HomeMy WebLinkAbout8i M, 0 O Q cD 3 E W 0 a Cl - 0 10 0 C 1 1 2 1 3 1 4 2 3 01 FIRST FL SCALE: 1/8" = 1'-0" OOR REFLECTED CEILING PLAN M GENERAL CEILING PLAN NOTES: A. REUSE EXISTING CEILINGS TO THE GREATEST EXTENT POSSIBLE. SALVAGE EXISTING CEILING TILES AND GRID FOR REINSTALLATION. REINSTALL ONLY CLEAN UNDAMAGED TILES AND GRID. DO NOT MIX NEW TILES AND EXISTING TILES IN THE SAME AREA. DO NOT MIX CEILING TILE - IN AREAS OF REUSED CEILINGS REINSTALL ALL SALVAGED TILES, IN AREAS WHICH REQUIRE NEW CEILING TILE INSTALL ALL NEW CEILING TILE. B. REFER TO CEILING PLANS FOR ALL CEILING HEIGHTS. C. REINSTALL NEW CEILINGS WITH SAME LAYOUT AS EXISTING. D. ALL GRIDS ARE TO BE CENTERED IN ROOMS IN EACH DIRECTION UNLESS NOTED OTHERWISE. E. COORDINATE REFLECTED CEILING PLAN WITH MECHANICAL, PLUMBING AND ELECTRICAL DRAWINGS. F. REFER TO ELECTRICAL DRAWINGS FOR LIGHT FIXTURES, EXIT SIGNS ETC. G. REFER TO MECHANICAL DRAWINGS FOR DIFFUSERS AND OTHER MECHANICAL ITEMS. D CEILING TYPES: A. 2'x 2'x 1 " LAY -IN CEILING TYPE: FINE FISSURED PANEL EDGE TYPE: SQUARE EDGE NON -DIRECTIONAL GRID: 9/16" CHANNEL GRID B. 2'x 2'x 1 " LAY -IN CEILING TYPE: FINE FISSURED PANEL EDGE TYPE: SQUARE EDGE NON -DIRECTIONAL GRID: 15/16" GRID C. GYPSUM BOARD 5/8" GYPSUM WALLBOARD ON ARMSTRONG SUSPENSION SYSTEM. PAINT SEMI GLOSS CEILING WHITE. PROVIDE ACCESS PANELS REQUIRED FOR ACCESS OR SERVICE TO MECHANICAL ITEMS. D. EXISTING DRYWALL CEILING. NOTES: PATCH AND REPAIR HOLES, CRACKS AND OPENINGS TO BRING TO LIKE -NEW CONDITION. E. NO CEILING - OPEN TO STRUCTURE ABOVE NOTES: REFER TO INTERIOR FINISH PLAN FOR PAINT. C CEILING LEGEND: CEILING TYPE A CEILING HEIGHT 9'-0" ME - MATCH EXISTING CEILING HEIGHT 2x2 ACOUSTICAL CEILING TILE GYPSUM BOARD CEILING EXPOSED STRUCTURE CEILING PLAN KEYED NOTES: 1. PATCH CEILING AT PIPING PENETRATIONS. 2. NEW 30" X 42" ATTIC ACCESS DOOR. REFRAME ATTIC STRUCTURE AS REQUIRED. PROVIDE HEADERS AS REQUIRED TO FRAME OPENING. PATCH EXISTING GYPSUM WALLBOARD CEILING. 3. NEW 4-7/8" METAL FRAMING AND DRYWALL BULKHEAD. BOTTOM OF BULKHEAD TO BE 2" BELOW ACOUSTICAL CEILING. 4. INSTALL NEW CEILING BELOW LEVEL OF EXISTING DUCTWORK. VERIFY HEIGHT IN FIELD. 5 0 ENGINEER 9 L ACQUIS CONSULTING ENGINEERS I� I 9229 DELEGATES POW, SUITLI 57,0 INDIANAPOLIS, IN 46240 317.706.2075 W W W.LACQL IS.CONI I CONSULTANT 618 E,w Market Street Indianapolis, Indiana 46202 ph 3 1 7 2 48167 63 1 71964 8165 I a x i s a r c c o m le 1 f� I (Ii I� 1 i !s n.�Qy la\`\a,Ri4iuwmu�rnnu D R i STf,f L �� ap S Q AR -1940008; �* STATE OF 7t %% /ND I AQP PROJECT I ILI I CARMEL MASTER ` FIRE STATION ! Steven A. Couts Fre Headquarters, Station 41 2 Civic Square Carmel, In 46032 MARK I DATE DESCRIPTION ISSUE DATE: 5/13/2011 CLIENT NO: PROJECT NO: 11021 CAD FILE: A401.DWG D RAW N BY: C R H CHECKED BY: DDW © Copyright, L'Acquis Consulting Engineers SHEET TITLE FIRST FLOOR REFLECTED CEILING PLAN A401