design is adequate for the design parameters shown. Review and approval of design parameters is the responsibility of the building designer, not the truss designer or truss engineer. Permanent bracing requirements against out-of-plane buckling are noted/shown for individual truss members (and for the truss as a whole) subjected to gravity and wind loads. Additional permanent bracing design shall be the responsibility of the design professional of record. Temporary and erection bracing shall be the responsibility of the contractor. Reference ANSI/TPI-1, “National Design Standard for Metal Plate Connected Wood Truss Construction” and TPI/WTCA BCSI-06, “Building Component Safety Information Guide to Good Practice for Handling, Installing, Restraining and Bracing of Metal Plate Connected Wood Trusses” for additional information. Job 1802242-12T Truss PB01 TrussType Piggyback Qty 1 Ply 1 1802242-12TDWHWoodside-West Clay- 4 Job Reference (optional)Run:8.200 s Apr72018 Print:8.200 s Apr72018MiTekIndustries,Inc.Tue Jun1221:11:392018 Page1ID:bRTO9oDnRLEHvJjVgeMKW3yF_s1-ngFFKe3sVKJWyDIVapUtLv5DBbgmovkVj7MAEdz6wGo Scale=1:21.2 0 -1 -14 0 -1 -14 T1 T2 T1 B1 ST1 1 2 3 4 5 6 7 8 9 10 11 12 13 14 3x4 3x4 3x4 3x41.5x4 1.5x4 12-2-0 12-2-0 4-0-14 4-0-14 8-1-2 4-0-4 12-2-0 4-0-14 0 -4 -3 1 -10 -9 2 -0 -7 0 -1 -10 0 -4 -3 0 -1 -10 6.0012 PlateOffsets(X,Y)-- [3:0-2-0,Edge], [5:0-2-0,Edge] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 10.0 SPACING- PlateGrip DOL Lumber DOL RepStressIncr Code 2-0-0 1.15 1.15 YES IBC2012/TPI2007 CSI. TC BC WB Matrix-SH 0.18 0.24 0.05 DEFL. Vert(LL) Vert(TL) Horz(TL) in 0.01 0.02 0.01 (loc) 7 7 6 l/defl n/r n/r n/a L/d 120 120 n/a PLATES MT20 Weight: 28 lb FT= 20% GRIP 197/144 LUMBER- TOP CHORD2x4SPF No.2BOT CHORD2x4SPF No.2 OTHERS 2x4SPFStud BRACING- TOP CHORD Structuralwoodsheathing directly applied or 6-0-0 oc purlins.BOT CHORD Rigidceiling directly applied or 10-0-0 oc bracing. MiTekrecommends that Stabilizers and requiredcross bracing beinstalled during truss erection,in accordancewithStabilizer Installation guide.REACTIONS.(lb/size)2=263/10-2-14(min. 0-1-8), 6=263/10-2-14(min. 0-1-8), 8=302/10-2-14(min. 0-1-8) Max Horz2=31(LC 20) Max Uplift2=-78(LC 16), 6=-79(LC 17), 8=-1(LC 13)MaxGrav2=376(LC 39), 6=376(LC 39), 8=371(LC 38) FORCES.(lb)-Max. Comp./Max.Ten.-All forces 250 (lb) orless exceptwhenshown.TOP CHORD 2-9=-389/191, 9-10=-342/196, 3-10=-310/204, 3-11=-307/211, 4-11=-309/210, 4-12=-309/210, 5-12=-307/211, 5-13=-310/204, 13-14=-342/196, 6-14=-389/191 BOT CHORD 2-8=-120/308, 6-8=-120/308 NOTES- 1) Unbalancedroofliveloads have been considered for this design. 2)Wind:ASCE 7-10;Vult=115mph(3-second gust)Vasd=91mph;TCDL=6.0psf;BCDL=6.0psf; h=25ft; Cat. II;Exp C; enclosed; MWFRS(envelope) gable end zone and C-CExterior(2) 0-4-3 to 3-4-3,Interior(1) 3-4-3 to 4-0-14,Exterior(2) 4-0-14 to 8-1-2zone; cantileverleft and right exposed ; end verticalleft and right exposed;C-C formembers and forces&MWFRS forreactionsshown; Lumber DOL=1.60 plate grip DOL=1.60 3)TCLL:ASCE 7-10;Pr=20.0 psf(roofliveload: Lumber DOL=1.15Plate DOL=1.15);Pg=20.0 psf(groundsnow);Pf=20.4 psf(flat roofsnow: Lumber DOL=1.15Plate DOL=1.15); CategoryII;Exp C; PartiallyExp.; Ct=1.1, Lu=50-0-0;Min. flatroofsnowload governs. Rainsurcharge applied to all exposedsurfaceswithslopesless than 0.500/12 in accordancewithIBC 1608.3.4. 4) Unbalancedsnowloads have been considered for this design. 5)This truss has been designed for greater of minroofliveload of 12.0 psf or 2.00 times flatroofload of 15.4 psf on overhangs non-concurrentwith otherliveloads.6)Provide adequate drainage to preventwater ponding. 7)Gablerequirescontinuous bottomchord bearing. 8)This truss has been designed for a 10.0 psf bottomchordliveload nonconcurrentwith any otherliveloads.9)Providemechanicalconnection(by others) of truss to bearing platecapable of withstanding 100 lb uplift at joint(s) 2, 6, 8. 10)This trussis designedin accordancewith the 2012 InternationalBuilding Code section 2306.1 and referencedstandardANSI/TPI 1.11)SeeStandardIndustryPiggybackTruss Connection Detail for Connection to base truss as applicable, orconsult qualified building designer. LOADCASE(S)Standard DE Job # 59223-W1 Dansco Engineering, LLC Date: 6/13/18 WARNING – VERIFY DESIGN PARAMETERS AND READ NOTES BEFORE FABRICATION AND INSTALLATION!!! This truss design is adequate for the design parameters shown. Review and approval of design parameters is the responsibility of the building designer, not the truss designer or truss engineer. Permanent bracing requirements against out-of-plane buckling are noted/shown for individual truss members (and for the truss as a whole) subjected to gravity and wind loads. Additional permanent bracing design shall be the responsibility of the design professional of record. Temporary and erection bracing shall be the responsibility of the contractor. Reference ANSI/TPI-1, “National Design Standard for Metal Plate Connected Wood Truss Construction” and TPI/WTCA BCSI-06, “Building Component Safety Information Guide to Good Practice for Handling, Installing, Restraining and Bracing of Metal Plate Connected Wood Trusses” for additional information. Job 1802242-12T Truss PB02 TrussType Piggyback Qty 9 Ply 1 1802242-12TDWHWoodside-West Clay- 4 Job Reference (optional)Run:8.200 s Apr72018 Print:8.200 s Apr72018MiTekIndustries,Inc.Tue Jun1221:11:402018 Page1ID:bRTO9oDnRLEHvJjVgeMKW3yF_s1-GspdY_4UFeRNaNsh8W?6u7dK5?0EXLmeyn5jm3z6wGn Scale=1:20.9 T1 T1 B1 ST1 1 2 3 4 5 6 7 8 9 10 4x4 3x4 3x41.5x4 12-2-0 12-2-0 6-1-0 6-1-0 12-2-0 6-1-0 0 -4 -3 3 -0 -8 0 -1 -10 0 -4 -3 0 -1 -10 6.0012 LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 10.0 SPACING- PlateGrip DOL Lumber DOL RepStressIncr Code 2-0-0 1.15 1.15 YES IBC2012/TPI2007 CSI. TC BC WB Matrix-P 0.42 0.22 0.07 DEFL. Vert(LL) Vert(TL) Horz(TL) in 0.03 0.05 0.00 (loc) 5 5 4 l/defl n/r n/r n/a L/d 120 120 n/a PLATES MT20 Weight: 30 lb FT= 20% GRIP 197/144 LUMBER- TOP CHORD2x4SPF No.2 BOT CHORD2x4SPF No.2OTHERS2x4SPFStud BRACING- TOP CHORD Structuralwoodsheathing directly applied or 6-0-0 oc purlins. BOT CHORD Rigidceiling directly applied or 10-0-0 oc bracing. MiTekrecommends that Stabilizers and requiredcross bracing beinstalled during truss erection,in accordancewithStabilizer Installation guide. REACTIONS.(lb/size)2=216/10-2-14(min. 0-1-8), 4=216/10-2-14(min. 0-1-8), 6=356/10-2-14(min. 0-1-8)Max Horz2=51(LC 16) Max Uplift2=-70(LC 16), 4=-80(LC 17), 6=-4(LC 16) MaxGrav2=248(LC 2), 4=248(LC 2), 6=397(LC 2) FORCES.(lb)-Max. Comp./Max.Ten.-All forces 250 (lb) orless exceptwhenshown. WEBS 3-6=-269/115 NOTES- 1) Unbalancedroofliveloads have been considered for this design.2)Wind:ASCE 7-10;Vult=115mph(3-second gust)Vasd=91mph;TCDL=6.0psf;BCDL=6.0psf; h=25ft; Cat. II;Exp C; enclosed; MWFRS(envelope) gable end zone and C-CExterior(2) 0-4-3 to 3-4-3,Interior(1) 3-4-3 to 6-1-0,Exterior(2) 6-1-0 to 9-1-0zone; cantileverleft and right exposed ; end verticalleft and right exposed;C-C formembers and forces&MWFRS forreactionsshown; Lumber DOL=1.60 plate grip DOL=1.60 3)TCLL:ASCE 7-10;Pr=20.0 psf(roofliveload: Lumber DOL=1.15Plate DOL=1.15);Pg=20.0 psf(groundsnow);Pf=15.4 psf(flat roofsnow: Lumber DOL=1.15Plate DOL=1.15); CategoryII;Exp C; PartiallyExp.; Ct=1.1 4) Unbalancedsnowloads have been considered for this design. 5)This truss has been designed for greater of minroofliveload of 12.0 psf or 2.00 times flatroofload of 15.4 psf on overhangs non-concurrentwith otherliveloads. 6)Gablerequirescontinuous bottomchord bearing. 7)This truss has been designed for a 10.0 psf bottomchordliveload nonconcurrentwith any otherliveloads. 8)Providemechanicalconnection(by others) of truss to bearing platecapable of withstanding 100 lb uplift at joint(s) 2, 4, 6. 9)This trussis designedin accordancewith the 2012 InternationalBuilding Code section 2306.1 and referencedstandardANSI/TPI 1.10)SeeStandardIndustryPiggybackTruss Connection Detail for Connection to base truss as applicable, orconsult qualified building designer. LOADCASE(S)Standard DE Job # 59223-W1 Dansco Engineering, LLC Date: 6/13/18 WARNING – VERIFY DESIGN PARAMETERS AND READ NOTES BEFORE FABRICATION AND INSTALLATION!!! This truss design is adequate for the design parameters shown. Review and approval of design parameters is the responsibility of the building designer, not the truss designer or truss engineer. Permanent bracing requirements against out-of-plane buckling are noted/shown for individual truss members (and for the truss as a whole) subjected to gravity and wind loads. Additional permanent bracing design shall be the responsibility of the design professional of record. Temporary and erection bracing shall be the responsibility of the contractor. Reference ANSI/TPI-1, “National Design Standard for Metal Plate Connected Wood Truss Construction” and TPI/WTCA BCSI-06, “Building Component Safety Information Guide to Good Practice for Handling, Installing, Restraining and Bracing of Metal Plate Connected Wood Trusses” for additional information. Job 1802242-12T Truss PB03 TrussType Piggyback Qty 1 Ply 1 1802242-12TDWHWoodside-West Clay- 4 Job Reference (optional)Run:8.200 s Apr72018 Print:8.200 s Apr72018MiTekIndustries,Inc.Tue Jun1221:11:412018 Page1ID:bRTO9oDnRLEHvJjVgeMKW3yF_s1-k2N?lK560xZECXRthEWLQKAXSOMEGpGoARrHIWz6wGm Scale=1:21.2 0 -1 -14 0 -1 -14 T1 T2 T1 B1 ST1 1 2 3 4 5 6 7 8 9 10 11 12 13 14 3x4 3x4 3x4 3x41.5x4 1.5x4 12-2-0 12-2-0 4-2-6 4-2-6 7-11-10 3-9-4 12-2-0 4-2-6 0 -4 -3 1 -11 -5 2 -1 -3 0 -1 -10 0 -4 -3 0 -1 -10 6.0012 PlateOffsets(X,Y)-- [3:0-2-0,Edge], [5:0-2-0,Edge] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 10.0 SPACING- PlateGrip DOL Lumber DOL RepStressIncr Code 2-0-0 1.15 1.15 YES IBC2012/TPI2007 CSI. TC BC WB Matrix-SH 0.19 0.24 0.05 DEFL. Vert(LL) Vert(TL) Horz(TL) in 0.01 0.02 0.01 (loc) 7 7 6 l/defl n/r n/r n/a L/d 120 120 n/a PLATES MT20 Weight: 28 lb FT= 20% GRIP 197/144 LUMBER- TOP CHORD2x4SPF No.2BOT CHORD2x4SPF No.2 OTHERS 2x4SPFStud BRACING- TOP CHORD Structuralwoodsheathing directly applied or 6-0-0 oc purlins.BOT CHORD Rigidceiling directly applied or 10-0-0 oc bracing. MiTekrecommends that Stabilizers and requiredcross bracing beinstalled during truss erection,in accordancewithStabilizer Installation guide.REACTIONS.(lb/size)2=265/10-2-14(min. 0-1-9), 6=265/10-2-14(min. 0-1-9), 8=295/10-2-14(min. 0-1-9) Max Horz2=-33(LC 21) Max Uplift2=-80(LC 16), 6=-81(LC 17)MaxGrav2=385(LC 39), 6=385(LC 39), 8=360(LC 38) FORCES.(lb)-Max. Comp./Max.Ten.-All forces 250 (lb) orless exceptwhenshown.TOP CHORD 2-9=-399/192, 9-10=-351/196, 3-10=-320/205, 3-11=-315/212, 4-11=-317/212, 4-12=-317/212, 5-12=-315/213, 5-13=-320/205, 13-14=-351/196, 6-14=-399/192 BOT CHORD 2-8=-119/315, 6-8=-119/315 NOTES- 1) Unbalancedroofliveloads have been considered for this design. 2)Wind:ASCE 7-10;Vult=115mph(3-second gust)Vasd=91mph;TCDL=6.0psf;BCDL=6.0psf; h=25ft; Cat. II;Exp C; enclosed; MWFRS(envelope) gable end zone and C-CExterior(2) 0-4-3 to 3-4-3,Interior(1) 3-4-3 to 4-2-6,Exterior(2) 4-2-6 to 7-11-10zone; cantileverleft and right exposed ; end verticalleft and right exposed;C-C formembers and forces&MWFRS forreactionsshown; Lumber DOL=1.60 plate grip DOL=1.60 3)TCLL:ASCE 7-10;Pr=20.0 psf(roofliveload: Lumber DOL=1.15Plate DOL=1.15);Pg=20.0 psf(groundsnow);Pf=20.4 psf(flat roofsnow: Lumber DOL=1.15Plate DOL=1.15); CategoryII;Exp C; PartiallyExp.; Ct=1.1, Lu=50-0-0;Min. flatroofsnowload governs. Rainsurcharge applied to all exposedsurfaceswithslopesless than 0.500/12 in accordancewithIBC 1608.3.4. 4) Unbalancedsnowloads have been considered for this design. 5)This truss has been designed for greater of minroofliveload of 12.0 psf or 2.00 times flatroofload of 15.4 psf on overhangs non-concurrentwith otherliveloads.6)Provide adequate drainage to preventwater ponding. 7)Gablerequirescontinuous bottomchord bearing. 8)This truss has been designed for a 10.0 psf bottomchordliveload nonconcurrentwith any otherliveloads.9)Providemechanicalconnection(by others) of truss to bearing platecapable of withstanding 100 lb uplift at joint(s) 2, 6. 10)This trussis designedin accordancewith the 2012 InternationalBuilding Code section 2306.1 and referencedstandardANSI/TPI 1.11)SeeStandardIndustryPiggybackTruss Connection Detail for Connection to base truss as applicable, orconsult qualified building designer. LOADCASE(S)Standard DE Job # 59223-W1 Dansco Engineering, LLC Date: 6/13/18 WARNING – VERIFY DESIGN PARAMETERS AND READ NOTES BEFORE FABRICATION AND INSTALLATION!!! This truss design is adequate for the design parameters shown. Review and approval of design parameters is the responsibility of the building designer, not the truss designer or truss engineer. Permanent bracing requirements against out-of-plane buckling are noted/shown for individual truss members (and for the truss as a whole) subjected to gravity and wind loads. Additional permanent bracing design shall be the responsibility of the design professional of record. Temporary and erection bracing shall be the responsibility of the contractor. Reference ANSI/TPI-1, “National Design Standard for Metal Plate Connected Wood Truss Construction” and TPI/WTCA BCSI-06, “Building Component Safety Information Guide to Good Practice for Handling, Installing, Restraining and Bracing of Metal Plate Connected Wood Trusses” for additional information. Job 1802242-12T Truss T01 TrussType CommonGirder Qty 1 Ply 2 1802242-12TDWHWoodside-West Clay- 4 Job Reference (optional)Run:8.200 s Apr72018 Print:8.200 s Apr72018MiTekIndustries,Inc.Tue Jun1221:11:422018 Page1ID:bRTO9oDnRLEHvJjVgeMKW3yF_s1-CFxNzf6knFh5pg04Fx1azYjgEoYS?7JxP5aqqyz6wGl Scale=1:47.3 T1 T1 B1 W3 W2 W1W2W1 B1 1 2 3 4 5 6 7 10 9 8 17 18 19 20 21 22 23 24 25 26 5x6 8x8 4x6 3x8 3x10 3x8 3x10 5x6 5-1-12 5-1-12 9-10-0 4-8-4 14-6-4 4-8-4 19-8-0 5-1-12 -1-2-12 1-2-12 5-1-12 5-1-12 9-10-0 4-8-4 14-6-4 4-8-4 19-8-0 5-1-12 20-10-12 1-2-12 0 -5 -12 7 -10 -4 0 -5 -12 9.0012 PlateOffsets(X,Y)-- [2:0-0-0,0-0-10], [6:Edge,0-0-10], [9:0-4-0,0-4-12] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 10.0 SPACING- PlateGrip DOL Lumber DOL RepStressIncr Code 2-0-0 1.15 1.15 NO IBC2012/TPI2007 CSI. TC BC WB Matrix-MSH 0.38 0.88 0.58 DEFL. Vert(LL) Vert(TL) Horz(TL) in -0.09 -0.20 0.06 (loc) 8-9 8-9 6 l/defl >999 >999 n/a L/d 240 180 n/a PLATES MT20 Weight: 193 lb FT= 20% GRIP 197/144 LUMBER- TOP CHORD2x4SPF No.2BOT CHORD2x6SPF No.2 WEBS 2x4SPFStud*Except* W3: 2x4SPF No.2 BRACING- TOP CHORD Structuralwoodsheathing directly applied or 4-9-10 oc purlins.BOT CHORD Rigidceiling directly applied or 10-0-0 oc bracing. REACTIONS.(lb/size)2=4663/0-6-0(min. 0-3-13), 6=4461/0-6-0(min. 0-3-8) Max Horz2=217(LC 11)Max Uplift2=-638(LC 12), 6=-991(LC 13) MaxGrav2=4854(LC 2), 6=4461(LC 1) FORCES.(lb)-Max. Comp./Max.Ten.-All forces 250 (lb) orless exceptwhenshown. TOP CHORD 2-3=-5965/806, 3-17=-4195/686, 4-17=-4122/703, 4-18=-4120/704, 5-18=-4193/674, 5-6=-6187/1081 BOT CHORD 2-19=-664/4728, 19-20=-664/4728, 10-20=-664/4728, 10-21=-664/4728, 21-22=-664/4728, 9-22=-664/4728, 9-23=-788/4895, 23-24=-788/4895, 8-24=-788/4895, 8-25=-788/4895, 25-26=-788/4895, 6-26=-788/4895 WEBS 4-9=-723/4708, 5-9=-2098/636, 5-8=-494/2294, 3-9=-1977/342, 3-10=-149/2091 NOTES- 1) 2-ply truss to be connected togetherwith 10d (0.131"x3") nails as follows: Topchordsconnected as follows: 2x4- 1 row at 0-7-0 oc. Bottomchordsconnected as follows: 2x6- 2 rowsstaggered at 0-7-0 oc. Websconnected as follows: 2x4- 1 row at 0-9-0 oc. 2)Allloads areconsidered equally applied to all plies, exceptif noted as front(F) or back(B) facein the LOAD CASE(S)section.Ply to plyconnections have been provided to distribute onlyloads noted as(F) or(B), unless otherwiseindicated. 3) Unbalancedroofliveloads have been considered for this design.4)Wind:ASCE 7-10;Vult=115mph(3-second gust)Vasd=91mph;TCDL=6.0psf;BCDL=6.0psf; h=25ft; Cat. II;Exp C; enclosed; MWFRS(envelope) gable end zone;cantileverleft and right exposed ; end verticalleft and right exposed; Lumber DOL=1.60 plate grip DOL=1.605)TCLL:ASCE 7-10;Pr=20.0 psf(roofliveload: Lumber DOL=1.15Plate DOL=1.15);Pg=20.0 psf(groundsnow);Pf=15.4 psf(flat roofsnow: Lumber DOL=1.15Plate DOL=1.15); CategoryII;Exp C; PartiallyExp.; Ct=1.1 6) Unbalancedsnowloads have been considered for this design.7)This truss has been designed for greater of minroofliveload of 12.0 psf or 2.00 times flatroofload of 15.4 psf on overhangs non-concurrentwith otherliveloads. 8)This truss has been designed for a 10.0 psf bottomchordliveload nonconcurrentwith any otherliveloads.9)Providemechanicalconnection(by others) of truss to bearing platecapable of withstanding 100 lb uplift at joint(s) except(jt=lb) 2=638, 6=991. 10)This trussis designedin accordancewith the 2012 InternationalBuilding Code section 2306.1 and referencedstandardANSI/TPI 1. Continued on page 2 DE Job # 59223-W1 Dansco Engineering, LLC Date: 6/13/18 WARNING – VERIFY DESIGN PARAMETERS AND READ NOTES BEFORE FABRICATION AND INSTALLATION!!! This truss design is adequate for the design parameters shown. Review and approval of design parameters is the responsibility of the building designer, not the truss designer or truss engineer. Permanent bracing requirements against out-of-plane buckling are noted/shown for individual truss members (and for the truss as a whole) subjected to gravity and wind loads. Additional permanent bracing design shall be the responsibility of the design professional of record. Temporary and erection bracing shall be the responsibility of the contractor. Reference ANSI/TPI-1, “National Design Standard for Metal Plate Connected Wood Truss Construction” and TPI/WTCA BCSI-06, “Building Component Safety Information Guide to Good Practice for Handling, Installing, Restraining and Bracing of Metal Plate Connected Wood Trusses” for additional information. Job 1802242-12T Truss T01 TrussType CommonGirder Qty 1 Ply 2 1802242-12TDWHWoodside-West Clay- 4 Job Reference (optional)Run:8.200 s Apr72018 Print:8.200 s Apr72018MiTekIndustries,Inc.Tue Jun1221:11:422018 Page2ID:bRTO9oDnRLEHvJjVgeMKW3yF_s1-CFxNzf6knFh5pg04Fx1azYjgEoYS?7JxP5aqqyz6wGl NOTES- 11) Hanger(s) or otherconnection device(s)shall be providedsufficient to supportconcentratedload(s) 122 lb down and 121 lb up at 19-9-0 on top chord, and 821 lb down and 89 lb up at 1-0-8, 821 lb down and 89 lb up at 3-0-8, 821 lb down and 89 lb up at 5-0-8, 821 lb down and 89 lb up at 7-0-8, 874 lb down and 104 lb up at 9-0-8, 930 lb down and 156 lb up at 11-0-8, 972 lb down and 150 lb up at 13-0-8, and 953 lb down and 136 lb up at 15-0-8, and 903 lb down and 490 lb up at 17-0-8 on bottomchord.The design/selection of suchconnection device(s)is the responsibility of others. LOADCASE(S)Standard 1) Dead +Snow(balanced): LumberIncrease=1.15,PlateIncrease=1.15 Uniform Loads(plf) Vert: 1-4=-51, 4-7=-51, 11-14=-20 Concentrated Loads(lb) Vert: 10=-741(B) 6=-12(B) 19=-741(B) 20=-741(B) 21=-741(B) 22=-874(B) 23=-930(B) 24=-972(B) 25=-953(B) 26=-903(B) DE Job # 59223-W1 Dansco Engineering, LLC Date: 6/13/18 WARNING – VERIFY DESIGN PARAMETERS AND READ NOTES BEFORE FABRICATION AND INSTALLATION!!! This truss design is adequate for the design parameters shown. Review and approval of design parameters is the responsibility of the building designer, not the truss designer or truss engineer. Permanent bracing requirements against out-of-plane buckling are noted/shown for individual truss members (and for the truss as a whole) subjected to gravity and wind loads. Additional permanent bracing design shall be the responsibility of the design professional of record. Temporary and erection bracing shall be the responsibility of the contractor. Reference ANSI/TPI-1, “National Design Standard for Metal Plate Connected Wood Truss Construction” and TPI/WTCA BCSI-06, “Building Component Safety Information Guide to Good Practice for Handling, Installing, Restraining and Bracing of Metal Plate Connected Wood Trusses” for additional information. Job 1802242-12T Truss T01GE TrussType GABLE Qty 1 Ply 1 1802242-12TDWHWoodside-West Clay- 4 Job Reference (optional)Run:8.200 s Apr72018 Print:8.200 s Apr72018MiTekIndustries,Inc.Tue Jun1221:11:432018 Page1ID:bRTO9oDnRLEHvJjVgeMKW3yF_s1-gRVlA?7MYZpyRqbGpfYpWlFv5C5Tki04elKNNOz6wGk Scale=1:49.9 T1 T1 B1 ST4 ST3 ST2 ST1 ST4 ST3 ST2 ST1 B11 2 3 4 5 6 7 8 9 10 11 12 13 22 21 20 19 18 17 16 15 14 23 24 3x4 3x4 3x4 3x4 19-8-0 19-8-0 -1-2-12 1-2-12 9-10-0 9-10-0 19-8-0 9-10-0 20-10-12 1-2-12 0 -5 -12 7 -10 -4 0 -5 -12 9.0012 PlateOffsets(X,Y)-- [7:0-2-0,Edge] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 10.0 SPACING- PlateGrip DOL Lumber DOL RepStressIncr Code 2-0-0 1.15 1.15 YES IBC2012/TPI2007 CSI. TC BC WB Matrix-SH 0.12 0.06 0.10 DEFL. Vert(LL) Vert(TL) Horz(TL) in -0.00 -0.00 0.00 (loc) 13 13 12 l/defl n/r n/r n/a L/d 120 120 n/a PLATES MT20 Weight: 94 lb FT= 20% GRIP 197/144 LUMBER- TOP CHORD2x4SPF No.2BOT CHORD2x4SPF No.2 OTHERS 2x4SPFStud BRACING- TOP CHORD Structuralwoodsheathing directly applied or 6-0-0 oc purlins.BOT CHORD Rigidceiling directly applied or 6-0-0 oc bracing. MiTekrecommends that Stabilizers and requiredcross bracing beinstalled during truss erection,in accordancewithStabilizer Installation guide.REACTIONS.All bearings 19-8-0. (lb)-Max Horz2=-217(LC 14) Max UpliftAll uplift 100 lb orless at joint(s) 7, 2, 19, 20, 21, 17, 16, 15, 12 except 22=-109(LC 16),14=-106(LC 17) MaxGravAllreactions 250 lb orless at joint(s) 7, 2, 19, 20, 21, 22, 17, 16, 15, 14, 12 FORCES.(lb)-Max. Comp./Max.Ten.-All forces 250 (lb) orless exceptwhenshown. NOTES-1) Unbalancedroofliveloads have been considered for this design. 2)Wind:ASCE 7-10;Vult=115mph(3-second gust)Vasd=91mph;TCDL=6.0psf;BCDL=6.0psf; h=25ft; Cat. II;Exp C; enclosed; MWFRS(envelope) gable end zone and C-C Corner(3)-1-2-12 to 1-9-4,Exterior(2) 1-9-4 to 9-10-0, Corner(3) 9-10-0 to 12-10-0 zone;cantileverleft and right exposed ; end verticalleft and right exposed;C-C formembers and forces&MWFRS forreactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3)Truss designed forwindloadsin the plane of the truss only.Forstuds exposed to wind(normal to the face),seeStandardIndustry GableEnd Details as applicable, orconsult qualified building designer as perANSI/TPI 1. 4)TCLL:ASCE 7-10;Pr=20.0 psf(roofliveload: Lumber DOL=1.15Plate DOL=1.15);Pg=20.0 psf(groundsnow);Pf=15.4 psf(flat roofsnow: Lumber DOL=1.15Plate DOL=1.15); CategoryII;Exp C; PartiallyExp.; Ct=1.1 5) Unbalancedsnowloads have been considered for this design. 6)This truss has been designed for greater of minroofliveload of 12.0 psf or 2.00 times flatroofload of 15.4 psf on overhangs non-concurrentwith otherliveloads. 7)All plates are 1.5x4MT20 unless otherwiseindicated.8)Gablerequirescontinuous bottomchord bearing. 9)Gablestudsspaced at 2-0-0 oc. 10)This truss has been designed for a 10.0 psf bottomchordliveload nonconcurrentwith any otherliveloads.11)Providemechanicalconnection(by others) of truss to bearing platecapable of withstanding 100 lb uplift at joint(s) 7, 2, 19, 20, 21, 17, 16, 15, 12 except(jt=lb) 22=109, 14=106. 12)This trussis designedin accordancewith the 2012 InternationalBuilding Code section 2306.1 and referencedstandardANSI/TPI1. LOADCASE(S)Standard DE Job # 59223-W1 Dansco Engineering, LLC Date: 6/13/18 WARNING – VERIFY DESIGN PARAMETERS AND READ NOTES BEFORE FABRICATION AND INSTALLATION!!! This truss design is adequate for the design parameters shown. Review and approval of design parameters is the responsibility of the building designer, not the truss designer or truss engineer. Permanent bracing requirements against out-of-plane buckling are noted/shown for individual truss members (and for the truss as a whole) subjected to gravity and wind loads. Additional permanent bracing design shall be the responsibility of the design professional of record. Temporary and erection bracing shall be the responsibility of the contractor. Reference ANSI/TPI-1, “National Design Standard for Metal Plate Connected Wood Truss Construction” and TPI/WTCA BCSI-06, “Building Component Safety Information Guide to Good Practice for Handling, Installing, Restraining and Bracing of Metal Plate Connected Wood Trusses” for additional information. Job 1802242-12T Truss T02GE TrussType Common SupportedGable Qty 1 Ply 1 1802242-12TDWHWoodside-West Clay- 4 Job Reference (optional)Run:8.200 s Apr72018 Print:8.200 s Apr72018MiTekIndustries,Inc.Tue Jun1221:11:442018 Page1ID:bRTO9oDnRLEHvJjVgeMKW3yF_s1-8d28OL7_Jsxp3_ASNM322zo3FcRBTAIEsP3xvrz6wGj Scale=1:24.8 T1 T1 B1 ST2 ST1 ST1 1 2 3 4 5 6 7 10 9 8 11 12 4x4 2x4 2x41.5x41.5x4 1.5x4 1.5x4 1.5x4 7-10-0 7-10-0 -1-4-12 1-4-12 3-11-0 3-11-0 7-10-0 3-11-0 9-2-12 1-4-12 0 -5 -12 3 -5 -0 0 -5 -12 9.0012 PlateOffsets(X,Y)-- [2:0-2-9,0-1-0], [6:0-2-9,0-1-0] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 10.0 SPACING- PlateGrip DOL Lumber DOL RepStressIncr Code 2-0-0 1.15 1.15 YES IBC2012/TPI2007 CSI. TC BC WB Matrix-P 0.16 0.03 0.03 DEFL. Vert(LL) Vert(TL) Horz(TL) in -0.01 -0.02 0.00 (loc) 7 7 6 l/defl n/r n/r n/a L/d 120 120 n/a PLATES MT20 Weight: 31 lb FT= 20% GRIP 197/144 LUMBER- TOP CHORD2x4SPF No.2BOT CHORD2x4SPF No.2 OTHERS 2x4SPFStud BRACING- TOP CHORD Structuralwoodsheathing directly applied or 6-0-0 oc purlins.BOT CHORD Rigidceiling directly applied or 10-0-0 oc bracing. MiTekrecommends that Stabilizers and requiredcross bracing beinstalled during truss erection,in accordancewithStabilizer Installation guide.REACTIONS.All bearings 7-10-0. (lb)-Max Horz2=104(LC 15) Max UpliftAll uplift 100 lb orless at joint(s) 2, 6, 10, 8MaxGravAllreactions 250 lb orless at joint(s) 2, 6, 9, 10, 8 FORCES.(lb)-Max. Comp./Max.Ten.-All forces 250 (lb) orless exceptwhenshown. NOTES- 1) Unbalancedroofliveloads have been considered for this design.2)Wind:ASCE 7-10;Vult=115mph(3-second gust)Vasd=91mph;TCDL=6.0psf;BCDL=6.0psf; h=25ft; Cat. II;Exp C; enclosed; MWFRS(envelope) gable end zone and C-C Corner(3)-1-4-12 to 1-7-4,Exterior(2) 1-7-4 to 3-11-0, Corner(3) 3-11-0 to 6-11-0 zone;cantileverleft and right exposed ; end verticalleft and right exposed;C-C formembers and forces&MWFRS forreactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3)Truss designed forwindloadsin the plane of the truss only.Forstuds exposed to wind(normal to the face),seeStandardIndustry GableEnd Details as applicable, orconsult qualified building designer as perANSI/TPI 1. 4)TCLL:ASCE 7-10;Pr=20.0 psf(roofliveload: Lumber DOL=1.15Plate DOL=1.15);Pg=20.0 psf(groundsnow);Pf=15.4 psf(flat roofsnow: Lumber DOL=1.15Plate DOL=1.15); CategoryII;Exp C; PartiallyExp.; Ct=1.1 5) Unbalancedsnowloads have been considered for this design. 6)This truss has been designed for greater of minroofliveload of 12.0 psf or 2.00 times flatroofload of 15.4 psf on overhangs non-concurrentwith otherliveloads. 7)Gablerequirescontinuous bottomchord bearing. 8)Gablestudsspaced at 2-0-0 oc.9)This truss has been designed for a 10.0 psf bottomchordliveload nonconcurrentwith any otherliveloads. 10)Providemechanicalconnection(by others) of truss to bearing platecapable of withstanding 100 lb uplift at joint(s) 2, 6, 10, 8. 11)Beveled plate orshimrequired to provide full bearingsurfacewith trusschord at joint(s) 2, 6.12)This trussis designedin accordancewith the 2012 InternationalBuilding Code section 2306.1 and referencedstandardANSI/TPI 1. LOADCASE(S)Standard DE Job # 59223-W1 Dansco Engineering, LLC Date: 6/13/18 WARNING – VERIFY DESIGN PARAMETERS AND READ NOTES BEFORE FABRICATION AND INSTALLATION!!! This truss design is adequate for the design parameters shown. Review and approval of design parameters is the responsibility of the building designer, not the truss designer or truss engineer. Permanent bracing requirements against out-of-plane buckling are noted/shown for individual truss members (and for the truss as a whole) subjected to gravity and wind loads. Additional permanent bracing design shall be the responsibility of the design professional of record. Temporary and erection bracing shall be the responsibility of the contractor. Reference ANSI/TPI-1, “National Design Standard for Metal Plate Connected Wood Truss Construction” and TPI/WTCA BCSI-06, “Building Component Safety Information Guide to Good Practice for Handling, Installing, Restraining and Bracing of Metal Plate Connected Wood Trusses” for additional information. Job 1802242-12T Truss T03 TrussType Common Qty 1 Ply 1 1802242-12TDWHWoodside-West Clay- 4 Job Reference (optional)Run:8.200 s Apr72018 Print:8.200 s Apr72018MiTekIndustries,Inc.Tue Jun1221:11:452018 Page1ID:bRTO9oDnRLEHvJjVgeMKW3yF_s1-cqcWbh8d4A3gg8lfw4bHbAKBw0fPCRAN53pURHz6wGi Scale=1:55.4 T2 T2 B1 W2 W1 W2 W1T1 T1 B21 2 3 4 5 6 7 8 9 12 11 10 19 20 21 22 23 24 3x4 4x6 3x4 3x5 3x4 3x4 1.5x4 3x4 1.5x4 3x5 7-8-15 7-8-15 15-3-1 7-6-2 23-0-0 7-8-15 -1-4-12 1-4-12 5-10-7 5-10-7 11-6-0 5-7-9 17-1-9 5-7-9 23-0-0 5-10-7 24-4-12 1-4-12 0 -5 -12 9 -1 -4 0 -5 -12 9.0012 PlateOffsets(X,Y)-- [2:0-0-0,0-0-3], [8:Edge,0-0-3] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 10.0 SPACING- PlateGrip DOL Lumber DOL RepStressIncr Code 2-0-0 1.15 1.15 YES IBC2012/TPI2007 CSI. TC BC WB Matrix-MSH 0.35 0.48 0.83 DEFL. Vert(LL) Vert(TL) Horz(TL) in 0.14 -0.19 0.03 (loc) 10-18 12-15 8 l/defl >999 >999 n/a L/d 240 180 n/a PLATES MT20 Weight: 95 lb FT= 20% GRIP 197/144 LUMBER- TOP CHORD2x4SPF No.2BOT CHORD2x4SPF No.2 WEBS 2x4SPF No.2 *Except* W1: 2x4SPFStud BRACING- TOP CHORD Structuralwoodsheathing directly applied or 5-2-5 oc purlins.BOT CHORD Rigidceiling directly applied or 7-8-6 oc bracing. MiTekrecommends that Stabilizers and requiredcross bracing beinstalled during truss erection,in accordancewithStabilizer Installation guide.REACTIONS.(lb/size)2=885/0-4-0(min. 0-1-9), 8=885/0-4-0(min. 0-1-9) Max Horz2=253(LC 15) Max Uplift2=-146(LC 16), 8=-146(LC 17)MaxGrav2=1004(LC 2), 8=1004(LC 2) FORCES.(lb)-Max. Comp./Max.Ten.-All forces 250 (lb) orless exceptwhenshown.TOP CHORD 2-19=-1225/770, 3-19=-1134/800, 3-4=-1096/852, 4-20=-999/867, 20-21=-986/870, 5-21=-983/889, 5-22=-983/889, 22-23=-986/870, 6-23=-999/867, 6-7=-1096/852, 7-24=-1134/800, 8-24=-1225/770BOT CHORD 2-12=-520/907, 11-12=-244/600, 10-11=-244/600, 8-10=-531/907 WEBS 5-10=-513/491, 7-10=-365/266, 5-12=-513/491, 3-12=-365/266 NOTES- 1) Unbalancedroofliveloads have been considered for this design. 2)Wind:ASCE 7-10;Vult=115mph(3-second gust)Vasd=91mph;TCDL=6.0psf;BCDL=6.0psf; h=25ft; Cat. II;Exp C; enclosed; MWFRS(envelope) gable end zone and C-CExterior(2)-1-4-12 to 1-7-4,Interior(1) 1-7-4 to 11-6-0,Exterior(2) 11-6-0 to 14-6-0 zone;cantileverleft and right exposed ; end verticalleft and right exposed; porchleft and right exposed;C-C formembers and forces &MWFRS forreactionsshown; Lumber DOL=1.60 plate grip DOL=1.60 3)TCLL:ASCE 7-10;Pr=20.0 psf(roofliveload: Lumber DOL=1.15Plate DOL=1.15);Pg=20.0 psf(groundsnow);Pf=15.4 psf(flat roofsnow: Lumber DOL=1.15Plate DOL=1.15); CategoryII;Exp C; PartiallyExp.; Ct=1.1 4) Unbalancedsnowloads have been considered for this design. 5)This truss has been designed for greater of minroofliveload of 12.0 psf or 2.00 times flatroofload of 15.4 psf on overhangsnon-concurrentwith otherliveloads. 6)This truss has been designed for a 10.0 psf bottomchordliveload nonconcurrentwith any otherliveloads. 7)Providemechanicalconnection(by others) of truss to bearing platecapable of withstanding 100 lb uplift at joint(s) except(jt=lb)2=146, 8=146. 8)This trussis designedin accordancewith the 2012 InternationalBuilding Code section 2306.1 and referencedstandardANSI/TPI 1. LOADCASE(S)Standard DE Job # 59223-W1 Dansco Engineering, LLC Date: 6/13/18 WARNING – VERIFY DESIGN PARAMETERS AND READ NOTES BEFORE FABRICATION AND INSTALLATION!!! This truss design is adequate for the design parameters shown. Review and approval of design parameters is the responsibility of the building designer, not the truss designer or truss engineer. Permanent bracing requirements against out-of-plane buckling are noted/shown for individual truss members (and for the truss as a whole) subjected to gravity and wind loads. Additional permanent bracing design shall be the responsibility of the design professional of record. Temporary and erection bracing shall be the responsibility of the contractor. Reference ANSI/TPI-1, “National Design Standard for Metal Plate Connected Wood Truss Construction” and TPI/WTCA BCSI-06, “Building Component Safety Information Guide to Good Practice for Handling, Installing, Restraining and Bracing of Metal Plate Connected Wood Trusses” for additional information. Job 1802242-12T Truss T03GE TrussType Common StructuralGable Qty 1 Ply 1 1802242-12TDWHWoodside-West Clay- 4 Job Reference (optional)Run:8.200 s Apr72018 Print:8.200 s Apr72018MiTekIndustries,Inc.Tue Jun1221:11:462018 Page1ID:bRTO9oDnRLEHvJjVgeMKW3yF_s1-40Aup19FrUBXIIKrUn6W7OtMgP?exuQXKjY2zjz6wGh Scale=1:58.7 T2 T2 B1 W5 W4 W5 W4 ST7 ST5 ST6 ST4 ST3 ST2ST1 ST5 ST6 ST4 ST3 ST2 ST1 W2 W1 W3 T1 T1 B21 2 3 4 5 6 7 8 9 12 11 10 48 49 50 51 52 53 3x4 4x6 3x4 3x4 3x5 3x4 3x4 3x4 3x5 7-8-15 7-8-15 11-6-0 3-9-1 15-3-1 3-9-1 23-0-0 7-8-15 -1-4-12 1-4-12 5-10-7 5-10-7 11-6-0 5-7-9 17-1-9 5-7-9 23-0-0 5-10-7 24-4-12 1-4-12 0 -5 -12 9 -1 -4 0 -5 -12 9.0012 PlateOffsets(X,Y)-- [2:0-0-0,0-0-3], [5:0-1-3,0-1-8], [8:Edge,0-0-3] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 10.0 SPACING- PlateGrip DOL Lumber DOL RepStressIncr Code 2-0-0 1.15 1.15 YES IBC2012/TPI2007 CSI. TC BC WB Matrix-MSH 0.35 0.48 0.83 DEFL. Vert(LL) Vert(TL) Horz(TL) in 0.14 -0.19 0.03 (loc) 10-47 12-44 8 l/defl >999 >999 n/a L/d 240 180 n/a PLATES MT20 Weight: 152 lb FT= 20% GRIP 197/144 LUMBER- TOP CHORD2x4SPF No.2BOT CHORD2x4SPF No.2 WEBS 2x4SPFStud*Except* W5: 2x4SPF No.2OTHERS2x4SPFStud BRACING- TOP CHORD Structuralwoodsheathing directly applied or 5-2-5 oc purlins.BOT CHORD Rigidceiling directly applied or 7-8-6 oc bracing. MiTekrecommends that Stabilizers and requiredcross bracing beinstalled during truss erection,in accordancewithStabilizer Installation guide. REACTIONS.(lb/size)2=885/0-4-0(min. 0-1-9), 8=885/0-4-0(min. 0-1-9)Max Horz2=253(LC 15) Max Uplift2=-146(LC 16), 8=-146(LC 17) MaxGrav2=1004(LC 2), 8=1004(LC 2) FORCES.(lb)-Max. Comp./Max.Ten.-All forces 250 (lb) orless exceptwhenshown. TOP CHORD 2-48=-1225/770, 3-48=-1134/800, 3-4=-1096/852, 4-49=-999/867, 49-50=-986/870, 5-50=-983/889, 5-51=-983/889, 51-52=-986/870, 6-52=-999/867, 6-7=-1096/852, 7-53=-1134/800, 8-53=-1225/770 BOT CHORD 2-12=-520/907, 11-12=-244/600, 10-11=-244/600, 8-10=-531/907 WEBS 5-10=-513/491, 7-10=-365/266, 5-12=-513/491, 3-12=-365/266 NOTES- 1) Unbalancedroofliveloads have been considered for this design. 2)Wind:ASCE 7-10;Vult=115mph(3-second gust)Vasd=91mph;TCDL=6.0psf;BCDL=6.0psf; h=25ft; Cat. II;Exp C; enclosed; MWFRS(envelope) gable end zone and C-CExterior(2)-1-4-12 to 1-7-4,Interior(1) 1-7-4 to 11-6-0,Exterior(2) 11-6-0 to 14-6-0 zone;cantileverleft and right exposed ; end verticalleft and right exposed; porchleft and right exposed;C-C formembers and forces &MWFRS forreactionsshown; Lumber DOL=1.60 plate grip DOL=1.60 3)Truss designed forwindloadsin the plane of the truss only.Forstuds exposed to wind(normal to the face),seeStandardIndustry GableEnd Details as applicable, orconsult qualified building designer as perANSI/TPI 1.4)TCLL:ASCE 7-10;Pr=20.0 psf(roofliveload: Lumber DOL=1.15Plate DOL=1.15);Pg=20.0 psf(groundsnow);Pf=15.4 psf(flat roofsnow: Lumber DOL=1.15Plate DOL=1.15); CategoryII;Exp C; PartiallyExp.; Ct=1.1 5) Unbalancedsnowloads have been considered for this design.6)This truss has been designed for greater of minroofliveload of 12.0 psf or 2.00 times flatroofload of 15.4 psf on overhangs non-concurrentwith otherliveloads. 7)All plates are 1.5x4MT20 unless otherwiseindicated.8)Vertical gablestudsspaced at 2-0-0 oc and horizontal gablestudsspaced at 4-3-8 oc. 9)This truss has been designed for a 10.0 psf bottomchordliveload nonconcurrentwith any otherliveloads. 10)Providemechanicalconnection(by others) of truss to bearing platecapable of withstanding 100 lb uplift at joint(s) except(jt=lb)2=146, 8=146. 11)This trussis designedin accordancewith the 2012 InternationalBuilding Code section 2306.1 and referencedstandardANSI/TPI 1. LOADCASE(S)Standard DE Job # 59223-W1 Dansco Engineering, LLC Date: 6/13/18 WARNING – VERIFY DESIGN PARAMETERS AND READ NOTES BEFORE FABRICATION AND INSTALLATION!!! This truss design is adequate for the design parameters shown. Review and approval of design parameters is the responsibility of the building designer, not the truss designer or truss engineer. Permanent bracing requirements against out-of-plane buckling are noted/shown for individual truss members (and for the truss as a whole) subjected to gravity and wind loads. Additional permanent bracing design shall be the responsibility of the design professional of record. Temporary and erection bracing shall be the responsibility of the contractor. Reference ANSI/TPI-1, “National Design Standard for Metal Plate Connected Wood Truss Construction” and TPI/WTCA BCSI-06, “Building Component Safety Information Guide to Good Practice for Handling, Installing, Restraining and Bracing of Metal Plate Connected Wood Trusses” for additional information. Job 1802242-12T Truss T04 TrussType Common Qty 1 Ply 1 1802242-12TDWHWoodside-West Clay- 4 Job Reference (optional)Run:8.200 s Apr72018 Print:8.200 s Apr72018MiTekIndustries,Inc.Tue Jun1221:11:472018 Page1ID:bRTO9oDnRLEHvJjVgeMKW3yF_s1-YCkG0NAtcnJOwSv12UdlgbQXRpLpgLdgZNIbW9z6wGg Scale=1:57.9 T2 T3 B1 W2 W1 W2 W1 HW2 T1 B21 2 3 4 5 6 7 10 9 8 17 18 19 20 21 22 3x5 3x4 3x4 4x6 1.5x4 3x4 1.5x4 3x8 3x4 7-8-15 7-8-15 15-3-1 7-6-2 22-10-0 7-6-15 -1-4-12 1-4-12 5-10-7 5-10-7 11-6-0 5-7-9 17-1-9 5-7-9 22-10-0 5-8-7 0 -5 -12 9 -1 -4 0 -7 -4 9.0012 PlateOffsets(X,Y)-- [2:0-0-0,0-0-3], [7:0-0-5,0-0-7], [7:0-0-10,0-3-15], [7:0-3-8,Edge] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 10.0 SPACING- PlateGrip DOL Lumber DOL RepStressIncr Code 2-0-0 1.15 1.15 YES IBC2012/TPI2007 CSI. TC BC WB Matrix-MSH 0.35 0.48 0.83 DEFL. Vert(LL) Vert(TL) Horz(TL) in 0.14 -0.19 0.03 (loc) 10-13 10-13 7 l/defl >999 >999 n/a L/d 240 180 n/a PLATES MT20 Weight: 93 lb FT= 20% GRIP 197/144 LUMBER- TOP CHORD2x4SPF No.2BOT CHORD2x4SPF No.2 WEBS 2x4SPF No.2 *Except* W1: 2x4SPFStudWEDGE Right: 2x4SPFStud BRACING- TOP CHORD Structuralwoodsheathing directly applied or 5-2-4 oc purlins.BOT CHORD Rigidceiling directly applied or 7-5-9 oc bracing. MiTekrecommends that Stabilizers and requiredcross bracing beinstalled during truss erection,in accordancewithStabilizer Installation guide. REACTIONS.(lb/size)2=882/0-4-0(min. 0-1-9), 7=806/0-6-0(min. 0-1-8) Max Horz2=243(LC 13) Max Uplift2=-146(LC 16), 7=-111(LC 17)MaxGrav2=1000(LC 2), 7=910(LC 2) FORCES.(lb)-Max. Comp./Max.Ten.-All forces 250 (lb) orless exceptwhenshown. TOP CHORD 2-17=-1219/767, 3-17=-1128/798, 3-4=-1090/850, 4-18=-993/866, 18-19=-978/870, 5-19=-970/887, 5-20=-968/892, 20-21=-970/873, 6-21=-1079/855, 6-22=-1029/802, 7-22=-1197/779 BOT CHORD 2-10=-564/903, 9-10=-276/595, 8-9=-276/595, 7-8=-555/891 WEBS 5-8=-500/472, 6-8=-349/264, 5-10=-515/492, 3-10=-365/266 NOTES- 1) Unbalancedroofliveloads have been considered for this design. 2)Wind:ASCE 7-10;Vult=115mph(3-second gust)Vasd=91mph;TCDL=6.0psf;BCDL=6.0psf; h=25ft; Cat. II;Exp C; enclosed; MWFRS(envelope) gable end zone and C-CExterior(2)-1-4-12 to 1-7-4,Interior(1) 1-7-4 to 11-6-0,Exterior(2) 11-6-0 to 14-6-0 zone;cantileverleft and right exposed ; end verticalleft and right exposed; porchleft and right exposed;C-C formembers and forces &MWFRS forreactionsshown; Lumber DOL=1.60 plate grip DOL=1.60 3)TCLL:ASCE 7-10;Pr=20.0 psf(roofliveload: Lumber DOL=1.15Plate DOL=1.15);Pg=20.0 psf(groundsnow);Pf=15.4 psf(flatroofsnow: Lumber DOL=1.15Plate DOL=1.15); CategoryII;Exp C; PartiallyExp.; Ct=1.1 4) Unbalancedsnowloads have been considered for this design. 5)This truss has been designed for greater of minroofliveload of 12.0 psf or 2.00 times flatroofload of 15.4 psf on overhangsnon-concurrentwith otherliveloads. 6)This truss has been designed for a 10.0 psf bottomchordliveload nonconcurrentwith any otherliveloads. 7)Providemechanicalconnection(by others) of truss to bearing platecapable of withstanding 100 lb uplift at joint(s) except(jt=lb)2=146, 7=111. 8)This trussis designedin accordancewith the 2012 InternationalBuilding Code section 2306.1 and referencedstandardANSI/TPI 1. LOADCASE(S)Standard DE Job # 59223-W1 Dansco Engineering, LLC Date: 6/13/18 WARNING – VERIFY DESIGN PARAMETERS AND READ NOTES BEFORE FABRICATION AND INSTALLATION!!! This truss design is adequate for the design parameters shown. Review and approval of design parameters is the responsibility of the building designer, not the truss designer or truss engineer. Permanent bracing requirements against out-of-plane buckling are noted/shown for individual truss members (and for the truss as a whole) subjected to gravity and wind loads. Additional permanent bracing design shall be the responsibility of the design professional of record. Temporary and erection bracing shall be the responsibility of the contractor. Reference ANSI/TPI-1, “National Design Standard for Metal Plate Connected Wood Truss Construction” and TPI/WTCA BCSI-06, “Building Component Safety Information Guide to Good Practice for Handling, Installing, Restraining and Bracing of Metal Plate Connected Wood Trusses” for additional information. Job 1802242-12T Truss T05 TrussType Common Qty 1 Ply 1 1802242-12TDWHWoodside-West Clay- 4 Job Reference (optional)Run:8.200 s Apr72018 Print:8.200 s Apr72018MiTekIndustries,Inc.Tue Jun1221:11:482018 Page1ID:bRTO9oDnRLEHvJjVgeMKW3yF_s1-1OIeDjAVN5SFXbUDcC8_Dpyi1DhyPnkqn1182cz6wGf Scale=1:54.0 T1 T2 B1 W2 W1 W2 W1 HW2B2 1 2 3 4 5 8 7 6 15 16 17 18 19 20 3x5 3x4 4x6 3x4 1.5x4 3x4 1.5x4 3x8 7-8-15 7-8-15 15-3-1 7-6-2 22-10-0 7-6-15 5-10-7 5-10-7 11-6-0 5-7-9 17-1-9 5-7-9 22-10-0 5-8-7 0 -5 -12 9 -1 -4 0 -7 -4 9.0012 PlateOffsets(X,Y)-- [1:0-0-0,0-0-3], [5:0-0-5,0-0-7], [5:0-0-10,0-3-15], [5:0-3-8,Edge] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 10.0 SPACING- PlateGrip DOL Lumber DOL RepStressIncr Code 2-0-0 1.15 1.15 YES IBC2012/TPI2007 CSI. TC BC WB Matrix-MSH 0.36 0.49 0.84 DEFL. Vert(LL) Vert(TL) Horz(TL) in 0.15 -0.20 0.03 (loc) 8-11 8-11 5 l/defl >999 >999 n/a L/d 240 180 n/a PLATES MT20 Weight: 91 lb FT= 20% GRIP 197/144 LUMBER- TOP CHORD2x4SPF No.2BOT CHORD2x4SPF No.2 WEBS 2x4SPF No.2 *Except* W1: 2x4SPFStudWEDGE Right: 2x4SPFStud BRACING- TOP CHORD Structuralwoodsheathing directly applied or 4-11-14 oc purlins.BOT CHORD Rigidceiling directly applied or 7-4-14 oc bracing. MiTekrecommends that Stabilizers and requiredcross bracing beinstalled during truss erection,in accordancewithStabilizer Installation guide. REACTIONS.(lb/size)1=809/0-4-0(min. 0-1-8), 5=808/0-6-0(min. 0-1-8) Max Horz1=225(LC 13) Max Uplift1=-113(LC 16), 5=-111(LC 17)MaxGrav1=914(LC 2), 5=913(LC 2) FORCES.(lb)-Max. Comp./Max.Ten.-All forces 250 (lb) orless exceptwhenshown. TOP CHORD 1-15=-1228/788, 2-15=-1129/813, 2-16=-1101/868, 16-17=-988/887, 3-17=-980/905, 3-18=-963/893, 18-19=-971/875, 4-19=-1083/858, 4-20=-1032/804, 5-20=-1200/780 BOT CHORD 1-8=-569/913, 7-8=-278/598, 6-7=-278/598, 5-6=-556/893 WEBS 3-6=-499/471, 4-6=-349/265, 3-8=-521/500, 2-8=-364/270 NOTES- 1) Unbalancedroofliveloads have been considered for this design. 2)Wind:ASCE 7-10;Vult=115mph(3-second gust)Vasd=91mph;TCDL=6.0psf;BCDL=6.0psf; h=25ft; Cat. II;Exp C; enclosed; MWFRS(envelope) gable end zone and C-CExterior(2) 0-0-0 to 3-0-0,Interior(1) 3-0-0 to 11-6-0,Exterior(2) 11-6-0 to 14-6-0zone; cantileverleft and right exposed ; end verticalleft and right exposed; porchleft and right exposed;C-C formembers and forces & MWFRS forreactionsshown; Lumber DOL=1.60 plate grip DOL=1.60 3)TCLL:ASCE 7-10;Pr=20.0 psf(roofliveload: Lumber DOL=1.15Plate DOL=1.15);Pg=20.0 psf(groundsnow);Pf=15.4 psf(flat roofsnow: Lumber DOL=1.15Plate DOL=1.15); CategoryII;Exp C; PartiallyExp.; Ct=1.14) Unbalancedsnowloads have been considered for this design. 