Loading...
HomeMy WebLinkAbout8SECTION 06100 - ROUGH CARPENTRY PART 1 - GENERAL 1.01 SUMMARY OF WORK A. THE WORK OF THIS SECTION INCLUDES, BUT IS NOT NECESSARILY LIMITED TO, THE FOLLOWING: WOOD NAILERS AND BLOCKING B. RELATED WORK SPECIFIED ELSEWHERE ARCHITECTURAL WOODWORK - SEE SECTION 06400. 1.02 REQUIREMENTS OF REGULATORY AGENCIES FIRE -RETARDANT TREAT ALL WOOD AND PLYWOOD PROVIDED IN THE WORK OF THIS SECTION. 1.03 SUBMITTALS CERTIFICATION OF FIRE RETARDANT TREATMENT: SUBMIT CERTIFICATION STATING NAME OF FIRE RETARDANT MATERIALS USED, COMPLIANCE WITH LOCAL BUILDING CODE REQUIREMENTS AND COMPLIANCE WITH AWPA SPECIFICATIONS C1 AND C20 FOR LUMBER AND C27 FOR PLYWOOD. 1.04 DELIVERY, STORAGE AND HANDLING KEEP ROUGH CARPENTRY WORK DRY DURING DELIVERY, STORAGE AND INSTALLATION AND UNTIL FINISH IS APPLIED AND BUILDING IS ENCLOSED. PROVIDE FOR AIR CIRCULATION IN STACKS OF LUMBER AND PLYWOOD. PART2-PRODUCTS 2.01 MATERIALS A. GENERAL 1. LUMBER GRADING: COMPLY WITH "SIMPLIFIED PRACTICE RECOMMENDATIONS PS -20, AMERICAN SOFTWOOD LUMBER STANDARDS" BY THE U.S. DEPARTMENT OF COMMERCE AND WITH THE APPLICABLE LUMBERMEN'S ASSOCIATION RULES UNDER WHICH EACH SPECIES OF LUMBER IS PRODUCED. 2. PLYWOOD GRADING: COMPLY WITH ANSI. 3. GRADE MARKING: FACTORY MARK EACH PIECE OF LUMBER WITH THE OFFICIAL GRADE MARK OF THE APPROPRIATE ASSOCIATION OR AUTHORIZED INSPECTION SERVICE UNDER WHOSE RULES THE LUMBER IS GRADED. 4. SIZES AND PATTERNS: PROVIDE LUMBER WHICH IS DRESSED S4S AND WORKED TO SUCH PATTERNS AS SHOWN OR SPECIFIED. DIMENSIONS ON DRAWINGS DESIGNATE THE NOMINAL UNDRESSED SIZE OF THE ITEM. 5. MOISTURE CONTENT: PROVIDE LUMBER WHICH HAS BEEN SEASONED BY AIR DRYING OR KILN DRYING TO A MOISTURE CONTENT NOT TO EXCEED 19%. B. LUMBER 1. NAILERS AND BLOCKING WITHIN DRYWALL, PLASTER AND VENEER PLASTER PARTITIONS ARE TO BE ONE OF THE FOLLOWING: a. DOUGLAS FIR, NO.2 STRUCTURAL b. SPRUCE, NO.2 STRUCTURAL 2. NAILERS AND BLOCKING, UNLESS OTHERWISE INDICATED ARE TO BE ONE OF THE FOLLOWING: a. DOUGLAS FIR, NO.3 STRUCTURAL b. SPRUCE, NO. 3 STRUCTURAL C. SOUTHERN PINE, NO.3 C. ADHESIVE: TYPES AS RECOMMENDED BY MANUFACTURER FOR USE INDICATED. D. ANCHORS AND FASTENERS 1. BOLTS, NUTS, STUDS: FS FF -B-571 OR FS FF -B575. 2. EXPANSION SHIELDS: FS FF -S-325; GROUP, TYPE, CLASS AND STYLE BEST SUITED FOR THE PURPOSE. 3. LAG SCREWS AND BOLTS: FS FF -8-561; TYPE AND GRADE BEST SUITED FOR THE PURPOSE. 4. NAILS: FS FF -N-105; TYPE AND SIZE BEST SUITED FOR THE PURPOSE. HOT DIPPED GALVANIZED FOR EXTERIOR. 5. TOGGLE BOLTS: FS FF -B588; TYPE AND CLASS BEST SUITED FOR THE PURPOSE. 6. WOOD SCREWS: FS FF -S-111; TYPE AND SIZE BEST SUITED FOR THE PURPOSE. HOT -DIPPED GALVANIZED FOR EXTERIOR. 7. POWER -DRIVEN FASTENERS: MAY BE USED IF PERMITTED BY CODE. 2.02 FIRE RETARDANT TREATED WOOD A. MATERIALS: "NON-COM" (KOPPERS CO., INC.) FOR INTERIOR USE WHERE RELATIVE HUMIDITY IS NORMALLY BELOW 80%; "NCX" (KOPPERS COMPANY, INC.) FOR USE WHERE RELATIVE HUMIDITY IS FREQUENTLY ABOVE 80%. B. TREATMENT: PRESSURE TREAT TO MEET BUILDING CODE REQUIREMENTS AND AWPA SPECIFICATION C1 AND C20 FOR LUMBER AND C27 FOR PLYWOOD AS A MINIMUM. GUARANTEE FIRE RETARDANT MATERIALS NOT TO BLEED THROUGH PAINTED FINISH. C. SIZE WOOD BEFORE TREATMENT SO THAT MINIMUM CUTTING WILL BE REQUIRED AFTER TREATMENT. PART 3 - EXECUTION 3.01 CONDITION OF SURFACE EXAMINE SUBSTRATES, ADJOINING CONSTRUCTION AND CONDITIONS UNDER WHICH THE WORK IS TO BE INSTALLED AND DO NOT PROCEED WITH THE WORK UNTIL UNSATISFACTORY CONDITIONS HAVE BEEN CORRECTED. 3.02 INSTALLATION A. WHENEVER ROUGH CARPENTRY IS FITTED TO OTHER WORK, OBTAIN MEASUREMENTS OF SUCH OTHER WORK. VERIFY DIMENSIONS SHOWN AND THE SHOP DRAWING DETAILS. B. BLOCKING AND NAILERS: PROVIDE BLOCKING AND NAILERS AS SHOWN OR REQUIRED FOR ATTACHMENT OF OTHER WORK. FORM TO SHAPES AS SHOWN AND CUT AS REQUIRED FOR TRUE LINE AND LEVEL OF WORK TO BE ATTACHED. COORDINATE LOCATION WITH OTHER WORK INVOLVED. ATTACH TO SUBSTRATES AS REQUIRED TO SUPPORT APPLIED LOADING. COUNTERSINK BOLTS AND NUTS FLUSH WITH SURFACES, UNLESS OTHERWISE SHOWN. C. REPAIR OF TREATED WOOD SURFACES APPLY HEAVY BRUSH COAT OF SAME FIRE RETARDANT CHEMICALS TO ANY SURFACES WHICH ARE CUT AFTER TREATMENT. D. PRIMING PAINT FIRE RETARDANT TREATED WOOD WITH ONE COAT OF ALKYD TYPE PAINT OR A MOISTURE TRANSMISSION RESISTANT SEALER IMMEDIATELY AFTER INSTALLATION. END OF SECTION 06100 SECTION 06400 - ARCHITECTURAL WOODWORK PART 1 - GENERAL 1.01 SUMMARY OF WORK A. THIS WORK OF THIS SECTION INCLUDES, BUT IS NOT NECESSARILY LIMITED TO, THE FOLLOWING: 1. CASEWORK, WOOD STRIPS, WOOD VENEER, MELAMINE OVERLAY AND PLASTIC LAMINATE CLAD, INCLUDING COUNTERTOPS AND CASEWORK HARDWARE. 