Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
20
PUMP SCHEDULE 1 LOCATION SYSTEM TYPE DESIGN CAPACITY (GPM) 2 MIN Ems• PUMP MOTOR DATA SPECIFICATION SECTION MANUFACTURER WITH MODEL NUMBER NOTES SUCT. (IN) 3 HP RPM VOLTS 4 5 CWP -1 SECOND FLOOR SOUTH MEZZANINE COOLING WATER IN-LINE MOUNTED 63 53 56.12 1.5 1.5 2 3450 208 3 232123 BELL & GOSSETT 90 1-1/2AA HEATING WATER CWP -2 SECOND FLOOR SOUTH MEZZANINE COOLING WATER IN-LINE MOUNTED 63 53 56.12 1.5 1.5 2 3450 208 3 232123 BELL & GOSSETT 90 1-1/2AA ABB ACH550-UH-017A-2 HWP-1 SECOND FLOOR SOUTH MEZZANINE HEATING WATER IN-LINE MOUNTED 125 57 62.5 2 2 5 3450 208 3 232123 BELL & GOSSETT 90 2AA MAGIC AIRE #BVE16 HWP-2 SECOND FLOOR SOUTH MEZZANINE HEATING WATER IN-LINE MOUNTED 125 57 62.5 2 2 5 3450 208 3 232123 BELL & GOSSETT 90 2AA 18 5.36 48.2 39.1 78 65 57.5 55.9 4 45 9.5 5.72 2" THROWAWAY 349 238200 MAGIC AIRE #BVE20 - NOTES 1. 203 MECH VERTICAL 2,000 .25 922 1 115 1 61.8 64.0 89.4 2 128 26 10.92 51.3 42.3 78 65 58.1 56.1 4 45 10 6.26 2" THROWAWAY 355 238200 MAGIC AIRE #BVE20 FCU -4 204 MECH VERTICAL 1,520 .25 948 0.75 115 1 43.6 64.0 90.2 2 128 13 10.27 37.7 31.9 78 65 58.2 56.6 4 45 7.5 5.61 2" THROWAWAY 298 238200 MAGIC AIRE #BVE16 FCU -5 204 MECH VERTICAL 1,520 .25 948 0.75 115 1 43.6 D 90.2 2 128 13 10.27 37.7 31.9 78 65 58.2 56.6 4 45 7.5 5.61 2" THROWAWAY 298 238200 D 10/10 FCU -6 204 MECH VERTICAL 1,900 .25 8gg 1 115 1 58.2 64.0 89.2 2 128 20 6.56 50.2 40.9 78 65 57.7 56.0 4 45 10 6.26 2" THROWAWAY 355 238200 MAGIC AIRE #BVE20 FCU -7 137 MECH VERTICAL 1,520 .25 948 0.75 115 1 43.6 64.0 90.2 2 128 13 10.27 37.7 31.9 78 65 58.2 56.6 4 45 7.5 5.61 2" THROWAWAY 298 238200 MAGIC AIRE #BVE16 FCU -8 216 MECH VERTICAL 1,520 .25 948 0.75 115 1 43.6 64.0 90.2 2 128 13 10.27 37.7 31.9 78 65 58.2 56.6 4 45 7.5 5.61 2" THROWAWAY 298 238200 MAGIC AIRE #BVE16 FCU -9 216 MECH VERTICAL 1,520 .25 948 0.75 115 1 43.6 64.0 90.2 2 128 13 10.27 37.7 31.9 78 65 58.2 56.6 4 45 7.5 5.61 2" THROWAWAY 298 238200 MAGIC AIRE #BVE16 FCU -10 216 MECH VERTICAL 2,000 .25 922 1 115 1 61.5 64.0 89.3 2 128 25 10.12 51.3 42.3 78 65 58.1 56.3 4 45 10 6.26 2" THROWAWAY 355 238200 MAGIC AIRE #BVE20 FCU -11 132 MECH VERTICAL 2,000 .25 922 1 115 1 61.5 64.0 