HomeMy WebLinkAbout10E. CONCRETE SLAB PRIMER: NON -STAINING TYPE AS RECOMMENDED BY FLOORING MANUFACTURER.
F. LEVELING COMPOUND: LATEX -TYPE AS RECOMMENDED BY FLOORING MANUFACTURER AND COMPATIBLE WITH THE
MEMBRANE WATERPROOFING.
G. WATERPROOFING COMPOUND: ELASTIMENT 300 AS MANUFACTURED BY BOIARDI PRODUCTS CORPORATION, OR APPROVED
EQUAL.
PART 3 - EXECUTION
3.01 PREPARATION
A. BROOM CLEAN OR VACUUM SURFACES TO BE COVERED AND INSPECT SUBFLOOR. THE START OF FLOORING INSTALLATION
INDICATES ACCEPTANCE OF SUBFLOOR CONDITIONS AND FULL RESPONSIBILITY FOR COMPLETED WORK.
B. USE LEVELING COMPOUND AS RECOMMENDED BY FLOORING MANUFACTURER FOR FILLING CRACKS, HOLES AND
DEPRESSIONS IN SUBFLOORS.
C. APPLY CONCRETE SLAB PRIMER, IF RECOMMENDED BY FLOORING MANUFACTURER, PRIOR TO APPLICATION OF ADHESIVE.
APPLY IN COMPLIANCE WITH MANUFACTURER'S DIRECTIONS.
D. WHERE INDICATED, INSTALL WATERPROOF MEMBRANE IN ACCORDANCE WITH APPROVED MANUFACTURER'S INSTRUCTIONS.
3.02 INSTALLATION
A. GENERAL
1. INSTALL FLOORING USING METHOD INDICATED IN STRICT COMPLIANCE WITH MANUFACTURER'S RECOMMENDATIONS.
EXTEND FLOORING INTO TWO SPACES, DOOR REVEALS AND SIMILAR OPENINGS.
2. TIGHTLY CEMENT FLOORING TO SUBSTRATE WITHOUT OPEN CRACKS, VOIDS, RAISING AND PUCKERING AT JOINTS,
TELEGRAPHING OF ADHESIVE SPREADER MARKS OR OTHER SURFACE IMPERFECTIONS. HAND ROLL FLOORING AT
PERIMETER OF EACH COVERED AREA TO ENSURE ADHESION.
B. TILE FLOORS
1. LAY TILE IN PATTERNS AS SHOWN ON THE DRAWINGS, OR IF NOT SHOWN, FROM CENTER MARKS ESTABLISHED WITH
PRINCIPAL WALLS, DISCOUNTING MINOR OFFSETS, SO THAT TILE AT OPPOSITE EDGES OF ROOM AREA OF EQUAL WIDTH.
ADJUST AS NECESSARY TO AVOID USE OF CUT WIDTHS LESS THAN ONE HALF OF A TILE AT ROOM PERIMETERS. LAY TILE
SQUARE TO THE ROOM AXIS, UNLESS OTHERWISE SHOWN.
2. MATCH TILES FOR COLOR AND PATTERN BY USING TILE FROM CARTONS IN SAME SEQUENCE AS MANUFACTURED AND
PACKAGED, IF SO NUMBERED. CUT TILE NEATLY AROUND ALL FIXTURES. BROKEN, CRACKED, CHIPPED OR DEFORMED
TILES ARE NOT ACCEPTABLE. LAY TILE WITH GRAIN RUNNING IN ONE DIRECTION, UNLESS OTHERWISE INDICATED.
3. ADHERE THE TILE FLOORING TO SUBSTRATES USING FULL SPREAD OF ADHESIVE APPLIED IN COMPLIANCE WITH FLOORING
MANUFACTURER'S DIRECTIONS.
C. ACCESSORIES
APPLY BASE TO WALLS AND OTHER PERMANENT FIXTURES IN ROOMS OR AREAS WHERE BASE IS REQUIRED. INSTALL BASE IN
LENGTHS AS LONG AS PRACTICABLE WITH CONTINUOUS RUNS FORMING OUTSIDE CORNERS AND MITERED OR COPED INSIDE
CORNERS. TIGHTLY BOND BASE TO SUBSTRATE THROUGHOUT LENGTH OF EACH PIECE, WITH CONTINUOUS CONTACT AT
HORIZONTAL AND VERTICAL SURFACES. NOTIFY GENERAL CONTRACTOR AND ARCHITECT OF ANY DEVIATIONS IN WALL
SURFACES THAT WILL IMPACT FINISHED INSTALLATION PRIOR TO COMMENCEMENT OF WORK.
3.03 CLEANING AND PROTECTION
A. REMOVE ANY EXCESS ADHESIVE OR OTHER SURFACE BLEMISHES, USING NEUTRAL TYPE CLEANERS AS RECOMMENDED BY
FLOORING MANUFACTURER. PROTECT INSTALLED FLOORING WITH HEAVY KRAFT PAPER OR OTHER COVERING.
B. FINISHING: AFTER COMPLETION OF PROJECT AND JUST PRIOR TO FINAL INSPECTION OF WORK, THOROUGHLY CLEAN
FLOORS AND ACCESSORIES.
C. APPLY POLISH AND BUFF WITH TYPE OF POLISH, NUMBER OF COATS, AND BUFFING PROCEDURES IN COMPLIANCE WITH
FLOORING MANUFACTURER'S INSTRUCTIONS.
END OF SECTION 09650
SECTION 096400 - WOOD FLOORING
PART1- GENERAL
1.1 RELATED DOCUMENTS
A. DRAWINGS AND GENERAL PROVISIONS OF THE CONTRACT, INCLUDING GENERAL AND SUPPLEMENTARY CONDITIONS AND DIVISION 01
SPECIFICATION SECTIONS, APPLY TO THIS SECTION.
1.2 SUMMARY
A. SECTION INCLUDES:
1. FACTORY -FINISHED WOOD FLOORING.
1.3 SUBMITTALS
A. PRODUCT DATA: FOR EACH TYPE OF PRODUCT INDICATED.
B. SHOP DRAWINGS: FOR EACH TYPE OF FLOOR ASSEMBLY AND ACCESSORY. INCLUDE PLANS, ELEVATIONS, SECTIONS, DETAILS, AND
ATTACHMENTS TO OTHER WORK. INCLUDE EXPANSION PROVISIONS AND
TRIM DETAILS.
C. SAMPLES FOR INITIAL SELECTION: MANUFACTURER'S COLOR CHARTS SHOWING THE FULL RANGE OF COLORS AND FINISHES AVAILABLE
FOR WOOD FLOORING.
D. SAMPLES FOR VERIFICATION: FOR EACH TYPE OF WOOD FLOORING AND ACCESSORY, WITH STAIN COLOR AND FINISH REQUIRED,
APPROXIMATELY 12 INCHES LONG AND OF SAME THICKNESS AND MATERIAL INDICATED FOR THE WORK AND SHOWING THE FULL RANGE
OF NORMAL COLOR AND TEXTURE VARIATIONS EXPECTED.
1.4 QUALITY ASSURANCE
A. MANUFACTURER QUALIFICATIONS: A QUALIFIED MANUFACTURER THAT IS CERTIFIED FOR CHAIN OF CUSTODY BY AN FSC -ACCREDITED
CERTIFICATION BODY.
B. HARDWOOD FLOORING: COMPLY WITH NOFMA'S "OFFICIAL FLOORING GRADING RULES" FOR SPECIES, GRADE, AND CUT.
1. CERTIFICATION: PROVIDE FLOORING THAT CARRIES NOFMA GRADE STAMP ON EACH BUNDLE OR PIECE.
C. MAPLE FLOORING: COMPLY WITH APPLICABLE MFMA GRADING RULES FOR SPECIES, GRADE, AND CUT.
1. CERTIFICATION: PROVIDE FLOORING THAT CARRIES MFMA MARK ON EACH BUNDLE OR PIECE.
D. SOFTWOOD FLOORING: COMPLY WITH WCLIB NO. 17 GRADING RULES FOR SPECIES, GRADE, AND CUT.
E. BUILD MOCKUP OF TYPICAL FLOORING AREA AS SHOWN ON DRAWINGS.
1. TO SET QUALITY STANDARDS FOR SANDING AND APPLICATION OF FIELD FINISHES, PREPARE FINISH MOCKUP OF FLOOR AREA AS
SHOWN ON DRAWINGS.
2. APPROVAL OF MOCKUPS DOES NOT CONSTITUTE APPROVAL OF DEVIATIONS FROM THE CONTRACT DOCUMENTS CONTAINED IN
MOCKUPS UNLESS ARCHITECT SPECIFICALLY APPROVES SUCH DEVIATIONS IN WRITING.
3. APPROVED MOCKUPS MAY BECOME PART OF THE COMPLETED WORK IF UNDISTURBED AT TIME OF SUBSTANTIAL COMPLETION.
1.5 DELIVERY, STORAGE, AND HANDLING
A DELIVER WOOD FLOORING MATERIALS IN UNOPENED CARTONS OR BUNDLES.