2. WOOD DOORS, INCLUDING: a. FLUSH DOORS WITH WOOD VENEER FACES. b. INSTALLATION OF FINISH HARDWARE. 3. FACTORY FINISHING OF ARCHITECTURAL WOODWORK AS INDICATED. B. RELATED WORK SPECIFIED ELSEWHERE 1. GLASS AND GLAZING - SEE SECTION 08800. 2. BLOCKING AND NAILERS - SEE SECTION 06100. 3. HOLLOW METAL DOOR FRAMES - SEE SECTION 08100. 4. MECHANICAL WORK - SEE DIVISION 15. 5. ELECTRICAL WORK - SEE DIVISION 16. 6. FINISH HARDWARE - SEE SECTION 08710. 7. PAINTING - SEE SECTION 09900. 1.02 QUALITY ASSURANCE A. THE WORK OF THIS SECTION SHALL BE PROVIDED BY A FIRM HAVING A MINIMUM OF FIVE (5) YEARS' EXPERIENCE ON PROJECTS OF SIMILAR SIZE AND QUALITY TO THAT SHOWN AND SPECIFIED. B. FIRE -RETARDANT REQUIREMENTS 1. FIRE -RETARDANT TREAT THOSE ITEMS REQUIRED BY APPLICABLE CODES TO BE TREATED AND THOSE ITEMS SHOWN OR SPECIFIED AS "FIRE RETARDANT TREATED WOOD" OR SIMILAR DESIGNATION. 2. MARK EACH UNIT OF FIRE -RETARDANT TREATED WOOD AND PLYWOOD WITH PRODUCER'S LABEL AND A LABEL SHOWING GRADE AND RATING. MARK ON SURFACE WHICH WILL NOT BE EXPOSED AFTER INSTALLATION. 1.03 REFERENCES COMPLY WITH APPLICABLE REQUIREMENTS OF THE MOST CURRENT EDITION OF "ARCHITECTURAL WOODWORK QUALITY STANDARDS", AS PUBLISHED BY THE ARCHITECTURAL WOODWORK INSTITUTE (AWI), EXCEPT AS OTHERWISE MODIFIED BY THE CONTRACT DOCUMENTS OR GOVERNING CODES. 1.04 SUBMITTALS A. PRODUCT DATA: SUBMIT MANUFACTURERS' SPECIFICATIONS AND INSTALLATION INSTRUCTIONS FOR EACH ITEM OF FACTORY -FABRICATED WOODWORK. 1. FIRE -RETARDANT MATERIALS: INCLUDE MANUFACTURER'S INSTRUCTIONS FOR HANDLING, STORING AND INSTALLATION OF FIRE -RETARDANT TREATED MATERIALS. INCLUDE CERTIFICATION THAT FIRE -RETARDANT TREATED MATERIALS COMPLY WITH REQUIREMENTS INDICATED. 2. QUALITY CERTIFICATION: SUBMIT MANUFACTURER'S (FABRICATOR'S) CERTIFICATION, STATING THAT THE FABRICATED WORK COMPLIES WITH QUALITY GRADES AND OTHER REQUIREMENTS INDICATED. B. SHOP DRAWINGS: SUBMIT SHOP DRAWINGS OF ARCHITECTURAL WOODWORK, SHOWING LOCATION OF EACH ITEM, DIMENSIONED PLANS AND ELEVATIONS, LARGE SCALE DETAILS, ATTACHMENT DEVICES AND OTHER COMPONENTS. C. SAMPLES: SUBMIT THE FOLLOWING CONTROL SAMPLES FOR EACH SPECIES AND CUT OR PATTERN OF ARCHITECTURAL WOODWORK: 1. SOLID WOOD WITH FACTORY FINISH: SET OF THREE (3) PIECES, 4" X 3/4" X 18", FOR EACH COLOR AND FINISH: FINISHED ON ONE SIDE AND ONE EDGE. 2. VENEERED PLYWOOD WITH FACTORY FINISH: THREE (3) FINISHED SAMPLES, 12" SQUARE, FOR EACH FINISH, VENEER CUT AND COLOR. 3. CASEWORK HARDWARE: ONE 1 UNIT OF EACH TYPE AND FINISH. 4. PLASTIC LAMINATE AND MELAMINE: 12" SQUARE, EACH TYPE, FINISH AND COLOR. 1.05 DELIVERY, STORAGE AND HANDLING A. PROTECT WOODWORK DURING TRANSIT, DELIVERY, STORAGE AND HANDLING TO PREVENT DAMAGE, SOILING AND DETERIORATION. B. DO NOT DELIVER WOODWORK UNTIL PAINTING, WET WORK, GRINDING AND SIMILAR OPERATIONS WHICH COULD DAMAGE, SOIL OR DETERIORATE WOODWORK HAVE BEEN COMPLETED IN INSTALLATION AREAS. IF DUE TO UNFORESEEN CIRCUMSTANCES, WOODWORK MUST BE STORED IN OTHER THAN INSTALLATION AREAS, STORE ONLY IN AREAS MEETING REQUIREMENTS SPECIFIED FOR INSTALLATION AREAS. 1.06 ENVIRONMENTAL CONDITIONS A. INSTALLER SHALL ADVISE CONTRACTOR OF TEMPERATURE AND HUMIDITY REQUIREMENTS FOR WOODWORK INSTALLATION AREAS. DO NOT INSTALL WOODWORK UNTIL REQUIRED TEMPERATURE AND RELATIVE HUMIDITY HAVE BEEN STABILIZED AND WILL BE MAINTAINED IN INSTALLATION AREAS. B. MAINTAIN TEMPERATURE AND HUMIDITY IN INSTALLATION AREA AS REQUIRED TO MAINTAIN MOISTURE CONTENT OF INSTALLED WOODWORK WITHIN A 1.0 PERCENT TOLERANCE OF OPTIMUM MOISTURE CONTENT FROM DATE OF INSTALLATION THROUGH REMAINDER OF CONSTRUCTION PERIOD. THE FABRICATOR OF WOODWORK SHALL DETERMINE OPTIMUM MOISTURE CONTENT AND REQUIRED TEMPERATURE AND HUMIDITY CONDITIONS. PART2-PRODUCTS 2.01 BASIC MATERIALS