Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
10
D C I A cV IIS 1 1 2 2 3 ABBREVIATIONS AND TERMS LINE SYMBOLS _ 0 DIAMETER, PHASE ET EXPANSION TANK OAT OUTSIDE AIR TEMPERATURE CF) T DEGREES FAHRENHEIT EW EMERGENCY EYEWASH OBD OD OPPOSED BLADE DAMPER OUTSIDE DIAMETER, OVERFLOW DRAIN A/C AIR CONDITIONING EWC EWT ELECTRIC WATER COOLER ENTERING WATER TEMPERATURE ('F) OF/CI OWNER FURNISHED/CONTRACTOR INSTALLED ACC ACCU AIR COOLED CONDENSER AIR COOLED CONDENSING UNIT EXH EXHAUST OSD OPEN SITE DRAIN AD AREA DRAIN, ACCESS DOOR EXIST EXISTING OZ P OUNCE PUMP AFF AFMS ABOVE FINISHED FLOOR AIR FLOW MEASURING STATION F F&T FURNACE FLOAT AND THERMOSTATIC STEAM TRAP PBD PARALLEL BLADE DAMPER AGA AMERICAN GAS ASSOCIATION FCO FLOOR CLEANOUT PC PD PLUMBING CONTRACTOR PRESSURE DROP AHU AL AIR HANDLING UNIT ACOUSTICALLY LINED, ALUMINUM FCU FD FAN COIL UNIT FLOOR DRAIN, FIRE DAMPER PE PNEUMATIC ELECTRIC AMB AMBIENT FDC FIRE DEPARTMENT CONNECTION PH PIV PHASE POST INDICATOR VALVE ANSI AMERICAN NATIONAL STANDARDS INSTITUTE FDTN FOUNDATION PPM PARTS PER MIWON AO AP ANALOG OUTPUT ACID PROOF, ACCESS PANEL FE FHC FIRE EXTINGUISHER FIRE HOSE CABINET PRV PRESSURE REDUCING VALVE APD AIR PRESSURE DROP (IN. WC.) FLR FLOOR PSI POUNDS PER SQUARE INCH ARCH ARCHITECT FM FACTORY MUTUAL PSIA PSIG POUNDS PER SQUARE INCH ABSOLUTE POUNDS PER SQUARE INCH GAUGE ARI AIR CONDITIONING AND REFRIGERATION INSTITUTE FOV FUEL OIL VENT PTAC PACKAGED TERMINAL AIR CONDITIONER ARV AIR RELIEF VALVE FPM FPVAV FEET PER MINUTE FAN POWERED VAV UNIT PVC POLYVINYL CHLORIDE AS ASHRAE AIR SEPARATOR AMERICAN SOCIETY OF HEATING, REFRIGERATING FS FLOOR SINK R REGISTER REFRIGERANT (12, 22, ETC.) REFRIGERANT LIQUID AND AIR CONDITIONING ENGINEERS FSC FIRE SUPPRESSION CONTRACTOR R12 REFRIGERANT HOT GAS ASME AMERICAN SOCIETY OF MECHANICAL ENGINEERS FSD COMBINATION FIRE/SMOKE DAMPER RA RETURN AIR ASPE AMERICAN SOCIETY OF PLUMBING ENGINEERS FT FOOT, FEET RADN RAT RADIATION RETURN AIR TEMPERATURE ('F) ASTM AMERICAN SOCIETY FOR TESTING AND MATERIALS FTG FTR FOOTING FINNED TUBE RADIATION RCP REINFORCED CONCRETE PIPE ATM AUTO ATMOSPHERE AUTOMATIC G NATURAL GAS RD ROOF DRAIN AVG AVERAGE GA GAGE OR GAUGE REV REVOLUTIONS AVS ACID VENT STACK GAL GALLON RF RG RETURN FAN RETURN GRILLE AW ANNA ACID WASTE AMERICAN WATER WORKS ASSOCIATION GC GIV GENERAL CONTRACTOR GRAVITY INTAKE VENTILATOR RH RELATIVE HUMIDITY, RODDING HOLE BD BUTTERFLY DAMPER GPD GALLONS PER DAY RM RP ROOM RADIANT PANEL BOO BACKDRAFT DAMPER GPH GPM GALLONS PER HOUR GALLONS PER MINUTE RPM REVOLUTIONS PER MINUTE BE BF BOTTOM ELEVATION BARRIER FREE GR GRILLE, GRAINS RPS REVOLUTIONS PER SECOND BFC BELOW FINISHED CEILING GRV GRAVITY RELIEF VENTILATOR RTU RV ROOF TOP UNIT RELIEF VALVE, ROOF VENT BHP BRAKE HORSEPOWER GT GREASE TRAP SA SUPPLY AIR BLDG BUILDING HB HD HOSE BIBB HEAD (FT.) SAN SANITARY BOD BOTTOM OF DUCT Hg MERCURY SO SUPPLY DIFFUSER, SMOKE DAMPER BOP BSMT BOTTOM OF PIPING BASEMENT HHWP HEATING HOT WATER PUMP SEER SEASONAL ENERGY EFFICIENCY RATIO