B. PROTECT WOOD FLOORING FROM EXPOSURE TO MOISTURE. DO NOT DELIVER WOOD FLOORING UNTIL AFTER CONCRETE, MASONRY,.
PLASTER, CERAMIC TILE, AND SIMILAR WET WORK IS COMPLETE AND DRY.
C. STORE WOOD FLOORING MATERIALS IN A DRY, WARM, VENTILATED, WEATHERTIGHT LOCATION.
1.6 PROJECT CONDITIONS
A. CONDITIONING PERIOD BEGINS NOT LESS THAN SEVEN DAYS BEFORE WOOD FLOORING INSTALLATION, IS CONTINUOUS THROUGH
INSTALLATION, AND CONTINUES NOT LESS THAN SEVEN DAYS AFTER WOOD FLOORING INSTALLATION.
1. ENVIRONMENTAL CONDITIONING: MAINTAIN AN AMBIENT TEMPERATURE BETWEEN 65 AND 75 DEG F AND RELATIVE HUMIDITY
PLANNED FOR BUILDING OCCUPANTS IN SPACES TO RECEIVE WOOD FLOORING DURING THE CONDITIONING PERIOD.
2 WOOD FLOORING CONDITIONING: MOVE WOOD FLOORING INTOT ED
SPACES WHERE IT WILL BE ALL NO LATER THAN THE INS
BEGINNING OF THE CONDITIONING PERIOD.
a. DO NOT INSTALL FLOORING UNTIL IT ADJUSTS TO RELATIVE HUMIDITY OF, AND IS AT SAME TEMPERATURE AS, SPACE WHERE IT IS
TO BE INSTALLED.
b. OPEN SEALED PACKAGES TO ALLOW WOOD FLOORING TO ACCLIMATIZE T IMMEDIATELY N MOVING FLOORING INTO SPACES IN
I IA O
WHICH IT WILL BE INSTALLED.
B. AFTER CONDITIONING PERIOD, MAINTAIN RELATIVE HUMIDITY AND AMBIENT TEMPERATURE PLANNED FOR BUILDING OCCUPANTS.
C. INSTALL FACTORY -FINISHED WOOD FLOORING AFTER OTHER FINISHING OPERATIONS, INCLUDING PAINTING, HAVE BEEN COMPLETED.
1.7 EXTRA MATERIALS
A. FURNISH EXTRA MATERIALS DESCRIBED BELOW, BEFORE INSTALLATION BEGINS, THAT MATCH PRODUCTS INSTALLED AND THAT ARE
PACKAGED WITH PROTECTIVE COVERING FOR STORAGE AND IDENTIFIED WITH LABELS DESCRIBING CONTENTS.
1. WOOD FLOORING: EQUAL TO 10 PERCENT OF AMOUNT INSTALLED FOR EACH TYPE OF WOOD FLOORING INDICATED.
PART2- PRODUCTS
2.1 FINISHED WOOD FLOORING
A. CERTIFIED WOOD: PROVIDE WOOD FLOORING PRODUCED FROM WOOD OBTAINED FROM FORESTS CERTIFIED BY AN FSC -ACCREDITED
CERTIFICATION BODY TO COMPLY WITH FSC STD -01-001, "FSC PRINCIPLES AND CRITERIA FOR FOREST STEWARDSHIP."
B. SOLID -WOOD FLOORING: KILN DRIED TO 6 TO 9 PERCENT MAXIMUM MOISTURE CONTENT, TONGUE AND GROOVE AND END MATCHED, AND
WITH BACKS CHANNELED.
1. MANUFACTURERS: SUBJECT TO COMPLIANCE WITH REQUIREMENTS, PROVIDE PRODUCTS BY THE FOLLOWING:
2. BASIS -OF -DESIGN PRODUCT: SUBJECT TO COMPLIANCE WITH REQUIREMENTS, PROVIDE ASI HARDWOOD FLOORING- FLWCLO47:
a. ASI (ARCHITECTURAL SYSTEMS, INC.
3. SPECIES AND GRADE: WALNUT WITH CUSTOM COLOR.
4. THICKNESS: 1Y2INCH.
5. FACE WIDTH: 51NCHES
6. LENGTHS: RL- RANDOM -LENGTH STRIPS COMPLYING WITH APPLICABLE GRADING RULES.
7. FINISH: ALUMINUM OXIDE.
C. WOOD FILLER: COMPATIBLE WITH FINISH SYSTEM COMPONENTS AND RECOMMENDED BY FILLER AND FINISH MANUFACTURERS FOR USE
INDICATED. IF REQUIRED TO MATCH APPROVED SAMPLES, PROVIDE PIGMENTED FILLER.
2.2 SOUND CONTROL UNDERLAYMENT (IF APPLICABLE)
A. SOUND CONTROL UNDERLAYMENT: SOUND REDUCING UNDERLAYMENT CONSISTING OF IMPACT -ABSORBING MATERIALS. MINIMUM
IMPACT INSULATION CLASS (IIC) OF 50 WHEN TESTED ACCORDING TO ASTM E 492.
1. MATERIAL: RECYCLED RUBBER, OR WOOD FIBER MADE WITH BINDER CONTAINING NO UREA FORMALDEHYDE.
2. THICKNESS AS REQUIRED PER PROJECT, CONTRACTOR TO FIELD VERIFY PRIOR TO ORDERING OR INSTALLATION.
2.3 ACCESSORY MATERIALS (IF USED AND AS REQUIRED PER ANN TAYLOR/MANUFACTURER PER PROJECT) (ANN TAYLOR USING A
TRANSITION STRIP BETWEEN ALL FLOORING MATERIALS : SCHLUTER STRIP) VERIFY WITH ANN TAYLOR PRIOR TO ORDERING AND
INSTALLATION)
A. WOOD UNDERLAYMENT: (IF APPLICABLE) AS SPECIFIED IN DIVISION 06 SECTION "ROUGH CARPENTRY."
B. VAPOR RETARDER: (AS REQUIRED PER MANUFACTURER) ASTM D 4397
C. ASPHALT -SATURATED FELT: (AS REQUIRED PER MANUFACTURER) ASTM D 4869, TYPE 11.
D. WOOD FLOORING ADHESIVE: MASTIC RECOMMENDED BY FLOORING AND ADHESIVE MANUFACTURERS FOR APPLICATION INDICATED.
1. USE ADHESIVES THAT HAVE A VOC CONTENT OF NOT MORE THAN 100 G/L WHEN CALCULATED ACCORDING TO 40 CFR 59, SUBPART D
(EPA METHOD 24).
E. TROWELABLE LEVELING AND PATCHING COMPOUND (AS REQUIRED PER MANUFACTURER) : LATEX -MODIFIED, HYDRAULIC -CEMENT -BASED
FORMULATION APPROVED BY WOOD FLOORING MANUFACTURER.
F. FASTENERS: AS RECOMMENDED BY MANUFACTURER, BUT NOT LESS THAN THAT RECOMMENDED IN NWFA'S "INSTALLATION GUIDELINES:
WOOD FLOORING.
PART 3 - EXECUTION
3.1 EXAMINATION
A. EXAMINE SUBSTRATES, AREAS AND CONDITIONS, WITH INSTALLER PRESENT, FOR COMPLIANCE WITH REQUIREMENTS FOR MAXIMUM
MOISTURE CONTENT, INSTALLATION TOLERANCES, AND OTHER CONDITIONS AFFECTING PERFORMANCE OF WOOD FLOORING.
B. PROCEED WITH INSTALLATION ONLY AFTER UNSATISFACTORY CONDITIONS HAVE BEEN CORRECTED.
C. CONCRETE SLABS: VERIFY THAT CONCRETE SUBSTRATES ARE DRY ANDMOISTURE-VAPOR EMISSIONS ARE WITHIN ACCEPTABLE LEVELS
ACCORDING TO MANUFACTURER'S WRITTEN INSTRUCTIONS.
1. MOISTURE TESTING: PERFORM TESTS SO THAT EACH TEST AREA DOES NOT EXCEED 200 SQ. FT., AND PERFORM NO FEWER THAN
TWO TESTS IN EACH INSTALLATION AREA AND WITH TEST AREAS EVENLY SPACED IN INSTALLATION AREAS.
a. PERFORM ANHYDROUS CALCIUM CHLORIDE TEST PER ASTM F 1869, AS FOLLOWS:
1) PROCEED WITH INSTALLATION ONLY AFTER SUBSTRATES HAVE MAXIMUM MOISTURE -VAPOR -EMISSION RATE OF 3 LB OF
WATER/1000 SQ. FT. IN 24 HOURS.
b. PERFORM TESTS RECOMMENDED BY MANUFACTURER. PROCEED WITH INSTALLATION ONLY AFTER SUBSTRATES PASS TESTING.
3.2 PREPARATION (PREPARE IN ACCORDANCE WITH MANUFACTURER'S RECOMMENDATIONS)
A. CONCRETE SLABS: GRIND HIGH SPOTS AND FILL LOW SPOTS TO PRODUCE A MAXIMUM 3/164NCH DEVIATION IN ANY DIRECTION WITHIN 6
FT. WHEN CHECKED WITH A 10 -FOOT STRAIGHT EDGE.
