A-2.1
CONSTRUCTION PLAN
1/4" = 1'0"
GENERAL NOTES
1. G.C. TO PATCH & REPAIR TO NEW CONDITION ANY DEMISING WALL,
CORRIDOR, OR OTHER PROPERTY THAT IS DAMAGED DURING
DEMOLITION OR CONSTRUCTION. G.C. TO MATCH ALL STANDARD
FINISHES.
2. (NOT USED)
3. ALL DIMENSIONS SHOWN ARE FROM FINISH FACE TO FACE PARTITION
OR DAY LIGHT OF FRAME. WHEN LAYING OUT PARTITIONS ALL ROUGH
OPENINGS AND FINISHED WALL CASE DIMENSIONS SHALL BE
COORDINATED/CONFIRMED WITH MILLWORK.
4. ANY PARTITIONS NOT TAGGED SHALL BE CONSTRUCTED AS NOTED
FOR GENERAL PARTITION TYPE C.
5. DIMENSIONS INDICATED THUS:
�T-0"
HOLD 1
MUST BE EXPLICITLY HELD - NO EXCEPTIONS
6. ALL FRAMING LUMBER, PLYWOOD AND CONCEALED WOOD SHALL BE
FIRE RETARDANT TREATED (F.R.T.) - NO WOOD IN CEILING PLENUM OF
ABOVE SPRINKLER COVERAGE.
7. PROVIDE METAL OR F.R.T. WOOD BLOCKING FOR ALL SIGNS AND ANY
OTHER WALL -MOUNTED EQUIPMENT. COORDINATE ALL BLOCKING
REQUIREMENTS NECESSARY FOR MILLWORK WITH MILLWORK
SUPPLIER.
8. G.C. SHALL LEAVE NO GAPS AND FILL SOLID TO PIPING AND
DUCTWORK TO MAINTAIN THE STRUCTURAL INTEGRITY OF DEMISING
WALLS AND MAINTAIN FIRE SEPARATION AS REQUIRED.
9. CONVENIENCE OUTLETS MOUNTED AS REQUIRED BY APPLICABLE
REGULATORY REQUIREMENTS U.O.N. CONVENIENCE OUTLETS TO
MATCH ADJACENT WALL COLOR AS REQUIRED. OUTLETS TO BE
LOCATED SO AS TO BE AS INCONSPICUOUS AS POSSIBLE.
10. G.C. SHALL BE RESPONSIBLE FOR COORDINATING WITH OWNER ON
ALL WORK TO BE PERFORMED BY THE OWNER. ANY POTENTIAL
CONFLICTS OR DELAYS CAUSED BY THE OWNER'S SUBCONTRACTORS
MUST BE DOCUMENTED IN WRITING TO THE OWNER BEFORE THE DELAY
IS ACTUALLY INCURRED FOR IT TO BE CONSIDERED OTHERWISE THE
G.C. WILL BE RESPONSIBLE FOR MEETING THE SCHEDULE AS OUTLINED
IN THE CONTRACT
11. G.C. SHALL SUPPLY ALL MATERIALS, LABOR & COORDINATION
REQUIRED FOR THE INSTALLATION OF ALL OWNER -SUPPLIED ITEMS AS
DESCRIBED IN THE DOCUMENTS, U.O.N.
12. G.C. IS RESPONSIBLE FOR ALL FLOOR AND WALL PENETRATIONS
FOR MECHANICAL, ELECTRICAL OR PLUMBING WORK. ALL SUCH
OPENINGS SHALL BE FRAMED AND REINFORCED. NO PENETRATIONS
SHALL BE CUT THROUGH DEMISING WALLS, FLOORING, OR MALL
STRUCTURE WITHOUT PRIOR AUTHORIZATION BY THE OWNER AND
MALL MANAGEMENT.
13. ALL EXISTING FIREPROOFING TO BE MAINTAINED. DAMAGE OR
REMOVAL OF FIREPROOFING MUST BE REPAIRED OR REPLACED AT NO
COST TO THE OWNER.
14. G.C. SHALL BE RESPONSIBLE TO MAINTAIN THE STRUCTURAL,
ARCHITECTURAL AND FIRE -RATED INTEGRITY OF DEMISING WALLS,
FLOOR SLAB, BEAMS, COLUMNS AND ROOF STRUCTURE.
15. PROVIDE FIRE EXTINGUISHER WITH RECESSED CABINET (FEC)
WITHIN 75 FEET TRAVEL DISTANCE OF ALL POINTS IN THE OCCUPANCY.
INSTALLED LOCATIONS TO BE APPROVED BY ARCHITECT.