AND FABRICATION METHODS A. GENERAL: EXCEPT AS OTHERWISE INDICATED, COMPLY WITH FOLLOWING REQUIREMENTS FOR ARCHITECTURAL WOODWORK NOT SPECIFICALLY INDICATED AS PREFABRICATED OR PRE -FINISHED STANDARD PRODUCTS. B. WOOD MOISTURE CONTENT: PROVIDE KILN -DRIED (KD) LUMBER WITH AN AVERAGE MOISTURE CONTENT RANGE OF 6% TO 11% FOR INTERIOR WORK. MAINTAIN TEMPERATURE AND RELATIVE HUMIDITY DURING FABRICATION, STORAGE AND FINISHING OPERATIONS SO THAT MOISTURE CONTENT VALUES FOR WOODWORK AT TIME OF INSTALLATION DOES NOT EXCEED 5% TO 10%. C. FIRE RETARDANT TREATMENT 1. WHERE FIRE -RETARDANT TREATED LUMBER AND VENEER CORE PLYWOOD ARE REQUIRED, PROVIDE MATERIALS WHICH COMPLY WITH APPLICABLE AWPA STANDARDS FOR PRESSURE IMPREGNATION WITH FIRE -RETARDANT CHEMICALS AND WITH THE FOLLOWING REQUIREMENTS: a. FLAME SPREAD, FUEL CONTRIBUTED AND SMOKE DEVELOPED RATINGS OF 25 OR LESS, WITH NO INCREASE IN FLAME SPREAD AND NO EVIDENCE OF SIGNIFICANT PROGRESSIVE COMBUSTION UPON CONTINUATION OF TEST FOR ADDITIONAL 20 MINUTES. b. USE CURED ORGANIC RESIN SOLUTION FOR FIRE -RETARDANT TREATMENT WHICH IS RELATIVELY INSOLUBLE IN WATER; IS SUITABLE FOR INTERIOR APPLICATIONS; WILL NOT BLEED THROUGH OR OTHERWISE ADVERSELY AFFECT TYPE OF FINISHES INDICATED AND PERMITS MILLING OF LUMBER AFTER TREATMENT AND KILN DRYING BY A TREATMENT OF WOODWORKING PLANT CERTIFIED BY UL. C. KILN -DRY TREATED WOODWORK TO A MAXIMUM MOISTURE CONTENT OF 10% AFTER TREATMENT UNLESS OTHERWISE INDICATED. d. INSPECT EACH PIECE OF LUMBER AND PLYWOOD; DO NOT USE TWISTED, WARPED, BOWED OR OTHERWISE DAMAGED OR DEFECTIVE WOOD. 2. WHERE FIRE -RETARDANT PARTICLEBOARD IS REQUIRED, PROVIDE PANELS WITH FIRE -RETARDANT CHEMICALS INCORPORATED AT TIME OF MANUFACTURE TO ACHIEVE SURFACE -BURNING CHARACTERISTICS OF 25 FOR FLAME SPREAD, 10 FOR FUEL CONTRIBUTED AND 25 FOR SMOKE DEVELOPED WHEN TESTED IN ACCORDANCE WITH ASTM E84. COMPLY WITH ANSI A108.1 FOR GRADE 1-M-1 PANELS WITH DENSITY OF 48 LBSJFT.3 FOR THICKNESSES OF 3/4" AND LESS, 44 LBSJFT.3 FOR THICKNESSES OF 13/16" TO 1-1/4": EXCEPT AS FOLLOWS: a. MODULUS OF RUPTURE AND MODULUS OF ELASTICITY: 1600 PSI AND 350,000 PSI FOR 48 LB. DENSITY; 1300 PSI AND 275,000 PSI FOR 44 LB. DENSITY. b. LINEAR EXPANSION OF 0.50% FOR 44 LB. DENSITY. C. SCREW -HOLDING CAPACITY, FACE AND EDGE: 300 LBS. AND 250 LBS. FOR 48 LB. DENSITY; 250 LBS. AND 175 LBS. FOR 44 LB. DENSITY. A. SOLID WOOD: AWI SECTION 100, GRADE 1 AND AS FOLLOWS: 1. OPAQUE FINISH: ANY HARDWOOD WHICH, WHEN FINISHED, WILL NOT SHOW ANY GRAIN, IMPERFECTION OR OTHER SURFACE DEFECTS WHEN USED WITH THE OPAQUE FINISH SPECIFIED. 2. CONCEALED: ANY HARDWOOD SPECIE, GRADE III PER AWI SECTION 100. E. PANEL PRODUCTS: AWI SECTION 200, VENEER CORE OR PARTICLE CORE PLYWOOD, WITH FACE VENEERS AS INDICATED. 1. TRANSPARENT FINISH: GRADE I PER AWI SECTION 200S-8, CUT AND GRAINING TO MATCH DESIGNER'S SAMPLE. 2. OPAQUE FINISH: ANY SPECIE OF HARDWOOD VENEER OF GRADE II PER AWI SECTION 2005 8 WHICH, WHEN FINISHED, WILL NOT SHOW ANY GRAIN, IMPERFECTION OR OTHER SURFACE DEFECTS WHEN USED WITH THE OPAQUE FINISH SPECIFIED. F. PLASTIC LAMINATE: NEMA STANDARD LD3, COLOR AND FINISH TO MATCH DESIGNER'S SAMPLES. SEE CONTRACT DRAWINGS FOR SPECIFICATIONS. G. MISCELLANEOUS PRODUCTS 1. FASTENERS a. WOOD SCREWS: FS FFS-111, TYPE, SIZE, MATERIAL AND FINISH AS REQUIRED FOR THE CONDITION OF USE. b. NAILS: FS FF -N-105, TYPE, SIZE, MATERIAL AND FINISH AS REQUIRED FOR THE CONDITION OF USE. C. ANCHORS: TYPE, SIZE, MATERIAL AND FINISH AS REQUIRED FOR THE CONDITION OF USE. 2. ADHESIVES a. FOR LAMINAT NG I PLASTIC LAMINATE SURFACE MELAM NE PH S I ENOL -RESIN OR RESORCINOL -RESIN COMPLYING WITH FS MMM-A-181•TYPE G RADE AND CLASS BEST SUITED FOR THE PURPOSE. b. FOR ALL OTHER USES: MOISTURE RESISTANT COMPLYING WITH FS MMM -A-125, TYPE 11, OR MMM -A-188, TYPE 1, II OR III; TYPE BEST SUITED FOR THE PURPOSE. 