1. USE TROWELABLE LEVELING AND PATCHING COMPOUNDS, ACCORDING TO MANUFACTURER'S WRITTEN INSTRUCTIONS, TO FILL
CRACKS, HOLES, AND DEPRESSIONS IN SUBSTRATES.
B. REMOVE COATINGS, INCLUDING CURING COMPOUNDS, AND OTHER SUBSTANCES ON SUBSTRATES THAT ARE INCOMPATIBLE WITH
INSTALLATION ADHESIVES AND THAT CONTAIN SOAP, WAX, OIL, OR SILICONE, USING MECHANICAL METHODS RECOMMENDED BY
MANUFACTURER. DO NOT USE SOLVENTS.
C. BROOM OR VACUUM CLEAN SUBSTRATES TO BE COVERED IMMEDIATELY BEFORE PRODUCT INSTALLATION. AFTER CLEANING, EXAMINE
SUBSTRATES FOR MOISTURE, ALKALINE SALTS, CARBONATION, OR DUST. PROCEED WITH INSTALLATION ONLY AFTER UNSATISFACTORY
CONDITIONS HAVE BEEN CORRECTED.
3.3 INSTALLATION
A. COMPLY WITH FLOORING MANUFACTURER'S WRITTEN INSTALLATION INSTRUCTIONS, BUT NOT LESS THAN APPLICABLE
RECOMMENDATIONS IN NWFA'S "INSTALLATION GUIDELINES: WOOD FLOORING.
B. WOOD SLEEPERS AND SUBFLOOR (IF APPLICABLE) : INSTALL ACCORDING TO REQUIREMENTS IN DIVISION 06 SECTION "ROUGH
CARPENTRY".
C. WOOD UNDERLAYMENT (IF APPLICABLE) : INSTALL ACCORDING TO REQUIREMENTS IN DIVISION 06 SECTION 'ROUGH CARPENTRY".
D. PROVIDE EXPANSION SPACE AT WALLS AND OTHER OBSTRUCTIONS AND TERMINATIONS OF FLOORING OF NOT LESS THAN 3/4 INCH, OR
PER MANUFACTURER'S RECOMMENDATIONS.
E. VAPOR RETARDER: COMPLY WITH NOFMA'S "INSTALLING HARDWOOD FLOORING" FOR VAPOR RETARDER INSTALLATION AND THE
FOLLOWING:
1. WOOD FLOORING NAILED TO WOOD SUBFLOOR: INSTALL FLOORING OVER A LAYER OF ASPHALT -SATURATED FELT.
2. WOOD FLOORING NAILED TO SLEEPERS OVER CONCRETE: INSTALL FLOORING OVER A LAYER OF POLYETHYLENE SHEET WITH EDGES
OVERLAPPED OVER SLEEPERS AND TURNED UP BEHIND BASEBOARDS.
3. WOOD FLOORING INSTALLED DIRECTLY ON CONCRETE: INSTALL A LAYER OF POLYETHYLENE SHEET ACCORDING TO FLOORING
MANUFACTURER'S WRITTEN INSTRUCTIONS.
F. SOUND CONTROL UNDERLAYMENT (IF APPLICABLE) : INSTALL OVER VAPOR RETARDER IN ACCORDANCE WITH MANUFACTURER'S
WRITTEN INSTRUCTIONS.
3.4 PROTECTION
A. PROTECT INSTALLED WOOD FLOORING DURING REMAINDER OF CONSTRUCTION PERIOD WITH COVERING OF HEAVY KRAFT PAPER OR
OTHER SUITABLE MATERIAL. DO NOT USE PLASTIC SHEET OR FILM THAT MIGHT CAUSE CONDENSATION.
1. DO NOT MOVE HEAVY AND SHARP OBJECTS DIRECTLY OVER KRAFT -'APER -COVERED WOOD FLOORING. PROTECT FLOORING WITH
PLYWOOD OR HARDBOARD PANELS TO PREVENT DAMAGE FROM STORING OR MOVING OBJECTS OVER FLOORING.
END OF SECTION 096400
SECTION 09680 - CARPET
PART 1 -GENERAL
1.01 SUMMARY OF WORK
A. THIS WORK OF THIS SECTION INCLUDES, BUT IS NOT NECESSARILY LIMITED TO, THE FOLLOWING:
1. CARPET
2. CUSHION
3. ACCESSORIES
1.02 QUALITY ASSURANCE
A. CARPET SURFACE BURNING CHARACTERISTICS: PROVIDE CARPET IDENTICAL TO THAT TESTED FOR THE FOLLOWING FIRE
PERFORMANCE CHARACTERISTICS, PER TEST METHOD INDICATED BELOW, BY UL OR OTHER TESTING AND INSPECTING
ORGANIZATIONS ACCEPTABLE TO AUTHORITIES HAVING JURISDICTION. IDENTIFY CARPET WITH APPROPRIATE MARKINGS
OF APPLICABLE TESTING AND INSPECTING ORGANIZATION.
1. TEST METHOD: DOC FF 1-70
2. RATING: PASS
B. CUSHION SURFACE BURNING CHARACTERISTICS: PROVIDE CARPET CUSHION IDENTICAL TO THAT TESTED FOR THE
FOLLOWING FIRE PERFORMANCE CHARACTERISTICS, PER TEST METHOD INDICATED BELOW, BY UL OR OTHER TESTING AND
INSPECTING ORGANIZATIONS ACCEPTABLE TO AUTHORITIES HAVING JURISDICTION. IDENTIFY CARPET CUSHION WITH
APPROPRIATE MARKINGS OF APPLICABLE TESTING AND INSPECTING ORGANIZATION.
1. TEST METHOD: DOC FF 1-70
2. RATING: PASS
3. TEST METHOD: ASTM E 84
4. FLAME SPREAD: 25 OR LESS
5. SMOKE DEVELOPED: 450 OR LESS
1.03 SUBMITTALS
A. PRODUCT DATA: FOR EACH TYPE OF CARPET MATERIAL AND INSTALLATION ACCESSORY REQUIRED, M
QUI ,SUB R
MANUFACTURER'S TECHNICAL DATA ON PHYSICAL CHARACTERISTICS, DURABILITY, RESISTANCE TO FADING AND FLAME
RESISTANCE CHARACTERISTICS.
B. SHOP DRAWINGS: SUBMIT SHOP DRAWINGS SHOWING LAYOUT AND SEAMING DIAGRAMS. INDICATE PILE OR PATTERN
DIRECTION AND LOCATIONS AND TYPES OF EDGE STRIPS. INDICATE COLUMNS, DOORWAYS, ENCLOSING WALLS OR
PARTITIONS, BUILT-IN CABINETS AND LOCATIONS WHERE CUTOUTS ARE REQUIRED IN THE CARPET. SHOW INSTALLATION
DETAILS AT SPECIAL CONDITIONS.
C. SAMPLES: SUBMIT, FOR VERIFICATION PURPOSES IN MANUFACTURER'S STANDARD SIZE, SAMPLES SHOWING FULL RANGE
OF COLOR, TEXTURE AND PATTERN VARIATIONS EXPECTED. PREPARE SAMPLES FROM SAME MATERIAL TO BE USED FOR
THE WORK. SUBMIT THE FOLLOWING:
1. 12" SQUARE SAMPLES OF EACH TYPE OF CARPET MATERIAL REQUIRED.
2. 12" LONG SAMPLES OF EACH TYPE OF EXPOSED EDGE STRIPPING AND ACCESSORY ITEM.
3. 6" SQUARE SAMPLES OF EACH TYPE OF CARPET CUSHION.
1.04 DELIVERY, STORAGE AND HANDLING
DELIVER MATERIALS TO PROJECT SITE IN ORIGINAL FACTORY WRAPPINGS AND CONTAINERS, LABELED WITH IDENTIFICATION
OF THE MANUFACTURER, BRAND NAME AND LOT NUMBER. STORE MATERIALS IN ORIGINAL UNDAMAGED PACKAGES AND
CONTAINERS, INSIDE WELL -VENTILATED AREA PROTECTED FROM WEATHER, MOISTURE, SOILAGE, EXTREME
TEMPERATURES AND HUMIDITY.
1.05 ENVIRONMENTAL CONDITIONS
LAY FLAT, BLOCKED, OFF GROUND. MAINTAIN MINIMUM TEMPERATURE OF 65OF AT LEAST THREE DAYS PRIOR TO AND
DURING INSTALLATION IN AREA WHERE MATERIALS ARE STORED.
1.06 EXTRA MATERIALS
DELIVER EXTRA MATERIALS TO OWNER. FURNISH EXTRA MATERIALS MATCHING PRODUCTS INSTALLED AS DESCRIBED BELOW,
PACKAGED WITH PROTECTIVE COVERING FOR STORAGE AND IDENTIFIED WITH LABELS DESCRIBING CONTENTS.
BEFORE INSTALLATION BEGINS, FURNISH QUANTITY OF FULL WIDTH FOR EACH TYPE OF MATERIAL EQUAL TO 5% OF AMOUNT
INSTALLED.