BT BATHTUB HO HUB OUTLET SF SQUARE FOOT, SUPPLY FAN, SAFETY FACTOR BTM BOTTOM HORIZ HORIZONTAL SG SUPPLY GRILLE BtuH BRITISH THERMAL UNIT PER HOUR HP HORSEPOWER, HEAT PUMP SH SHOWER CA CAV COMPRESSED AIR CONSTANT AIR VOLUME HR HRTU HOUR(S) HEATING ONLY ROOFTOP UNIT SK SMACNA SINK SHEET METAL AND AIR CONDITIONING CB CATCH BASIN HX HEAT EXCHANGER POST INDICATOR VALVE CONTRACTORS NATIONAL ASSOCIATION CCW COUNTERCLOCKWISE Hz HERTZ SP STATIC PRESSURE CD CONDENSATE DRAIN IB INVERTED BUCKET STEAM TRAP SPEC SPECIFICATION CO, CARBON DIOXIDE ID INSIDE DIAMETER SQ SR SQUARE SUPPLY REGISTER CF CEILING FAN IE IN INVERT ELEVATION INCH, INCHES SRV SAFETY REUEF VALVE CFM CUBIC FEET PER MINUTE INT INTERIOR SS SERVICE SINK, STAINLESS STEEL CH CHWP CHILLER CHILLED WATER PUMP INV INVERT STD STANDARD CI CAST IRON IPS INTERNATIONAL PIPE STANDARD SV TCC STEAM VENT TEMPERATURE CONTROL CONTRACTOR CMP CORRUGATED METAL PIPE IW K INDIRECT WASTE KELVIN TCP TEMPERATURE CONTROL PANEL CO COMPR CLEANOUT COMPRESSOR KEC KITCHEN EQUIPMENT CONTRACTOR TO TEMPERATURE DIFFERENCE COND CONDENSER kW KILOWATT TE TEMP TOP ELEVATION TEMPERATURE CONY CONVECTOR LAB LAT LABORATORY LEAVING AIR TEMPERATURE ('F) TF TRANSFER FAN CP CPVC CONDENSATE PUMP CHLORINATED POLYVINYL CHLORIDE LAV LAVATORY TG TMV TRANSFER GRILLE THERMOSTATIC MIXING VALVE CT CU COOLING TOWER CONDENSING UNIT LBS LD POUNDS LINEAR DIFFUSER TONS TONS OF REFRIGERATION CUH CABINET UNIT HEATER LP LIQUID PETROLEUM TP TRAP PRIMER CW CLASSROOM UNIT VENTILATOR LTG LIGHTING LEAVING WATER TEMPERATURE CF) TRANS TS TRANSITION TAMPER SWITCH CV CONTROL VALVE LWT THERMOSTAT WITH ASSOCIATED TSP TOTAL STATIC PRESSURE (IN. WC.) CW CLOCKWISE MA MAT MIXED AIR MIXED AIR TEMPERATURE ('F) TXV THERMAL EXPANSION VALVE CWP CONDENSER WATER PUMP MAX MAXIMUM TYP TYPICAL dB DB DECIBEL DRY BULB MB MOP BASIN UCD UNDERCUT DOOR DF DRINKING FOUNTAIN MBH THOUSAND Btu PER HOUR UH UL UNIT HEATER UNDERWRITERS LABORATORIES DG DOOR GRILLE MC MCA MECHANICAL CONTRACTOR MINIMUM CIRCUIT AMPS LION UNLESS OTHERWISE NOTED DH DI DUCT HEATER DIGITAL INPUT MCC MOTOR CONTROL CENTER UR URINAL DIA DIAMETER MD MOTORIZED DAMPER US W UP STREAM UNIT VENTILATOR DIFF DIFFUSER MFR MANUFACTURER V VOLTS, VENT ON DO DOWN DIGITAL OUTPUT MH MIN MANHOLE MINIMUM VAC VACUUM DS DOWNSPOUT, DOWN STREAM MISC MISCELLANEOUS VAV VARIABLE AIR VOLUME DW DISTILLED WATER MS MOP SINK VB VD VACUUM BREAKER VOLUME DAMPER DWG DWH DRAWING DOMESTIC WATER HEATER MTD MV MOUNTED MANUAL VENT VEL VELOCITY DWV DRAIN, WASTE & VENT N NITROGEN VERT VF VERTICAL VENTILATION FAN DX DIRECT EXPANSION NA NC NOT APPUCABLE NOISE CRITERIA, NORMALLY CLOSED VFD VARIABLE FREQUENCY DRIVE EA EAT EXHAUST AIR ENTERING AIR TEMPERATURE ('F) NEC NATIONAL ELECTRIC CODE VTR VENT THROUGH ROOF EC ELECTRICAL CONTRACTOR NFC NATIONAL FIRE CODE VW VERTICAL UNIT VENTILATOR ECO EXTERIOR CLEANOUT NFPA NATIONAL FIRE PROTECTION ASSOCIATION W WASTE, WATT EDR EQUIVALENT DIRECT RADIATION NFWH NON -FREEZE WALL HYDRANT WC WATER COLUMN EER ENERGY EFFICIENCY