5)This truss has been designed for a 10.0 psf bottomchordliveload nonconcurrentwith any otherliveloads. 6)Providemechanicalconnection(by others) of truss to bearing platecapable of withstanding 100 lb uplift at joint(s) except(jt=lb)1=113, 5=111. 7)This trussis designedin accordancewith the 2012 InternationalBuilding Code section 2306.1 and referencedstandardANSI/TPI 1. LOADCASE(S)Standard DE Job # 59223-W1 Dansco Engineering, LLC Date: 6/13/18 WARNING – VERIFY DESIGN PARAMETERS AND READ NOTES BEFORE FABRICATION AND INSTALLATION!!! This truss design is adequate for the design parameters shown. Review and approval of design parameters is the responsibility of the building designer, not the truss designer or truss engineer. Permanent bracing requirements against out-of-plane buckling are noted/shown for individual truss members (and for the truss as a whole) subjected to gravity and wind loads. Additional permanent bracing design shall be the responsibility of the design professional of record. Temporary and erection bracing shall be the responsibility of the contractor. Reference ANSI/TPI-1, “National Design Standard for Metal Plate Connected Wood Truss Construction” and TPI/WTCA BCSI-06, “Building Component Safety Information Guide to Good Practice for Handling, Installing, Restraining and Bracing of Metal Plate Connected Wood Trusses” for additional information. Job 1802242-12T Truss T06 TrussType Roof SpecialGirder Qty 1 Ply 1 1802242-12TDWHWoodside-West Clay- 4 Job Reference (optional)Run:8.200 s Apr72018 Print:8.200 s Apr72018MiTekIndustries,Inc.Tue Jun1221:11:492018 Page1ID:bRTO9oDnRLEHvJjVgeMKW3yF_s1-Vbs1R3B78Pa69l2Q9vfDl0VwRd2R8MNz0hnia2z6wGe Scale=1:35.5 W1 T1 B1 W2 W3 1 2 3 5 4 9 10 11 1.5x4 3x44x4 3x6 3x10 3-3-0 3-3-0 6-6-0 3-3-0 3-3-0 3-3-0 6-6-0 3-3-0 5 -5 -12 0 -7 -4 9.0012 LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 10.0 SPACING- PlateGrip DOL Lumber DOL RepStressIncr Code 2-0-0 1.15 1.15 NO IBC2012/TPI2007 CSI. TC BC WB Matrix-MP 0.13 0.41 0.36 DEFL. Vert(LL) Vert(TL) Horz(TL) in -0.01 -0.03 0.00 (loc) 4-5 4-5 3 l/defl >999 >999 n/a L/d 240 180 n/a PLATES MT20 Weight: 33 lb FT= 20% GRIP 197/144 LUMBER- TOP CHORD2x4SPF No.2 BOT CHORD2x6SPF No.2WEBS2x4SPFStud BRACING- TOP CHORD Structuralwoodsheathing directly applied or 6-0-0 oc purlins, except end verticals.BOT CHORD Rigidceiling directly applied or 10-0-0 oc bracing. MiTekrecommends that Stabilizers and requiredcross bracing beinstalled during truss erection,in accordancewithStabilizer Installation guide.REACTIONS.(lb/size)3=810/0-6-0(min. 0-1-8), 5=767/0-6-0(min. 0-1-8) Max Horz5=-194(LC 13) Max Uplift3=-38(LC 8), 5=-182(LC 13)MaxGrav3=909(LC 2), 5=860(LC 2) FORCES.(lb)-Max. Comp./Max.Ten.-All forces 250 (lb) orless exceptwhenshown.TOP CHORD 2-3=-866/28 BOT CHORD 5-10=-9/669, 4-10=-9/669, 4-11=-9/669, 3-11=-9/669 WEBS 2-5=-876/189, 2-4=-66/847 NOTES- 1)Wind:ASCE 7-10;Vult=115mph(3-second gust)Vasd=91mph;TCDL=6.0psf;BCDL=6.0psf; h=25ft; Cat. II;Exp C; enclosed; MWFRS(envelope) gable end zone;cantileverright exposed ; end verticalright exposed; porchleft and right exposed; Lumber DOL=1.60 plate grip DOL=1.60 2)TCLL:ASCE 7-10;Pr=20.0 psf(roofliveload: Lumber DOL=1.15Plate DOL=1.15);Pg=20.0 psf(groundsnow);Pf=15.4 psf(flat roofsnow: Lumber DOL=1.15Plate DOL=1.15); CategoryII;Exp C; PartiallyExp.; Ct=1.1 3) Unbalancedsnowloads have been considered for this design. 4)This truss has been designed for a 10.0 psf bottomchordliveload nonconcurrentwith any otherliveloads. 5)Providemechanicalconnection(by others) of truss to bearing platecapable of withstanding 100 lb uplift at joint(s) 3 except(jt=lb) 5=182. 6)This trussis designedin accordancewith the 2012 InternationalBuilding Code section 2306.1 and referencedstandardANSI/TPI 1. 7) Hanger(s) or otherconnection device(s)shall be providedsufficient to supportconcentratedload(s) 420 lb down and 42 lb up at 1-6-8, and 420 lb down and 42 lb up at 3-6-8, and 420 lb down and 42 lb up at 5-6-8 on bottomchord.The design/selection of suchconnection device(s)is the responsibility of others. 8)In the LOAD CASE(S)section,loads applied to the face of the truss are noted as front(F) or back(B). LOADCASE(S)Standard 1) Dead +Snow(balanced): LumberIncrease=1.15,PlateIncrease=1.15Uniform Loads(plf) Vert: 1-3=-51, 5-6=-20 Concentrated Loads(lb)Vert: 4=-376(B) 10=-376(B) 11=-376(B) DE Job # 59223-W1 Dansco Engineering, LLC Date: 6/13/18 WARNING – VERIFY DESIGN PARAMETERS AND READ NOTES BEFORE FABRICATION AND INSTALLATION!!! This truss design is adequate for the design parameters shown. Review and approval of design parameters is the responsibility of the building designer, not the truss designer or truss engineer. Permanent bracing requirements against out-of-plane buckling are noted/shown for individual truss members (and for the truss as a whole) subjected to gravity and wind loads. Additional permanent bracing design shall be the responsibility of the design professional of record. Temporary and erection bracing shall be the responsibility of the contractor. Reference ANSI/TPI-1, “National Design Standard for Metal Plate Connected Wood Truss Construction” and TPI/WTCA BCSI-06, “Building Component Safety Information Guide to Good Practice for Handling, Installing, Restraining and Bracing of Metal Plate Connected Wood Trusses” for additional information. Job 1802242-12T Truss T07 TrussType Jack-ClosedGirder Qty 1 Ply 1 1802242-12TDWHWoodside-West Clay- 4 Job Reference (optional)Run:8.200 s Apr72018 Print:8.200 s Apr72018MiTekIndustries,Inc.Tue Jun1221:11:512018 Page1ID:bRTO9oDnRLEHvJjVgeMKW3yF_s1-RzznskDNg0qpO3CoHKhhqRaEEQjFcEbGT?Gofxz6wGc Scale=1:37.9 0 -1 -14 T1 T2 W10 B1 B3 B4W1W2 W3 W4 W5 W6 W5 W8 W7 W9 B2 1 2 3 4 5 6 7 16 15 14 13 12 11 10 9 8 20 2122 23 24 25 26 27 28 29 30 31 4x4 6x6 3x6 3x4 2x4 1.5x4 6x8 3x4 1.5x4 3x4 1.5x4 3x8 3x5 3x8 4x4 3-11-0 3-11-0 7-5-2 3-6-2 11-7-7 4-2-5 15-9-11 4-2-5 20-0-0 4-2-5 21-0-0 1-0-0 3-11-0 3-11-0 7-5-2 3-6-2 11-7-7 4-2-5 15-9-11 4-2-5 20-0-0 4-2-5 21-0-0 1-0-0 0 -5 -0 3 -11 -11 4 -1 -9 2 -11 -11 1 -0 -0 6.0012 PlateOffsets(X,Y)-- [1:0-0-3,0-0-13], [9:0-2-0,0-3-0] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 10.0 SPACING- PlateGrip DOL Lumber DOL RepStressIncr Code 2-0-0 1.15 1.15 NO IBC2012/TPI2007 CSI. TC BC WB Matrix-MSH 0.30 0.45 0.45 DEFL. Vert(LL) Vert(TL) Horz(TL) in 0.09 -0.13 0.03 (loc) 13-14 13-14 8 l/defl >999 >999 n/a L/d 240 180 n/a PLATES MT20 Weight: 98 lb FT= 20% GRIP 197/144 LUMBER- TOP CHORD2x4SPF No.2BOT CHORD2x4SPF No.2 *Except* B3: 2x4SPFStud WEBS 2x4SPFStud BRACING- TOP CHORD Structuralwoodsheathing directly applied or 4-6-4 oc purlins,except end verticals. BOT CHORD Rigidceiling directly applied or 6-2-13 oc bracing.Except: 10-0-0 oc bracing: 9-11 MiTekrecommends that Stabilizers and requiredcross bracingbeinstalled during truss erection,in accordancewithStabilizer Installation guide. REACTIONS.(lb/size)1=798/Mechanical, 8=858/0-6-0(min. 0-1-13)Max Horz1=133(LC 9) Max Uplift1=-470(LC 12), 8=-636(LC 9) MaxGrav1=928(LC 67), 8=1137(LC 72) FORCES.(lb)-Max. Comp./Max.Ten.-All forces 250 (lb) orless exceptwhenshown. TOP CHORD 1-20=-1642/910, 2-20=-1571/927, 2-3=-1497/920, 3-21=-1582/935, 21-22=-1583/935,4-22=-1585/935, 4-23=-1582/933, 23-24=-1582/933, 5-24=-1582/933, 5-25=-435/259, 25-26=-435/259, 6-26=-435/259, 6-7=-418/248, 7-8=-1006/561 BOT CHORD 1-16=-895/1434, 15-16=-895/1434, 14-15=-895/1434, 14-27=-882/1327, 13-27=-882/1327, 13-28=-727/1196, 28-29=-727/1196, 12-29=-727/1196, 6-9=-252/174 WEBS 2-14=-361/136, 3-14=-114/304, 3-13=-149/350, 4-13=-411/265, 5-13=-321/477, 9-12=-673/1090, 5-9=-958/560, 7-9=-618/1069 NOTES- 1) Unbalancedroofliveloads have been considered for this design. 2)Wind:ASCE 7-10;Vult=115mph(3-second gust)Vasd=91mph;TCDL=6.0psf;BCDL=6.0psf; h=25ft; Cat. II;Exp C; enclosed; MWFRS(envelope) gable end zone;cantileverleft and right exposed ; end verticalleft and right exposed; Lumber DOL=1.60 plate grip DOL=1.60 3)TCLL:ASCE 7-10;Pr=20.0 psf(roofliveload: Lumber DOL=1.15Plate DOL=1.15);Pg=20.0 psf(groundsnow);Pf=20.4 psf(flat roofsnow: Lumber DOL=1.15Plate DOL=1.15); CategoryII;Exp C; PartiallyExp.; Ct=1.1, Lu=50-0-0;Min. flatroofsnowload governs. Rainsurcharge applied to all exposedsurfaceswithslopesless than 0.500/12 in accordancewithIBC 1608.3.4. 4) Unbalancedsnowloads have been considered for this design.5)Provide adequate drainage to preventwater ponding. 6)This truss has been designed for a 10.0 psf bottomchordliveload nonconcurrentwith any otherliveloads. 7) Refer to girder(s) for truss to trussconnections.8)Providemechanicalconnection(by others) of truss to bearing platecapable of withstanding 100 lb uplift at joint(s) except(jt=lb) 1=470, 8=636. 9)This trussis designedin accordancewith the 2012 InternationalBuilding Code section 2306.1 and referencedstandardANSI/TPI 1. Continued on page 2 DE Job # 59223-W1 Dansco Engineering, LLC Date: 6/13/18 WARNING – VERIFY DESIGN PARAMETERS AND READ NOTES BEFORE FABRICATION AND INSTALLATION!!! This truss design is adequate for the design parameters shown. Review and approval of design parameters is the responsibility of the building designer, not the truss designer or truss engineer. Permanent bracing requirements against out-of-plane buckling are noted/shown for individual truss members (and for the truss as a whole) subjected to gravity and wind loads. Additional permanent bracing design shall be the responsibility of the design professional of record. Temporary and erection bracing shall be the responsibility of the contractor. Reference ANSI/TPI-1, “National Design Standard for Metal Plate Connected Wood Truss Construction” and TPI/WTCA BCSI-06, “Building Component Safety Information Guide to Good Practice for Handling, Installing, Restraining and Bracing of Metal Plate Connected Wood Trusses” for additional information. Job 1802242-12T Truss T07 TrussType Jack-ClosedGirder Qty 1 Ply 1 1802242-12TDWHWoodside-West Clay- 4 Job Reference (optional)Run:8.200 s Apr72018 Print:8.200 s Apr72018MiTekIndustries,Inc.Tue Jun1221:11:512018 Page2ID:bRTO9oDnRLEHvJjVgeMKW3yF_s1-RzznskDNg0qpO3CoHKhhqRaEEQjFcEbGT?Gofxz6wGc NOTES- 10) Hanger(s) or otherconnection device(s)shall be providedsufficient to supportconcentratedload(s) 62 lb down and 105 lb up at 3-11-10, 175 lb down and 198 lb up at 7-5-2, 95 lb down and 86 lb up at 9-5-14, 95 lb down and 86 lb up at 11-5-14, 95 lb down and 86 lb up at 13-5-14, 95 lb down and 86 lb up at 15-5-14, and 95 lb down and 86 lb up at 17-5-14, and 95 lb down and 86 lb up at 19-5-14 on top chord, and 27 lb down at 3-11-10, 82 lb down and 95 lb up at 7-5-2, 41 lb down and 38 lb up at 9-5-14, 41 lb down and 38 lb up at 11-5-14, 41 lb down and 38 lb up at 13-5-14, 41 lb down and 38 lb up at 15-5-14, and 41 lb down and 38 lb up at 17-5-14, and 41 lb down and 38 lb up at 19-5-14 on bottomchord.The design/selection of suchconnection device(s)is the responsibility of others. 11)In the LOAD CASE(S)section,loads applied to the face of the truss are noted as front(F) or back(B). LOADCASE(S)Standard 1) Dead +Snow(balanced): LumberIncrease=1.15,PlateIncrease=1.15 Uniform Loads(plf) Vert: 1-3=-51, 3-7=-61, 11-17=-20, 10-11=-20, 8-9=-20 Concentrated Loads(lb)Vert: 3=-0(F) 16=-6(F) 14=-3(F) 4=-0(F) 13=-4(F) 21=-0(F) 23=-0(F) 24=-0(F) 25=-0(F) 26=-0(F) 27=-4(F) 28=-4(F) 29=-4(F) 30=-4(F) 31=-4(F) DE Job # 59223-W1 Dansco Engineering, LLC Date: 6/13/18 WARNING – VERIFY DESIGN PARAMETERS AND READ NOTES BEFORE FABRICATION AND INSTALLATION!!! This truss design is adequate for the design parameters shown. Review and approval of design parameters is the responsibility of the building designer, not the truss designer or truss engineer. Permanent bracing requirements against out-of-plane buckling are noted/shown for individual truss members (and for the truss as a whole) subjected to gravity and wind loads. Additional permanent bracing design shall be the responsibility of the design professional of record. Temporary and erection bracing shall be the responsibility of the contractor. Reference ANSI/TPI-1, “National Design Standard for Metal Plate Connected Wood Truss Construction” and TPI/WTCA BCSI-06, “Building Component Safety Information Guide to Good Practice for Handling, Installing, Restraining and Bracing of Metal Plate Connected Wood Trusses” for additional information. Job 1802242-12T Truss T08 TrussType Jack-Closed Qty 1 Ply 1 1802242-12TDWHWoodside-West Clay- 4 Job Reference (optional)Run:8.200 s Apr72018 Print:8.200 s Apr72018MiTekIndustries,Inc.Tue Jun1221:11:522018 Page1ID:bRTO9oDnRLEHvJjVgeMKW3yF_s1-vAX934E0RKyg0Dn?r2DwNf7Nbq38Lf5Pif?MBNz6wGb Scale=1:41.8 0 -1 -14 T1 T2 W9 B1 B3 B4W1W2 W3 W4 W5 W7 W6 W8 B2 1 2 3 4 5 6 14 13 12 11 10 9 8 7 18 19 20 2122 23 3x4 6x6 3x5 1.5x4 3x4 2x4 1.5x4 6x8 3x4 1.5x4 3x4 3x4 3x8 5-5-0 5-5-0 10-5-2 5-0-2 15-2-9 4-9-7 20-0-0 4-9-7 21-0-0 1-0-0 5-5-0 5-5-0 10-5-2 5-0-2 15-2-9 4-9-7 20-0-0 4-9-7 21-0-0 1-0-0 0 -5 -0 5 -5 -11 5 -7 -9 4 -5 -11 1 -0 -0 5 -5 -11 6.0012 PlateOffsets(X,Y)-- [8:0-2-12,0-2-12] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 10.0 SPACING- PlateGrip DOL Lumber DOL RepStressIncr Code 2-0-0 1.15 1.15 YES IBC2012/TPI2007 CSI. TC BC WB Matrix-MSH 0.39 0.41 0.56 DEFL. Vert(LL) Vert(TL) Horz(TL) in -0.04 -0.11 0.03 (loc) 14 12-14 7 l/defl >999 >999 n/a L/d 240 180 n/a PLATES MT20 Weight: 104 lb FT= 20% GRIP 197/144 LUMBER- TOP CHORD2x4SPF No.2BOT CHORD2x4SPF No.2 *Except* B3: 2x4SPFStud WEBS 2x4SPFStud BRACING- TOP CHORD Structuralwoodsheathing directly applied or 4-4-1 oc purlins,except end verticals. BOT CHORD Rigidceiling directly applied or 9-7-6 oc bracing.Except: 10-0-0 oc bracing: 8-10 MiTekrecommends that Stabilizers and requiredcross bracingbeinstalled during truss erection,in accordancewithStabilizer Installation guide. REACTIONS.(lb/size)1=768/Mechanical, 7=826/0-6-0(min. 0-1-9)Max Horz1=195(LC 13) Max Uplift1=-116(LC 16), 7=-152(LC 13) MaxGrav1=973(LC 35), 7=979(LC 34) FORCES.(lb)-Max. Comp./Max.Ten.-All forces 250 (lb) orless exceptwhenshown. TOP CHORD 1-18=-1617/211, 2-18=-1516/226, 2-19=-1035/188, 19-20=-1006/189, 3-20=-946/212,3-21=-768/198, 21-22=-770/197, 4-22=-771/197, 6-7=-846/144 BOT CHORD 1-14=-377/1366, 13-14=-377/1366, 12-13=-377/1366, 11-12=-259/842, 5-8=-280/119 WEBS 2-12=-614/173, 3-12=-27/408, 3-11=-350/102, 4-11=-0/255, 8-11=-185/665, 4-8=-728/139, 6-8=-175/881 NOTES- 1) Unbalancedroofliveloads have been considered for this design. 2)Wind:ASCE 7-10;Vult=115mph(3-second gust)Vasd=91mph;TCDL=6.0psf;BCDL=6.0psf; h=25ft; Cat. II;Exp C; enclosed; MWFRS(envelope) gable end zone and C-CExterior(2) 0-0-0 to 3-0-0,Interior(1) 3-0-0 to 10-5-2,Exterior(2) 10-5-2 to 14-8-1zone; cantileverleft and right exposed ; end verticalleft and right exposed;C-C formembers and forces&MWFRS forreactionsshown; Lumber DOL=1.60 plate grip DOL=1.60 3)TCLL:ASCE 7-10;Pr=20.0 psf(roofliveload: Lumber DOL=1.15Plate DOL=1.15);Pg=20.0 psf(groundsnow);Pf=20.4 psf(flat roofsnow: Lumber DOL=1.15Plate DOL=1.15); CategoryII;Exp C; PartiallyExp.; Ct=1.1, Lu=50-0-0;Min. flatroofsnowload governs. Rainsurcharge applied to all exposedsurfaceswithslopesless than 0.500/12 in accordancewithIBC 1608.3.4. 4) Unbalancedsnowloads have been considered for this design. 5)Provide adequate drainage to preventwater ponding.6)This truss has been designed for a 10.0 psf bottomchordliveload nonconcurrentwith any otherliveloads. 7) Refer to girder(s) for truss to trussconnections. 8)Providemechanicalconnection(by others) of truss to bearing platecapable of withstanding 100 lb uplift at joint(s) except(jt=lb)1=116, 7=152. 9)This trussis designedin accordancewith the 2012 InternationalBuilding Code section 2306.1 and referencedstandardANSI/TPI 1. LOADCASE(S)Standard DE Job # 59223-W1 Dansco Engineering, LLC Date: 6/13/18 WARNING – VERIFY DESIGN PARAMETERS AND READ NOTES BEFORE FABRICATION AND INSTALLATION!!! This truss design is adequate for the design parameters shown. Review and approval of design parameters is the responsibility of the building designer, not the truss designer or truss engineer. Permanent bracing requirements against out-of-plane buckling are noted/shown for individual truss members (and for the truss as a whole) subjected to gravity and wind loads. Additional permanent bracing design shall be the responsibility of the design professional of record. Temporary and erection bracing shall be the responsibility of the contractor. Reference ANSI/TPI-1, “National Design Standard for Metal Plate Connected Wood Truss Construction” and TPI/WTCA BCSI-06, “Building Component Safety Information Guide to Good Practice for Handling, Installing, Restraining and Bracing of Metal Plate Connected Wood Trusses” for additional information. Job 1802242-12T Truss T09 TrussType Jack-Closed Qty 1 Ply 1 1802242-12TDWHWoodside-West Clay- 4 Job Reference (optional)Run:8.200 s Apr72018 Print:8.200 s Apr72018MiTekIndustries,Inc.Tue Jun1221:11:532018 Page1ID:bRTO9oDnRLEHvJjVgeMKW3yF_s1-NM5XHQEeCd4XeNMBOlk9wsgU1EO5416ZxJlvjpz6wGa Scale:1/4"=1' 0 -1 -14 T1 T2 W7 B1 B3 B4W1W2 W3 W5 W4 W6 B2 1 2 3 4 5 12 11 10 9 8 7 6 16 17 18 19 2021 3x5 6x6 4x4 2x4 3x4 3x5 3x4 5x12 3x4 1.5x4 4x8 6-11-0 6-11-0 13-5-2 6-6-2 20-0-0 6-6-14 21-0-0 1-0-0 6-11-0 6-11-0 13-5-2 6-6-2 20-0-0 6-6-14 21-0-0 1-0-0 0 -5 -0 6 -11 -11 7 -1 -9 5 -11 -11 1 -0 -0 6 -11 -11 6.0012 PlateOffsets(X,Y)-- [7:0-4-8,0-2-0] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 10.0 SPACING- PlateGrip DOL Lumber DOL RepStressIncr Code 2-0-0 1.15 1.15 YES IBC2012/TPI2007 CSI. TC BC WB Matrix-MSH 0.67 0.49 0.89 DEFL. Vert(LL) Vert(TL) Horz(TL) in -0.06 -0.16 0.04 (loc) 12-15 12-15 6 l/defl >999 >999 n/a L/d 240 180 n/a PLATES MT20 Weight: 106 lb FT= 20% GRIP 197/144 LUMBER- TOP CHORD2x4SPF No.2BOT CHORD2x4SPF No.2 *Except* B3: 2x4SPFStud WEBS 2x4SPFStud*Except*W4: 2x4SPF No.2 BRACING- TOP CHORD Structuralwoodsheathing directly applied or 4-1-4 oc purlins,except end verticals. BOT CHORD Rigidceiling directly applied or 9-7-8 oc bracing.Except: 10-0-0 oc bracing: 7-9WEBS1 Row at midpt 3-7 MiTekrecommends that Stabilizers and requiredcross bracing beinstalled during truss erection,in accordancewithStabilizer Installation guide.REACTIONS.(lb/size)1=757/Mechanical, 6=807/0-6-0(min. 0-1-8) Max Horz1=258(LC 13) Max Uplift1=-130(LC 16), 6=-143(LC 13)MaxGrav1=992(LC 35), 6=878(LC 34) FORCES.(lb)-Max. Comp./Max.Ten.-All forces 250 (lb) orless exceptwhenshown.TOP CHORD 1-16=-1651/174, 16-17=-1570/185, 2-17=-1443/206, 2-18=-898/155, 18-19=-756/171, 3-19=-743/186, 5-6=-721/164 BOT CHORD 1-12=-370/1391, 11-12=-370/1391, 10-11=-370/1391, 4-7=-615/231 WEBS 2-12=0/260, 2-10=-821/230, 3-10=-20/460, 7-10=-228/510, 3-7=-711/168, 5-7=-226/947 NOTES- 1) Unbalancedroofliveloads have been considered for this design. 2)Wind:ASCE 7-10;Vult=115mph(3-second gust)Vasd=91mph;TCDL=6.0psf;BCDL=6.0psf; h=25ft; Cat. II;Exp C; enclosed; MWFRS(envelope) gable end zone and C-CExterior(2) 0-0-0 to 3-0-0,Interior(1) 3-0-0 to 13-5-2,Exterior(2) 13-5-2 to 17-8-1zone; cantileverleft and right exposed ; end verticalleft and right exposed;C-C formembers and forces&MWFRS forreactionsshown; Lumber DOL=1.60 plate grip DOL=1.60 3)TCLL:ASCE 7-10;Pr=20.0 psf(roofliveload: Lumber DOL=1.15Plate DOL=1.15);Pg=20.0 psf(groundsnow);Pf=20.4 psf(flat roofsnow: Lumber DOL=1.15Plate DOL=1.15); CategoryII;Exp C; PartiallyExp.; Ct=1.1, Lu=50-0-0;Min. flatroofsnowloadgoverns. Rainsurcharge applied to all exposedsurfaceswithslopesless than 0.500/12 in accordancewithIBC 1608.3.4. 4) Unbalancedsnowloads have been considered for this design. 5)Provide adequate drainage to preventwater ponding.6)This truss has been designed for a 10.0 psf bottomchordliveload nonconcurrentwith any otherliveloads. 7) Refer to girder(s) for truss to trussconnections. 8)Providemechanicalconnection(by others) of truss to bearing platecapable of withstanding 100 lb uplift at joint(s) except(jt=lb)1=130, 6=143. 9)This trussis designedin accordancewith the 2012 InternationalBuilding Code section 2306.1 and referencedstandardANSI/TPI 1. LOADCASE(S)Standard DE Job # 59223-W1 Dansco Engineering, LLC Date: 6/13/18 WARNING – VERIFY DESIGN PARAMETERS AND READ NOTES BEFORE FABRICATION AND INSTALLATION!!! This truss design is adequate for the design parameters shown. Review and approval of design parameters is the responsibility of the building designer, not the truss designer or truss engineer. Permanent bracing requirements against out-of-plane buckling are noted/shown for individual truss members (and for the truss as a whole) subjected to gravity and wind loads. Additional permanent bracing design shall be the responsibility of the design professional of record. Temporary and erection bracing shall be the responsibility of the contractor. Reference ANSI/TPI-1, “National Design Standard for Metal Plate Connected Wood Truss Construction” and TPI/WTCA BCSI-06, “Building Component Safety Information Guide to Good Practice for Handling, Installing, Restraining and Bracing of Metal Plate Connected Wood Trusses” for additional information. Job 1802242-12T Truss T10 TrussType Jack-Closed Qty 1 Ply 1 1802242-12TDWHWoodside-West Clay- 4 Job Reference (optional)Run:8.200 s Apr72018 Print:8.200 s Apr72018MiTekIndustries,Inc.Tue Jun1221:11:542018 Page1ID:bRTO9oDnRLEHvJjVgeMKW3yF_s1-rYfwUmFGyxCOFWxNyTFOS4CaueizpU6iAzUTFFz6wGZ Scale=1:54.7 0 -1 -14 T2 T3 W7 B1 B3 B4W1 W2 W3 W5 W4 W6 T1 B2 1 2 3 4 5 6 13 12 11 10 9 87 17 18 19 20 21 3x4 6x6 3x8 3x4 3x5 3x4 1.5x4 1.5x4 6x8 3x4 1.5x4 3x8 8-5-0 8-5-0 16-5-2 8-0-2 20-0-0 3-6-14 21-0-0 1-0-0 8-5-0 8-5-0 16-5-2 8-0-2 20-0-0 3-6-14 21-0-0 1-0-0 0 -5 -0 8 -5 -11 8 -7 -9 7 -5 -11 1 -0 -0 8 -5 -11 6.0012 PlateOffsets(X,Y)-- [8:0-2-4,0-3-0] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 10.0 SPACING- PlateGrip DOL Lumber DOL RepStressIncr Code 2-0-0 1.15 1.15 YES IBC2012/TPI2007 CSI. TC BC WB Matrix-MSH 0.98 0.58 0.84 DEFL. Vert(LL) Vert(TL) Horz(TL) in 0.09 -0.26 0.04 (loc) 13-16 13-16 7 l/defl >999 >979 n/a L/d 240 180 n/a PLATES MT20 Weight: 112 lb FT= 20% GRIP 197/144 LUMBER- TOP CHORD2x4SPF No.2BOT CHORD2x4SPF No.2 WEBS 2x4SPFStud*Except* W2,W3,W4: 2x4SPF No.2 BRACING- TOP CHORD Structuralwoodsheathing directly applied, except end verticals.BOT CHORD Rigidceiling directly applied or 9-9-13 oc bracing.Except: 10-0-0 oc bracing: 8-10 WEBS 1 Row at midpt 2-11 MiTekrecommends that Stabilizers and requiredcross bracingbeinstalled during truss erection,in accordancewithStabilizer Installation guide. REACTIONS.(lb/size)7=782/0-6-0(min. 0-1-8), 1=752/MechanicalMax Horz1=320(LC 13) Max Uplift7=-130(LC 13), 1=-136(LC 16) MaxGrav7=875(LC 35), 1=950(LC 35) FORCES.(lb)-Max. Comp./Max.Ten.-All forces 250 (lb) orless exceptwhenshown. TOP CHORD 1-17=-1565/168, 17-18=-1478/174, 2-18=-1352/197, 2-3=-673/129, 3-19=-525/144,19-20=-497/148, 4-20=-393/166, 6-7=-752/203 BOT CHORD 1-13=-348/1322, 12-13=-348/1322, 11-12=-348/1322 WEBS 2-13=0/345, 2-11=-998/279, 4-11=-50/503, 8-11=-142/371, 4-8=-787/189, 6-8=-175/667 NOTES- 1) Unbalancedroofliveloads have been considered for this design. 2)Wind:ASCE 7-10;Vult=115mph(3-second gust)Vasd=91mph;TCDL=6.0psf;BCDL=6.0psf; h=25ft; Cat. II;Exp C; enclosed; MWFRS(envelope) gable end zone and C-CExterior(2) 0-0-0 to 3-0-0,Interior(1) 3-0-0 to 16-5-2,Exterior(2) 16-5-2 to 20-10-4 zone;cantileverleft and right exposed ; end verticalleft and right exposed;C-C formembers and forces&MWFRS forreactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3)TCLL:ASCE 7-10;Pr=20.0 psf(roofliveload: Lumber DOL=1.15Plate DOL=1.15);Pg=20.0 psf(groundsnow);Pf=20.4 psf(flat roofsnow: Lumber DOL=1.15Plate DOL=1.15); CategoryII;Exp C; PartiallyExp.; Ct=1.1, Lu=50-0-0;Min. flatroofsnowload governs. Rainsurcharge applied to all exposedsurfaceswithslopesless than 0.500/12 in accordancewithIBC 1608.3.4. 4) Unbalancedsnowloads have been considered for this design. 5)Provide adequate drainage to preventwater ponding. 6)This truss has been designed for a 10.0 psf bottomchordliveload nonconcurrentwith any otherliveloads.7) Refer to girder(s) for truss to trussconnections. 8)Providemechanicalconnection(by others) of truss to bearing platecapable of withstanding 100 lb uplift at joint(s) except(jt=lb) 7=130, 1=136.9)This trussis designedin accordancewith the 2012 InternationalBuilding Code section 2306.1 and referencedstandardANSI/TPI 1. LOADCASE(S)Standard DE Job # 59223-W1 Dansco Engineering, LLC Date: 6/13/18 WARNING – VERIFY DESIGN PARAMETERS AND READ NOTES BEFORE FABRICATION AND INSTALLATION!!! This truss design is adequate for the design parameters shown. Review and approval of design parameters is the responsibility of the building designer, not the truss designer or truss engineer. Permanent bracing requirements against out-of-plane buckling are noted/shown for individual truss members (and for the truss as a whole) subjected to gravity and wind loads. Additional permanent bracing design shall be the responsibility of the design professional of record. Temporary and erection bracing shall be the responsibility of the contractor. Reference ANSI/TPI-1, “National Design Standard for Metal Plate Connected Wood Truss Construction” and TPI/WTCA BCSI-06, “Building Component Safety Information Guide to Good Practice for Handling, Installing, Restraining and Bracing of Metal Plate Connected Wood Trusses” for additional information. Job 1802242-12T Truss T11 TrussType Jack-Closed Qty 1 Ply 1 1802242-12TDWHWoodside-West Clay- 4 Job Reference (optional)Run:8.200 s Apr72018 Print:8.200 s Apr72018MiTekIndustries,Inc.Tue Jun1221:11:552018 Page1ID:bRTO9oDnRLEHvJjVgeMKW3yF_s1-JlDIh6GujFKFtgWaWAmd?Hlr324qY?5rOdE0oiz6wGY Scale=1:72.6 0 -1 -14 T2 T3 W7 B1 B3 B4W1W2 W3 W4 W5 W6 T1 B21 2 3 4 56 7 15 14 13 12 1110 9 8 19 20 21 3x5 4x4 3x8 1.5x43x43x4 4x6 3x4 4x4 3x4 1.5x4 3x4 3x4 3x4 6-8-156-8-15 13-1-06-4-2 19-5-26-4-2 20-0-00-6-14 21-0-0 1-0-0 6-8-15 6-8-15 13-1-0 6-4-2 19-5-2 6-4-2 20-0-0 0-6-14 21-0-0 1-0-0 0 -5 -0 9 -11 -11 10 -1 -9 8 -11 -11 1 -0 -0 9 -11 -11 6.0012 PlateOffsets(X,Y)-- [1:0-1-11,0-1-8] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 10.0 SPACING- PlateGrip DOL Lumber DOL RepStressIncr Code 2-0-0 1.15 1.15 YES IBC2012/TPI2007 CSI. TC BC WB Matrix-MSH 0.63 0.47 0.61 DEFL. Vert(LL) Vert(TL) Horz(TL) in -0.08 -0.20 0.01 (loc) 12-13 12-13 1 l/defl >999 >999 n/a L/d 240 180 n/a PLATES MT20 Weight: 121 lb FT= 20% GRIP 197/144 LUMBER- TOP CHORD2x4SPF No.2BOT CHORD2x4SPF No.2 WEBS 2x4SPF No.2 *Except* W1,W2,W3: 2x4SPFStud BRACING- TOP CHORD Structuralwoodsheathing directly applied or 4-5-12 oc purlins,except end verticals. BOT CHORD Rigidceiling directly applied or 9-3-2 oc bracing.Except: 1 Row at midpt 6-910-0-0 oc bracing: 9-11 WEBS 1 Row at midpt 7-8, 4-12 MiTekrecommends that Stabilizers and requiredcross bracing beinstalled during truss erection,in accordancewithStabilizerInstallation guide. REACTIONS.(lb/size)8=759/0-6-0(min. 0-1-9), 1=744/Mechanical Max Horz1=392(LC 16)Max Uplift8=-233(LC 16), 1=-84(LC 16) MaxGrav8=996(LC 35), 1=894(LC 35) FORCES.(lb)-Max. Comp./Max.Ten.-All forces 250 (lb) orless exceptwhenshown. TOP CHORD 1-19=-1537/77, 2-19=-1407/97, 2-20=-1016/19, 3-20=-952/20, 3-4=-807/49, 4-21=-309/0, 7-8=-922/220 BOT CHORD 1-15=-393/1316, 14-15=-393/1316, 13-14=-393/1316, 12-13=-219/819, 9-11=-160/473, 6-9=-691/140 WEBS 2-15=0/257, 2-13=-567/198, 4-13=-24/479, 4-12=-979/269, 5-12=0/356, 7-9=-277/1117 NOTES- 1) Unbalancedroofliveloads have been considered for this design. 2)Wind:ASCE 7-10;Vult=115mph(3-second gust)Vasd=91mph;TCDL=6.0psf;BCDL=6.0psf; h=25ft; Cat. II;Exp C; enclosed; MWFRS(envelope) gable end zone and C-CExterior(2) 0-0-0 to 3-0-0,Interior(1) 3-0-0 to 19-5-2,Exterior(2) 19-5-2 to 20-10-4 zone;cantileverleft exposed ; end verticalleft exposed;C-C formembers and forces&MWFRS forreactionsshown; Lumber DOL=1.60 plate grip DOL=1.603)TCLL:ASCE 7-10;Pr=20.0 psf(roofliveload: Lumber DOL=1.15Plate DOL=1.15);Pg=20.0 psf(groundsnow);Pf=20.4 psf(flat roofsnow: Lumber DOL=1.15Plate DOL=1.15); CategoryII;Exp C; PartiallyExp.; Ct=1.1, Lu=50-0-0;Min. flatroofsnowload governs. Rainsurcharge applied to all exposedsurfaceswithslopesless than 0.500/12 in accordancewithIBC 1608.3.4.4) Unbalancedsnowloads have been considered for this design. 5)Provide adequate drainage to preventwater ponding. 6)This truss has been designed for a 10.0 psf bottomchordliveload nonconcurrentwith any otherliveloads.7) Refer to girder(s) for truss to trussconnections. 8)Providemechanicalconnection(by others) of truss to bearing platecapable of withstanding 100 lb uplift at joint(s) 1 except(jt=lb) 8=233.9)This trussis designedin accordancewith the 2012 InternationalBuilding Code section 2306.1 and referencedstandardANSI/TPI 1. LOADCASE(S)Standard DE Job # 59223-W1 Dansco Engineering, LLC Date: 6/13/18 WARNING – VERIFY DESIGN PARAMETERS AND READ NOTES BEFORE FABRICATION AND INSTALLATION!!! This truss design is adequate for the design parameters shown. Review and approval of design parameters is the responsibility of the building designer, not the truss designer or truss engineer. Permanent bracing requirements against out-of-plane buckling are noted/shown for individual truss members (and for the truss as a whole) subjected to gravity and wind loads. Additional permanent bracing design shall be the responsibility of the design professional of record. Temporary and erection bracing shall be the responsibility of the contractor. Reference ANSI/TPI-1, “National Design Standard for Metal Plate Connected Wood Truss Construction” and TPI/WTCA BCSI-06, “Building Component Safety Information Guide to Good Practice for Handling, Installing, Restraining and Bracing of Metal Plate Connected Wood Trusses” for additional information. Job 1802242-12T Truss T12 TrussType Jack-Closed Qty 5 Ply 1 1802242-12TDWHWoodside-West Clay- 4 Job Reference (optional)Run:8.200 s Apr72018 Print:8.200 s Apr72018MiTekIndustries,Inc.Tue Jun1221:11:562018 Page1ID:bRTO9oDnRLEHvJjVgeMKW3yF_s1-oxngvSHWUYS6Vq5m4tHsXVI3KRRsHTy?dHzZK8z6wGX Scale=1:71.0 T2 W7 B1 B3 B4W1W2 W3 W5 W4 W6 T1 B2 1 2 3 4 5 6 13 12 11 109 8 7 17 18 19 3x4 3x6 1.5x43x43x4 3x5 2x4 6x10 3x4 1.5x4 4x8 3x4 6-11-3 6-11-3 13-5-10 6-6-6 20-0-0 6-6-6 21-0-0 1-0-0 6-11-3 6-11-3 13-5-10 6-6-6 20-0-0 6-6-6 21-0-0 1-0-0 0 -5 -0 10 -11 -0 9 -11 -0 1 -0 -0 6.0012 PlateOffsets(X,Y)-- [1:0-0-0,0-0-9], [8:0-4-4,0-2-12] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 10.0 SPACING- PlateGrip DOL Lumber DOL RepStressIncr Code 2-0-0 1.15 1.15 YES IBC2012/TPI2007 CSI. TC BC WB Matrix-MSH 0.41 0.42 0.57 DEFL. Vert(LL) Vert(TL) Horz(TL) in 0.06 -0.15 0.03 (loc) 13-16 13-16 7 l/defl >999 >999 n/a L/d 240 180 n/a PLATES MT20 Weight: 120 lb FT= 20% GRIP 197/144 LUMBER- TOP CHORD2x4SPF No.2BOT CHORD2x4SPF No.2 WEBS 2x4SPF No.2 *Except* W1,W3,W5: 2x4SPFStud BRACING- TOP CHORD Structuralwoodsheathing directly applied or 4-7-5 oc purlins,except end verticals. BOT CHORD Rigidceiling directly applied or 9-2-7 oc bracing.Except: 1 Row at midpt 5-810-0-0 oc bracing: 8-10 WEBS 1 Row at midpt 6-7, 4-8 MiTekrecommends that Stabilizers and requiredcross bracing beinstalled during truss erection,in accordancewithStabilizerInstallation guide. REACTIONS.(lb/size)7=745/0-6-0(min. 0-1-8), 1=744/Mechanical Max Horz1=425(LC 16)Max Uplift7=-274(LC 16), 1=-69(LC 16) MaxGrav7=872(LC 22), 1=841(LC 2) FORCES.(lb)-Max. Comp./Max.Ten.-All forces 250 (lb) orless exceptwhenshown. TOP CHORD 1-17=-1357/44, 2-17=-1274/65, 2-3=-786/0, 3-4=-629/10, 6-7=-689/222 BOT CHORD 1-13=-396/1140, 12-13=-396/1140, 11-12=-396/1140, 5-8=-408/226 WEBS 2-13=0/267, 2-11=-590/213, 4-11=0/436, 8-11=-197/434, 4-8=-711/236, 6-8=-291/830 NOTES- 1)Wind:ASCE 7-10;Vult=115mph(3-second gust)Vasd=91mph;TCDL=6.0psf;BCDL=6.0psf; h=25ft; Cat. II;Exp C; enclosed; MWFRS(envelope) gable end zone and C-CExterior(2) 0-0-0 to 3-0-0,Interior(1) 3-0-0 to 20-10-4zone;cantileverleft exposed ; endverticalleft exposed;C-C formembers and forces&MWFRS forreactionsshown; Lumber DOL=1.60 plate grip DOL=1.60 2)TCLL:ASCE 7-10;Pr=20.0 psf(roofliveload: Lumber DOL=1.15Plate DOL=1.15);Pg=20.0 psf(groundsnow);Pf=15.4 psf(flat roofsnow: Lumber DOL=1.15Plate DOL=1.15); CategoryII;Exp C; PartiallyExp.; Ct=1.1 3) Unbalancedsnowloads have been considered for this design. 4)This truss has been designed for a 10.0 psf bottomchordliveload nonconcurrentwith any otherliveloads.5) Refer to girder(s) for truss to trussconnections. 6)Providemechanicalconnection(by others) of truss to bearing platecapable of withstanding 100 lb uplift at joint(s) 1 except(jt=lb) 7=274.7)This trussis designedin accordancewith the 2012 InternationalBuilding Code section 2306.1 and referencedstandardANSI/TPI 1. LOADCASE(S)Standard DE Job # 59223-W1 Dansco Engineering, LLC Date: 6/13/18 WARNING – VERIFY DESIGN PARAMETERS AND READ NOTES BEFORE FABRICATION AND INSTALLATION!!! This truss design is adequate for the design parameters shown. Review and approval of design parameters is the responsibility of the building designer, not the truss designer or truss engineer. Permanent bracing requirements against out-of-plane buckling are noted/shown for individual truss members (and for the truss as a whole) subjected to gravity and wind loads. Additional permanent bracing design shall be the responsibility of the design professional of record. Temporary and erection bracing shall be the responsibility of the contractor. Reference ANSI/TPI-1, “National Design Standard for Metal Plate Connected Wood Truss Construction” and TPI/WTCA BCSI-06, “Building Component Safety Information Guide to Good Practice for Handling, Installing, Restraining and Bracing of Metal Plate Connected Wood Trusses” for additional information. Job 1802242-12T Truss T13 TrussType Jack-Closed Qty 2 Ply 1 1802242-12TDWHWoodside-West Clay- 4 Job Reference (optional)Run:8.200 s Apr72018 Print:8.200 s Apr72018MiTekIndustries,Inc.Tue Jun1221:11:572018 Page1ID:bRTO9oDnRLEHvJjVgeMKW3yF_s1-G7L26oH8Fsaz6_gydbo54iq53reO0vD8sxj7saz6wGW Scale=1:70.3 T2 W7 B1 B3 B4W1W2 W3 W5 W4 W6 T1 1 2 3 4 5 6 7 14 13 12 1110 9 8 18 19 20 3x4 3x8 2x4 5x6 4x6 4x4 3x4 6x10 3x4 1.5x4 5x8 3x5 5-3-8 5-3-8 12-7-12 7-4-4 20-0-0 7-4-4 21-0-0 1-0-0 -1-2-12 1-2-12 5-3-8 5-3-8 12-7-12 7-4-4 20-0-0 7-4-4 21-0-0 1-0-0 0 -5 -0 10 -11 -0 9 -11 -0 1 -0 -0 6.0012 PlateOffsets(X,Y)-- [2:0-0-0,0-1-1], [7:0-3-3,0-1-8], [9:0-4-4,0-2-12], [11:0-2-0,0-0-8] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 10.0 SPACING- PlateGrip DOL Lumber DOL RepStressIncr Code 2-0-0 1.15 1.15 NO IBC2012/TPI2007 CSI. TC BC WB Matrix-MSH 0.92 0.98 0.63 DEFL. Vert(LL) Vert(TL) Horz(TL) in -0.12 -0.33 0.07 (loc) 12-14 12-14 8 l/defl >999 >748 n/a L/d 240 180 n/a PLATES MT20 Weight: 121 lb FT= 20% GRIP 197/144 LUMBER- TOP CHORD2x4SPF 1650F 1.5E*Except*T1: 2x4SPF No.2 BOT CHORD2x4SPF No.2 *Except* B1: 2x4SPF 1650F 1.5EWEBS2x4SPF No.2 *Except* W1,W3: 2x4SPFStud BRACING- TOP CHORD Structuralwoodsheathing directly applied, except end verticals.BOT CHORD Rigidceiling directly applied or 6-6-14 oc bracing.Except: 1 Row at midpt 6-9 10-0-0 oc bracing: 9-11WEBS1 Row at midpt 7-8, 3-12, 5-9 MiTekrecommends that Stabilizers and requiredcross bracing beinstalled during truss erection,in accordancewithStabilizer Installation guide.REACTIONS.(lb/size)8=1195/0-6-0(min. 0-2-2), 2=1590/0-6-0(min. 0-2-13) Max Horz2=447(LC 16) Max Uplift8=-381(LC 16), 2=-283(LC 16)MaxGrav8=1349(LC 2), 2=1800(LC 2) FORCES.(lb)-Max. Comp./Max.Ten.-All forces 250 (lb) orless exceptwhenshown.TOP CHORD 2-18=-3389/472, 3-18=-3271/491, 3-4=-1630/131, 4-5=-1313/137, 5-19=-323/0, 6-7=-261/82, 7-8=-1066/305 BOT CHORD 2-14=-804/2986, 13-14=-804/2986, 12-13=-804/2986, 11-12=-24/304, 6-9=-541/274 WEBS 3-12=-1798/470, 5-12=-33/712, 9-12=-343/1002, 5-9=-1426/394, 7-9=-404/1267 NOTES- 1)Wind:ASCE 7-10;Vult=115mph(3-second gust)Vasd=91mph;TCDL=6.0psf;BCDL=6.0psf; h=25ft; Cat. II;Exp C; enclosed; MWFRS(envelope) gable end zone and C-CExterior(2)-1-2-12 to 1-9-4,Interior(1) 1-9-4 to 20-10-4zone;cantileverleft exposed ; endverticalleft exposed;C-C formembers and forces&MWFRS forreactionsshown; Lumber DOL=1.60 plate grip DOL=1.60 2)TCLL:ASCE 7-10;Pr=20.0 psf(roofliveload: Lumber DOL=1.15Plate DOL=1.15);Pg=20.0 psf(groundsnow);Pf=15.4 psf(flat roofsnow: Lumber DOL=1.15Plate DOL=1.15); CategoryII;Exp C; PartiallyExp.; Ct=1.1 3) Unbalancedsnowloads have been considered for this design. 4)This truss has been designed for greater of minroofliveload of 12.0 psf or 2.00 times flatroofload of 15.4 psf on overhangsnon-concurrentwith otherliveloads. 5)This truss has been designed for a 10.0 psf bottomchordliveload nonconcurrentwith any otherliveloads. 6)Providemechanicalconnection(by others) of truss to bearing platecapable of withstanding 100 lb uplift at joint(s) except(jt=lb)8=381, 2=283. 7)This trussis designedin accordancewith the 2012 InternationalBuilding Code section 2306.1 and referencedstandardANSI/TPI 1. 8) Hanger(s) or otherconnection device(s)shall be providedsufficient to supportconcentratedload(s) 870 lb down and 229 lb up at 5-3-8 on top chord.The design/selection of suchconnection device(s)is the responsibility of others. LOADCASE(S)Standard1) Dead +Snow(balanced): LumberIncrease=1.15,PlateIncrease=1.15 Uniform Loads(plf) Vert: 1-3=-51, 11-15=-20, 10-11=-20, 8-9=-20 Continued on page 2 DE Job # 59223-W1 Dansco Engineering, LLC Date: 6/13/18 WARNING – VERIFY DESIGN PARAMETERS AND READ NOTES BEFORE FABRICATION AND INSTALLATION!!! This truss design is adequate for the design parameters shown. Review and approval of design parameters is the responsibility of the building designer, not the truss designer or truss engineer. Permanent bracing requirements against out-of-plane buckling are noted/shown for individual truss members (and for the truss as a whole) subjected to gravity and wind loads. Additional permanent bracing design shall be the responsibility of the design professional of record. Temporary and erection bracing shall be the responsibility of the contractor. Reference ANSI/TPI-1, “National Design Standard for Metal Plate Connected Wood Truss Construction” and TPI/WTCA BCSI-06, “Building Component Safety Information Guide to Good Practice for Handling, Installing, Restraining and Bracing of Metal Plate Connected Wood Trusses” for additional information. Job 1802242-12T Truss T13 TrussType Jack-Closed Qty 2 Ply 1 1802242-12TDWHWoodside-West Clay- 4 Job Reference (optional)Run:8.200 s Apr72018 Print:8.200 s Apr72018MiTekIndustries,Inc.Tue Jun1221:11:572018 Page2ID:bRTO9oDnRLEHvJjVgeMKW3yF_s1-G7L26oH8Fsaz6_gydbo54iq53reO0vD8sxj7saz6wGW LOADCASE(S)Standard Concentrated Loads(lb) Vert: 3=-770Trapezoidal Loads(plf) Vert: 3=-101-to-7=-60 DE Job # 59223-W1 Dansco Engineering, LLC Date: 6/13/18 WARNING – VERIFY DESIGN PARAMETERS AND READ NOTES BEFORE FABRICATION AND INSTALLATION!!! This truss design is adequate for the design parameters shown. Review and approval of design parameters is the responsibility of the building designer, not the truss designer or truss engineer. Permanent bracing requirements against out-of-plane buckling are noted/shown for individual truss members (and for the truss as a whole) subjected to gravity and wind loads. Additional permanent bracing design shall be the responsibility of the design professional of record. Temporary and erection bracing shall be the responsibility of the contractor. Reference ANSI/TPI-1, “National Design Standard for Metal Plate Connected Wood Truss Construction” and TPI/WTCA BCSI-06, “Building Component Safety Information Guide to Good Practice for Handling, Installing, Restraining and Bracing of Metal Plate Connected Wood Trusses” for additional information. Job 1802242-12T Truss T14 TrussType Jack-Closed Qty 2 Ply 1 1802242-12TDWHWoodside-West Clay- 4 Job Reference (optional)Run:8.200 s Apr72018 Print:8.200 s Apr72018MiTekIndustries,Inc.Tue Jun1221:11:582018 Page1ID:bRTO9oDnRLEHvJjVgeMKW3yF_s1-kKvQK8Im0Aiqk8F8BIJKcwNGJF0YlMHI5bSgP1z6wGV Scale=1:70.5 T2 W7 B1 B3 B4W1 W2 W3 W5 W4 W6 T1 1 2 3 4 5 6 7 14 13 12 11 10 9 8 18 19 20 3x4 4x4 5x6 5x6 4x6 3x5 4x6 3x4 1.5x4 5x8 3x4 4x10 5-3-8 5-3-8 12-7-12 7-4-4 20-0-0 7-4-4 22-0-0 2-0-0 -1-2-12 1-2-12 5-3-8 5-3-8 12-7-12 7-4-4 20-0-0 7-4-4 22-0-0 2-0-0 0 -5 -0 11 -5 -0 10 -5 -0 1 -0 -0 6.0012 PlateOffsets(X,Y)-- [2:0-0-0,0-1-1], [9:0-7-0,0-2-4] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 10.0 SPACING- PlateGrip DOL Lumber DOL RepStressIncr Code 2-0-0 1.15 1.15 NO IBC2012/TPI2007 CSI. TC BC WB Matrix-MSH 0.95 0.79 0.58 DEFL. Vert(LL) Vert(TL) Horz(TL) in 0.13 -0.35 0.08 (loc) 12-14 12-14 8 l/defl >999 >741 n/a L/d 240 180 n/a PLATES MT20 Weight: 126 lb FT= 20% GRIP 197/144 LUMBER- TOP CHORD2x4SPF 1650F 1.5E*Except*T1: 2x4SPF No.2 BOT CHORD2x4SPF 1650F 1.5E*Except* B3,B4: 2x4SPF No.2WEBS2x4SPF No.2 *Except* W1,W3,W5: 2x4SPFStud BRACING- TOP CHORD Structuralwoodsheathing directly applied, except end verticals.BOT CHORD Rigidceiling directly applied or 7-9-8 oc bracing.Except: 10-0-0 oc bracing: 9-11 WEBS 1 Row at midpt 3-12, 5-9, 6-8 MiTekrecommends that Stabilizers and requiredcross bracingbeinstalled during truss erection,in accordancewithStabilizer Installation guide. REACTIONS.(lb/size)8=1237/0-6-0(min. 0-2-3), 2=1648/0-6-0(min. 0-2-15)Max Horz2=452(LC 13) Max Uplift8=-325(LC 16), 2=-345(LC 16) MaxGrav8=1394(LC 2), 2=1865(LC 2) FORCES.(lb)-Max. Comp./Max.Ten.-All forces 250 (lb) orless exceptwhenshown. TOP CHORD 2-18=-3525/678, 3-18=-3407/701, 3-4=-1772/342, 4-5=-1456/342, 5-19=-556/172,19-20=-414/179, 6-20=-388/190 BOT CHORD 2-14=-852/3107, 13-14=-852/3107, 12-13=-852/3107, 6-9=-254/1077, 8-9=-173/332 WEBS 3-12=-1811/464, 5-12=-41/678, 9-12=-409/1254, 5-9=-1395/401, 6-8=-1411/415 NOTES- 1)Wind:ASCE 7-10;Vult=115mph(3-second gust)Vasd=91mph;TCDL=6.0psf;BCDL=6.0psf; h=25ft; Cat. II;Exp C; enclosed; MWFRS(envelope) gable end zone and C-CExterior(2)-1-2-12 to 1-9-4,Interior(1) 1-9-4 to 21-10-4zone;cantileverleft and right exposed ; end verticalleft and right exposed;C-C formembers and forces&MWFRS forreactionsshown; Lumber DOL=1.60 plate grip DOL=1.60 2)TCLL:ASCE 7-10;Pr=20.0 psf(roofliveload: Lumber DOL=1.15Plate DOL=1.15);Pg=20.0 psf(groundsnow);Pf=15.4 psf(flat roofsnow: Lumber DOL=1.15Plate DOL=1.15); CategoryII;Exp C; PartiallyExp.; Ct=1.1 3) Unbalancedsnowloads have been considered for this design. 4)This truss has been designed for greater of minroofliveload of 12.0 psf or 2.00 times flatroofload of 15.4 psf on overhangs non-concurrentwith otherliveloads. 5)This truss has been designed for a 10.0 psf bottomchordliveload nonconcurrentwith any otherliveloads. 6)Providemechanicalconnection(by others) of truss to bearing platecapable of withstanding 100 lb uplift at joint(s) except(jt=lb)8=325, 2=345. 7)This trussis designedin accordancewith the 2012 InternationalBuilding Code section 2306.1 and referencedstandardANSI/TPI 1. 