3. ARCHITECTURAL WOODWORK HARDWARE AS REQUIRED FOR INTENDED FUNCTION AS SPECIFIED IN DRAWINGS OR MINIMUM STANDARD SPECIFICATION BELOW: a. MORTISE DOOR BOLTS: 150 (IVES) b. FLUSH BOLTS: 359 (IVES) C. DRAWER SLIDES: 328 (GRANT) FOR DRAWERS UP TO 50 LBS. 329 (GRANT) FOR DRAWERS UP TO 100 LBS. d. BRACKETS: M686 (GARCY) WITH END CLIPS e. STANDARDS: 649 (GARCY) I. CATCHES: MAGNETIC TYPE (STANLEY) g. PIVOTS: 327 (STANLEY) h. COAT HOOKS: PETER PEPPER PRODUCTS #2040H, POLISHED CHROME I. PULLS: 3" POLISHED CHROME WIRE 2.02 FABRICATION - GENERAL A. PROVIDE STEEL FRAMING AND LUMBER FRAMING FOR ARCHITECTURAL WOODWORK, COMPLETE WITH ALL BRACING AND FASTENING DEVICES AS REQUIRED FOR A RIGID INSTALLATION AND AS REQUIRED TO SUSTAIN THE IMPOSED LOADS. B. DO ALL FABRICATION FROM FIELD MEASUREMENT WITH PROVISION FOR SCRIBING AS REQUIRED TO MEET BUILT-IN CONDITIONS. C. COORDINATE THE WORK OF THIS SECTION WITH THE WORK OF OTHER TRADES. D. FABRICATE UNITS IN LARGEST PRACTICABLE SECTIONS. ASSEMBLE IN THE SHOP FOR TRIAL FIT, DISASSEMBLE FOR SHIPMENT AND REASSEMBLE WITH CONCEALED FASTENERS. E. MAINTAIN RELATIVE HUMIDITY AND TEMPERATURE DURING FABRICATION, STORAGE AND FINISHING OPERATIONS MATCHING THAT OF THE AREAS OF INSTALLATION. F. DETAILS INDICATE THE REQUIRED TYPE AND QUALITY OF CONSTRUCTION. SUBJECT TO ACCEPTANCE BY THE DESIGNER, MODIFICATIONS TO CONFORM TO MANUFACTURER'S STANDARDS WILL BE CONSIDERED PROVIDING THEY COMPLY WITH THE CONTRACT DOCUMENTS AND MAINTAIN THE PROFILES SHOWN. G. REINFORCING SHOWN IS MINIMUM. PROVIDE ADDITIONAL REINFORCING AS REQUIRED TO ENSURE A RIGID ASSEMBLY. EXPOSED SURFACES SHALL BE FREE FROM DENTS, TOOL MARKS, WARPAGE, BUCKLE, GLUE AND OPEN JOINTS OR OTHER DEFECTS AFFECTING SERVICEABILITY OR APPEARANCE. ACCURATELY FIT ALL JOINTS, CORNERS AND MITERS. CONCEAL ALL FASTENERS. MAKE THREADED CONNECTIONS TIGHT SO THAT THREADS ARE ENTIRELY CONCEALED. H. FABRICATE ARCHITECTURAL WOODWORK WITH PRE-CUT OPENINGS, WHERE POSSIBLE, TO RECEIVE HARDWARE, APPLIANCES, PLUMBING FIXTURES, ELECTRICAL WORK AND SIMILAR ITEMS. LOCATE OPENINGS ACCURATELY AND USE TEMPLATES OR ROUGHING -IN DIAGRAMS FOR PROPER SIZE AND SHAPE. SMOOTH EDGES OF CUTOFFS AND, WHERE LOCATED IN COUNTERTOPS AND SIMILAR EXPOSURES, SEAL EDGES OF CUTOUTS WITH A WATER-RESISTANT COATING. 2.03 CASEWORK A. FABRICATE CASEWORK ITEMS TO DESIGN, DETAIL AND DIMENSIONS INDICATED ACCORDING TO AWI SECTION 400, FOR GRADE AND FINI H ND S I ICATED. B. OPAQUE FINISHED CASEWORK SHALL BE AWI PREMIUM GRADE, AND AS FOLLOWS: 1. SOLID WOOD AND PLYWOOD PARTS SHALL BE AS SPECIFIED. 2. FACTORY -FINISH EXPOSED SURFACES IN OPAQUE FINISH AS SPECIFIED BY DESIGNER. 3. FACTORY -FINISH SEMI -EXPOSED SURFACES WITH PRIMER AND ONE COAT OF SEMI -GLOSS ALKYD ENAMEL IN COLOR TO MATCH EXPOSED SURFACES. SAND BETWEEN COATS C. PLASTIC LAMINATE AND MELAMINE CLAD CASEWORK SHALL COMPLY WITH AWI PREMIUM GRADE AND AS FOLLOWS: 1. ALL EXPOSED SURFACES, COUNTER TOPS AND EDGES SHALL BE SPECIFIED HIGH PRESSURE LAMINATE UNLESS INDICATED TO BE MELAMINE. 2. EXCEPT AS OTHERWISE INDICATED, ALL SEMI -EXPOSED SURFACES SHALL BE SURFACED WITH WHITE MELAMINE CABINET LINER AND PAINTED IN FABRICATOR'S STANDARD OPAQUE FINISH, COLOR TO MATCH EXPOSED LAMINATE. 3. ALL SUBSURFACES TO BE CABINET GRADE PLYWOOD FIRE RETARDANT WHICH COMPLIES WITH NYC BUILDING CODE. D. CASEWORK DOORS SHALL BE SOLID CORE. E. PROVIDE CASEWORK HARDWARE AS SHOWN, SCHEDULED OR REQUIRED FOR PROPER OPERATION. 2.04 DOORS A. DOORS - WOOD VENEER: PROVIDE DOORS TO COMPLY WITH AWI SECTION 200, PREMIUM GRADE, TRANSPARENT FINISH AND AS FOLLOWS: 1. FACE VENEERS SHALL BE AS SPECIFIED. 2. CORE CONSTRUCTION SHALL BE PER AWI SPEC. 3. CONTROL SAMPLE TO BE SUBMITTED FOR DESIGNER APPROVAL. B. PRE -MACHINING: PRE -MACHINE DOORS FOR HARDWARE AT THE FACTORY IN ACCORDANCE WITH AWI SECTION 1300-S-2. C. PRE -FINISHING: FACTORY FINISH WITH TRANSPARENT FINISH TO MATCH DESIGNER'S SAMPLE. 2.05 TRIM PANEL TRIM - SOLID: PROVIDE TRIM COMPLYING WITH AWI SECTION 500A, PREMIUM GRADE, AND AS FOLLOWS: A. ALL TRIM SHALL BE AS NOTED ON THE DRAWING DETAILS. B. SOLID WOOD SHALL BE AS SELECTED BY THE DESIGNER C. TRIM SHALL HAVE A TRANSPARENT FINISH. 