RATIO NIC NO NOT IN CONTRACT NORMALLY OPEN, NITROUS OXIDE WB WC WET BULB WATER CLOSET EF EFF EXHAUST FAN EFFICIENCY NOM NOMINAL WCO WALL CLEANOUT EG EXHAUST GRILLE NPW NON -POTABLE WATER WH WPO WALL HYDRANT WATER PRESSURE DROP (FT. HD.) EL ELEVATION NTS 0 NOT TO SCALE OXYGEN WSHP WATER SOURCE HEAT PUMP EOM ES END OF MAIN DRIP EMERGENCY SHOWER OA OUTSIDE AIR YO YARD DRAIN ESP EXTERNAL STATIC PRESSURE (IN. WG.) OAI OUTSIDE AIR INTAKE 2 3 PIPING LINE SYMBOLS ► L-0. FLOW HIGH PRESSURE STEAM (>61 PSIG) — HPS O O PIPE STORM DRAIN ST MEDIUM PRESSURE STEAM (16-60 PSIG) — MPS DESIGNATION IN INCHES FOOTING/FOUNDATION DRAIN — — FD — — LOW PRESSURE STEAM (<15 PSIG) ---- LPS CONTINUES (REFERENCE ELSEWHERE) SANITARY WASTE (W) — PIPE HIGH PRESSURE CONDENSATE — — HPC — — SANITARY GREASE SG MEDIUM PRESSURE CONDENSATE — — MPC — — SANITARY FORCED MAIN FM LOW P.,ESSURE CONDENSATE — — LPC — — SANITARY VENT (V) DI �I BOILER BLOW DOWN BBD 111 IIIA ACID WASTE AW BOILER FEED BF REFERENCE SHEET LOCATION FOR ADDITIONAL ACID VENT — — AV PUMPED CONDENSATE PC GLOBE VALVE DRAIN D VACUUM PUMP DISCHARGE VPD If71 INDIRECT WASTE IW HUMIDIFICATION H EQUIPMENT INDICATOR: PUMP DISCHARGE PD MAKE UP WATER MU REDUCED PRESSURE BACKFLOW PREVENTER DOMESTIC COLD WATER (CW) D4 i�H�F-04 AIR RELIEF VENT — — ARV — — DOMESTIC HOT WATER SUPPLY (HWS) -' TRANSFER AIR DUCTWORK ANGLE VALVE TRANSFER AIR DUCTWORK DOMESTIC HOT WATER RETURN (HWR) --- --- HEAT RECLAIM PIPING HR VALVE WITH OUTSIDE STEM & YOKE DROP D44 HEATING WATER SUPPLY HWS RECTANGULAR EXHAUST AIR,� 140'F HOT WATER —'—' -1407 HEATING WATER RETURN HWR L4 I 140F HOT WATER RETURN ---'-140'F ELECTRIC THREE-WAY CONTROL VALVE REFRIGERANT DISCHARGE RD SOLENOID VALVE NON -POTABLE WATER NPW - REFRIGERANT SUCTION RS DRINKING WATER SUPPLY --- DWS --- REFRIGERANT LIQUID RL AQUASTAT DRINKING WATER RETURN --- DWR REFRIGERANT HOT GAS RHG R SOFT WATER SW BRINE SUPPLY BS ALUMINUM, STAINLESS STEEL CHLORINATED WATER CL BRINE RETURN BR I DISTILLED WATER DI CONDENSER WATER SUPPLY CS AUTOMATIC FLOW CONTROL VALVE DEIONIZED WATER DE CONDENSER WATER RETURN CR FIRE SUPPRESSION F CHILLED WATER SUPPLY CWS NATURAL GAS (WC OR PSIG) G CHILLED WATER RETURN CWR Q GAS VENT — _GV_ DUAL TEMPERATURE SUPPLY DTS VACUUM BREAKER LIQUID PETROLEUM LLP DUAL TEMPERATURE RETURN DTR I MEDICAL COMPRESSED AIR (WC OR PSIG) MA HEAT PUMP WATER SUPPLY HPWS DUCTWORK CAP MEDICAL VACUUM My HEAT PUMP WATER RETURN HPWR ®Far OXYGEN 0 GLYCOL HEATING SUPPLY GHS REFRIGERATION SIGHT GLASS NITROGEN N GLYCOL HEATING RETURN GHR I NITROUS OXIDE NO FUEL OIL SUPPLY FOS ACCESS DOOR CARBON DIOXIDE CO, FUEL OIL RETURN FOR ® WET VACUUM CLEANING WVC FUEL OIL VENT FOV WATER HAMMER ARRESTER WITH SCHEDULE TYPE DRY VACUUM CLEANING --- DVC CONDENSATE DRAIN CD COMPRESSED AIR (WC OR PSIG) A CONTROL WIRING • — • — TEMPERED WATER SUPPLY TWS STATIC PRESSURE CHANGE IN O FCO TEMPERED WATER RETURN TWR 2 3 PIPING IDENTITY SYMBOLS REFERENCE SECTION LOCATION THROUGH AN AREA FOR ► L-0. FLOW DIRECTION ARROW, PITCH DIRECTION ARROW