PART2-PRODUCTS
2.01 MANUFACTURERS
SUBJECT TO COMPLIANCE WITH REQUIREMENTS, MANUFACTURERS OFFERING PRODUCTS THAT MAY BE INCORPORATED IN
THE WORK INCLUDE, BUT ARE NOT LIMITED TO, THE FOLLOWING:
A. CARPET SCHEDULE:
SEE CONTRACT DRAWINGS FOR SPECIFICATIONS.
B. CARPET CUSHION:
1. CHRIS CRAFT INDUSTRIES, INC.
2. DIXIE MANUFACTURING COMPANY
3. E. R. CARPENTER COMPANY, INC.
4. GENERAL FELT INDUSTRIES, INC.
5. LUDLOW CARPET CUSHION
6. OLIN CORPORATION, OMALON CARPET FOUNDATION
7. SPONGE CUSHION, INC.
8. UNIROYAL, INC.
2.02CARPET CUSHION
TREATED FOR MILDEW RESISTANCE AND, IF APPLICABLE, WITH PERMANENT MOTHPROOFING; STERILIZED; BONDED TO
FINISHED TOP SURFACE APPROPRIATE FOR TYPE OF CUSHION AND COMPLYING WITH THE ADDITIONAL REQUIREMENTS AND
STANDARDS BELOW:
A. TYPE: "AUTHORITY," CHOICE #722, 24 OZ., 8.0 DENSITY
B. TRAFFIC DESIGNATION: 11- HEAVY
C. CUSHION ADHESIVES: PROVIDE MANUFACTURER'S RECOMMENDED MILDEW -RESISTANT ADHESIVE, PRODUCED EXPRESSLY
FOR USE WITH TYPE OF CARPET CUSHION AND SUBSTRATE INDICATED.
D. THICKNESS: 3/8"+ 1/32"
2.03 ACCESSORIES
A. TACKLESS CARPET STRIPPING: WATER-RESISTANT PLYWOOD IN STRIPS, 3/8" OR 9/32" THICK, AS REQUIRED TO MATCH
CUSHION THICKNESS; TWO (2) OR THREE (3) ROWS, AS INDICATED IN PARAGRAPH 3.02 BELOW, OF ANGULAR PINS
PROTRUDING FROM TOP, DESIGNED TO GRIP AND HOLD STRETCHED CARPET AT BACKING.
B. CARPET EDGE GUARD: ALUMINUM WITH FOLD -DOWN EDGE AND CONCEALED GRIPPER TEETH; MINIMUM 1-1Q" WIDE
PUNCHED ANCHORAGE FLANGE; MINIMUM 5/8" WIDE FOLD FLANGE. ANODIZED ALUMINUM FINISH, SMOOTH FINISH,
MANUFACTURER'S STANDARD COLORS.
C. CARPET EDGE GUARD: EXTRUDED OR MOLDED HEAVY DUTY VINYL OR RUBBER OF SIZE AND PROFILE INDICATED; MINIMUM
2" WIDE ANCHORAGE FLANGE; MANUFACTURER'S STANDARD COLORS.
D. SEAMING CEMENT: HOT -MELT ADHESIVE TAPE OR SIMILAR PRODUCT RECOMMENDED BY CARPET MANUFACTURER FOR
TAPING SEAMS AND BUTTING CUT EDGES AT BACKING TO FORM SECURE SEAMS AND TO PREVENT PILE LOSS AT SEAMS.
E. CARPET ADHESIVE: WATER RESISTANT AND NONSTAINING AS RECOMMENDED BY CARPET MANUFACTURER TO COMPLY
WITH FLAMMABILITY REQUIREMENTS FOR INSTALLED CARPET.
F. CUSHION ADHESIVE: MANUFACTURER'S RECOMMENDED MILDEW -RESISTANT ADHESIVE, PRODUCED EXPRESSLY FOR USE
WITH SELECTED CARPET CUSHION ON SUBSTRATE.
PART 3 - EXECUTION
3.01 PREPARATION
PATCH HOLES AND LEVEL TO A SMOOTH SURFACE. IF PREVIOUS FINISH CHEMICALLY STRIPPED, RESEAL CONCRETE. SEAL
POWDERY OR POROUS SURFACES WITH SEALER RECOMMENDED BY CARPET MANUFACTUREP,
3.02 INSTALLATION
A. COMPLY WITH MANUFACTURER'S RECOMMENDATIONS FOR SEAM LOCATIONS AND DIRECTION OF CARPET; MAINTAIN
UNIFORMITY OF CARPET DIRECTION AND LAY OF PILE. AT DOORWAYS, CENTER SEAMS UNDER DOOR IN CLOSED POSITION;
DO NOT PLACE SEAMS PERPENDICULAR TO DOOR FRAME, IN DIRECTION OF TRAFFIC THROUGH DOORWAY. DO NOT BRIDGE
BUILDING EXPANSION JOINTS WITH CONTINUOUS CARPET.
B. EXTEND CARPET UNDER REMOVABLE FLANGES AND FURNISHINGS AND INTO ALCOVES AND CLOSETS OF EACH SPACE.
C. PROVIDE CUTOUTS WHERE REQUIRED AND BIND CUT EDGES WHERE NOT CONCEALED BY PROTECTIVE EDGE GUARDS OR
OVERLAPPING FLANGES.
D. INSTALL CARPET EDGE GUARD WHERE EDGE OF CARPET IS EXPOSED; ANCHOR GUARDS TO SUBSTRATE.
E. INSTALL TACKLESS CARPET STRIPPING BY NAILING. LOCATE TO ENSURE CONCEALMENT OF CARPET EDGE BETWEEN
STRIPPING AND BASE OF WALL. LAY STRIP AT ENTIRE PERIMETER OF CARPETED SPACE, OBSTRUCTIONS AND CUTOUTS.
PROVIDE NARROW STRIPPING WITH TWO (2) ROWS OF PINS WHERE STRETCHED WIDTH OF CARPET IS 20' OR LESS;
STRIPPING WITH THREE (3) ROWS OF PINS WHERE CARPET WIDTH EXCEEDS 20'.
F. INSTALL CUSHION SEAMS AT 900 ANGLE WITH CARPET SEAMS. PLACE CUSHION FACE UP AS RECOMMENDED BY CUSHION
MANUFACTURER. APPLY MINIMUM 2" FABRIC -TYPE ADHESIVE TAPE ON CUSHION SEAMS. IN RAMPED FLOOR AREAS,
INCREASE ANCHORAGE OR ADHESIVE. BOND CARPET CUSHION TO SUBSTRATE.
G. INSTALL WITH PATTERN PARALLEL TO WALLS AND BORDERS.
H. INSTALL CARPET BY TRIMMING EDGES, BUTTING CUTS WITH SEAMING CEMENT AND TAPING AND/OR SEWING SEAMS TO
PROVIDE SUFFICIENT STRENGTH FOR STRETCHING AND CONTINUED STRESSES DURING LIFE OF CARPET.
I. STRETCH CARPET TO PROVIDE SMOOTH, RIPPLE -FREE, TAUT, TRIM EDGES; SECURE TO STRIPPING AND CONCEAL BEHIND
EDGE OF STRIPPING. USE POWER STRETCHER WHERE CARPET LENGTH IS GREATER THAN 20'.
J. FIT SECTIONS OF CARPET PRIOR TO APPLICATION OF ADHESIVE. TRIM EDGES AND BUTT CUTS WITH SEAMING CEMENT.
K. APPLY ADHESIVE UNIFORMLY TO SUBSTRATE IN ACCORDANCE WITH MANUFACTURER'S INSTRUCTIONS. BUTT EDGES
TIGHTLY TO FORM SEAMS WITHOUT GAPS. ROLL ENTIRE AREA LIGHTLY TO ELIMINATE AIR POCKETS AND TO ENSURE
UNIFORM BOND.
3.03CLEANING
A. REMOVE ADHESIVE FROM CARPET SURFACE WITH MANUFACTURER'S RECOMMENDED CLEANING AGENT.
B. REMOVE AND DISPOSE OF DEBRIS AND UNUSABLE SCRAPS. VACUUM WITH COMMERCIAL MACHINE WITH FACE -BEATER
ELEMENT. REMOVE SOIL. REPLACE CARPET WHERE SOIL CANNOT BE REMOVED. REMOVE PROTRUDING FACE YARN.
C. VACUUM CARPET.
3.04PROTECTION
PROVIDE FINAL PROTECTION AND MAINTAIN CONDITIONS, IN A MANNER ACCEPTABLE TO MANUFACTURER AND INSTALLER, TO
ENSURE CARPET IS NOT DAMAGED OR DETERIORATED AT TIME OF SUBSTANTIAL COMPLETION.
END OF SECTION 09680
SECTION 09900 - PAINTING
PART 1 - GENERAL
1.01 SUMMARY OF WORK
A. THE WORK OF THIS SECTION INCLUDES, BUT IS NOT NECESSARILY LIMITED TO, THE FOLLOWING:
1. PAINTING AND FINISHING OF INTERIOR EXPOSED ITEMS AND SURFACES THROUGHOUT THE PROJECT, EXCEPT AS OTHERWISE
INDICATED.