2.06 FACTORY FINISHING A. OPAQUE FINISH: PROVIDE FINISH COMPLYING WITH AWI FINISH SYSTEM N0.7 PREMIUM G RADE OPA UE CAT Q ALYZED LACQUER SEMI -GLOSS FINISH CO OR L S TO MATCH CONTROL SAMPLES IN THE DESIGNER'S OFF , ICE B. TRANSPARENT FINISH: PROVIDE FINISH COMPLYING WITH AWI FINISH SYSTEM NO.2, PREMIUM GRADE, TRANSPARENT CATALYZED LACQUER, HAND -RUBBED, OPEN PORE EFFECT, TO BE SUBMITTED FOR DESIGNER APPROVAL BEFORE PROCEEDING WITH FINISH. PART 3 - EXECUTION 3.01 PREPARATION A. CONDITION WOODWORK TO AVERAGE PREVAILING HUMIDITY CONDITIONS IN INSTALLATION AREAS PRIOR TO INSTALLING. B. DELIVER INSERTS AND SIMILAR ANCHORING DEVICES TO BE BUILT INTO SUBSTRATES WELL IN ADVANCE OF TIME SUBSTRATES ARE TO BE BUILT. C. PRIOR TO INSTALLATION OF ARCHITECTURAL WOODWORK, EXAMINE SHOP FABRICATED WORK FOR COMPLETION AND COMPLETE WORK AS REQUIRED, INCLUDING BACK PRIMING AND REMOVAL OF PACKING. 3.02 INSTALLATION A. INSTALL THE WORK PLUMB, LEVEL, TRUE AND STRAIGHT WITH NO DISTORTIONS. SHIM AS REQUIRED USING CONCEALED SHIMS. INSTALL TO A TOLERANCE OF 1/8" IN 8'-0" FOR PLUMB AND LEVEL (INCLUDING COUNTERTOPS) AND WITH 1/16" MAXIMUM OFFSET IN FLUSH ADJOINING SURFACE; 1/8" MAXIMUM OFFSETS IN REVEALED ADJOINING SURFACES. B. SCRIBE AND CUT WORK TO FIT ADJOINING WORK AND REFINISH CUT SURFACES OR REPAIR DAMAGED FINISH AT CUTS. C. ANCHOR WOODWORK TO ANCHORS OR BLOCKING BUILT-IN OR DIRECTLY ATTACHED TO SUBSTRATES. SECURE TO GROUNDS, STRIPPING AND BLOCKING WITH COUNTERSUNK, CONCEALED FASTENERS AND BLIND NAILING AS REQUIRED FOR A COMPLETE INSTALLATION. EXCEPT WHERE PRE -FINISHED MATCHING FASTENER HEADS ARE REQUIRED, USE FINE FINISHING NAILS FOR EXPOSED NAILING, COUNTERSUNK AND FILLED FLUSH WITH WOODWORK AND MATCHING FINAL FINISH WHERE TRANSPARENT FINISH IS INDICATED. D. FIRE -RETARDANT WOODWORK: HANDLE, STORE AND INSTALL IN ACCORDANCE WITH MANUFACTURER'S DIRECTIONS AND AS REQUIRED TO MEET REQUIRED CLASSIFICATION OR RATING. PROVIDE SPECIAL FASTENERS, MOLDINGS, ADHESIVES AND OTHER ACCESSORIES AS TESTED AND LISTED FOR TYPE OF FIRE -RETARDANT WOODWORK INDICATED. E. CASEWORK: INSTALL WITHOUT DISTORTION SO THAT DOORS AND DRAWERS WILL FIT OPENINGS PROPERLY AND BE ACCURATELY ALIGNED. ADJUST HARDWARE TO CENTER DOORS AND DRAWERS IN OPENINGS AND TO PROVIDE UNENCUMBERED OPERATION. COMPLETE THE INSTALLATION OF HARDWARE AND ACCESSORY ITEMS AS INDICATED. MAINTAIN VENEER SEQUENCE MATCHING (IF ANY) OF CASEWORK WITH TRANSPARENT FINISH. F. COUNTERTOPS: ANCHOR SECURELY TO BASE UNITS AND OTHER SUPPORT SYSTEMS AS INDICATED, OR AS REQUIRED. G. DOORS 1. DO NOT INSTALL DOORS UNTIL CONCRETE, TILE WORK AND OTHER WET WORK HAS BEEN COMPLETED AND DRIED IN THE AREAS TO RECEIVE DOORS. 2. DOORS SHALL NOT BE SUBJECTED TO ABNORMAL HEAT, DRYNESS OR HUMIDITY. AVOID SUDDEN CHANGES SUCH AS FORCED HEAT (USED TO DRY OUT THE BUILDING). 3. INSTALL DOORS IN REQUIRED OPENINGS AS SHOWN. INSTALL FLUSH PANELS WITH CONCEALED FASTENERS. PROVIDE PILOT HOLES OF PROPER SIZE FOR SCREWS INTO PARTICLE BOARD CORE DOORS. USE STAINLESS STEEL SHEET METAL SCREWS INTO PARTICLEBOARD. 4. APPLY HARDWARE IN ACCORDANCE WITH HARDWARE MANUFACTURER'S INSTRUCTIONS AND "SECTION 08710 - FINISH HARDWARE". ADJUST DOOR INSTALLATIONS TO PROVIDE UNIFORM CLEARANCE AT HEAD AND JAMBS AND TO CONTACT STOPS UNIFORMLY. REMOVE AND REPLACE DOORS WHICH ARE FOUND TO BE WARPED, BOWED, OR OTHERWISE DAMAGED AND CANNOT BE PROPERLY FITTED IN FRAMES. 3.03 ADJUSTMENT, CLEANING FINISHING AND PROTECTION O. REPAIR DAMAGED AND DEFECTIVE WOODWORK WHEREVER POSSIBLE TO ELIMINATE DEFECTS FUNCTIONALLY AND VISUALLY; WHERE NOT POSSIBLE TO REPAIR PROPERLY, REPLACE WOODWORK. ADJUST JOINERY FOR UNIFORM APPEARANCE. P. CLEAN HARDWARE, LUBRICATE AND MAKE FINAL ADJUSTMENTS FOR PROPER OPERATION. Q. CLEAN WOODWORK ON EXPOSED AND SEMI -EXPOSED SURFACES. TOUCH-UP SHOP -APPLIED FINISHES TO RESTORE DAMAGED OR SOILED AREAS. R. INSTALLER OF ARCHITECTURAL WOODWORK SHALL ADVISE CONTRACTOR OF PROCEDURES REQUIRED TO PROTECT ARCHITECTURAL WOODWORK DURING REMAINDER OF CONSTRUCTION PERIOD TO ENSURE THAT WORK WILL BE WITHOUT DAMAGE OR DETERIORATION AT TIME OF ACCEPTANCE BY OWNER. END OF SECTION 06400 SECTION 07250 - SPRAYED -ON FIREPROOFING PART 1 - GENERAL 1.01 SUMMARY OF WORK A. THE WORK OF THIS SECTION INCLUDES, BUT IS NOT NECESSARILY LIMITED TO THE FOLLOWING: 1. FIREPROOFING NEW STRUCTURAL STEEL 2. PATCHING EXISTING FIREPROOFING AS REQUIRED 1.02 QUALITY ASSURANCE A. SINGLE SOURCE RESPONSIBILITY: OBTAIN SPRAYED -ON FIREPROOFING MATERIALS FROM A SINGLE MANUFACTURER FOR EACH DIFFERENT PRODUCT. B. F R P I E ERFORMAN CE CHARACTERISTICS: PROVIDE MATERIALS AND CONSTRUCTION WHICH ARE IDENTICAL TO THOSE TESTED FOR THE FOLLOWING FIRE PERFORMANCE CHARACTERISTICS, ACCORDING TO TEST METHOD INDICATED, BY UL OR OTHER TE T S ING AND INSPECTING AGENCY ACCEPTABLE TO AUTHORITIES HAVING JURISDICTION AND COMPLYING WITH RE UIREM Q ENTS OF THE APPLICABLE BUILDING CODES. 