ROUND SPIRAL DUCTWORK O O PIPE RISE 24/12 0 PIPE DROP DESIGNATION IN INCHES PIPE CAP RELATES TO ITEM S PIPE CONTINUES (REFERENCE ELSEWHERE) M-401 — PIPE GUIDE DETAIL INDICATOR: X PIPE ANCHOR ROUND SPIRAL SUPPLY AIR, OUTSIDE AIR DUCTWORK RISE ® FLEXIBLE CONNECTOR INDICATOR: © EXPANSION COMPENSATOR DRAWING MODULE LOCATION LOWER LEFT OF MULTIPLE MODULES) H EXPANSION LOOP DRECTANGULAR DI �I CONCENTRIC, ECCENTRIC FITTINGS ROUND SPIRAL SUPPLY AIR, OUTSIDE AIR DUCTWORK DROP 111 IIIA UNION, FLANGED UNION AT SUBSET SHEET SUBSET SHEET D4 GATE VALVE REFERENCE SHEET LOCATION FOR ADDITIONAL I I BALL VALVE Doo GLOBE VALVE ROUND SPIRAL RETURN AIR, 1I' BUTTERFLY VALVE If71 PLUG VALVE TRANSFER AIR DUCTWORK T-pI CHECK VALVE EQUIPMENT INDICATOR: 101 PRESSURE REDUCING VALVE RISE 4 REDUCED PRESSURE BACKFLOW PREVENTER REGISTER INDICATOR: D4 i�H�F-04 DOUBLE CHECK BACKFLOW PREVENTER ROUND SPIRAL RETURN AIR, CHARACTER RELATESTO Z DOUBLE DETECTOR CHECK VALVE ASSEMBLY ASSOCIATED AIR HANDLER (OPTIONAL) TRANSFER AIR DUCTWORK ANGLE VALVE TRANSFER AIR DUCTWORK Q RELIEF VALVE DROP VALVE WITH OUTSIDE STEM & YOKE DROP D44 PNEUMATIC TWO-WAY CONTROL VALVE RECTANGULAR EXHAUST AIR,� PNEUMATIC THREE-WAY CONTROL VALVE ROUND SPIRAL EXHAUST AIR, p� ELECTRIC TWO-WAY CONTROL VALVE L4 I RELIEF AIR DUCTWORK RISE ELECTRIC THREE-WAY CONTROL VALVE RELIEF AIR DUCTWORK RISE SOLENOID VALVE RECTANGULAR EXHAUST AIR, FLOW SWITCH ROUND SPIRAL EXHAUST AIR, RELIEF AIR DUCTWORK DROP PRESSURE SWITCH RELIEF AIR DUCTWORK DROP AQUASTAT LI ORIFICE FLOW METER R DUCTWORK RISE IN DIRECTION T� VENTURI FLOW METER AL SS ALUMINUM, STAINLESS STEEL ® TURBINE FLOW METER I CALIBRATED BALANCE VALVE AIROUTSIDE AIR IN , 1�Z1 AUTOMATIC FLOW CONTROL VALVE TRANSITION IN DIRECTION OF STRAINER DIRECTION OF FLOW STRAINER WITH CAPPED BLOWDOWN MANUAL AIR VENT Q AUTOMATIC AIR VENT RECTANGULAR TO ROUND, Ir VACUUM BREAKER CONCENTRIC DUCT TRANSITION Y TEMPERATURE/PRESSURE TAP I VOLUME DAMPER SAD] AD— THERMOMETER DUCTWORK CAP I PRESSURE GAUGE I I FIRE DAMPER WITH ACCESS DOOR ®Far STEAM TRAP WITH DESIGNATION ACCESS DOOR ® REFRIGERATION SIGHT GLASS O AIR FILTER/DRYER I AIRFLOW MEASURING STATION DOOR ® REFRIGERATION THERMAL EXPANSION VALVE ACCESS DOOR ® INLINE PUMP ® DIFFERENTIAL PRESSURE TRANSMITTER I TEMPERATURE SENSOR WITHI ACCESS DOOR y WHA- A WATER HAMMER ARRESTER WITH SCHEDULE TYPE ACCESS DOOR 30 a P -TRAP AND RISER ® 2*FDs FLOOR DRAIN WITH SIZE & SCHEDULE TYPE 11.90- END OF PIPE CLEANOUT STATIC PRESSURE CHANGE IN O FCO FLOOR CLEANOUT — — — WALL DUCTWORK, DESIGNATION T WCO WALL CLEANOUT CONNECTION Em EXTERIOR CLEANOUT OR RODDING HOLE wV-1 THERMOSTATIC MIXING VALVE WITH SCHEDULE TYPE RADIUS DUCTWORK ELBOW (CENTERLINE RADIUS 1.50) -+ HR -1 - E WH -1 HOSE BIBB, WALL HYDRANT WITH SCHEDULE TYPE IQ I WATER METER Ia I GAS METER 4 OFD ROOF DRAIN, OVERFLOW DRAIN WITH SIZE RADIUS DUCTWORK ELBOW WITH TURNING VANES ItT POST INDICATOR VALVE RECTANGULAR DUCTWORK FIRE DEPARTMENT CONNECTION VALVE TAMPER SWITCH O UPRIGHT SPRINKLER HEAD WYE RADIUS