89.3 2 128 25 10.12 51.3 42.3 78 65 58.1 56.3 4 45 10 6.26 2" THROWAWAY 355 238200 MAGIC AIRE #BVE20 NOTES: C C1. DAMPER SCHEDULE AIRFLOW MARK LOCATION SYSTEM SERVED BLADE TYPE CONTROL DAMPER FAIL ACTUATOR TYPE SPECIFICATION MANUFACTURER WITH NOTES ACTION MAX MIN SIZE POSITION SECTION MODEL NUMBER CFM CFM D-1 203 MECH VENTILATION SINGLE BLADE OPEN/CLOSED 80 80 6"0 - MANUAL 233300 RUSKIN CDRS25 B D-2 203 MECH VENTILATION SINGLE BLADE OPEN/CLOSED 115 115 8"� - MANUAL 233300 RUSKIN CDRS25 B D-3 203 MECH VENTILATION SINGLE BLADE OPEN/CLOSED 115 115 8"0 - MANUAL 233300 RUSKIN CDRS25 D-4 204 MECH VENTILATION SINGLE BLADE OPEN/CLOSED 90 90 8"0 - MANUAL 233300 RUSKIN CDRS25 D-5 204 MECH VENTILATION SINGLE BLADE 3 POSITION 115 30 8"0 CLOSED SPRING RETURN 233300 RUSKIN CDRS25 1 D-6 204 MECH VENTILATION SINGLE BLADE OPEN/CLOSED 125 125 8"0 - MANUAL 233300 RUSKIN CDRS25 D-7 138 MECH/ELECT VENTILATION SINGLE BLADE OPEN/CLOSED 145 40 8"0 CLOSED SPRING RETURN 233300 RUSKIN CDRS25 1 D-8 216 MECH VENTILATION SINGLE BLADE 3 POSITION 185 55 8"0 CLOSED SPRING RETURN 233300 RUSKIN CDRS25 1 D-9 216 MECH VENTILATION SINGLE BLADE OPEN/CLOSED 100 100 8"0 - MANUAL 233300 RUSKIN CDRS25 D-10 216 MECH VENTILATION SINGLE BLADE OPEN/CLOSED 140 140 8"0 - MANUAL 233300 RUSKIN CDRS25 D-11 210 MEN'S DORM VENTILATION SINGLE BLADE 3 POSITION 160 55 8"0 A A 1 2 3 4 5 PUMP SCHEDULE MARK LOCATION SYSTEM TYPE DESIGN CAPACITY (GPM) DESIGN CAPACITY (FT. HD) MIN Ems• PUMP MOTOR DATA SPECIFICATION SECTION MANUFACTURER WITH MODEL NUMBER NOTES SUCT. (IN) DISCH (IN) HP RPM VOLTS PH CWP -1 SECOND FLOOR SOUTH MEZZANINE COOLING WATER IN-LINE MOUNTED 63 53 56.12 1.5 1.5 2 3450 208 3 232123 BELL & GOSSETT 90 1-1/2AA HEATING WATER CWP -2 SECOND FLOOR SOUTH MEZZANINE COOLING WATER IN-LINE MOUNTED 63 53 56.12 1.5 1.5 2 3450 208 3 232123 BELL & GOSSETT 90 1-1/2AA ABB ACH550-UH-017A-2 HWP-1 SECOND FLOOR SOUTH MEZZANINE HEATING WATER IN-LINE MOUNTED 125 57 62.5 2 2 5 3450 208 3 232123 BELL & GOSSETT 90 2AA MAGIC AIRE #BVE16 HWP-2 SECOND FLOOR SOUTH MEZZANINE HEATING WATER IN-LINE MOUNTED 125 57 62.5 2 2 5 3450 208 3 232123 BELL & GOSSETT 90 2AA 18 5.36 48.2 39.1 78 65 57.5 55.9 4 45 9.5 5.72 2" THROWAWAY 349 238200 MAGIC AIRE #BVE20 - NOTES 