8) Hanger(s) or otherconnection device(s)shall be providedsufficient to supportconcentratedload(s) 937 lb down and 229 lb up at 5-3-8 on top chord.The design/selection of suchconnection device(s)is the responsibility of others. LOADCASE(S)Standard1) Dead +Snow(balanced): LumberIncrease=1.15,PlateIncrease=1.15 Uniform Loads(plf) Vert: 1-3=-51, 11-15=-20, 10-11=-20, 8-9=-20 Continued on page 2 DE Job # 59223-W1 Dansco Engineering, LLC Date: 6/13/18 WARNING – VERIFY DESIGN PARAMETERS AND READ NOTES BEFORE FABRICATION AND INSTALLATION!!! This truss design is adequate for the design parameters shown. Review and approval of design parameters is the responsibility of the building designer, not the truss designer or truss engineer. Permanent bracing requirements against out-of-plane buckling are noted/shown for individual truss members (and for the truss as a whole) subjected to gravity and wind loads. Additional permanent bracing design shall be the responsibility of the design professional of record. Temporary and erection bracing shall be the responsibility of the contractor. Reference ANSI/TPI-1, “National Design Standard for Metal Plate Connected Wood Truss Construction” and TPI/WTCA BCSI-06, “Building Component Safety Information Guide to Good Practice for Handling, Installing, Restraining and Bracing of Metal Plate Connected Wood Trusses” for additional information. Job 1802242-12T Truss T14 TrussType Jack-Closed Qty 2 Ply 1 1802242-12TDWHWoodside-West Clay- 4 Job Reference (optional)Run:8.200 s Apr72018 Print:8.200 s Apr72018MiTekIndustries,Inc.Tue Jun1221:11:582018 Page2ID:bRTO9oDnRLEHvJjVgeMKW3yF_s1-kKvQK8Im0Aiqk8F8BIJKcwNGJF0YlMHI5bSgP1z6wGV LOADCASE(S)Standard Concentrated Loads(lb) Vert: 3=-770Trapezoidal Loads(plf) Vert: 3=-101-to-7=-58 DE Job # 59223-W1 Dansco Engineering, LLC Date: 6/13/18 WARNING – VERIFY DESIGN PARAMETERS AND READ NOTES BEFORE FABRICATION AND INSTALLATION!!! This truss design is adequate for the design parameters shown. Review and approval of design parameters is the responsibility of the building designer, not the truss designer or truss engineer. Permanent bracing requirements against out-of-plane buckling are noted/shown for individual truss members (and for the truss as a whole) subjected to gravity and wind loads. Additional permanent bracing design shall be the responsibility of the design professional of record. Temporary and erection bracing shall be the responsibility of the contractor. Reference ANSI/TPI-1, “National Design Standard for Metal Plate Connected Wood Truss Construction” and TPI/WTCA BCSI-06, “Building Component Safety Information Guide to Good Practice for Handling, Installing, Restraining and Bracing of Metal Plate Connected Wood Trusses” for additional information. Job 1802242-12T Truss T15 TrussType Jack-Closed Qty 3 Ply 1 1802242-12TDWHWoodside-West Clay- 4 Job Reference (optional)Run:8.200 s Apr72018 Print:8.200 s Apr72018MiTekIndustries,Inc.Tue Jun1221:11:592018 Page1ID:bRTO9oDnRLEHvJjVgeMKW3yF_s1-CWSpXTJPnTqhMIpLl0rZ97wb2fUCUsHRJECExTz6wGU Scale=1:39.6 W1 T1 W4 B1 W2 W31 2 3 6 5 4 7 8 9 3x10 2x4 1.5x4 3x4 3x4 5-8-4 5-8-4 11-4-8 5-8-4 5-8-4 5-8-4 11-4-8 5-8-4 0 -10 -12 6 -7 -0 6.0012 PlateOffsets(X,Y)-- [1:0-1-6,0-2-12], [6:0-2-11,0-0-4], [6:0-0-0,0-2-12] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 10.0 SPACING- PlateGrip DOL Lumber DOL RepStressIncr Code 2-0-0 1.15 1.15 YES IBC2012/TPI2007 CSI. TC BC WB Matrix-MSH 0.31 0.32 0.40 DEFL. Vert(LL) Vert(TL) Horz(TL) in 0.06 -0.10 0.01 (loc) 4-5 4-5 4 l/defl >999 >999 n/a L/d 240 180 n/a PLATES MT20 Weight: 46 lb FT= 20% GRIP 197/144 LUMBER- TOP CHORD2x4SPF No.2BOT CHORD2x4SPF No.2 WEBS 2x4SPFStud*Except* W1: 2x6SPF No.2 BRACING- TOP CHORD Structuralwoodsheathing directly applied or 6-0-0 oc purlins,except end verticals. BOT CHORD Rigidceiling directly applied or 8-7-14 oc bracing. MiTekrecommends that Stabilizers and requiredcross bracing beinstalled during truss erection,in accordancewithStabilizerInstallation guide. REACTIONS.(lb/size)6=389/Mechanical, 4=389/0-6-0(min. 0-1-8) Max Horz6=215(LC 16)Max Uplift6=-22(LC 16), 4=-163(LC 16) MaxGrav6=440(LC 2), 4=440(LC 2) FORCES.(lb)-Max. Comp./Max.Ten.-All forces 250 (lb) orless exceptwhenshown. TOP CHORD 1-6=-365/227, 1-7=-524/296, 2-7=-392/313 BOT CHORD 5-6=-432/403, 4-5=-432/403WEBS2-5=-254/227, 2-4=-461/495 NOTES- 1)Wind:ASCE 7-10;Vult=115mph(3-second gust)Vasd=91mph;TCDL=6.0psf;BCDL=6.0psf; h=25ft; Cat. II;Exp C; enclosed; MWFRS(envelope) gable end zone and C-CExterior(2) 0-2-12 to 3-2-12,Interior(1) 3-2-12 to 11-2-12zone;cantileverleft exposed ; end verticalleft exposed; porchleft exposed;C-C formembers and forces&MWFRS forreactionsshown; Lumber DOL=1.60 plate grip DOL=1.60 2)TCLL:ASCE 7-10;Pr=20.0 psf(roofliveload: Lumber DOL=1.15Plate DOL=1.15);Pg=20.0 psf(groundsnow);Pf=15.4 psf(flat roofsnow: Lumber DOL=1.15Plate DOL=1.15); CategoryII;Exp C; PartiallyExp.; Ct=1.1 3) Unbalancedsnowloads have been considered for this design. 4)This truss has been designed for a 10.0 psf bottomchordliveload nonconcurrentwith any otherliveloads. 5) Refer to girder(s) for truss to trussconnections. 6)Providemechanicalconnection(by others) of truss to bearing platecapable of withstanding 100 lb uplift at joint(s) 6 except(jt=lb) 4=163. 7)This trussis designedin accordancewith the 2012 InternationalBuilding Code section 2306.1 and referencedstandardANSI/TPI 1. LOADCASE(S)Standard DE Job # 59223-W1 Dansco Engineering, LLC Date: 6/13/18 WARNING – VERIFY DESIGN PARAMETERS AND READ NOTES BEFORE FABRICATION AND INSTALLATION!!! This truss design is adequate for the design parameters shown. Review and approval of design parameters is the responsibility of the building designer, not the truss designer or truss engineer. Permanent bracing requirements against out-of-plane buckling are noted/shown for individual truss members (and for the truss as a whole) subjected to gravity and wind loads. Additional permanent bracing design shall be the responsibility of the design professional of record. Temporary and erection bracing shall be the responsibility of the contractor. Reference ANSI/TPI-1, “National Design Standard for Metal Plate Connected Wood Truss Construction” and TPI/WTCA BCSI-06, “Building Component Safety Information Guide to Good Practice for Handling, Installing, Restraining and Bracing of Metal Plate Connected Wood Trusses” for additional information. Job 1802242-12T Truss T16 TrussType HalfHipGirder Qty 1 Ply 2 1802242-12TDWHWoodside-West Clay- 4 Job Reference (optional)Run:8.200 s Apr72018 Print:8.200 s Apr72018MiTekIndustries,Inc.Tue Jun1221:12:052018 Page1ID:bRTO9oDnRLEHvJjVgeMKW3yF_s1-1gq4oXO9NJbq4DHV5GyzPO9ey4SfuUTKiAfY87z6wGO Scale=1:65.5 0 -1 -14 T1 T2 W5 B1 W3 W4 W5 W4 W5 W4 W5 W4 W5 W4 W5 W4W1W2 T4T3 B3B2 1 2 3 4 5 6 7 8 9 10 20 19 18 17 16 15 14 13 12 11 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 6x6 4x8 5x8 2x42x4 4x84x44x6 4x4 4x4 4x4 2x4 4x8 4x4 4x4 4x4 4x8 4x6 4x8 4x8 3-8-10 3-8-10 9-0-12 5-4-2 14-6-11 5-5-14 20-0-9 5-5-14 25-6-7 5-5-14 31-0-6 5-5-14 36-8-0 5-7-10 3-8-10 3-8-10 9-0-12 5-4-2 14-6-11 5-5-14 20-0-9 5-5-14 25-6-7 5-5-14 31-0-6 5-5-14 36-8-0 5-7-10 1 -1 -02-9 -7 2 -11 -5 2 -9 -7 6.0012 PlateOffsets(X,Y)-- [2:0-3-0,0-0-12], [12:0-3-8,0-2-0] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 10.0 SPACING- PlateGrip DOL Lumber DOL RepStressIncr Code 2-0-0 1.15 1.15 NO IBC2012/TPI2007 CSI. TC BC WB Matrix-MSH 0.22 0.63 0.80 DEFL. Vert(LL) Vert(TL) Horz(TL) in 0.32 -0.52 0.08 (loc) 15-17 15-17 11 l/defl >999 >836 n/a L/d 240 180 n/a PLATES MT20 Weight: 410 lb FT= 20% GRIP 197/144 LUMBER- TOP CHORD2x6SP 2400F 2.0E*Except*T1: 2x4SPF No.2 BOT CHORD2x6SPF No.2 WEBS 2x4SPFStud BRACING- TOP CHORD Structuralwoodsheathing directly applied or 6-0-0 oc purlins,except end verticals. BOT CHORD Rigidceiling directly applied or 9-3-2 oc bracing. REACTIONS.(lb/size)11=1473/0-6-0(min. 0-1-8), 20=1439/0-6-0(min. 0-1-8) Max Horz20=92(LC 9)Max Uplift11=-804(LC 9), 20=-790(LC 9) MaxGrav11=1766(LC 30), 20=1614(LC 30) FORCES.(lb)-Max. Comp./Max.Ten.-All forces 250 (lb) orless exceptwhenshown. TOP CHORD 1-21=-2481/1232, 2-21=-2437/1219, 2-22=-4994/2366, 22-23=-4996/2366, 3-23=-5002/2367, 3-24=-6284/3009, 24-25=-6284/3009, 25-26=-6284/3009, 4-26=-6284/3009, 4-27=-6374/3117, 5-27=-6374/3117, 5-28=-6374/3117, 6-28=-6374/3117, 6-29=-6374/3117, 29-30=-6374/3117, 30-31=-6374/3117, 7-31=-6374/3117, 7-32=-5527/2644, 8-32=-5527/2644, 8-9=-5527/2644, 9-33=-3511/1632, 33-34=-3511/1632, 34-35=-3511/1632, 10-35=-3511/1632, 10-11=-1689/791, 1-20=-1565/794 BOT CHORD 19-37=-1166/2230, 37-38=-1166/2230, 18-38=-1166/2230, 18-39=-2401/4994, 39-40=-2401/4994, 40-41=-2401/4994, 17-41=-2401/4994, 17-42=-3040/6284, 16-42=-3040/6284, 16-43=-3040/6284, 43-44=-3040/6284, 15-44=-3040/6284, 15-45=-2656/5527, 14-45=-2656/5527, 14-46=-2656/5527, 13-46=-2656/5527, 13-47=-1635/3511, 47-48=-1635/3511, 12-48=-1635/3511 WEBS 2-19=-365/223, 2-18=-1373/3046, 3-18=-1181/587, 3-17=-704/1408, 4-17=-444/283, 6-15=-342/250, 7-15=-525/960, 7-13=-749/438, 9-13=-1109/2195, 9-12=-1365/692, 10-12=-1720/3734, 1-19=-1023/2117 NOTES- 1) 2-ply truss to be connected togetherwith 10d (0.131"x3") nails as follows:Topchordsconnected as follows: 2x4- 1 row at 0-9-0 oc, 2x6- 2 rowsstaggered at 0-9-0 oc. Bottomchordsconnected as follows: 2x6- 2 rowsstaggered at 0-9-0 oc. Websconnected as follows: 2x4- 1 row at 0-9-0 oc.2)Allloads areconsidered equally applied to all plies, exceptif noted as front(F) or back(B) facein the LOAD CASE(S)section.Ply to plyconnections have been provided to distribute onlyloads noted as(F) or(B), unless otherwiseindicated. 3) Unbalancedroofliveloads have been considered for this design.4)Wind:ASCE 7-10;Vult=115mph(3-second gust)Vasd=91mph;TCDL=6.0psf;BCDL=6.0psf; h=25ft; Cat. II;Exp C; enclosed; MWFRS(envelope) gable end zone;cantileverleft and right exposed ; end verticalleft and right exposed; Lumber DOL=1.60 plate grip DOL=1.60 5)TCLL:ASCE 7-10;Pr=20.0 psf(roofliveload: Lumber DOL=1.15Plate DOL=1.15);Pg=20.0 psf(groundsnow);Pf=20.4 psf(flat roofsnow: Lumber DOL=1.15Plate DOL=1.15); CategoryII;Exp C; PartiallyExp.; Ct=1.1, Lu=50-0-0;Min. flatroofsnowload governs. Rainsurcharge applied to all exposedsurfaceswithslopesless than 0.500/12 in accordancewithIBC 1608.3.4.Continued on page 2 DE Job # 59223-W1 Dansco Engineering, LLC Date: 6/13/18 WARNING – VERIFY DESIGN PARAMETERS AND READ NOTES BEFORE FABRICATION AND INSTALLATION!!! This truss design is adequate for the design parameters shown. Review and approval of design parameters is the responsibility of the building designer, not the truss designer or truss engineer. Permanent bracing requirements against out-of-plane buckling are noted/shown for individual truss members (and for the truss as a whole) subjected to gravity and wind loads. Additional permanent bracing design shall be the responsibility of the design professional of record. Temporary and erection bracing shall be the responsibility of the contractor. Reference ANSI/TPI-1, “National Design Standard for Metal Plate Connected Wood Truss Construction” and TPI/WTCA BCSI-06, “Building Component Safety Information Guide to Good Practice for Handling, Installing, Restraining and Bracing of Metal Plate Connected Wood Trusses” for additional information. Job 1802242-12T Truss T16 TrussType HalfHipGirder Qty 1 Ply 2 1802242-12TDWHWoodside-West Clay- 4 Job Reference (optional)Run:8.200 s Apr72018 Print:8.200 s Apr72018MiTekIndustries,Inc.Tue Jun1221:12:062018 Page2ID:bRTO9oDnRLEHvJjVgeMKW3yF_s1-VsNS?tOo8djhiNshf_TCxcipiToudxjTwqO5hZz6wGN NOTES- 6) Unbalancedsnowloads have been considered for this design. 7)Provide adequate drainage to preventwater ponding. 8)This truss has been designed for a 10.0 psf bottomchordliveload nonconcurrentwith any otherliveloads.9)Providemechanicalconnection(by others) of truss to bearing platecapable of withstanding 100 lb uplift at joint(s) except(jt=lb) 11=804, 20=790. 10)This trussis designedin accordancewith the 2012 InternationalBuilding Code section 2306.1 and referencedstandardANSI/TPI 1. 11) Hanger(s) or otherconnection device(s)shall be providedsufficient to supportconcentratedload(s) 50 lb down and 76 lb up at 1-8-9, 150 lb down and 149 lb up at 3-8-10, 77 lb down and 61 lb up at 5-8-2, 77 lb down and 61 lb up at 7-8-2, 77 lb down and 61 lb up at 9-8-2, 77 lb down and 61 lb up at 11-8-2, 77 lb down and 61 lb up at 13-8-2, 77 lb down and 61 lb up at 15-8-2, 77 lb down and 61 lb up at 17-8-2, 77 lb down and 61 lb up at 19-8-2, 77 lb down and 61 lb up at 21-8-2, 77 lb down and 61 lb up at 23-8-2, 77 lb down and 61 lb up at 25-8-2, 77 lb down and 61 lb up at 27-8-2, 77 lb down and 61 lb up at 29-8-2, 77 lb down and 61 lb up at 31-8-2, and 77lb down and 61 lb up at 33-8-2, and 75 lb down and 61 lb up at 35-8-2 on top chord, and 4 lb down at 1-8-9, 38 lb down and 47 lb up at 3-8-10, 20 lb down and 22 lb up at 5-8-2, 20 lb down and 22 lb up at 7-8-2, 20 lb down and 22 lb up at 9-8-2, 20 lb down and 22 lb up at 11-8-2, 20 lb down and 22 lb up at 13-8-2, 20 lb down and 22lb up at 15-8-2, 20 lb down and 22 lb up at 17-8-2, 20 lb down and 22 lb up at 19-8-2, 20 lb down and 22 lb up at 21-8-2, 20 lb down and 22 lb up at 23-8-2, 20 lbdown and 22 lb up at 25-8-2, 20 lb down and 22 lb up at 27-8-2, 20 lb down and 22 lb up at 29-8-2, 20 lb down and 22 lb up at 31-8-2, and 20 lb down and 22 lb up at 33-8-2, and 21 lb down and 22 lb up at 35-8-2 on bottomchord.The design/selection of suchconnection device(s)is the responsibility of others. LOADCASE(S)Standard 1) Dead +Snow(balanced): LumberIncrease=1.15,PlateIncrease=1.15 Uniform Loads(plf) Vert: 1-2=-51, 2-10=-61, 11-20=-20 Concentrated Loads(lb) Vert: 19=1(B) 13=-0(B) 36=-1(B) 37=-0(B) 38=-0(B) 39=-0(B) 40=-0(B) 41=-0(B) 42=-0(B) 43=-0(B) 44=-0(B) 45=-0(B) 46=-0(B) 47=-0(B) 48=-0(B) 49=-0(B) 50=-0(B) 51=-2(B) DE Job # 59223-W1 Dansco Engineering, LLC Date: 6/13/18 WARNING – VERIFY DESIGN PARAMETERS AND READ NOTES BEFORE FABRICATION AND INSTALLATION!!! This truss design is adequate for the design parameters shown. Review and approval of design parameters is the responsibility of the building designer, not the truss designer or truss engineer. Permanent bracing requirements against out-of-plane buckling are noted/shown for individual truss members (and for the truss as a whole) subjected to gravity and wind loads. Additional permanent bracing design shall be the responsibility of the design professional of record. Temporary and erection bracing shall be the responsibility of the contractor. Reference ANSI/TPI-1, “National Design Standard for Metal Plate Connected Wood Truss Construction” and TPI/WTCA BCSI-06, “Building Component Safety Information Guide to Good Practice for Handling, Installing, Restraining and Bracing of Metal Plate Connected Wood Trusses” for additional information. Job 1802242-12T Truss T17 TrussType HalfHip Qty 1 Ply 1 1802242-12TDWHWoodside-West Clay- 4 Job Reference (optional)Run:8.200 s Apr72018 Print:8.200 s Apr72018MiTekIndustries,Inc.Tue Jun1221:12:072018 Page1ID:bRTO9oDnRLEHvJjVgeMKW3yF_s1-z2xqDDPQvxrYJWRtDh_RUpFs0t3wMNud9U8fD?z6wGM Scale=1:65.7 0 -1 -14 T1 T2 W6 B1 W3 W4 W5 W6 W5 W6 W5 W6 W5 W6 W5 W1 W2 T3 B3B2 1 2 3 4 5 6 7 8 9 17 16 15 14 13 12 11 10 18 19 20 21 22 3x4 6x6 4x8 5x8 3x4 3x10MT18H3x4 4x6 4x6 4x4 2x4 3x8 4x4 6x6 4x6 5x83x6 6-10-14 6-10-14 12-8-9 5-9-11 18-8-0 5-11-7 24-7-6 5-11-7 30-6-13 5-11-7 36-8-0 6-1-3 3-7-3 3-7-3 6-10-14 3-3-11 12-8-9 5-9-11 18-8-0 5-11-7 24-7-6 5-11-7 30-6-13 5-11-7 36-8-0 6-1-3 1 -1 -0 4 -4 -9 4 -6 -7 4 -4 -9 6.0012 PlateOffsets(X,Y)-- [3:0-3-4,0-0-12], [10:Edge,0-1-8], [11:0-3-8,0-2-8], [12:0-3-0,0-3-4] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 10.0 SPACING- PlateGrip DOL Lumber DOL RepStressIncr Code 2-0-0 1.15 1.15 YES IBC2012/TPI2007 CSI. TC BC WB Matrix-MSH 0.76 0.90 0.87 DEFL. Vert(LL) Vert(TL) Horz(TL) in -0.26 -0.57 0.16 (loc) 13 13-15 10 l/defl >999 >772 n/a L/d 240 180 n/a PLATES MT20 MT18H Weight: 177 lb FT= 20% GRIP 197/144 197/144 LUMBER- TOP CHORD2x6SPF No.2 *Except*T1: 2x4SPF No.2 BOT CHORD2x4SPF No.2 WEBS 2x4SPFStud*Except*W5: 2x4SPF No.2 BRACING- TOP CHORD Structuralwoodsheathing directly applied or 3-5-15 oc purlins,except end verticals. BOT CHORD Rigidceiling directly applied or 7-2-15 oc bracing. MiTekrecommends that Stabilizers and requiredcross bracing beinstalled during truss erection,in accordancewithStabilizerInstallation guide. REACTIONS.(lb/size)10=1463/0-6-0(min. 0-2-13), 17=1408/0-6-0(min. 0-2-6) Max Horz17=162(LC 13)Max Uplift10=-305(LC 13), 17=-200(LC 13) MaxGrav10=1789(LC 34), 17=1508(LC 34) FORCES.(lb)-Max. Comp./Max.Ten.-All forces 250 (lb) orless exceptwhenshown. TOP CHORD 2-19=-2454/384, 3-19=-2454/402, 3-20=-3587/605, 20-21=-3588/604, 4-21=-3595/603, 4-5=-3908/665, 5-6=-3908/665, 6-7=-3908/665, 7-8=-3449/600, 8-22=-2266/405,9-22=-2266/405, 9-10=-1732/332 BOT CHORD 16-17=-498/1867, 15-16=-442/2213, 14-15=-667/3587, 13-14=-667/3587, 12-13=-651/3457, 11-12=-425/2266 WEBS 2-16=-62/431, 3-15=-330/1689, 4-15=-868/260, 4-13=-111/423, 5-13=-398/171, 7-13=-99/543, 7-12=-686/220, 8-12=-269/1429, 8-11=-1386/344, 9-11=-472/2704, 2-17=-2159/361 NOTES- 1) Unbalancedroofliveloads have been considered for this design. 2)Wind:ASCE 7-10;Vult=115mph(3-second gust)Vasd=91mph;TCDL=6.0psf;BCDL=6.0psf; h=25ft; Cat. II;Exp C; enclosed; MWFRS(envelope) gable end zone and C-CExterior(2) 0-1-12 to 3-9-12,Interior(1) 3-9-12 to 6-10-14,Exterior(2) 6-10-14 to 12-1-2 zone;cantileverleft and right exposed ; end verticalleft and right exposed;C-C formembers and forces&MWFRS forreactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3)TCLL:ASCE 7-10;Pr=20.0 psf(roofliveload: Lumber DOL=1.15Plate DOL=1.15);Pg=20.0 psf(groundsnow);Pf=20.4 psf(flat roofsnow: Lumber DOL=1.15Plate DOL=1.15); CategoryII;Exp C; PartiallyExp.; Ct=1.1, Lu=50-0-0;Min. flatroofsnowload governs. Rainsurcharge applied to all exposedsurfaceswithslopesless than 0.500/12 in accordancewithIBC 1608.3.4.4) Unbalancedsnowloads have been considered for this design. 5)Provide adequate drainage to preventwater ponding. 6)All plates areMT20 plates unless otherwiseindicated.7)This truss has been designed for a 10.0 psf bottomchordliveload nonconcurrentwith any otherliveloads. 8)Providemechanicalconnection(by others) of truss to bearing platecapable of withstanding 100 lb uplift at joint(s) except(jt=lb) 10=305, 17=200.9)This trussis designedin accordancewith the 2012 InternationalBuilding Code section 2306.1 and referencedstandardANSI/TPI 1. LOADCASE(S)Standard DE Job # 59223-W1 Dansco Engineering, LLC Date: 6/13/18 WARNING – VERIFY DESIGN PARAMETERS AND READ NOTES BEFORE FABRICATION AND INSTALLATION!!! This truss design is adequate for the design parameters shown. Review and approval of design parameters is the responsibility of the building designer, not the truss designer or truss engineer. Permanent bracing requirements against out-of-plane buckling are noted/shown for individual truss members (and for the truss as a whole) subjected to gravity and wind loads. Additional permanent bracing design shall be the responsibility of the design professional of record. Temporary and erection bracing shall be the responsibility of the contractor. Reference ANSI/TPI-1, “National Design Standard for Metal Plate Connected Wood Truss Construction” and TPI/WTCA BCSI-06, “Building Component Safety Information Guide to Good Practice for Handling, Installing, Restraining and Bracing of Metal Plate Connected Wood Trusses” for additional information. Job 1802242-12T Truss T18 TrussType HalfHip Qty 1 Ply 1 1802242-12TDWHWoodside-West Clay- 4 Job Reference (optional)Run:8.200 s Apr72018 Print:8.200 s Apr72018MiTekIndustries,Inc.Tue Jun1221:12:082018 Page1ID:bRTO9oDnRLEHvJjVgeMKW3yF_s1-RFVCQYQ2fEzPxg?3nPVg01n_EHSN5pkmO8tClSz6wGL Scale=1:65.4 0 -1 -14 T1 T2 W7 B1 W3 W4 W5 W6 W7 W6 W7 W6 W7 W6 W1 W2 T3 B3B2 1 2 3 4 5 6 7 8 17 16 15 14 13 12 11 10 9 18 19 20 21 22 23 24 25 6x6 3x6 4x8 3x43x43x6 3x4 6x6 3x4 3x5 3x4 1.5x4 4x8 4x4 6x6 4x6 4x6 5-1-3 5-1-3 9-10-14 4-9-11 16-5-7 6-6-9 23-1-11 6-8-5 29-10-0 6-8-5 36-8-0 6-10-1 5-1-3 5-1-3 9-10-14 4-9-11 16-5-7 6-6-9 23-1-11 6-8-5 29-10-0 6-8-5 36-8-0 6-10-1 1 -1 -0 5 -10 -9 6 -0 -7 5 -10 -9 6.0012 PlateOffsets(X,Y)-- [9:Edge,0-1-8] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 10.0 SPACING- PlateGrip DOL Lumber DOL RepStressIncr Code 2-0-0 1.15 1.15 YES IBC2012/TPI2007 CSI. TC BC WB Matrix-MSH 0.92 0.76 0.90 DEFL. Vert(LL) Vert(TL) Horz(TL) in -0.20 -0.45 0.11 (loc) 11-13 11-13 9 l/defl >999 >973 n/a L/d 240 180 n/a PLATES MT20 Weight: 169 lb FT= 20% GRIP 197/144 LUMBER- TOP CHORD2x4SPF No.2BOT CHORD2x4SPF No.2 WEBS 2x4SPFStud*Except* W6: 2x4SPF No.2 BRACING- TOP CHORD Structuralwoodsheathing directly applied, except end verticals.BOT CHORD Rigidceiling directly applied or 7-11-7 oc bracing. WEBS 1 Row at midpt 8-9, 4-11 MiTekrecommends that Stabilizers and requiredcross bracing beinstalled during truss erection,in accordancewithStabilizerInstallation guide. REACTIONS.(lb/size)9=1456/0-6-0(min. 0-2-13), 17=1385/0-6-0(min. 0-2-5) Max Horz17=229(LC 13)Max Uplift9=-303(LC 13), 17=-154(LC 13) MaxGrav9=1807(LC 34), 17=1455(LC 2) FORCES.(lb)-Max. Comp./Max.Ten.-All forces 250 (lb) orless exceptwhenshown. TOP CHORD 1-18=-2211/347, 18-19=-2176/350, 19-20=-2163/362, 2-20=-2147/365, 2-3=-2322/401, 3-21=-2829/469, 21-22=-2830/468, 4-22=-2832/468, 4-23=-2669/431, 5-23=-2669/431,5-24=-2669/431, 6-24=-2669/431, 6-7=-2669/431, 7-25=-1813/321, 8-25=-1813/321, 8-9=-1745/332, 1-17=-1396/270 BOT CHORD 16-17=-307/311, 15-16=-551/1946, 14-15=-473/2068, 13-14=-473/2068, 12-13=-540/2829, 11-12=-540/2829, 10-11=-354/1813 WEBS 2-15=-274/203, 3-15=-15/279, 3-13=-219/1005, 4-13=-521/227, 5-11=-451/185, 7-11=-205/1115, 7-10=-1353/348, 8-10=-396/2330, 1-16=-248/1836 NOTES- 1) Unbalancedroofliveloads have been considered for this design. 2)Wind:ASCE 7-10;Vult=115mph(3-second gust)Vasd=91mph;TCDL=6.0psf;BCDL=6.0psf; h=25ft; Cat. II;Exp C; enclosed; MWFRS(envelope) gable end zone and C-CExterior(2) 0-1-12 to 3-9-12,Interior(1) 3-9-12 to 9-10-14,Exterior(2) 9-10-14 to 15-1-2 zone;cantileverleft and right exposed ; end verticalleft and right exposed;C-C formembers and forces&MWFRS forreactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3)TCLL:ASCE 7-10;Pr=20.0 psf(roofliveload: Lumber DOL=1.15Plate DOL=1.15);Pg=20.0 psf(groundsnow);Pf=20.4 psf(flat roofsnow: Lumber DOL=1.15Plate DOL=1.15); CategoryII;Exp C; PartiallyExp.; Ct=1.1, Lu=50-0-0;Min. flatroofsnowload governs. Rainsurcharge applied to all exposedsurfaceswithslopesless than 0.500/12 in accordancewithIBC 1608.3.4.4) Unbalancedsnowloads have been considered for this design. 5)Provide adequate drainage to preventwater ponding. 6)This truss has been designed for a 10.0 psf bottomchordliveload nonconcurrentwith any otherliveloads.7)Providemechanicalconnection(by others) of truss to bearing platecapable of withstanding 100 lb uplift at joint(s) except(jt=lb) 9=303, 17=154. 8)This trussis designedin accordancewith the 2012 InternationalBuilding Code section 2306.1 and referencedstandardANSI/TPI 1. LOADCASE(S)Standard DE Job # 59223-W1 Dansco Engineering, LLC Date: 6/13/18 WARNING – VERIFY DESIGN PARAMETERS AND READ NOTES BEFORE FABRICATION AND INSTALLATION!!! This truss design is adequate for the design parameters shown. Review and approval of design parameters is the responsibility of the building designer, not the truss designer or truss engineer. Permanent bracing requirements against out-of-plane buckling are noted/shown for individual truss members (and for the truss as a whole) subjected to gravity and wind loads. Additional permanent bracing design shall be the responsibility of the design professional of record. Temporary and erection bracing shall be the responsibility of the contractor. Reference ANSI/TPI-1, “National Design Standard for Metal Plate Connected Wood Truss Construction” and TPI/WTCA BCSI-06, “Building Component Safety Information Guide to Good Practice for Handling, Installing, Restraining and Bracing of Metal Plate Connected Wood Trusses” for additional information. Job 1802242-12T Truss T19 TrussType HalfHip Qty 1 Ply 1 1802242-12TDWHWoodside-West Clay- 4 Job Reference (optional)Run:8.200 s Apr72018 Print:8.200 s Apr72018MiTekIndustries,Inc.Tue Jun1221:12:092018 Page1ID:bRTO9oDnRLEHvJjVgeMKW3yF_s1-vR3bduRgQY5GZqaGK60vZEKA?hqqqIpvcodlHuz6wGK Scale=1:65.4 0 -1 -14 T1 T2 W8 B1 W3 W4 W5 W6 W7 W6 W7 W6 W1 W2 T3 B3B2 1 2 3 4 5 6 7 15 14 13 12 11 10 9 8 16 17 18 19 2021 22 6x6 3x6 5x6 3x53x43x6 3x4 6x6 3x4 1.5x4 3x10 3x4 5x6 4x6 3x6 6-7-3 6-7-3 12-10-14 6-3-11 20-8-3 7-9-5 28-7-3 7-11-1 36-8-0 8-0-13 6-7-3 6-7-3 12-10-14 6-3-11 20-8-3 7-9-5 28-7-3 7-11-1 36-8-0 8-0-13 1 -1 -0 7 -4 -9 7 -6 -7 7 -4 -9 6.0012 PlateOffsets(X,Y)-- [1:0-3-0,0-1-8], [8:Edge,0-1-8] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 10.0 SPACING- PlateGrip DOL Lumber DOL RepStressIncr Code 2-0-0 1.15 1.15 YES IBC2012/TPI2007 CSI. TC BC WB Matrix-MSH 0.86 0.62 0.78 DEFL. Vert(LL) Vert(TL) Horz(TL) in -0.14 -0.40 0.08 (loc) 11 11-13 8 l/defl >999 >999 n/a L/d 240 180 n/a PLATES MT20 Weight: 172 lb FT= 20% GRIP 197/144 LUMBER- TOP CHORD2x4SPF 1650F 1.5E*Except*T1: 2x4SPF No.2 BOT CHORD2x4SPF No.2 WEBS 2x4SPFStud*Except*W8,W4,W6: 2x4SPF No.2 BRACING- TOP CHORD Structuralwoodsheathing directly applied or 2-2-0 oc purlins,except end verticals. BOT CHORD Rigidceiling directly applied or 7-8-2 oc bracing. WEBS 1 Row at midpt 7-8, 3-11, 6-9 MiTekrecommends that Stabilizers and requiredcross bracingbeinstalled during truss erection,in accordancewithStabilizer Installation guide. REACTIONS.(lb/size)8=1447/0-6-0(min. 0-2-14), 15=1364/0-6-0(min. 0-2-5)Max Horz15=291(LC 13) Max Uplift8=-299(LC 13), 15=-156(LC 16) MaxGrav8=1824(LC 34), 15=1472(LC 35) FORCES.(lb)-Max. Comp./Max.Ten.-All forces 250 (lb) orless exceptwhenshown. TOP CHORD 1-16=-2272/331, 16-17=-2192/340, 17-18=-2174/345, 2-18=-2116/360, 2-19=-2115/354,3-19=-2042/384, 3-20=-2257/407, 20-21=-2258/407, 4-21=-2260/407, 4-5=-2257/406, 5-6=-2257/406, 6-22=-1651/313, 7-22=-1651/313, 7-8=-1752/334, 1-15=-1403/269 BOT CHORD 14-15=-385/409, 13-14=-588/1961, 12-13=-473/1866, 11-12=-473/1866, 10-11=-332/1651, 9-10=-332/1651 WEBS 2-13=-518/197, 3-13=-25/432, 3-11=-166/532, 4-11=-745/245, 6-11=-178/813, 6-9=-1286/351, 7-9=-361/2180, 1-14=-205/1750 NOTES- 1) Unbalancedroofliveloads have been considered for this design. 2)Wind:ASCE 7-10;Vult=115mph(3-second gust)Vasd=91mph;TCDL=6.0psf;BCDL=6.0psf; h=25ft; Cat. II;Exp C; enclosed; MWFRS(envelope) gable end zone and C-CExterior(2) 0-1-12 to 3-9-12,Interior(1) 3-9-12 to 12-10-14,Exterior(2) 12-10-14 to 18-1-2zone;cantileverleft and right exposed ; end verticalleft and right exposed;C-C formembers and forces&MWFRS for reactionsshown; Lumber DOL=1.60 plate grip DOL=1.60 3)TCLL:ASCE 7-10;Pr=20.0 psf(roofliveload: Lumber DOL=1.15Plate DOL=1.15);Pg=20.0 psf(groundsnow);Pf=20.4 psf(flat roofsnow: Lumber DOL=1.15Plate DOL=1.15); CategoryII;Exp C; PartiallyExp.; Ct=1.1, Lu=50-0-0;Min. flatroofsnowload governs. Rainsurcharge applied to all exposedsurfaceswithslopesless than 0.500/12 in accordancewithIBC 1608.3.4.4) Unbalancedsnowloads have been considered for this design. 5)Provide adequate drainage to preventwater ponding. 6)This truss has been designed for a 10.0 psf bottomchordliveload nonconcurrentwith any otherliveloads.7)Providemechanicalconnection(by others) of truss to bearing platecapable of withstanding 100 lb uplift at joint(s) except(jt=lb) 8=299, 15=156. 8)This trussis designedin accordancewith the 2012 InternationalBuilding Code section 2306.1 and referencedstandardANSI/TPI 1. LOADCASE(S)Standard DE Job # 59223-W1 Dansco Engineering, LLC Date: 6/13/18 WARNING – VERIFY DESIGN PARAMETERS AND READ NOTES BEFORE FABRICATION AND INSTALLATION!!! This truss design is adequate for the design parameters shown. Review and approval of design parameters is the responsibility of the building designer, not the truss designer or truss engineer. Permanent bracing requirements against out-of-plane buckling are noted/shown for individual truss members (and for the truss as a whole) subjected to gravity and wind loads. Additional permanent bracing design shall be the responsibility of the design professional of record. Temporary and erection bracing shall be the responsibility of the contractor. Reference ANSI/TPI-1, “National Design Standard for Metal Plate Connected Wood Truss Construction” and TPI/WTCA BCSI-06, “Building Component Safety Information Guide to Good Practice for Handling, Installing, Restraining and Bracing of Metal Plate Connected Wood Trusses” for additional information. Job 1802242-12T Truss T20 TrussType HalfHip Qty 1 Ply 1 1802242-12TDWHWoodside-West Clay- 4 Job Reference (optional)Run:8.200 s Apr72018 Print:8.200 s Apr72018MiTekIndustries,Inc.Tue Jun1221:12:102018 Page1ID:bRTO9oDnRLEHvJjVgeMKW3yF_s1-NddzrERIBsD7A_9SuqX86StJs59EZmn3rSMJqKz6wGJ Scale=1:69.0 0 -1 -14 T2 T3 W7 B1 W3 W4 W5 W6 W7 W6 W7 W6 W1 W2 T1 T4 B3B2 1 2 3 4 5 6 7 8 16 15 14 13 12 11 10 9 17 18 19 20 21 22 3x6 6x6 3x6 5x6 3x44x43x6 3x4 4x6 3x4 1.5x4 4x8 3x4 5x6 4x6 3x6 8-1-3 8-1-3 15-10-14 7-9-11 22-8-3 6-9-5 29-7-3 6-11-1 36-8-0 7-0-13 8-1-3 8-1-3 15-10-14 7-9-11 22-8-3 6-9-5 29-7-3 6-11-1 36-8-0 7-0-13 1 -1 -0 8 -10 -9 9 -0 -7 8 -10 -9 6.0012 PlateOffsets(X,Y)-- [1:0-3-0,0-1-8], [9:Edge,0-1-8] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 10.0 SPACING- PlateGrip DOL Lumber DOL RepStressIncr Code 2-0-0 1.15 1.15 YES IBC2012/TPI2007 CSI. TC BC WB Matrix-MSH 0.98 0.67 0.67 DEFL. Vert(LL) Vert(TL) Horz(TL) in -0.11 -0.31 0.07 (loc) 15-16 13-15 9 l/defl >999 >999 n/a L/d 240 180 n/a PLATES MT20 Weight: 185 lb FT= 20% GRIP 197/144 LUMBER- TOP CHORD2x4SPF No.2 *Except*T2: 2x4SPF 1650F 1.5E BOT CHORD2x4SPF No.2 WEBS 2x4SPF No.2 *Except*W3,W1: 2x4SPFStud BRACING- TOP CHORD Structuralwoodsheathing directly applied, except end verticals.BOT CHORD Rigidceiling directly applied or 7-6-2 oc bracing. WEBS 1 Row at midpt 8-9, 3-13, 4-11, 5-11, 7-10 MiTekrecommends that Stabilizers and requiredcross bracing beinstalled during truss erection,in accordancewithStabilizerInstallation guide. REACTIONS.(lb/size)9=1435/0-6-0(min. 0-2-12), 16=1346/0-6-0(min. 0-2-5) Max Horz16=354(LC 13)Max Uplift9=-294(LC 13), 16=-182(LC 16) MaxGrav9=1755(LC 34), 16=1476(LC 35) FORCES.(lb)-Max. Comp./Max.Ten.-All forces 250 (lb) orless exceptwhenshown. TOP CHORD 1-17=-2364/326, 17-18=-2278/328, 2-18=-2273/330, 2-3=-2149/351, 3-19=-1826/330, 19-20=-1797/332, 4-20=-1751/367, 4-21=-1682/367, 5-21=-1685/367, 5-6=-1682/366,6-7=-1682/366, 7-22=-1172/285, 8-22=-1172/285, 8-9=-1693/323, 1-16=-1398/269 BOT CHORD 15-16=-466/509, 14-15=-608/2038, 13-14=-608/2038, 12-13=-459/1568, 11-12=-459/1568, 10-11=-275/1172 WEBS 3-13=-735/251, 4-13=-49/539, 4-11=-328/217, 5-11=-646/215, 7-11=-197/813, 7-10=-1287/350, 8-10=-317/1843, 1-15=-144/1769 NOTES- 1) Unbalancedroofliveloads have been considered for this design. 2)Wind:ASCE 7-10;Vult=115mph(3-second gust)Vasd=91mph;TCDL=6.0psf;BCDL=6.0psf; h=25ft; Cat. II;Exp C; enclosed; MWFRS(envelope) gable end zone and C-CExterior(2) 0-1-12 to 3-9-12,Interior(1) 3-9-12 to 15-10-14,Exterior(2) 15-10-14 to 21-1-2zone;cantileverleft and right exposed ; end verticalleft and right exposed;C-C formembers and forces&MWFRS for reactionsshown; Lumber DOL=1.60 plate grip DOL=1.60 3)TCLL:ASCE 7-10;Pr=20.0 psf(roofliveload: Lumber DOL=1.15Plate DOL=1.15);Pg=20.0 psf(groundsnow);Pf=20.4 psf(flat roofsnow: Lumber DOL=1.15Plate DOL=1.15); CategoryII;Exp C; PartiallyExp.; Ct=1.1, Lu=50-0-0;Min. flatroofsnowload governs. Rainsurcharge applied to all exposedsurfaceswithslopesless than 0.500/12 in accordancewithIBC 1608.3.4. 4) Unbalancedsnowloads have been considered for this design.5)Provide adequate drainage to preventwater ponding. 6)This truss has been designed for a 10.0 psf bottomchordliveload nonconcurrentwith any otherliveloads. 7)Providemechanicalconnection(by others) of truss to bearing platecapable of withstanding 100 lb uplift at joint(s) except(jt=lb)9=294, 16=182. 8)This trussis designedin accordancewith the 2012 InternationalBuilding Code section 2306.1 and referencedstandardANSI/TPI 1. LOADCASE(S)Standard DE Job # 59223-W1 Dansco Engineering, LLC Date: 6/13/18 WARNING – VERIFY DESIGN PARAMETERS AND READ NOTES BEFORE FABRICATION AND INSTALLATION!!! This truss design is adequate for the design parameters shown. Review and approval of design parameters is the responsibility of the building designer, not the truss designer or truss engineer. Permanent bracing requirements against out-of-plane buckling are noted/shown for individual truss members (and for the truss as a whole) subjected to gravity and wind loads. Additional permanent bracing design shall be the responsibility of the design professional of record. Temporary and erection bracing shall be the responsibility of the contractor. Reference ANSI/TPI-1, “National Design Standard for Metal Plate Connected Wood Truss Construction” and TPI/WTCA BCSI-06, “Building Component Safety Information Guide to Good Practice for Handling, Installing, Restraining and Bracing of Metal Plate Connected Wood Trusses” for additional information. Job 1802242-12T Truss T21 TrussType Hip Qty 1 Ply 1 1802242-12TDWHWoodside-West Clay- 4 Job Reference (optional)Run:8.200 s Apr72018 Print:8.200 s Apr72018MiTekIndustries,Inc.Tue Jun1221:12:122018 Page1ID:bRTO9oDnRLEHvJjVgeMKW3yF_s1-K0ljGwTZjTTrQIJr0EacBtyi2usK1eGMJmrQuDz6wGH Scale=1:74.8 0 -1 -14 0 -1 -14 T2 T3 T5 B1 W3 W4 W5 W6 W7 W8 W9 W8 W9 W8 W7 W1 W2 W11 W10 T1 T4 B1B2 1 2 3 4 5 6 7 8 9 10 20 19 18 17 16 15 14 13 12 11 21 22 23 24 3x6 6x6 3x6 5x6 3x4 3x6 3x4 6x6 3x4 3x4 3x4 3x4 3x4 1.5x4 6x8 6x6 4x6 5x6 4x4 3x6 6-5-15 6-5-15 12-8-7 6-2-7 18-10-14 6-2-7 24-2-6 5-3-8 29-7-10 5-5-4 34-11-2 5-3-8 36-8-0 1-8-14 6-5-15 6-5-15 12-8-7 6-2-7 18-10-14 6-2-7 24-2-6 5-3-8 29-7-10 5-5-4 34-11-2 5-3-8 36-8-0 1-8-14 1 -1 -0 10 -4 -9 10 -6 -7 9 -8 -0 10 -4 -9 6.0012 PlateOffsets(X,Y)-- [10:Edge,0-1-12], [11:Edge,0-3-8] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 10.0 SPACING- PlateGrip DOL Lumber DOL RepStressIncr Code 2-0-0 1.15 1.15 YES IBC2012/TPI2007 CSI. TC BC WB Matrix-MSH 0.81 0.57 0.80 DEFL. Vert(LL) Vert(TL) Horz(TL) in -0.11 -0.29 0.08 (loc) 18 16-18 11 l/defl >999 >999 n/a L/d 240 180 n/a PLATES MT20 Weight: 229 lb FT= 20% GRIP 197/144 LUMBER- TOP CHORD2x4SPF No.2BOT CHORD2x4SPF No.2 WEBS 2x4SPF No.2 *Except* W3,W5,W1,W2: 2x4SPFStud BRACING- TOP CHORD Structuralwoodsheathing directly applied or 3-2-7 oc purlins,except end verticals. BOT CHORD Rigidceiling directly applied or 7-6-12 oc bracing. WEBS 1 Row at midpt 4-16, 5-14, 6-13, 8-13, 9-12, 10-11 MiTekrecommends that Stabilizers and requiredcross bracingbeinstalled during truss erection,in accordancewithStabilizer Installation guide. REACTIONS.(lb/size)20=1330/0-6-0(min. 0-2-5), 11=1406/0-6-0(min. 0-2-8)Max Horz20=399(LC 13) Max Uplift20=-202(LC 16), 11=-238(LC 13) MaxGrav20=1476(LC 38), 11=1582(LC 37) FORCES.(lb)-Max. Comp./Max.Ten.-All forces 250 (lb) orless exceptwhenshown. TOP CHORD 1-21=-2345/314, 2-21=-2261/319, 2-3=-2215/333, 3-22=-2108/330, 4-22=-1900/360,4-23=-1563/335, 5-23=-1473/364, 5-6=-1260/349, 6-24=-912/292, 7-24=-912/292, 7-8=-912/292, 8-9=-915/293, 9-10=-313/240, 1-20=-1410/254, 10-11=-1528/332 BOT CHORD 19-20=-500/490, 18-19=-609/2039, 17-18=-537/1794, 16-17=-537/1794, 15-16=-419/1316, 14-15=-419/1316, 13-14=-361/1257, 12-13=-135/257 WEBS 3-18=-293/160, 4-18=-15/364, 4-16=-800/247, 5-16=-118/725, 5-14=-462/127, 6-14=-50/512, 6-13=-775/191, 8-13=-512/167, 9-13=-292/1443, 9-12=-1430/429, 1-19=-160/1859, 10-12=-277/1453 NOTES- 1) Unbalancedroofliveloads have been considered for this design. 2)Wind:ASCE 7-10;Vult=115mph(3-second gust)Vasd=91mph;TCDL=6.0psf;BCDL=6.0psf; h=25ft; Cat. II;Exp C; enclosed; MWFRS(envelope) gable end zone and C-CExterior(2) 0-1-12 to 3-9-12,Interior(1) 3-9-12 to 18-10-14,Exterior(2) 18-10-14 to 36-6-4zone;cantileverleft and right exposed ; end verticalleft and right exposed;C-C formembers and forces&MWFRS for reactionsshown; Lumber DOL=1.60 plate grip DOL=1.60 3)TCLL:ASCE 7-10;Pr=20.0 psf(roofliveload: Lumber DOL=1.15Plate DOL=1.15);Pg=20.0 psf(groundsnow);Pf=20.4 psf(flat roofsnow: Lumber DOL=1.15Plate DOL=1.15); CategoryII;Exp C; PartiallyExp.; Ct=1.1, Lu=50-0-0;Min. flatroofsnowloadgoverns. Rainsurcharge applied to all exposedsurfaceswithslopesless than 0.500/12 in accordancewithIBC 1608.3.4. 4) Unbalancedsnowloads have been considered for this design. 5)Provide adequate drainage to preventwater ponding.6)This truss has been designed for a 10.0 psf bottomchordliveload nonconcurrentwith any otherliveloads. 7)Providemechanicalconnection(by others) of truss to bearing platecapable of withstanding 100 lb uplift at joint(s) except(jt=lb) 20=202, 11=238.8)This trussis designedin accordancewith the 2012 InternationalBuilding Code section 2306.1 and referencedstandardANSI/TPI 1. LOADCASE(S)Standard DE Job # 59223-W1 Dansco Engineering, LLC Date: 6/13/18 WARNING – VERIFY DESIGN PARAMETERS AND READ NOTES BEFORE FABRICATION AND INSTALLATION!!! This truss design is adequate for the design parameters shown. Review and approval of design parameters is the responsibility of the building designer, not the truss designer or truss engineer. Permanent bracing requirements against out-of-plane buckling are noted/shown for individual truss members (and for the truss as a whole) subjected to gravity and wind loads. Additional permanent bracing design shall be the responsibility of the design professional of record. Temporary and erection bracing shall be the responsibility of the contractor. Reference ANSI/TPI-1, “National Design Standard for Metal Plate Connected Wood Truss Construction” and TPI/WTCA BCSI-06, “Building Component Safety Information Guide to Good Practice for Handling, Installing, Restraining and Bracing of Metal Plate Connected Wood Trusses” for additional information. Job 1802242-12T Truss T22 TrussType Hip Qty 1 Ply 1 1802242-12TDWHWoodside-West Clay- 4 Job Reference (optional)Run:8.200 s Apr72018 Print:8.200 s Apr72018MiTekIndustries,Inc.Tue Jun1221:12:132018 Page1ID:bRTO9oDnRLEHvJjVgeMKW3yF_s1-oCJ5TGUBUnbi1Ru1Zy5rj4VrKIBpm7cVXQbzQfz6wGG Scale=1:80.1 0 -1 -14 0 -1 -14 T2 T3 T4 B1 W3 W4 W5 W6 W7 W8 W9 W8 W7 W1 W2 W11 W10 T1 B3B2 1 2 3 4 5 6 7 8 17 16 15 14 13 12 11 10 9 18 19 20 21 22 23 3x6 6x6 6x6 4x4 3x6 3x4 5x6 3x4 3x4 3x5 1.5x4 5x8 4x6 4x6 3x4 5x6 3x6 7-5-15 7-5-15 14-8-7 7-2-7 21-10-14 7-2-7 26-11-0 5-0-2 31-11-2 5-0-2 36-8-0 4-8-14 7-5-15 7-5-15 14-8-7 7-2-7 21-10-14 7-2-7 26-11-0 5-0-2 31-11-2 5-0-2 36-8-0 4-8-14 1 -1 -0 11 -10 -9 12 -0 -7 9 -8 -0 11 -10 -9 6.0012 PlateOffsets(X,Y)-- [1:0-3-0,0-1-8], [8:Edge,0-1-12], [9:Edge,0-1-8] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 10.0 SPACING- PlateGrip DOL Lumber DOL RepStressIncr Code 2-0-0 1.15 1.15 YES IBC2012/TPI2007 CSI. TC BC WB Matrix-MSH 0.84 0.61 0.67 DEFL. Vert(LL) Vert(TL) Horz(TL) in -0.12 -0.32 0.08 (loc) 15-16 13-15 9 l/defl >999 >999 n/a L/d 240 180 n/a PLATES MT20 Weight: 220 lb FT= 20% GRIP 197/144 LUMBER- TOP CHORD2x4SPF No.2BOT CHORD2x4SPF No.2 WEBS 2x4SPF No.2 *Except* W3,W1: 2x4SPFStud BRACING- TOP CHORD Structuralwoodsheathing directly applied, except end verticals.BOT CHORD Rigidceiling directly applied or 7-8-6 oc bracing. WEBS 1 Row at midpt 2-15, 4-13, 5-11, 6-11, 7-10, 8-9 MiTekrecommends that Stabilizers and requiredcross bracing beinstalled during truss erection,in accordancewithStabilizerInstallation guide. REACTIONS.(lb/size)17=1314/0-6-0(min. 0-2-5), 9=1361/0-6-0(min. 0-2-5) Max Horz17=418(LC 13)Max Uplift17=-218(LC 16), 9=-138(LC 13) MaxGrav17=1484(LC 38), 9=1475(LC 38) FORCES.(lb)-Max. Comp./Max.Ten.-All forces 250 (lb) orless exceptwhenshown. TOP CHORD 1-18=-2382/320, 2-18=-2299/342, 2-3=-2054/326, 3-19=-1994/336, 4-19=-1844/361, 4-20=-1428/329, 5-20=-1272/363, 5-6=-904/344, 6-21=-904/343, 21-22=-902/343,7-22=-901/344, 7-23=-514/290, 8-23=-620/268, 1-17=-1411/261, 8-9=-1435/342 BOT CHORD 16-17=-497/523, 15-16=-583/2063, 14-15=-491/1752, 13-14=-491/1752, 12-13=-356/1132, 11-12=-356/1132, 10-11=-204/511 WEBS 2-15=-421/195, 4-15=-18/458, 4-13=-930/289, 5-13=-144/825, 5-11=-681/164, 6-11=-521/173, 7-11=-235/1009, 7-10=-943/334, 1-16=-154/1836, 8-10=-272/1158 NOTES- 1) Unbalancedroofliveloads have been considered for this design. 2)Wind:ASCE 7-10;Vult=115mph(3-second gust)Vasd=91mph;TCDL=6.0psf;BCDL=6.0psf; h=25ft; Cat. II;Exp C; enclosed; MWFRS(envelope) gable end zone and C-CExterior(2) 0-1-12 to 3-9-12,Interior(1) 3-9-12 to 21-10-14,Exterior(2) 21-10-14 to 36-6-4zone;cantileverleft and right exposed ; end verticalleft and right exposed;C-C formembers and forces&MWFRS for reactionsshown; Lumber DOL=1.60 plate grip DOL=1.60 3)TCLL:ASCE 7-10;Pr=20.0 psf(roofliveload: Lumber DOL=1.15Plate DOL=1.15);Pg=20.0 psf(groundsnow);Pf=20.4 psf(flat roofsnow: Lumber DOL=1.15Plate DOL=1.15); CategoryII;Exp C; PartiallyExp.; Ct=1.1, Lu=50-0-0;Min. flatroofsnowload governs. Rainsurcharge applied to all exposedsurfaceswithslopesless than 0.500/12 in accordancewithIBC 1608.3.4. 4) Unbalancedsnowloads have been considered for this design.5)Provide adequate drainage to preventwater ponding. 6)This truss has been designed for a 10.0 psf bottomchordliveload nonconcurrentwith any otherliveloads. 7)Providemechanicalconnection(by others) of truss to bearing platecapable of withstanding 100 lb uplift at joint(s) except(jt=lb)17=218, 9=138. 8)This trussis designedin accordancewith the 2012 InternationalBuilding Code section 2306.1 and referencedstandardANSI/TPI 1. LOADCASE(S)Standard DE Job # 59223-W1 Dansco Engineering, LLC Date: 6/13/18 WARNING – VERIFY DESIGN PARAMETERS AND READ NOTES BEFORE FABRICATION AND INSTALLATION!!! This truss design is adequate for the design parameters shown. Review and approval of design parameters is the responsibility of the building designer, not the truss designer or truss engineer. Permanent bracing requirements against out-of-plane buckling are noted/shown for individual truss members (and for the truss as a whole) subjected to gravity and wind loads. Additional permanent bracing design shall be the responsibility of the design professional of record. Temporary and erection bracing shall be the responsibility of the contractor. Reference ANSI/TPI-1, “National Design Standard for Metal Plate Connected Wood Truss Construction” and TPI/WTCA BCSI-06, “Building Component Safety Information Guide to Good Practice for Handling, Installing, Restraining and Bracing of Metal Plate Connected Wood Trusses” for additional information. Job 1802242-12T Truss T23 TrussType PiggybackBase Qty 1 Ply 1 1802242-12TDWHWoodside-West Clay- 4 Job Reference (optional)Run:8.200 s Apr72018 Print:8.200 s Apr72018MiTekIndustries,Inc.Tue Jun1221:12:142018 Page1ID:bRTO9oDnRLEHvJjVgeMKW3yF_s1-GPsUhcVpF4jZfbTD7fc4GI11FiXLVYuem4KWz5z6wGF Scale=1:74.1 T2 T3 T4 B1 W3 W4 W5 W6 W7 W8 W9 W8 W7 W1 W2 W11 W10 T1 B3B2 1 2 3 4 5 6 7 8 17 16 15 14 13 12 11 10 9 18 19 20 21 22 3x6 5x6 4x4 3x6 3x4 6x6 3x4 3x4 3x5 5x6 1.5x4 5x8 5x6 6x6 3x4 5x6 3x6 7-1-11 7-1-11 13-11-13 6-10-3 20-10-0 6-10-3 26-11-0 6-1-0 33-0-0 6-1-0 36-8-0 3-8-0 7-1-11 7-1-11 13-11-13 6-10-3 20-10-0 6-10-3 26-11-0 6-1-0 33-0-0 6-1-0 36-8-0 3-8-0 1 -1 -0 11 -6 -0 9 -8 -0 11 -6 -0 6.0012 PlateOffsets(X,Y)-- [5:0-3-0,0-2-0], [7:0-3-0,0-2-0], [8:Edge,0-1-12], [9:Edge,0-1-8] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 10.0 SPACING- PlateGrip DOL Lumber DOL RepStressIncr Code 2-0-0 1.15 1.15 YES IBC2012/TPI2007 CSI. TC BC WB Matrix-MSH 0.83 0.60 0.79 DEFL. Vert(LL) Vert(TL) Horz(TL) in -0.11 -0.30 0.08 (loc) 15-16 13-15 9 l/defl >999 >999 n/a L/d 240 180 n/a PLATES MT20 Weight: 216 lb FT= 20% GRIP 197/144 LUMBER- TOP CHORD2x4SPF No.2BOT CHORD2x4SPF No.2 WEBS 2x4SPF No.2 *Except* W3,W1,W2: 2x4SPFStud BRACING- TOP CHORD Structuralwoodsheathing directly applied or 2-2-0 oc purlins,except end verticals. BOT CHORD Rigidceiling directly applied or 7-7-12 oc bracing. WEBS 1 Row at midpt 4-13, 5-11, 6-11, 7-10, 8-9 MiTekrecommends that Stabilizers and requiredcross bracingbeinstalled during truss erection,in accordancewithStabilizer Installation guide. REACTIONS.(lb/size)17=1320/0-6-0(min. 0-2-5), 9=1377/0-6-0(min. 0-2-5)Max Horz17=412(LC 13) Max Uplift17=-212(LC 16), 9=-174(LC 13) MaxGrav17=1481(LC 38), 9=1455(LC 2) FORCES.(lb)-Max. Comp./Max.Ten.-All forces 250 (lb) orless exceptwhenshown. TOP CHORD 1-18=-2369/315, 2-18=-2286/318, 2-3=-2226/336, 3-19=-2074/327, 4-19=-1864/360,4-20=-1474/331, 5-20=-1323/364, 5-21=-952/338, 6-21=-952/338, 6-22=-952/338, 7-22=-952/338, 7-8=-499/275, 1-17=-1409/258, 8-9=-1431/330 BOT CHORD 16-17=-494/514, 15-16=-591/2055, 14-15=-508/1768, 13-14=-508/1768, 12-13=-376/1173, 11-12=-376/1173, 10-11=-186/429 WEBS 3-15=-374/181, 4-15=-17/422, 4-13=-900/279, 5-13=-135/809, 5-11=-648/157, 6-11=-617/207, 7-11=-253/1102, 7-10=-1051/366, 1-16=-154/1840, 8-10=-289/1226 NOTES- 1) Unbalancedroofliveloads have been considered for this design. 