16. G.C. SHALL PATCH AND REPAIR EXISTING SURFACES AS NECESSARY
BEFORE APPLYING NEW FINISHES. ALL SOFT, POROUS, FLAKING OR
OTHERWISE DEFECTIVE FINISHES WILL BE REMOVED BEFORE
APPLICATION OF NEW MATERIALS. OPENINGS, VOIDS OR UNFINISHED
SURFACES CREATED BY REMOVAL OR MODIFICATION OF EXISTING
WORK SHALL BE FILLED OR PATCHED AND FINISHED AS NECESSARY TO
MATCH CONTINUOUS SURFACES. FLOOR SURFACES AT ENTRY SHALL
BE LEVELED TO ASSURE SMOOTH SURFACE FINISH FLOOR
INSTILLATION.
M KEY NOTES
LINE OF FASCIA OR COVE ABOVE, SEE RCP.
ELECTRICAL PANEL BOARD. G.C. TO PROVIDE BLOCKING AS REQUIRED.
EDWALL MOUNTED FIRE EXTINGUISHER.
a❑ RECESSED KEYPAD/SWITCH BOX. THE MASTER LIGHTING CONTROL
SWITCH, AND ALARM KEYPAD ARE SURFACED MOUNTED INSIDE
CUSTOM BOX.
Q5 DASHED LINE INDICATES BUILT-IN MILLWORK, REFER TO ELEVATIONS
AND FIXTURE PACKAGE FOR MORE INFORMATION.
❑6 SEE A-4.2 FOR BACK OF HOUSE AREA.
0 NEW STORE FRONT CONSTRUCTION; REFER TO A-5.1 SERIES
a❑ ALL EXPOSED WALL PARTITIONS TO BE LEVEL 5 FINISH EXCEPT FOR
BACK OF HOUSE AREA.
❑s FURR OUT AROUND EXISTING STRUCTURAL COLUMNS
10 REFER TO A-6.1 FOR PARTITION TYPES AND DETAILS
11 EXIT PATH STRIPING TO BE FOUND A SHEET A-2.2
12 24" X 24" ACCESS PANEL ABOVE. GLENDON COMPANY GFRG
FIBERGLASS ACCESS PANEL
13 PROVIDE AND INSTALL ROCKETFISH LOW PROFILE TILTING WALL MOUNT
FOR WEB ACCESS PANEL. REFER TO MEP. MODEL: RF-TVMLPT01,
COLOR: BLACK. ELECTRICAL CONTRACTOR TO POSITION DATA
RECEPTACLE CLOSE TO CENTER OF MOUNT IN ORDER MINIMIZE
VISIBILITY OF RECEPTACLE AND WIRING. GC TO COORDINATE
BLOCKING LOCATIONS WITH APPROVED SHOP DRAWINGS
14 PROVIDE CONTINUOUS BLOCKING AT ALL FITTING ROOM WALLS
D7
01' 3' 5' N
LEGEND
EXISTING WALL TO REMAIN
NEW CONSTRUCTION
NOTE TAG, REFER
TO KEYED NOTES
�— PARTITION TYPE SYMBOL & LETTER
REFER TO SHEET A-6.1 FOR PARTITION TYPES AND DETAILS
10o DOOR NUMBER. REFER SHEET A-7.1.
CASS�4
No 1
(� STAT OF
pNA P
project no.
210780.03
drawn check by
MC BP
E
Z
O
Z
U
O 0
c
N y
O
U
J J
=
J J
cc
a
U
O
W
g
d
Z C14
M
a�
W 00
C)
0 CV m
Z C7 Lo OU
O m
V �
Cn Cn Z o- W
Z M ?: qc:r W
O Q O rn m
Qoz
J
Lu
LCV W
0
Q
m 0
W
J
W � (5
`7J
U
project no.
210780.03
drawn check by
MC BP
®
ch
W
0
U
O
W
g
It
cy
a�
W
C)
z
�W>o
�-
Qoz
Q
J
U
J
—�
`7J
U
CO
W
�-+
M
a
U
project no.
210780.03
drawn check by
MC BP
FULL SCALE (24X36):
1/8"= 1'-0"
HALF-SIZE (12X18):
1/16"= 1'-0"
(unless otherwise noted)
sheet
Am2ml
CONSTRUCTION
PLAN
0
a�
N
rn
A
FULL SCALE (24X36):
1/8"= 1'-0"
HALF-SIZE (12X18):
1/16"= 1'-0"
(unless otherwise noted)
sheet
Am2ml
CONSTRUCTION
PLAN