1. VARIABLE FREQUENCY DRIVE SCHEDULE MARK LOCATION SYSTEM HP ELECTRICAL DATA SPECIFICATION SECTION MANUFACTURER WITH MODEL NUMBER NOTES AMPS VOLTS PH VFD-1 SECOND FLOOR SOUTH MEZZANINE COOLING WATER 2 7.5 208 3 200035 ABB ACH550-UH-07A5-2 1 VFD-2 SECOND FLOOR SOUTH MEZZANINE COOLING WATER 2 7.5 208 3 200035 ABB ACH550-UH-07A5-2 1 VFD-3 SECOND FLOOR SOUTH MEZZANINE HEATING WATER 5 16.7 208 3 200035 ABB ACH550-UH-017A-2 1 VFD-4 SECOND FLOOR SOUTH MEZZANINE HEATING WATER 5 16.7 208 3 200035 ABB ACH550-UH-017A-2 1 13.47 38.6 32.9 78 65 58.6 56.9 4 45 7.5 NOTES: 1. WALL MOUNTED UNIT. FRAME SIZE IS R1. PROVIDE WITH BYPASS. FAN COIL UNIT SCHEDULE (4 -PIPE) MARK LOCATION CONFIGURATION SUPPLY FAN DATA HYDRONIC HEATING COIL SELECTION DATA HYDRONIC COOLING COIL SELECTION DATA FILTER TYPE UNIT WEIGHT (�S) SPECIFICATION SECTION MANUFACTURER WITH MODEL NUMBER NOTES SUPPLY CFM ESP RPM HP VOLTS PH MIN MBH EAT LAT ROWS EWT GPM MAX WPD TOTAL MBH SENS MBH �`T �`T ROWS EWT GPM MAX WPD DB WB DB WB FCU -1 203 MECH VERTICAL 1,600 .25 984 1 115 1 45.6 64.0 90.0 2 128 15 13.47 38.6 32.9 78 65 58.6 56.9 4 45 7.5 5.61 2" THROWAWAY 304 238200 MAGIC AIRE #BVE16 0.006 FCU -2 203 MECH VERTICAL 1,800 .25 856 0.75 115 1 55.8 64.0 89.5 2 128 18 5.36 48.2 39.1 78 65 57.5 55.9 4 45 9.5 5.72 2" THROWAWAY 349 238200 MAGIC AIRE #BVE20 - FCU -3 203 MECH VERTICAL 2,000 .25 922 1 115 1 61.8 64.0 89.4 2 128 26 10.92 51.3 42.3 78 65 58.1 56.1 4 45 10 6.26 2" THROWAWAY 355 238200 MAGIC AIRE #BVE20 FCU -4 204 MECH VERTICAL 1,520 .25 948 0.75 115 1 43.6 64.0 90.2 2 128 13 10.27 37.7 31.9 78 65 58.2 56.6 4 45 7.5 5.61 2" THROWAWAY 298 238200 MAGIC AIRE #BVE16 FCU -5 204 MECH VERTICAL 1,520 .25 948 0.75 115 1 43.6 64.0 90.2 2 128 13 10.27 37.7 31.9 78 65 58.2 56.6 4 45 7.5 5.61 2" THROWAWAY 298 238200 MAGIC AIRE #BVE16 10/10 FCU -6 204 MECH VERTICAL 1,900 .25 8gg 1 115 1 58.2 64.0 89.2 2 128 20 6.56 50.2 40.9 78 65 57.7 56.0 4 45 10 6.26 2" THROWAWAY 355 238200 MAGIC AIRE #BVE20 FCU -7 137 MECH VERTICAL 1,520 .25 948 0.75 115 1 43.6 64.0 90.2 2 128 13 10.27 37.7 31.9 78 65 58.2 56.6 4 45 7.5 5.61 2" THROWAWAY 298 238200 MAGIC AIRE #BVE16 FCU -8 216 MECH VERTICAL 1,520 .25 948 0.75 115 1 43.6 64.0 90.2 2 128 13 10.27 37.7 31.9 