Loading...
HomeMy WebLinkAbout6DOORS & MANEUVERING CLEARANCES WATER CLOSETS & TOILET STALLS SPACE ALLOWANCES & REACH RANGES 4.13 DOORS. 11-4.16 WATER CLOSETS. 4.13.1 General. Doors required to be accessible by 4.1 shall 11-4.16.1 General. Accessible water closets shall comply with Toilet Stall New ConstructionLicomply with the requirements of 4.13. 11-4.16.2 Clear Floor Space. Clear floor s 3 3 3 3 10 max 30 4.13.2 Revolving Doors and Turnstiles. Revolving doors pace for water � m m � 30 24 or Turnstiles shall not be the only means of passage at an closets not in stalls shall comply with Fig. 28. Clear floor o o 60 min o 0 accessible entrance or along an accessible route. An min space may be arranged to allow either a left-handed or right- E E E accessible gate or door shall be provided adjacent to the 1220 handed approach. 3 18 ; f— turnstile or revolving door and shall be so designed as to ' I y facilitate the same use pattern. 11-4.16.3 Height. The height of water closets shall be 17" to ay. 4.13.3 Gates. Gates, including ticket gates, shall meet all 19" (430 mm to 485 mm), measured to the top of the toilet seat 19"x17 / applicable specifications of 4.13. ,\ — (see Fig. 29(b)). Seats shall not be sprung to return to a lifted I I N position. LO LO „o 8 � v w J 4.13.4 Double -lea Doorways. doorways have two _ I I independently operated door leaves, then at least one leaf 11-4.16.4 Grab Bars. Grab bars for water closets not located shall meet the specifications in 4.13.5 and 4.13.6. That leaf E shall be an active leaf. in stalls shall comply with 11-4.26 and Fig. 29. The grab bar I ' behind the water closet shall be 36" (915mm) minimum. �° a 4.13.5 Clear Width. Doorways shall have a minimum clear opening of 32"(815mm) with the door open 90°, measured 11-4.16.5 Flush Controls. Flush controls shall be hand between the face of the door and the opposite stop Fi shall comply with 11-4.27.4. Controls 10 max 30 PP Psee 9• operated or automatic and � 24(a),(b),(c) and (d)). Openings more than 24"(610mm) in afi min a) for flush valves shall be mounted on the wide side of toilet 255 ( (c) (b) depth shall comply with 4.2.1 and 4.3.3 (see Fig. 24(e)). 1220 areas no more than 44" 1120mm above the floor. ( ) Clear Floor Space Parallel Approach Maximum Side Reach Over Obstruction High and Low Side Reach Limits EXCEPTION: Doors not requiring full user passage, such as shallow closets, may have the clear opening reduced to 20" r'_111-4.16.6 Dispensers. Toilet paper dispensers shall be (510mm) minimum. f _ installed within reach, as shown in Fig. 29(b). Dispensers that 42 min 12 max Fig. 6 4.13.6 Maneuvering Clearances at Doors. Minimum 1 __ control delivery, or that do not permit continuous paper flow, maneuvering clearances at doors that are not automatic or j shall not be used. power -assisted shall be shown in Fig. 25. The floor or ground L — — — _ — — area within the required clearances shall be level and Gear. 11-4.17 TOILET STALLS. I JE co EXCEPTION. Entry doors to acute care hospital bedrooms for in -patients shall be exempted from the requirement for space 11-4.17.1 Location. Accessible toilet stalls shall be on an I 12 max Aid at the latch side of the door (see dimension "x" in Fig. 25) if the accessible route and shall meet the requirements of 11-4.17.I Q Side Reach door is at least 44" 1120mm 54 min wide. Fig.26 11-4.17.2 Water Closets. Water closets in accessible stalls =_ 4.13.7 Two Doors in Series. The minimum space between Two Hinged Doors in Series 42 minshall comply with 11-4.16. E two hinged or pivoted doors in series shall be 48"(1220mm) .wall mounted w.c. E 42 min latch 66 min w plus the width of any door swinging into the space. Doors in approach only. M series shall swing either in the same direction or away from the 11-4.17.3 Size and Arrangement. The size and arrangement otnerapproaches g 48 min 69 min w.ltr, mounted w.c. space between the doors (see Fig. 26). of the standard toilet stall shall comply with Fig. 30(a), 4.13.8* Thresholds at Doorways. Thresholds at Standard Stall. Standard toilet stalls with a minimum depth of doorways shall not exceed 3/4"(19mm) in height for exterior x 56" (1420mm)(see Fig. 30(a)) shall have wall -mounted water