SURFACE PREPARATION, PRIMING AND COATS OF PAINT SPECIFIED ARE IN ADDITION TO SHOP -PRIMING AND
SURFACE TREATMENT SPECIFIED UNDER OTHER SECTIONS OF WORK.
2. "PAINT" AS USED HEREIN MEANS ALL COATING SYSTEM MATERIALS, INCLUDING PRIMERS, EMULSIONS, ENAMELS, STAINS,
SEALERS AND FILLERS AND OTHER APPLIED MATERIALS WHETHER USED AS PRIME, INTERMEDIATE OR FINISH COATS.
3. PAINT ALL EXPOSED SURFACES WHETHER OR NOT COLORS ARE DESIGNATED IN "SCHEDULES," EXCEPT WHERE NATURAL
FINISH OF MATERIAL IS SPECIFICALLY NOTED AS A SURFACE NOT TO BE PAINTED. WHERE ITEMS OR SURFACES ARE NOT
SPECIFICALLY MENTIONED, PAINT SAME AS ADJACENT SIMILAR MATERIALS OR AREAS. IF COLOR OR FINISH IS NOT
DESIGNATED, DESIGNER WILL SELECT THESE FROM STANDARD COLORS AVAILABLE FOR MATERIAL SYSTEMS SPECIFIED.
B. RELATED WORK SPECIFIED ELSEWHERE
1. SHOP PRIMING: UNLESS OTHERWISE SPECIFIED, SHOP PRIMING OF FERROUS METAL ITEMS IS INCLUDED UNDER VARIOUS
SECTIONS OF MISCELLANEOUS METAL, HOLLOW METAL WORK, ELEVATOR WORK AND SIMILAR ITEMS; ALSO, FOR FABRICATED
COMPONENTS SUCH AS ARCHITECTURAL WOODWORK AND SHOP -FABRICATED OR FACTORY -BUILT MECHANICAL AND
ELECTRICAL EQUIPMENT OR ACCESSORIES.
2. MECHANICAL AND ELECTRICAL WORK: PAINTING OF MECHANICAL AND ELECTRICAL WORK IS SPECIFIED IN DIVISIONS 15 AND
16 RESPECTIVELY.
C. ITEMS NOT TO BE PAINTED
1. PRE -FINISHED ITEMS: UNLESS OTHERWISE INDICATED, DO NOT INCLUDE PAINTING WHEN FACTORY -FINISHING OR INSTALLER -
FINISHING IS SPECIFIED FOR SUCH ITEM AS (BUT NOT NECESSARILY LIMITED TO) ARCHITECTURAL WOODWORK, WOOD
FLOORING WORK, ELEVATOR EQUIPMENT AND FINISHED MECHANICAL AND ELECTRICAL EQUIPMENT INCLUDING LIGHT
FIXTURES, SWITCHGEAR AND DISTRIBUTION CABINETS.
2. CONCEALED SURFACES: UNLESS OTHERWISE INDICATED, PAINTING IS NOT REQUIRED ON SURFACES SUCH AS WALLS OR
CEILINGS IN CONCEALED AREAS AND GENERALLY INACCESSIBLE AREAS, PIPE SPACES AND DUCT SHAFTS.
3. FINISHED METAL SURFACES: METAL SURFACES OF ANODIZED ALUMINUM, BRASS, CHROMIUM PLATE AND SIMILARLY FINISHED
MATERIALS WILL NOT REQUIRE FINISH PAINTING.
4. OPERATING PARTS AND NAMEPLATES: MOVING PARTS OF OPERATING UNITS, MECHANICAL AND ELECTRICAL PARTS, SUCH
AS VALVE AND DAMPER OPERATORS AND SENSING DEVICES, WILL NOT REQUIRE FINISH PAINTING, UNLESS OTHERWISE
INDICATED.
5. DO NOT PAINT OVER ANY CODE -REQUIRED LABELS, SUCH AS UNDERWRITERS' LABORATORIES AND FACTORY MUTUAL, OR
ANY EQUIPMENT Q T IDENTIFICATION PERFORMANCE RATING, NAME OR NOMENCLATURE PLATES.
1.02 QUALITY ASSURANCE
INSTALLER SHALL BE A FIRM WITH NOT LESS THAN TEN (10) YEARS' SUCCESSFUL EXPERIENCE IN APPLYING COATINGS AND
FINISHES OF THE TYPE REQUIRED ON PROJECTS OF SIMILAR TYPE AND QUALITY LEVEL AS THIS PROJECT.
1.03 SUBMITTALS
A. PRODUCT DATA: SUBMIT MANUFACTURER'S TECHNICAL INFORMATION INCLUDING PAINT LABEL ANALYSIS AND APPLICATION
INSTRUCTIONS FOR EACH MATERIAL PROPOSED FOR USE. INCLUDE GLOSS RATINGS FOR EACH COLOR AND FINISH
REQUIRED.
B. SAMPLES: SUBMIT SAMPLES FOR DESIGNER'S REVIEW OF COLOR AND TEXTURE ONLY. PROVIDE A LISTING OF MATERIALS
AND APPLICATIONS FOR EACH COAT OF EACH FINISH SAMPLE. SAMPLES SHALL BE STEP-DOWN TYPE ON WHICH EACH
SUCCESSIVE COAT OF PAINT IS EXPOSED THE SAME AMOUNT AND TINTED SLIGHTLY DIFFERENT THAN THE PRECEDING AND
FOLLOWING COATS; IDENTIFY EACH COAT BY NAME AND TYPE.
1. ON 12" X 12" GYPSUM WALLBOARD, PROVIDE SAMPLES OF EACH COLOR, GLOSS AND MATERIAL, WITH TEXTURE TO SIMULATE
ACTUAL CONDITIONS. RESUBMIT SAMPLES AS REQUESTED BY DESIGNER UNTIL ACCEPTABLE SHEEN, COLOR AND TEXTURE
ARE ACHIEVED.
2. ON ACTUAL WOOD SURFACES, PROVIDE 4" X 8" SAMPLES OF EACH WOOD FINISH AND COLOR REQUIRED. LABEL AND IDENTIFY
EACH AS TO LOCATION AND APPLICATION.
C. DETAILED PAINTING SCHEDULE: SUBMIT A DETAILED PAINTING SCHEDULE FOR REVIEW BY THE DESIGNER. PREPARE THIS
SCHEDULE ON
THE BASIS OF THE SURFACES, TYPES OF PAINT MATERIALS AND NUMBER OF COATS REQUIRED. LIST THE
BRAND NAME OF THE PRODUCT OF THE MANUFACTURER PROPOSED FOR EACH USE.
D. SUBMIT LIST OF PREVIOUS PROJECTS OF INSTALLER FOR REVIEW BY DESIGNER TO SHOW COMPLIANCE WITH REQUIREMENTS
OF PARAGRAPH 1.02-A.
1.04 MOCK-UP
ON ACTUAL WALL
SURFACES AND OTHER INTERIOR BUILDING COMPONENTS, DUPLICATE PAINTED FINISHES OF PREPARED
SAMPLES. ON AT LEAST 500 FT2 OF SURFACE AS DIRECTED, PROVIDE FULL -COAT FINISH SAMPLES UNTIL REQUIRED SHEEN,
COLOR AND TEXTURE ARE OBTAINED; SIMULATE FINISHED LIGHTING CONDITIONS FOR REVIEW OF IN-PLACE WORK.
1.05 DELIVERY, STORAGE AND HANDLING
A. DELIVER PAINT MATERIALS TO THE JOB SITE IN ORIGINAL CONTAINERS AND PACKAGES, BEARING THE MANUFACTURER'S
LABELS, INDICATING NAME, TYPE AND BRAND. UNLESS OTHERWISE DIRECTED BY THE DESIGNER, DELIVER PAINTS
READY -MIXED. ORDER IN ADVANCE IN LARGE ENOUGH QUANTITIES AND IN AMPLE TIME TO FACILITATE THE WORK.
B. STORE MATERIALS AND EQUIPMENT IN A DESIGNATED STORAGE SPACE ON THE SITE. KEEP STORAGE SPACE NEAT, CLEAN
AND ACCESSIBLE AT ALL TIMES. PROTECT FLOORS FROM PAINT SPILLAGE.
1.06 ENVIRONMENTAL CONDITIONS
DO NOT PAINT WHEN THE AIR IS DUST -LADEN NOR WHEN WEATHER AND TEMPERATURE CONDITIONS ARE UNSUITABLE.
MAINTAIN TEMPERATURES WITHIN THE BUILDING AT A MINIMUM OF 60OF DURING THE PAINTING AND DRYING PERIODS.
COMPLY WITH MANUFACTURER'S RECOMMENDATIONS WHEN THEY ARE MORE STRINGENT WITH RESPECT TO APPLICATION
TEMPERATURES.
1.07 PROTECTION
A. PLACE PAINT OR SOLVENT -SOAKED RAGS, WASTE OR OTHER MATERIALS WHICH MIGHT CONSTITUTE A FIRE HAZARD IN METAL
CONTAINERS AND REMOVE FROM PREMISES AT THE CLOSE OF EACH DAY'S WORK. TAKE EVERY PRECAUTION TO AVOID
DAMAGE BY FIRE.