78 65 58.2 56.6 4 45 7.5 5.61 2" THROWAWAY 298 238200 MAGIC AIRE #BVE16 FCU -9 216 MECH VERTICAL 1,520 .25 948 0.75 115 1 43.6 64.0 90.2 2 128 13 10.27 37.7 31.9 78 65 58.2 56.6 4 45 7.5 5.61 2" THROWAWAY 298 238200 MAGIC AIRE #BVE16 FCU -10 216 MECH VERTICAL 2,000 .25 922 1 115 1 61.5 64.0 89.3 2 128 25 10.12 51.3 42.3 78 65 58.1 56.3 4 45 10 6.26 2" THROWAWAY 355 238200 MAGIC AIRE #BVE20 FCU -11 132 MECH VERTICAL 2,000 .25 922 1 115 1 61.5 64.0 89.3 2 128 25 10.12 51.3 42.3 78 65 58.1 56.3 4 45 10 6.26 2" THROWAWAY 355 238200 MAGIC AIRE #BVE20 NOTES: UACOUIS100%W DIFFUSERS &GRILLES SCHEDULE MARK MAX CFM DIMENSIONAL DATA THROW DATA PRESS. DROP CIN. WC.) � NC SOUND LEVEL ACCESSORIES SPECIFICATION SECTION MANUFACTURER WITH MODEL NUMBER FACE SIZE SLOT INFO CONN. SIZE DIRECTION DISTANCE ®NOM. CFM BALANCE DAMPER PLENUM BOOT TAMPER- PROOF SCREWS SD1 175 24"x24" - 60 4 -WAY 4' 0.045 16 - - - 233713 TITUS TMS SD2 275 24"x24" - 8� 4 -WAY 5' 0.040 18 - - - 233713 TITUS TMS SIZE TYPE z � nom. NOTES: 1 • PROVIDE 13.5" RCG-16 ROOF CURB AND BIRDSCREEN. TYPE SG1 100 10"x6" 3/4" ®45' 60 1 -DEFLECTION 6' 0.006 <12 - - - 233713 TITUS 301 FL NO HUB NICKEL BRONZE 8" ROUND NO YES NO NO 221316 JR SMITH #2005 1 RG1 850 12"x24" 1/2" � 35' 24/12 - - 0.014 <20 - - - 233713 TITUS 355 FL RG2 100 10"x6" 3/4" ®35' 0.006 <12 - - - 233713 TITUS 350 FL CLOSED SPRING RETURN 233300 RUSKIN CDRS25 1 D-12 206 LOCKERS VENTILATION OPPOSED BLADE 3 POSITION 425 55 12/12 CLOSED SPRING RETURN 233300 RUSKIN 1 D-13 203 MECH VENTILATION OPPOSED BLADE 3 POSITION 310 25 10/10 CLOSED SPRING RETURN 233300 RUSKIN 1 D-14 223 STORAGE VENTILATION OPPOSED BLADE 3 POSITION 330 30 12/12 CLOSED SPRING RETURN 233300 RUSKIN 1 NOTES: 1. PROVIDE 120 VOLT DAMPER ACTUATOR TO BE FIELD INSTALLED BY MECHANICAL CONTRACTOR. DIFFUSERS &GRILLES SCHEDULE MARK MAX CFM DIMENSIONAL DATA THROW DATA PRESS. DROP CIN. WC.) � NC SOUND LEVEL ACCESSORIES SPECIFICATION SECTION MANUFACTURER WITH MODEL NUMBER FACE SIZE SLOT INFO CONN. SIZE DIRECTION DISTANCE ®NOM. CFM BALANCE DAMPER PLENUM BOOT TAMPER- PROOF SCREWS SD1 175 24"x24" - 60 4 -WAY 4' 0.045 16 - - - 233713 TITUS TMS SD2 275 24"x24" - 8� 4 -WAY 5' 0.040 18 - - - 233713 TITUS TMS SIZE TYPE z � nom. NOTES: 