2)Wind:ASCE 7-10;Vult=115mph(3-second gust)Vasd=91mph;TCDL=6.0psf;BCDL=6.0psf; h=25ft; Cat. II;Exp C; enclosed; MWFRS(envelope) gable end zone and C-CExterior(2) 0-1-12 to 3-9-12,Interior(1) 3-9-12 to 20-10-0,Exterior(2) 20-10-0 to 36-6-4 zone;cantileverleft and right exposed ; end verticalleft and right exposed;C-C formembers and forces&MWFRS forreactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3)TCLL:ASCE 7-10;Pr=20.0 psf(roofliveload: Lumber DOL=1.15Plate DOL=1.15);Pg=20.0 psf(groundsnow);Pf=20.4 psf(flat roofsnow: Lumber DOL=1.15Plate DOL=1.15); CategoryII;Exp C; PartiallyExp.; Ct=1.1, Lu=50-0-0;Min. flatroofsnowload governs. Rainsurcharge applied to all exposedsurfaceswithslopesless than 0.500/12 in accordancewithIBC 1608.3.4.4) Unbalancedsnowloads have been considered for this design. 5)Provide adequate drainage to preventwater ponding. 6)This truss has been designed for a 10.0 psf bottomchordliveload nonconcurrentwith any otherliveloads.7)Providemechanicalconnection(by others) of truss to bearing platecapable of withstanding 100 lb uplift at joint(s) except(jt=lb) 17=212, 9=174. 8)This trussis designedin accordancewith the 2012 InternationalBuilding Code section 2306.1 and referencedstandardANSI/TPI 1. LOADCASE(S)Standard DE Job # 59223-W1 Dansco Engineering, LLC Date: 6/13/18 WARNING – VERIFY DESIGN PARAMETERS AND READ NOTES BEFORE FABRICATION AND INSTALLATION!!! This truss design is adequate for the design parameters shown. Review and approval of design parameters is the responsibility of the building designer, not the truss designer or truss engineer. Permanent bracing requirements against out-of-plane buckling are noted/shown for individual truss members (and for the truss as a whole) subjected to gravity and wind loads. Additional permanent bracing design shall be the responsibility of the design professional of record. Temporary and erection bracing shall be the responsibility of the contractor. Reference ANSI/TPI-1, “National Design Standard for Metal Plate Connected Wood Truss Construction” and TPI/WTCA BCSI-06, “Building Component Safety Information Guide to Good Practice for Handling, Installing, Restraining and Bracing of Metal Plate Connected Wood Trusses” for additional information. Job 1802242-12T Truss T24 TrussType PiggybackBase Qty 4 Ply 1 1802242-12TDWHWoodside-West Clay- 4 Job Reference (optional)Run:8.200 s Apr72018 Print:8.200 s Apr72018MiTekIndustries,Inc.Tue Jun1221:12:162018 Page1ID:bRTO9oDnRLEHvJjVgeMKW3yF_s1-Cn_E5HW3nizGuvdcF4eYLj7NlV88zRsxDOpd1_z6wGD Scale=1:82.1 T2 T3 T4 B1 B2 B3 B4 B5 W3 W5 W4 W6 W7 W8 W10 W9 W11 W12 W13 W12 W11 W1 W2 W15 W14T1 B6 12 3 4 5 6 7 8 9 10 2221 20 19 18 17 16 15 14 13 12 11 23 24 25 26 27 3x6 5x6 3x4 4x8 6x8 2x4 2x4 3x6 8x8 4x4 4x6 5x12 4x4 3x4 4x4 5x10 1.5x4 5x8 5x6 4x6 3x4 5x6 1-0-01-0-02-6-01-6-0 8-8-06-2-0 14-10-06-2-0 20-10-06-0-0 26-11-06-1-0 33-0-06-1-0 36-8-03-8-0 1-0-01-0-02-6-01-6-0 8-8-06-2-0 14-10-06-2-0 20-10-06-0-0 26-11-06-1-0 33-0-06-1-0 36-8-03-8-0 1 -1 -0 11 -6 -0 9 -8 -0 1 -0 -0 11 -6 -0 6.0012 PlateOffsets(X,Y)-- [7:0-7-4,0-2-8], [9:0-3-0,0-2-0], [10:Edge,0-1-12], [11:Edge,0-1-8], [17:0-2-12,0-3-0] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 10.0 SPACING- PlateGrip DOL Lumber DOL RepStressIncr Code 2-0-0 1.15 1.15 YES IBC2012/TPI2007 CSI. TC BC WB Matrix-MSH 0.83 0.96 0.89 DEFL. Vert(LL) Vert(TL) Horz(TL) in -0.17 -0.44 0.24 (loc) 6 17-18 11 l/defl >999 >999 n/a L/d 240 180 n/a PLATES MT20 Weight: 230 lb FT= 20% GRIP 197/144 LUMBER- TOP CHORD2x4SPF No.2BOT CHORD2x4SPF No.2 *Except* B2: 2x4SPFStud WEBS 2x4SPF No.2 *Except*W3,W5,W6,W7,W10,W1,W2: 2x4SPFStud BRACING- TOP CHORD Structuralwoodsheathing directly applied or 3-0-9 oc purlins,except end verticals. BOT CHORD Rigidceiling directly applied or 2-2-0 oc bracing. WEBS 1 Row at midpt 7-15, 7-13, 8-13, 9-12, 10-11 MiTekrecommends that Stabilizers and requiredcross bracingbeinstalled during truss erection,in accordancewithStabilizer Installation guide. REACTIONS.(lb/size)22=1320/0-6-0(min. 0-2-5), 11=1377/0-6-0(min. 0-2-5)Max Horz22=412(LC 13) Max Uplift22=-212(LC 16), 11=-174(LC 13) MaxGrav22=1481(LC 38), 11=1455(LC 2) FORCES.(lb)-Max. Comp./Max.Ten.-All forces 250 (lb) orless exceptwhenshown. TOP CHORD 1-2=-1029/152, 2-3=-3304/746, 3-23=-2881/411, 4-23=-2752/437, 4-24=-2244/341,5-24=-2235/345, 5-6=-2031/375, 6-25=-2254/472, 7-25=-2122/500, 7-26=-952/338, 8-26=-952/338, 8-27=-952/338, 9-27=-952/338, 9-10=-499/275, 1-22=-1333/206, 10-11=-1431/330 BOT CHORD 21-22=-469/400, 20-21=-505/892, 19-20=-401/734, 3-19=-137/251, 18-19=-1190/3216, 17-18=-712/2525, 6-17=-577/253, 14-15=-375/1172, 13-14=-375/1172, 12-13=-186/429 WEBS 2-21=-990/161, 2-20=-899/523, 2-19=-994/2739, 3-18=-810/483, 4-18=0/389, 4-17=-736/242, 15-17=-358/1112, 7-17=-381/1465, 7-13=-642/154, 8-13=-618/207, 9-13=-254/1103, 9-12=-1050/365, 1-21=-148/1087, 10-12=-289/1226 NOTES- 1) Unbalancedroofliveloads have been considered for this design. 2)Wind:ASCE 7-10;Vult=115mph(3-second gust)Vasd=91mph;TCDL=6.0psf;BCDL=6.0psf; h=25ft; Cat. II;Exp C; enclosed; MWFRS(envelope) gable end zone and C-CExterior(2) 0-1-12 to 3-9-12,Interior(1) 3-9-12 to 20-10-0,Exterior(2) 20-10-0 to 36-6-4 zone;cantileverleft and right exposed ; end verticalleft and right exposed;C-C formembers and forces&MWFRS forreactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3)TCLL:ASCE 7-10;Pr=20.0 psf(roofliveload: Lumber DOL=1.15Plate DOL=1.15);Pg=20.0 psf(groundsnow);Pf=20.4 psf(flatroofsnow: Lumber DOL=1.15Plate DOL=1.15); CategoryII;Exp C; PartiallyExp.; Ct=1.1, Lu=50-0-0;Min. flatroofsnowload governs. Rainsurcharge applied to all exposedsurfaceswithslopesless than 0.500/12 in accordancewithIBC 1608.3.4. 4) Unbalancedsnowloads have been considered for this design.5)Provide adequate drainage to preventwater ponding. 6)This truss has been designed for a 10.0 psf bottomchordliveload nonconcurrentwith any otherliveloads. 7)Providemechanicalconnection(by others) of truss to bearing platecapable of withstanding 100 lb uplift at joint(s) except(jt=lb)22=212, 11=174. 8)This trussis designedin accordancewith the 2012 InternationalBuilding Code section 2306.1 and referencedstandardANSI/TPI 1. LOADCASE(S)Standard DE Job # 59223-W1 Dansco Engineering, LLC Date: 6/13/18 WARNING – VERIFY DESIGN PARAMETERS AND READ NOTES BEFORE FABRICATION AND INSTALLATION!!! This truss design is adequate for the design parameters shown. Review and approval of design parameters is the responsibility of the building designer, not the truss designer or truss engineer. Permanent bracing requirements against out-of-plane buckling are noted/shown for individual truss members (and for the truss as a whole) subjected to gravity and wind loads. Additional permanent bracing design shall be the responsibility of the design professional of record. Temporary and erection bracing shall be the responsibility of the contractor. Reference ANSI/TPI-1, “National Design Standard for Metal Plate Connected Wood Truss Construction” and TPI/WTCA BCSI-06, “Building Component Safety Information Guide to Good Practice for Handling, Installing, Restraining and Bracing of Metal Plate Connected Wood Trusses” for additional information. Job 1802242-12T Truss T25 TrussType PiggybackBase Qty 2 Ply 1 1802242-12TDWHWoodside-West Clay- 4 Job Reference (optional)Run:8.200 s Apr72018 Print:8.200 s Apr72018MiTekIndustries,Inc.Tue Jun1221:12:172018 Page1ID:bRTO9oDnRLEHvJjVgeMKW3yF_s1-g_YcJdXhY?57W3Booo9nuwfWavTmiu85S2ZBaQz6wGC Scale=1:79.9 T2 T3 T4 B1 B2 B3 B4 B5 W3 W5 W4 W6 W7 W8 W10 W9 W11 W12 W13 W12 W11 W1 W2 W15 W14 T1 B6 12 3 4 5 6 7 8 9 10 2221 20 19 18 17 16 15 14 13 12 11 23 24 25 26 2728 3x6 5x6 5x6 3x4 4x8 6x8 2x4 2x4 3x6 8x8 4x4 4x6 5x12 4x4 3x4 4x4 5x10 1.5x4 5x8 4x6 4x6 4x4 1-0-01-0-02-6-01-6-0 8-8-06-2-0 14-10-06-2-0 20-10-06-0-0 26-11-06-1-0 33-0-06-1-0 35-8-02-8-0 1-0-0 1-0-0 2-6-0 1-6-0 8-8-0 6-2-0 14-10-0 6-2-0 20-10-0 6-0-0 26-11-0 6-1-0 33-0-0 6-1-0 35-8-0 2-8-0 1 -1 -0 11 -6 -0 10 -2 -0 1 -0 -0 11 -6 -0 6.0012 PlateOffsets(X,Y)-- [7:0-7-4,0-2-8], [9:0-3-0,0-2-0], [10:Edge,0-1-12], [11:Edge,0-3-8], [17:0-2-12,0-3-0] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 10.0 SPACING- PlateGrip DOL Lumber DOL RepStressIncr Code 2-0-0 1.15 1.15 YES IBC2012/TPI2007 CSI. TC BC WB Matrix-MSH 0.95 0.93 0.89 DEFL. Vert(LL) Vert(TL) Horz(TL) in -0.16 -0.42 0.23 (loc) 6 17-18 11 l/defl >999 >999 n/a L/d 240 180 n/a PLATES MT20 Weight: 228 lb FT= 20% GRIP 197/144 LUMBER- TOP CHORD2x4SPF No.2BOT CHORD2x4SPF No.2 *Except* B2: 2x4SPFStud WEBS 2x4SPF No.2 *Except*W3,W5,W6,W7,W10,W1,W2: 2x4SPFStud BRACING- TOP CHORD Structuralwoodsheathing directly applied or 3-1-3 oc purlins,except end verticals. BOT CHORD Rigidceiling directly applied or 2-2-0 oc bracing. WEBS 1 Row at midpt 7-14, 7-13, 8-13, 9-12, 10-11 MiTekrecommends that Stabilizers and requiredcross bracingbeinstalled during truss erection,in accordancewithStabilizer Installation guide. REACTIONS.(lb/size)22=1282/0-6-0(min. 0-2-4), 11=1344/0-6-0(min. 0-2-4)Max Horz22=427(LC 13) Max Uplift22=-208(LC 16), 11=-195(LC 13) MaxGrav22=1443(LC 38), 11=1415(LC 2) FORCES.(lb)-Max. Comp./Max.Ten.-All forces 250 (lb) orless exceptwhenshown. TOP CHORD 1-2=-1002/146, 2-3=-3216/730, 3-23=-2793/402, 4-23=-2664/428, 4-24=-2158/323,5-24=-2149/326, 5-6=-1945/356, 6-25=-2168/463, 7-25=-2036/492, 7-26=-858/319, 8-26=-858/319, 8-27=-858/319, 27-28=-858/319, 9-28=-858/319, 9-10=-403/267, 1-22=-1299/197, 10-11=-1400/297 BOT CHORD 21-22=-499/417, 20-21=-523/887, 19-20=-417/733, 3-19=-149/258, 18-19=-1208/3133, 17-18=-711/2447, 6-17=-577/253, 13-14=-372/1098, 12-13=-164/329 WEBS 2-21=-963/158, 2-20=-900/545, 2-19=-1009/2666, 3-18=-818/502, 4-18=-0/388, 4-17=-734/242, 14-17=-355/1041, 7-17=-380/1451, 7-13=-684/164, 8-13=-618/207, 9-13=-273/1147, 9-12=-1144/402, 1-21=-141/1058, 10-12=-303/1269 NOTES- 1) Unbalancedroofliveloads have been considered for this design. 2)Wind:ASCE 7-10;Vult=115mph(3-second gust)Vasd=91mph;TCDL=6.0psf;BCDL=6.0psf; h=25ft; Cat. II;Exp C; enclosed; MWFRS(envelope) gable end zone and C-CExterior(2) 0-1-12 to 3-8-9,Interior(1) 3-8-9 to 20-10-0,Exterior(2) 20-10-0 to 35-6-4 zone;cantileverleft and right exposed ; end verticalleft and right exposed;C-C formembers and forces&MWFRS forreactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3)TCLL:ASCE 7-10;Pr=20.0 psf(roofliveload: Lumber DOL=1.15Plate DOL=1.15);Pg=20.0 psf(groundsnow);Pf=20.4 psf(flatroofsnow: Lumber DOL=1.15Plate DOL=1.15); CategoryII;Exp C; PartiallyExp.; Ct=1.1, Lu=50-0-0;Min. flatroofsnowload governs. Rainsurcharge applied to all exposedsurfaceswithslopesless than 0.500/12 in accordancewithIBC 1608.3.4. 4) Unbalancedsnowloads have been considered for this design.5)Provide adequate drainage to preventwater ponding. 6)This truss has been designed for a 10.0 psf bottomchordliveload nonconcurrentwith any otherliveloads. 7)Providemechanicalconnection(by others) of truss to bearing platecapable of withstanding 100 lb uplift at joint(s) except(jt=lb)22=208, 11=195. 8)This trussis designedin accordancewith the 2012 InternationalBuilding Code section 2306.1 and referencedstandardANSI/TPI 1. LOADCASE(S)Standard DE Job # 59223-W1 Dansco Engineering, LLC Date: 6/13/18 WARNING – VERIFY DESIGN PARAMETERS AND READ NOTES BEFORE FABRICATION AND INSTALLATION!!! This truss design is adequate for the design parameters shown. Review and approval of design parameters is the responsibility of the building designer, not the truss designer or truss engineer. Permanent bracing requirements against out-of-plane buckling are noted/shown for individual truss members (and for the truss as a whole) subjected to gravity and wind loads. Additional permanent bracing design shall be the responsibility of the design professional of record. Temporary and erection bracing shall be the responsibility of the contractor. Reference ANSI/TPI-1, “National Design Standard for Metal Plate Connected Wood Truss Construction” and TPI/WTCA BCSI-06, “Building Component Safety Information Guide to Good Practice for Handling, Installing, Restraining and Bracing of Metal Plate Connected Wood Trusses” for additional information. Job 1802242-12T Truss T26 TrussType PiggybackBase Qty 2 Ply 1 1802242-12TDWHWoodside-West Clay- 4 Job Reference (optional)Run:8.200 s Apr72018 Print:8.200 s Apr72018MiTekIndustries,Inc.Tue Jun1221:12:192018 Page1ID:bRTO9oDnRLEHvJjVgeMKW3yF_s1-cMgNkJYy4dMrlMLBwDCFzLlutj9J9m7OwM2HeJz6wGA Scale=1:94.5 T2 T3 T4 B1 B2 B3 B4 B5 W3 W5 W4 W6 W7 W8 W10 W9 W11 W12 W13 W12 W11 W14 W15 W1 W2 W17 W16 T1 B6 1 2 3 4 5 6 7 8 9 10 11 242322 21 20 19 18 17 16 15 14 13 12 25 26 27 28 29 30 31 3x6 5x10 5x6 3x4 4x6 6x12 2x4 3x4 4x8 6x8 4x6 5x6 6x10 4x4 3x4 5x6 1.5x4 4x8 4x4 3x4 4x6 4x6 4x4 5x6 1-0-01-0-0 2-6-0 1-6-0 8-8-06-2-0 14-10-06-2-0 20-10-06-0-0 26-11-06-1-0 33-0-06-1-0 38-0-45-0-4 43-4-05-3-12 1-0-0 1-0-0 2-6-0 1-6-0 8-8-0 6-2-0 14-10-0 6-2-0 20-10-0 6-0-0 26-11-0 6-1-0 33-0-0 6-1-0 38-0-4 5-0-4 43-4-0 5-3-12 1 -1 -0 11 -6 -0 6 -4 -0 1 -0 -0 11 -6 -0 6.0012 PlateOffsets(X,Y)-- [3:0-1-12,0-1-12], [7:0-7-8,0-2-8], [9:0-3-0,0-2-0], [12:Edge,0-3-8], [21:0-3-8,0-0-0] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 10.0 SPACING- PlateGrip DOL Lumber DOL RepStressIncr Code 2-0-0 1.15 1.15 YES IBC2012/TPI2007 CSI. TC BC WB Matrix-MSH 0.77 0.93 0.98 DEFL. Vert(LL) Vert(TL) Horz(TL) in -0.21 -0.50 0.28 (loc) 6 19-20 12 l/defl >999 >999 n/a L/d 240 180 n/a PLATES MT20 Weight: 284 lb FT= 20% GRIP 197/144 LUMBER- TOP CHORD2x4SPF No.2BOT CHORD2x4SPF No.2 *Except* B3,B5,B6: 2x6SPF No.2 WEBS 2x4SPF No.2 *Except*W3,W5,W6,W7,W10,W1,W2,W17: 2x4SPFStud BRACING- TOP CHORD Structuralwoodsheathing directly applied or 2-2-0 oc purlins,except end verticals. BOT CHORD Rigidceiling directly applied or 10-0-0 oc bracing,Except: 9-3-2 oc bracing: 22-232-2-0 oc bracing: 20-21 8-10-5 oc bracing: 19-20. WEBS 1 Row at midpt 7-17, 7-16, 8-16, 9-14, 10-13, 11-12 MiTekrecommends that Stabilizers and requiredcross bracingbeinstalled during truss erection,in accordancewithStabilizer Installation guide. REACTIONS.(lb/size)24=1570/0-6-0(min. 0-2-12), 12=1599/0-6-0(min. 0-2-14)Max Horz24=315(LC 13) Max Uplift24=-233(LC 16), 12=-139(LC 17) MaxGrav24=1752(LC 38), 12=1838(LC 38) FORCES.(lb)-Max. Comp./Max.Ten.-All forces 250 (lb) orless exceptwhenshown. TOP CHORD 1-2=-1221/194, 2-3=-4385/920, 3-25=-3573/556, 4-25=-3531/579, 4-26=-2881/489, 5-26=-2872/493, 5-27=-2759/507, 6-27=-2668/523, 6-7=-2890/661, 7-8=-1590/460, 8-28=-1590/460, 28-29=-1590/460, 9-29=-1590/460, 9-10=-1445/414, 10-30=-986/301, 30-31=-1084/286, 11-31=-1168/276, 1-24=-1576/258, 11-12=-1786/347 BOT CHORD 23-24=-309/289, 22-23=-404/1070, 21-22=-296/784, 3-21=-132/376, 20-21=-1168/4214, 19-20=-702/3159, 6-19=-576/253, 16-17=-366/1682, 15-16=-257/1215, 14-15=-257/1215, 13-14=-224/970 WEBS 2-23=-1197/196, 2-22=-905/375, 2-21=-959/3512, 3-20=-1170/471, 4-20=0/433, 4-19=-808/253, 17-19=-321/1494, 7-19=-387/1567, 7-16=-356/132, 8-16=-617/204, 9-16=-169/841, 9-14=-434/157, 10-14=-111/636, 10-13=-1018/272, 1-23=-193/1300, 11-13=-254/1469 NOTES- 1) Unbalancedroofliveloads have been considered for this design.2)Wind:ASCE 7-10;Vult=115mph(3-second gust)Vasd=91mph;TCDL=6.0psf;BCDL=6.0psf; h=25ft; Cat. II;Exp C; enclosed; MWFRS(envelope) gable end zone and C-CExterior(2) 0-1-12 to 4-5-12,Interior(1) 4-5-12 to 20-10-0,Exterior(2) 20-10-0 to 39-1-9, Interior(1) 39-1-9 to 43-2-4zone;cantileverleft and right exposed ; end verticalleft and right exposed;C-C formembers and forces &MWFRS forreactionsshown; Lumber DOL=1.60 plate grip DOL=1.60 3)TCLL:ASCE 7-10;Pr=20.0 psf(roofliveload: Lumber DOL=1.15Plate DOL=1.15);Pg=20.0 psf(groundsnow);Pf=20.4 psf(flat roofsnow: Lumber DOL=1.15Plate DOL=1.15); CategoryII;Exp C; PartiallyExp.; Ct=1.1, Lu=50-0-0;Min. flatroofsnowloadgoverns. Rainsurcharge applied to all exposedsurfaceswithslopesless than 0.500/12 in accordancewithIBC 1608.3.4. 4) Unbalancedsnowloads have been considered for this design. 5)Provide adequate drainage to preventwater ponding.6)This truss has been designed for a 10.0 psf bottomchordliveload nonconcurrentwith any otherliveloads. Continued on page 2 DE Job # 59223-W1 Dansco Engineering, LLC Date: 6/13/18 WARNING – VERIFY DESIGN PARAMETERS AND READ NOTES BEFORE FABRICATION AND INSTALLATION!!! This truss design is adequate for the design parameters shown. Review and approval of design parameters is the responsibility of the building designer, not the truss designer or truss engineer. Permanent bracing requirements against out-of-plane buckling are noted/shown for individual truss members (and for the truss as a whole) subjected to gravity and wind loads. Additional permanent bracing design shall be the responsibility of the design professional of record. Temporary and erection bracing shall be the responsibility of the contractor. Reference ANSI/TPI-1, “National Design Standard for Metal Plate Connected Wood Truss Construction” and TPI/WTCA BCSI-06, “Building Component Safety Information Guide to Good Practice for Handling, Installing, Restraining and Bracing of Metal Plate Connected Wood Trusses” for additional information. Job 1802242-12T Truss T26 TrussType PiggybackBase Qty 2 Ply 1 1802242-12TDWHWoodside-West Clay- 4 Job Reference (optional)Run:8.200 s Apr72018 Print:8.200 s Apr72018MiTekIndustries,Inc.Tue Jun1221:12:192018 Page2ID:bRTO9oDnRLEHvJjVgeMKW3yF_s1-cMgNkJYy4dMrlMLBwDCFzLlutj9J9m7OwM2HeJz6wGA NOTES- 7)Providemechanicalconnection(by others) of truss to bearing platecapable of withstanding 100 lb uplift at joint(s) except(jt=lb) 24=233, 12=139. 8)This trussis designedin accordancewith the 2012 InternationalBuilding Code section 2306.1 and referencedstandardANSI/TPI 1. LOADCASE(S)Standard DE Job # 59223-W1 Dansco Engineering, LLC Date: 6/13/18 WARNING – VERIFY DESIGN PARAMETERS AND READ NOTES BEFORE FABRICATION AND INSTALLATION!!! This truss design is adequate for the design parameters shown. Review and approval of design parameters is the responsibility of the building designer, not the truss designer or truss engineer. Permanent bracing requirements against out-of-plane buckling are noted/shown for individual truss members (and for the truss as a whole) subjected to gravity and wind loads. Additional permanent bracing design shall be the responsibility of the design professional of record. Temporary and erection bracing shall be the responsibility of the contractor. Reference ANSI/TPI-1, “National Design Standard for Metal Plate Connected Wood Truss Construction” and TPI/WTCA BCSI-06, “Building Component Safety Information Guide to Good Practice for Handling, Installing, Restraining and Bracing of Metal Plate Connected Wood Trusses” for additional information. Job 1802242-12T Truss T27 TrussType PiggybackBase Qty 1 Ply 1 1802242-12TDWHWoodside-West Clay- 4 Job Reference (optional)Run:8.200 s Apr72018 Print:8.200 s Apr72018MiTekIndustries,Inc.Tue Jun1221:12:202018 Page1ID:bRTO9oDnRLEHvJjVgeMKW3yF_s1-5YElxfZarwUiNWwNUwjUWZH2F7c5uEbX80nrAlz6wG9 Scale=1:80.7 T2 T3 T4 B1 W3 W4 W5 W6 W7 W8 W9 W8 W7 W10 W11 W1 W2 W13 W12 T1 B3B2 1 2 3 4 5 6 7 8 9 19 18 17 16 15 14 13 12 11 10 20 21 22 23 24 25 26 3x6 5x6 4x6 4x8 3x4 6x6 4x4 3x4 4x4 5x6 1.5x4 4x8 4x4 3x4 4x6 4x8 4x4 5x6 4x8 7-1-11 7-1-11 13-11-13 6-10-3 20-10-0 6-10-3 26-11-0 6-1-0 33-0-0 6-1-0 38-0-4 5-0-4 43-4-0 5-3-12 7-1-11 7-1-11 13-11-13 6-10-3 20-10-0 6-10-3 26-11-0 6-1-0 33-0-0 6-1-0 38-0-4 5-0-4 43-4-0 5-3-12 1 -1 -0 11 -6 -0 6 -4 -0 11 -6 -0 6.0012 PlateOffsets(X,Y)-- [5:0-3-0,0-2-0], [7:0-3-0,0-2-0], [10:Edge,0-3-8], [18:0-3-0,0-2-12] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 10.0 SPACING- PlateGrip DOL Lumber DOL RepStressIncr Code 2-0-0 1.15 1.15 YES IBC2012/TPI2007 CSI. TC BC WB Matrix-MSH 0.86 0.51 0.91 DEFL. Vert(LL) Vert(TL) Horz(TL) in -0.13 -0.32 0.07 (loc) 17 15-17 10 l/defl >999 >999 n/a L/d 240 180 n/a PLATES MT20 Weight: 273 lb FT= 20% GRIP 197/144 LUMBER- TOP CHORD2x4SPF No.2BOT CHORD2x6SPF No.2 WEBS 2x4SPF No.2 *Except* W3,W2,W13: 2x4SPFStud,W1: 2x6SPF No.2 BRACING- TOP CHORD Structuralwoodsheathing directly applied, except end verticals.BOT CHORD Rigidceiling directly applied or 9-9-7 oc bracing. WEBS 1 Row at midpt 4-15, 5-14, 6-14, 7-12, 8-11, 9-10 MiTekrecommends that Stabilizers and requiredcross bracing beinstalled during truss erection,in accordancewithStabilizerInstallation guide. REACTIONS.(lb/size)19=1567/Mechanical, 10=1596/0-6-0(min. 0-2-14) Max Horz19=313(LC 13)Max Uplift19=-232(LC 16), 10=-138(LC 17) MaxGrav19=1749(LC 38), 10=1835(LC 38) FORCES.(lb)-Max. Comp./Max.Ten.-All forces 250 (lb) orless exceptwhenshown. TOP CHORD 1-20=-2855/416, 2-20=-2714/436, 2-21=-2626/433, 3-21=-2530/448, 3-4=-2417/466, 4-22=-2039/437, 5-22=-1887/470, 5-6=-1586/460, 6-23=-1586/460, 23-24=-1586/460,7-24=-1586/460, 7-8=-1441/414, 8-25=-984/301, 25-26=-1082/286, 9-26=-1166/276, 1-19=-1649/312, 9-10=-1783/347 BOT CHORD 18-19=-354/500, 17-18=-567/2489, 16-17=-502/2263, 15-16=-502/2263, 14-15=-367/1676, 13-14=-257/1211, 12-13=-257/1211, 11-12=-224/968 WEBS 2-17=-311/175, 4-17=-13/402, 4-15=-878/277, 5-15=-131/787, 5-14=-353/132, 6-14=-617/204, 7-14=-170/840, 7-12=-435/157, 8-12=-110/634, 8-11=-1015/272, 1-18=-215/2104, 9-11=-254/1466 NOTES- 1) Unbalancedroofliveloads have been considered for this design. 2)Wind:ASCE 7-10;Vult=115mph(3-second gust)Vasd=91mph;TCDL=6.0psf;BCDL=6.0psf; h=25ft; Cat. II;Exp C; enclosed; MWFRS(envelope) gable end zone and C-CExterior(2) 0-2-12 to 4-6-12,Interior(1) 4-6-12 to 20-10-0,Exterior(2) 20-10-0 to 39-1-9, Interior(1) 39-1-9 to 43-2-4zone;cantileverleft and right exposed ; end verticalleft and right exposed;C-C formembers and forces & MWFRS forreactionsshown; Lumber DOL=1.60 plate grip DOL=1.60 3)TCLL:ASCE 7-10;Pr=20.0 psf(roofliveload: Lumber DOL=1.15Plate DOL=1.15);Pg=20.0 psf(groundsnow);Pf=20.4 psf(flat roofsnow: Lumber DOL=1.15Plate DOL=1.15); CategoryII;Exp C; PartiallyExp.; Ct=1.1, Lu=50-0-0;Min. flatroofsnowloadgoverns. Rainsurcharge applied to all exposedsurfaceswithslopesless than 0.500/12 in accordancewithIBC 1608.3.4. 4) Unbalancedsnowloads have been considered for this design. 5)Provide adequate drainage to preventwater ponding.6)This truss has been designed for a 10.0 psf bottomchordliveload nonconcurrentwith any otherliveloads. 7) Refer to girder(s) for truss to trussconnections. 8)Providemechanicalconnection(by others) of truss to bearing platecapable of withstanding 100 lb uplift at joint(s) except(jt=lb)19=232, 10=138. 9)This trussis designedin accordancewith the 2012 InternationalBuilding Code section 2306.1 and referencedstandardANSI/TPI 1. LOADCASE(S)Standard DE Job # 59223-W1 Dansco Engineering, LLC Date: 6/13/18 WARNING – VERIFY DESIGN PARAMETERS AND READ NOTES BEFORE FABRICATION AND INSTALLATION!!! This truss design is adequate for the design parameters shown. Review and approval of design parameters is the responsibility of the building designer, not the truss designer or truss engineer. Permanent bracing requirements against out-of-plane buckling are noted/shown for individual truss members (and for the truss as a whole) subjected to gravity and wind loads. Additional permanent bracing design shall be the responsibility of the design professional of record. Temporary and erection bracing shall be the responsibility of the contractor. Reference ANSI/TPI-1, “National Design Standard for Metal Plate Connected Wood Truss Construction” and TPI/WTCA BCSI-06, “Building Component Safety Information Guide to Good Practice for Handling, Installing, Restraining and Bracing of Metal Plate Connected Wood Trusses” for additional information. Job 1802242-12T Truss T28 TrussType PiggybackBase Qty 1 Ply 1 1802242-12TDWHWoodside-West Clay- 4 Job Reference (optional)Run:8.200 s Apr72018 Print:8.200 s Apr72018MiTekIndustries,Inc.Tue Jun1221:12:222018 Page1ID:bRTO9oDnRLEHvJjVgeMKW3yF_s1-1xLVMLbqMYkQcq4mbLlyb_NPCwG1MF7qcJGxFez6wG7 Scale=1:97.5 T2 T3 T2 B1 W1 W2 W3 W4 W5 W6 W7 W6 W5 W8 W9 W10 W11 HW2 T1 T4 B3B1B2 HW11 2 3 4 5 6 7 8 9 10 11 12 22 21 20 19 18 17 16 15 14 13 30 31 32 33 34 35 3637 38 39 40 41 4x6 6x6 4x6 5x12MT18H 4x6 4x62x4 4x8 6x6 2x4 2x4 6x84x64x6 7-1-11 7-1-11 13-11-13 6-10-3 20-10-0 6-10-3 26-11-0 6-1-0 33-0-0 6-1-0 40-0-3 7-0-3 47-0-5 7-0-3 54-4-0 7-3-11 7-1-11 7-1-11 13-11-13 6-10-3 20-10-0 6-10-3 26-11-0 6-1-0 33-0-0 6-1-0 40-0-3 7-0-3 47-0-5 7-0-3 54-4-0 7-3-11 1 -1 -0 11 -6 -0 0 -10 -0 11 -6 -0 6.0012 PlateOffsets(X,Y)-- [1:0-6-14,Edge], [12:0-0-0,0-1-11] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 10.0 SPACING- PlateGrip DOL Lumber DOL RepStressIncr Code 2-0-0 1.15 1.15 YES IBC2012/TPI2007 CSI. TC BC WB Matrix-MSH 0.83 0.61 0.45 DEFL. Vert(LL) Vert(TL) Horz(TL) in -0.20 -0.48 0.16 (loc) 19 17-19 12 l/defl >999 >999 n/a L/d 240 180 n/a PLATES MT20 MT18H Weight: 364 lb FT= 20% GRIP 197/144 197/144 LUMBER- TOP CHORD2x6SPF No.2BOT CHORD2x6SP 2400F 2.0E WEBS 2x4SPF No.2 *Except* W1,W11: 2x4SPFStudWEDGE Right: 2x4SPFStud SLIDER Left 2x4SPFStud 1-6-0 BRACING- TOP CHORD Structuralwoodsheathing directly applied or 2-2-0 oc purlins.BOT CHORD Rigidceiling directly applied or 10-0-0 oc bracing. WEBS 1 Row at midpt 5-19, 6-17, 7-17, 8-17, 9-16 MiTekrecommends that Stabilizers and requiredcross bracing beinstalled during truss erection,in accordancewithStabilizerInstallation guide. REACTIONS.(lb/size)1=1985/Mechanical, 12=1984/0-6-0(min. 0-1-13) Max Horz1=-194(LC 17)Max Uplift1=-255(LC 16), 12=-260(LC 17) MaxGrav1=2226(LC 38), 12=2221(LC 38) FORCES.(lb)-Max. Comp./Max.Ten.-All forces 250 (lb) orless exceptwhenshown. TOP CHORD 1-2=-1594/149, 2-30=-3810/592, 3-30=-3689/624, 3-4=-3645/629, 4-31=-3617/632, 31-32=-3585/637, 32-33=-3520/654, 5-33=-3451/659, 5-6=-3071/660, 6-34=-2696/657, 34-35=-2696/657, 7-35=-2696/657, 7-36=-2696/657, 36-37=-2696/657, 8-37=-2696/657, 8-9=-3100/663, 9-38=-3519/671, 38-39=-3546/668, 39-40=-3672/650, 10-40=-3705/646, 10-11=-3756/637, 11-41=-3967/655, 12-41=-4084/637 BOT CHORD 1-22=-466/3300, 21-22=-466/3300, 20-21=-417/3206, 19-20=-417/3206, 18-19=-266/2593, 17-18=-266/2593, 16-17=-255/2618, 15-16=-416/3285, 14-15=-416/3285, 13-14=-486/3557, 12-13=-486/3557 WEBS 5-21=-11/387, 5-19=-910/281, 6-19=-133/791, 6-17=-147/509, 7-17=-601/199, 8-17=-148/471, 8-16=-136/834, 9-16=-972/291, 9-14=-15/448, 11-14=-388/200 NOTES- 1) Unbalancedroofliveloads have been considered for this design. 2)Wind:ASCE 7-10;Vult=115mph(3-second gust)Vasd=91mph;TCDL=6.0psf;BCDL=6.0psf; h=25ft; Cat. II;Exp C; enclosed; MWFRS(envelope) gable end zone and C-CExterior(2) 0-0-0 to 5-5-3,Interior(1) 5-5-3 to 20-10-0,Exterior(2) 20-10-0 to 40-8-3,Interior(1) 40-8-3 to 54-4-0zone;cantileverleft and right exposed ; end verticalleft and right exposed;C-C formembers and forces & MWFRS forreactionsshown; Lumber DOL=1.60 plate grip DOL=1.60 3)TCLL:ASCE 7-10;Pr=20.0 psf(roofliveload: Lumber DOL=1.15Plate DOL=1.15);Pg=20.0 psf(groundsnow);Pf=20.4 psf(flatroofsnow: Lumber DOL=1.15Plate DOL=1.15); CategoryII;Exp C; PartiallyExp.; Ct=1.1, Lu=50-0-0;Min. flatroofsnowload governs. Rainsurcharge applied to all exposedsurfaceswithslopesless than 0.500/12 in accordancewithIBC 1608.3.4. 4) Unbalancedsnowloads have been considered for this design.5)Provide adequate drainage to preventwater ponding. 6)All plates areMT20 plates unless otherwiseindicated. 7)All plates are 4x4MT20 unless otherwiseindicated. 8)This truss has been designed for a 10.0 psf bottomchordliveload nonconcurrentwith any otherliveloads. 9) Refer to girder(s) for truss to trussconnections. Continued on page 2 DE Job # 59223-W1 Dansco Engineering, LLC Date: 6/13/18 WARNING – VERIFY DESIGN PARAMETERS AND READ NOTES BEFORE FABRICATION AND INSTALLATION!!! This truss design is adequate for the design parameters shown. Review and approval of design parameters is the responsibility of the building designer, not the truss designer or truss engineer. Permanent bracing requirements against out-of-plane buckling are noted/shown for individual truss members (and for the truss as a whole) subjected to gravity and wind loads. Additional permanent bracing design shall be the responsibility of the design professional of record. Temporary and erection bracing shall be the responsibility of the contractor. Reference ANSI/TPI-1, “National Design Standard for Metal Plate Connected Wood Truss Construction” and TPI/WTCA BCSI-06, “Building Component Safety Information Guide to Good Practice for Handling, Installing, Restraining and Bracing of Metal Plate Connected Wood Trusses” for additional information. Job 1802242-12T Truss T28 TrussType PiggybackBase Qty 1 Ply 1 1802242-12TDWHWoodside-West Clay- 4 Job Reference (optional)Run:8.200 s Apr72018 Print:8.200 s Apr72018MiTekIndustries,Inc.Tue Jun1221:12:222018 Page2ID:bRTO9oDnRLEHvJjVgeMKW3yF_s1-1xLVMLbqMYkQcq4mbLlyb_NPCwG1MF7qcJGxFez6wG7 NOTES- 10)Providemechanicalconnection(by others) of truss to bearing platecapable of withstanding 100 lb uplift at joint(s) except(jt=lb) 1=255, 12=260. 11)This trussis designedin accordancewith the 2012 InternationalBuilding Code section 2306.1 and referencedstandardANSI/TPI 1. LOADCASE(S)Standard DE Job # 59223-W1 Dansco Engineering, LLC Date: 6/13/18 WARNING – VERIFY DESIGN PARAMETERS AND READ NOTES BEFORE FABRICATION AND INSTALLATION!!! This truss design is adequate for the design parameters shown. Review and approval of design parameters is the responsibility of the building designer, not the truss designer or truss engineer. Permanent bracing requirements against out-of-plane buckling are noted/shown for individual truss members (and for the truss as a whole) subjected to gravity and wind loads. Additional permanent bracing design shall be the responsibility of the design professional of record. Temporary and erection bracing shall be the responsibility of the contractor. Reference ANSI/TPI-1, “National Design Standard for Metal Plate Connected Wood Truss Construction” and TPI/WTCA BCSI-06, “Building Component Safety Information Guide to Good Practice for Handling, Installing, Restraining and Bracing of Metal Plate Connected Wood Trusses” for additional information. Job 1802242-12T Truss T29 TrussType Hip Qty 1 Ply 1 1802242-12TDWHWoodside-West Clay- 4 Job Reference (optional)Run:8.200 s Apr72018 Print:8.200 s Apr72018MiTekIndustries,Inc.Tue Jun1221:12:242018 Page1ID:bRTO9oDnRLEHvJjVgeMKW3yF_s1-zKTFn1c4u9_8s8E8jmnQgPSkMkxLq9l73dl2JWz6wG5 Scale=1:99.4 0 -1 -14 0 -1 -14 T2 T3 T2 B1 W1 W2 W3 W4 W5 W6 W7 W6 W5 W4 W3 W2 W1HW1 T1 T4 B4B3B2 HW2 1 2 3 4 5 6 7 8 9 10 11 12 22 21 20 19 18 17 16 15 14 13 30 31 32 33 34 35 36 37 38 39 5x6 6x6 6x6 4x6 5x12MT18H 4x6 4x62x4 4x8 2x4 2x4 6x85x6 4x6 7-2-5 7-2-5 14-7-6 7-5-0 22-0-6 7-5-0 26-11-0 4-10-10 31-9-10 4-10-10 39-2-10 7-5-0 46-7-11 7-5-0 54-4-0 7-8-5 7-2-5 7-2-5 14-7-6 7-5-0 22-0-6 7-5-0 26-11-0 4-10-10 31-9-10 4-10-10 39-2-10 7-5-0 46-7-11 7-5-0 54-4-0 7-8-5 1 -1 -0 11 -11 -5 12 -1 -3 0 -10 -0 11 -11 -5 6.0012 PlateOffsets(X,Y)-- [1:0-6-14,Edge], [12:0-0-0,0-1-7] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 10.0 SPACING- PlateGrip DOL Lumber DOL RepStressIncr Code 2-0-0 1.15 1.15 YES IBC2012/TPI2007 CSI. TC BC WB Matrix-MSH 0.85 0.62 0.51 DEFL. Vert(LL) Vert(TL) Horz(TL) in -0.21 -0.49 0.16 (loc) 16 15-16 12 l/defl >999 >999 n/a L/d 240 180 n/a PLATES MT20 MT18H Weight: 370 lb FT= 20% GRIP 197/144 197/144 LUMBER- TOP CHORD2x6SPF No.2BOT CHORD2x6SP 2400F 2.0E WEBS 2x4SPF No.2 *Except* W1: 2x4SPFStudWEDGE Right: 2x4SPFStud SLIDER Left 2x4SPFStud 1-6-0 BRACING- TOP CHORD Structuralwoodsheathing directly applied or 2-2-0 oc purlins.BOT CHORD Rigidceiling directly applied or 10-0-0 oc bracing. WEBS 1 Row at midpt 3-21, 5-19, 6-18, 7-18, 8-18, 9-16, 11-15 MiTekrecommends that Stabilizers and requiredcross bracing beinstalled during truss erection,in accordancewithStabilizerInstallation guide. REACTIONS.(lb/size)1=1973/Mechanical, 12=1972/0-6-0(min. 0-1-14) Max Horz1=-203(LC 17)Max Uplift1=-266(LC 16), 12=-271(LC 17) MaxGrav1=2252(LC 38), 12=2246(LC 38) FORCES.(lb)-Max. Comp./Max.Ten.-All forces 250 (lb) orless exceptwhenshown. TOP CHORD 1-2=-1616/144, 2-30=-3867/585, 3-30=-3745/618, 3-4=-3686/617, 4-31=-3633/620, 31-32=-3629/620, 5-32=-3492/643, 5-6=-3077/645, 6-33=-2667/642, 33-34=-2668/641, 7-34=-2669/641, 7-35=-2669/641, 35-36=-2668/641, 8-36=-2667/642, 8-9=-3096/648, 9-37=-3564/655, 37-38=-3692/633, 10-38=-3705/632, 10-11=-3775/628, 11-39=-4023/648, 12-39=-4140/628 BOT CHORD 1-22=-494/3349, 21-22=-494/3349, 20-21=-395/3246, 19-20=-395/3246, 18-19=-243/2607, 17-18=-234/2626, 16-17=-234/2626, 15-16=-391/3302, 14-15=-472/3604, 13-14=-472/3604, 12-13=-472/3604 WEBS 5-21=-3/427, 5-19=-929/294, 6-19=-138/781, 6-18=-137/460, 7-18=-507/157, 8-18=-138/423, 8-16=-144/829, 9-16=-984/301, 9-15=-15/487, 11-15=-446/214 NOTES- 1) Unbalancedroofliveloads have been considered for this design. 2)Wind:ASCE 7-10;Vult=115mph(3-second gust)Vasd=91mph;TCDL=6.0psf;BCDL=6.0psf; h=25ft; Cat. II;Exp C; enclosed; MWFRS(envelope) gable end zone and C-CExterior(2) 0-0-0 to 5-5-3,Interior(1) 5-5-3 to 22-0-6,Exterior(2) 22-0-6 to 39-2-10,Interior(1) 39-2-10 to 54-4-0zone;cantileverleft and right exposed ; end verticalleft and right exposed;C-C formembers and forces &MWFRS forreactionsshown; Lumber DOL=1.60 plate grip DOL=1.60 3)TCLL:ASCE 7-10;Pr=20.0 psf(roofliveload: Lumber DOL=1.15Plate DOL=1.15);Pg=20.0 psf(groundsnow);Pf=20.4 psf(flatroofsnow: Lumber DOL=1.15Plate DOL=1.15); CategoryII;Exp C; PartiallyExp.; Ct=1.1, Lu=50-0-0;Min. flatroofsnowload governs. Rainsurcharge applied to all exposedsurfaceswithslopesless than 0.500/12 in accordancewithIBC 1608.3.4. 4) Unbalancedsnowloads have been considered for this design.5)Provide adequate drainage to preventwater ponding. 6)All plates areMT20 plates unless otherwiseindicated. 7)All plates are 4x4MT20 unless otherwiseindicated. 8)This truss has been designed for a 10.0 psf bottomchordliveload nonconcurrentwith any otherliveloads. 9) Refer to girder(s) for truss to trussconnections. Continued on page 2 DE Job # 59223-W1 Dansco Engineering, LLC Date: 6/13/18 WARNING – VERIFY DESIGN PARAMETERS AND READ NOTES BEFORE FABRICATION AND INSTALLATION!!! This truss design is adequate for the design parameters shown. Review and approval of design parameters is the responsibility of the building designer, not the truss designer or truss engineer. Permanent bracing requirements against out-of-plane buckling are noted/shown for individual truss members (and for the truss as a whole) subjected to gravity and wind loads. Additional permanent bracing design shall be the responsibility of the design professional of record. Temporary and erection bracing shall be the responsibility of the contractor. Reference ANSI/TPI-1, “National Design Standard for Metal Plate Connected Wood Truss Construction” and TPI/WTCA BCSI-06, “Building Component Safety Information Guide to Good Practice for Handling, Installing, Restraining and Bracing of Metal Plate Connected Wood Trusses” for additional information. Job 1802242-12T Truss T29 TrussType Hip Qty 1 Ply 1 1802242-12TDWHWoodside-West Clay- 4 Job Reference (optional)Run:8.200 s Apr72018 Print:8.200 s Apr72018MiTekIndustries,Inc.Tue Jun1221:12:242018 Page2ID:bRTO9oDnRLEHvJjVgeMKW3yF_s1-zKTFn1c4u9_8s8E8jmnQgPSkMkxLq9l73dl2JWz6wG5 NOTES- 10)Providemechanicalconnection(by others) of truss to bearing platecapable of withstanding 100 lb uplift at joint(s) except(jt=lb) 1=266, 12=271. 11)This trussis designedin accordancewith the 2012 InternationalBuilding Code section 2306.1 and referencedstandardANSI/TPI 1. LOADCASE(S)Standard DE Job # 59223-W1 Dansco Engineering, LLC Date: 6/13/18 WARNING – VERIFY DESIGN PARAMETERS AND READ NOTES BEFORE FABRICATION AND INSTALLATION!!! This truss design is adequate for the design parameters shown. Review and approval of design parameters is the responsibility of the building designer, not the truss designer or truss engineer. Permanent bracing requirements against out-of-plane buckling are noted/shown for individual truss members (and for the truss as a whole) subjected to gravity and wind loads. Additional permanent bracing design shall be the responsibility of the design professional of record. Temporary and erection bracing shall be the responsibility of the contractor. Reference ANSI/TPI-1, “National Design Standard for Metal Plate Connected Wood Truss Construction” and TPI/WTCA BCSI-06, “Building Component Safety Information Guide to Good Practice for Handling, Installing, Restraining and Bracing of Metal Plate Connected Wood Trusses” for additional information. Job 1802242-12T Truss T30 TrussType Hip Qty 1 Ply 1 1802242-12TDWHWoodside-West Clay- 4 Job Reference (optional)Run:8.200 s Apr72018 Print:8.200 s Apr72018MiTekIndustries,Inc.Tue Jun1221:12:252018 Page1ID:bRTO9oDnRLEHvJjVgeMKW3yF_s1-RW1e_MdifT6?THpLGTIfDc?xY8H9ZcDGIHVcsyz6wG4 Scale=1:97.9 0 -1 -14 0 -1 -14 T2 T3 T2 B1 W1 W2 W3 W4 W5 W6 W7 W6 W5 W4 W3 W2 W1 HW1 T1 T4 B3B1B2 HW2 1 2 3 4 5 6 7 8 9 10 11 12 22 21 20 19 18 17 16 15 14 13 30 31 32 33 34 35 36 37 38 39 5x6 6x6 6x6 4x6 5x12 4x6 4x62x4 4x8 2x4 2x4 6x84x64x6 6-2-7 6-2-7 12-7-7 6-4-15 19-0-6 6-4-15 26-11-0 7-10-10 34-9-10 7-10-10 41-2-9 6-4-15 47-7-9 6-4-15 54-4-0 6-8-7 6-2-7 6-2-7 12-7-7 6-4-15 19-0-6 6-4-15 26-11-0 7-10-10 34-9-10 7-10-10 41-2-9 6-4-15 47-7-9 6-4-15 54-4-0 6-8-7 1 -1 -0 10 -5 -5 10 -7 -3 0 -10 -0 10 -5 -5 6.0012 PlateOffsets(X,Y)-- [1:0-6-14,Edge], [12:0-0-0,0-1-11] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 10.0 SPACING- PlateGrip DOL Lumber DOL RepStressIncr Code 2-0-0 1.15 1.15 YES IBC2012/TPI2007 CSI. TC BC WB Matrix-MSH 0.76 0.58 0.50 DEFL. Vert(LL) Vert(TL) Horz(TL) in -0.19 -0.49 0.15 (loc) 17 16-17 12 l/defl >999 >999 n/a L/d 240 180 n/a PLATES MT20 Weight: 355 lb FT= 20% GRIP 197/144 LUMBER- TOP CHORD2x6SPF No.2BOT CHORD2x6SP 2400F 2.0E WEBS 2x4SPF No.2 *Except* W1,W2,W3: 2x4SPFStudWEDGE Right: 2x4SPFStud SLIDER Left 2x4SPFStud 1-6-0 BRACING- TOP CHORD Structuralwoodsheathing directly applied or 2-4-8 oc purlins.BOT CHORD Rigidceiling directly applied or 10-0-0 oc bracing. WEBS 1 Row at midpt 5-19, 7-17, 9-16 MiTekrecommends that Stabilizers and requiredcross bracing beinstalled during truss erection,in accordancewithStabilizerInstallation guide. REACTIONS.(lb/size)1=2003/Mechanical, 12=2002/0-6-0(min. 0-1-13) Max Horz1=-177(LC 17)Max Uplift1=-238(LC 16), 12=-244(LC 17) MaxGrav1=2187(LC 38), 12=2182(LC 38) FORCES.(lb)-Max. Comp./Max.Ten.-All forces 250 (lb) orless exceptwhenshown. TOP CHORD 1-2=-1576/188, 2-30=-3692/597, 3-30=-3587/625, 3-31=-3614/645, 4-31=-3560/651, 4-32=-3551/653, 32-33=-3520/657, 5-33=-3420/674, 5-6=-3104/674, 6-34=-3003/695, 7-34=-3004/694, 7-35=-3004/694, 8-35=-3003/695, 8-9=-3138/680, 9-36=-3514/690, 36-37=-3610/673, 10-37=-3635/671, 10-38=-3654/667, 11-38=-3708/659, 11-39=-3879/662, 12-39=-3996/645 BOT CHORD 1-22=-472/3196, 21-22=-472/3196, 20-21=-449/3176, 19-20=-449/3176, 18-19=-310/2698, 17-18=-310/2698, 16-17=-302/2730, 15-16=-447/3251, 14-15=-447/3251, 13-14=-503/3481, 12-13=-503/3481 WEBS 5-21=-4/313, 5-19=-791/255, 6-19=-104/716, 6-17=-176/666, 7-17=-832/267, 8-17=-175/623, 8-16=-109/768, 9-16=-853/262, 9-14=-17/382, 11-14=-297/178 NOTES- 1) Unbalancedroofliveloads have been considered for this design. 2)Wind:ASCE 7-10;Vult=115mph(3-second gust)Vasd=91mph;TCDL=6.0psf;BCDL=6.0psf; h=25ft; Cat. II;Exp C; enclosed; MWFRS(envelope) gable end zone and C-CExterior(2) 0-0-0 to 5-5-3,Interior(1) 5-5-3 to 19-0-6,Exterior(2) 19-0-6 to 42-5-13,Interior(1) 42-5-13 to 54-4-0zone;cantileverleft and right exposed ; end verticalleft and right exposed;C-C formembers and forces &MWFRS forreactionsshown; Lumber DOL=1.60 plate grip DOL=1.60 3)TCLL:ASCE 7-10;Pr=20.0 psf(roofliveload: Lumber DOL=1.15Plate DOL=1.15);Pg=20.0 psf(groundsnow);Pf=20.4 psf(flatroofsnow: Lumber DOL=1.15Plate DOL=1.15); CategoryII;Exp C; PartiallyExp.; Ct=1.1, Lu=50-0-0;Min. flatroofsnowload governs. Rainsurcharge applied to all exposedsurfaceswithslopesless than 0.500/12 in accordancewithIBC 1608.3.4. 4) Unbalancedsnowloads have been considered for this design.5)Provide adequate drainage to preventwater ponding. 6)All plates are 4x4MT20 unless otherwiseindicated. 7)This truss has been designed for a 10.0 psf bottomchordliveload nonconcurrentwith any otherliveloads. 8) Refer to girder(s) for truss to trussconnections. 9)Providemechanicalconnection(by others) of truss to bearing platecapable of withstanding 100 lb uplift at joint(s) except(jt=lb) 1=238, 12=244.Continued on page 2 DE Job # 59223-W1 Dansco Engineering, LLC Date: 6/13/18 WARNING – VERIFY DESIGN PARAMETERS AND READ NOTES BEFORE FABRICATION AND INSTALLATION!!! This truss design is adequate for the design parameters shown. Review and approval of design parameters is the responsibility of the building designer, not the truss designer or truss engineer. Permanent bracing requirements against out-of-plane buckling are noted/shown for individual truss members (and for the truss as a whole) subjected to gravity and wind loads. Additional permanent bracing design shall be the responsibility of the design professional of record. Temporary and erection bracing shall be the responsibility of the contractor. Reference ANSI/TPI-1, “National Design Standard for Metal Plate Connected Wood Truss Construction” and TPI/WTCA BCSI-06, “Building Component Safety Information Guide to Good Practice for Handling, Installing, Restraining and Bracing of Metal Plate Connected Wood Trusses” for additional information. Job 1802242-12T Truss T30 TrussType Hip Qty 1 Ply 1 1802242-12TDWHWoodside-West Clay- 4 Job Reference (optional)Run:8.200 s Apr72018 Print:8.200 s Apr72018MiTekIndustries,Inc.Tue Jun1221:12:252018 Page2ID:bRTO9oDnRLEHvJjVgeMKW3yF_s1-RW1e_MdifT6?THpLGTIfDc?xY8H9ZcDGIHVcsyz6wG4 NOTES- 10)This trussis designedin accordancewith the 2012 InternationalBuilding Code section 2306.1 and referencedstandardANSI/TPI 1. LOADCASE(S)Standard DE Job # 59223-W1 Dansco Engineering, LLC Date: 6/13/18 WARNING – VERIFY DESIGN PARAMETERS AND READ NOTES BEFORE FABRICATION AND INSTALLATION!!! This truss design is adequate for the design parameters shown. Review and approval of design parameters is the responsibility of the building designer, not the truss designer or truss engineer. Permanent bracing requirements against out-of-plane buckling are noted/shown for individual truss members (and for the truss as a whole) subjected to gravity and wind loads. Additional permanent bracing design shall be the responsibility of the design professional of record. Temporary and erection bracing shall be the responsibility of the contractor. Reference ANSI/TPI-1, “National Design Standard for Metal Plate Connected Wood Truss Construction” and TPI/WTCA BCSI-06, “Building Component Safety Information Guide to Good Practice for Handling, Installing, Restraining and Bracing of Metal Plate Connected Wood Trusses” for additional information. Job 1802242-12T Truss T31 TrussType Hip Qty 1 Ply 1 1802242-12TDWHWoodside-West Clay- 4 Job Reference (optional)Run:8.200 s Apr72018 Print:8.200 s Apr72018MiTekIndustries,Inc.Tue Jun1221:12:272018 Page1ID:bRTO9oDnRLEHvJjVgeMKW3yF_s1-Nv9OP2fzB4MjjbyjOuL7I14IUx_W1SoZlb_iwrz6wG2 Scale=1:99.8 0 -1 -14 0 -1 -14 T2 T3 T2 B1 W1 W2 W3 W4 W5 W6 W7 W6 W7 W6 W5 W4 W3 W2 W1 HW1 T1 T4 T5 B4B3B2 HW2 1 2 3 4 5 6 7 8 9 10 11 12 13 14 25 24 23 22 21 20 19 18 17 16 15 33 34 35 36 37 38 39 40 41 42 5x6 6x6 4x6 4x6 5x12 4x6 4x62x4 2x4 4x8 6x6 2x4 6x84x65x6 5-2-7 5-2-7 10-7-7 5-4-15 16-0-6 5-4-15 23-2-14 7-2-8 30-7-2 7-4-4 37-9-10 7-2-8 43-2-9 5-4-15 48-7-9 5-4-15 54-4-0 5-8-7 5-2-7 5-2-7 10-7-7 5-4-15 16-0-6 5-4-15 23-2-14 7-2-8 30-7-2 7-4-4 37-9-10 7-2-8 43-2-9 5-4-15 48-7-9 5-4-15 54-4-0 5-8-7 1 -1 -0 8 -11 -5 9 -1 -3 0 -10 -0 8 -11 -5 6.0012 PlateOffsets(X,Y)-- [1:0-6-14,Edge], [14:0-0-0,0-1-7] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 10.0 SPACING- PlateGrip DOL Lumber DOL RepStressIncr Code 2-0-0 1.15 1.15 YES IBC2012/TPI2007 CSI. TC BC WB Matrix-MSH 0.66 0.52 0.75 DEFL. Vert(LL) Vert(TL) Horz(TL) in -0.23 -0.55 0.15 (loc) 19-21 19-21 14 l/defl >999 >999 n/a L/d 240 180 n/a PLATES MT20 Weight: 357 lb FT= 20% GRIP 197/144 LUMBER- TOP CHORD2x6SPF No.2BOT CHORD2x6SP 2400F 2.0E WEBS 2x4SPF No.2 *Except* W1,W2,W3: 2x4SPFStudWEDGE Right: 2x4SPFStud SLIDER Left 2x4SPFStud 1-6-0 BRACING- TOP CHORD Structuralwoodsheathing directly applied or 2-9-9 oc purlins.BOT CHORD Rigidceiling directly applied or 10-0-0 oc bracing. WEBS 1 Row at midpt 7-21, 7-19, 9-19 MiTekrecommends that Stabilizers and requiredcross bracing beinstalled during truss erection,in accordancewithStabilizerInstallation guide. REACTIONS.