B. PROVIDE SUITABLE COVERINGS TO PROTECT SURFACES NOT REQUIRING PAINTING.
C. REMOVE OR PROTECT ITEMS SUCH AS HARDWARE, HARDWARE ACCESSORIES, PLATES, LIGHTING FIXTURES AND SIMILAR
ITEMS PLACED PRIOR TO PAINTING. REPOSITION OR REMOVE PROTECTION UPON COMPLETION OF EACH SPACE. HAVE
EQUIPMENT DISCONNECTED ADJACENT TO WALLS BY WORKMEN SKILLED IN THESE TRADES TO PERMIT PAINTING OF WALL
SURFACES; REPLACE AND RECONNECT AFTER COMPLETION OF PAINTING.
D. MAINTAIN WRAPPINGS OR OTHER FACTORY -APPLIED PROTECTION FURNISHED WITH FINISH HARDWARE OR OTHER ITEMS
PROVIDED BY OTHER TRADES AND INSTALLED IN AREAS WHERE PAINTING IS REQUIRED, AND IF DISPLACED OR REMOVED,
REPLACE FOR THE DURATION OF PAINTING WORK.
PART 2 -PRODUCTS
2.01 MANUFACTURERS
EXCEPT AS OTHERWISE INDICATED, PAINT SYSTEMS ARE SPECIFIED USING A GENERIC DESCRIPTION AND A SPECIFIC
PRODUCT OF BENJAMIN MOORE & COMPANY; EQUIVALENT PRODUCTS OF THE FOLLOWING MANUFACTURERS WILL BE
ACCEPTABLE AT THE SOLE JUDGEMENT OF THE DESIGNER.
A. GLIDDEN COATINGS AND RESINS
B. PPG INDUSTRIES
C. PRATT AND LAMBERT
D. SHERWIN WILLIAMS COMPANY
2.02 COLORS AND FINISHES
A. ON THE DRAWINGS, THE DESIGNATIONS INDICATE THE FOLLOWING PAINTS:
SEE CONTRACT DRAWINGS FOR SPECIFICATIONS.
B. COLOR PIGMENTS: PURE, NON -FADING, APPLICABLE TYPES TO SUIT SUBSTRATES AND SERVICE INDICATED.
LEAD CONTENT IN PIGMENT, IF ANY, IS LIMITED TO CONTAIN NOT MORE THAN 0.5% LEAD, AS LEAD METAL BASED ON THE
TOTAL NON-VOLATILE (DRY -FILM) OF PAINT BY WEIGHT.
C. GLOSS RATINGS: SPECULAR GLOSS OF FINISHED SURFACES SHALL BE WITHIN THE FOLLOWING RANGES WHEN MEASURED
AT 600 IN ACCORDANCE WITH ASTM D523.
GLOSS UNITS DEGREE OF GLOSS
FLAT BELOW 5
EGGSHELL 5 TO 15
SEMI -GLOSS 50 TO 60
D. PAINT COORDINATION: PROVIDE FINISH COATS WHICH ARE COMPATIBLE WITH PRIMER PAINTS USED. REVIEW OTHER
SECTIONS OF THESE SPECIFICATIONS IN WHICH PRIMER PAINTS ARE TO BE PROVIDED TO ENSURE COMPATIBILITY OF TOTAL
COATINGS SYSTEM FOR VARIOUS SUBSTRATES. UPON REQUEST FROM OTHER TRADES, FURNISH INFORMATION ON
CHARACTERISTICS OF FINISH MATERIALS PROPOSED FOR USE, TO ENSURE THAT COMPATIBLE PRIMER COATS ARE USED.
PROVIDE BARRIER COATS OVER INCOMPATIBLE PRIMERS OR REMOVE AND RE -PRIME, AS REQUIRED. NOTIFY DESIGNER IN
WRITING OF ANY ANTICIPATED PROBLEMS USING SPECIFIED COATING SYSTEMS WITH SUBSTRATES PRIMED BY OTHERS.
2.03 MATERIAL QUALITY
A. PROVIDE BEST QUALITY GRADE OF VARIOUS TYPES OF COATINGS AS REGULARLY MANUFACTURED BY ACCEPTABLE PAINT
MATERIALS MANUFACTURERS. MATERIALS NOT DISPLAYING MANUFACTURER'S IDENTIFICATION AS A STANDARD,
BEST -GRADE PRODUCT WILL NOT BE ACCEPTABLE.
B. PROVIDE UNDERCOAT PAINT PRODUCED BY SAME MANUFACTURER AS FINISH COATS. USE ONLY THINNERS APPROVED BY
PAINT MANUFACTURER AND USE ONLY WITHIN RECOMMENDED LIMITS.
C. WHERE INDICATED AND IN LOCATIONS WHERE AMBIENT TEMPERATURE- HUMIDITY CONDITIONS ENCOURAGE THE READY
FORMATION OF MILDEW, USE PAINTS WITH ADDITIONAL MILDEW INHIBITIVE AGENT INCORPORATED DURING THE
MANUFACTURING PROCESS, OF TYPE AND IN CONCENTRATION RECOMMENDED BY THE PAINT MANUFACTURER TO
WITHSTAND SUCH MILDEW FORMATION.
2.04 INTERIOR PAINT SYSTEMS
A. PROVIDE THE FOLLOWING PAINT SYSTEMS FOR VARIOUS SUBSTRATES AS INDICATED (PER FINISH SCHEDULE).
B. PAINTED WOOD: SEMI -GLOSS FINISH
1ST COAT INTERIOR ENAMEL UNDERCOAT
MOORE'S ALKYD ENAMEL UNDERBODY
2ND AND 3RD COATS ODORLESS INTERIOR SEMI -GLOSS ENAMEL
MOORE'S ALKYD DULAMEL ENAMEL
C. GYPSUM BOARD WALLS: EGGSHELL FINISH
1ST COAT INTERIOR LATEX -BASE PRIMER COAT
MOORE'S LATEX QUICK -DRY PRIME SEAL
2ND AND 3RD COATS INTERIOR EGGSHELL LATEX -BASE PAINT
MOORE'S LATEX REGAL AQUAVELVET
D. DRYWALL CEILINGS: FLAT FINISH
1ST COAT INTERIOR LATEX -BASE PRIMER COAT
MOORE's LATEX QUICK -DRY PRIME SEAL
2ND AND 3RD COATS INTERIOR FLAT LATEX -BASE PAINT
MOORE'S REGAL WALL SATIN
E. CONCRETE CEILINGS AND EXTERIOR WALLS: FLAT FINISH
1ST COAT EXTERIOR ALKYD OIL BASE PRIMER COAT
MOORE'S LATEX QUICK -DRY PRIME SEAL
2ND AND 3RD COATS EXTERIOR FLAT LATEX -BASE PAINT
MOORE'S REGAL WALL SATIN
F. HOLLOW METAL DOORS, FRAMES AND CONVECTORS: SEMI -GLOSS FINISH
1ST COAT BASE PRIMER
IRON -CLAD RETARDO
RUST INHIBITIVE PRIMER
2ND COAT INTERIOR ENAMEL UNDERCOAT
MOORE'S ALKYD ENAMEL UNDERBODY
3RD COAT ODORLESS INTERIOR SEMI -GLOSS ENAMEL
MOORE's ALKYD DULAMEL ENAMEL
" NOTE: ALL EXTERIOR WALLS AND/OR CONCRETE SLAB CEILINGS WHICH ARE TO BE PAINTED ARE TO BE SCRAPED,
CHEMICALLY WASHED, AND PAINTED PER THE SCHEDULE ABOVE.
PART 3 -EXECUTION
3.01 INSPECTION
A. EXAMINE AREAS AND CONDITIONS UNDER WHICH PAINTING WORK IS TO BE APPLIED FOR CONDITIONS DETRIMENTAL TO
PROPER AND TIMELY COMPLETION OF WORK. DO NOT PROCEED WITH WORK UNTIL UNSATISFACTORY CONDITIONS HAVE
BEEN CORRECTED.
B. STARTING OF PAINTING WORK WILL BE CONSTRUED AS ACCEPTANCE OF SURFACES AND CONDITIONS WITHIN ANY
PARTICULAR AREA.
C. DO NOT PAINT OVER DIRT, RUST, SCALE, GREASE, MOISTURE, SCUFFED SURFACES OR CONDITIONS OTHERWISE
DETRIMENTAL TO THE FORMATION OF A DURABLE PAINT FILM.
3.02 SURFACE PREPARATION
A. PERFORM PREPARATION AND CLEANING PROCEDURES IN ACCORDANCE WITH PAINT MANUFACTURER'S INSTRUCTIONS AND
AS HEREIN SPECIFIED, FOR EACH PARTICULAR SUBSTRATE CONDITION.
B. REMOVE HARDWARE, HARDWARE ACCESSORIES, MACHINED SURFACES, PLATES, LIGHTING FIXTURES AND SIMILAR ITEMS IN
PLACE AND NOT TO BE FINISH -PAINTED OR PROVIDE SURFACE -APPLIED PROTECTION PRIOR TO SURFACE PREPARATION AND
PAINTING OPERATIONS. REMOVE, IF NECESSARY, FOR COMPLETE PAINTING OF ITEMS AND ADJACENT SURFACES.
