HomeMy WebLinkAbout29STEEL DECK WALL - THREAD ROD.
TOP BEAM C -CLAMP GTH AS REQUIRED
IF STEEL BAR JOIST PIPE SLOPE (TYPICAL)
CLEVIS HANGER FOR PIPE
PRO VIDE COPPER 0 VER FOUR INCHES
OR NDN -METALLIC SAFETY MIXING VA VE APPROVED UNDER
COA TING WHERE PROVIDE GALVANIZED STEEL ASSE 1016 OR 1017 MAX. WATER TEMP. OF 3/4" HOT WATER TO FIXTURES
ADJUSTABLE BAND HANGERS CONTACT SADDLE FOR ALL INSULATED PIPE 110 'F (105 DEG. F)
HANGER FOR PIPING BARE COPPER PIPE INSULA TION THLARGER THAN 3/4 . VER/FY
314" TP_ � FOUR INCHES OR LESS Q SIZING HANGERS.KNESS WHEN 3/4" HOT WA TE _. � /
3 4" COLDVA CUUM
A TER SUPPLY
I ELECTRIC WA TER HEA TER EI
I I 1 3/4 "CW
I I
TEMPERA7URE & PRESSURE I
RELIEF VAL VE � I
EXPANSION TANK.
NOTE: TEMPERA TURE & PRESSURE o CHECK VALVE
WH -1 PROVIDE UPPER ATTACHMENT AS REQUIRED FOR CASES NOT SHOWN HERE. DO NOT INSTALL HANGER INSIDE REL/EF DRAIN DISCHARGE TO
INSULATION OR OTHERWISE PENETRATE VAPOR BARRIER. DO NOT HANG ONE PIPE FROM ANOTHER EXCEPT IN FLOOR DRAIN I
CHASES. TRAPEZE HANGERS MAY BE USED FOR MULTIPLE PARALLEL PIPES. HANGER SPACING FOR PIPE SIZE: UNION(TYPICAL)
COPPER: 4"=12' 3"=11' 2-1/2"=10' 2"=9' 1-1/2"=8' 1-1/4"=7' 1"=6' 3/4"=6' 1/2"=5'. CAST IRON: 10' G GAUGE 4 H
.� � GALVANIZED SAFETY PAN � STEEL TONIC STRAPS SHALL BE 2" WIDE
1/2» AND ONE NEAR ALL JOINTS. STEEL: 4"=14' 3 =12 2-1/2"=11' 2"=10' 1-1/2"=g' 1"=7' 3/411=691/2 =5.
LOCATE HANGERS AS CLOSE AS POSSIBLE TO TURNS AND TEES OF PIPE. PROVIDE SUPPLEMENTARY STEEL OVER PLATFORM CEILING GRAIN VALVE 22 GAUGE SHEET METAL, FASTEN TO WALL
STRUTS BETWEEN JOISTS IF REQUIRED.LOCATE HANGERS TO TAKE LOAD OFF OF EQUIPMENT CONNECTIONS. EACH
(2) #8 SELF TAPPING SCREWS CH END. PROVIDE BLOCKING IN WALL. 1
ANCHOR WATER PIPE AGAINST SWAYING DUE TO CHANGES IN WATER VELOCITY. PROVIDE SEISMIC BRACING EA
/3 DISTANCE ON HEATER
IF/AS REQUIRED BY LOCAL AUTHORITIES. CHAINS OR PERFORATED STRAP IRON OR STEEL IS NOT
ACCEPTABLE. REFER TO CODES FOR FURTHER INFORMATION.
1 "DRAIN -TAIL PIECE OF LAV OR
ACCEPTABLE RECEPTOR
1/2"
1/2» we -1
FD -1 \
LAV -1 3 PIPE INSULATION/HANGER DETAIL 6 WATER HEATER DETAIL
OF -1 P-1.2 NOT TO SCALE P-1.2 NOT TO SCALE
MEMBRANE CLAMP FLOOR SLAB ON GRADE
-
1 WATER RISER DIAGRAM SAME SIZE AS SEWER UP
AS REQUIRED FOR TO 4" MAXIMUM
DEPTH OF SEWER SHUT-OFF VALVE
LONG SWEEP ELBOW AT
P-1.2 NOT TO SCALE HUB AND SPIGOT PVC
END OR TURN OF RUN WALL ACCESS PANEL
PIPE BELOW FLOOR
COMBINATION WYE AND CW PIPING
SANITARY OR STORM EIGHTH BEND IN RUN.
SEWER LINE ENTER TOP OF PIPE
TRAP PRIMER
< AIR GAP FITTING GRATE
FINISHED FLOOR
NOTES. FLOOR DRAIN
4" VTR 1. LOCA TE A T BUILDING EXIT, A T ENDS OF RUNS, A T TURNS OF PIPE
GREA TER THAN 45 DEGREES, A T 50' INTERVALS ON STRAIGHT
RUNS, AND WHERE SHOWN ON PLANS. PROVIDE BACKFILL PER
ARCHITECTURAL SPECIFICATIONS. LOCATE CLEANOUTS WHERE THERE
IS 18" CLEAR AROUND. CONSULT LOCAL CODES FOR OTHER FCO CAULK OUTLET
3„ REQUIREMENTS.