1. FIRE RESISTANCE RATINGS: AS INDICATED BY REFERENCE TO DESIGN DESIGNATION IN UL "FIRE RESISTANCE DIRECTORY" FOR FIRE -RATED ASSEMBLIES IN WHICH SPRAYED -ON FIREPROOFING SERVES AS DIRECT -APPLIED PROTECTION, TESTED PER ASTM E119. 2. SURFACE BURNING CHARACTERISTICS: AS INDICATED FOR EACH SPRAYED -ON FIREPROOFING PRODUCT REQUIRED, TESTED PER ASTM E84 AND LISTED IN UL "BUILDING MATERIALS DIRECTORY." 3. TWO-HOUR RATING: MINIMUM FIRE RESISTANCE RATING SHALL BE TWO (2) HOURS UNLESS OTHERWISE INDICATED ON THE DRAWINGS. 1.03 SUBMITTALS A. PRODUCT DATA: SUBMIT MANUFACTURER'S PRODUCT DATA FOR EACH SPRAYED -ON FIREPROOFING PRODUCT INDICATED. B. TEST REPORTS: SUBMIT THE FOLLOWING TEST REPORTS: 1. CERTIFIED TEST RESULTS FORM AN INDEPENDENT TESTING LABORATORY INDICATING COMPLIANCE OF SPRAYED -ON FIREPROOFING PRODUCTS WITH PERFORMANCE REQUIREMENTS INDICATED, INCLUDING ASBESTOS CONTENT WHERE APPLICABLE. 2. TEST RESULTS OF IN-PLACE PERFORMANCE AS REQUIRED UNDER PART 3 OF THIS SECTION FOR FIELD QUALITY CONTROL. C. CERTIFICATES: SUBMIT THE FOLLOWING CERTIFICATES: 1. WHERE PRIMERS ARE APPLIED TO STEEL, SUBMIT STATEMENT FROM PRIMER MANUFACTURERS, CERTIFYING THAT PRIMERS ARE COMPATIBLE WITH SPRAYED -ON FIREPROOFING AND WILL NOT IMPAIR ITS PERFORMANCE UNDER FIRE EXPOSURE FOR APPLICATIONS INDICATED AS PROVED BY ASTM E119 TEST. INCLUDE TEST AND OTHER DATA AS EVIDENCE: DISTRIBUTE DATA TO SPRAYED -ON FIREPROOFING MANUFACTURER. 2. ACCEPTANCE OF STEEL PRIMERS BY SPRAYED -ON FIREPROOFING MANUFACTURER, BASED ON DATA SUBMITTED BY PRIMER MANUFACTURER. 3. SPRAYED- N O FIREP ROOF ING MA NUFA T C URERS' CERTIFICATION THAT THEIR PRODUCTS COMPLY WITH SPECIFICATION REQUIREMENTS AND ARE SUITABLE FOR THE USE INDICATED. 1.04 DELIVERY, HANDLING AND STORAGE A. DELIVER PRODUCTS TO PROJECT SITE IN ORIGINAL, UNOPENED PACKAGES WITH MANUFACTURERS' LABELS IDENTIFYING PRODUCTS LEGIBLE AND INTACT. INCLUDE ON LABEL, NAME OF PRODUCT, MANUFACTURER'S NAME, DATE OF MANUFACTURE AND SHELF LIFE, WHERE APPLICABLE. ALSO INCLUDE UL LABELS FOR FIRE -RESISTANCE RATINGS APPLICABLE TO PROJECT. B. USE MATERIALS WITH LIMITED SHELF LIFE WITHIN PERIOD INDICATED. REMOVE FROM PROJECT SITE AND DISCARD ANY MATERIALS WHOSE SHELF LIFE HAS EXPIRED. C. STORE MATERIALS INSIDE, UNDER COVER, ABOVE GROUND AND IN A MANNER TO KEEP THEM DRY UNTIL READY TO USE. REMOVE FROM PROJECT SITE AND DISCARD ANY MATERIALS THAT HAVE BEEN EXPOSED TO MOISTURE OR HAVE OTHERWISE DETERIORATED. 1.05 ENVIRONMENTAL CONDITIONS DO NOT INSTALL SPRAYED -ON FIREPROOFING WHEN AMBIENT OR SUBSTRATE TEMPERATURES ARE 40OF (4.40C) AND FALLING, UNLESS TEMPORARY PROTECTION AND HEAT CAN BE PROVIDED TO MAINTAIN TEMPERATURES OF BOTH AT OR ABOVE THIS TEMPERATURE LEVEL FOR 24 HOURS BEFORE, DURING AND AFTER APPLICATION OF SPRAYED FIREPROOFING. VENTILATE SPRAY FIREPROOFING BY MEANS OF NATURAL OR, WHERE THIS IS INADEQUATE, FORCED AIR CIRCULATION DURING AND AFTER APPLICATION UNTIL IT THOROUGHLY DRIES. 1.06 SEQUENCING SCHEDULE AND COORDINATE APPLICATION OF SPRAYED -ON FIREPROOFING WITH OTHER, RELATED WORK SPECIFIED IN OTHER SECTIONS TO COMPLY WITH TH E FOLLOW ING REQUIREMENTS: A. PREVENT DETERIORATION OF SPRAYED -FIREPROOFING FOR INTERIOR APPLICATIONS DUE TO EXPOSURE TO UNFAVORABLE ENVIRONMENTAL CONDITIONS. B. AVOID UNNECESSARY EXPOSURE OF SPRAYED -ON FIREPROOFING TO ABRASION AND OTHER DAMAGE LIKELY TO OCCUR DURING CONSTRUCTION OPERATIONS SUBSEQUENT TO ITS APPLICATION. C. ENSURE THAT SPRAYED -FIREPROOFING IS INSTALLED PRIOR TO INSTALLATION OF ENCLOSING OR CONCEALING WORK, WITH SUFFICIENT TIME ALLOWED FOR INSPECTION, TESTING AND CORRECTION OF DEFECTIVE FIREPROOFING. PART2-PRODUCTS 2.01 SPRAYED -ON FIREPROOFING MATERIALS A. GENERAL: PROVIDE MANUFACTURER'S STANDARD PRODUCTS COMPLYING WITH REQUIREMENTS INDICATED BELOW FOR MATERIAL COMPOSITION AND PHYSICAL PROPERTIES REPRESENTATIVE OF INSTALLED PRODUCTS. B. MATERIAL COMPOSITION SHALL BE ONE OF THE FOLLOWING: 1. CEMENTITIOUS FIREPROOFING: FACTORY -MIXED DRY FORMULATION OF INORGANIC BINDERS AND LIGHTWEIGHT MINERAL AGGREGATES MIXED WITH WATER AT PROJECT SITE TO FORM A SLURRY FOR PUMPING AND FOR DISPERSAL BY COMPRESSED AIR INTRODUCED AT SPRAY NOZZLE. 