DUCTWORK ELBOW G PENDANT SPRINKLER HEAD • DRY PENDANT SPRINKLER HEAD CONCEALED SPRINKLER HEAD 0 SIDEWALL SPRINKLER HEAD 45' RADIUS DUCTWORK ELBOWC� RADIUS 1.5xW) 3 4 HVAC IDENTITY SYMBOLS REFERENCE SECTION LOCATION THROUGH AN AREA FOR RECTANGULAR DUCTWORK SHEET KEYNOTE LOCATION FOR ADDITIONAL ROUND SPIRAL DUCTWORK 24/12e FLAT OVAL DUCTWORK DIIN INCHES, FIRST 24/12 DESIGNATION IN INCHES, FIRST 240 DESIGNATION IN INCHES NUMERIC CHARACTER DIMENSION I S SIDE SHOWN RELATES TO ITEM DIMENSION IS SIDE SHOWN POINT LEADER '; 1 1 1 AREA LEADER M-401 SECTION LOCATION AT SUBSET SHEET LINE LEADER DETAIL INDICATOR: RECTANGULAR SUPPLY AIR, DRAWING BLOCK TITLE ROUND SPIRAL SUPPLY AIR, OUTSIDE AIR DUCTWORK RISE EQUIPMENT, PIPING OR MATERIALS. FLAT OVAL SUPPLY AIR, OUTSIDE AIR DUCTWORK RISE INDICATOR: OUTSIDE AIR DUCTWORK RISE LARGE SCALE VIEW LOCATION DETAIL LOCATION IN MODULE DRAWING MODULE LOCATION LOWER LEFT OF MULTIPLE MODULES) IN DRAWING MODULE DRAWING (IDENTIFYING DRECTANGULAR SUPPLY AIR, Al M-401 M-501 ROUND SPIRAL SUPPLY AIR, OUTSIDE AIR DUCTWORK DROP ►�Q FLAT OVAL SUPPLY AIR, OUTSIDE AIR DUCTWORK DROP AT SUBSET SHEET SUBSET SHEET OUTSIDE AIR DUCTWORK DROP MATCH LINE INDICATOR: REFERENCE SHEET LOCATION FOR ADDITIONAL REVISION INDICATOR: REFERENCE TITLE BLOCK LOCATION FOR ADDITIONAL RECTANGULAR RETURN AIR, ��Q ROUND SPIRAL RETURN AIR, FLOOR PLAN OVERLAP BEYOND AREA EXTENSION SEE M-102 FLAT OVAL RETURN AIR, TRANSFER AIR DUCTWORK TRANSFER AIR DUCTWORK �CLL_J TRANSFER AIR DUCTWORK 'C1__� RISE EQUIPMENT INDICATOR: RISE DIFFUSER, GRILLE, RISE INFORMATION. REGISTER INDICATOR: RECTANGULAR RETURN AIR, TU-XL� NUMERIC CHARACTER RELATES TO ITEM ALPHANUMERIC CHARACTER RELATES TO BUILDING LEVEL (OPTIONAL) ROUND SPIRAL RETURN AIR, CHARACTER RELATESTO Z FLAT OVAL RETURN AIR, TRANSFER AIR DUCTWORK ASSOCIATED AIR HANDLER (OPTIONAL) TRANSFER AIR DUCTWORK C CL_LJ TRANSFER AIR DUCTWORK DROP DROP DROP RECTANGULAR EXHAUST AIR,� ROUND SPIRAL EXHAUST AIR, FLAT OVAL EXHAUST AIR, RELIEF AIR DUCTWORK RISE L4 I RELIEF AIR DUCTWORK RISE RELIEF AIR DUCTWORK RISE RECTANGULAR EXHAUST AIR, ROUND SPIRAL EXHAUST AIR, RELIEF AIR DUCTWORK DROP FLAT OVAL EXHAUST AIR, RELIEF AIR DUCTWORK DROP RELIEF AIR DUCTWORK DROP DUCTWORK CONSTRUCTED OF R DUCTWORK RISE IN DIRECTION D DUCTWORK DROP IN DIRECTION OF FLOW AL SS ALUMINUM, STAINLESS STEEL OF FLOW 20' 30' STANDARD DEGREE ANGLESUPPLY AIROUTSIDE AIR IN , ' RETURN AIR, EXHAUST AIR, TRANSFER AIR, REUEF AIR IN TRANSITION IN DIRECTION OF DIRECTION OF FLOW DIRECTION OF FLOW FLOW RECTANGULAR TO ROUND, ECCENTRIC DUCT TRANSITION CONCENTRIC DUCT TRANSITION FLAT OVAL DUCT TRANSITION I VOLUME DAMPER SAD] AD— ACCESS DOOR DUCTWORK CAP I MOTORIZED DAMPER WITH I I FIRE DAMPER WITH ACCESS DOOR I I SMOKE DAMPER WITH ACCESS DO ACCESS DOOR I BACK DRAFT DAMPER WITH I AIRFLOW MEASURING STATION DOOR I I DMOKE DAMPER LHRH ACCESS AND ACCESS DOOR WITH ACCESS I PRESSURE SENSOR WITH I TEMPERATURE SENSOR WITHI ACCESS DOOR SMOKE DETECTOR WITH ACCESS DOOR ACCESS DOOR DUCTWORK