1 • PROVIDE 13.5" RCG-16 ROOF CURB AND BIRDSCREEN. TYPE SG1 100 10"x6" 3/4" ®45' 60 1 -DEFLECTION 6' 0.006 <12 - - - 233713 TITUS 301 FL NO HUB NICKEL BRONZE 8" ROUND NO YES NO NO 221316 JR SMITH #2005 1 RG1 850 12"x24" 1/2" � 35' 24/12 - - 0.014 <20 - - - 233713 TITUS 355 FL RG2 100 10"x6" 3/4" ®35' 0.006 <12 - - - 233713 TITUS 350 FL ENGINEER � CONSULTING ENGINEERS 9229 DELEGATES ROAN, SUITE 550 INDIANAPOLIS, IN 46240 317.706,2075 W W W.LACQUIS.COM CONSULTANT 61 8 East Market Street Indianapolis, Indiana 46202 ph 31 ;'?5a.dld2 Fx 317/Z6e.d.65 a x i s a r c h c o m PROJECT CARMEL MASTER ROOF INTAKE HOOD SCHEDULE MARK CFM Station 41 HOOD SIZE THROAT SIZE INTAKE VELOCITY THROAT VELOCITY STATIC PRESSURE BIRDSCREEN ROOF CURB SPECIFICATION SECTION MANUFACTURER WITH MODEL NUMBER NOTES DIA. DIA. IH -1 310 18-3/4" 8-5/8" 225 787 0.075 YES SPECIFICATION YES 233723 LOREN COOK 8PRI 1 MATERIAL OUTLET OUTLET MATERIAL SIZE TYPE z � nom. NOTES: 1 • PROVIDE 13.5" RCG-16 ROOF CURB AND BIRDSCREEN. ENGINEER � CONSULTING ENGINEERS 9229 DELEGATES ROAN, SUITE 550 INDIANAPOLIS, IN 46240 317.706,2075 W W W.LACQUIS.COM CONSULTANT 61 8 East Market Street Indianapolis, Indiana 46202 ph 31 ;'?5a.dld2 Fx 317/Z6e.d.65 a x i s a r c h c o m PROJECT CARMEL MASTER FLOOR DRAIN SCHEDULE Steven A. Couts Fire Headquarters, Station 41 DRAIN BODY STRAINER Carmel, In 46032 I � z J I it I° MANUFACTURER MARK DESCRIPTION �, A ,�, z o ,�, SPECIFICATION WITH MODEL NOTES MATERIAL OUTLET OUTLET MATERIAL SIZE TYPE z � nom. N m � SECTION NUMBER TYPE FD -1 FLOOR DRAIN #1 CAST IRON 4" NO HUB NICKEL BRONZE 8" ROUND NO YES NO NO 221316 JR SMITH #2005 1 NOTES: 1. INSTALL DEEP SEAL P -TRAP. ENGINEER � CONSULTING ENGINEERS 9229 DELEGATES ROAN, SUITE 550 INDIANAPOLIS, IN 46240 317.706,2075 W W W.LACQUIS.COM CONSULTANT 61 8 East Market Street Indianapolis, Indiana 46202 ph 31 ;'?5a.dld2 Fx 317/Z6e.d.65 a x i s a r c h c o m PROJECT CARMEL MASTER FIRE STATION Steven A. Couts Fire Headquarters, Station 41 2 Civic Square Carmel, In 46032 I I it I° ISSUE DATE: 5/13/2011 CLIENT N0: 00000 PROJECT N0: 09106 CAD FILE: M-601.D`rVG DRAWN BY: S B S CHECKED BY: AJM ©Copyright, L'Acquis Consulting Engineers SHEET TITLE MECHANICAL SCHEDULES M-601