FOLLOWING COMPLETION OF PAINTING OF EACH SPACE OR AREA, REINSTALL REMOVED ITEMS.
C. CLEAN SURFACES TO BE PAINTED BEFORE APPLYING PAINT OR SURFACE TREATMENTS. REMOVE OIL AND GREASE PRIOR TO
MECHANICAL CLEANING. SCHEDULE CLEANING AND PAINTING SO THAT CONTAMINANTS
FROM CLEANING PROCESS WILL NOT FALL ONTO WET, NEWLY PAINTED SURFACES.
D. WOOD
1. CLEAN WOOD SURFACES TO BE PAINTED OF DIRT, OIL OR OTHER FOREIGN SUBSTANCES WITH SCRAPERS, MINERAL SPIRITS
AND SANDPAPER, AS REQUIRED. SANDPAPER SMOOTH THOSE FINISHED SURFACES EXPOSED TO VIEW AND DUST OFF.
SCRAPE AND CLEAN SMALL, DRY, SEASONED KNOTS AND APPLY A THIN COAT OF WHITE SHELLAC OR OTHER RECOMMENDED
KNOT SEALER BEFORE APPLICATION OF PRIMING COAT. AFTER PRIMING, FILL HOLES AND IMPERFECTIONS IN FINISH
SURFACES WITH PUTTY OR PLASTIC WOOD FILLER. SANDPAPER SMOOTH WHEN DRIED.
2. PRIME, STAIN OR SEAL WOOD REQUIRED TO BE JOB -PAINTED IMMEDIATELY UPON DELIVERY TO JOB. PRIME EDGES, ENDS,
FACES, UNDERSIDES AND BACKSIDES OF SUCH WOOD.
E. HOLLOW METAL DOORS AND FRAMES
1. CLEAN FERROUS SURFACES, WHICH ARE NOT GALVANIZED OR SHOP -COATED OF OIL, GREASE, DIRT, LOOSE MILL SCALE AND
OTHER FOREIGN SUBSTANCES BY SOLVENT OR MECHANICAL CLEANING.
2. TOUCH-UP SHOP -APPLIED PRIME COATS WHEREVER DAMAGED OR BARE, AS REQUIRED BY OTHER SECTIONS OF THESE
SPECIFICATIONS. CLEAN AND TOUCH-UP WITH THE SAME TYPE OF SHOP PRIMER.
F. GYPSUM DRYWALL: REPAIR MINOR CRACKS AND HOLES WITH FINISHING COMPOUND AND SAND SMOOTH AFTER DRYING.
3.03 MATERIALS PREPARATION
A. MIX AND PREPARE PAINTING MATERIALS IN ACCORDANCE WITH THE MANUFACTURER'S DIRECTIONS.
B. STORE MATERIALS NOT IN ACTUAL USE IN TIGHTLY COVERED CONTAINERS. MAINTAIN CONTAINERS USED IN STORAGE,
MIXING AND APPLICATION OF PAINT IN A CLEAN CONDITION, FREE OF FOREIGN MATERIALS AND RESIDUE.
C. STIR MATERIALS BEFORE APPLICATION TO PRODUCE A MIXTURE OF UNIFORM DENSITY AND STIR AS REQUIRED DURING
APPLICATION. DO NOT STIR SURFACE FILM INTO MATERIAL. REMOVE FILM AND, IF NECESSARY, STRAIN MATERIAL BEFORE
USING.
3.04 APPLICATION
A. GENERAL
1. APPLY PAINT IN ACCORDANCE WITH MANUFACTURER'S DIRECTIONS. USE APPLICATORS AND TECHNIQUES BEST SUITED FOR
SUBSTRATE AND TYPE OF MATERIAL BEING APPLIED.
2. APPLY ADDITIONAL COATS WHEN UNDERCOATS, STAINS OR OTHER CONDITIONS SHOW THROUGH FINAL COAT OF PAINT,
UNTIL PAINT FILM IS OF UNIFORM FINISH, COLOR AND APPEARANCE. GIVE SPECIAL ATTENTION TO ENSURE THAT SURFACES,
INCLUDING EDGES, CORNERS, CREVICES, WELDS AND EXPOSED FASTENERS RECEIVE A DRY FILM THICKNESS EQUIVALENT
TO THAT OF FLAT SURFACES.
3. PAINT SURFACES BEHIND MOVABLE EQUIPMENT AND FURNITURE SAME AS SIMILARLY EXPOSED SURFACES. PAINT SURFACES
BEHIND PERMANENTLY FIXED EQUIPMENT OR FURNITURE WITH PRIME COAT ONLY BEFORE FINAL INSTALLATION OF
EQUIPMENT.
4. PAINT INTERIOR SURFACES OF DUCTS, WHERE VISIBLE THROUGH REGISTERS OR GRILLES, WITH A FLAT, NON -SPECULAR
BLACK PAINT.
5. PAINT BACK SIDES OF ACCESS PANELS AND REMOVABLE OR HINGED COVERS TO MATCH EXPOSED SURFACES.
6. SAND LIGHTLY BETWEEN EACH SUCCEEDING ENAMEL COAT.
7. OMIT FIRST COAT (PRIMER) ON METAL SURFACES WHICH HAVE BEEN SHOP -PRIMED AND TOUCH-UP PAINTED, UNLESS
OTHERWISE INDICATED.
B. SCHEDULING PAINTING
1. APPLY FIRST -COAT MATERIAL TO SURFACES THAT HAVE BEEN CLEANED, PRE-TREATED OR OTHERWISE PREPARED FOR
PAINTING AS SOON AS PRACTICAL AFTER PREPARATION AND BEFORE SUBSEQUENT SURFACE DETERIORATION.
2. ALLOW SUFFICIENT TIME BETWEEN SUCCESSIVE COATINGS TO PERMIT PROPER DRYING. DO NOT RE -COAT UNTIL PAINT HAS
DRIED TO WHERE IT FEELS FIRM, DOES NOT DEFORM OR FEEL STICKY UNDER MODERATE THUMB PRESSURE AND
APPLICATION OF ANOTHER COAT OF PAINT WILL NOT CAUSE LIFTING OR LOSS OF ADHESION OF THE UNDERCOAT.
C. MINIMUM COATING THICKNESS: APPLY MATERIALS AT NOT LESS THAN MANUFACTURER'S RECOMMENDED SPREADING RATE,
TO ESTABLISH A TOTAL DRY FILM THICKNESS AS INDICATED OR, IF NOT INDICATED, AS RECOMMENDED BY COATING
MANUFACTURER.
D. PRIMER COATS
1. APPLY PRIMER COAT OF MATERIAL WHICH IS REQUIRED TO BE PAINTED OR FINISHED AND WHICH HAS NOT BEEN PRIME
COATED BY OTHERS.
2. RE -COAT PRIMED AND SEALED SURFACES WHERE THERE IS EVIDENCE OF SUCTION SPOTS OR UNSEALED AREAS IN FIRST
COAT, TO ENSURE A FINISH COAT WITH NO BURN -THROUGH OR OTHER DEFECTS DUE TO INSUFFICIENT SEALING.
E. PIGMENTED (OPAQUE) FINISHES: COMPLETELY COVER TO PROVIDE AN OPAQUE, SMOOTH SURFACE OF UNIFORM FINISH,
COLOR, APPEARANCE AND COVERAGE. CLOUDINESS, SPOTTING, HOLIDAYS, LAPS, BRUSH MARKS, RUNS, SAGS, ROPINESS
OR OTHER SURFACE IMPERFECTIONS WILL NOT BE ACCEPTABLE.
F. COMPLETED WORK: MATCH APPROVED SAMPLES FOR COLOR, TEXTURE AND COVERAGE. REMOVE, REFINISH OR REPAINT
WORK NOT IN COMPLIANCE WITH SPECIFIED REQUIREMENTS.
3.05 CLEAN-UP AND PROTECTION
A. CLEAN-UP
1. DURING PROGRESS OF WORK, REMOVE FROM SITE DISCARDED PAINT MATERIALS, RUBBISH, CANS AND RAGS AT END OF
EACH WORK DAY.
2. UPON COMPLETION OF PAINTING WORK, CLEAN WINDOW GLASS AND OTHER PAINT -SPATTERED SURFACES. REMOVE
SPATTERED PAINT BY PROPER METHODS OF WASHING AND SCRAPING, USING CARE NOT TO SCRATCH OR OTHERWISE
DAMAGE FINISHED SURFACES.
B. PROTECTION
1. PROTECT WORK OF OTHER TRADES, WHETHER TO BE PAINTED OR NOT, AGAINST DAMAGE BY PAINTING AND FINISHING
WORK. CORRECT ANY DAMAGE BY CLEANING, REPAIRING OR REPLACING AND REPAINTING, AS ACCEPTABLE TO DESIGNER.
2. PROVIDE "WET PAINT" SIGNS, AS REQUIRED TO INDICATE NEWLY -PAINTED FINISHES. REMOVE TEMPORARY PROTECTIVE
WRAPPINGS PROVIDED BY OTHERS FOR PROTECTION OF THEIR WORK AFTER COMPLETION OF PAINTING OPERATIONS.