LINING OR DOUBLE STATIC PRESSURE CHANGE IN FLEXIBLE DUCTWORK — — — WALL DUCTWORK, DESIGNATION INCHES CONNECTION — — — SHOWN IS FREE AREA 45' BEVELED FITTING FOR RECTANGULAR TO RADIUS DUCTWORK ELBOW (CENTERLINE RADIUS 1.50) � SOUND ATTENUATOR RECTANGULAR DUCTWORK CONICAL FITTING FOR ROUND OR FLAT OVAL TO RADIUS DUCTWORK ELBOW WITH TURNING VANES ItT MITERED DUCTWORK ELBOW RECTANGULAR DUCTWORK LLL CONICAL FITTING FOR ROUND OR FLAT OVAL TO ROUND OR ' -��.1( WYE RADIUS DUCTWORK ELBOW MITERED DUCTWORK ELBOW WITH TURNING VANES FLAT OVAL DUCTWORK 45' LATERAL FITTING FOR ROUND FLIT OVAL TO ROUND OR 45' RADIUS DUCTWORK ELBOWC� RADIUS 1.5xW) u TRANSFER AIR ELBOW WITHOR DUCTWORK STUBS FOR (CENTERLINE SOUND ATTENUATION FLAT OVAL DUCTWORK SPIN -IN FITTING FOR ROUND TO RECTANGULAR DUCTWORK, TO ® CEIUNG PANEL SUPPLY AIR SUPPLY AIR DIFFUSER LOW PRESSURE DUCTWORK DIFFUSER FLEXIBLE DUCTWORK ® RECTANGULAR SUPPLY AIR m RETURN AIR, EXHAUST AIR, TRANSFER AIR REGISTER OR CONNECTION TO DIFFUSER, REGISTER GRILLE MAXIMUM SIX FEET SIDEWALL RETURN AIR, LINEAR SLOT SUPPLY AIR SIDEWALL SUPPLY AIR F -VM EXHAUST AIR, TRANSFER AUR Q DIFFUSER REGISTER OR GRILLE REGISTER OR GRILLE THERMOSTAT WITH ASSOCIATED DOOR GRILLE OR UNDERCUT EQUIPMENT DESIGNATION O TEMPERATURE SENSOR DOOR (TU -12.34) (OPTIONAL) HUMIDISTAT WITH ASSOCIATED EQUIPMENT DESIGNATION ® CARBON DIOXIDE SENSOR CEILING DESTRATIFICATION FAN (TU -12.34) (OPTIONAL) ® TEMPERATURE CONTROL ® VARIABLE FREQUENCY DRIVEr,y CENTRIFUGAL AN RIFUGAL ROOF EXHAUST PANEL HYDRONIC REHEAT COIL WITH TERMINAL UNIT WITH INUNE FAN ACCESS DOOR � HYDRONIC REHEAT COIL ELECTRIC REHEAT COIL WITH TERMINAL UNIT WITH ELECTRIC SERIES/POWEREDARALLEL TERMINALAUNIT ACCESS DOOR REHEAT COIL ® BASE MOUNTED PUMP G-� UNIT VENTILATOR UNIT HEATER HEAT EXCHANGER AIR SEPARATOR o FINNED TUBE RADIATION REFERENCE SYMBOLS SECTION INDICATOR: REFERENCE SECTION LOCATION THROUGH AN AREA FOR KEYNOTE INDICATOR: SHEET KEYNOTE LOCATION FOR ADDITIONAL GENERAL MECHANICAL ADDITIONAL INFORMATION. NOTES: NFORENCE SECTION LOCATION BEYOND AREA KEYNOTE INDICATORS IN DRAWING MODULE EXTENSION NUMERIC CHARACTER SHEET KEYNOTES: RELATES TO ITEM Al PLAN POINT LEADER '; 1 1 1 AREA LEADER M-401 SECTION LOCATION AT SUBSET SHEET LINE LEADER DETAIL INDICATOR: REFERENCE DETAIL LOCATION FOR ADDITIONAL DRAWING BLOCK TITLE REFERENCE DRAWING MODULE LOCATION FOR EQUIPMENT, PIPING OR MATERIALS. INFORMATION. INDICATOR: ADDITIONAL INFORMATION. LARGE SCALE VIEW LOCATION DETAIL LOCATION IN MODULE DRAWING MODULE LOCATION LOWER LEFT OF MULTIPLE MODULES) IN DRAWING MODULE DRAWING (IDENTIFYING Al / ^ DRAWING BLOCK TITLE �` Al M-401 M-501 Al scAUF t/s• = 1'-0• 0 4' a' ts' NUMERIC SCALE- GRAPHIC SCALE -/NORTH ARROW LARGE SCALE VIEW LOCATION DETAIL LOCATION AT AT SUBSET SHEET SUBSET SHEET MATCH LINE INDICATOR: REFERENCE SHEET LOCATION FOR ADDITIONAL REVISION INDICATOR: REFERENCE TITLE BLOCK LOCATION FOR ADDITIONAL INFORMATION. INFORMATION. FLOOR PLAN OVERLAP BEYOND AREA EXTENSION SEE M-102 REVISION INDICATOR /1 � REFER TO ADDITIONAL 7� PLAN SHEET FOR CONTINUATION REVISION CLOUD EQUIPMENT INDICATOR: REFERENCE SCHEDULE LOCATION FOR ADDITIONAL DIFFUSER, GRILLE, REFERENCE SCHEDULE LOCATION FOR ADDITIONAL INFORMATION. REGISTER INDICATOR: INFORMATION. TU-XL� NUMERIC CHARACTER RELATES TO ITEM ALPHANUMERIC CHARACTER RELATES TO BUILDING LEVEL (OPTIONAL) MULTIPLIER (OPTIONAL) � SCHEDULE TYPE (TYP.