Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
25
II D II C it B Elm N r CD 1 1 2 3 4 LIGHTING 'llFfX "Uf IE SCHEt71JLE NO OF TYPE RASE MANUFACTURER EQUAL MANUFACTURER EQUAL MANUFACTURER LAMP TY PE VOLTS i MC`JNT�NG CESCRIP77�ON LAS'+ PKS LITHONIA QR APPROVEIa EQUAL OR APPROVED EQUAL � �,r � 2x'2' G -R, ..AY- N REGRESSE-0 ALUMINUM DOOR VH&T ; 1 MRS Al 2SP5-G2U31R-RW-A12125• ! 41 OO 12 RECESS GER I ORS-LP841 NOTES: 1. SEE SPECIF€CATIONS FOR BALLAST MANUFACTURERS FOR LINEAR F_UORESCENT AND COMPAICT FLIJORESCENT.ANIPS. 5 GENERAL NOTES A. ALL EXISTING ELECTRICAL CIRCUITS SHALL REMAIN IN OPERATION DURING THE RENOVATION. ANY POWER OUTAGE REQUIRED BY THIS WORK SHALL BE APPROVED AND SCHEDULED BY THE OWNER PRIOR TO THE BEGINNING OF WORK. B. EXISTING CONDUIT MAY BE REUSED WHERE PRACTICABLE. WHERE CONDUIT IS REUSED, ALL EXISTING WIRING SHALL BE REPLACED WITH NEW. WHERE EXISTING CONDUIT 2 Civic Square EXTENDED TO AN ADJACENT PANEL IN THE SAME ROOM, REMAINING CONDUIT TO THE Carmel, In 46032 ORIGINATING PANEL SHALL BE REMOVED AND PANEL OPENINGS BLANKED OFF. C. ALL EXISTING PANEL CIRCUIT DIRECTORIES MODIFIED BY THESE DRAWINGS SHALL BE REPLACED WITH COMPUTER GENERATED OR TYPE WRITTEN DIRECTORIES. COPY ALL EXISTING CIRCUIT DESIGNATIONS THAT REMAIN UNCHANGED. WHERE CIRCUIT DELETIONS, CHANGES OR ADDITIONS ARE MADE BY THESE DRAWINGS ADD THE FOLLOWING NOTE TO THE CIRCUIT DESIGNATION AT EACH LINE, (2011 HVAC RENOVATION). O SHEET KEYNOTES 1. PROVIDE COMPATIBLE "EATON/CUTLER—HAMMER" 2P-20AMP BREAKER AT CIRCUIT SPACE SHOWN. 2. CONNECT TO EXISTING CORRIDOR LIGHTING CIRCUIT. AT FIXTURES MARKED 'EM', CONNECT TO EXISTING CORRIDOR EMERGENCY LIGHTING CIRCUIT. 71■ 000 EXISTING MDP 139 138 121 EXISTING PANELS 118 A EM C LE2 HE1 L2 12 EXISTING PANELS F CU -7 L1 122 LE1 140 0 H 143 ® A EM LEA 2-18,201 A F1 El 135 123 A 141 115 A EM 114 F-1 42 134 A 133 0 A A EM _ LE3 113 NEW PANEL LE3 IN Fl -0-1 102 124 125 aD � 2ND FLOOR ROM 203. SEE PANEL SCHEDULE ON F1 12 A 126 DRAWING E-600. 100A B 111 A FM 127 4#2, #8G, 1-1/4" IMC EXISTING PANEL HE1 HE1 — Q IN T FLOOR ROOM 103 109 147 A 38.SPROVIDE COMPATIBLE "EATON/CUTLER—HAMMER" 225A 3P-100 AMP BREAKER 1 AT CIRCUIT SPACE 208/120V 131 13, 15, 17. 30, 4 WIRE LE2-22,24 A EM A A � FN_1 ® PARTIAL RISER DIAGRAM O � 2 )_ SCALE: NTS 144 146 FCU -11 105 132 128 F1 2-9 ELECTRICAL FIRST FLOOR PLAN- SCALE: 3 4i A II ENGINEER i UACQUIS CONSULTING EitiTGINE>cRS 9229 DELEGATES ROW, SUITE 550 INDIANAPOLIS, IN 46240 317.706.2075 WWW .LACQUIS.COM CONSULTANT 61.8 East Market Street IndionapaUs, Indiana 46202 ph 317/264 2162 {x 317/264.8165 o x i i a r c h. c o m ,,, Q' L• `'` y 1I K PEIrrRj r -rV STATE OF =y - < ` T �1 � PROJECT CARMEL MASTER FIRE STATION Steven A. Couts Fire Headquarters, Station 41 2 Civic Square Carmel, In 46032 MARK DATE DESCRIPTION ISSUE CLIENT PROJE( CAD FI DRAWN CHECKI © Copyric SHEET TITLE ELECTRICAL FIRST FLOOR PLAN E-201