3. AT THE COMPLETION OF WORK OF OTHER TRADES, TOUCH-UP AND RESTORE ALL DAMAGED OR DEFACED PAINTED
SURFACES.
END OF SECTION 09900
SECTION 10800 -TOILET ACCESSORIES
PART 1 - GENERAL
1.01 SUMMARY OF WORK
A. THE WORK OF THIS SECTION INCLUDES, BUT IS NOT NECESSARILY LIMITED TO, THE FOLLOWING:
TOILET ACCESSORIES
1.02 QUALITY ASSURANCE
A. ACCESSORY LOCATIONS: COORDINATE ACCESSORY LOCATIONS WITH OTHER WORKS TO AVOID INTERFERENCE AND TO
ENSURE PROPER OPERATION AND SERVICING OF ACCESSORY UNITS.
B. PRODUCTS: PROVIDE PRODUCTS OF SAME MANUFACTURER FOR EACH TYPE OF ACCESSORY UNIT.
1.03 SUBMITTALS
A. PRODUCT DATA: SUBMIT MANUFACTURER'S TECHNICAL DATA AND INSTALLATION INSTRUCTIONS FOR EACH ACCESSORY.
B. SAMPLES: IF REQUIRED, SUBMIT FULL-SIZE SAMPLES OF UNITS TO
Q DESIGNER FOR REVIEW OF DESIGN AND OPERATION.
ACCEPTABLE SAMPLES WILL BE RETURNED AND MAY BE USED IN THE WORK.
C. SETTING DRAWINGS: PROVIDE SETTING DRAWINGS, TEMPLATES, INSTRUCTIONS AND DIRECTIONS FOR INSTALLATION OF
ANCHORAGE DEVICES IN OTHER WORK.
PART2-PRODUCTS
2.01 MANUFACTURERS/TYPE
DRAWINGS AND SPECIFICATIONS ARE BASED UPON THE PARTICULAR PRODUCTS OF THE MANUFACTURERS INDICATED.
EQUAL PRODUCTS OF OTHER MANUFACTURERS WILL BE ACCEPTABLE PROVIDED THEY COMPLY WITH THE INDICATED
REQUIREMENTS. SUBMIT INFORMATION ON ALTERNATE PRODUCTS TO THE DESIGNER FOR APPROVAL.
2.02 MATERIALS - GENERAL
A. STAINLESS STEEL: AISI TYPE 302/304 WITH POLISHED NO.4 FINISH, 22 GAUGE MINIMUM, UNLESS OTHER INDICATED.
B. BRASS: LEADED AND UNLEADED, FLAT PRODUCTS, FS QQ-B-613; RODS, SHAPES, FORGINGS AND FLAT PRODUCTS WITH
FINISHED EDGES, FS 00-13S26.
C. CHROMIUM PLATING: NICKEL AND CHROMIUM ELECTRO -DEPOSITED ON BASE METAL, ASTM B456, TYPE SC2.
D. GALVANIZED STEEL MOUNTING DEVICES: ASTM A386, HOT -DIP GALVANIZED AFTER FABRICATION.
E. FASTENERS: SCREWS, BOLTS AND OTHER DEVICES OF SAME MATERIAL AS ACCESSORY UNIT OR OF GALVANIZED STEEL
WHERE CONCEALED.
2.03 FABRICATION
A. GENERAL: STAMPED NAMES OR LABELS ON EXPOSED FACES OF ACCESSORY UNITS ARE NOT PERMITTED, UNOBTRUSIVE
LABELS ON SURFACES NOT EXPOSED TO VIEW ARE ACCEPTABLE.
B. SURFACE -MOUNTED TOILET ACCESSORIES: EXCEPT WHERE OTHERWISE INDICATED, FABRICATE UNITS WITH TIGHT SEAMS
AND JOINTS EXPOSED, EDGES ROLLED. PROVIDE CONCEALED ANCHORAGE WHEREVER POSSIBLE.
C. RECESSED TOILET ACCESSORIES: EXCEPT WHERE OTHERWISE INDICATED, FABRICATE UNITS OF ALL WELDED
CONSTRUCTION WITHOUT MITERED CORNERS. HANG DOORS AND ACCESS PANELS WITH FULL-LENGTH STAINLESS STEEL
PIANO HINGE. PROVIDE ANCHORAGE WHICH IS FULLY CONCEALED WHEN UNIT IS CLOSED.
2.04 SCHEDULE OF ACCESSORIES
SEE CONTRACT DRAWINGS FOR SPECIFICATIONS.
PART 3 - EXECUTION
3.01 INSTALLATION
INSTALL ACCESSORY UNITS IN ACCORDANCE WITH MANUFACTURERS' INSTRUCTIONS, USING FASTENERS WHICH ARE
APPROPRIATE TO SUBSTRATE AND RECOMMENDED BY MANUFACTURER OF UNIT. INSTALL UNITS PLUMB AND LEVEL, FIRMLY
ANCHORED IN LOCATIONS AND AT HEIGHT INDICATED.
3.02 ADJUSTMENT AND CLEANING
A. ADJUST ACCESSORIES FOR PROPER OPERATION AND VERIFY THAT MECHANISMS FUNCTION SMOOTHLY. REPLACE
DAMAGED OR DEFECTIVE ITEMS.
B. CLEAN AND POLISH ALL EXPOSED SURFACES AFTER REMOVING LABELS AND PROTECTIVE COATINGS.
END OF SECTION 10800
SECTION 11450 - PANTRY EQUIPMENT
PART 1 -GENERAL
1.01 SUMMARY OF WORK
A. THE WORK OF THIS SECTION INCLUDES, BUT IS NOT LIMITED TO, THE FOLLOWING:
1. REFRIGERATOR
2. MICROWAVE
B. RELATED WORK SPECIFIED ELSEWHERE
ELECTRICAL SERVICES AND CONNECTIONS - SEE DIVISION 16.
1.02 QUALITY ASSURANCE
VERIFY EXISTING CONDITIONS INCLUDING SIZES AND TYPES OF CONNECTIONS NECESSARY FOR PROPER RELOCATION OF
EXISTING KITCHEN EQUIPMENT.
1.03 SUBMITTALS
A. PRODUCT DATA: SUBMIT MANUFACTURER'S SPECIFICATIONS AND INSTALLATION INSTRUCTIONS AS WELL AS OPERATING
AND MAINTENANCE INSTRUCTIONS.
B. WARRANTY: SUBMIT MANUFACTURER'S STANDARD WRITTEN WARRANTY FOR EACH ITEM OF EQUIPMENT.
1.04 DELIVERY HANDLING AND STORAGE
PART 2 -PRODUCTS
2.01 SEE DRAWINGS FOR PANTRY SPECIFICATION
PART 3 - EXECUTION
3.01 INSTALLATION
A. COMPLY WITH MANUFACTURER'S INSTRUCTIONS AND RECOMMENDATIONS.
B. PLACE NEW AND RELOCATED UNITS IN FINAL LOCATION AFTER FINISHES HAVE BEEN COMPLETED IN EACH AREA. VERIFY
THAT CLEARANCES ARE ADEQUATE FOR PROPER OPERATION OF EQUIPMENT.
C. REFER TO DIVISION 16 FOR ELECTRICAL REQUIREMENTS.
3.02 ADJUSTMENT AND CLEANING
A. TEST EACH ITEM OF PANTRY EQUIPMENT TO VERIFY PROPER OPERATION. MAKE NECESSARY ADJUSTMENTS.
B. VERIFY THAT REQUIRED ACCESSORY ITEMS HAVE BEEN FURNISHED AND PROPERLY INSTALLED.
C. LEAVE UNITS IN CLEAN CONDITION, READY FOR OPERATION.
END OF SECTION 11450
P�
C
Z
O
Z
U
O0Q
C
N y
O
to
J J
=
J j
Cu
Q
,
V V
3:
�4
LLJ
U
Z 04
W
11 M
O coo
��o<
cr_ OR
Cr) " M
Z mLoO
U>oroL.L�
L1J
� -xo
� i ~ (=:>
U) U) Z �o W
w
Z � R�: TW
Q
O Q p rn W
Z
m
ULij J W°O�
�
WC7 � W
�
>
J
OLCI I
M J
� LLI W
W .4 U H
OD
j
P�
0IIIM
N
0
U
�
�4
LLJ
U�
<
W
M
N
��o<
Z
of
L1J
}
0
w
I-
Q
Z
�
J
>
J
QUImI
j
N
U
M2
LJ..
z
qt
T_
Q
U
I
project no.
210780.03
drawn check by
MC BP
FULL SCALE (24X36):
1/8" = V-0"
HALF-SIZE (12X18):
1/16"= V-0"
(unless otherwise noted)
sheet
AS -4
ARCHITECTURAL
SPECIFICATIONS
0
N
w
N
I
A
FULL SCALE (24X36):
1/8" = V-0"
HALF-SIZE (12X18):
1/16"= V-0"
(unless otherwise noted)
sheet
AS -4
ARCHITECTURAL
SPECIFICATIONS