#)ALPHANUMERIC CHARACTER RELATESTO Z ASSOCIATED AIR HANDLER (OPTIONAL) AIRFLOW (CUBIC FEET PER MINUTE) IPMENT TYPE M 5 GENERAL MECHANICAL NOTE A. ALL WORK SHALL BE IN ACCORDANCE WITH THE BEST QUALITY STANDARDS OF THE TRADE, AND SHALL CONFORM WITH ALL FEDERAL, STATE, AND LOCAL CODES AND STANDARDS. THE SAME ARE MADE A PART OF THESE CONTRACT DOCUMENTS AS IF REPEATED HEREIN. B. CONTRACT DOCUMENTS CONSIST OF BOTH THE PROJECT MANUAL AND DRAWINGS, AND BOTH ARE INTENDED TO BE COMPLEMENTARY. ANYTHING APPEARING ON EITHER MUST BE EXECUTED THE SAME AS IF SHOWN ON BOTH. C. THE CONTRACTOR SHALL INCLUDE IN BID PROPOSAL ALL COSTS REQUIRED TO COMPLETELY AND PROPERLY INSTALL ALL WORK REQUIRED FOR THE PROJECT, AND SHALL EXAMINE THE SCOPE OF WORK OF OTHER TRADES PRIOR TO SUBMITTING A BID PROPOSAL. D. CONSTRUCTION DOCUMENTS SHALL BE FOLLOWED AS CLOSELY AS POSSIBLE, HOWEVER, SYSTEMS HAVE BEEN SHOWN DIAGRAMATICALLY AND IN SOME CASES, ENLARGED FOR CLARITY. ANY OFFSETS, ADDITIONAL FITTINGS, AND/OR APPURTENANCES REQUIRED TO PROVIDE A COMPLETE AND COORDINATED SYSTEM SHALL BE BORNE BY THE CONTRACTOR. E. THE ENGINEERING DRAWINGS ARE OF EQUAL IMPORTANCE WITH THE ARCHITECTURAL DRAWINGS IN DEFINING THE WORK OF THE CONTRACT DOCUMENTS. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO CHECK WITH THE ARCHITECTURAL DRAWINGS BEFORE THE INSTALLATION OF ENGINEERING WORK. SHOULD THERE BE A DISCREPANCY BETWEEN THE ARCHITECTURAL DRAWINGS AND THE ENGINEERING DRAWINGS THAT WOULD CAUSE AN AWKWARD OR IMPROPER INSTALLATION, THE DISCREPANCY SHALL BE BROUGHT TO THE ARCHITECTS/ENGINEERS ATTENTION FOR CLARIFICATION PRIOR TO INSTALLATION OF SAID WORK. ANY WORK INSTALLED IN CONFLICT WITH THE ARCHITECTURAL DRAWINGS SHALL BE CORRECTED BY THE CONTRACTOR AT HIS EXPENSE AND AT NO ADDITIONAL COST TO THE OWNER OR ARCHITECT/ENGINEER. F. DO NOT SCALE THE DRAWINGS. THE DRAWINGS ARE NOT NECESSARILY TO SCALE, THE CONTRACTOR SHALL VERIFY ALL CONDITIONS AND DIMENSIONS AT THE JOB SITE PRIOR TO THE START OF CONSTRUCTION. IF DISCREPANCIES ARE FOUND, THE ARCHITECT/ENGINEER SHALL BE NOTIFIED FOR CLARIFICATION BEFORE COMMENCING THE WORK. EXPLICIT DIMENSIONS SHALL HAVE PRECEDENCE OVER SCALE. G. CONTRACTOR SHALL FIELD VERIFY ALL EXISTING CONDITIONS PRIOR TO BIDDING OR BEGINNING WORK ON THIS PROJECT. H. DETAILS NOT SHOWN ARE SIMILAR IN CHARACTER TO THOSE SHOWN. WHERE SPECIFIC DIMENSIONS, DETAILS OR DESIGN INTENT CANNOT BE DETERMINED, CONSULT THE ARCHITECT/ENGINEER BEFORE PROCEEDING WITH THE WORK. I. ANY DETAILS, SYSTEMS AND/OR MATERIALS WHICH ARE PROPOSED TO BE CHANGED MUST FIRST BE REVIEWED BY THE OWNER AND ARCHITECT/ENGINEER PRIOR TO THE