sliding doors or 1/2"(13mm) for other types of doors. Raised -tel closets. If the depth of a standard toilet stall is increased at thresholds and floor level changes at accessible doorwaysI I I- T- — — -j least 3" (75mm), then a floor -mounted water closet may be E -2 shall be beveled with a slope no greater than 1:2 (see 4.5.2). used. Arrangements shown for standard toilet stalls may be "' v 4.13.9* Door Hardware. Handles, pulls, latches, locks and co E I I E � I I I reversed to allow either a left or right-hand approach. other operating devices on accessible doors shall have a tO I \ I 18 min. 24 preferred v I I I Additional stalls shall be provided in conformance with 11-4.22.4. 12 max shape that is easy to grasp with one hand and does not I 455 I I I EXCEPTION: In instances of alteration work where provision 54 min 3s min a6 min 3s min I, U require tight grasping, tight pinching, or twisting of the wrist to operate. Lever -operated mechanisms, and U-shaped handles i n of a standard stall (Fig. 30(a)) is technically infeasible or a2 min az min are acceptable designs. When sliding doors are fully opened, t II where plumbing code requirements prevent combining existingNOTE: x = 12 in (305 mm) if door has both a (b) NOTE: Dimensions Shown apply When x less than 48 in (1220 mm). operating hardware shall be exposed and usable from both closer and lata,. \ stalls to provide space, either alternate stall (fig. 30(b)) may Alternate Stalls (a) (b) sides. Hardware required for accessible door passage shall (a) _I1 be provided in lieu of the standard stall. Turns around an Obstruction be mounted no higher than 48"(1220mm) above finished floor. Front Approaches - Swinging Doors 90°Turn EXCEPTION: New Construction N 4.13.10* Door Closers. If a door has a closer, then the (1) The standard accessible restroom stall shall contain o sweep period of the closer shall be adjusted so that from an 54 min an accessible lavatory within it, the size of such X open position of 70°, the door will take at least 3 seconds to — — — "-'" — "- — — i 1370 lavatoryto be not less than 19 inches wide b 17 E 2 y 36 min 4 max 32 min � move to a point 3"(75mm) from the latch, measured to the r1\ I _ _ inches deep, nominal size, and wall mounted. The—�altemate L J door location leading edge of the door. I � — 1 lavatory shall be mounted so as not to overlap the clear } _ U, I ( floor space areas required by Section 11-4.17 (See I x 4.13.11 Door Opening Force. The maximum force for \ x I } E Figure 30(a) and (e)) and to comply with Section E pushing or pulling open a door shall be as follows: �� < I ( 111-4.19 of the code. Such lavatories shall be counted I E (1) Fire doors shall have the minimum opening force i as part of the required fixture count for the building. clear ° W allowable by the appropriate administrative authority. floor ,i (2) The accessible water closet shall be located in the spate I (c) Fig. 7 (d) (2) Other doors: NOTE: x = 36 in (915 mm) minimum if y = 60 in NOTE: y=48 in (1220 mm) minimum 1f door has x Changes in Level changes in level (a) exterior hinged doors: (Reserved). (1525 mm): x = 42 in (1063 mm) minimum iF y = born a latch and closer. I I comer, diagonal to the door. nj 4 12 max E Accessible Route (b) interior hinged doors: 51bf(22.2N). (b> . `O 54 in (1370 mm) ` ll 56 in w/ wall mounted w.cI 52 min (c) sliding or folding doors: 5 Ibf(22.2N). Hinge Side Approaches - Swinging Doors 11-4.17.4 Toe Clearances. In standard stalls, the front partition 59 min w/ fir. mounted w.c. TYPICAL MOUNTING HEIGHTS These forces do not apply to the force required to retract latch and at least one side partition shall provide a toe clearance of 56 min w/ wall mounted w.c. bolts or disengage other devices that may hold the door in a at least 9" (230mm) above the floor. If the depth of the stall is a2 min latch 59 min w/ fir. mounted w.c. y x 24 min 24 min x approach only. closed position. "�`�j`-610 610 greater than 60" (1525mm), then the toe clearance is not required. other approaches 48 min 4.13.12* Automatic Doors and Power -Assisted Doors. If (a) v — — �Standard stall an automatic door is used, then it shall comply with o I I I I 11-4.14.5 Door. Toilet stall doors, including