2. MINERAL FIBER FIREPROOFING: FACTORY -MIXED DRY FORMULATION OF INORGANIC BINDERS, MINERAL FIBERS, FILLERS AND ADDITIVES FOR SPRAYED -ON APPLICATION BY CONVEYING DRY MIXTURE BY LOW PRESSURE AIR THROUGH HOSE AND MIXING IT WITH WATER AT SPRAY NOZZLE. C. PHYSICAL PROPERTIES: MINIMUM VALUES, UNLESS OTHERWISE INDICATED, MEASURED PER STANDARD TEST METHODS REFERENCED WITH EACH PROPERTY, AS FOLLOWS: 1. BOND STRENGTH: 80 LBS./IN.2 PER ASTM E736. 2. COMPRESSIVE STRENGTH: 3.47 LBS./IN.2 PER ASTM E761. 3. CORROSION RESISTANCE: NO EVIDENCE OF CORROSION PER ASTM E937. 4. DEFLECTION: NO CRACKING, SPALLING, DELAMINATION OR THE LIKE PER ASTM E759. 5. EFFECT OF IMPACT ON BONDING: NO CRACKING, SPALLING DELAMINATION OR THE LIKE PER ASTM E760. 6. AIR EROSION: MAXIMUM WEIGHT LOSS OF 0.025 GRAMS/FT.2 PER ASTM E859. 7. DRY DENSITY: VALUES FOR AVERAGE AND INDIVIDUAL DENSITIES AS REQUIRED FOR FIRE -RESISTANCE RATING INDICATED PER ASTM E605, BUT NOT LESS THAN THE FOLLOWING: a. FOR CEMENTITIOUS FIREPROOFING: 14 LBSJFT.3 b. FOR MINERAL FIBER FIREPROOFING: 13 LBSJFT.3 8. HARDNESS: 0.50" MAXIMUM PENETRATION PER ASTM C569. 9. SURFACE BURNING CHARACTERISTICS: MAXIMUM FLAME SPREAD AND SMOKE DEVELOPED VALUES OF 10 AND 0, RESPECTIVELY. D. SUBJECT TO COMPLIANCE WITH REQUIREMENTS, PROVIDE ONE OF THE FOLLOWING: 1. CEMENTITIOUS FIREPROOFING: "MONOKOTE", GRACE CONSTRUCTION PRODUCTS DIVISION, W.R. GRACE & COMPANY. 2. MINERAL FIBER FIREPROOFING: "CAFCO BLAZE -SHIELD", UNITED STATES MINERAL PRODUCTS COMPANY. 2.02 AUXILIARY FIREPROOFING MATERIALS A. GENERAL: PROVIDE AUXILIARY FIREPROOFING MATERIALS WHICH ARE COMPATIBLE WITH SPRAYED -ON FIREPROOFING PRODUCTS AND SUBSTRATES, APPROVED FOR USE INDICATED BY MANUFACTURER OF SPRAYED -ON FIREPROOFING AND WHICH HAVE BEEN APPROVED BY UL OR OTHER ACCEPTABLE TESTING AND INSPECTING AGENCY FOR USE IN FIRE -RESISTANCE RATED DESIGNS INDICATED. B. SUBSTRATE PRIMERS: TYPE APPROVED BY MANUFACTURER OF SPRAYED -ON FIREPROOFING FOR SUBSTRATE AND FOR CONDITIONS OF EXPOSURE INDICATED. C. ADHESIVE FOR BONDING FIREPROOFING: TYPE RECOMMENDED BY MANUFACTURER OF SPRAYED -ON FIREPROOFING MANUFACTURER. D. METAL LATH: EXPANDED METAL LATH FABRICATED FROM MATERIAL OF WEIGHT, CONFIGURATION AND FINISH REQUIRED TO COMPLY WITH FIRE -RESISTANCE RATED DESIGNS INDICATED AND FIREPROOFING MANUFACTURER'S RECOMMENDATIONS. INCLUDE CLIPS, LATHING ACCESSORIES AND OTHER ANCHORAGE DEVICES REQUIRED TO ATTACH LATH TO SUBSTRATES. E. TOPCOATS: TYPE AS RECOMMENDED BY MANUFACTURER OF EACH FIREPROOFING MATERIAL REQUIRED FOR APPLICATIONS INDICATED. F. SEALER FOR MINERAL -FIBER FIREPROOFING: CLEAR -DRYING WATER-DISPERSABLE PROTECTIVE COATING RECOMMENDED BY MINERAL FIBER FIREPROOFING MANUFACTURER. PRODUCT: SUBJECT TO COMPLIANCE WITH REQUIREMENTS, PROVIDE "CAFCO BOND -SEAL" BY UNITED STATES MINERAL PRODUCTS COMPANY. PART 3 - EXECUTION 3.01 INSPECTION A. REQUIRE INSTALLER TO EXAMINE SUBSTRATES TO DETERMINE IF THEY ARE IN SATISFACTORY CONDITION TO RECEIVE SPRAYED -ON FIREPROOFING. A SATISFACTORY SUBSTRATE IS DEFINED AS FOLLOWS: 1. SUBSTRATE COMPLIES WITH REQUIREMENTS OF THE SECTION IN WHICH THE SUBSTRATE AND RELATED WORK IS SPECIFIED AND IS FREE OF OIL, GREASE, ROLLING COMPOUNDS, INCOMPATIBLE PRIMERS, LOOSE MILL SCALE, DIRT OR OTHER FOREIGN SUBSTANCES CAPABLE OF IMPAIRING BOND OF FIREPROOFING WITH SUBSTRATE UNDER CONDITIONS OF NORMAL USE OR FIRE EXPOSURE. 2. OBJECTS WHICH WILL PENETRATE FIREPROOFING, INCLUDING CLIPS, HANGERS, SUPPORT SLEEVES AND SIMILAR ITEMS HAVE BEEN SECURELY ATTACHED TO SUBSTRATES. 3. SUBSTRATES ARE NOT OBSTRUCTED BY DUCTS, PIPING, EQUIPMENT AND OTHER SUSPENDED CONSTRUCTION THAT COULD INTERFERE WITH APPLICATION OF FIREPROOFING. B. FOR STEEL OR OTHER SUBSTRATES SUSPECTED OF BEING COATED WITH OIL, ROLLING COMPOUNDS OR OTHER SUBSTANCES NOT READILY IDENTIFIABLE BUT POTENTIALLY CAPABLE OF IMPAIRING BOND, CONDUCT TESTS RECOMMENDED BY FIREPROOFING MANUFACTURER TO DETERMINE THEIR PRESENCE AND EFFECT ON ADHESION OF FIREPROOFING. C. DO NOT PROCEED WITH INSTALLATION OF FIREPROOFING UNTIL UNSATISFACTORY CONDITIONS HAVE BEEN CORRECTED. 