PREPARATION OF SHOP DRAWINGS. J. REFER TO MANUFACTURER'S INSTALLATION INSTRUCTIONS AND TEMPLATE DRAWINGS FOR ALL MECHANICAL EQUIPMENT SUPPORTS, BOLT SETTING TEMPLATES, ISOLATORS, SPRING ISOLATION, ETC., NOT SHOWN ON THE DRAWINGS. K. REFER TO ARCHITECTURAL REFLECTED CEILING PLANS FOR EXACT LOCATION OF CEIUNG MOUNTED MATERIALS INCLUDING ALL DIFFUSERS, GRILLES, AND REGISTERS. L. CONTRACTOR SHALL CLOSE ALL UNUSED OPENINGS IN EXISTING DUCTWORK. M. ALL DUCTWORK DESIGNATIONS REFER TO NET FREE AREA INSIDE THE DUCTWORK. N. VOLUME DAMPERS SHALL BE LOCATED AT BRANCH CONNECTION TO THE MAIN. 0. A MAXIMUM OF SIX FEET OF FLEXIBLE DUCTWORK MAY BE USED AT ALL SUPPLY DIFFUSERS. BRANCH DUCTWORK TO DIFFUSER SHALL BE SAME SIZE AS DIFFUSER INLET UNLESS SPECIFICALLY LABELED OTHERWISE. REFER TO DIFFUSER SCHEDULE FOR INLET SIZES. AVOID SHARP BENDS IN FLEXIBLE DUCTWORK WHICH MAY CAUSE EXCESSIVE NOISE. P. BRANCH DUCTWORK TO TERMINAL UNITS SHALL BE SAME SIZE AS TERMINAL UNIT INLET UNLESS SPECIFICALLY LABELED OTHERWISE. REFER TO TERMINAL UNIT SCHEDULE FOR INLET SIZES. NOTATION DESIGNATORS GENERAL NOTES: NOTES THAT APPLY EQUALLY TO ALL DISCIPLINES A-000 WITHIN THE DRAWING SET. GENERAL MECHANICAL NOTES THAT APPLY EQUALLY TO ALL SHEETS WITHIN NOTES: THE DISCIPLINE. GENERAL SHEET NOTES THAT APPLY ONLY TO THE SPECIFIC SHEET ON NOTES: WHICH THEY APPEAR. SHEET KEYNOTES: NOTES THAT APPLY ONLY TO THE SPECIFIC SHEET ON M-700 WHICH THEY APPEAR AND USE A KEYNOTE INDICATOR M-800 TO IDENTIFY ITEMS. U w O a N S IMM O H >M_ a a a SUBSET DESIGNATORS G-000 GENERAL A-000 ARCHITECTURAL F-000 FIRE SUPPRESSION P-000 PLUMBING M-000 MECHANICAL E-000 ELECTRICAL T-000 TELECOMMUNICATION SHEET TYPE DESIGNATORS M-000 GENERAL (SYMBOLS, ABBREVIATIONS, NOTES) M-100 PLANS (DEMOLITION, SITE, FOUNDATION) M-200 PLANS (DUCTWORK, PLUMBING) M-300 PLANS (HYDRONIC PIPING) M-400 LARGE SCALE VIEWS (PLANS, SECTIONS) M-500 DETAILS M-600 SCHEDULES M-700 SHORT SPECIFICATIONS M-800 DIAGRAMS (CONTROLS, RISERS, ONE-UNES) M-900 3D REPRESENTATIONS (ISOMETRICS) Q LINETYPE DESIGNATORS THIN CONTINUOUS UNETYPE INDICATE EXISTING ITEMS TO REMAIN. INTERMEDIATE DASHED UNETYPE INDICATE EXISTING ITEMS TO --- BE REMOVED. INTERMEDIATE OR WIDE CONTINUOUS UNETYPE INDICATE NEW ITEMS. THIN HALFTONE UNETYPE INDICATE ITEMS BY OTHER DISCIPLINE. INDICATES POINT OF NEW CONNECTION TO EXISTING is EQUIPMENT, PIPING OR MATERIALS. INDICATES POINT OF DISCONNECTION TO EXISTING 19 EQUIPMENT, PIPING OR MATERIALS. 5 J J a 0 z 0 C 10011 0 ENGINEER VACQUIS CONSULTING ENGINEERS 9229 DELEGATES RO`✓V, SUITE 550 INDIANAPOLIS, IN 46240 317.706.2075 WWW.LACQUIS.COM •r� `i��nn�llmnrnmA, NO. -� 10061168 w� ;TATE OF 7 �1 PROJECT CARMEL MASTER FIRE STATION f, IAX Steven A. Couts Fire Headquarters, Station 41 2 Civic Square Carmel, In 46032 MARK DATE DESCRIPTION ISSUE DATE: 5/13/2011 CLIENT NO: 00000 PROJECT NO: 09106 CAD FILE: M-001.DW'C DRAWN BY: SBS CHECKED BY: AJM © Copyright, L'Acquis Consulting Engineers 11 SHEEP TITLE II MECHANICAL SYMBOLS AND ABBREVIATIONS M-001