door hardware, E N ANSI/BHMA A156.10-1985. Slowly opening, low -powered, } ", \ a } shall comply with 11-4.13. If toilet stall approach is from the latch automatic doors shall comply with ANSI A 156.19-1984. Such I , I I I side of the stall door, clearance between the door side of the doors shall not open to back check faster than 3 seconds and ) stall and any obstruction may be reduced to a minimum of 42" shall require no more than 15 Ibf(66.6N) to stop door I movement. If a power -assisted door is used, its door -opening l (1065mm) (see Fig. 30). Doors shall not swing into the clear floor force shall comply with 4.13.11 and its closing shall conform to NOTE: y = 54 in (1370 mm) minimum 'rf door has NOTE: y = 481n (1220 mm) minimum if door has space of any fixture. requirements in ANSI A 156.19-1984. clO5er. closer•\ I 6" (c) 11-4.17.6 Grab Bars. Grab bars complying with the length and Latch Side Approaches - Swinging Doors alternate THERMOSTAT 4.14 ENTRANCES. positioning shown in Fig, 30(a),(b),(c) and (d) shall be 36 min 12 max 401421 mm 4.14.1 Minimum Number. Entrances required to be 54 min provided. Grab bars may be mounted with any desired 915 305 1015110451 accessible by 4.1 shall be part of an accessible route 1370 method as long as they have a gripping surface at the 36 max complying with 4.3. Such entrances shall be connected by an _ _ WALL TELEPHONE accessible route to public transportation stops, to accessible — — locations shown and do not obstruct the required Gear floor o 915 -o SWITCHES/DIMMER I I F — area. Grab bars shall comply with 11-4.26. cr parking and passenger loading zones, and to public streets or o I I ,c 4 q sidewalks if available (see 4.3.2(1)). They shall also be N I �. I E o 10��� �, OUTLETS connected by an accessible route to all accessible spaces orv I I I I "' M CD G v E co N cn elements within the building or facility. I Fig. 28 \ co T c� r Clear Floor Space at Water Closets (d) (e) 36 min (c) (d) Front Approach - Sliding Doors Side Side Approach - Sliding Doors 18 36 min Rear Wall of Standard Stall Side Walls and Folding Doors and Folding Doors 18 min. 18 1a min TYP. LOCATION FOR LIGHT SWITCHES, TYP. LOCATION FOR LIGHT SWITCHES, x 24 min PHONE OUTLETS AT WALL OR COLUMN sto lay. 32 min NOTE: All doors in alcoves I— — — — - lay. I 32 MIN shall comply with the clearances 815 815 for front approaches p[ (/(_ Co I C I I floorfloorI ' clear space space I 1 4 4 J (a) (b) 48 min 48 min Details Hinged Door (f) Latch Side Approach - Sliding Doors and Folding Doors FIXED SHELF, PAINTED 42 min 18 GARMENT WOOD, TYP. 32 min HOOK 815 32 min Fig. 25 CHROME ROD & 815 Maneuvering Clearances at Doors (Continued) c3 -r ESCUTHEON PLATE (c) I Sliding Door 1 r WCLOSET OPENINGS SEE dear s^ DOOR SCHED. FOR DOOR ]-E o�� o AND FRAME TYPE 32 minm L---- n 815 4 DIVIDER, (d)(e) so min t c� PAINTED WOOD Folding Door Maximum Doorway Depth Fig. 24 Clear Doorway Width and Depth TYP. LOCATION FOR WALL HUNG TYP. LOCATION FOR DOOR PULLS Fig. 29 g TELEPHONE Grab bars at Water Closets THE DETAILS WITHIN THIS SHEET ARE FOR REFERENCE ONLY F 36 min (a) Baric Wall 54 min 12 max 42 mint toilet paper Lt4� GRAPHIC LEGEND Z O Z U O �� NEW GWB PARTITION�—O DETAIL REFERENCE PARTITION TYPES o' -0o^ CRITICAL DIMENSION O J J _ J J TO BE V.I.F. r TO REMAIN w1 WINDOW TAG o ELEVATION REF Q REVISION NUMBER (b) Side wall _ _ _ 1 TO BE REMOVED G.C. DOOR NUMBER ® G.C. MILLWORK M Qf OR W W C) 0 NEW DOOR NEW FIRERATED PART �� GRAIN DIRECTION LU 00 SECTION REF >_0 \p CASS�O J.' G T ERGO No 10900 53 ; STATE OF //y P V project no. 210780.03 drawn check by MC BP Z O Z U O c N H O J J _ J J to Q U U o 3 z C14 M Qf OR W W C) 0 Z O cMinO co CL: LU 00 W >_0 U) w v QOZ O Q OZ rn m _ 1 Cq >_J W c_V W J m O U'3 LJJ J w�(9�� CO W project no. 210780.03 drawn check by MC BP ® M W 0 U o U� 0 Q M m W W C) Z W >_0 �- QOZ >_J J QU CO W N U M T_ Q U project no. 210780.03 drawn check by MC BP FULL SCALE (24X36): 1/8" = 1'-0" HALF-SIZE (12X18): 1/16" = 1'-0" (unless otherwise noted) sheet A=056 ADDITIONAL NOTES & ACCESSIBILITY INFORMATION 0 m N A FULL SCALE (24X36): 1/8" = 1'-0" HALF-SIZE (12X18): 1/16" = 1'-0" (unless otherwise noted) sheet A=056 ADDITIONAL NOTES & ACCESSIBILITY INFORMATION