(lb/size)1=2033/Mechanical, 14=2031/0-6-0(min. 0-1-13) Max Horz1=-150(LC 17)Max Uplift1=-207(LC 16), 14=-213(LC 17) MaxGrav1=2173(LC 2), 14=2173(LC 2) FORCES.(lb)-Max. Comp./Max.Ten.-All forces 250 (lb) orless exceptwhenshown. TOP CHORD 1-2=-1509/222, 2-33=-3545/596, 3-33=-3445/618, 3-34=-3596/666, 4-34=-3565/673, 4-35=-3557/675, 5-35=-3526/692, 5-6=-3364/694, 6-36=-3727/740, 7-36=-3730/740, 7-37=-3738/739, 8-37=-3738/739, 8-38=-3738/739, 9-38=-3738/739, 9-39=-3740/740, 10-39=-3738/741, 10-11=-3416/703, 11-40=-3651/712, 12-40=-3678/696, 12-41=-3682/693, 13-41=-3720/685, 13-42=-3778/674, 14-42=-3898/647 BOT CHORD 1-25=-484/3052, 24-25=-484/3052, 23-24=-487/3189, 22-23=-487/3189, 21-22=-367/2994, 20-21=-442/3727, 19-20=-442/3727, 18-19=-363/3043, 17-18=-491/3290, 16-17=-491/3290, 15-16=-525/3384, 14-15=-525/3384 WEBS 3-24=-71/304, 5-22=-642/214, 6-22=-82/597, 6-21=-232/1136, 7-21=-716/267, 9-19=-696/226, 10-19=-227/1077, 10-18=-88/659, 11-18=-712/220, 11-16=-15/285 NOTES- 1) Unbalancedroofliveloads have been considered for this design. 2)Wind:ASCE 7-10;Vult=115mph(3-second gust)Vasd=91mph;TCDL=6.0psf;BCDL=6.0psf; h=25ft; Cat. II;Exp C; enclosed; MWFRS(envelope) gable end zone and C-CExterior(2) 0-0-0 to 5-2-7,Interior(1) 5-2-7 to 16-0-6,Exterior(2) 16-0-6 to 45-5-13,Interior(1) 45-5-13 to 54-4-0zone;cantileverleft and right exposed ; end verticalleft and right exposed;C-C formembers and forces &MWFRS forreactionsshown; Lumber DOL=1.60 plate grip DOL=1.60 3)TCLL:ASCE 7-10;Pr=20.0 psf(roofliveload: Lumber DOL=1.15Plate DOL=1.15);Pg=20.0 psf(groundsnow);Pf=20.4 psf(flatroofsnow: Lumber DOL=1.15Plate DOL=1.15); CategoryII;Exp C; PartiallyExp.; Ct=1.1, Lu=50-0-0;Min. flatroofsnowload governs. Rainsurcharge applied to all exposedsurfaceswithslopesless than 0.500/12 in accordancewithIBC 1608.3.4. 4) Unbalancedsnowloads have been considered for this design.5)Provide adequate drainage to preventwater ponding. 6)All plates are 4x4MT20 unless otherwiseindicated. 7)This truss has been designed for a 10.0 psf bottomchordliveload nonconcurrentwith any otherliveloads. 8) Refer to girder(s) for truss to trussconnections. 9)Providemechanicalconnection(by others) of truss to bearing platecapable of withstanding 100 lb uplift at joint(s) except(jt=lb) 1=207, 14=213.Continued on page 2 DE Job # 59223-W1 Dansco Engineering, LLC Date: 6/13/18 WARNING – VERIFY DESIGN PARAMETERS AND READ NOTES BEFORE FABRICATION AND INSTALLATION!!! This truss design is adequate for the design parameters shown. Review and approval of design parameters is the responsibility of the building designer, not the truss designer or truss engineer. Permanent bracing requirements against out-of-plane buckling are noted/shown for individual truss members (and for the truss as a whole) subjected to gravity and wind loads. Additional permanent bracing design shall be the responsibility of the design professional of record. Temporary and erection bracing shall be the responsibility of the contractor. Reference ANSI/TPI-1, “National Design Standard for Metal Plate Connected Wood Truss Construction” and TPI/WTCA BCSI-06, “Building Component Safety Information Guide to Good Practice for Handling, Installing, Restraining and Bracing of Metal Plate Connected Wood Trusses” for additional information. Job 1802242-12T Truss T31 TrussType Hip Qty 1 Ply 1 1802242-12TDWHWoodside-West Clay- 4 Job Reference (optional)Run:8.200 s Apr72018 Print:8.200 s Apr72018MiTekIndustries,Inc.Tue Jun1221:12:272018 Page2ID:bRTO9oDnRLEHvJjVgeMKW3yF_s1-Nv9OP2fzB4MjjbyjOuL7I14IUx_W1SoZlb_iwrz6wG2 NOTES- 10)This trussis designedin accordancewith the 2012 InternationalBuilding Code section 2306.1 and referencedstandardANSI/TPI 1. LOADCASE(S)Standard DE Job # 59223-W1 Dansco Engineering, LLC Date: 6/13/18 WARNING – VERIFY DESIGN PARAMETERS AND READ NOTES BEFORE FABRICATION AND INSTALLATION!!! This truss design is adequate for the design parameters shown. Review and approval of design parameters is the responsibility of the building designer, not the truss designer or truss engineer. Permanent bracing requirements against out-of-plane buckling are noted/shown for individual truss members (and for the truss as a whole) subjected to gravity and wind loads. Additional permanent bracing design shall be the responsibility of the design professional of record. Temporary and erection bracing shall be the responsibility of the contractor. Reference ANSI/TPI-1, “National Design Standard for Metal Plate Connected Wood Truss Construction” and TPI/WTCA BCSI-06, “Building Component Safety Information Guide to Good Practice for Handling, Installing, Restraining and Bracing of Metal Plate Connected Wood Trusses” for additional information. Job 1802242-12T Truss T32 TrussType Hip Qty 1 Ply 1 1802242-12TDWHWoodside-West Clay- 4 Job Reference (optional)Run:8.200 s Apr72018 Print:8.200 s Apr72018MiTekIndustries,Inc.Tue Jun1221:12:282018 Page1ID:bRTO9oDnRLEHvJjVgeMKW3yF_s1-s5jmdOfbyOUaKlXvycsMqFcYhLKjmrqi_FjGSHz6wG1 Scale=1:98.0 0 -1 -14 0 -1 -14 T1 T2 T4 B1 W1 W2 W3 W4 W5 W4 W5 W4 W5 W4 W3 W2 W1 HW1 T3 B3B1B2 HW2 1 2 3 4 5 6 7 8 9 10 11 21 20 19 18 17 16 15 14 13 12 29 30 31 32 33 34 35 36 37 38 39 5x12 4x6 6x6 4x6 6x64x6 4x4 2x4 4x4 4x6 4x4 4x8 2x4 4x4 4x6 6x6 4x4 4x4 2x44x66x6 6-4-13 6-4-13 13-0-6 6-7-9 19-10-13 6-10-7 26-11-0 7-0-3 33-11-3 7-0-3 40-9-10 6-10-7 47-5-3 6-7-9 54-4-0 6-10-13 6-4-13 6-4-13 13-0-6 6-7-9 19-10-13 6-10-7 26-11-0 7-0-3 33-11-3 7-0-3 40-9-10 6-10-7 47-5-3 6-7-9 54-4-0 6-10-13 1 -1 -0 7 -5 -5 7 -7 -3 0 -10 -0 7 -5 -5 6.0012 PlateOffsets(X,Y)-- [1:0-5-8,Edge], [4:0-3-8,0-3-0], [9:0-3-4,0-3-0] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 10.0 SPACING- PlateGrip DOL Lumber DOL RepStressIncr Code 2-0-0 1.15 1.15 YES IBC2012/TPI2007 CSI. TC BC WB Matrix-MSH 0.38 0.53 0.95 DEFL. Vert(LL) Vert(TL) Horz(TL) in -0.26 -0.59 0.17 (loc) 16 16-18 11 l/defl >999 >999 n/a L/d 240 180 n/a PLATES MT20 Weight: 369 lb FT= 20% GRIP 197/144 LUMBER- TOP CHORD2x6SP 2400F 2.0EBOT CHORD2x6SP 2400F 2.0E WEBS 2x4SPFStud*Except* W2,W4: 2x4SPF No.2WEDGE Right: 2x4SPFStud SLIDER Left 2x4SPFStud 1-6-0 BRACING- TOP CHORD Structuralwoodsheathing directly applied or 4-8-3 oc purlins.BOT CHORD Rigidceiling directly applied or 10-0-0 oc bracing. MiTekrecommends that Stabilizers and requiredcross bracing beinstalled during truss erection,in accordancewithStabilizer Installation guide. REACTIONS.(lb/size)1=2064/Mechanical, 11=2061/0-6-0(min. 0-1-13) Max Horz1=-124(LC 17)Max Uplift1=-221(LC 13), 11=-218(LC 12) MaxGrav1=2173(LC 2), 11=2173(LC 2) FORCES.(lb)-Max. Comp./Max.Ten.-All forces 250 (lb) orless exceptwhenshown. TOP CHORD 1-2=-1596/248, 2-29=-3650/638, 29-30=-3610/661, 3-30=-3521/667, 3-4=-3678/688, 4-31=-4374/796, 5-31=-4376/796, 5-32=-4693/834, 32-33=-4693/834, 6-33=-4693/834, 6-7=-4693/834, 7-34=-4693/834, 8-34=-4693/834, 8-35=-4416/802, 9-35=-4414/803, 9-10=-3766/707, 10-36=-3794/712, 36-37=-3806/707, 37-38=-3820/695, 38-39=-3904/685, 11-39=-3944/680 BOT CHORD 1-21=-527/3141, 20-21=-527/3141, 19-20=-426/3297, 18-19=-426/3297, 17-18=-565/4374, 16-17=-565/4374, 15-16=-551/4413, 14-15=-426/3366, 13-14=-426/3366, 12-13=-563/3417, 11-12=-563/3417 WEBS 3-20=-346/299, 4-20=-21/365, 4-18=-304/1542, 5-18=-982/304, 5-16=-117/509, 6-16=-455/195, 8-16=-113/458, 8-15=-946/301, 9-15=-300/1499, 9-13=-31/454, 10-13=-535/220 NOTES- 1) Unbalancedroofliveloads have been considered for this design. 2)Wind:ASCE 7-10;Vult=115mph(3-second gust)Vasd=91mph;TCDL=6.0psf;BCDL=6.0psf; h=25ft; Cat. II;Exp C; enclosed;MWFRS(envelope) gable end zone and C-CExterior(2) 0-0-0 to 5-5-3,Interior(1) 5-5-3 to 13-0-6,Exterior(2) 13-0-6 to 48-5-13, Interior(1) 48-5-13 to 54-4-0zone;cantileverleft and right exposed ; end verticalleft and right exposed;C-C formembers and forces &MWFRS forreactionsshown; Lumber DOL=1.60 plate grip DOL=1.603)TCLL:ASCE 7-10;Pr=20.0 psf(roofliveload: Lumber DOL=1.15Plate DOL=1.15);Pg=20.0 psf(groundsnow);Pf=20.4 psf(flat roofsnow: Lumber DOL=1.15Plate DOL=1.15); CategoryII;Exp C; PartiallyExp.; Ct=1.1, Lu=50-0-0;Min. flatroofsnowload governs. Rainsurcharge applied to all exposedsurfaceswithslopesless than 0.500/12 in accordancewithIBC 1608.3.4.4) Unbalancedsnowloads have been considered for this design. 5)Provide adequate drainage to preventwater ponding. 6)This truss has been designed for a 10.0 psf bottomchordliveload nonconcurrentwith any otherliveloads. 7) Refer to girder(s) for truss to trussconnections. 8)Providemechanicalconnection(by others) of truss to bearing platecapable of withstanding 100 lb uplift at joint(s) except(jt=lb) 1=221, 11=218.Continued on page 2 DE Job # 59223-W1 Dansco Engineering, LLC Date: 6/13/18 WARNING – VERIFY DESIGN PARAMETERS AND READ NOTES BEFORE FABRICATION AND INSTALLATION!!! This truss design is adequate for the design parameters shown. Review and approval of design parameters is the responsibility of the building designer, not the truss designer or truss engineer. Permanent bracing requirements against out-of-plane buckling are noted/shown for individual truss members (and for the truss as a whole) subjected to gravity and wind loads. Additional permanent bracing design shall be the responsibility of the design professional of record. Temporary and erection bracing shall be the responsibility of the contractor. Reference ANSI/TPI-1, “National Design Standard for Metal Plate Connected Wood Truss Construction” and TPI/WTCA BCSI-06, “Building Component Safety Information Guide to Good Practice for Handling, Installing, Restraining and Bracing of Metal Plate Connected Wood Trusses” for additional information. Job 1802242-12T Truss T32 TrussType Hip Qty 1 Ply 1 1802242-12TDWHWoodside-West Clay- 4 Job Reference (optional)Run:8.200 s Apr72018 Print:8.200 s Apr72018MiTekIndustries,Inc.Tue Jun1221:12:282018 Page2ID:bRTO9oDnRLEHvJjVgeMKW3yF_s1-s5jmdOfbyOUaKlXvycsMqFcYhLKjmrqi_FjGSHz6wG1 NOTES- 9)This trussis designedin accordancewith the 2012 InternationalBuilding Code section 2306.1 and referencedstandardANSI/TPI 1. LOADCASE(S)Standard DE Job # 59223-W1 Dansco Engineering, LLC Date: 6/13/18 WARNING – VERIFY DESIGN PARAMETERS AND READ NOTES BEFORE FABRICATION AND INSTALLATION!!! This truss design is adequate for the design parameters shown. Review and approval of design parameters is the responsibility of the building designer, not the truss designer or truss engineer. Permanent bracing requirements against out-of-plane buckling are noted/shown for individual truss members (and for the truss as a whole) subjected to gravity and wind loads. Additional permanent bracing design shall be the responsibility of the design professional of record. Temporary and erection bracing shall be the responsibility of the contractor. Reference ANSI/TPI-1, “National Design Standard for Metal Plate Connected Wood Truss Construction” and TPI/WTCA BCSI-06, “Building Component Safety Information Guide to Good Practice for Handling, Installing, Restraining and Bracing of Metal Plate Connected Wood Trusses” for additional information. Job 1802242-12T Truss T33 TrussType Hip Qty 1 Ply 1 1802242-12TDWHWoodside-West Clay- 4 Job Reference (optional)Run:8.200 s Apr72018 Print:8.200 s Apr72018MiTekIndustries,Inc.Tue Jun1221:12:302018 Page1ID:bRTO9oDnRLEHvJjVgeMKW3yF_s1-oUqX24hrU?kHa3hI30uqvgiw792BEoh?RZCNXAz6wG? Scale:1/8"=1' 0 -1 -14 0 -1 -14 T1 T2 T5 B1 W1 W2 W3 W4 W5 W4 W5 W4 W5 W4 W5 W4 W5 W4 W3 W2 W1 HW1 T4T3 B4B3B2 1 2 3 4 5 6 7 8 9 10 11 12 13 25 24 23 22 21 20 19 18 17 16 15 14 32 33 34 35 36 37 38 39 8x8 6x8 5x86x8 4x4 3x6 5x6 4x8 3x6 5x6 8x8 4x4 3x68x8 6x8 6x8 8x8 4-10-15 4-10-15 10-0-6 5-1-7 15-6-12 5-6-6 21-2-14 5-8-2 26-11-0 5-8-2 32-7-2 5-8-2 38-3-4 5-8-2 43-9-10 5-6-6 48-11-1 5-1-7 54-4-0 5-4-15 4-10-15 4-10-15 10-0-6 5-1-7 15-6-12 5-6-6 21-2-14 5-8-2 26-11-0 5-8-2 32-7-2 5-8-2 38-3-4 5-8-2 43-9-10 5-6-6 48-11-1 5-1-7 54-4-0 5-4-15 1 -1 -0 5 -11 -5 6 -1 -3 0 -10 -0 5 -11 -5 6.0012 PlateOffsets(X,Y)-- [1:0-8-2,0-0-6], [1:0-0-6,0-0-3], [3:0-4-12,0-3-0], [11:0-6-0,0-3-4] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 10.0 SPACING- PlateGrip DOL Lumber DOL RepStressIncr Code 2-0-0 1.15 1.15 YES IBC2012/TPI2007 CSI. TC BC WB Matrix-MSH 0.19 0.33 0.74 DEFL. Vert(LL) Vert(TL) Horz(TL) in -0.30 -0.67 0.15 (loc) 19 19 13 l/defl >999 >970 n/a L/d 240 180 n/a PLATES MT20 Weight: 433 lb FT= 20% GRIP 197/144 LUMBER- TOP CHORD2x8SP 2400F 2.0E*Except*T1,T5: 2x6SP 2400F 2.0E BOT CHORD2x8SP 2400F 2.0E WEBS 2x4SPFStud*Except*W4: 2x4SPF No.2 WEDGE Left: 2x6SPF No.2 BRACING- TOP CHORD Structuralwoodsheathing directly applied or 4-10-1 oc purlins.BOT CHORD Rigidceiling directly applied or 10-0-0 oc bracing. MiTekrecommends that Stabilizers and requiredcross bracing beinstalled during truss erection,in accordancewithStabilizer Installation guide. REACTIONS.(lb/size)13=2091/0-6-0(min. 0-1-13), 1=2094/Mechanical Max Horz1=-97(LC 17)Max Uplift13=-276(LC 12), 1=-280(LC 13) MaxGrav13=2173(LC 2), 1=2173(LC 2) FORCES.(lb)-Max. Comp./Max.Ten.-All forces 250 (lb) orless exceptwhenshown. TOP CHORD 1-32=-3582/633, 2-32=-3560/654, 2-33=-3928/679, 3-33=-3927/703, 3-34=-4973/864, 4-34=-4978/863, 4-35=-5760/965, 5-35=-5760/965, 5-36=-5979/996, 6-36=-5979/996, 6-7=-5979/996, 7-37=-5979/996, 8-37=-5979/996, 8-9=-5801/969, 9-10=-5801/969, 10-38=-5063/874, 11-38=-5058/875, 11-12=-4065/729, 12-39=-3892/717, 13-39=-3949/694 BOT CHORD 1-25=-529/3126, 24-25=-529/3126, 23-24=-516/3533, 22-23=-516/3533, 21-22=-756/4972, 20-21=-894/5760, 19-20=-894/5760, 18-19=-865/5801, 17-18=-704/5056, 16-17=-483/3648, 15-16=-483/3648, 14-15=-578/3475, 13-14=-578/3475 WEBS 2-25=-341/127, 2-24=-132/475, 3-24=-13/254, 3-22=-387/2022, 4-22=-1347/347, 4-21=-235/1082, 5-21=-627/226, 5-19=-90/403, 7-19=-335/160, 8-19=-85/350, 8-18=-589/222, 10-18=-228/1027, 10-17=-1310/343, 11-17=-382/1980, 11-15=-21/342, 12-15=-303/258 NOTES- 1) Unbalancedroofliveloads have been considered for this design.2)Wind:ASCE 7-10;Vult=115mph(3-second gust)Vasd=91mph;TCDL=6.0psf;BCDL=6.0psf; h=25ft; Cat. II;Exp C; enclosed; MWFRS(envelope) gable end zone and C-CExterior(2) 0-0-0 to 5-5-3,Interior(1) 5-5-3 to 10-0-6,Exterior(2) 10-0-6 to 51-5-13, Interior(1) 51-5-13 to 54-4-0zone;cantileverleft and right exposed ; end verticalleft and right exposed;C-C formembers and forces&MWFRS forreactionsshown; Lumber DOL=1.60 plate grip DOL=1.60 3)TCLL:ASCE 7-10;Pr=20.0 psf(roofliveload: Lumber DOL=1.15Plate DOL=1.15);Pg=20.0 psf(groundsnow);Pf=20.4 psf(flat roofsnow: Lumber DOL=1.15Plate DOL=1.15); CategoryII;Exp C; PartiallyExp.; Ct=1.1, Lu=50-0-0;Min. flatroofsnowloadgoverns. Rainsurcharge applied to all exposedsurfaceswithslopesless than 0.500/12 in accordancewithIBC 1608.3.4. 4) Unbalancedsnowloads have been considered for this design. 5)Provide adequate drainage to preventwater ponding. 6)All plates are 4x6MT20 unless otherwiseindicated. 7)This truss has been designed for a 10.0 psf bottomchordliveload nonconcurrentwith any otherliveloads. 8) Refer to girder(s) for truss to trussconnections.Continued on page 2 DE Job # 59223-W1 Dansco Engineering, LLC Date: 6/13/18 WARNING – VERIFY DESIGN PARAMETERS AND READ NOTES BEFORE FABRICATION AND INSTALLATION!!! This truss design is adequate for the design parameters shown. Review and approval of design parameters is the responsibility of the building designer, not the truss designer or truss engineer. Permanent bracing requirements against out-of-plane buckling are noted/shown for individual truss members (and for the truss as a whole) subjected to gravity and wind loads. Additional permanent bracing design shall be the responsibility of the design professional of record. Temporary and erection bracing shall be the responsibility of the contractor. Reference ANSI/TPI-1, “National Design Standard for Metal Plate Connected Wood Truss Construction” and TPI/WTCA BCSI-06, “Building Component Safety Information Guide to Good Practice for Handling, Installing, Restraining and Bracing of Metal Plate Connected Wood Trusses” for additional information. Job 1802242-12T Truss T33 TrussType Hip Qty 1 Ply 1 1802242-12TDWHWoodside-West Clay- 4 Job Reference (optional)Run:8.200 s Apr72018 Print:8.200 s Apr72018MiTekIndustries,Inc.Tue Jun1221:12:302018 Page2ID:bRTO9oDnRLEHvJjVgeMKW3yF_s1-oUqX24hrU?kHa3hI30uqvgiw792BEoh?RZCNXAz6wG? NOTES- 9)Providemechanicalconnection(by others) of truss to bearing platecapable of withstanding 100 lb uplift at joint(s) except(jt=lb) 13=276, 1=280. 10)This trussis designedin accordancewith the 2012 InternationalBuilding Code section 2306.1 and referencedstandardANSI/TPI 1. LOADCASE(S)Standard DE Job # 59223-W1 Dansco Engineering, LLC Date: 6/13/18 WARNING – VERIFY DESIGN PARAMETERS AND READ NOTES BEFORE FABRICATION AND INSTALLATION!!! This truss design is adequate for the design parameters shown. Review and approval of design parameters is the responsibility of the building designer, not the truss designer or truss engineer. Permanent bracing requirements against out-of-plane buckling are noted/shown for individual truss members (and for the truss as a whole) subjected to gravity and wind loads. Additional permanent bracing design shall be the responsibility of the design professional of record. Temporary and erection bracing shall be the responsibility of the contractor. Reference ANSI/TPI-1, “National Design Standard for Metal Plate Connected Wood Truss Construction” and TPI/WTCA BCSI-06, “Building Component Safety Information Guide to Good Practice for Handling, Installing, Restraining and Bracing of Metal Plate Connected Wood Trusses” for additional information. Job 1802242-12T Truss T34 TrussType HipGirder Qty 1 Ply 3 1802242-12TDWHWoodside-West Clay- 4 Job Reference (optional)Run:8.200 s Apr72018 Print:8.200 s Apr72018MiTekIndustries,Inc.Tue Jun1221:12:422018 Page1ID:bRTO9oDnRLEHvJjVgeMKW3yF_s1-RnZ3ZAqNfhFa0vccmY6ePCC?V_CD2H9mCR7?xTz6wFp Scale:1/8"=1' 0 -1 -14 0 -1 -14 T1 T2 T4 B1 W1 W2 W3 W4 W5 W4 W5 W4 W5 W4 W5 W4 W5 W4 W5 W4 W5 W4 W3 W2 W1HW1 T3T2 B4B3B2 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 29 28 27 26 25 24 23 22 21 20 19 18 17 16 36 37 38 39 40 41 4243 4445 46 47 48 49 50 51 52 53 54 55 56 57 58 59 6061 62 63 64 65 66 67 68 69 70 71 72 73 74 75 8x8 6x8 5x86x8 4x4 3x6 4x8 3x6 8x8 4x4 3x65x8 6x8 6x86x8 3-4-5 3-4-5 6-7-14 3-3-9 11-7-6 4-11-8 16-8-9 5-1-4 21-9-13 5-1-4 26-11-0 5-1-4 32-0-4 5-1-4 37-1-7 5-1-4 42-2-11 5-1-4 47-2-2 4-11-8 50-5-11 3-3-9 54-4-0 3-10-5 3-4-5 3-4-5 6-7-14 3-3-9 11-7-6 4-11-8 16-8-9 5-1-4 21-9-13 5-1-4 26-11-0 5-1-4 32-0-4 5-1-4 37-1-7 5-1-4 42-2-11 5-1-4 47-2-2 4-11-8 50-5-11 3-3-9 54-4-0 3-10-5 1 -1 -0 4 -3 -1 4 -4 -15 0 -10 -0 4 -3 -1 6.0012 PlateOffsets(X,Y)-- [1:0-0-6,0-5-7], [1:0-0-3,0-0-6], [3:0-4-0,0-3-4], [13:0-4-0,0-3-4] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 10.0 SPACING- PlateGrip DOL Lumber DOL RepStressIncr Code 2-0-0 1.15 1.15 NO IBC2012/TPI2007 CSI. TC BC WB Matrix-MSH 0.10 0.19 0.51 DEFL. Vert(LL) Vert(TL) Horz(TL) in 0.39 -0.58 0.09 (loc) 22 22 15 l/defl >999 >999 n/a L/d 240 180 n/a PLATES MT20 Weight: 1276 lbFT= 20% GRIP 197/144 LUMBER- TOP CHORD2x8SP 2400F 2.0E*Except*T1,T4: 2x6SP 2400F 2.0E BOT CHORD2x8SP 2400F 2.0E WEBS 2x4SPFStudWEDGE Left: 2x4SPFStud BRACING- TOP CHORD Structuralwoodsheathing directly applied or 6-0-0 oc purlins.BOT CHORD Rigidceiling directly applied or 10-0-0 oc bracing. REACTIONS.(lb/size)15=2984/0-6-0(min. 0-1-8), 1=3048/Mechanical Max Horz1=-67(LC 13) Max Uplift15=-1518(LC 8), 1=-1610(LC 9)MaxGrav15=3184(LC 2), 1=3258(LC 2) FORCES.(lb)-Max. Comp./Max.Ten.-All forces 250 (lb) orless exceptwhenshown. TOP CHORD 1-2=-4939/2535, 2-3=-5873/3134, 3-36=-8140/4429, 36-37=-8144/4430, 37-38=-8144/4430, 38-39=-8147/4432, 4-39=-8150/4433, 4-40=-10242/5570, 40-41=-10242/5570, 5-41=-10242/5570, 5-42=-11496/6249, 42-43=-11496/6249, 43-44=-11496/6249, 6-44=-11496/6249, 6-45=-11496/6249, 7-45=-11496/6249, 7-46=-11924/6466, 46-47=-11924/6466, 8-47=-11924/6466, 8-48=-11924/6466, 48-49=-11924/6466, 9-49=-11924/6466, 9-50=-11554/6257, 10-50=-11554/6257, 10-51=-11554/6257, 11-51=-11554/6257, 11-52=-10363/5594, 52-53=-10363/5594, 12-53=-10363/5594, 12-54=-8333/4470, 54-55=-8330/4468, 13-55=-8327/4467, 13-56=-6127/3198, 14-56=-6168/3213, 14-15=-5613/2793 BOT CHORD 1-29=-2200/4244, 28-29=-2200/4244, 28-57=-2845/5334, 57-58=-2845/5334, 58-59=-2845/5334, 27-59=-2845/5334, 27-60=-4390/8144, 26-60=-4390/8144, 26-61=-4390/8144, 25-61=-4390/8144, 25-62=-5532/10242, 62-63=-5532/10242, 63-64=-5532/10242, 24-64=-5532/10242, 24-65=-6211/11496, 23-65=-6211/11496,23-66=-6211/11496, 22-66=-6211/11496, 22-67=-6210/11554, 67-68=-6210/11554, 21-68=-6210/11554, 21-69=-5537/10363, 69-70=-5537/10363, 20-70=-5537/10363, 19-20=-4399/8327, 19-71=-4399/8327, 71-72=-4399/8327, 18-72=-4399/8327,18-73=-2861/5568, 73-74=-2861/5568, 17-74=-2861/5568, 17-75=-2426/4907, 16-75=-2426/4907, 15-16=-2426/4907 WEBS 2-29=-883/545, 2-28=-809/1469, 3-28=-200/281, 3-27=-1955/3602, 4-27=-2096/1252,4-25=-1416/2587, 5-25=-1337/836, 5-24=-846/1551, 7-24=-734/505, 7-22=-277/535, 8-22=-416/335, 9-22=-268/465, 9-21=-690/495, 11-21=-827/1474, 11-20=-1294/828, 12-20=-1399/2511, 12-18=-2050/1236, 13-18=-1934/3550, 13-17=-3/250, 14-17=-556/996, 14-16=-573/388 Continued on page 2 DE Job # 59223-W1 Dansco Engineering, LLC Date: 6/13/18 WARNING – VERIFY DESIGN PARAMETERS AND READ NOTES BEFORE FABRICATION AND INSTALLATION!!! This truss design is adequate for the design parameters shown. Review and approval of design parameters is the responsibility of the building designer, not the truss designer or truss engineer. Permanent bracing requirements against out-of-plane buckling are noted/shown for individual truss members (and for the truss as a whole) subjected to gravity and wind loads. Additional permanent bracing design shall be the responsibility of the design professional of record. Temporary and erection bracing shall be the responsibility of the contractor. Reference ANSI/TPI-1, “National Design Standard for Metal Plate Connected Wood Truss Construction” and TPI/WTCA BCSI-06, “Building Component Safety Information Guide to Good Practice for Handling, Installing, Restraining and Bracing of Metal Plate Connected Wood Trusses” for additional information. Job 1802242-12T Truss T34 TrussType HipGirder Qty 1 Ply 3 1802242-12TDWHWoodside-West Clay- 4 Job Reference (optional)Run:8.200 s Apr72018 Print:8.200 s Apr72018MiTekIndustries,Inc.Tue Jun1221:12:422018 Page2ID:bRTO9oDnRLEHvJjVgeMKW3yF_s1-RnZ3ZAqNfhFa0vccmY6ePCC?V_CD2H9mCR7?xTz6wFp NOTES- 1) 3-ply truss to be connected togetherwith 10d (0.131"x3") nails as follows: Topchordsconnected as follows: 2x6- 2 rowsstaggered at 0-9-0 oc, 2x8- 2 rowsstaggered at 0-9-0 oc. Bottomchordsconnected as follows: 2x8- 2 rowsstaggered at 0-9-0 oc.Websconnected as follows: 2x4- 1 row at 0-9-0 oc. 2)Allloads areconsidered equally applied to all plies, exceptif noted as front(F) or back(B) facein the LOAD CASE(S)section.Ply to plyconnections have been provided to distribute onlyloads noted as(F) or(B), unless otherwiseindicated. 3) Unbalancedroofliveloads have been considered for this design. 4)Wind:ASCE 7-10;Vult=115mph(3-second gust)Vasd=91mph;TCDL=6.0psf;BCDL=6.0psf; h=25ft; Cat. II;Exp C; enclosed;MWFRS(envelope) gable end zone; cantileverleft and right exposed ; end verticalleft and right exposed; Lumber DOL=1.60 plate grip DOL=1.60 5)TCLL:ASCE 7-10;Pr=20.0 psf(roofliveload: Lumber DOL=1.15Plate DOL=1.15);Pg=20.0 psf(groundsnow);Pf=20.4 psf(flatroofsnow: Lumber DOL=1.15Plate DOL=1.15); CategoryII;Exp C; PartiallyExp.; Ct=1.1, Lu=50-0-0 Rainsurcharge applied to all exposedsurfaceswithslopesless than 0.500/12 in accordancewithIBC 1608.3.4.6) Unbalancedsnowloads have been considered for this design. 7)Provide adequate drainage to preventwater ponding. 8)All plates are 4x6MT20 unless otherwiseindicated. 9)This truss has been designed for a 10.0 psf bottomchordliveload nonconcurrentwith any otherliveloads. 10) Refer to girder(s) for truss to trussconnections. 11)Providemechanicalconnection(by others) of truss to bearing platecapable of withstanding 100 lb uplift at joint(s) except(jt=lb) 15=1518, 1=1610. 12)This trussis designedin accordancewith the 2012 InternationalBuilding Code section 2306.1 and referencedstandardANSI/TPI 1. 13) Hanger(s) or otherconnection device(s)shall be providedsufficient to supportconcentratedload(s) 98 lb down and 116 lb up at 3-5-0, 266 lb down and 313 lb up at 6-7-14, 110 lb down and 113 lb up at 7-1-6, 115 lb down and 113 lb up at 9-1-6, 115 lb down and 113 lb up at 11-1-6, 115 lb down and 113 lb up at 13-1-6, 115 lb down and 113 lb up at 15-1-6, 115 lb down and 113 lb up at 17-1-6, 115 lb down and 113 lb up at 19-1-6, 115 lb down and 113 lb up at 21-1-6, 115 lb down and 113 lb up at 23-1-6, 115 lb down and 113 lb up at 25-1-6, 115 lb down and 113 lb up at 27-1-6, 115 lb down and 113 lb up at 29-1-6, 115 lb down and 113 lb up at 31-1-6, 115 lb down and 113 lb up at 33-1-6, 115 lb down and 113 lb up at 35-1-6, 115 lb down and 113 lb up at 37-1-6, 115 lb down and 113 lb up at 39-1-6, 115 lb down and 113 lb up at 41-1-6, 115 lb down and 113 lb up at 43-1-6, 115 lb down and 113 lb up at 45-1-6, and 266 lb down and 312 lb up at 47-2-2, and 110 lb down and 123 lb up at 49-6-2 on top chord, and 37 lb down at 3-5-0, 121 lb down and 9 lb up at 6-7-14, 41 lb down and 26 lb up at 7-1-6, 41 lb down and 26 lb up at 9-1-6, 41 lb down and 26 lb up at 11-1-6, 41 lb down and 26 lb up at 13-1-6, 41 lb down and 26 lb up at 15-1-6, 41 lb down and 26 lb up at 17-1-6, 41 lb down and 26 lb up at 19-1-6, 41 lb down and 26 lb up at 21-1-6, 41 lb down and 26 lb up at 23-1-6, 41 lb down and 26 lb up at 25-1-6, 41 lb down and 26 lb up at 27-1-6, 41 lb down and 26 lb up at 29-1-6, 41lb down and 26 lb up at 31-1-6, 41 lb down and 26 lb up at 33-1-6, 41 lb down and 26 lb up at 35-1-6, 41 lb down and 26 lb up at 37-1-6, 41 lb down and 26 lb up at 39-1-6, 41 lb down and 26 lb up at 41-1-6, 41 lb down and 26 lb up at 43-1-6, 41 lb down and 26 lb up at 45-1-6, and 121 lb down and 10 lb up at 47-1-6, and 33 lb down at 49-6-2 on bottomchord.The design/selection of suchconnection device(s)is the responsibility of others. LOADCASE(S)Standard 1) Dead +Snow(balanced): LumberIncrease=1.15,PlateIncrease=1.15Uniform Loads(plf) Vert: 1-3=-51, 3-13=-61, 13-15=-51, 30-33=-20 Concentrated Loads(lb)Vert: 3=-169(F) 2=-43(F) 29=-23(F) 28=-85(F) 22=-24(F) 8=-33(F) 11=-33(F) 20=-24(F) 13=-168(F) 17=-84(F) 36=-36(F) 38=-33(F) 39=-33(F) 40=-33(F) 41=-33(F) 42=-33(F) 44=-33(F) 45=-33(F) 46=-33(F) 47=-33(F) 48=-33(F) 49=-33(F) 50=-33(F) 51=-33(F) 52=-33(F) 53=-33(F) 54=-33(F) 55=-33(F) 56=-39(F) 57=-24(F) 58=-24(F) 59=-24(F) 60=-24(F) 61=-24(F) 62=-24(F) 63=-24(F) 64=-24(F) 65=-24(F) 66=-24(F) 67=-24(F) 68=-24(F) 69=-24(F) 70=-24(F) 71=-24(F) 72=-24(F) 73=-24(F) 74=-24(F) 75=-23(F) DE Job # 59223-W1 Dansco Engineering, LLC Date: 6/13/18 WARNING – VERIFY DESIGN PARAMETERS AND READ NOTES BEFORE FABRICATION AND INSTALLATION!!! This truss design is adequate for the design parameters shown. Review and approval of design parameters is the responsibility of the building designer, not the truss designer or truss engineer. Permanent bracing requirements against out-of-plane buckling are noted/shown for individual truss members (and for the truss as a whole) subjected to gravity and wind loads. Additional permanent bracing design shall be the responsibility of the design professional of record. Temporary and erection bracing shall be the responsibility of the contractor. Reference ANSI/TPI-1, “National Design Standard for Metal Plate Connected Wood Truss Construction” and TPI/WTCA BCSI-06, “Building Component Safety Information Guide to Good Practice for Handling, Installing, Restraining and Bracing of Metal Plate Connected Wood Trusses” for additional information. Job 1802242-12T Truss T35 TrussType HalfHipGirder Qty 1 Ply 2 1802242-12TDWHWoodside-West Clay- 4 Job Reference (optional)Run:8.200 s Apr72018 Print:8.200 s Apr72018MiTekIndustries,Inc.Tue Jun1221:12:472018 Page1ID:bRTO9oDnRLEHvJjVgeMKW3yF_s1-olMycuuWUDtt6gUZZ5ip6FvpF?t5jSgVMiqmchz6wFk Scale=1:62.4 0 -1 -10 T1 T2 W3 B1 W1 W2 W3 W2 W3 W2 W3 W2 W3 W2 W3 W2 T3 B3B2HW112 3 4 5 6 7 8 9 10 11 20 19 18 17 16 15 14 13 12 25 26 27 28 29 3031 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 6x6 4x6 4x8 3x6 3x10MT18H 4x4 5x62x44x10 2x4 3x8 2x4 2x4 3x8 2x4 3x8 2x4 5x12 5x6 4-6-0 4-6-0 9-3-15 4-9-15 14-3-9 4-11-11 19-3-4 4-11-11 24-2-15 4-11-11 29-2-9 4-11-11 34-4-0 5-1-7 -1-2-12 1-2-12 4-6-0 4-6-0 9-3-15 4-9-15 14-3-9 4-11-11 19-3-4 4-11-11 24-2-15 4-11-11 29-2-9 4-11-11 34-4-0 5-1-7 1 -0 -92-9 -7 2 -11 -1 2 -9 -7 5.0012 PlateOffsets(X,Y)-- [2:0-6-6,0-0-4] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 10.0 SPACING- PlateGrip DOL Lumber DOL RepStressIncr Code 2-0-0 1.15 1.15 NO IBC2012/TPI2007 CSI. TC BC WB Matrix-MSH 0.23 0.27 0.88 DEFL. Vert(LL) Vert(TL) Horz(TL) in 0.33 -0.49 0.07 (loc) 15-18 15-18 12 l/defl >999 >844 n/a L/d 240 180 n/a PLATES MT20 MT18H Weight: 432 lb FT= 20% GRIP 197/144 197/144 LUMBER- TOP CHORD2x6SP 2400F 2.0EBOT CHORD2x6SP 2400F 2.0E WEBS 2x4SPFStud SLIDER Left 2x4SPFStud 1-6-0 BRACING- TOP CHORD Structuralwoodsheathing directly applied or 6-0-0 oc purlins,except end verticals. BOT CHORD Rigidceiling directly applied or 10-0-0 oc bracing. REACTIONS.(lb/size)12=1855/0-6-0(min. 0-1-8), 2=1885/0-4-0(min. 0-1-8) Max Horz2=91(LC 12)Max Uplift12=-1083(LC 8), 2=-1040(LC 8) MaxGrav12=2057(LC 31), 2=1991(LC 2) FORCES.(lb)-Max. Comp./Max.Ten.-All forces 250 (lb) orless exceptwhenshown. TOP CHORD 2-3=-2011/1070, 3-4=-3560/1902, 4-25=-6013/3224, 25-26=-6012/3224, 26-27=-6013/3224, 5-27=-6015/3225, 5-28=-6012/3223, 28-29=-6012/3223, 6-29=-6012/3223, 6-30=-7328/3961, 30-31=-7328/3961, 31-32=-7328/3961, 7-32=-7328/3961, 7-8=-7328/3961, 8-33=-7328/3961, 33-34=-7328/3961, 9-34=-7328/3961, 9-35=-3783/2018, 35-36=-3783/2018, 36-37=-3783/2018, 10-37=-3783/2018, 10-38=-3783/2018, 38-39=-3783/2018, 11-39=-3783/2018, 11-12=-1959/1034 BOT CHORD 2-20=-1738/3213, 20-40=-1744/3222, 40-41=-1744/3222, 19-41=-1744/3222, 19-42=-3923/7295, 42-43=-3923/7295, 18-43=-3923/7295, 17-18=-3923/7295, 17-44=-3923/7295, 16-44=-3923/7295, 15-16=-3923/7295, 15-45=-3331/6204, 45-46=-3331/6204, 14-46=-3331/6204, 14-47=-3331/6204, 47-48=-3331/6204, 48-49=-3331/6204, 13-49=-3331/6204 WEBS 4-19=-1649/3110, 5-19=-561/292, 6-19=-1416/773, 6-18=-69/273, 7-15=-400/236, 9-15=-695/1242, 9-14=-79/283, 9-13=-2673/1450, 10-13=-474/247, 11-13=-2184/4093 NOTES- 1) 2-ply truss to be connected togetherwith 10d (0.131"x3") nails as follows: Topchordsconnected as follows: 2x6- 2 rowsstaggered at 0-9-0 oc, 2x4- 1 row at 0-9-0 oc.Bottomchordsconnected as follows: 2x6- 2 rowsstaggered at 0-9-0 oc. Websconnected as follows: 2x4- 1 row at 0-9-0 oc. 2)Allloads areconsidered equally applied to all plies, exceptif noted as front(F) or back(B) facein the LOAD CASE(S)section.Ply toplyconnections have been provided to distribute onlyloads noted as(F) or(B), unless otherwiseindicated. 3) Unbalancedroofliveloads have been considered for this design. 4)Wind:ASCE 7-10;Vult=115mph(3-second gust)Vasd=91mph;TCDL=6.0psf;BCDL=6.0psf; h=25ft; Cat. II;Exp C; enclosed;MWFRS(envelope) gable end zone;cantileverleft exposed ; end verticalleft exposed; porchleft and right exposed; Lumber DOL=1.60 plate grip DOL=1.60 5)TCLL:ASCE 7-10;Pr=20.0 psf(roofliveload: Lumber DOL=1.15Plate DOL=1.15);Pg=20.0 psf(groundsnow);Pf=20.4 psf(flat roofsnow: Lumber DOL=1.15Plate DOL=1.15); CategoryII;Exp C; PartiallyExp.; Ct=1.1, Lu=50-0-0;Min. flatroofsnowload governs. Rainsurcharge applied to all exposedsurfaceswithslopesless than 0.500/12 in accordancewithIBC 1608.3.4. 6) Unbalancedsnowloads have been considered for this design.Continued on page 2 DE Job # 59223-W1 Dansco Engineering, LLC Date: 6/13/18 WARNING – VERIFY DESIGN PARAMETERS AND READ NOTES BEFORE FABRICATION AND INSTALLATION!!! This truss design is adequate for the design parameters shown. Review and approval of design parameters is the responsibility of the building designer, not the truss designer or truss engineer. Permanent bracing requirements against out-of-plane buckling are noted/shown for individual truss members (and for the truss as a whole) subjected to gravity and wind loads. Additional permanent bracing design shall be the responsibility of the design professional of record. Temporary and erection bracing shall be the responsibility of the contractor. Reference ANSI/TPI-1, “National Design Standard for Metal Plate Connected Wood Truss Construction” and TPI/WTCA BCSI-06, “Building Component Safety Information Guide to Good Practice for Handling, Installing, Restraining and Bracing of Metal Plate Connected Wood Trusses” for additional information. Job 1802242-12T Truss T35 TrussType HalfHipGirder Qty 1 Ply 2 1802242-12TDWHWoodside-West Clay- 4 Job Reference (optional)Run:8.200 s Apr72018 Print:8.200 s Apr72018MiTekIndustries,Inc.Tue Jun1221:12:482018 Page2ID:bRTO9oDnRLEHvJjVgeMKW3yF_s1-GxwKpEv8FX?kkq3l7oD2eTR_?PDKSvvfaMaJ97z6wFj NOTES- 7)This truss has been designed for greater of minroofliveload of 12.0 psf or 2.00 times flatroofload of 15.4 psf on overhangs non-concurrentwith otherliveloads. 8)Provide adequate drainage to preventwater ponding. 9)All plates areMT20 plates unless otherwiseindicated.10)This truss has been designed for a 10.0 psf bottomchordliveload nonconcurrentwith any otherliveloads. 11)Providemechanicalconnection(by others) of truss to bearing platecapable of withstanding 100 lb uplift at joint(s) except(jt=lb) 12=1083, 2=1040. 12)This trussis designedin accordancewith the 2012 InternationalBuilding Code section 2306.1 and referencedstandardANSI/TPI 1. 13) Hanger(s) or otherconnection device(s)shall be providedsufficient to supportconcentratedload(s) 160 lb down and 178 lb up at 4-6-0, 66 lb down and 77 lb up at 6-6-12, 66 lb down and 77 lb up at 8-6-12, 66 lb down and 77 lb up at 10-6-12, 66 lb down and 77 lb up at 12-6-12, 66 lb down and 77 lb up at 14-6-12, 66 lb down and 77lb up at 16-6-12, 66 lb down and 77 lb up at 18-6-12, 66 lb down and 77 lb up at 20-6-12, 66 lb down and 77 lb up at 22-6-12, 66 lb down and 77 lb up at 24-6-12, 66lb down and 77 lb up at 26-6-12, 66 lb down and 77 lb up at 28-6-12, and 66 lb down and 77 lb up at 30-6-12, and 66 lb down and 77 lb up at 32-6-12 on top chord, and 88 lb down and 73 lb up at 4-6-0, 37 lb down and 44 lb up at 6-6-12, 37 lb down and 44 lb up at 8-6-12, 37 lb down and 44 lb up at 10-6-12, 37 lb down and 44 lb up at 12-6-12, 37 lb down and 44 lb up at 14-6-12, 37 lb down and 44 lb up at 16-6-12, 37 lb down and 44 lb up at 18-6-12, 37 lb down and 44 lb up at 20-6-12, 37 lbdown and 44 lb up at 22-6-12, 37 lb down and 44 lb up at 24-6-12, 37 lb down and 44 lb up at 26-6-12, 37 lb down and 44 lb up at 28-6-12, and 37 lb down and 44 lb up at 30-6-12, and 37 lb down and 44 lb up at 32-6-12 on bottomchord.The design/selection of suchconnection device(s)is the responsibility of others. LOADCASE(S)Standard 1) Dead +Snow(balanced): LumberIncrease=1.15,PlateIncrease=1.15 Uniform Loads(plf) Vert: 1-4=-51, 4-11=-61, 12-21=-20 Concentrated Loads(lb) Vert: 4=-109(F) 8=-35(F) 20=-51(F) 6=-35(F) 18=-22(F) 16=-22(F) 26=-35(F) 27=-35(F) 28=-35(F) 29=-35(F) 30=-35(F) 32=-35(F) 34=-35(F) 35=-35(F) 36=-35(F) 37=-35(F) 38=-35(F) 39=-35(F) 40=-22(F) 41=-22(F) 42=-22(F) 43=-22(F) 44=-22(F) 45=-22(F) 46=-22(F) 47=-22(F) 48=-22(F) 49=-22(F) 50=-22(F) 51=-22(F) DE Job # 59223-W1 Dansco Engineering, LLC Date: 6/13/18 WARNING – VERIFY DESIGN PARAMETERS AND READ NOTES BEFORE FABRICATION AND INSTALLATION!!! This truss design is adequate for the design parameters shown. Review and approval of design parameters is the responsibility of the building designer, not the truss designer or truss engineer. Permanent bracing requirements against out-of-plane buckling are noted/shown for individual truss members (and for the truss as a whole) subjected to gravity and wind loads. Additional permanent bracing design shall be the responsibility of the design professional of record. Temporary and erection bracing shall be the responsibility of the contractor. Reference ANSI/TPI-1, “National Design Standard for Metal Plate Connected Wood Truss Construction” and TPI/WTCA BCSI-06, “Building Component Safety Information Guide to Good Practice for Handling, Installing, Restraining and Bracing of Metal Plate Connected Wood Trusses” for additional information. Job 1802242-12T Truss T36 TrussType HalfHip Qty 1 Ply 1 1802242-12TDWHWoodside-West Clay- 4 Job Reference (optional)Run:8.200 s Apr72018 Print:8.200 s Apr72018MiTekIndustries,Inc.Tue Jun1221:12:492018 Page1ID:bRTO9oDnRLEHvJjVgeMKW3yF_s1-k8Ui1awm?r7bMzeygWkHBg_4rpViBKGop0JthZz6wFi Scale=1:61.4 0 -1 -10 T1 T2 W3 B1 W1 W2 W3 W2 W3 W2 W3 W2 W3 W2 HW1 T3 B1B2 1 2 3 4 5 6 7 8 9 10 17 16 15 14 13 12 11 22 23 24 25 26 27 28 6x8 4x6 4x8 3x8 5x12 4x4 2x4 8x8 3x4 2x4 3x8 3x4 3x8 3x8 4x10 5x6 6-6-0 6-6-0 11-11-1 5-5-1 17-5-14 5-6-13 23-0-10 5-6-13 28-7-7 5-6-13 34-4-0 5-8-9 -1-2-12 1-2-12 6-6-0 6-6-0 11-11-1 5-5-1 17-5-14 5-6-13 23-0-10 5-6-13 28-7-7 5-6-13 34-4-0 5-8-9 1 -0 -9 3 -7 -7 3 -9 -1 3 -7 -7 5.0012 PlateOffsets(X,Y)-- [2:0-6-10,Edge], [9:0-3-8,0-1-8], [12:0-3-8,0-2-0], [13:0-3-8,0-1-8], [16:0-2-12,0-4-8] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 10.0 SPACING- PlateGrip DOL Lumber DOL RepStressIncr Code 2-0-0 1.15 1.15 YES IBC2012/TPI2007 CSI. TC BC WB Matrix-MSH 0.54 0.46 1.00 DEFL. Vert(LL) Vert(TL) Horz(TL) in 0.29 -0.56 0.08 (loc) 15 15 11 l/defl >999 >727 n/a L/d 240 180 n/a PLATES MT20 Weight: 200 lb FT= 20% GRIP 197/144 LUMBER- TOP CHORD2x6SPF No.2BOT CHORD2x6SP 2400F 2.0E WEBS 2x4SPFStud*Except* W2: 2x4SPF No.2SLIDERLeft 2x4SPFStud 1-6-0 BRACING- TOP CHORD Structuralwoodsheathing directly applied or 3-3-2 oc purlins,except end verticals. BOT CHORD Rigidceiling directly applied or 7-0-12 oc bracing. MiTekrecommends that Stabilizers and requiredcross bracing beinstalled during truss erection,in accordancewithStabilizerInstallation guide. REACTIONS.(lb/size)11=1374/0-6-0(min. 0-1-8), 2=1386/0-4-0(min. 0-1-8) Max Horz2=125(LC 16)Max Uplift11=-616(LC 12), 2=-586(LC 12) MaxGrav11=1710(LC 35), 2=1469(LC 35) FORCES.(lb)-Max. Comp./Max.Ten.-All forces 250 (lb) orless exceptwhenshown. TOP CHORD 2-3=-1212/674, 3-22=-2750/1546, 22-23=-2742/1548, 4-23=-2737/1567, 4-24=-4136/2203, 24-25=-4136/2203, 5-25=-4138/2203, 5-6=-4503/2365, 6-26=-4503/2365,7-26=-4503/2365, 7-27=-4503/2365, 8-27=-4503/2365, 8-9=-4016/2080, 9-28=-2563/1308, 10-28=-2563/1308, 10-11=-1643/808 BOT CHORD 2-17=-1475/2491, 16-17=-1472/2495, 15-16=-2196/4116, 14-15=-2080/4016, 13-14=-2080/4016, 12-13=-1308/2563 WEBS 4-16=-880/1900, 5-16=-782/268, 5-15=-194/445, 6-15=-416/156, 8-15=-327/560, 8-13=-703/290, 9-13=-888/1670, 9-12=-1336/581, 10-12=-1485/2909 NOTES- 1) Unbalancedroofliveloads have been considered for this design. 2)Wind:ASCE 7-10;Vult=115mph(3-second gust)Vasd=91mph;TCDL=6.0psf;BCDL=6.0psf; h=25ft; Cat. II;Exp C; enclosed; MWFRS(envelope) gable end zone and C-CExterior(2)-1-2-12 to 1-9-4,Interior(1) 1-9-4 to 6-6-0,Exterior(2) 6-6-0 to 10-8-15zone; cantileverleft exposed ; end verticalleft exposed; porchleft and right exposed;C-C formembers and forces&MWFRS forreactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3)TCLL:ASCE 7-10;Pr=20.0 psf(roofliveload: Lumber DOL=1.15Plate DOL=1.15);Pg=20.0 psf(groundsnow);Pf=20.4 psf(flat roofsnow: Lumber DOL=1.15Plate DOL=1.15); CategoryII;Exp C; PartiallyExp.; Ct=1.1, Lu=50-0-0;Min. flatroofsnowload governs. Rainsurcharge applied to all exposedsurfaceswithslopesless than 0.500/12 in accordancewithIBC 1608.3.4.4) Unbalancedsnowloads have been considered for this design. 5)This truss has been designed for greater of minroofliveload of 12.0 psf or 2.00 times flatroofload of 15.4 psf on overhangs non-concurrentwith otherliveloads.6)Provide adequate drainage to preventwater ponding. 7)This truss has been designed for a 10.0 psf bottomchordliveload nonconcurrentwith any otherliveloads. 8)Providemechanicalconnection(by others) of truss to bearing platecapable of withstanding 100 lb uplift at joint(s) except(jt=lb)11=616, 2=586. 9)This trussis designedin accordancewith the 2012 InternationalBuilding Code section 2306.1 and referencedstandardANSI/TPI 1. LOADCASE(S)Standard DE Job # 59223-W1 Dansco Engineering, LLC Date: 6/13/18 WARNING – VERIFY DESIGN PARAMETERS AND READ NOTES BEFORE FABRICATION AND INSTALLATION!!! This truss design is adequate for the design parameters shown. Review and approval of design parameters is the responsibility of the building designer, not the truss designer or truss engineer. Permanent bracing requirements against out-of-plane buckling are noted/shown for individual truss members (and for the truss as a whole) subjected to gravity and wind loads. Additional permanent bracing design shall be the responsibility of the design professional of record. Temporary and erection bracing shall be the responsibility of the contractor. Reference ANSI/TPI-1, “National Design Standard for Metal Plate Connected Wood Truss Construction” and TPI/WTCA BCSI-06, “Building Component Safety Information Guide to Good Practice for Handling, Installing, Restraining and Bracing of Metal Plate Connected Wood Trusses” for additional information. Job 1802242-12T Truss T37 TrussType HalfHip Qty 1 Ply 1 1802242-12TDWHWoodside-West Clay- 4 Job Reference (optional)Run:8.200 s Apr72018 Print:8.200 s Apr72018MiTekIndustries,Inc.Tue Jun1221:12:502018 Page1ID:bRTO9oDnRLEHvJjVgeMKW3yF_s1-CK25EwwOm8FSz7D8EDFWjuX8hDlPwp5y2g3QD0z6wFh Scale=1:61.4 0 -1 -10 T1 T2 W7 B1 W3 W4 W5 W6 W7 W6 W7 W6 W7 W6 W1 W2 T3 B1B2 1 2 3 4 5 6 7 8 9 18 17 16 15 14 13 12 11 10 19 20 21 22 6x6 3x6 4x8 4x64x64x6 3x4 6x6 3x4 4x4 3x4 1.5x4 4x10 3x8 6x6 4x6 3x5 4-4-12 4-4-12 8-6-0 4-1-4 14-9-12 6-3-12 21-3-4 6-5-8 27-8-12 6-5-8 34-4-0 6-7-4 -1-2-12 1-2-12 4-4-12 4-4-12 8-6-0 4-1-4 14-9-12 6-3-12 21-3-4 6-5-8 27-8-12 6-5-8 34-4-0 6-7-4 1 -0 -9 4 -5 -7 4 -7 -1 4 -5 -7 5.0012 PlateOffsets(X,Y)-- [8:0-3-8,0-1-8], [10:Edge,0-3-8] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 10.0 SPACING- PlateGrip DOL Lumber DOL RepStressIncr Code 2-0-0 1.15 1.15 YES IBC2012/TPI2007 CSI. TC BC WB Matrix-MSH 0.98 0.87 0.84 DEFL. Vert(LL) Vert(TL) Horz(TL) in 0.29 -0.57 0.12 (loc) 13-14 13-14 10 l/defl >999 >721 n/a L/d 240 180 n/a PLATES MT20 Weight: 149 lb FT= 20% GRIP 197/144 LUMBER- TOP CHORD2x4SPF No.2BOT CHORD2x4SPF No.2 WEBS 2x4SPFStud*Except* W6: 2x4SPF No.2 BRACING- TOP CHORD Structuralwoodsheathing directly applied, except end verticals.BOT CHORD Rigidceiling directly applied or 4-3-14 oc bracing. WEBS 1 Row at midpt 9-11 MiTekrecommends that Stabilizers and requiredcross bracing beinstalled during truss erection,in accordancewithStabilizerInstallation guide. REACTIONS.(lb/size)10=1364/0-6-0(min. 0-2-11), 18=1373/0-4-0(min. 0-2-4) Max Horz18=147(LC 16)Max Uplift10=-611(LC 12), 18=-569(LC 12) MaxGrav10=1717(LC 35), 18=1446(LC 2) FORCES.(lb)-Max. Comp./Max.Ten.-All forces 250 (lb) orless exceptwhenshown. TOP CHORD 2-19=-2279/1377, 3-19=-2244/1394, 3-4=-2525/1472, 4-20=-3383/1818, 20-21=-3384/1817, 5-21=-3386/1817, 5-6=-3313/1719, 6-7=-3313/1719, 7-8=-3313/1719,8-22=-2238/1141, 9-22=-2238/1141, 9-10=-1656/805, 2-18=-1388/873 BOT CHORD 17-18=-259/171, 16-17=-1376/2072, 15-16=-1390/2339, 14-15=-1390/2339, 13-14=-1816/3383, 12-13=-1141/2238, 11-12=-1141/2238 WEBS 3-17=-313/125, 3-16=-131/317, 4-14=-539/1256, 5-14=-567/181, 7-13=-522/179, 8-13=-688/1279, 8-11=-1285/540, 9-11=-1335/2621, 2-17=-1137/1944 NOTES- 1) Unbalancedroofliveloads have been considered for this design. 