2. PRO WDE ROUND SECURED NICKEL BRONZE ADJUSTABLE TOP WITH
3„ "CO" CAST IN COVER. PROVIDE CLEANOUT TOP WITH VARIATIONS
SUITABLE FOR FLOOR COVERING (CARPET MARKER, RECESSED
FOR TILE, SCORIA TED FOR UNFINISHED FLOORS). PROVIDE 1/2" PIPING TO TRAP
BRONZE PLUG IN PVC BODY. TYP. OF 2
\ 2 " DEEP SEAL "P" TRAP
I I
I 7
2" 4 FLOOR CLEANOUT DETAIL 7 TRAP PRIMER DETAIL
3"2 •,
r I P-1.2 NOT TO SCALE P-1.2 NOT TO SCALE
WCO-1
I
WC -1V- TERMINATE SLEEVE FLUSH WITH
3 'I FINISHED WALL SURFACES
2
SEAL OR CAULK SLEEVES STANDARD WEIGHT STEEL PIPE
�
THRU FIRE WALLS IN SMOKE SLEEVE OF SIZE TO PASS PIPE
B 0 L__:E;
TIGHT MANNER AND TO MEET AND INSULATION. PLUS GAP AS
co
FD -1 3"
4 FIRE RATING OF WALL (REFER REQUIRED BY LOCAL CODES.
P L
TO ASTM E-814) (25 GA. SPLIT WALL SLEEVE
O
ALSO ACCEPTABLE)
SYMBOL
4"
SYMBOL
PROVIDE FOR ALL MASONRY WALLS
SYMBOL
PIPE AND INSULA710N TO BE AND FIRE RA TED WALLS
,.
CENTERED IN SLEEVE -DO NOT
0(00.0000
SUPPORT PIPE FROM SLEEVE FINISHED ESCUTCHEON PLATE FLUSH
AGAINIST WALL AND OF SIZE TO
WATER CLOSET (TANK TYPE)
COUPLE TEL Y COVER OPENING
SANITARY DRAIN BELOWGROUND
FINISHED WALL SURFACE
GLOBE VALVE
CONCEALED PIPING PIPING EXPOSED TO VIEW
�O WC
2 SANITARY/VENT RISER DIAGRAM 5 PIPE SLEEVE AT INTERIOR WALLS
P-1.2 NOT TO SCALE P-1.2 NOT TO SCALE
W.
w
�
S YM
B 0 L__:E;
Z
co
W
P L
U M B I N G
O
�z �-
SYMBOL
DESCRIPTION
SYMBOL
DESCRIPTION
SYMBOL
DESCRIPTION
,.
SANITARY DRAIN ABOVEGROUND
0(00.0000
GAS COCK
noWC
WATER CLOSET (TANK TYPE)
-=--ter
SANITARY DRAIN BELOWGROUND
-—
GLOBE VALVE
W CC!
�O WC
WATER CLOSET (FLUSH VALVE)
VENT LINE CHECK VALVE
\�
s—
STORM DRAIN ABOVEGROUND
--A&—
PRESSURE RELIEF VALVE
rj UR
t'
URINAL
�S=
STORM DRAIN BELOWGROUND
Cn C13Z W
STOP AND WASTE VALVE
z m w
OQOa'm
LAV
LAVATORY
-- COLD WATER (CW) STOP AND WASTE VALVE (IN RISE)
----
HOT WATER (HW)
----07*—
MIXING VALVE
®
KS
KITCHEN SINK
----
G
HOT WATER CIRCULATING (HWC)
GAS LINE
PRESSURE REGULATING VALVE (PRV)
® SS
SERVICE SINK
q4
UNION
I+\ HB
HOSE BIBB
DF
DRINKING FOUNTAIN
—
STRAINER
I--IWH
WALL HYDRANT
EVC
ELECTRIC WATER COOLER
BALANCING COCK if FH FIRE HYDRANT
-ESO—
RUNNING TRAP
O MH
MANHOLE
>--
COLUMN NUMBER
c --O
CLEAN OUT
+m
VALVE IN RISE
0—
PLUMBING RISER NUMBER
---G—C13 0 GRADE CLEAN OUT ®D-1 DRAIN AND MARK
N.I.T.C.
NOT IN THIS CONTRACT
ORD
ROOF DRAIN
VTR
VENT THROUGH ROOF
ODS
DOWN SPOUT
——
VACUUM BREAKER
V.C.P.
VITRIFIED CLAY PIPE
— �—
BALL VALVE
C.I.
CAST IRON
I.E.
INVERT ELEVATION
W.
w
�
Lu
z
c
o
Z
co
W
XW
��_tQi
N U)
O
�z �-
Z a � 00 ,1
Lu J
a N
C14Go
a.a YqqcC11
z z
a�CC ,
O O
,.
/////lI11101111i`t`0
0(00.0000
W.
w
�
Lu
z
c
o
Z
co
W
XW
��_tQi
N U)
O
�z �-
Z a � 00 ,1
Lu J
a N
C14Go
a.a YqqcC11
z z
a�CC ,
O O
-
O U
0(00.0000
project no.
xxxxxx.00
drawn check by
HDU BB
E
ZU
Z
O
c
N U)
O
_J
J
J J
Cu
a 4
-
V
M
t-4
U
U
Z
M
W CC!
0 N
Z c M ,i 0
O co
ULu co
jr—LL.
>_
Cn C13Z W
z m w
OQOa'm
Z
N
Lu .J 0 N_ W
W 0 In
mtiww
�--
project no.
xxxxxx.00
drawn check by
HDU BB
®
W
M
t-4
U
o
U�ItOCWMZ
F-
Q
L1J
>_
Z
N
},Ji
�UmW
V
S
M
Q
U
project no.
xxxxxx.00
drawn check by
HDU BB
FULL SCALE (24X36):
1/8" = V-0"
HALF-SIZE (12X18):
1/16"= 1'-0"
(unless otherwise noted)
sheet
Pml 02
PLUMBING
RISERS AND DETAILS
N
S
FULL SCALE (24X36):
1/8" = V-0"
HALF-SIZE (12X18):
1/16"= 1'-0"
(unless otherwise noted)
sheet
Pml 02
PLUMBING
RISERS AND DETAILS