2)Wind:ASCE 7-10;Vult=115mph(3-second gust)Vasd=91mph;TCDL=6.0psf;BCDL=6.0psf; h=25ft; Cat. II;Exp C; enclosed; MWFRS(envelope) gable end zone and C-CExterior(2)-1-2-12 to 1-9-4,Interior(1) 1-9-4 to 8-6-0,Exterior(2) 8-6-0 to 12-8-15zone; cantileverleft exposed ; end verticalleft exposed; porchleft and right exposed;C-C formembers and forces&MWFRS forreactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3)TCLL:ASCE 7-10;Pr=20.0 psf(roofliveload: Lumber DOL=1.15Plate DOL=1.15);Pg=20.0 psf(groundsnow);Pf=20.4 psf(flat roofsnow: Lumber DOL=1.15Plate DOL=1.15); CategoryII;Exp C; PartiallyExp.; Ct=1.1, Lu=50-0-0;Min. flatroofsnowload governs. Rainsurcharge applied to all exposedsurfaceswithslopesless than 0.500/12 in accordancewithIBC 1608.3.4. 4) Unbalancedsnowloads have been considered for this design.5)This truss has been designed for greater of minroofliveload of 12.0 psf or 2.00 times flatroofload of 15.4 psf on overhangs non-concurrentwith otherliveloads. 6)Provide adequate drainage to preventwater ponding.7)This truss has been designed for a 10.0 psf bottomchordliveload nonconcurrentwith any otherliveloads. 8)Providemechanicalconnection(by others) of truss to bearing platecapable of withstanding 100 lb uplift at joint(s) except(jt=lb) 10=611, 18=569.9)This trussis designedin accordancewith the 2012 InternationalBuilding Code section 2306.1 and referencedstandardANSI/TPI 1. LOADCASE(S)Standard DE Job # 59223-W1 Dansco Engineering, LLC Date: 6/13/18 WARNING – VERIFY DESIGN PARAMETERS AND READ NOTES BEFORE FABRICATION AND INSTALLATION!!! This truss design is adequate for the design parameters shown. Review and approval of design parameters is the responsibility of the building designer, not the truss designer or truss engineer. Permanent bracing requirements against out-of-plane buckling are noted/shown for individual truss members (and for the truss as a whole) subjected to gravity and wind loads. Additional permanent bracing design shall be the responsibility of the design professional of record. Temporary and erection bracing shall be the responsibility of the contractor. Reference ANSI/TPI-1, “National Design Standard for Metal Plate Connected Wood Truss Construction” and TPI/WTCA BCSI-06, “Building Component Safety Information Guide to Good Practice for Handling, Installing, Restraining and Bracing of Metal Plate Connected Wood Trusses” for additional information. Job 1802242-12T Truss T38 TrussType HalfHip Qty 1 Ply 1 1802242-12TDWHWoodside-West Clay- 4 Job Reference (optional)Run:8.200 s Apr72018 Print:8.200 s Apr72018MiTekIndustries,Inc.Tue Jun1221:12:512018 Page1ID:bRTO9oDnRLEHvJjVgeMKW3yF_s1-gWbTSFx0XSOJbHoKoxmlG53JNc6OfHu5HKo_lSz6wFg Scale=1:61.4 0 -1 -10 T1 T2 W7 B1 W3 W4 W5 W6 W7 W6 W7 W6 W1 W2 T3 B1B2 1 2 3 4 5 6 7 8 16 15 14 13 12 11 10 9 17 18 19 20 21 22 6x6 3x4 4x8 4x64x63x5 3x4 6x6 3x4 3x4 3x4 1.5x4 5x12 5x6 4x6 5-4-12 5-4-12 10-6-0 5-1-4 18-3-9 7-9-9 26-2-15 7-11-5 34-4-0 8-1-1 -1-2-12 1-2-12 5-4-12 5-4-12 10-6-0 5-1-4 18-3-9 7-9-9 26-2-15 7-11-5 34-4-0 8-1-1 1 -0 -9 5 -3 -7 5 -5 -1 5 -3 -7 5.0012 PlateOffsets(X,Y)-- [2:0-2-12,0-2-8], [9:Edge,0-3-8] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 10.0 SPACING- PlateGrip DOL Lumber DOL RepStressIncr Code 2-0-0 1.15 1.15 YES IBC2012/TPI2007 CSI. TC BC WB Matrix-MSH 0.99 0.83 0.80 DEFL. Vert(LL) Vert(TL) Horz(TL) in 0.27 -0.48 0.10 (loc) 12-14 12-14 9 l/defl >999 >855 n/a L/d 240 180 n/a PLATES MT20 Weight: 149 lb FT= 20% GRIP 197/144 LUMBER- TOP CHORD2x4SPF 1650F 1.5E*Except*T1: 2x4SPF No.2 BOT CHORD2x4SPF No.2 WEBS 2x4SPFStud*Except*W6: 2x4SPF No.2 BRACING- TOP CHORD Structuralwoodsheathing directly applied, except end verticals.BOT CHORD Rigidceiling directly applied or 4-7-2 oc bracing. WEBS 1 Row at midpt 8-9, 5-10, 8-10 MiTekrecommends that Stabilizers and requiredcross bracing beinstalled during truss erection,in accordancewithStabilizerInstallation guide. REACTIONS.(lb/size)9=1358/0-6-0(min. 0-2-10), 16=1359/0-4-0(min. 0-2-4) Max Horz16=181(LC 16)Max Uplift9=-608(LC 12), 16=-549(LC 12) MaxGrav9=1687(LC 35), 16=1446(LC 2) FORCES.(lb)-Max. Comp./Max.Ten.-All forces 250 (lb) orless exceptwhenshown. TOP CHORD 2-17=-2277/1410, 17-18=-2225/1418, 3-18=-2211/1432, 3-19=-2349/1399, 4-19=-2304/1419, 4-20=-2846/1561, 20-21=-2846/1560, 5-21=-2848/1560,5-6=-2144/1129, 6-7=-2144/1129, 7-22=-2144/1129, 8-22=-2144/1129, 8-9=-1613/794, 2-16=-1382/853 BOT CHORD 15-16=-316/233, 14-15=-1431/2041, 13-14=-1343/2165, 12-13=-1343/2165, 11-12=-1559/2846, 10-11=-1559/2846 WEBS 3-14=-290/206, 4-14=-231/296, 4-12=-285/811, 5-12=-281/124, 5-10=-828/508, 7-10=-716/245, 8-10=-1309/2484, 2-15=-1128/1863 NOTES- 1) Unbalancedroofliveloads have been considered for this design. 2)Wind:ASCE 7-10;Vult=115mph(3-second gust)Vasd=91mph;TCDL=6.0psf;BCDL=6.0psf; h=25ft; Cat. II;Exp C; enclosed; MWFRS(envelope) gable end zone and C-CExterior(2)-1-2-12 to 1-9-4,Interior(1) 1-9-4 to 10-6-0,Exterior(2) 10-6-0 to 14-8-15 zone;cantileverleft exposed ; end verticalleft exposed; porchleft and right exposed;C-C formembers and forces&MWFRS for reactionsshown; Lumber DOL=1.60 plate grip DOL=1.60 3)TCLL:ASCE 7-10;Pr=20.0 psf(roofliveload: Lumber DOL=1.15Plate DOL=1.15);Pg=20.0 psf(groundsnow);Pf=20.4 psf(flat roofsnow: Lumber DOL=1.15Plate DOL=1.15); CategoryII;Exp C; PartiallyExp.; Ct=1.1, Lu=50-0-0;Min. flatroofsnowload governs. Rainsurcharge applied to all exposedsurfaceswithslopesless than 0.500/12 in accordancewithIBC 1608.3.4.4) Unbalancedsnowloads have been considered for this design. 5)This truss has been designed for greater of minroofliveload of 12.0 psf or 2.00 times flatroofload of 15.4 psf on overhangs non-concurrentwith otherliveloads.6)Provide adequate drainage to preventwater ponding. 7)This truss has been designed for a 10.0 psf bottomchordliveload nonconcurrentwith any otherliveloads. 8)Providemechanicalconnection(by others) of truss to bearing platecapable of withstanding 100 lb uplift at joint(s) except(jt=lb)9=608, 16=549. 9)This trussis designedin accordancewith the 2012 InternationalBuilding Code section 2306.1 and referencedstandardANSI/TPI 1. LOADCASE(S)Standard DE Job # 59223-W1 Dansco Engineering, LLC Date: 6/13/18 WARNING – VERIFY DESIGN PARAMETERS AND READ NOTES BEFORE FABRICATION AND INSTALLATION!!! This truss design is adequate for the design parameters shown. Review and approval of design parameters is the responsibility of the building designer, not the truss designer or truss engineer. Permanent bracing requirements against out-of-plane buckling are noted/shown for individual truss members (and for the truss as a whole) subjected to gravity and wind loads. Additional permanent bracing design shall be the responsibility of the design professional of record. Temporary and erection bracing shall be the responsibility of the contractor. Reference ANSI/TPI-1, “National Design Standard for Metal Plate Connected Wood Truss Construction” and TPI/WTCA BCSI-06, “Building Component Safety Information Guide to Good Practice for Handling, Installing, Restraining and Bracing of Metal Plate Connected Wood Trusses” for additional information. Job 1802242-12T Truss T39 TrussType HalfHip Qty 1 Ply 1 1802242-12TDWHWoodside-West Clay- 4 Job Reference (optional)Run:8.200 s Apr72018 Print:8.200 s Apr72018MiTekIndustries,Inc.Tue Jun1221:12:522018 Page1ID:bRTO9oDnRLEHvJjVgeMKW3yF_s1-9i9rfbyeImWADRNXMeH_pJcWq0U0OkCEV_YXIuz6wFf Scale=1:61.4 0 -1 -10 T2 T3 W7 B1 W3 W4 W5 W6 W7 W6 W7 W6 W1 W2 T4 B1B2 T1 1 2 3 4 5 6 7 8 9 16 15 14 13 12 11 10 17 18 19 20 21 22 233x8 6x6 3x4 5x6 4x64x6 3x4 6x6 5x8 3x4 3x4 1.5x4 5x12 6x6 3x6 5-11-7 5-11-7 12-6-0 6-6-9 19-7-9 7-1-9 26-10-15 7-3-5 34-4-0 7-5-1 -1-2-12 1-2-12 5-11-7 5-11-7 12-6-0 6-6-9 19-7-9 7-1-9 26-10-15 7-3-5 34-4-0 7-5-1 1 -0 -9 6 -1 -7 6 -3 -1 6 -1 -7 5.0012 PlateOffsets(X,Y)-- [2:0-2-9,0-3-0], [10:Edge,0-3-8], [14:0-3-12,0-3-0] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 10.0 SPACING- PlateGrip DOL Lumber DOL RepStressIncr Code 2-0-0 1.15 1.15 YES IBC2012/TPI2007 CSI. TC BC WB Matrix-MSH 0.88 0.67 0.80 DEFL. Vert(LL) Vert(TL) Horz(TL) in 0.23 -0.39 0.09 (loc) 13-14 13-14 10 l/defl >999 >999 n/a L/d 240 180 n/a PLATES MT20 Weight: 155 lb FT= 20% GRIP 197/144 LUMBER- TOP CHORD2x4SPF No.2 *Except*T3: 2x4SPF 1650F 1.5E BOT CHORD2x4SPF No.2 WEBS 2x4SPFStud*Except*W6: 2x4SPF No.2 BRACING- TOP CHORD Structuralwoodsheathing directly applied, except end verticals.BOT CHORD Rigidceiling directly applied or 4-9-12 oc bracing. WEBS 1 Row at midpt 9-10, 5-13, 6-11, 9-11 MiTekrecommends that Stabilizers and requiredcross bracing beinstalled during truss erection,in accordancewithStabilizerInstallation guide. REACTIONS.(lb/size)10=1351/0-6-0(min. 0-2-9), 16=1345/0-4-0(min. 0-2-5) Max Horz16=215(LC 16)Max Uplift10=-605(LC 12), 16=-530(LC 12) MaxGrav10=1650(LC 35), 16=1484(LC 36) FORCES.(lb)-Max. Comp./Max.Ten.-All forces 250 (lb) orless exceptwhenshown. TOP CHORD 2-18=-2321/1411, 18-19=-2252/1421, 3-19=-2200/1435, 3-20=-2143/1322, 4-20=-2117/1326, 4-5=-2078/1341, 5-21=-2310/1320, 21-22=-2311/1320,6-22=-2313/1320, 6-7=-1673/912, 7-8=-1673/912, 8-23=-1673/912, 9-23=-1673/912, 9-10=-1583/808, 2-16=-1419/840 BOT CHORD 15-16=-353/289, 14-15=-1457/2079, 13-14=-1258/1944, 12-13=-1319/2310, 11-12=-1319/2310 WEBS 3-14=-475/199, 5-14=-282/371, 5-13=-155/475, 6-11=-816/522, 8-11=-656/225, 9-11=-1150/2108, 2-15=-1115/1853 NOTES- 1) Unbalancedroofliveloads have been considered for this design. 2)Wind:ASCE 7-10;Vult=115mph(3-second gust)Vasd=91mph;TCDL=6.0psf;BCDL=6.0psf; h=25ft; Cat. II;Exp C; enclosed; MWFRS(envelope) gable end zone and C-CExterior(2)-1-2-12 to 1-9-4,Interior(1) 1-9-4 to 12-6-0,Exterior(2) 12-6-0 to 16-8-15 zone;cantileverleft exposed ; end verticalleft exposed; porchleft and right exposed;C-C formembers and forces&MWFRS for reactionsshown; Lumber DOL=1.60 plate grip DOL=1.60 3)TCLL:ASCE 7-10;Pr=20.0 psf(roofliveload: Lumber DOL=1.15Plate DOL=1.15);Pg=20.0 psf(groundsnow);Pf=20.4 psf(flat roofsnow: Lumber DOL=1.15Plate DOL=1.15); CategoryII;Exp C; PartiallyExp.; Ct=1.1, Lu=50-0-0;Min. flatroofsnowload governs. Rainsurcharge applied to all exposedsurfaceswithslopesless than 0.500/12 in accordancewithIBC 1608.3.4.4) Unbalancedsnowloads have been considered for this design. 5)This truss has been designed for greater of minroofliveload of 12.0 psf or 2.00 times flatroofload of 15.4 psf on overhangs non-concurrentwith otherliveloads.6)Provide adequate drainage to preventwater ponding. 7)This truss has been designed for a 10.0 psf bottomchordliveload nonconcurrentwith any otherliveloads. 8)Providemechanicalconnection(by others) of truss to bearing platecapable of withstanding 100 lb uplift at joint(s) except(jt=lb)10=605, 16=530. 9)This trussis designedin accordancewith the 2012 InternationalBuilding Code section 2306.1 and referencedstandardANSI/TPI 1. LOADCASE(S)Standard DE Job # 59223-W1 Dansco Engineering, LLC Date: 6/13/18 WARNING – VERIFY DESIGN PARAMETERS AND READ NOTES BEFORE FABRICATION AND INSTALLATION!!! This truss design is adequate for the design parameters shown. Review and approval of design parameters is the responsibility of the building designer, not the truss designer or truss engineer. Permanent bracing requirements against out-of-plane buckling are noted/shown for individual truss members (and for the truss as a whole) subjected to gravity and wind loads. Additional permanent bracing design shall be the responsibility of the design professional of record. Temporary and erection bracing shall be the responsibility of the contractor. Reference ANSI/TPI-1, “National Design Standard for Metal Plate Connected Wood Truss Construction” and TPI/WTCA BCSI-06, “Building Component Safety Information Guide to Good Practice for Handling, Installing, Restraining and Bracing of Metal Plate Connected Wood Trusses” for additional information. Job 1802242-12T Truss T40 TrussType HALFHIP Qty 1 Ply 1 1802242-12TDWHWoodside-West Clay- 4 Job Reference (optional)Run:8.200 s Apr72018 Print:8.200 s Apr72018MiTekIndustries,Inc.Tue Jun1221:12:532018 Page1ID:bRTO9oDnRLEHvJjVgeMKW3yF_s1-dvjDsxzG33e0qbyjvMpDLW9g1Qry7BSOkeH4qLz6wFe Scale=1:61.6 0 -1 -10 T2 T3 W7 B1 W3 W4 W5 W6 W7 W6 W7 W6 W1 W2 T1 T4 B1B2 1 2 3 4 5 6 7 8 16 15 14 13 12 11 10 9 17 18 19 20 21 22 3x5 6x6 3x4 5x6 3x612x123x5 3x4 6x6 3x4 3x4 3x4 1.5x4 6x83x4 7-4-12 7-4-12 14-6-0 7-1-4 20-11-9 6-5-9 27-6-15 6-7-5 34-4-0 6-9-1 7-4-12 7-4-12 14-6-0 7-1-4 20-11-9 6-5-9 27-6-15 6-7-5 34-4-0 6-9-1 1 -0 -9 6 -11 -7 7 -1 -1 6 -11 -7 5.0012 PlateOffsets(X,Y)-- [16:0-1-12,0-0-0], [16:Edge,0-9-11] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 10.0 SPACING- PlateGrip DOL Lumber DOL RepStressIncr Code 2-0-0 1.15 1.15 YES IBC2012/TPI2007 CSI. TC BC WB Matrix-MSH 0.91 0.63 0.80 DEFL. Vert(LL) Vert(TL) Horz(TL) in 0.18 -0.31 0.08 (loc) 13-15 13-15 9 l/defl >999 >999 n/a L/d 240 180 n/a PLATES MT20 Weight: 161 lb FT= 20% GRIP 197/144 LUMBER- TOP CHORD2x4SPF No.2BOT CHORD2x4SPF No.2 WEBS 2x4SPFStud*Except* W4,W6: 2x4SPF No.2 BRACING- TOP CHORD Structuralwoodsheathing directly applied, except end verticals.BOT CHORD Rigidceiling directly applied or 4-9-9 oc bracing. WEBS 1 Row at midpt 8-9, 4-12, 5-10, 8-10, 1-15 MiTekrecommends that Stabilizers and requiredcross bracing beinstalled during truss erection,in accordancewithStabilizerInstallation guide. REACTIONS.(lb/size)9=1345/0-6-0(min. 0-2-8), 16=1262/0-4-0(min. 0-2-3) Max Horz16=229(LC 16)Max Uplift9=-601(LC 12), 16=-469(LC 12) MaxGrav9=1608(LC 34), 16=1414(LC 35) FORCES.(lb)-Max. Comp./Max.Ten.-All forces 250 (lb) orless exceptwhenshown. TOP CHORD 1-17=-2443/1408, 17-18=-2364/1415, 2-18=-2355/1435, 2-3=-1946/1199, 3-19=-1881/1208, 4-19=-1870/1227, 4-20=-1882/1124, 20-21=-1884/1123,5-21=-1885/1123, 5-6=-1317/745, 6-7=-1317/745, 7-22=-1317/745, 8-22=-1317/745, 8-9=-1547/823, 1-16=-1339/748 BOT CHORD 15-16=-398/331, 14-15=-1474/2174, 13-14=-1474/2174, 12-13=-1170/1730, 11-12=-1122/1882, 10-11=-1122/1882 WEBS 2-13=-702/338, 4-13=-342/478, 4-12=-259/241, 5-12=-219/314, 5-10=-803/535, 7-10=-599/206, 8-10=-1045/1844, 1-15=-1087/1854 NOTES- 1) Unbalancedroofliveloads have been considered for this design. 2)Wind:ASCE 7-10;Vult=115mph(3-second gust)Vasd=91mph;TCDL=6.0psf;BCDL=6.0psf; h=25ft; Cat. II;Exp C; enclosed; MWFRS(envelope) gable end zone and C-CExterior(2) 0-1-12 to 3-1-12,Interior(1) 3-1-12 to 14-6-0,Exterior(2) 14-6-0 to 18-8-15 zone;cantileverleft exposed ; end verticalleft exposed; porchleft and right exposed;C-C formembers and forces&MWFRS for reactionsshown; Lumber DOL=1.60 plate grip DOL=1.60 3)TCLL:ASCE 7-10;Pr=20.0 psf(roofliveload: Lumber DOL=1.15Plate DOL=1.15);Pg=20.0 psf(groundsnow);Pf=20.4 psf(flat roofsnow: Lumber DOL=1.15Plate DOL=1.15); CategoryII;Exp C; PartiallyExp.; Ct=1.1, Lu=50-0-0;Min. flatroofsnowload governs. Rainsurcharge applied to all exposedsurfaceswithslopesless than 0.500/12 in accordancewithIBC 1608.3.4.4) Unbalancedsnowloads have been considered for this design. 5)Provide adequate drainage to preventwater ponding. 6)This truss has been designed for a 10.0 psf bottomchordliveload nonconcurrentwith any otherliveloads.7)Providemechanicalconnection(by others) of truss to bearing platecapable of withstanding 100 lb uplift at joint(s) except(jt=lb) 9=601, 16=469. 8)This trussis designedin accordancewith the 2012 InternationalBuilding Code section 2306.1 and referencedstandardANSI/TPI 1. LOADCASE(S)Standard DE Job # 59223-W1 Dansco Engineering, LLC Date: 6/13/18 WARNING – VERIFY DESIGN PARAMETERS AND READ NOTES BEFORE FABRICATION AND INSTALLATION!!! This truss design is adequate for the design parameters shown. Review and approval of design parameters is the responsibility of the building designer, not the truss designer or truss engineer. Permanent bracing requirements against out-of-plane buckling are noted/shown for individual truss members (and for the truss as a whole) subjected to gravity and wind loads. Additional permanent bracing design shall be the responsibility of the design professional of record. Temporary and erection bracing shall be the responsibility of the contractor. Reference ANSI/TPI-1, “National Design Standard for Metal Plate Connected Wood Truss Construction” and TPI/WTCA BCSI-06, “Building Component Safety Information Guide to Good Practice for Handling, Installing, Restraining and Bracing of Metal Plate Connected Wood Trusses” for additional information. Job 1802242-12T Truss T41 TrussType Jack-ClosedGirder Qty 1 Ply 1 1802242-12TDWHWoodside-West Clay- 4 Job Reference (optional)Run:8.200 s Apr72018 Print:8.200 s Apr72018MiTekIndustries,Inc.Tue Jun1221:12:552018 Page1ID:bRTO9oDnRLEHvJjVgeMKW3yF_s1-ZHr_Hd_Xbhuk4u561mrhQxE6QEXTb49hBymBuDz6wFc Scale=1:34.8 0 -1 -10 W1 T1 T3 W5 B1 W2 W3 W4 W5 W6 W5 W4 B2 T2 1 2 3 4 5 6 7 13 12 11 10 9 8 14 15 16 17 18 19 20 21 22 23 24 25 26 3x4 4x6 3x4 3x43x55x63x8 6x6 1.5x4 3x4 5x6 3x8 4-9-0 4-9-0 9-4-13 4-7-13 14-0-11 4-7-13 19-0-0 4-11-5 -1-2-12 1-2-12 4-9-0 4-9-0 9-4-13 4-7-13 14-0-11 4-7-13 19-0-0 4-11-5 1 -0 -9 3 -0 -5 2 -10 -11 5.0012 LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 10.0 SPACING- PlateGrip DOL Lumber DOL RepStressIncr Code 2-0-0 1.15 1.15 NO IBC2012/TPI2007 CSI. TC BC WB Matrix-MSH 0.54 0.56 0.85 DEFL. Vert(LL) Vert(TL) Horz(TL) in 0.09 -0.21 0.03 (loc) 10 10-12 8 l/defl >999 >999 n/a L/d 240 180 n/a PLATES MT20 Weight: 79 lb FT= 20% GRIP 197/144 LUMBER- TOP CHORD2x4SPF No.2 BOT CHORD2x4SPF No.2WEBS2x4SPFStud BRACING- TOP CHORD Structuralwoodsheathing directly applied or 3-4-0 oc purlins, except end verticals.BOT CHORD Rigidceiling directly applied or 8-5-5 oc bracing. MiTekrecommends that Stabilizers and requiredcross bracing beinstalled during truss erection,in accordancewithStabilizer Installation guide.REACTIONS.(lb/size)13=1139/0-6-0(min. 0-1-15), 8=1191/0-6-0(min. 0-2-0) Max Horz13=120(LC 9) Max Uplift13=-292(LC 8), 8=-334(LC 9)MaxGrav13=1226(LC 32), 8=1281(LC 31) FORCES.(lb)-Max. Comp./Max.Ten.-All forces 250 (lb) orless exceptwhenshown.TOP CHORD 2-13=-1179/311, 2-3=-1841/448, 3-15=-2296/608, 15-16=-2297/609, 4-16=-2300/609, 4-17=-2296/607, 17-18=-2296/607, 5-18=-2296/607, 5-6=-1783/477, 6-19=-1783/477, 19-20=-1783/477, 7-20=-1783/477, 7-8=-1182/380BOT CHORD 11-12=-473/1659, 11-21=-473/1659, 10-21=-473/1659, 10-22=-483/1783, 22-23=-483/1783, 9-23=-483/1783 WEBS 2-12=-352/1543, 3-10=-193/759, 4-10=-500/258, 5-10=-165/592, 5-9=-772/347, 7-9=-510/1970 NOTES- 1) Unbalancedroofliveloads have been considered for this design. 2)Wind:ASCE 7-10;Vult=115mph(3-second gust)Vasd=91mph;TCDL=6.0psf;BCDL=6.0psf; h=25ft; Cat. II;Exp C; enclosed; MWFRS(envelope) gable end zone;cantileverleft and right exposed ; end verticalleft and right exposed; Lumber DOL=1.60 plate grip DOL=1.60 3)TCLL:ASCE 7-10;Pr=20.0 psf(roofliveload: Lumber DOL=1.15Plate DOL=1.15);Pg=20.0 psf(groundsnow);Pf=20.4 psf(flat roofsnow: Lumber DOL=1.15Plate DOL=1.15); CategoryII;Exp C; PartiallyExp.; Ct=1.1, Lu=50-0-0;Min. flatroofsnowload governs. Rainsurcharge applied to all exposedsurfaceswithslopesless than 0.500/12 in accordancewithIBC 1608.3.4.4) Unbalancedsnowloads have been considered for this design. 5)This truss has been designed for greater of minroofliveload of 12.0 psf or 2.00 times flatroofload of 15.4 psf on overhangs non-concurrentwith otherliveloads.6)Provide adequate drainage to preventwater ponding. 7)This truss has been designed for a 10.0 psf bottomchordliveload nonconcurrentwith any otherliveloads. 8)Providemechanicalconnection(by others) of truss to bearing platecapable of withstanding 100 lb uplift at joint(s) except(jt=lb)13=292, 8=334. 9)This trussis designedin accordancewith the 2012 InternationalBuilding Code section 2306.1 and referencedstandardANSI/TPI 1. 10) Hanger(s) or otherconnection device(s)shall be providedsufficient to supportconcentratedload(s) 214 lb down and 202 lb up at 4-9-0, 80 lb down and 84 lb up at 6-9-12, 80 lb down and 84 lb up at 8-9-12, 80 lb down and 84 lb up at 10-9-12, 80 lb down and 84lb up at 12-9-12, 80 lb down and 84 lb up at 14-9-12, and 80 lb down and 84 lb up at 16-9-12, and 88 lb down and 81 lb up at 18-5-4 on top chord, and 115 lb down at 4-9-0, 45 lb down at 6-9-12, 45 lb down at 8-9-12, 45 lb down at 10-9-12, 45 lb down at 12-9-12, 45 lb down at 14-9-12, and 45 lb down at 16-9-12, and 57 lb down at 18-5-4 on bottomchord.The design/selection of suchconnection device(s)is the responsibility of others.Continued on page 2 DE Job # 59223-W1 Dansco Engineering, LLC Date: 6/13/18 WARNING – VERIFY DESIGN PARAMETERS AND READ NOTES BEFORE FABRICATION AND INSTALLATION!!! This truss design is adequate for the design parameters shown. Review and approval of design parameters is the responsibility of the building designer, not the truss designer or truss engineer. Permanent bracing requirements against out-of-plane buckling are noted/shown for individual truss members (and for the truss as a whole) subjected to gravity and wind loads. Additional permanent bracing design shall be the responsibility of the design professional of record. Temporary and erection bracing shall be the responsibility of the contractor. Reference ANSI/TPI-1, “National Design Standard for Metal Plate Connected Wood Truss Construction” and TPI/WTCA BCSI-06, “Building Component Safety Information Guide to Good Practice for Handling, Installing, Restraining and Bracing of Metal Plate Connected Wood Trusses” for additional information. Job 1802242-12T Truss T41 TrussType Jack-ClosedGirder Qty 1 Ply 1 1802242-12TDWHWoodside-West Clay- 4 Job Reference (optional)Run:8.200 s Apr72018 Print:8.200 s Apr72018MiTekIndustries,Inc.Tue Jun1221:12:552018 Page2ID:bRTO9oDnRLEHvJjVgeMKW3yF_s1-ZHr_Hd_Xbhuk4u561mrhQxE6QEXTb49hBymBuDz6wFc NOTES- 11)In the LOAD CASE(S)section,loads applied to the face of the truss are noted as front(F) or back(B). LOADCASE(S)Standard1) Dead +Snow(balanced): LumberIncrease=1.15,PlateIncrease=1.15 Uniform Loads(plf) Vert: 1-2=-51, 2-3=-51, 3-7=-61, 8-13=-20 Concentrated Loads(lb) Vert: 6=-48(B) 11=-29(B) 12=-74(B) 3=-157(B) 15=-48(B) 16=-48(B) 17=-48(B) 18=-48(B) 19=-48(B) 20=-66(B) 21=-29(B) 22=-29(B) 23=-29(B) 24=-29(B) 25=-29(B) 26=-35(B) DE Job # 59223-W1 Dansco Engineering, LLC Date: 6/13/18 WARNING – VERIFY DESIGN PARAMETERS AND READ NOTES BEFORE FABRICATION AND INSTALLATION!!! This truss design is adequate for the design parameters shown. Review and approval of design parameters is the responsibility of the building designer, not the truss designer or truss engineer. Permanent bracing requirements against out-of-plane buckling are noted/shown for individual truss members (and for the truss as a whole) subjected to gravity and wind loads. Additional permanent bracing design shall be the responsibility of the design professional of record. Temporary and erection bracing shall be the responsibility of the contractor. Reference ANSI/TPI-1, “National Design Standard for Metal Plate Connected Wood Truss Construction” and TPI/WTCA BCSI-06, “Building Component Safety Information Guide to Good Practice for Handling, Installing, Restraining and Bracing of Metal Plate Connected Wood Trusses” for additional information. Job 1802242-12T Truss T42 TrussType Jack-Closed Qty 1 Ply 1 1802242-12TDWHWoodside-West Clay- 4 Job Reference (optional)Run:8.200 s Apr72018 Print:8.200 s Apr72018MiTekIndustries,Inc.Tue Jun1221:12:562018 Page1ID:bRTO9oDnRLEHvJjVgeMKW3yF_s1-1UPMVz?9M_0bh2gIbUMwz9nCGdwaKcoqQcWlRgz6wFb Scale=1:34.5 0 -1 -10 W1 T1 T2 W5 B1 W2 W3 W4 W5 W4 B2 1 2 3 4 5 10 9 8 7 6 11 12 13 14 15 12x12 6x6 2x43x4 4x4 1.5x4 4x10 3x8 6-7-8 6-7-8 12-8-0 6-0-8 19-0-0 6-4-0 -1-2-12 1-2-12 6-7-8 6-7-8 12-8-0 6-0-8 19-0-0 6-4-0 1 -0 -9 3 -8 -1 3 -9 -11 3 -8 -1 5.0012 PlateOffsets(X,Y)-- [10:0-1-12,0-0-0], [10:Edge,0-9-11] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 10.0 SPACING- PlateGrip DOL Lumber DOL RepStressIncr Code 2-0-0 1.15 1.15 YES IBC2012/TPI2007 CSI. TC BC WB Matrix-MSH 0.85 0.38 0.57 DEFL. Vert(LL) Vert(TL) Horz(TL) in -0.05 -0.13 0.02 (loc) 7-9 6-7 6 l/defl >999 >999 n/a L/d 240 180 n/a PLATES MT20 Weight: 79 lb FT= 20% GRIP 197/144 LUMBER- TOP CHORD2x4SPF No.2BOT CHORD2x4SPF No.2 WEBS 2x4SPFStud BRACING- TOP CHORD Structuralwoodsheathing directly applied or 4-6-13 oc purlins,except end verticals. BOT CHORD Rigidceiling directly applied or 10-0-0 oc bracing. MiTekrecommends that Stabilizers and requiredcross bracing beinstalled during truss erection,in accordancewithStabilizerInstallation guide. REACTIONS.(lb/size)10=775/0-6-0(min. 0-1-8), 6=742/0-6-0(min. 0-1-8) Max Horz10=155(LC 13)Max Uplift10=-138(LC 12), 6=-155(LC 13) MaxGrav10=875(LC 36), 6=912(LC 35) FORCES.(lb)-Max. Comp./Max.Ten.-All forces 250 (lb) orless exceptwhenshown. TOP CHORD 2-10=-815/243, 2-11=-1136/158, 11-12=-1111/165, 3-12=-1098/184, 3-13=-1194/228, 13-14=-1194/228, 4-14=-1197/227, 4-15=-1194/226, 5-15=-1194/226, 5-6=-853/184BOT CHORD 9-10=-311/376, 8-9=-273/1017, 7-8=-273/1017 WEBS 2-9=-54/857, 4-7=-607/205, 5-7=-230/1317 NOTES- 1) Unbalancedroofliveloads have been considered for this design. 2)Wind:ASCE 7-10;Vult=115mph(3-second gust)Vasd=91mph;TCDL=6.0psf;BCDL=6.0psf; h=25ft; Cat. II;Exp C; enclosed; MWFRS(envelope) gable end zone and C-CExterior(2)-1-2-12 to 1-9-4,Interior(1) 1-9-4 to 6-7-8,Exterior(2) 6-7-8 to 10-10-7zone; cantileverleft and right exposed ; end verticalleft and right exposed;C-C formembers and forces&MWFRS forreactionsshown; Lumber DOL=1.60 plate grip DOL=1.60 3)TCLL:ASCE 7-10;Pr=20.0 psf(roofliveload: Lumber DOL=1.15Plate DOL=1.15);Pg=20.0 psf(groundsnow);Pf=20.4 psf(flat roofsnow: Lumber DOL=1.15Plate DOL=1.15); CategoryII;Exp C; PartiallyExp.; Ct=1.1, Lu=50-0-0;Min. flatroofsnowload governs. Rainsurcharge applied to all exposedsurfaceswithslopesless than 0.500/12 in accordancewithIBC 1608.3.4. 4) Unbalancedsnowloads have been considered for this design. 5)This truss has been designed for greater of minroofliveload of 12.0 psf or 2.00 times flatroofload of 15.4 psf on overhangs non-concurrentwith otherliveloads. 6)Provide adequate drainage to preventwater ponding.7)This truss has been designed for a 10.0 psf bottomchordliveload nonconcurrentwith any otherliveloads. 8)Providemechanicalconnection(by others) of truss to bearing platecapable of withstanding 100 lb uplift at joint(s) except(jt=lb) 10=138, 6=155.9)This trussis designedin accordancewith the 2012 InternationalBuilding Code section 2306.1 and referencedstandardANSI/TPI 1. LOADCASE(S)Standard DE Job # 59223-W1 Dansco Engineering, LLC Date: 6/13/18 WARNING – VERIFY DESIGN PARAMETERS AND READ NOTES BEFORE FABRICATION AND INSTALLATION!!! This truss design is adequate for the design parameters shown. Review and approval of design parameters is the responsibility of the building designer, not the truss designer or truss engineer. Permanent bracing requirements against out-of-plane buckling are noted/shown for individual truss members (and for the truss as a whole) subjected to gravity and wind loads. Additional permanent bracing design shall be the responsibility of the design professional of record. Temporary and erection bracing shall be the responsibility of the contractor. Reference ANSI/TPI-1, “National Design Standard for Metal Plate Connected Wood Truss Construction” and TPI/WTCA BCSI-06, “Building Component Safety Information Guide to Good Practice for Handling, Installing, Restraining and Bracing of Metal Plate Connected Wood Trusses” for additional information. Job 1802242-12T Truss T43 TrussType Jack-Closed Qty 1 Ply 1 1802242-12TDWHWoodside-West Clay- 4 Job Reference (optional)Run:8.200 s Apr72018 Print:8.200 s Apr72018MiTekIndustries,Inc.Tue Jun1221:12:572018 Page1ID:bRTO9oDnRLEHvJjVgeMKW3yF_s1-VgzkiJ0n7I8SJCFU8Bt9WMJUl1DA34x_fGFIz6z6wFa Scale=1:34.7 0 -1 -10 W1 T1 T2 W6 B1 W2 W3 W4 W5 W6 W5 B2 1 2 3 4 5 6 11 10 9 8 7 12 1314 15 3x6 3x4 6x6 1.5x43x4 4x6 3x4 1.5x4 4x8 3x5 8-7-8 8-7-8 13-8-0 5-0-8 19-0-0 5-4-0 -1-2-12 1-2-12 4-5-8 4-5-8 8-7-8 4-2-0 13-8-0 5-0-8 19-0-0 5-4-0 1 -0 -9 4 -6 -1 4 -7 -11 4 -6 -1 5.0012 LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 10.0 SPACING- PlateGrip DOL Lumber DOL RepStressIncr Code 2-0-0 1.15 1.15 YES IBC2012/TPI2007 CSI. TC BC WB Matrix-MSH 0.42 0.55 0.51 DEFL. Vert(LL) Vert(TL) Horz(TL) in -0.13 -0.33 0.02 (loc) 9-11 9-11 7 l/defl >999 >674 n/a L/d 240 180 n/a PLATES MT20 Weight: 85 lb FT= 20% GRIP 197/144 LUMBER- TOP CHORD2x4SPF No.2 BOT CHORD2x4SPF No.2WEBS2x4SPFStud BRACING- TOP CHORD Structuralwoodsheathing directly applied or 5-9-6 oc purlins, except end verticals.BOT CHORD Rigidceiling directly applied or 9-5-11 oc bracing. MiTekrecommends that Stabilizers and requiredcross bracing beinstalled during truss erection,in accordancewithStabilizer Installation guide.REACTIONS.(lb/size)11=763/0-6-0(min. 0-1-8), 7=734/0-6-0(min. 0-1-8) Max Horz11=191(LC 13) Max Uplift11=-131(LC 16), 7=-151(LC 13)MaxGrav11=941(LC 36), 7=868(LC 35) FORCES.(lb)-Max. Comp./Max.Ten.-All forces 250 (lb) orless exceptwhenshown.TOP CHORD 2-11=-366/151, 3-4=-961/178, 4-13=-798/189, 13-14=-800/189, 5-14=-801/189, 5-15=-798/188, 6-15=-798/188, 6-7=-816/189 BOT CHORD 10-11=-369/980, 9-10=-369/980, 8-9=-253/839WEBS3-11=-954/189, 4-9=0/295, 4-8=-283/65, 5-8=-510/176, 6-8=-203/1002 NOTES- 1) Unbalancedroofliveloads have been considered for this design. 2)Wind:ASCE 7-10;Vult=115mph(3-second gust)Vasd=91mph;TCDL=6.0psf;BCDL=6.0psf; h=25ft; Cat. II;Exp C; enclosed; MWFRS(envelope) gable end zone and C-CExterior(2)-1-2-12 to 1-9-4,Interior(1) 1-9-4 to 8-7-8,Exterior(2) 8-7-8 to 12-10-7zone; cantileverleft and right exposed ; end verticalleft and right exposed;C-C formembers and forces&MWFRS forreactionsshown; Lumber DOL=1.60 plate grip DOL=1.60 3)TCLL:ASCE 7-10;Pr=20.0 psf(roofliveload: Lumber DOL=1.15Plate DOL=1.15);Pg=20.0 psf(groundsnow);Pf=20.4 psf(flat roofsnow: Lumber DOL=1.15Plate DOL=1.15); CategoryII;Exp C; PartiallyExp.; Ct=1.1, Lu=50-0-0;Min. flatroofsnowload governs. Rainsurcharge applied to all exposedsurfaceswithslopesless than 0.500/12 in accordancewithIBC 1608.3.4. 4) Unbalancedsnowloads have been considered for this design. 5)This truss has been designed for greater of minroofliveload of 12.0 psf or 2.00 times flatroofload of 15.4 psf on overhangsnon-concurrentwith otherliveloads. 6)Provide adequate drainage to preventwater ponding. 7)This truss has been designed for a 10.0 psf bottomchordliveload nonconcurrentwith any otherliveloads.8)Providemechanicalconnection(by others) of truss to bearing platecapable of withstanding 100 lb uplift at joint(s) except(jt=lb) 11=131, 7=151. 9)This trussis designedin accordancewith the 2012 InternationalBuilding Code section 2306.1 and referencedstandardANSI/TPI 1. LOADCASE(S)Standard DE Job # 59223-W1 Dansco Engineering, LLC Date: 6/13/18 WARNING – VERIFY DESIGN PARAMETERS AND READ NOTES BEFORE FABRICATION AND INSTALLATION!!! This truss design is adequate for the design parameters shown. Review and approval of design parameters is the responsibility of the building designer, not the truss designer or truss engineer. Permanent bracing requirements against out-of-plane buckling are noted/shown for individual truss members (and for the truss as a whole) subjected to gravity and wind loads. Additional permanent bracing design shall be the responsibility of the design professional of record. Temporary and erection bracing shall be the responsibility of the contractor. Reference ANSI/TPI-1, “National Design Standard for Metal Plate Connected Wood Truss Construction” and TPI/WTCA BCSI-06, “Building Component Safety Information Guide to Good Practice for Handling, Installing, Restraining and Bracing of Metal Plate Connected Wood Trusses” for additional information. Job 1802242-12T Truss T44 TrussType Jack-Closed Qty 1 Ply 1 1802242-12TDWHWoodside-West Clay- 4 Job Reference (optional)Run:8.200 s Apr72018 Print:8.200 s Apr72018MiTekIndustries,Inc.Tue Jun1221:12:582018 Page1ID:bRTO9oDnRLEHvJjVgeMKW3yF_s1-zsX6wf1PubGJxMqgivOO2asf?RZdoUT7uw?rVYz6wFZ Scale=1:36.1 0 -1 -10 W1 T1 T2 W7 B1W2 W3 W4 W5 W6 W6 B2 1 2 3 4 5 6 11 10 9 8 7 12 13 14 15 16 3x4 4x6 4x4 2x4 3x53x44x4 3x4 3x8 3x4 5-4-10 5-4-10 10-7-8 5-2-14 19-0-0 8-4-8 -1-2-12 1-2-12 5-4-10 5-4-10 10-7-8 5-2-14 14-8-0 4-0-8 19-0-0 4-4-0 1 -0 -9 5 -4 -1 5 -5 -11 5 -4 -1 5.0012 LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 10.0 SPACING- PlateGrip DOL Lumber DOL RepStressIncr Code 2-0-0 1.15 1.15 YES IBC2012/TPI2007 CSI. TC BC WB Matrix-MSH 0.39 0.53 0.68 DEFL. Vert(LL) Vert(TL) Horz(TL) in -0.14 -0.37 0.02 (loc) 7-8 7-8 7 l/defl >999 >608 n/a L/d 240 180 n/a PLATES MT20 Weight: 87 lb FT= 20% GRIP 197/144 LUMBER- TOP CHORD2x4SPF No.2 BOT CHORD2x4SPF No.2WEBS2x4SPFStud BRACING- TOP CHORD Structuralwoodsheathing directly applied or 4-11-13 oc purlins, except end verticals.BOT CHORD Rigidceiling directly applied or 9-9-0 oc bracing. MiTekrecommends that Stabilizers and requiredcross bracing beinstalled during truss erection,in accordancewithStabilizer Installation guide.REACTIONS.(lb/size)11=753/0-6-0(min. 0-1-9), 7=724/0-6-0(min. 0-1-8) Max Horz11=227(LC 13) Max Uplift11=-144(LC 16), 7=-146(LC 13)MaxGrav11=996(LC 36), 7=812(LC 35) FORCES.(lb)-Max. Comp./Max.Ten.-All forces 250 (lb) orless exceptwhenshown.TOP CHORD 2-11=-936/226, 2-12=-1288/157, 3-12=-1135/174, 3-13=-863/146, 13-14=-796/154, 4-14=-770/168, 4-5=-714/176 BOT CHORD 10-11=-287/310, 9-10=-352/1113, 8-9=-352/1113, 7-8=-193/504WEBS2-10=-83/941, 3-8=-462/162, 5-8=-68/466, 5-7=-765/227 NOTES- 1) Unbalancedroofliveloads have been considered for this design. 2)Wind:ASCE 7-10;Vult=115mph(3-second gust)Vasd=91mph;TCDL=6.0psf;BCDL=6.0psf; h=25ft; Cat. II;Exp C; enclosed; MWFRS(envelope) gable end zone and C-CExterior(2)-1-2-12 to 1-9-4,Interior(1) 1-9-4 to 10-7-8,Exterior(2) 10-7-8 to 14-8-0 zone;cantileverleft and right exposed ; end verticalleft and right exposed;C-C formembers and forces&MWFRS forreactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3)TCLL:ASCE 7-10;Pr=20.0 psf(roofliveload: Lumber DOL=1.15Plate DOL=1.15);Pg=20.0 psf(groundsnow);Pf=20.4 psf(flat roofsnow: Lumber DOL=1.15Plate DOL=1.15); CategoryII;Exp C; PartiallyExp.; Ct=1.1, Lu=50-0-0;Min. flatroofsnowload governs. Rainsurcharge applied to all exposedsurfaceswithslopesless than 0.500/12 in accordancewithIBC 1608.3.4. 4) Unbalancedsnowloads have been considered for this design. 5)This truss has been designed for greater of minroofliveload of 12.0 psf or 2.00 times flatroofload of 15.4 psf on overhangsnon-concurrentwith otherliveloads. 6)Provide adequate drainage to preventwater ponding. 7)This truss has been designed for a 10.0 psf bottomchordliveload nonconcurrentwith any otherliveloads.8)Providemechanicalconnection(by others) of truss to bearing platecapable of withstanding 100 lb uplift at joint(s) except(jt=lb) 11=144, 7=146. 9)This trussis designedin accordancewith the 2012 InternationalBuilding Code section 2306.1 and referencedstandardANSI/TPI 1. LOADCASE(S)Standard DE Job # 59223-W1 Dansco Engineering, LLC Date: 6/13/18 WARNING – VERIFY DESIGN PARAMETERS AND READ NOTES BEFORE FABRICATION AND INSTALLATION!!! This truss design is adequate for the design parameters shown. Review and approval of design parameters is the responsibility of the building designer, not the truss designer or truss engineer. Permanent bracing requirements against out-of-plane buckling are noted/shown for individual truss members (and for the truss as a whole) subjected to gravity and wind loads. Additional permanent bracing design shall be the responsibility of the design professional of record. Temporary and erection bracing shall be the responsibility of the contractor. Reference ANSI/TPI-1, “National Design Standard for Metal Plate Connected Wood Truss Construction” and TPI/WTCA BCSI-06, “Building Component Safety Information Guide to Good Practice for Handling, Installing, Restraining and Bracing of Metal Plate Connected Wood Trusses” for additional information. Job 1802242-12T Truss T45 TrussType Jack-Closed Qty 1 Ply 1 1802242-12TDWHWoodside-West Clay- 4 Job Reference (optional)Run:8.200 s Apr72018 Print:8.200 s Apr72018MiTekIndustries,Inc.Tue Jun1221:12:592018 Page1ID:bRTO9oDnRLEHvJjVgeMKW3yF_s1-R34U7_11fvOAYWPtGcwdbnPmOrxVXwyG6akP2_z6wFY Scale=1:40.5 0 -1 -10 W1 T2 T3 W7 B1W2 W3 W4 W5 W6 B2 T1 1 2 3 4 5 6 11 10 9 8 7 12 13 14 15 16 17 18 3x4 4x6 3x8 6x6 3x4 3x43x44x4 3x4 3x4 5-11-7 5-11-7 12-7-8 6-8-2 19-0-0 6-4-8 -1-2-12 1-2-12 5-11-7 5-11-7 12-7-8 6-8-2 19-0-0 6-4-8 1 -0 -9 6 -2 -1 6 -3 -11 6 -2 -1 5.0012 LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 10.0 SPACING- PlateGrip DOL Lumber DOL RepStressIncr Code 2-0-0 1.15 1.15 YES IBC2012/TPI2007 CSI. TC BC WB Matrix-MSH 0.67 0.43 0.73 DEFL. Vert(LL) Vert(TL) Horz(TL) in -0.05 -0.12 0.03 (loc) 7-8 7-8 7 l/defl >999 >999 n/a L/d 240 180 n/a PLATES MT20 Weight: 87 lb FT= 20% GRIP 197/144 LUMBER- TOP CHORD2x4SPF No.2 BOT CHORD2x4SPF No.2WEBS2x4SPFStud*Except* W6: 2x4SPF No.2 BRACING- TOP CHORD Structuralwoodsheathing directly applied or 4-8-8 oc purlins, except end verticals.BOT CHORD Rigidceiling directly applied or 9-10-4 oc bracing. WEBS 1 Row at midpt 5-7 MiTekrecommends that Stabilizers and requiredcross bracing beinstalled during truss erection,in accordancewithStabilizerInstallation guide. REACTIONS.(lb/size)11=745/0-6-0(min. 0-1-9), 7=712/0-6-0(min. 0-1-8) Max Horz11=264(LC 13)Max Uplift11=-152(LC 16), 7=-140(LC 13) MaxGrav11=1005(LC 36), 7=745(LC 2) FORCES.(lb)-Max. Comp./Max.Ten.-All forces 250 (lb) orless exceptwhenshown. TOP CHORD 2-11=-946/221, 2-13=-1397/171, 3-13=-1228/190, 3-14=-771/142, 4-14=-670/145, 4-15=-650/147, 5-15=-623/161, 6-7=-258/90BOT CHORD 10-11=-331/350, 9-10=-352/1211, 8-9=-352/1211, 7-8=-217/593 WEBS 2-10=-72/992, 3-8=-677/196, 5-8=-8/444, 5-7=-808/212 NOTES- 1) Unbalancedroofliveloads have been considered for this design. 2)Wind:ASCE 7-10;Vult=115mph(3-second gust)Vasd=91mph;TCDL=6.0psf;BCDL=6.0psf; h=25ft; Cat. II;Exp C; enclosed; MWFRS(envelope) gable end zone and C-CExterior(2)-1-2-12 to 1-9-4,Interior(1) 1-9-4 to 12-7-8,Exterior(2) 12-7-8 to 16-10-7 zone;cantileverleft and right exposed ; end verticalleft and right exposed;C-C formembers and forces&MWFRS forreactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3)TCLL:ASCE 7-10;Pr=20.0 psf(roofliveload: Lumber DOL=1.15Plate DOL=1.15);Pg=20.0 psf(groundsnow);Pf=20.4 psf(flat roofsnow: Lumber DOL=1.15Plate DOL=1.15); CategoryII;Exp C; PartiallyExp.; Ct=1.1, Lu=50-0-0;Min. flatroofsnowload governs. Rainsurcharge applied to all exposedsurfaceswithslopesless than 0.500/12 in accordancewithIBC 1608.3.4. 4) Unbalancedsnowloads have been considered for this design. 5)This truss has been designed for greater of minroofliveload of 12.0 psf or 2.00 times flatroofload of 15.4 psf on overhangs non-concurrentwith otherliveloads. 6)Provide adequate drainage to preventwater ponding.7)This truss has been designed for a 10.0 psf bottomchordliveload nonconcurrentwith any otherliveloads. 8)Providemechanicalconnection(by others) of truss to bearing platecapable of withstanding 100 lb uplift at joint(s) except(jt=lb) 11=152, 7=140.9)This trussis designedin accordancewith the 2012 InternationalBuilding Code section 2306.1 and referencedstandardANSI/TPI 1. LOADCASE(S)Standard DE Job # 59223-W1 Dansco Engineering, LLC Date: 6/13/18 WARNING – VERIFY DESIGN PARAMETERS AND READ NOTES BEFORE FABRICATION AND INSTALLATION!!! This truss design is adequate for the design parameters shown. Review and approval of design parameters is the responsibility of the building designer, not the truss designer or truss engineer. Permanent bracing requirements against out-of-plane buckling are noted/shown for individual truss members (and for the truss as a whole) subjected to gravity and wind loads. Additional permanent bracing design shall be the responsibility of the design professional of record. Temporary and erection bracing shall be the responsibility of the contractor. Reference ANSI/TPI-1, “National Design Standard for Metal Plate Connected Wood Truss Construction” and TPI/WTCA BCSI-06, “Building Component Safety Information Guide to Good Practice for Handling, Installing, Restraining and Bracing of Metal Plate Connected Wood Trusses” for additional information. Job 1802242-12T Truss T46 TrussType HALFHIPGIRDER Qty 1 Ply 3 1802242-12TDWHWoodside-West Clay- 4 Job Reference (optional)Run:8.200 s Apr72018 Print:8.200 s Apr72018MiTekIndustries,Inc.Tue Jun1221:13:002018 Page1ID:bRTO9oDnRLEHvJjVgeMKW3yF_s1-wFesLK2fQDW1Ag_3qKRs7?xtvFFiGLvQLEUyaRz6wFX Scale=1:43.5 0 -1 -10 T2 T3 W7 B1 W1 W2 W3 W4 W5 W6 T1 B2HW1 1 2 3 4 5 6 10 9 8 7 14 15 16 17 18 19 20 21 22 4x6 8x8 2x4 8x88x8 4x4 3x8 10x10 6x8 10x10 4-4-8 4-4-8 9-6-0 5-1-8 14-7-8 5-1-8 19-0-0 4-4-8 4-4-8 4-4-8 9-6-0 5-1-8 14-7-8 5-1-8 19-0-0 4-4-8 1 -0 -9 7 -0 -1 7 -1 -11 7 -0 -1 5.0012 PlateOffsets(X,Y)-- [5:0-4-0,0-3-4], [8:0-3-8,0-5-12], [9:0-5-0,0-6-0] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 10.0 SPACING- PlateGrip DOL Lumber DOL RepStressIncr Code 2-0-0 1.15 1.15 NO IBC2012/TPI2007 CSI. TC BC WB Matrix-MSH 0.94 0.56 0.88 DEFL. Vert(LL) Vert(TL) Horz(TL) in -0.14 -0.34 0.05 (loc) 9-10 9-10 7 l/defl >999 >657 n/a L/d 240 180 n/a PLATES MT20 Weight: 412 lb FT= 20% GRIP 197/144 LUMBER- TOP CHORD2x6SPF No.2BOT CHORD2x8SP 2400F 2.0E WEBS 2x4SPFStud*Except* W3,W5,W6: 2x4SPF No.2WEDGE Left: 2x4SPFStud BRACING- TOP CHORD Structuralwoodsheathing directly applied or 4-8-11 oc purlins,except end verticals. BOT CHORD Rigidceiling directly applied or 10-0-0 oc bracing. REACTIONS.(lb/size)7=11032/0-6-0(min. 0-3-1), 1=8128/0-6-0(min. 0-2-5) Max Horz1=245(LC 12) Max Uplift7=-1687(LC 12), 1=-2011(LC 12)MaxGrav7=11101(LC 31), 1=8405(LC 2) FORCES.(lb)-Max. Comp./Max.Ten.-All forces 250 (lb) orless exceptwhenshown. TOP CHORD 1-14=-15379/3495, 2-14=-15342/3513, 2-3=-12887/2169, 3-4=-12771/2190, 4-15=-6410/949, 5-15=-6272/970 BOT CHORD 1-16=-3374/13852, 10-16=-3374/13852, 10-17=-3374/13852, 17-18=-3374/13852, 9-18=-3374/13852, 9-19=-2163/11911, 19-20=-2163/11911, 8-20=-2163/11911, 8-21=-886/5615, 21-22=-886/5615, 7-22=-886/5615 WEBS 2-10=-1190/2578, 2-9=-2135/1329, 4-9=-1362/7477, 4-8=-8176/1664, 5-8=-1637/10749, 5-7=-10269/1621 NOTES- 1) 3-ply truss to be connected togetherwith 10d (0.131"x3") nails as follows: Topchordsconnected as follows: 2x6- 2 rowsstaggered at 0-7-0 oc, 2x4- 1 row at 0-9-0 oc. Bottomchordsconnected as follows: 2x8- 4 rowsstaggered at 0-5-0 oc. Websconnected as follows: 2x4- 1 row at 0-9-0 oc.2)Allloads areconsidered equally applied to all plies, exceptif noted as front(F) or back(B) facein the LOAD CASE(S)section.Ply to plyconnections have been provided to distribute onlyloads noted as(F) or(B), unless otherwiseindicated. 3) Unbalancedroofliveloads have been considered for this design.4)Wind:ASCE 7-10;Vult=115mph(3-second gust)Vasd=91mph;TCDL=6.0psf;BCDL=6.0psf; h=25ft; Cat. II;Exp C; enclosed; MWFRS(envelope) gable end zone;cantileverleft exposed ; end verticalleft exposed; Lumber DOL=1.60 plate grip DOL=1.60 5)TCLL:ASCE 7-10;Pr=20.0 psf(roofliveload: Lumber DOL=1.15Plate DOL=1.15);Pg=20.0 psf(groundsnow);Pf=20.4 psf(flatroofsnow: Lumber DOL=1.15Plate DOL=1.15); CategoryII;Exp C; PartiallyExp.; Ct=1.1, Lu=50-0-0;Min. flatroofsnowload governs. Rainsurcharge applied to all exposedsurfaceswithslopesless than 0.500/12 in accordancewithIBC 1608.3.4. 6) Unbalancedsnowloads have been considered for this design.7)Provide adequate drainage to preventwater ponding. 8)This truss has been designed for a 10.0 psf bottomchordliveload nonconcurrentwith any otherliveloads. 9)Providemechanicalconnection(by others) of truss to bearing platecapable of withstanding 100 lb uplift at joint(s) except(jt=lb) 7=1687, 1=2011. 10)This trussis designedin accordancewith the 2012 InternationalBuilding Code section 2306.1 and referencedstandardANSI/TPI 1.Continued on page 2 DE Job # 59223-W1 Dansco Engineering, LLC Date: 6/13/18 WARNING – VERIFY DESIGN PARAMETERS AND READ NOTES BEFORE FABRICATION AND INSTALLATION!!! This truss design is adequate for the design parameters shown. Review and approval of design parameters is the responsibility of the building designer, not the truss designer or truss engineer. Permanent bracing requirements against out-of-plane buckling are noted/shown for individual truss members (and for the truss as a whole) subjected to gravity and wind loads. Additional permanent bracing design shall be the responsibility of the design professional of record. Temporary and erection bracing shall be the responsibility of the contractor. Reference ANSI/TPI-1, “National Design Standard for Metal Plate Connected Wood Truss Construction” and TPI/WTCA BCSI-06, “Building Component Safety Information Guide to Good Practice for Handling, Installing, Restraining and Bracing of Metal Plate Connected Wood Trusses” for additional information. Job 1802242-12T Truss T46 TrussType HALFHIPGIRDER Qty 1 Ply 3 1802242-12TDWHWoodside-West Clay- 4 Job Reference (optional)Run:8.200 s Apr72018 Print:8.200 s Apr72018MiTekIndustries,Inc.Tue Jun1221:13:002018 Page2ID:bRTO9oDnRLEHvJjVgeMKW3yF_s1-wFesLK2fQDW1Ag_3qKRs7?xtvFFiGLvQLEUyaRz6wFX NOTES- 11) Hanger(s) or otherconnection device(s)shall be providedsufficient to supportconcentratedload(s) 103 lb down and 94 lb up at 0-0-0 on top chord, and 49 lb down at 2-6-0, 3238 lb down and 1630 lb up at 4-4-8, 2153 lb down and 300 lb up at 6-6-0, 2153 lb down and 241 lb up at 8-6-0, 2153 lb down and 227 lb up at 10-6-0, 2167 lb down and 258 lb up at 12-6-0, 2232 lb down and 286 lb up at 14-6-0, and 2206 lb down and 275 lb up at 16-6-0, and 1736 lb down and 246 lb up at 18-6-0 on bottomchord.The design/selection of suchconnection device(s)is the responsibility of others. LOADCASE(S)Standard 1) Dead +Snow(balanced): LumberIncrease=1.15,PlateIncrease=1.15 Uniform Loads(plf) Vert: 1-5=-51, 5-6=-61, 7-11=-20 Concentrated Loads(lb) Vert: 1=-36 10=-3085(F) 8=-2232(F) 16=-41(F) 17=-2120(F) 18=-2055(F) 19=-2102(F) 20=-2167(F) 21=-2206(F) 22=-1736(F) DE Job # 59223-W1 Dansco Engineering, LLC Date: 6/13/18 WARNING – VERIFY DESIGN PARAMETERS AND READ NOTES BEFORE FABRICATION AND INSTALLATION!!! This truss design is adequate for the design parameters shown. Review and approval of design parameters is the responsibility of the building designer, not the truss designer or truss engineer. Permanent bracing requirements against out-of-plane buckling are noted/shown for individual truss members (and for the truss as a whole) subjected to gravity and wind loads. Additional permanent bracing design shall be the responsibility of the design professional of record. Temporary and erection bracing shall be the responsibility of the contractor. Reference ANSI/TPI-1, “National Design Standard for Metal Plate Connected Wood Truss Construction” and TPI/WTCA BCSI-06, “Building Component Safety Information Guide to Good Practice for Handling, Installing, Restraining and Bracing of Metal Plate Connected Wood Trusses” for additional information. Job 1802242-12T Truss V01 TrussType Valley Qty 1 Ply 1 1802242-12TDWHWoodside-West Clay- 4 Job Reference (optional)Run:8.200 s Apr72018 Print:8.200 s Apr72018MiTekIndustries,Inc.Tue Jun1221:13:012018 Page1ID:bRTO9oDnRLEHvJjVgeMKW3yF_s1-ORCFYg3IBWeuopZFN1y6gCUC2eil?__ZauDW6tz6wFW Scale=1:43.5 T1 T1 B1 ST2 ST1 ST1 B21 2 3 4 5 9 8 7 6 10 11 12 13 14 15 3x4 4x4 3x4 3x4 1.5x4 1.5x4 1.5x4 1.5x4 1.5x4 0-0-5 0-0-5 17-4-0 17-3-11 8-8-0 8-8-0 17-4-0 8-8-0 0 -0 -4 6 -6 -0 0 -0 -4 9.0012 LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 10.0 SPACING- PlateGrip DOL Lumber DOL RepStressIncr Code 2-0-0 1.15 1.15 YES IBC2012/TPI2007 CSI. TC BC WB Matrix-SH 0.21 0.12 0.12 DEFL. Vert(LL) Vert(TL) Horz(TL) in n/a n/a 0.00 (loc) - - 5 l/defl n/a n/a n/a L/d 999 999 n/a PLATES MT20 Weight: 57 lb FT= 20% GRIP 197/144 LUMBER- TOP CHORD2x4SPF No.2 BOT CHORD2x4SPF No.2OTHERS2x4SPFStud BRACING- TOP CHORD Structuralwoodsheathing directly applied or 6-0-0 oc purlins. BOT CHORD Rigidceiling directly applied or 10-0-0 oc bracing. MiTekrecommends that Stabilizers and requiredcross bracing beinstalled during truss erection,in accordancewithStabilizer Installation guide. REACTIONS.All bearings 17-3-5.(lb)-Max Horz1=161(LC 13) Max UpliftAll uplift 100 lb orless at joint(s) 1 except 9=-201(LC 16), 6=-201(LC 17) MaxGravAllreactions 250 lb orless at joint(s) 1, 5, 7 except 9=430(LC 29), 6=430(LC 30) FORCES.(lb)-Max. Comp./Max.Ten.-All forces 250 (lb) orless exceptwhenshown. WEBS 2-9=-327/238, 4-6=-327/238 NOTES- 1) Unbalancedroofliveloads have been considered for this design.2)Wind:ASCE 7-10;Vult=115mph(3-second gust)Vasd=91mph;TCDL=6.0psf;BCDL=6.0psf; h=25ft; Cat. II;Exp C; enclosed; MWFRS(envelope) gable end zone and C-CExterior(2) 0-5-4 to 3-5-4,Interior(1) 3-5-4 to 8-8-0,Exterior(2) 8-8-0 to 11-8-0zone; cantileverleft and right exposed ; end verticalleft and right exposed;C-C formembers and forces&MWFRS forreactionsshown; Lumber DOL=1.60 plate grip DOL=1.60 3)TCLL:ASCE 7-10;Pr=20.0 psf(roofliveload: Lumber DOL=1.15Plate DOL=1.15);Pg=20.0 psf(groundsnow);Pf=15.4 psf(flat roofsnow: Lumber DOL=1.15Plate DOL=1.15); CategoryII;Exp C; PartiallyExp.; Ct=1.1 4) Unbalancedsnowloads have been considered for this design. 5)Gablerequirescontinuous bottomchord bearing. 6)This truss has been designed for a 10.0 psf bottomchordliveload nonconcurrentwith any otherliveloads. 7)Providemechanicalconnection(by others) of truss to bearing platecapable of withstanding 100 lb uplift at joint(s) 1 except(jt=lb) 9=201, 6=201. 8)This trussis designedin accordancewith the 2012 InternationalBuilding Code section 2306.1 and referencedstandardANSI/TPI 1. LOADCASE(S)Standard DE Job # 59223-W1 Dansco Engineering, LLC Date: 6/13/18 WARNING – VERIFY DESIGN PARAMETERS AND READ NOTES BEFORE FABRICATION AND INSTALLATION!!! This truss design is adequate for the design parameters shown. Review and approval of design parameters is the responsibility of the building designer, not the truss designer or truss engineer. Permanent bracing requirements against out-of-plane buckling are noted/shown for individual truss members (and for the truss as a whole) subjected to gravity and wind loads. Additional permanent bracing design shall be the responsibility of the design professional of record. Temporary and erection bracing shall be the responsibility of the contractor. Reference ANSI/TPI-1, “National Design Standard for Metal Plate Connected Wood Truss Construction” and TPI/WTCA BCSI-06, “Building Component Safety Information Guide to Good Practice for Handling, Installing, Restraining and Bracing of Metal Plate Connected Wood Trusses” for additional information. Job 1802242-12T Truss V02 TrussType Valley Qty 1 Ply 1 1802242-12TDWHWoodside-West Clay- 4 Job Reference (optional)Run:8.200 s Apr72018 Print:8.200 s Apr72018MiTekIndustries,Inc.Tue Jun1221:13:022018 Page1ID:bRTO9oDnRLEHvJjVgeMKW3yF_s1-semdl04wyqmlQz8SxlTLCQ1Oi21MkRgjoYz3eJz6wFV Scale=1:35.5 T1 T1 B1 ST2 ST1 ST1 1 2 3 4 5 8 7 6 9 10 11 12 3x4 4x4 3x4 1.5x41.5x4 1.5x4 1.5x4 1.5x4 14-7-11 14-7-11 14-8-0 0-0-5 7-4-0 7-4-0 14-8-0 7-4-0 0 -0 -4 5 -6 -0 0 -0 -4 9.0012 LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 10.0 SPACING- PlateGrip DOL Lumber DOL RepStressIncr Code 2-0-0 1.15 1.15 YES IBC2012/TPI2007 CSI. TC BC WB Matrix-SH 0.15 0.10 0.09 DEFL. Vert(LL) Vert(TL) Horz(TL) in n/a n/a 0.00 (loc) - - 5 l/defl n/a n/a n/a L/d 999 999 n/a PLATES MT20 Weight: 46 lb FT= 20% GRIP 197/144 LUMBER- TOP CHORD2x4SPF No.2 BOT CHORD2x4SPF No.2OTHERS2x4SPFStud BRACING- TOP CHORD Structuralwoodsheathing directly applied or 6-0-0 oc purlins. BOT CHORD Rigidceiling directly applied or 10-0-0 oc bracing. MiTekrecommends that Stabilizers and requiredcross bracing beinstalled during truss erection,in accordancewithStabilizer Installation guide. REACTIONS.All bearings 14-7-5.(lb)-Max Horz1=135(LC 13) Max UpliftAll uplift 100 lb orless at joint(s) 1 except 8=-169(LC 16), 6=-169(LC 17) MaxGravAllreactions 250 lb orless at joint(s) 1, 5, 7 except 8=355(LC 29), 6=355(LC 30) FORCES.(lb)-Max. Comp./Max.Ten.-All forces 250 (lb) orless exceptwhenshown. WEBS 2-8=-282/208, 4-6=-282/207 NOTES- 1) Unbalancedroofliveloads have been considered for this design.2)Wind:ASCE 7-10;Vult=115mph(3-second gust)Vasd=91mph;TCDL=6.0psf;BCDL=6.0psf; h=25ft; Cat. II;Exp C; enclosed; MWFRS(envelope) gable end zone and C-CExterior(2) 0-5-4 to 3-4-0,Interior(1) 3-4-0 to 7-4-0,Exterior(2) 7-4-0 to 10-4-0zone; cantileverleft and right exposed ; end verticalleft and right exposed;C-C formembers and forces&MWFRS forreactionsshown; Lumber DOL=1.60 plate grip DOL=1.60 3)TCLL:ASCE 7-10;Pr=20.0 psf(roofliveload: Lumber DOL=1.15Plate DOL=1.15);Pg=20.0 psf(groundsnow);Pf=15.4 psf(flat roofsnow: Lumber DOL=1.15Plate DOL=1.15); CategoryII;Exp C; PartiallyExp.; Ct=1.1 4) Unbalancedsnowloads have been considered for this design. 5)Gablerequirescontinuous bottomchord bearing. 6)This truss has been designed for a 10.0 psf bottomchordliveload nonconcurrentwith any otherliveloads. 7)Providemechanicalconnection(by others) of truss to bearing platecapable of withstanding 100 lb uplift at joint(s) 1 except(jt=lb) 8=169, 6=169. 8)This trussis designedin accordancewith the 2012 InternationalBuilding Code section 2306.1 and referencedstandardANSI/TPI 1. LOADCASE(S)Standard DE Job # 59223-W1 Dansco Engineering, LLC Date: 6/13/18 WARNING – VERIFY DESIGN PARAMETERS AND READ NOTES BEFORE FABRICATION AND INSTALLATION!!! This truss design is adequate for the design parameters shown. Review and approval of design parameters is the responsibility of the building designer, not the truss designer or truss engineer. Permanent bracing requirements against out-of-plane buckling are noted/shown for individual truss members (and for the truss as a whole) subjected to gravity and wind loads. Additional permanent bracing design shall be the responsibility of the design professional of record. Temporary and erection bracing shall be the responsibility of the contractor. Reference ANSI/TPI-1, “National Design Standard for Metal Plate Connected Wood Truss Construction” and TPI/WTCA BCSI-06, “Building Component Safety Information Guide to Good Practice for Handling, Installing, Restraining and Bracing of Metal Plate Connected Wood Trusses” for additional information. Job 1802242-12T Truss V03 TrussType Valley Qty 1 Ply 1 1802242-12TDWHWoodside-West Clay- 4 Job Reference (optional)Run:8.200 s Apr72018 Print:8.200 s Apr72018MiTekIndustries,Inc.Tue Jun1221:13:032018 Page1ID:bRTO9oDnRLEHvJjVgeMKW3yF_s1-KqK?zM5Yi8uc17jeVS_aldZZ1SNVTuMs1CicBmz6wFU Scale=1:29.1 T1 T1 B1 ST2 ST1 ST1 1 2 3 4 5 8 7 6 9 10 11 12 13 14 3x4 4x4 3x4 1.5x41.5x4 1.5x4 1.5x4 1.5x4 11-11-11 11-11-11 12-0-0 0-0-5 6-0-0 6-0-0 12-0-0 6-0-0 0 -0 -4 4 -6 -0 0 -0 -4 9.0012 LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 10.0 SPACING- PlateGrip DOL Lumber DOL RepStressIncr Code 2-0-0 1.15 1.15 YES IBC2012/TPI2007 CSI. TC BC WB Matrix-P 0.18 0.10 0.07 DEFL. Vert(LL) Vert(TL) Horz(TL) in n/a n/a 0.00 (loc) - - 5 l/defl n/a n/a n/a L/d 999 999 n/a PLATES MT20 Weight: 36 lb FT= 20% GRIP 197/144 LUMBER- TOP CHORD2x4SPF No.2 BOT CHORD2x4SPF No.2OTHERS2x4SPFStud BRACING- TOP CHORD Structuralwoodsheathing directly applied or 6-0-0 oc purlins. BOT CHORD Rigidceiling directly applied or 10-0-0 oc bracing. MiTekrecommends that Stabilizers and requiredcross bracing beinstalled during truss erection,in accordancewithStabilizer Installation guide. REACTIONS.All bearings 11-11-5.(lb)-Max Horz1=-109(LC 12) Max UpliftAll uplift 100 lb orless at joint(s) 1, 5 except 8=-174(LC 16), 6=-174(LC 17) MaxGravAllreactions 250 lb orless at joint(s) 1, 5, 7 except 8=343(LC 29), 6=343(LC 30) FORCES.(lb)-Max. Comp./Max.Ten.-All forces 250 (lb) orless exceptwhenshown. WEBS 2-8=-295/213, 4-6=-295/213 NOTES- 1) Unbalancedroofliveloads have been considered for this design.2)Wind:ASCE 7-10;Vult=115mph(3-second gust)Vasd=91mph;TCDL=6.0psf;BCDL=6.0psf; h=25ft; Cat. II;Exp C; enclosed; MWFRS(envelope) gable end zone and C-CExterior(2) 0-5-4 to 3-5-4,Interior(1) 3-5-4 to 6-0-0,Exterior(2) 6-0-0 to 9-0-0zone; cantileverleft and right exposed ; end verticalleft and right exposed;C-C formembers and forces&MWFRS forreactionsshown; Lumber DOL=1.60 plate grip DOL=1.60 3)TCLL:ASCE 7-10;Pr=20.0 psf(roofliveload: Lumber DOL=1.15Plate DOL=1.15);Pg=20.0 psf(groundsnow);Pf=15.4 psf(flat roofsnow: Lumber DOL=1.15Plate DOL=1.15); CategoryII;Exp C; PartiallyExp.; Ct=1.1 4) Unbalancedsnowloads have been considered for this design. 5)Gablerequirescontinuous bottomchord bearing. 6)This truss has been designed for a 10.0 psf bottomchordliveload nonconcurrentwith any otherliveloads. 7)Providemechanicalconnection(by others) of truss to bearing platecapable of withstanding 100 lb uplift at joint(s) 1, 5 except(jt=lb) 8=174, 6=174. 8)This trussis designedin accordancewith the 2012 InternationalBuilding Code section 2306.1 and referencedstandardANSI/TPI 1. LOADCASE(S)Standard DE Job # 59223-W1 Dansco Engineering, LLC Date: 6/13/18 WARNING – VERIFY DESIGN PARAMETERS AND READ NOTES BEFORE FABRICATION AND INSTALLATION!!! This truss design is adequate for the design parameters shown. Review and approval of design parameters is the responsibility of the building designer, not the truss designer or truss engineer. Permanent bracing requirements against out-of-plane buckling are noted/shown for individual truss members (and for the truss as a whole) subjected to gravity and wind loads. Additional permanent bracing design shall be the responsibility of the design professional of record. Temporary and erection bracing shall be the responsibility of the contractor. Reference ANSI/TPI-1, “National Design Standard for Metal Plate Connected Wood Truss Construction” and TPI/WTCA BCSI-06, “Building Component Safety Information Guide to Good Practice for Handling, Installing, Restraining and Bracing of Metal Plate Connected Wood Trusses” for additional information. Job 1802242-12T Truss V04 TrussType Valley Qty 1 Ply 1 1802242-12TDWHWoodside-West Clay- 4 Job Reference (optional)Run:8.200 s Apr72018 Print:8.200 s Apr72018MiTekIndustries,Inc.Tue Jun1221:13:042018 Page1ID:bRTO9oDnRLEHvJjVgeMKW3yF_s1-o0uNAi5ATR0TfHHq39VpIr6iwsizCLn?GsSAjCz6wFT Scale=1:23.7 T1 T1 B1 ST1 1 2 3 4 5 6 7 8 9 10 2x4 4x4 2x41.5x4 0-0-5 0-0-5 9-4-0 9-3-11 4-8-0 4-8-0 9-4-0 4-8-0 0 -0 -4 3 -6 -0 0 -0 -4 9.0012 LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 10.0 SPACING- PlateGrip DOL Lumber DOL RepStressIncr Code 2-0-0 1.15 1.15 YES IBC2012/TPI2007 CSI. TC BC WB Matrix-P 0.29 0.15 0.05 DEFL. Vert(LL) Vert(TL) Horz(TL) in n/a n/a 0.00 (loc) - - 3 l/defl n/a n/a n/a L/d 999 999 n/a PLATES MT20 Weight: 26 lb FT= 20% GRIP 197/144 LUMBER- TOP CHORD2x4SPF No.2 BOT CHORD2x4SPF No.2OTHERS2x4SPFStud BRACING- TOP CHORD Structuralwoodsheathing directly applied or 6-0-0 oc purlins. BOT CHORD Rigidceiling directly applied or 10-0-0 oc bracing. MiTekrecommends that Stabilizers and requiredcross bracing beinstalled during truss erection,in accordancewithStabilizer Installation guide. REACTIONS.(lb/size)1=166/9-3-5(min. 0-1-8), 3=166/9-3-5(min. 0-1-8), 4=267/9-3-5(min. 0-1-8)Max Horz1=-83(LC 12) Max Uplift1=-46(LC 16), 3=-57(LC 17) MaxGrav1=190(LC 2), 3=190(LC 2), 4=296(LC 2) FORCES.(lb)-Max. Comp./Max.Ten.-All forces 250 (lb) orless exceptwhenshown. NOTES- 1) Unbalancedroofliveloads have been considered for this design. 2)Wind:ASCE 7-10;Vult=115mph(3-second gust)Vasd=91mph;TCDL=6.0psf;BCDL=6.0psf; h=25ft; Cat. II;Exp C; enclosed;MWFRS(envelope) gable end zone and C-CExterior(2) 0-5-4 to 3-5-4,Interior(1) 3-5-4 to 4-8-0,Exterior(2) 4-8-0 to 7-8-0zone; cantileverleft and right exposed ; end verticalleft and right exposed;C-C formembers and forces&MWFRS forreactionsshown; Lumber DOL=1.60 plate grip DOL=1.60 3)TCLL:ASCE 7-10;Pr=20.0 psf(roofliveload: Lumber DOL=1.15Plate DOL=1.15);Pg=20.0 psf(groundsnow);Pf=15.4 psf(flat roofsnow: Lumber DOL=1.15Plate DOL=1.15); CategoryII;Exp C; PartiallyExp.; Ct=1.1 4) Unbalancedsnowloads have been considered for this design. 5)Gablerequirescontinuous bottomchord bearing. 6)This truss has been designed for a 10.0 psf bottomchordliveload nonconcurrentwith any otherliveloads. 7)Providemechanicalconnection(by others) of truss to bearing platecapable of withstanding 100 lb uplift at joint(s) 1, 3. 8)This trussis designedin accordancewith the 2012 InternationalBuilding Code section 2306.1 and referencedstandardANSI/TPI 1. LOADCASE(S)Standard DE Job # 59223-W1 Dansco Engineering, LLC Date: 6/13/18 WARNING – VERIFY DESIGN PARAMETERS AND READ NOTES BEFORE FABRICATION AND INSTALLATION!!! This truss design is adequate for the design parameters shown. Review and approval of design parameters is the responsibility of the building designer, not the truss designer or truss engineer. Permanent bracing requirements against out-of-plane buckling are noted/shown for individual truss members (and for the truss as a whole) subjected to gravity and wind loads. Additional permanent bracing design shall be the responsibility of the design professional of record. Temporary and erection bracing shall be the responsibility of the contractor. Reference ANSI/TPI-1, “National Design Standard for Metal Plate Connected Wood Truss Construction” and TPI/WTCA BCSI-06, “Building Component Safety Information Guide to Good Practice for Handling, Installing, Restraining and Bracing of Metal Plate Connected Wood Trusses” for additional information. Job 1802242-12T Truss V05 TrussType Valley Qty 1 Ply 1 1802242-12TDWHWoodside-West Clay- 4 Job Reference (optional)Run:8.200 s Apr72018 Print:8.200 s Apr72018MiTekIndustries,Inc.Tue Jun1221:13:042018 Page1ID:bRTO9oDnRLEHvJjVgeMKW3yF_s1-o0uNAi5ATR0TfHHq39VpIr6kVsjDCL9?GsSAjCz6wFT Scale=1:17.6 T1 T1 B1 ST1 1 2 3 4 2x4 4x4 2x41.5x4 0-0-5 0-0-5 6-8-0 6-7-11 3-4-0 3-4-0 6-8-0 3-4-0 0 -0 -4 2 -6 -0 0 -0 -4 9.0012 LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 10.0 SPACING- PlateGrip DOL Lumber DOL RepStressIncr Code 2-0-0 1.15 1.15 YES IBC2012/TPI2007 CSI. TC BC WB Matrix-P 0.13 0.07 0.03 DEFL. Vert(LL) Vert(TL) Horz(TL) in n/a n/a 0.00 (loc) - - 3 l/defl n/a n/a n/a L/d 999 999 n/a PLATES MT20 Weight: 18 lb FT= 20% GRIP 197/144 LUMBER- TOP CHORD2x4SPF No.2 BOT CHORD2x4SPF No.2OTHERS2x4SPFStud BRACING- TOP CHORD Structuralwoodsheathing directly applied or 6-0-0 oc purlins. BOT CHORD Rigidceiling directly applied or 10-0-0 oc bracing. MiTekrecommends that Stabilizers and requiredcross bracing beinstalled during truss erection,in accordancewithStabilizer Installation guide. REACTIONS.(lb/size)1=114/6-7-5(min. 0-1-8), 3=114/6-7-5(min. 0-1-8), 4=183/6-7-5(min. 0-1-8)Max Horz1=57(LC 15) Max Uplift1=-32(LC 16), 3=-39(LC 17) MaxGrav1=130(LC 2), 3=130(LC 2), 4=203(LC 2) FORCES.(lb)-Max. Comp./Max.Ten.-All forces 250 (lb) orless exceptwhenshown. NOTES- 1) Unbalancedroofliveloads have been considered for this design. 2)Wind:ASCE 7-10;Vult=115mph(3-second gust)Vasd=91mph;TCDL=6.0psf;BCDL=6.0psf; h=25ft; Cat. II;Exp C; enclosed;MWFRS(envelope) gable end zone and C-CExterior(2)zone;cantileverleft and right exposed ; end verticalleft and right exposed;C-C formembers and forces&MWFRS forreactionsshown; Lumber DOL=1.60 plate grip DOL=1.60 3)TCLL:ASCE 7-10;Pr=20.0 psf(roofliveload: Lumber DOL=1.15Plate DOL=1.15);Pg=20.0 psf(groundsnow);Pf=15.4 psf(flat roofsnow: Lumber DOL=1.15Plate DOL=1.15); CategoryII;Exp C; PartiallyExp.; Ct=1.1 4) Unbalancedsnowloads have been considered for this design. 5)Gablerequirescontinuous bottomchord bearing. 6)This truss has been designed for a 10.0 psf bottomchordliveload nonconcurrentwith any otherliveloads. 7)Providemechanicalconnection(by others) of truss to bearing platecapable of withstanding 100 lb uplift at joint(s) 1, 3. 8)This trussis designedin accordancewith the 2012 InternationalBuilding Code section 2306.1 and referencedstandardANSI/TPI 1. LOADCASE(S)Standard DE Job # 59223-W1 Dansco Engineering, LLC Date: 6/13/18 WARNING – VERIFY DESIGN PARAMETERS AND READ NOTES BEFORE FABRICATION AND INSTALLATION!!! This truss design is adequate for the design parameters shown. Review and approval of design parameters is the responsibility of the building designer, not the truss designer or truss engineer. Permanent bracing requirements against out-of-plane buckling are noted/shown for individual truss members (and for the truss as a whole) subjected to gravity and wind loads. Additional permanent bracing design shall be the responsibility of the design professional of record. Temporary and erection bracing shall be the responsibility of the contractor. Reference ANSI/TPI-1, “National Design Standard for Metal Plate Connected Wood Truss Construction” and TPI/WTCA BCSI-06, “Building Component Safety Information Guide to Good Practice for Handling, Installing, Restraining and Bracing of Metal Plate Connected Wood Trusses” for additional information. Job 1802242-12T Truss V06 TrussType Valley Qty 1 Ply 1 1802242-12TDWHWoodside-West Clay- 4 Job Reference (optional)Run:8.200 s Apr72018 Print:8.200 s Apr72018MiTekIndustries,Inc.Tue Jun1221:13:052018 Page1ID:bRTO9oDnRLEHvJjVgeMKW3yF_s1-GDSlO26oEl8KHRs1ct02q2fxkG32xot9VWBjFez6wFS Scale=1:10.3 T1 T1 B1 1 2 3 2x4 3x4 2x4 3-11-11 3-11-11 4-0-0 0-0-5 2-0-0 2-0-0 4-0-0 2-0-0 0 -0 -4 1 -6 -0 0 -0 -4 9.0012 PlateOffsets(X,Y)-- [2:0-2-0,Edge] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 10.0 SPACING- PlateGrip DOL Lumber DOL RepStressIncr Code 2-0-0 1.15 1.15 YES IBC2012/TPI2007 CSI. TC BC WB Matrix-P 0.03 0.10 0.00 DEFL. Vert(LL) Vert(TL) Horz(TL) in n/a n/a 0.00 (loc) - - 3 l/defl n/a n/a n/a L/d 999 999 n/a PLATES MT20 Weight: 9 lb FT= 20% GRIP 197/144 LUMBER- TOP CHORD2x4SPF No.2BOT CHORD2x4SPF No.2 BRACING- TOP CHORD Structuralwoodsheathing directly applied or 4-0-0 oc purlins.BOT CHORD Rigidceiling directly applied or 10-0-0 oc bracing. MiTekrecommends that Stabilizers and requiredcross bracing beinstalled during truss erection,in accordancewithStabilizer Installation guide.REACTIONS.(lb/size)1=111/3-11-5(min. 0-1-8), 3=111/3-11-5(min. 0-1-8) Max Horz1=-31(LC 12) Max Uplift1=-15(LC 16), 3=-15(LC 17)MaxGrav1=125(LC 2), 3=125(LC 2) FORCES.(lb)-Max. Comp./Max.Ten.-All forces 250 (lb) orless exceptwhenshown. NOTES- 1) Unbalancedroofliveloads have been considered for this design.2)Wind:ASCE 7-10;Vult=115mph(3-second gust)Vasd=91mph;TCDL=6.0psf;BCDL=6.0psf; h=25ft; Cat. II;Exp C; enclosed; MWFRS(envelope) gable end zone and C-CExterior(2)zone;cantileverleft and right exposed ; end verticalleft and right exposed;C-C formembers and forces&MWFRS forreactionsshown; Lumber DOL=1.60 plate grip DOL=1.60 3)TCLL:ASCE 7-10;Pr=20.0 psf(roofliveload: Lumber DOL=1.15Plate DOL=1.15);Pg=20.0 psf(groundsnow);Pf=15.4 psf(flat roofsnow: Lumber DOL=1.15Plate DOL=1.15); CategoryII;Exp C; PartiallyExp.; Ct=1.1 4) Unbalancedsnowloads have been considered for this design. 5)Gablerequirescontinuous bottomchord bearing. 6)This truss has been designed for a 10.0 psf bottomchordliveload nonconcurrentwith any otherliveloads. 7)Providemechanicalconnection(by others) of truss to bearing platecapable of withstanding 100 lb uplift at joint(s) 1, 3. 8)This trussis designedin accordancewith the 2012 InternationalBuilding Code section 2306.1 and referencedstandardANSI/TPI 1. LOADCASE(S)Standard DE Job # 59223-W1 Dansco Engineering, LLC Date: 6/13/18 WARNING – VERIFY DESIGN PARAMETERS AND READ NOTES BEFORE FABRICATION AND INSTALLATION!!! This truss design is adequate for the design parameters shown. Review and approval of design parameters is the responsibility of the building designer, not the truss designer or truss engineer. Permanent bracing requirements against out-of-plane buckling are noted/shown for individual truss members (and for the truss as a whole) subjected to gravity and wind loads. Additional permanent bracing design shall be the responsibility of the design professional of record. Temporary and erection bracing shall be the responsibility of the contractor. Reference ANSI/TPI-1, “National Design Standard for Metal Plate Connected Wood Truss Construction” and TPI/WTCA BCSI-06, “Building Component Safety Information Guide to Good Practice for Handling, Installing, Restraining and Bracing of Metal Plate Connected Wood Trusses” for additional information. Job 1802242-12T Truss V07 TrussType Valley Qty 1 Ply 1 1802242-12TDWHWoodside-West Clay- 4 Job Reference (optional)Run:8.200 s Apr72018 Print:8.200 s Apr72018MiTekIndustries,Inc.Tue Jun1221:13:062018 Page1ID:bRTO9oDnRLEHvJjVgeMKW3yF_s1-kP?8bO7Q?3GAubRDAaYHNGB4MfPIgDFIjAxGn4z6wFR Scale=1:48.6 T1 T1 B1 ST3 ST2 ST1 ST2 ST1 B2 1 2 3 4 5 6 7 13 12 11 10 9 8 14 15 16 17 18 19 3x4 4x4 3x4 3x4 20-3-11 20-3-11 20-4-0 0-0-5 10-2-0 10-2-0 20-4-0 10-2-0 0 -0 -4 7 -7 -8 0 -0 -4 9.0012 LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 10.0 SPACING- PlateGrip DOL Lumber DOL RepStressIncr Code 2-0-0 1.15 1.15 YES IBC2012/TPI2007 CSI. TC BC WB Matrix-SH 0.17 0.10 0.18 DEFL. Vert(LL) Vert(TL) Horz(TL) in n/a n/a 0.00 (loc) - - 7 l/defl n/a n/a n/a L/d 999 999 n/a PLATES MT20 Weight: 71 lb FT= 20% GRIP 197/144 LUMBER- TOP CHORD2x4SPF No.2 BOT CHORD2x4SPF No.2OTHERS2x4SPFStud BRACING- TOP CHORD Structuralwoodsheathing directly applied or 6-0-0 oc purlins. BOT CHORD Rigidceiling directly applied or 10-0-0 oc bracing. MiTekrecommends that Stabilizers and requiredcross bracing beinstalled during truss erection,in accordancewithStabilizer Installation guide. REACTIONS.All bearings 20-3-5.(lb)-Max Horz1=-191(LC 12) Max UpliftAll uplift 100 lb orless at joint(s) 1, 7 except 11=-180(LC 16), 13=-128(LC 16), 9=-179(LC 17), 8=-128(LC 17)MaxGravAllreactions 250 lb orless at joint(s) 1, 7, 10 except 11=381(LC 29), 13=285(LC 29), 9=381(LC 30), 8=285(LC 30) FORCES.(lb)-Max. Comp./Max.Ten.-All forces 250 (lb) orless exceptwhenshown. WEBS 3-11=-305/229, 5-9=-305/229 NOTES- 1) Unbalancedroofliveloads have been considered for this design. 2)Wind:ASCE 7-10;Vult=115mph(3-second gust)Vasd=91mph;TCDL=6.0psf;BCDL=6.0psf; h=25ft; Cat. II;Exp C; enclosed; MWFRS(envelope) gable end zone and C-CExterior(2) 0-5-4 to 3-5-4,Interior(1) 3-5-4 to 10-2-0,Exterior(2) 10-2-0 to 13-2-0zone; cantileverleft and right exposed ; end verticalleft and right exposed;C-C formembers and forces&MWFRS forreactionsshown; Lumber DOL=1.60 plate grip DOL=1.60 3)TCLL:ASCE 7-10;Pr=20.0 psf(roofliveload: Lumber DOL=1.15Plate DOL=1.15);Pg=20.0 psf(groundsnow);Pf=15.4 psf(flat roofsnow: Lumber DOL=1.15Plate DOL=1.15); CategoryII;Exp C; PartiallyExp.; Ct=1.1 4) Unbalancedsnowloads have been considered for this design. 5)All plates are 1.5x4MT20 unless otherwiseindicated. 6)Gablerequirescontinuous bottomchord bearing. 7)This truss has been designed for a 10.0 psf bottomchordliveload nonconcurrentwith any otherliveloads. 8)Providemechanicalconnection(by others) of truss to bearing platecapable of withstanding 100 lb uplift at joint(s) 1, 7 except(jt=lb)11=180, 13=128, 9=179, 8=128. 9)This trussis designedin accordancewith the 2012 InternationalBuilding Code section 2306.1 and referencedstandardANSI/TPI 1. LOADCASE(S)Standard DE Job # 59223-W1 Dansco Engineering, LLC Date: 6/13/18 WARNING – VERIFY DESIGN PARAMETERS AND READ NOTES BEFORE FABRICATION AND INSTALLATION!!! This truss design is adequate for the design parameters shown. Review and approval of design parameters is the responsibility of the building designer, not the truss designer or truss engineer. Permanent bracing requirements against out-of-plane buckling are noted/shown for individual truss members (and for the truss as a whole) subjected to gravity and wind loads. Additional permanent bracing design shall be the responsibility of the design professional of record. Temporary and erection bracing shall be the responsibility of the contractor. Reference ANSI/TPI-1, “National Design Standard for Metal Plate Connected Wood Truss Construction” and TPI/WTCA BCSI-06, “Building Component Safety Information Guide to Good Practice for Handling, Installing, Restraining and Bracing of Metal Plate Connected Wood Trusses” for additional information. Job 1802242-12T Truss V08 TrussType Valley Qty 1 Ply 1 1802242-12TDWHWoodside-West Clay- 4 Job Reference (optional)Run:8.200 s Apr72018 Print:8.200 s Apr72018MiTekIndustries,Inc.Tue Jun1221:13:072018 Page1ID:bRTO9oDnRLEHvJjVgeMKW3yF_s1-CbZWpk82mMP1Wk0PkI3WvTkEO3k2PhQSyqgqKXz6wFQ Scale=1:44.3 T1 T1 B1 ST2 ST1 ST1 B2 1 2 3 4 5 9 8 7 6 10 11 12 13 14 15 3x4 4x4 3x4 3x4 1.5x4 1.5x4 1.5x4 1.5x4 1.5x4 0-0-5 0-0-5 17-8-0 17-7-11 8-10-0 8-10-0 17-8-0 8-10-0 0 -0 -4 6 -7 -8 0 -0 -4 9.0012 LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 10.0 SPACING- PlateGrip DOL Lumber DOL RepStressIncr Code 2-0-0 1.15 1.15 YES IBC2012/TPI2007 CSI. TC BC WB Matrix-SH 0.22 0.13 0.12 DEFL. Vert(LL) Vert(TL) Horz(TL) in n/a n/a 0.00 (loc) - - 5 l/defl n/a n/a n/a L/d 999 999 n/a PLATES MT20 Weight: 58 lb FT= 20% GRIP 197/144 LUMBER- TOP CHORD2x4SPF No.2 BOT CHORD2x4SPF No.2OTHERS2x4SPFStud BRACING- TOP CHORD Structuralwoodsheathing directly applied or 6-0-0 oc purlins. BOT CHORD Rigidceiling directly applied or 10-0-0 oc bracing. MiTekrecommends that Stabilizers and requiredcross bracing beinstalled during truss erection,in accordancewithStabilizer Installation guide. REACTIONS.All bearings 17-7-5.(lb)-Max Horz1=164(LC 13) Max UpliftAll uplift 100 lb orless at joint(s) 1 except 9=-206(LC 16), 6=-206(LC 17) MaxGravAllreactions 250 lb orless at joint(s) 1, 5, 7 except 9=441(LC 29), 6=441(LC 30) FORCES.(lb)-Max. Comp./Max.Ten.-All forces 250 (lb) orless exceptwhenshown. WEBS 2-9=-334/243, 4-6=-334/243 NOTES- 1) Unbalancedroofliveloads have been considered for this design.2)Wind:ASCE 7-10;Vult=115mph(3-second gust)Vasd=91mph;TCDL=6.0psf;BCDL=6.0psf; h=25ft; Cat. II;Exp C; enclosed; MWFRS(envelope) gable end zone and C-CExterior(2) 0-5-4 to 3-5-4,Interior(1) 3-5-4 to 8-10-0,Exterior(2) 8-10-0 to 11-10-0 zone;cantileverleft and right exposed ; end verticalleft and right exposed;C-C formembers and forces&MWFRS forreactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3)TCLL:ASCE 7-10;Pr=20.0 psf(roofliveload: Lumber DOL=1.15Plate DOL=1.15);Pg=20.0 psf(groundsnow);Pf=15.4 psf(flat roofsnow: Lumber DOL=1.15Plate DOL=1.15); CategoryII;Exp C; PartiallyExp.; Ct=1.1 4) Unbalancedsnowloads have been considered for this design. 5)Gablerequirescontinuous bottomchord bearing. 6)This truss has been designed for a 10.0 psf bottomchordliveload nonconcurrentwith any otherliveloads. 7)Providemechanicalconnection(by others) of truss to bearing platecapable of withstanding 100 lb uplift at joint(s) 1 except(jt=lb) 9=206, 6=206. 8)This trussis designedin accordancewith the 2012 InternationalBuilding Code section 2306.1 and referencedstandardANSI/TPI 1. LOADCASE(S)Standard DE Job # 59223-W1 Dansco Engineering, LLC Date: 6/13/18 WARNING – VERIFY DESIGN PARAMETERS AND READ NOTES BEFORE FABRICATION AND INSTALLATION!!! This truss design is adequate for the design parameters shown. Review and approval of design parameters is the responsibility of the building designer, not the truss designer or truss engineer. Permanent bracing requirements against out-of-plane buckling are noted/shown for individual truss members (and for the truss as a whole) subjected to gravity and wind loads. Additional permanent bracing design shall be the responsibility of the design professional of record. Temporary and erection bracing shall be the responsibility of the contractor. Reference ANSI/TPI-1, “National Design Standard for Metal Plate Connected Wood Truss Construction” and TPI/WTCA BCSI-06, “Building Component Safety Information Guide to Good Practice for Handling, Installing, Restraining and Bracing of Metal Plate Connected Wood Trusses” for additional information. Job 1802242-12T Truss V09 TrussType Valley Qty 1 Ply 1 1802242-12TDWHWoodside-West Clay- 4 Job Reference (optional)Run:8.200 s Apr72018 Print:8.200 s Apr72018MiTekIndustries,Inc.Tue Jun1221:13:082018 Page1ID:bRTO9oDnRLEHvJjVgeMKW3yF_s1-hn7u038hXgXu8ubbI?alShGQ9T4o885bBUQNszz6wFP Scale=1:36.3 T1 T1 B1 ST2 ST1 ST1 1 2 3 4 5 8 7 6 9 10 11 12 3x4 4x4 3x4 1.5x41.5x4 1.5x4 1.5x4 1.5x4 14-11-11 14-11-11 15-0-0 0-0-5 7-6-0 7-6-0 15-0-0 7-6-0 0 -0 -4 5 -7 -8 0 -0 -4 9.0012 LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 10.0 SPACING- PlateGrip DOL Lumber DOL RepStressIncr Code 2-0-0 1.15 1.15 YES IBC2012/TPI2007 CSI. TC BC WB Matrix-SH 0.15 0.10 0.10 DEFL. Vert(LL) Vert(TL) Horz(TL) in n/a n/a 0.00 (loc) - - 5 l/defl n/a n/a n/a L/d 999 999 n/a PLATES MT20 Weight: 48 lb FT= 20% GRIP 197/144 LUMBER- TOP CHORD2x4SPF No.2 BOT CHORD2x4SPF No.2OTHERS2x4SPFStud BRACING- TOP CHORD Structuralwoodsheathing directly applied or 6-0-0 oc purlins. BOT CHORD Rigidceiling directly applied or 10-0-0 oc bracing. MiTekrecommends that Stabilizers and requiredcross bracing beinstalled during truss erection,in accordancewithStabilizer Installation guide. REACTIONS.All bearings 14-11-5.(lb)-Max Horz1=-138(LC 12) Max UpliftAll uplift 100 lb orless at joint(s) 1 except 8=-173(LC 16), 6=-173(LC 17) MaxGravAllreactions 250 lb orless at joint(s) 1, 5, 7 except 8=363(LC 29), 6=363(LC 30) FORCES.(lb)-Max. Comp./Max.Ten.-All forces 250 (lb) orless exceptwhenshown. WEBS 2-8=-286/211, 4-6=-286/210 NOTES- 1) Unbalancedroofliveloads have been considered for this design.2)Wind:ASCE 7-10;Vult=115mph(3-second gust)Vasd=91mph;TCDL=6.0psf;BCDL=6.0psf; h=25ft; Cat. II;Exp C; enclosed; MWFRS(envelope) gable end zone and C-CExterior(2) 0-5-4 to 3-6-0,Interior(1) 3-6-0 to 7-6-0,Exterior(2) 7-6-0 to 10-6-0zone; cantileverleft and right exposed ; end verticalleft and right exposed;C-C formembers and forces&MWFRS forreactionsshown; Lumber DOL=1.60 plate grip DOL=1.60 3)TCLL:ASCE 7-10;Pr=20.0 psf(roofliveload: Lumber DOL=1.15Plate DOL=1.15);Pg=20.0 psf(groundsnow);Pf=15.4 psf(flat roofsnow: Lumber DOL=1.15Plate DOL=1.15); CategoryII;Exp C; PartiallyExp.; Ct=1.1 4) Unbalancedsnowloads have been considered for this design. 5)Gablerequirescontinuous bottomchord bearing. 6)This truss has been designed for a 10.0 psf bottomchordliveload nonconcurrentwith any otherliveloads. 7)Providemechanicalconnection(by others) of truss to bearing platecapable of withstanding 100 lb uplift at joint(s) 1 except(jt=lb) 8=173, 6=173. 8)This trussis designedin accordancewith the 2012 InternationalBuilding Code section 2306.1 and referencedstandardANSI/TPI 1. LOADCASE(S)Standard DE Job # 59223-W1 Dansco Engineering, LLC Date: 6/13/18 WARNING – VERIFY DESIGN PARAMETERS AND READ NOTES BEFORE FABRICATION AND INSTALLATION!!! This truss design is adequate for the design parameters shown. Review and approval of design parameters is the responsibility of the building designer, not the truss designer or truss engineer. Permanent bracing requirements against out-of-plane buckling are noted/shown for individual truss members (and for the truss as a whole) subjected to gravity and wind loads. Additional permanent bracing design shall be the responsibility of the design professional of record. Temporary and erection bracing shall be the responsibility of the contractor. Reference ANSI/TPI-1, “National Design Standard for Metal Plate Connected Wood Truss Construction” and TPI/WTCA BCSI-06, “Building Component Safety Information Guide to Good Practice for Handling, Installing, Restraining and Bracing of Metal Plate Connected Wood Trusses” for additional information. Job 1802242-12T Truss V10 TrussType Valley Qty 1 Ply 1 1802242-12TDWHWoodside-West Clay- 4 Job Reference (optional)Run:8.200 s Apr72018 Print:8.200 s Apr72018MiTekIndustries,Inc.Tue Jun1221:13:092018 Page1ID:bRTO9oDnRLEHvJjVgeMKW3yF_s1-9_hGDP9JI_fll2Aorj5_?upb_tQvtbolP79xOPz6wFO Scale=1:29.8 T1 T1 B1 ST2 ST1 ST1 1 2 3 4 5 8 7 6 9 10 11 12 3x4 4x4 3x4 1.5x41.5x4 1.5x4 1.5x4 1.5x4 0-0-5 0-0-5 12-4-0 12-3-11 6-2-0 6-2-0 12-4-0 6-2-0 0 -0 -4 4 -7 -8 0 -0 -4 9.0012 LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 10.0 SPACING- PlateGrip DOL Lumber DOL RepStressIncr Code 2-0-0 1.15 1.15 YES IBC2012/TPI2007 CSI. TC BC WB Matrix-SH 0.15 0.10 0.07 DEFL. Vert(LL) Vert(TL) Horz(TL) in n/a n/a 0.00 (loc) - - 5 l/defl n/a n/a n/a L/d 999 999 n/a PLATES MT20 Weight: 37 lb FT= 20% GRIP 197/144 LUMBER- TOP CHORD2x4SPF No.2 BOT CHORD2x4SPF No.2OTHERS2x4SPFStud BRACING- TOP CHORD Structuralwoodsheathing directly applied or 6-0-0 oc purlins. BOT CHORD Rigidceiling directly applied or 10-0-0 oc bracing. MiTekrecommends that Stabilizers and requiredcross bracing beinstalled during truss erection,in accordancewithStabilizer Installation guide. REACTIONS.All bearings 12-3-5.(lb)-Max Horz1=-112(LC 12) Max UpliftAll uplift 100 lb orless at joint(s) 1, 5 except 8=-156(LC 16), 6=-156(LC 17) MaxGravAllreactions 250 lb orless at joint(s) 1, 5 except 7=252(LC 2), 8=320(LC 29), 6=320(LC 30) FORCES.(lb)-Max. Comp./Max.Ten.-All forces 250 (lb) orless exceptwhenshown. WEBS 2-8=-268/201, 4-6=-268/201 NOTES- 1) Unbalancedroofliveloads have been considered for this design.2)Wind:ASCE 7-10;Vult=115mph(3-second gust)Vasd=91mph;TCDL=6.0psf;BCDL=6.0psf; h=25ft; Cat. II;Exp C; enclosed; MWFRS(envelope) gable end zone and C-CExterior(2) 0-5-4 to 3-5-4,Interior(1) 3-5-4 to 6-2-0,Exterior(2) 6-2-0 to 9-2-0zone; cantileverleft and right exposed ; end verticalleft and right exposed;C-C formembers and forces&MWFRS forreactionsshown; Lumber DOL=1.60 plate grip DOL=1.60 3)TCLL:ASCE 7-10;Pr=20.0 psf(roofliveload: Lumber DOL=1.15Plate DOL=1.15);Pg=20.0 psf(groundsnow);Pf=15.4 psf(flat roofsnow: Lumber DOL=1.15Plate DOL=1.15); CategoryII;Exp C; PartiallyExp.; Ct=1.1 4) Unbalancedsnowloads have been considered for this design. 5)Gablerequirescontinuous bottomchord bearing. 6)This truss has been designed for a 10.0 psf bottomchordliveload nonconcurrentwith any otherliveloads. 7)Providemechanicalconnection(by others) of truss to bearing platecapable of withstanding 100 lb uplift at joint(s) 1, 5 except(jt=lb) 8=156, 6=156. 8)This trussis designedin accordancewith the 2012 InternationalBuilding Code section 2306.1 and referencedstandardANSI/TPI 1. LOADCASE(S)Standard DE Job # 59223-W1 Dansco Engineering, LLC Date: 6/13/18 WARNING – VERIFY DESIGN PARAMETERS AND READ NOTES BEFORE FABRICATION AND INSTALLATION!!! This truss design is adequate for the design parameters shown. Review and approval of design parameters is the responsibility of the building designer, not the truss designer or truss engineer. Permanent bracing requirements against out-of-plane buckling are noted/shown for individual truss members (and for the truss as a whole) subjected to gravity and wind loads. Additional permanent bracing design shall be the responsibility of the design professional of record. Temporary and erection bracing shall be the responsibility of the contractor. Reference ANSI/TPI-1, “National Design Standard for Metal Plate Connected Wood Truss Construction” and TPI/WTCA BCSI-06, “Building Component Safety Information Guide to Good Practice for Handling, Installing, Restraining and Bracing of Metal Plate Connected Wood Trusses” for additional information. Job 1802242-12T Truss V11 TrussType Valley Qty 1 Ply 1 1802242-12TDWHWoodside-West Clay- 4 Job Reference (optional)Run:8.200 s Apr72018 Print:8.200 s Apr72018MiTekIndustries,Inc.Tue Jun1221:13:092018 Page1ID:bRTO9oDnRLEHvJjVgeMKW3yF_s1-9_hGDP9JI_fll2Aorj5_?upYGtPytcylP79xOPz6wFO Scale=1:24.6 T1 T1 B1 ST1 1 2 3 4 5 6 7 8 9 10 2x4 4x4 2x41.5x4 0-0-5 0-0-5 9-8-0 9-7-11 4-10-0 4-10-0 9-8-0 4-10-0 0 -0 -4 3 -7 -8 0 -0 -4 9.0012 LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 10.0 SPACING- PlateGrip DOL Lumber DOL RepStressIncr Code 2-0-0 1.15 1.15 YES IBC2012/TPI2007 CSI. TC BC WB Matrix-P 0.32 0.16 0.06 DEFL. Vert(LL) Vert(TL) Horz(TL) in n/a n/a 0.00 (loc) - - 3 l/defl n/a n/a n/a L/d 999 999 n/a PLATES MT20 Weight: 27 lb FT= 20% GRIP 197/144 LUMBER- TOP CHORD2x4SPF No.2 BOT CHORD2x4SPF No.2OTHERS2x4SPFStud BRACING- TOP CHORD Structuralwoodsheathing directly applied or 6-0-0 oc purlins. BOT CHORD Rigidceiling directly applied or 10-0-0 oc bracing. MiTekrecommends that Stabilizers and requiredcross bracing beinstalled during truss erection,in accordancewithStabilizer Installation guide. REACTIONS.(lb/size)1=173/9-7-5(min. 0-1-8), 3=173/9-7-5(min. 0-1-8), 4=277/9-7-5(min. 0-1-8)Max Horz1=-86(LC 12) Max Uplift1=-48(LC 16), 3=-59(LC 17) MaxGrav1=198(LC 2), 3=198(LC 2), 4=308(LC 2) FORCES.(lb)-Max. Comp./Max.Ten.-All forces 250 (lb) orless exceptwhenshown. NOTES- 1) Unbalancedroofliveloads have been considered for this design. 2)Wind:ASCE 7-10;Vult=115mph(3-second gust)Vasd=91mph;TCDL=6.0psf;BCDL=6.0psf; h=25ft; Cat. II;Exp C; enclosed;MWFRS(envelope) gable end zone and C-CExterior(2) 0-5-4 to 3-5-4,Interior(1) 3-5-4 to 4-10-0,Exterior(2) 4-10-0 to 7-10-0zone; cantileverleft and right exposed ; end verticalleft and right exposed;C-C formembers and forces&MWFRS forreactionsshown; Lumber DOL=1.60 plate grip DOL=1.60 3)TCLL:ASCE 7-10;Pr=20.0 psf(roofliveload: Lumber DOL=1.15Plate DOL=1.15);Pg=20.0 psf(groundsnow);Pf=15.4 psf(flat roofsnow: Lumber DOL=1.15Plate DOL=1.15); CategoryII;Exp C; PartiallyExp.; Ct=1.1 4) Unbalancedsnowloads have been considered for this design. 5)Gablerequirescontinuous bottomchord bearing. 6)This truss has been designed for a 10.0 psf bottomchordliveload nonconcurrentwith any otherliveloads. 7)Providemechanicalconnection(by others) of truss to bearing platecapable of withstanding 100 lb uplift at joint(s) 1, 3. 8)This trussis designedin accordancewith the 2012 InternationalBuilding Code section 2306.1 and referencedstandardANSI/TPI 1. LOADCASE(S)Standard DE Job # 59223-W1 Dansco Engineering, LLC Date: 6/13/18 WARNING – VERIFY DESIGN PARAMETERS AND READ NOTES BEFORE FABRICATION AND INSTALLATION!!! This truss design is adequate for the design parameters shown. Review and approval of design parameters is the responsibility of the building designer, not the truss designer or truss engineer. Permanent bracing requirements against out-of-plane buckling are noted/shown for individual truss members (and for the truss as a whole) subjected to gravity and wind loads. Additional permanent bracing design shall be the responsibility of the design professional of record. Temporary and erection bracing shall be the responsibility of the contractor. Reference ANSI/TPI-1, “National Design Standard for Metal Plate Connected Wood Truss Construction” and TPI/WTCA BCSI-06, “Building Component Safety Information Guide to Good Practice for Handling, Installing, Restraining and Bracing of Metal Plate Connected Wood Trusses” for additional information. Job 1802242-12T Truss V13 TrussType Valley Qty 1 Ply 1 1802242-12TDWHWoodside-West Clay- 4 Job Reference (optional)Run:8.200 s Apr72018 Print:8.200 s Apr72018MiTekIndustries,Inc.Tue Jun1221:13:102018 Page1ID:bRTO9oDnRLEHvJjVgeMKW3yF_s1-dAFeRlAx3HncNCl_PQcDX6MmjHmVc3buenvUwsz6wFN Scale=1:18.5 T1 T1 B1 ST1 1 2 3 4 2x4 4x4 2x41.5x4 0-0-5 0-0-5 7-0-0 6-11-11 3-6-0 3-6-0 7-0-0 3-6-0 0 -0 -4 2 -7 -8 0 -0 -4 9.0012 LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 10.0 SPACING- PlateGrip DOL Lumber DOL RepStressIncr Code 2-0-0 1.15 1.15 YES IBC2012/TPI2007 CSI. TC BC WB Matrix-P 0.15 0.08 0.03 DEFL. Vert(LL) Vert(TL) Horz(TL) in n/a n/a 0.00 (loc) - - 3 l/defl n/a n/a n/a L/d 999 999 n/a PLATES MT20 Weight: 19 lb FT= 20% GRIP 197/144 LUMBER- TOP CHORD2x4SPF No.2 BOT CHORD2x4SPF No.2OTHERS2x4SPFStud BRACING- TOP CHORD Structuralwoodsheathing directly applied or 6-0-0 oc purlins. BOT CHORD Rigidceiling directly applied or 10-0-0 oc bracing. MiTekrecommends that Stabilizers and requiredcross bracing beinstalled during truss erection,in accordancewithStabilizer Installation guide. REACTIONS.(lb/size)1=120/6-11-5(min. 0-1-8), 3=120/6-11-5(min. 0-1-8), 4=193/6-11-5(min. 0-1-8)Max Horz1=-60(LC 12) Max Uplift1=-34(LC 16), 3=-41(LC 17) MaxGrav1=138(LC 2), 3=138(LC 2), 4=214(LC 2) FORCES.(lb)-Max. Comp./Max.Ten.-All forces 250 (lb) orless exceptwhenshown. NOTES- 1) Unbalancedroofliveloads have been considered for this design. 2)Wind:ASCE 7-10;Vult=115mph(3-second gust)Vasd=91mph;TCDL=6.0psf;BCDL=6.0psf; h=25ft; Cat. II;Exp C; enclosed;MWFRS(envelope) gable end zone and C-CExterior(2)zone;cantileverleft and right exposed ; end verticalleft and right exposed;C-C formembers and forces&MWFRS forreactionsshown; Lumber DOL=1.60 plate grip DOL=1.60 3)TCLL:ASCE 7-10;Pr=20.0 psf(roofliveload: Lumber DOL=1.15Plate DOL=1.15);Pg=20.0 psf(groundsnow);Pf=15.4 psf(flat roofsnow: Lumber DOL=1.15Plate DOL=1.15); CategoryII;Exp C; PartiallyExp.; Ct=1.1 4) Unbalancedsnowloads have been considered for this design. 5)Gablerequirescontinuous bottomchord bearing. 6)This truss has been designed for a 10.0 psf bottomchordliveload nonconcurrentwith any otherliveloads. 7)Providemechanicalconnection(by others) of truss to bearing platecapable of withstanding 100 lb uplift at joint(s) 1, 3. 8)This trussis designedin accordancewith the 2012 InternationalBuilding Code section 2306.1 and referencedstandardANSI/TPI 1. LOADCASE(S)Standard DE Job # 59223-W1 Dansco Engineering, LLC Date: 6/13/18 WARNING – VERIFY DESIGN PARAMETERS AND READ NOTES BEFORE FABRICATION AND INSTALLATION!!! This truss design is adequate for the design parameters shown. Review and approval of design parameters is the responsibility of the building designer, not the truss designer or truss engineer. Permanent bracing requirements against out-of-plane buckling are noted/shown for individual truss members (and for the truss as a whole) subjected to gravity and wind loads. Additional permanent bracing design shall be the responsibility of the design professional of record. Temporary and erection bracing shall be the responsibility of the contractor. Reference ANSI/TPI-1, “National Design Standard for Metal Plate Connected Wood Truss Construction” and TPI/WTCA BCSI-06, “Building Component Safety Information Guide to Good Practice for Handling, Installing, Restraining and Bracing of Metal Plate Connected Wood Trusses” for additional information. Job 1802242-12T Truss V14 TrussType Valley Qty 1 Ply 1 1802242-12TDWHWoodside-West Clay- 4 Job Reference (optional)Run:8.200 s Apr72018 Print:8.200 s Apr72018MiTekIndustries,Inc.Tue Jun1221:13:112018 Page1ID:bRTO9oDnRLEHvJjVgeMKW3yF_s1-5Mp1e5BZqbvT?MKAz87S4Juz5g64LWM1tRe1TIz6wFM Scale=1:10.9 T1 T1 B1 1 2 3 2x4 3x4 2x4 4-3-11 4-3-11 4-4-0 0-0-5 2-2-0 2-2-0 4-4-0 2-2-0 0 -0 -4 1 -7 -8 0 -0 -4 9.0012 PlateOffsets(X,Y)-- [2:0-2-0,Edge] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 10.0 SPACING- PlateGrip DOL Lumber DOL RepStressIncr Code 2-0-0 1.15 1.15 YES IBC2012/TPI2007 CSI. TC BC WB Matrix-P 0.04 0.12 0.00 DEFL. Vert(LL) Vert(TL) Horz(TL) in n/a n/a 0.00 (loc) - - 3 l/defl n/a n/a n/a L/d 999 999 n/a PLATES MT20 Weight: 10 lb FT= 20% GRIP 197/144 LUMBER- TOP CHORD2x4SPF No.2BOT CHORD2x4SPF No.2 BRACING- TOP CHORD Structuralwoodsheathing directly applied or 4-4-0 oc purlins.BOT CHORD Rigidceiling directly applied or 10-0-0 oc bracing. MiTekrecommends that Stabilizers and requiredcross bracing beinstalled during truss erection,in accordancewithStabilizer Installation guide.REACTIONS.(lb/size)1=122/4-3-5(min. 0-1-8), 3=122/4-3-5(min. 0-1-8) Max Horz1=-34(LC 12) Max Uplift1=-17(LC 16), 3=-17(LC 17)MaxGrav1=138(LC 2), 3=138(LC 2) FORCES.(lb)-Max. Comp./Max.Ten.-All forces 250 (lb) orless exceptwhenshown. NOTES- 1) Unbalancedroofliveloads have been considered for this design.2)Wind:ASCE 7-10;Vult=115mph(3-second gust)Vasd=91mph;TCDL=6.0psf;BCDL=6.0psf; h=25ft; Cat. II;Exp C; enclosed; MWFRS(envelope) gable end zone and C-CExterior(2)zone;cantileverleft and right exposed ; end verticalleft and right exposed;C-C formembers and forces&MWFRS forreactionsshown; Lumber DOL=1.60 plate grip DOL=1.60 3)TCLL:ASCE 7-10;Pr=20.0 psf(roofliveload: Lumber DOL=1.15Plate DOL=1.15);Pg=20.0 psf(groundsnow);Pf=15.4 psf(flat roofsnow: Lumber DOL=1.15Plate DOL=1.15); CategoryII;Exp C; PartiallyExp.; Ct=1.1 4) Unbalancedsnowloads have been considered for this design. 5)Gablerequirescontinuous bottomchord bearing. 6)This truss has been designed for a 10.0 psf bottomchordliveload nonconcurrentwith any otherliveloads. 7)Providemechanicalconnection(by others) of truss to bearing platecapable of withstanding 100 lb uplift at joint(s) 1, 3. 8)This trussis designedin accordancewith the 2012 InternationalBuilding Code section 2306.1 and referencedstandardANSI/TPI 1. LOADCASE(S)Standard DE Job # 59223-W1 Dansco Engineering, LLC Date: 6/13/18 WARNING – VERIFY DESIGN PARAMETERS AND READ NOTES BEFORE FABRICATION AND INSTALLATION!!! This truss design is adequate for the design parameters shown. Review and approval of design parameters is the responsibility of the building designer, not the truss designer or truss engineer. Permanent bracing requirements against out-of-plane buckling are noted/shown for individual truss members (and for the truss as a whole) subjected to gravity and wind loads. Additional permanent bracing design shall be the responsibility of the design professional of record. Temporary and erection bracing shall be the responsibility of the contractor. Reference ANSI/TPI-1, “National Design Standard for Metal Plate Connected Wood Truss Construction” and TPI/WTCA BCSI-06, “Building Component Safety Information Guide to Good Practice for Handling, Installing, Restraining and Bracing of Metal Plate Connected Wood Trusses” for additional information. Job 1802242-12T Truss V15 TrussType GABLE Qty 1 Ply 1 1802242-12TDWHWoodside-West Clay- 4 Job Reference (optional)Run:8.200 s Apr72018 Print:8.200 s Apr72018MiTekIndustries,Inc.Tue Jun1221:13:122018 Page1ID:bRTO9oDnRLEHvJjVgeMKW3yF_s1-ZZNPsRBBbv1KcWvNXrehcXR5L4Sf4w2B65Ob?kz6wFL Scale=1:81.3 0 -1 -10 0 -1 -10 T1 T2 T1 B1 ST4ST4ST4ST3 ST2 ST1 ST4 ST4 ST3 ST2 ST1 T3 B1B3B21 2 3 4 5 6 7 8 9 10 11 12 13 14 15 29 28 27 26 25 24 23 22 21 20 19 18 17 16 30 31 32 33 34 35 36 37 38 39 4x6 3x6 3x6 4x6 3x6 5x6 3x63x6 48-9-2 48-9-2 14-5-9 14-5-9 34-3-9 19-10-0 48-9-2 14-5-9 5 -10 -11 6 -0 -5 5 -10 -11 5.0012 PlateOffsets(X,Y)-- [5:0-3-0,Edge], [9:0-3-0,0-3-0], [11:0-3-0,Edge] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 10.0 SPACING- PlateGrip DOL Lumber DOL RepStressIncr Code 2-0-0 1.15 1.15 YES IBC2012/TPI2007 CSI. TC BC WB Matrix-SH 0.20 0.10 0.23 DEFL. Vert(LL) Vert(TL) Horz(TL) in n/a n/a 0.01 (loc) - - 15 l/defl n/a n/a n/a L/d 999 999 n/a PLATES MT20 Weight: 163 lb FT= 20% GRIP 197/144 LUMBER- TOP CHORD2x4SPF No.2BOT CHORD2x4SPF No.2 OTHERS 2x4SPFStud BRACING- TOP CHORD Structuralwoodsheathing directly applied or 6-0-0 oc purlins.BOT CHORD Rigidceiling directly applied or 10-0-0 oc bracing. MiTekrecommends that Stabilizers and requiredcross bracing beinstalled during truss erection,in accordancewithStabilizer Installation guide.REACTIONS.All bearings 48-9-2. (lb)-Max Horz1=-100(LC 21) Max UpliftAll uplift 100 lb orless at joint(s) 22, 23, 25, 27, 28, 21, 20, 18 except 29=-101(LC 16), 17=-101(LC 17), 16=-101(LC 17) MaxGravAllreactions 250 lb orless at joint(s) 1, 15 except 22=420(LC 37), 23=421(LC 37), 25=388(LC 37), 27=390(LC 38), 28=416(LC 38), 29=441(LC 38), 21=423(LC 37), 20=380(LC 37), 18=390(LC 38), 17=416(LC 38), 16=441(LC 38) FORCES.(lb)-Max. Comp./Max.Ten.-All forces 250 (lb) orless exceptwhenshown.WEBS 8-22=-340/114, 7-23=-341/121, 6-25=-308/92, 4-27=-309/131, 3-28=-341/152, 2-29=-342/148, 9-21=-343/122, 10-20=-301/89, 12-18=-309/130, 13-17=-341/153, 14-16=-342/148 NOTES- 1) Unbalancedroofliveloads have been considered for this design. 2)Wind:ASCE 7-10;Vult=115mph(3-second gust)Vasd=91mph;TCDL=6.0psf;BCDL=6.0psf; h=25ft; Cat. II;Exp C; enclosed; MWFRS(envelope) gable end zone and C-CExterior(2) 0-8-12 to 5-7-2,Interior(1) 5-7-2 to 14-5-9,Exterior(2) 14-5-9 to 41-2-2, Interior(1) 41-2-2 to 48-0-6zone;cantileverleft and right exposed ; end verticalleft and right exposed;C-C formembers and forces & MWFRS forreactionsshown; Lumber DOL=1.60 plate grip DOL=1.60 3)TCLL:ASCE 7-10;Pr=20.0 psf(roofliveload: Lumber DOL=1.15Plate DOL=1.15);Pg=20.0 psf(groundsnow);Pf=20.4 psf(flat roofsnow: Lumber DOL=1.15Plate DOL=1.15); CategoryII;Exp C; PartiallyExp.; Ct=1.1, Lu=50-0-0;Min. flatroofsnowload governs. Rainsurcharge applied to all exposedsurfaceswithslopesless than 0.500/12 in accordancewithIBC 1608.3.4.4) Unbalancedsnowloads have been considered for this design. 5)Provide adequate drainage to preventwater ponding. 6)All plates are 2x4MT20 unless otherwiseindicated.7)Gablerequirescontinuous bottomchord bearing. 8)This truss has been designed for a 10.0 psf bottomchordliveload nonconcurrentwith any otherliveloads. 9)Providemechanicalconnection(by others) of truss to bearing platecapable of withstanding 100 lb uplift at joint(s) 22, 23, 25, 27, 28,21, 20, 18 except(jt=lb) 29=101, 17=101, 16=101. 10)This trussis designedin accordancewith the 2012 InternationalBuilding Code section 2306.1 and referencedstandardANSI/TPI 1. LOADCASE(S)Standard DE Job # 59223-W1 Dansco Engineering, LLC Date: 6/13/18 WARNING – VERIFY DESIGN PARAMETERS AND READ NOTES BEFORE FABRICATION AND INSTALLATION!!! This truss design is adequate for the design parameters shown. Review and approval of design parameters is the responsibility of the building designer, not the truss designer or truss engineer. Permanent bracing requirements against out-of-plane buckling are noted/shown for individual truss members (and for the truss as a whole) subjected to gravity and wind loads. Additional permanent bracing design shall be the responsibility of the design professional of record. Temporary and erection bracing shall be the responsibility of the contractor. Reference ANSI/TPI-1, “National Design Standard for Metal Plate Connected Wood Truss Construction” and TPI/WTCA BCSI-06, “Building Component Safety Information Guide to Good Practice for Handling, Installing, Restraining and Bracing of Metal Plate Connected Wood Trusses” for additional information. Job 1802242-12T Truss V16 TrussType GABLE Qty 1 Ply 1 1802242-12TDWHWoodside-West Clay- 4 Job Reference (optional)Run:8.200 s Apr72018 Print:8.200 s Apr72018MiTekIndustries,Inc.Tue Jun1221:13:142018 Page1ID:bRTO9oDnRLEHvJjVgeMKW3yF_s1-VxU9H7DR7WH2sp2leGh9iyWPFu59YqXUZPti3dz6wFJ Scale=1:71.8 0 -1 -10 0 -1 -10 T1 T2 T1 B1 ST3ST3ST3 ST2 ST1 ST3 ST3 ST2 ST1 B1B21 2 3 4 5 6 7 8 9 10 11 22 21 20 19 18 17 16 15 14 13 12 23 24 25 26 2728 29 30 31 32 33 34 3x5 3x5 3x6 6x6 6x6 3x6 43-11-8 43-11-8 14-0-12 14-0-12 29-10-12 15-10-0 43-11-8 14-0-12 5 -8 -11 5 -10 -5 5 -8 -11 5.0012 LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 10.0 SPACING- PlateGrip DOL Lumber DOL RepStressIncr Code 2-0-0 1.15 1.15 YES IBC2012/TPI2007 CSI. TC BC WB Matrix-SH 0.37 0.23 0.23 DEFL. Vert(LL) Vert(TL) Horz(TL) in n/a n/a 0.01 (loc) - - 11 l/defl n/a n/a n/a L/d 999 999 n/a PLATES MT20 Weight: 143 lb FT= 20% GRIP 197/144 LUMBER- TOP CHORD2x4SPF No.2 BOT CHORD2x4SPF No.2OTHERS2x4SPFStud BRACING- TOP CHORD Structuralwoodsheathing directly applied or 6-0-0 oc purlins. BOT CHORD Rigidceiling directly applied or 10-0-0 oc bracing. MiTekrecommends that Stabilizers and requiredcross bracing beinstalled during truss erection,in accordancewithStabilizer Installation guide. REACTIONS.All bearings 43-11-8.(lb)-Max Horz1=-97(LC 17) Max UpliftAll uplift 100 lb orless at joint(s) 1, 11, 17, 18, 20, 21, 16, 14, 13 except 22=-129(LC 16), 12=-129(LC 17)MaxGravAllreactions 250 lb orless at joint(s) 1, 11 except 17=406(LC 37), 18=441(LC 37), 20=302(LC 53), 21=398(LC 38), 22=567(LC 38), 16=441(LC 37), 14=302(LC 54), 13=398(LC 38), 12=567(LC 38) FORCES.(lb)-Max. Comp./Max.Ten.-All forces 250 (lb) orless exceptwhenshown. WEBS 6-17=-326/112, 5-18=-362/126, 3-21=-339/165, 2-22=-427/174, 7-16=-362/125, 9-13=-339/165, 10-12=-427/174 NOTES- 1) Unbalancedroofliveloads have been considered for this design. 2)Wind:ASCE 7-10;Vult=115mph(3-second gust)Vasd=91mph;TCDL=6.0psf;BCDL=6.0psf; h=25ft; Cat. II;Exp C; enclosed; MWFRS(envelope) gable end zone and C-CExterior(2) 0-8-12 to 5-1-6,Interior(1) 5-1-6 to 14-0-12,Exterior(2) 14-0-12 to 36-1-3, Interior(1) 36-1-3 to 43-2-12zone;cantileverleft and right exposed ; end verticalleft and right exposed;C-C formembers and forces &MWFRS forreactionsshown; Lumber DOL=1.60 plate grip DOL=1.60 3)TCLL:ASCE 7-10;Pr=20.0 psf(roofliveload: Lumber DOL=1.15Plate DOL=1.15);Pg=20.0 psf(groundsnow);Pf=20.4 psf(flat roofsnow: Lumber DOL=1.15Plate DOL=1.15); CategoryII;Exp C; PartiallyExp.; Ct=1.1, Lu=50-0-0;Min. flatroofsnowload governs. Rainsurcharge applied to all exposedsurfaceswithslopesless than 0.500/12 in accordancewithIBC 1608.3.4. 4) Unbalancedsnowloads have been considered for this design. 5)Provide adequate drainage to preventwater ponding. 6)All plates are 1.5x4MT20 unless otherwiseindicated.7)Gablerequirescontinuous bottomchord bearing. 8)This truss has been designed for a 10.0 psf bottomchordliveload nonconcurrentwith any otherliveloads. 9)Providemechanicalconnection(by others) of truss to bearing platecapable of withstanding 100 lb uplift at joint(s) 1, 11, 17, 18, 20,21, 16, 14, 13 except(jt=lb) 22=129, 12=129. 10)This trussis designedin accordancewith the 2012 InternationalBuilding Code section 2306.1 and referencedstandardANSI/TPI 1. LOADCASE(S)Standard DE Job # 59223-W1 Dansco Engineering, LLC Date: 6/13/18 WARNING – VERIFY DESIGN PARAMETERS AND READ NOTES BEFORE FABRICATION AND INSTALLATION!!! This truss design is adequate for the design parameters shown. Review and approval of design parameters is the responsibility of the building designer, not the truss designer or truss engineer. Permanent bracing requirements against out-of-plane buckling are noted/shown for individual truss members (and for the truss as a whole) subjected to gravity and wind loads. Additional permanent bracing design shall be the responsibility of the design professional of record. Temporary and erection bracing shall be the responsibility of the contractor. Reference ANSI/TPI-1, “National Design Standard for Metal Plate Connected Wood Truss Construction” and TPI/WTCA BCSI-06, “Building Component Safety Information Guide to Good Practice for Handling, Installing, Restraining and Bracing of Metal Plate Connected Wood Trusses” for additional information. Job 1802242-12T Truss V17 TrussType GABLE Qty 1 Ply 1 1802242-12TDWHWoodside-West Clay- 4 Job Reference (optional)Run:8.200 s Apr72018 Print:8.200 s Apr72018MiTekIndustries,Inc.Tue Jun1221:13:152018 Page1ID:bRTO9oDnRLEHvJjVgeMKW3yF_s1-z82XUTE4uqPvTzdyCzCOE93cVHTQHH6do3cFc3z6wFI Scale:3/16"=1' 0 -1 -10 0 -1 -10 T1 T2 T1 B1 ST4ST4ST3 ST2 ST1 ST4 ST3 ST2 ST1B1B21 2 3 4 5 6 7 8 9 10 11 12 13 24 23 22 21 20 19 18 17 16 15 14 2526 27 28 2930 31 32 3334 3x5 3x6 3x6 3x5 3x6 3x6 39-1-14 39-1-14 13-7-15 13-7-15 25-5-15 11-10-0 39-1-14 13-7-15 5 -6 -11 5 -8 -5 5 -6 -11 5.0012 PlateOffsets(X,Y)-- [5:0-3-0,Edge], [9:0-3-0,Edge] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 10.0 SPACING- PlateGrip DOL Lumber DOL RepStressIncr Code 2-0-0 1.15 1.15 YES IBC2012/TPI2007 CSI. TC BC WB Matrix-SH 0.21 0.10 0.21 DEFL. Vert(LL) Vert(TL) Horz(TL) in n/a n/a 0.01 (loc) - - 13 l/defl n/a n/a n/a L/d 999 999 n/a PLATES MT20 Weight: 125 lb FT= 20% GRIP 197/144 LUMBER- TOP CHORD2x4SPF No.2BOT CHORD2x4SPF No.2 OTHERS 2x4SPFStud BRACING- TOP CHORD Structuralwoodsheathing directly applied or 6-0-0 oc purlins.BOT CHORD Rigidceiling directly applied or 10-0-0 oc bracing. MiTekrecommends that Stabilizers and requiredcross bracing beinstalled during truss erection,in accordancewithStabilizer Installation guide.REACTIONS.All bearings 39-1-14. (lb)-Max Horz1=-94(LC 17) Max UpliftAll uplift 100 lb orless at joint(s) 19, 21, 22, 24, 17, 16, 14 except 23=-102(LC 16), 15=-104(LC17) MaxGravAllreactions 250 lb orless at joint(s) 1, 13 except 19=429(LC 37), 21=384(LC 37), 22=384(LC 38), 23=428(LC 38), 24=394(LC 38), 17=384(LC 37), 16=384(LC 38), 15=428(LC 38), 14=394(LC 38) FORCES.(lb)-Max. Comp./Max.Ten.-All forces 250 (lb) orless exceptwhenshown. WEBS 7-19=-349/127, 6-21=-304/92, 4-22=-304/133, 3-23=-349/152, 2-24=-310/130,8-17=-304/92, 10-16=-304/132, 11-15=-349/154, 12-14=-310/130 NOTES- 1) Unbalancedroofliveloads have been considered for this design. 2)Wind:ASCE 7-10;Vult=115mph(3-second gust)Vasd=91mph;TCDL=6.0psf;BCDL=6.0psf; h=25ft; Cat. II;Exp C; enclosed; MWFRS(envelope) gable end zone and C-CExterior(2) 0-8-12 to 4-7-10,Interior(1) 4-7-10 to 13-7-15,Exterior(2) 13-7-15 to 31-0-4, Interior(1) 31-0-4 to 38-5-2zone;cantileverleft and right exposed ; end verticalleft and right exposed;C-C formembers and forces & MWFRS forreactionsshown; Lumber DOL=1.60 plate grip DOL=1.60 3)TCLL:ASCE 7-10;Pr=20.0 psf(roofliveload: Lumber DOL=1.15Plate DOL=1.15);Pg=20.0 psf(groundsnow);Pf=20.4 psf(flat roofsnow: Lumber DOL=1.15Plate DOL=1.15); CategoryII;Exp C; PartiallyExp.; Ct=1.1, Lu=50-0-0;Min. flatroofsnowload governs. Rainsurcharge applied to all exposedsurfaceswithslopesless than 0.500/12 in accordancewithIBC 1608.3.4. 4) Unbalancedsnowloads have been considered for this design. 5)Provide adequate drainage to preventwater ponding.6)All plates are 1.5x4MT20 unless otherwiseindicated. 7)Gablerequirescontinuous bottomchord bearing. 8)This truss has been designed for a 10.0 psf bottomchordliveload nonconcurrentwith any otherliveloads.9)Providemechanicalconnection(by others) of truss to bearing platecapable of withstanding 100 lb uplift at joint(s) 19, 21, 22, 24, 17, 16, 14 except(jt=lb) 23=102, 15=104. 10)This trussis designedin accordancewith the 2012 InternationalBuilding Code section 2306.1 and referencedstandardANSI/TPI1. LOADCASE(S)Standard DE Job # 59223-W1 Dansco Engineering, LLC Date: 6/13/18 WARNING – VERIFY DESIGN PARAMETERS AND READ NOTES BEFORE FABRICATION AND INSTALLATION!!! This truss design is adequate for the design parameters shown. Review and approval of design parameters is the responsibility of the building designer, not the truss designer or truss engineer. Permanent bracing requirements against out-of-plane buckling are noted/shown for individual truss members (and for the truss as a whole) subjected to gravity and wind loads. Additional permanent bracing design shall be the responsibility of the design professional of record. Temporary and erection bracing shall be the responsibility of the contractor. Reference ANSI/TPI-1, “National Design Standard for Metal Plate Connected Wood Truss Construction” and TPI/WTCA BCSI-06, “Building Component Safety Information Guide to Good Practice for Handling, Installing, Restraining and Bracing of Metal Plate Connected Wood Trusses” for additional information. Job 1802242-12T Truss V18 TrussType GABLE Qty 1 Ply 1 1802242-12TDWHWoodside-West Clay- 4 Job Reference (optional)Run:8.200 s Apr72018 Print:8.200 s Apr72018MiTekIndustries,Inc.Tue Jun1221:13:162018 Page1ID:bRTO9oDnRLEHvJjVgeMKW3yF_s1-SKcwhpFif7Xm57C8mhjdnMcmMhoi0kEn0jMo8Vz6wFH Scale=1:55.7 0 -1 -10 0 -1 -10 T1 T2 T1 B1 ST3ST3 ST2 ST1 ST3 ST2 ST1 B3B21 2 3 4 5 6 7 8 9 18 17 16 15 14 13 12 11 10 19 20 21 22 23 24 25 26 3x4 3x4 3x4 6x6 6x6 3x4 34-4-5 34-4-5 13-3-2 13-3-2 21-1-2 7-10-0 34-4-5 13-3-2 5 -4 -11 5 -6 -5 5 -4 -11 5.0012 LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 10.0 SPACING- PlateGrip DOL Lumber DOL RepStressIncr Code 2-0-0 1.15 1.15 YES IBC2012/TPI2007 CSI. TC BC WB Matrix-SH 0.27 0.16 0.22 DEFL. Vert(LL) Vert(TL) Horz(TL) in n/a n/a 0.00 (loc) - - 9 l/defl n/a n/a n/a L/d 999 999 n/a PLATES MT20 Weight: 107 lb FT= 20% GRIP 197/144 LUMBER- TOP CHORD2x4SPF No.2 BOT CHORD2x4SPF No.2OTHERS2x4SPFStud BRACING- TOP CHORD Structuralwoodsheathing directly applied or 6-0-0 oc purlins. BOT CHORD Rigidceiling directly applied or 10-0-0 oc bracing. MiTekrecommends that Stabilizers and requiredcross bracing beinstalled during truss erection,in accordancewithStabilizer Installation guide. REACTIONS.All bearings 34-4-5.(lb)-Max Horz1=-91(LC 21) Max UpliftAll uplift 100 lb orless at joint(s) 1, 9, 14, 16 except 17=-102(LC 16), 18=-113(LC 16), 11=-101(LC 17), 10=-113(LC 17)MaxGravAllreactions 250 lb orless at joint(s) 1, 9 except 14=463(LC 37), 16=294(LC 2), 17=423(LC 38), 18=500(LC 38), 12=294(LC 2), 11=423(LC 38), 10=500(LC 38) FORCES.(lb)-Max. Comp./Max.Ten.-All forces 250 (lb) orless exceptwhenshown. WEBS 5-14=-383/130, 3-17=-355/154, 2-18=-379/155, 7-11=-355/154, 8-10=-379/155 NOTES- 1) Unbalancedroofliveloads have been considered for this design. 2)Wind:ASCE 7-10;Vult=115mph(3-second gust)Vasd=91mph;TCDL=6.0psf;BCDL=6.0psf; h=25ft; Cat. II;Exp C; enclosed; MWFRS(envelope) gable end zone and C-CExterior(2) 0-8-12 to 4-1-14,Interior(1) 4-1-14 to 13-3-2,Exterior(2) 13-3-2 to 25-11-5, Interior(1) 25-11-5 to 33-7-9zone;cantileverleft and right exposed ; end verticalleft and right exposed;C-C formembers and forces &MWFRS forreactionsshown; Lumber DOL=1.60 plate grip DOL=1.60 3)TCLL:ASCE 7-10;Pr=20.0 psf(roofliveload: Lumber DOL=1.15Plate DOL=1.15);Pg=20.0 psf(groundsnow);Pf=20.4 psf(flat roofsnow: Lumber DOL=1.15Plate DOL=1.15); CategoryII;Exp C; PartiallyExp.; Ct=1.1, Lu=50-0-0;Min. flatroofsnowload governs. Rainsurcharge applied to all exposedsurfaceswithslopesless than 0.500/12 in accordancewithIBC 1608.3.4. 4) Unbalancedsnowloads have been considered for this design. 5)Provide adequate drainage to preventwater ponding. 6)All plates are 1.5x4MT20 unless otherwiseindicated. 7)Gablerequirescontinuous bottomchord bearing.8)This truss has been designed for a 10.0 psf bottomchordliveload nonconcurrentwith any otherliveloads. 9)Providemechanicalconnection(by others) of truss to bearing platecapable of withstanding 100 lb uplift at joint(s) 1, 9, 14, 16 except(jt=lb) 17=102, 18=113, 11=101, 10=113.10)This trussis designedin accordancewith the 2012 InternationalBuilding Code section 2306.1 and referencedstandardANSI/TPI 1. LOADCASE(S)Standard DE Job # 59223-W1 Dansco Engineering, LLC Date: 6/13/18 WARNING – VERIFY DESIGN PARAMETERS AND READ NOTES BEFORE FABRICATION AND INSTALLATION!!! This truss design is adequate for the design parameters shown. Review and approval of design parameters is the responsibility of the building designer, not the truss designer or truss engineer. Permanent bracing requirements against out-of-plane buckling are noted/shown for individual truss members (and for the truss as a whole) subjected to gravity and wind loads. Additional permanent bracing design shall be the responsibility of the design professional of record. Temporary and erection bracing shall be the responsibility of the contractor. Reference ANSI/TPI-1, “National Design Standard for Metal Plate Connected Wood Truss Construction” and TPI/WTCA BCSI-06, “Building Component Safety Information Guide to Good Practice for Handling, Installing, Restraining and Bracing of Metal Plate Connected Wood Trusses” for additional information. Job 1802242-12T Truss V19 TrussType GABLE Qty 1 Ply 1 1802242-12TDWHWoodside-West Clay- 4 Job Reference (optional)Run:8.200 s Apr72018 Print:8.200 s Apr72018MiTekIndustries,Inc.Tue Jun1221:13:182018 Page1ID:bRTO9oDnRLEHvJjVgeMKW3yF_s1-Ojkg6UGyAlnTKRMWt6l5snh2UVRVUft3U1rvCOz6wFF Scale:1/4"=1' 0 -1 -10 0 -1 -10 T1 T2 T1 B1 ST3ST2 ST1 ST2 ST1 B21 2 3 4 5 6 7 8 9 15 14 13 12 11 10 16 17 18 19 20 21 3x5 3x4 3x4 3x5 3x4 29-6-11 29-6-11 12-10-6 12-10-6 16-8-6 3-10-0 29-6-11 12-10-6 5 -2 -11 5 -4 -5 5 -2 -11 5.0012 PlateOffsets(X,Y)-- [4:0-2-0,Edge], [6:0-2-0,Edge] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 10.0 SPACING- PlateGrip DOL Lumber DOL RepStressIncr Code 2-0-0 1.15 1.15 YES IBC2012/TPI2007 CSI. TC BC WB Matrix-SH 0.48 0.33 0.14 DEFL. Vert(LL) Vert(TL) Horz(TL) in n/a n/a 0.01 (loc) - - 9 l/defl n/a n/a n/a L/d 999 999 n/a PLATES MT20 Weight: 88 lb FT= 20% GRIP 197/144 LUMBER- TOP CHORD2x4SPF No.2BOT CHORD2x4SPF No.2 OTHERS 2x4SPFStud BRACING- TOP CHORD Structuralwoodsheathing directly applied or 6-0-0 oc purlins.BOT CHORD Rigidceiling directly applied or 10-0-0 oc bracing. MiTekrecommends that Stabilizers and requiredcross bracing beinstalled during truss erection,in accordancewithStabilizer Installation guide.REACTIONS.All bearings 29-6-11. (lb)-Max Horz1=-88(LC 17) Max UpliftAll uplift 100 lb orless at joint(s) 1, 9, 12, 14, 11 except 15=-153(LC 16), 10=-154(LC 17)MaxGravAllreactions 250 lb orless at joint(s) except 1=296(LC 38), 9=296(LC 38), 12=359(LC 37), 14=286(LC 38), 15=657(LC 38), 11=286(LC 38), 10=657(LC 38) FORCES.(lb)-Max. Comp./Max.Ten.-All forces 250 (lb) orless exceptwhenshown. WEBS 5-12=-269/70, 2-15=-495/201, 8-10=-495/202 NOTES- 1) Unbalancedroofliveloads have been considered for this design. 2)Wind:ASCE 7-10;Vult=115mph(3-second gust)Vasd=91mph;TCDL=6.0psf;BCDL=6.0psf; h=25ft; Cat. II;Exp C; enclosed; MWFRS(envelope) gable end zone and C-CExterior(2) 0-8-12 to 3-8-12,Interior(1) 3-8-12 to 12-10-6,Exterior(2) 12-10-6 to 16-8-6, Interior(1) 20-11-4 to 28-9-15zone;cantileverleft and right exposed ; end verticalleft and right exposed;C-C formembers and forces&MWFRS forreactionsshown; Lumber DOL=1.60 plate grip DOL=1.60 3)TCLL:ASCE 7-10;Pr=20.0 psf(roofliveload: Lumber DOL=1.15Plate DOL=1.15);Pg=20.0 psf(groundsnow);Pf=20.4 psf(flat roofsnow: Lumber DOL=1.15Plate DOL=1.15); CategoryII;Exp C; PartiallyExp.; Ct=1.1, Lu=50-0-0;Min. flatroofsnowload governs. Rainsurcharge applied to all exposedsurfaceswithslopesless than 0.500/12 in accordancewithIBC 1608.3.4. 4) Unbalancedsnowloads have been considered for this design. 5)Provide adequate drainage to preventwater ponding. 6)All plates are 1.5x4MT20 unless otherwiseindicated. 7)Gablerequirescontinuous bottomchord bearing.8)This truss has been designed for a 10.0 psf bottomchordliveload nonconcurrentwith any otherliveloads. 9)Providemechanicalconnection(by others) of truss to bearing platecapable of withstanding 100 lb uplift at joint(s) 1, 9, 12, 14, 11 except(jt=lb) 15=153, 10=154.10)This trussis designedin accordancewith the 2012 InternationalBuilding Code section 2306.1 and referencedstandardANSI/TPI 1. LOADCASE(S)Standard DE Job # 59223-W1 Dansco Engineering, LLC Date: 6/13/18 WARNING – VERIFY DESIGN PARAMETERS AND READ NOTES BEFORE FABRICATION AND INSTALLATION!!! This truss design is adequate for the design parameters shown. Review and approval of design parameters is the responsibility of the building designer, not the truss designer or truss engineer. Permanent bracing requirements against out-of-plane buckling are noted/shown for individual truss members (and for the truss as a whole) subjected to gravity and wind loads. Additional permanent bracing design shall be the responsibility of the design professional of record. Temporary and erection bracing shall be the responsibility of the contractor. Reference ANSI/TPI-1, “National Design Standard for Metal Plate Connected Wood Truss Construction” and TPI/WTCA BCSI-06, “Building Component Safety Information Guide to Good Practice for Handling, Installing, Restraining and Bracing of Metal Plate Connected Wood Trusses” for additional information. Job 1802242-12T Truss V20 TrussType Valley Qty 1 Ply 1 1802242-12TDWHWoodside-West Clay- 4 Job Reference (optional)Run:8.200 s Apr72018 Print:8.200 s Apr72018MiTekIndustries,Inc.Tue Jun1221:13:192018 Page1ID:bRTO9oDnRLEHvJjVgeMKW3yF_s1-svI2KqHax2vKyaxjRpGKP?EIEvrKD7kDjhaSlqz6wFE Scale=1:39.9 T1 T1 B1 ST3 ST2 ST1 ST2 ST1 B21 2 3 4 5 6 7 13 12 11 10 9 8 14 15 16 17 3x4 4x4 3x4 3x4 24-9-2 24-9-2 12-4-9 12-4-9 24-9-2 12-4-9 0 -0 -4 5 -1 -14 0 -0 -4 5.0012 LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 10.0 SPACING- PlateGrip DOL Lumber DOL RepStressIncr Code 2-0-0 1.15 1.15 YES IBC2012/TPI2007 CSI. TC BC WB Matrix-SH 0.16 0.10 0.10 DEFL. Vert(LL) Vert(TL) Horz(TL) in n/a n/a 0.00 (loc) - - 7 l/defl n/a n/a n/a L/d 999 999 n/a PLATES MT20 Weight: 72 lb FT= 20% GRIP 197/144 LUMBER- TOP CHORD2x4SPF No.2 BOT CHORD2x4SPF No.2OTHERS2x4SPFStud BRACING- TOP CHORD Structuralwoodsheathing directly applied or 6-0-0 oc purlins. BOT CHORD Rigidceiling directly applied or 10-0-0 oc bracing. MiTekrecommends that Stabilizers and requiredcross bracing beinstalled during truss erection,in accordancewithStabilizer Installation guide. REACTIONS.All bearings 24-9-2.(lb)-Max Horz1=86(LC 16) Max UpliftAll uplift 100 lb orless at joint(s) 1, 7, 13, 8 except 12=-105(LC 16), 9=-105(LC 17) MaxGravAllreactions 250 lb orless at joint(s) 1, 7 except 11=284(LC 2), 12=335(LC 33), 13=338(LC 2),9=335(LC 34), 8=338(LC 2) FORCES.(lb)-Max. Comp./Max.Ten.-All forces 250 (lb) orless exceptwhenshown.WEBS 3-12=-259/155, 5-9=-259/155 NOTES-1) Unbalancedroofliveloads have been considered for this design. 2)Wind:ASCE 7-10;Vult=115mph(3-second gust)Vasd=91mph;TCDL=6.0psf;BCDL=6.0psf; h=25ft; Cat. II;Exp C; enclosed; MWFRS(envelope) gable end zone and C-CExterior(2) 0-9-1 to 3-9-1,Interior(1) 3-9-1 to 12-4-9,Exterior(2) 12-4-9 to 15-4-9zone; cantileverleft and right exposed ; end verticalleft and right exposed;C-C formembers and forces&MWFRS forreactionsshown; Lumber DOL=1.60 plate grip DOL=1.60 3)TCLL:ASCE 7-10;Pr=20.0 psf(roofliveload: Lumber DOL=1.15Plate DOL=1.15);Pg=20.0 psf(groundsnow);Pf=15.4 psf(flat roofsnow: Lumber DOL=1.15Plate DOL=1.15); CategoryII;Exp C; PartiallyExp.; Ct=1.1 4) Unbalancedsnowloads have been considered for this design. 5)All plates are 1.5x4MT20 unless otherwiseindicated. 6)Gablerequirescontinuous bottomchord bearing. 7)This truss has been designed for a 10.0 psf bottomchordliveload nonconcurrentwith any otherliveloads. 8)Providemechanicalconnection(by others) of truss to bearing platecapable of withstanding 100 lb uplift at joint(s) 1, 7, 13, 8 except (jt=lb) 12=105, 9=105.9)This trussis designedin accordancewith the 2012 InternationalBuilding Code section 2306.1 and referencedstandardANSI/TPI 1. LOADCASE(S)Standard DE Job # 59223-W1 Dansco Engineering, LLC Date: 6/13/18 WARNING – VERIFY DESIGN PARAMETERS AND READ NOTES BEFORE FABRICATION AND INSTALLATION!!! This truss design is adequate for the design parameters shown. Review and approval of design parameters is the responsibility of the building designer, not the truss designer or truss engineer. Permanent bracing requirements against out-of-plane buckling are noted/shown for individual truss members (and for the truss as a whole) subjected to gravity and wind loads. Additional permanent bracing design shall be the responsibility of the design professional of record. Temporary and erection bracing shall be the responsibility of the contractor. Reference ANSI/TPI-1, “National Design Standard for Metal Plate Connected Wood Truss Construction” and TPI/WTCA BCSI-06, “Building Component Safety Information Guide to Good Practice for Handling, Installing, Restraining and Bracing of Metal Plate Connected Wood Trusses” for additional information. Job 1802242-12T Truss V21 TrussType Valley Qty 1 Ply 1 1802242-12TDWHWoodside-West Clay- 4 Job Reference (optional)Run:8.200 s Apr72018 Print:8.200 s Apr72018MiTekIndustries,Inc.Tue Jun1221:13:202018 Page1ID:bRTO9oDnRLEHvJjVgeMKW3yF_s1-K5sQXAICiM1BakWv?WoZxCmRBIAMyaMMxLK0HGz6wFD Scale:3/8"=1' T1 T1 B1 ST2 ST1 ST1 B2 1 2 3 4 5 9 8 7 6 10 11 12 13 14 15 3x4 4x4 3x4 3x4 1.5x41.5x4 1.5x4 1.5x4 1.5x4 0-0-10 0-0-10 19-11-8 19-10-14 9-11-12 9-11-12 19-11-8 9-11-12 0 -0 -4 4 -1 -14 0 -0 -4 5.0012 LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 10.0 SPACING- PlateGrip DOL Lumber DOL RepStressIncr Code 2-0-0 1.15 1.15 YES IBC2012/TPI2007 CSI. TC BC WB Matrix-SH 0.28 0.17 0.08 DEFL. Vert(LL) Vert(TL) Horz(TL) in n/a n/a 0.00 (loc) - - 5 l/defl n/a n/a n/a L/d 999 999 n/a PLATES MT20 Weight: 54 lb FT= 20% GRIP 197/144 LUMBER- TOP CHORD2x4SPF No.2 BOT CHORD2x4SPF No.2OTHERS2x4SPFStud BRACING- TOP CHORD Structuralwoodsheathing directly applied or 6-0-0 oc purlins. BOT CHORD Rigidceiling directly applied or 10-0-0 oc bracing. MiTekrecommends that Stabilizers and requiredcross bracing beinstalled during truss erection,in accordancewithStabilizer Installation guide. REACTIONS.All bearings 19-10-5.(lb)-Max Horz1=68(LC 16) Max UpliftAll uplift 100 lb orless at joint(s) 1, 5 except 9=-140(LC 16), 6=-140(LC 17) MaxGravAllreactions 250 lb orless at joint(s) 1, 5, 7 except 9=459(LC 33), 6=459(LC 34) FORCES.(lb)-Max. Comp./Max.Ten.-All forces 250 (lb) orless exceptwhenshown. WEBS 2-9=-328/186, 4-6=-328/186 NOTES- 1) Unbalancedroofliveloads have been considered for this design.2)Wind:ASCE 7-10;Vult=115mph(3-second gust)Vasd=91mph;TCDL=6.0psf;BCDL=6.0psf; h=25ft; Cat. II;Exp C; enclosed; MWFRS(envelope) gable end zone and C-CExterior(2) 0-9-1 to 3-9-1,Interior(1) 3-9-1 to 9-11-12,Exterior(2) 9-11-12 to 12-11-12 zone;cantileverleft and right exposed ; end verticalleft and right exposed;C-C formembers and forces&MWFRS forreactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3)TCLL:ASCE 7-10;Pr=20.0 psf(roofliveload: Lumber DOL=1.15Plate DOL=1.15);Pg=20.0 psf(groundsnow);Pf=15.4 psf(flat roofsnow: Lumber DOL=1.15Plate DOL=1.15); CategoryII;Exp C; PartiallyExp.; Ct=1.1 4) Unbalancedsnowloads have been considered for this design. 5)Gablerequirescontinuous bottomchord bearing. 6)This truss has been designed for a 10.0 psf bottomchordliveload nonconcurrentwith any otherliveloads. 7)Providemechanicalconnection(by others) of truss to bearing platecapable of withstanding 100 lb uplift at joint(s) 1, 5 except(jt=lb) 9=140, 6=140. 8)This trussis designedin accordancewith the 2012 InternationalBuilding Code section 2306.1 and referencedstandardANSI/TPI 1. LOADCASE(S)Standard DE Job # 59223-W1 Dansco Engineering, LLC Date: 6/13/18 WARNING – VERIFY DESIGN PARAMETERS AND READ NOTES BEFORE FABRICATION AND INSTALLATION!!! This truss design is adequate for the design parameters shown. Review and approval of design parameters is the responsibility of the building designer, not the truss designer or truss engineer. Permanent bracing requirements against out-of-plane buckling are noted/shown for individual truss members (and for the truss as a whole) subjected to gravity and wind loads. Additional permanent bracing design shall be the responsibility of the design professional of record. Temporary and erection bracing shall be the responsibility of the contractor. Reference ANSI/TPI-1, “National Design Standard for Metal Plate Connected Wood Truss Construction” and TPI/WTCA BCSI-06, “Building Component Safety Information Guide to Good Practice for Handling, Installing, Restraining and Bracing of Metal Plate Connected Wood Trusses” for additional information. Job 1802242-12T Truss V22 TrussType Valley Qty 1 Ply 1 1802242-12TDWHWoodside-West Clay- 4 Job Reference (optional)Run:8.200 s Apr72018 Print:8.200 s Apr72018MiTekIndustries,Inc.Tue Jun1221:13:202018 Page1ID:bRTO9oDnRLEHvJjVgeMKW3yF_s1-K5sQXAICiM1BakWv?WoZxCmTBIBaybkMxLK0HGz6wFD Scale=1:24.4 T1 T1 B2 ST2 ST1 ST1 B1 1 2 3 4 5 9 8 7 6 10 11 12 13 3x4 4x4 3x43x41.5x41.5x4 1.5x4 1.5x4 1.5x4 15-1-14 15-1-14 7-6-15 7-6-15 15-1-14 7-6-15 0 -0 -4 3 -1 -14 0 -0 -4 5.0012 LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 10.0 SPACING- PlateGrip DOL Lumber DOL RepStressIncr Code 2-0-0 1.15 1.15 YES IBC2012/TPI2007 CSI. TC BC WB Matrix-SH 0.15 0.10 0.05 DEFL. Vert(LL) Vert(TL) Horz(TL) in n/a n/a 0.00 (loc) - - 5 l/defl n/a n/a n/a L/d 999 999 n/a PLATES MT20 Weight: 39 lb FT= 20% GRIP 197/144 LUMBER- TOP CHORD2x4SPF No.2 BOT CHORD2x4SPF No.2OTHERS2x4SPFStud BRACING- TOP CHORD Structuralwoodsheathing directly applied or 6-0-0 oc purlins. BOT CHORD Rigidceiling directly applied or 10-0-0 oc bracing. MiTekrecommends that Stabilizers and requiredcross bracing beinstalled during truss erection,in accordancewithStabilizer Installation guide. REACTIONS.All bearings 15-1-14.(lb)-Max Horz1=-50(LC 21) Max UpliftAll uplift 100 lb orless at joint(s) 1, 5 except 9=-104(LC 16), 6=-103(LC 17) MaxGravAllreactions 250 lb orless at joint(s) 1, 5 except 8=287(LC 2), 9=325(LC 33), 6=325(LC 34) FORCES.(lb)-Max. Comp./Max.Ten.-All forces 250 (lb) orless exceptwhenshown. NOTES- 1) Unbalancedroofliveloads have been considered for this design. 2)Wind:ASCE 7-10;Vult=115mph(3-second gust)Vasd=91mph;TCDL=6.0psf;BCDL=6.0psf; h=25ft; Cat. II;Exp C; enclosed;MWFRS(envelope) gable end zone and C-CExterior(2) 0-9-1 to 3-6-15,Interior(1) 3-6-15 to 7-6-15,Exterior(2) 7-6-15 to 10-6-15 zone;cantileverleft and right exposed ; end verticalleft and right exposed;C-C formembers and forces&MWFRS forreactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3)TCLL:ASCE 7-10;Pr=20.0 psf(roofliveload: Lumber DOL=1.15Plate DOL=1.15);Pg=20.0 psf(groundsnow);Pf=15.4 psf(flat roofsnow: Lumber DOL=1.15Plate DOL=1.15); CategoryII;Exp C; PartiallyExp.; Ct=1.1 4) Unbalancedsnowloads have been considered for this design. 5)Gablerequirescontinuous bottomchord bearing. 6)This truss has been designed for a 10.0 psf bottomchordliveload nonconcurrentwith any otherliveloads. 7)Providemechanicalconnection(by others) of truss to bearing platecapable of withstanding 100 lb uplift at joint(s) 1, 5 except(jt=lb) 9=104, 6=103. 8)This trussis designedin accordancewith the 2012 InternationalBuilding Code section 2306.1 and referencedstandardANSI/TPI 1. LOADCASE(S)Standard DE Job # 59223-W1 Dansco Engineering, LLC Date: 6/13/18 WARNING – VERIFY DESIGN PARAMETERS AND READ NOTES BEFORE FABRICATION AND INSTALLATION!!! This truss design is adequate for the design parameters shown. Review and approval of design parameters is the responsibility of the building designer, not the truss designer or truss engineer. Permanent bracing requirements against out-of-plane buckling are noted/shown for individual truss members (and for the truss as a whole) subjected to gravity and wind loads. Additional permanent bracing design shall be the responsibility of the design professional of record. Temporary and erection bracing shall be the responsibility of the contractor. Reference ANSI/TPI-1, “National Design Standard for Metal Plate Connected Wood Truss Construction” and TPI/WTCA BCSI-06, “Building Component Safety Information Guide to Good Practice for Handling, Installing, Restraining and Bracing of Metal Plate Connected Wood Trusses” for additional information. Job 1802242-12T Truss V23 TrussType Valley Qty 1 Ply 1 1802242-12TDWHWoodside-West Clay- 4 Job Reference (optional)Run:8.200 s Apr72018 Print:8.200 s Apr72018MiTekIndustries,Inc.Tue Jun1221:13:212018 Page1ID:bRTO9oDnRLEHvJjVgeMKW3yF_s1-oIPplWIrTg92Bu55YEJoUQJcIiVkh2yWA?3Zpjz6wFC Scale=1:16.7 T1 T1 B1 ST1 1 2 3 4 5 6 7 8 9 10 2x4 4x4 2x41.5x4 10-4-5 10-4-5 5-2-2 5-2-2 10-4-5 5-2-2 0 -0 -4 2 -1 -14 0 -0 -4 5.0012 LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 10.0 SPACING- PlateGrip DOL Lumber DOL RepStressIncr Code 2-0-0 1.15 1.15 YES IBC2012/TPI2007 CSI. TC BC WB Matrix-P 0.32 0.17 0.06 DEFL. Vert(LL) Vert(TL) Horz(TL) in n/a n/a 0.00 (loc) - - 3 l/defl n/a n/a n/a L/d 999 999 n/a PLATES MT20 Weight: 24 lb FT= 20% GRIP 197/144 LUMBER- TOP CHORD2x4SPF No.2 BOT CHORD2x4SPF No.2OTHERS2x4SPFStud BRACING- TOP CHORD Structuralwoodsheathing directly applied or 6-0-0 oc purlins. BOT CHORD Rigidceiling directly applied or 10-0-0 oc bracing. MiTekrecommends that Stabilizers and requiredcross bracing beinstalled during truss erection,in accordancewithStabilizer Installation guide. REACTIONS.(lb/size)1=153/10-4-5(min. 0-1-8), 3=153/10-4-5(min. 0-1-8), 4=320/10-4-5(min. 0-1-8)Max Horz1=33(LC 16) Max Uplift1=-46(LC 16), 3=-51(LC 17), 4=-11(LC 16) MaxGrav1=175(LC 2), 3=175(LC 2), 4=357(LC 2) FORCES.(lb)-Max. Comp./Max.Ten.-All forces 250 (lb) orless exceptwhenshown. NOTES- 1) Unbalancedroofliveloads have been considered for this design. 2)Wind:ASCE 7-10;Vult=115mph(3-second gust)Vasd=91mph;TCDL=6.0psf;BCDL=6.0psf; h=25ft; Cat. II;Exp C; enclosed;MWFRS(envelope) gable end zone and C-CExterior(2) 0-9-1 to 3-9-1,Interior(1) 3-9-1 to 5-2-2,Exterior(2) 5-2-2 to 8-2-2zone; cantileverleft and right exposed ; end verticalleft and right exposed;C-C formembers and forces&MWFRS forreactionsshown; Lumber DOL=1.60 plate grip DOL=1.60 3)TCLL:ASCE 7-10;Pr=20.0 psf(roofliveload: Lumber DOL=1.15Plate DOL=1.15);Pg=20.0 psf(groundsnow);Pf=15.4 psf(flat roofsnow: Lumber DOL=1.15Plate DOL=1.15); CategoryII;Exp C; PartiallyExp.; Ct=1.1 4) Unbalancedsnowloads have been considered for this design. 5)Gablerequirescontinuous bottomchord bearing. 6)This truss has been designed for a 10.0 psf bottomchordliveload nonconcurrentwith any otherliveloads. 7)Providemechanicalconnection(by others) of truss to bearing platecapable of withstanding 100 lb uplift at joint(s) 1, 3, 4. 8)This trussis designedin accordancewith the 2012 InternationalBuilding Code section 2306.1 and referencedstandardANSI/TPI 1. LOADCASE(S)Standard DE Job # 59223-W1 Dansco Engineering, LLC Date: 6/13/18 WARNING – VERIFY DESIGN PARAMETERS AND READ NOTES BEFORE FABRICATION AND INSTALLATION!!! This truss design is adequate for the design parameters shown. Review and approval of design parameters is the responsibility of the building designer, not the truss designer or truss engineer. Permanent bracing requirements against out-of-plane buckling are noted/shown for individual truss members (and for the truss as a whole) subjected to gravity and wind loads. Additional permanent bracing design shall be the responsibility of the design professional of record. Temporary and erection bracing shall be the responsibility of the contractor. Reference ANSI/TPI-1, “National Design Standard for Metal Plate Connected Wood Truss Construction” and TPI/WTCA BCSI-06, “Building Component Safety Information Guide to Good Practice for Handling, Installing, Restraining and Bracing of Metal Plate Connected Wood Trusses” for additional information. Job 1802242-12T Truss V24 TrussType Valley Qty 1 Ply 1 1802242-12TDWHWoodside-West Clay- 4 Job Reference (optional)Run:8.200 s Apr72018 Print:8.200 s Apr72018MiTekIndustries,Inc.Tue Jun1221:13:222018 Page1ID:bRTO9oDnRLEHvJjVgeMKW3yF_s1-GUzBysJTEzHvp2fI6xq10dsr16rpQV4fPfp7M9z6wFB Scale=1:10.5 T1 T1 B1 1 2 3 2x4 3x4 2x4 5-6-11 5-6-11 2-9-6 2-9-6 5-6-11 2-9-6 0 -0 -4 1 -1 -14 0 -0 -4 5.0012 PlateOffsets(X,Y)-- [2:0-2-0,Edge] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 10.0 SPACING- PlateGrip DOL Lumber DOL RepStressIncr Code 2-0-0 1.15 1.15 YES IBC2012/TPI2007 CSI. TC BC WB Matrix-P 0.06 0.18 0.00 DEFL. Vert(LL) Vert(TL) Horz(TL) in n/a n/a 0.00 (loc) - - 3 l/defl n/a n/a n/a L/d 999 999 n/a PLATES MT20 Weight: 11 lb FT= 20% GRIP 197/144 LUMBER- TOP CHORD2x4SPF No.2BOT CHORD2x4SPF No.2 BRACING- TOP CHORD Structuralwoodsheathing directly applied or 5-6-11 oc purlins.BOT CHORD Rigidceiling directly applied or 10-0-0 oc bracing. MiTekrecommends that Stabilizers and requiredcross bracing beinstalled during truss erection,in accordancewithStabilizer Installation guide.REACTIONS.(lb/size)1=143/5-6-11(min. 0-1-8), 3=143/5-6-11(min. 0-1-8) Max Horz1=-15(LC 17) Max Uplift1=-24(LC 16), 3=-24(LC 17)MaxGrav1=162(LC 2), 3=162(LC 2) FORCES.(lb)-Max. Comp./Max.Ten.-All forces 250 (lb) orless exceptwhenshown. NOTES- 1) Unbalancedroofliveloads have been considered for this design.2)Wind:ASCE 7-10;Vult=115mph(3-second gust)Vasd=91mph;TCDL=6.0psf;BCDL=6.0psf; h=25ft; Cat. II;Exp C; enclosed; MWFRS(envelope) gable end zone and C-CExterior(2)zone;cantileverleft and right exposed ; end verticalleft and right exposed;C-C formembers and forces&MWFRS forreactionsshown; Lumber DOL=1.60 plate grip DOL=1.60 3)TCLL:ASCE 7-10;Pr=20.0 psf(roofliveload: Lumber DOL=1.15Plate DOL=1.15);Pg=20.0 psf(groundsnow);Pf=15.4 psf(flat roofsnow: Lumber DOL=1.15Plate DOL=1.15); CategoryII;Exp C; PartiallyExp.; Ct=1.1 4) Unbalancedsnowloads have been considered for this design. 5)Gablerequirescontinuous bottomchord bearing. 6)This truss has been designed for a 10.0 psf bottomchordliveload nonconcurrentwith any otherliveloads. 7)Providemechanicalconnection(by others) of truss to bearing platecapable of withstanding 100 lb uplift at joint(s) 1, 3. 8)This trussis designedin accordancewith the 2012 InternationalBuilding Code section 2306.1 and referencedstandardANSI/TPI 1. LOADCASE(S)Standard