3.02 PREPARATION A. CLEAN SUBSTRATES OF SUBSTANCES WHICH COULD IMPAIR BOND OF FIREPROOFING, INCLUDING OIL, GREASE, ROLLING COMPOUNDS, INCOMPATIBLE PRIMERS AND LOOSE MILL SCALE. B. PRIME SUBSTRATES WHERE RECOMMENDED BY FIREPROOFING MANUFACTURER, EXCEPT WHERE COMPATIBLE SHOP PRIMER HAS BEEN APPLIED AND IS IN SATISFACTORY CONDITION TO RECEIVE FIREPROOFING. C. FOR EXPOSED SPRAYED -ON FIREPROOFING APPLICATIONS REPAIR SUBSTRATES TO REMOVE ANY SURFACE IMPERFECTIONS THAT COULD AFFECT UNIFORMITY OF TEXTURE AND THICKNESS IN FINISHED SURFACE OF FIREPROOFING. D. REMOVE MINOR PROJECTIONS AND FILL VOIDS WHICH WOULD TELEGRAPH THROUGH. E. COVER OTHER WORK AND EXISTING IMPROVEMENTS WHICH MIGHT BE DAMAGED BY FALL -OUT OR OVER -SPRAY OF FIREPROOFING MATERIALS DURING APPLICATION. PROVIDE TEMPORARY ENCLOSURE AS REQUIRED TO CONFINE SPRAYING OPERATIONS, PROTECT THE ENVIRONMENT AND TO ENSURE ADEQUATE AMBIENT CONDITIONS FOR TEMPERATURE AND VENTILATION. 3.03 INSTALLATION A. COMPLY WITH FIREPROOFING MANUFACTURER'S INSTRUCTIONS FOR MIXING MATERIALS, FOR APPLICATION PROCEDURES AND FOR TYPES OF EQUIPMENT USED TO CONVEY AND SPRAY ON FIREPROOFING MATERIAL; AS APPLICABLE TO THE PARTICULAR CONDITIONS OF INSTALLATION AND AS REQUIRED TO ACHIEVE FIRE -RESISTANCE RATINGS INDICATED. B. COAT SUBSTRATES WITH ADHESIVE PRIOR TO APPLICATION OF FIREPROOFING WHERE REQUIRED TO ACHIEVE FIRE -RESISTANCE RATING OR RECOMMENDED BY FIREPROOFING MANUFACTURER FOR MATERIAL AND APPLICATION INDICATED. C. INSTALL METAL LATH AS REQUIRED TO COMPLY WITH FIRE RESISTANCE RATINGS AND RECOMMENDATIONS OF FIREPROOFING MANUFACTURE R FOR CONDITIONS OF EXPOSURE AND INTENDED USE. SECURELY ATTACH LATH TO SUBSTRATE IN POSITION REQUIRED FOR FIRE -RESISTANCE RATING INDICATED AND TO SUPPORT AS WELL AS TO REINFORCE FIREPROOFING, USING ANCHORAGE DEVICES OF TYPE RECOMMENDED BY FIREPROOFING MANUFACTURER. ATTACH LATHING ACCESSORIES WHERE INDICATED OR REQUIRED. D. INSTALL REINFORCING FABRIC WHERE REQUIRED. E. EXTEND FIREPROOFING FULL THICKNESS OVER ENTIRE AREA OF EACH SUBSTRATE TO BE PROTECTED. UNLESS OTHERWISE RECOMMENDED BY FIREPROOFING MANUFACTURER, INSTALL BODY OF FIREPROOF COVERING IN A SINGLE COURSE. F. APPLY FIREPROOFING IN THICKNESSES LESS THAN THAT REQUIRED TO ACHIEVE FIRE RESISTANCE RATINGS SPECIFIED. G. APPLY FIREPROOFING MATERIALS BY SPRAYED -ON METHOD TO MAXIMUM EXTENT POSSIBLE. FOLLOWING SPRAYING OPERATION IN EACH AREA, COMPLETE THE COVERAGE BY TROWEL APPLICATION OR OTHER PLACEMENT METHOD ACCEPTABLE TO MANUFACTURER. H. APPLY SEALER AND TOP COAT TO SPRAYED -ON FIREPROOFING WHERE RECOMMENDED BY THE MANUFACTURER. 3.04 FIELD QUALITY CONTROL A. OWNER WILL EMPLOY AND PAY AN INDEPENDENT TESTING LABORATORY TO PERFORM TESTS REQUIRED FOR LOCAL AUTHORITY APPROVAL. B. MAKE PORTIONS OF THE WORK AVAILABLE TO THE OWNER'S TESTING AGENCY AS REQUIRED FOR TESTING. C. REPAIR OR REPLACE FIREPROOFING WITHIN AREAS WHERE TEST RESULTS INDICATE FIREPROOFING DOES NOT COMPLY WITH CODE REQUIREMENTS. 3.05 CLEANING, REPAIR AND PROTECTION A. IMMEDIATELY UPON COMPLETION OF SPRAYING OPERATIONS IN EACH CONTAINABLE AREA OF PROJECT, REMOVE OVER -SPRAY AND FALL -OUT OF MATERIALS FROM SURFACES OF OTHER WORK AND CLEAN EXPOSED SURFACES TO REMOVE EVIDENCE OF SOILING. B. CURE EXPOSED E C MENTITIOUS FIREPROOFING MATERIALS IN COMPLIANCE WITH FIREPROOFING MANUFACTURERS' RECOMMENDATIONS TO PREVENT PREMATURE DRYING. C. PROTECT FIREPROOFING ACCORDING TO ADVICE OF FIREPROOFING MANUFACTURER AND INSTALLER FROM DAMAGE RESULTING FROM CONSTRUCTION OPERATIONS OR OTHER CAUSES SO THAT FIREPROOFING WILL BE WITHOUT DAMAGE OR DETERIORATION AT TIME OF SUBSTANTIAL COMPLETION. D. COORDINATE I NSTALLATION OF FIR EPROOFING WITH OTHE R WORK IN ORD ER TO MINIMIZE TH E NEED FOR OTHER T RADES TO CUT OR REMOVE FIREPROOFING. AS OTHER TRADES SUCCESSIVELY COMPLETE INSTALLATION OF THEIR WORK, MAINTAIN PROTECTION OF STRUCTURE AFFORDED BY FIREPROOFING BY PATCHING ANY AREAS WHICH HAVE BEEN REMOVED OR DAMAGED PRIOR TO CONCEALMENT OF FIREPROOFING BY OTHER WORK. E. REPAIR OR REPLACE WORK WHICH HAS NOT BEEN SUCCESSFULLY PROTECTED. END OF SECTION 07250 SECTION 07920 - JOINT SEALANTS PART1- GENERAL 1.1 SECTION REQUIREMENTS A. SUBMITTALS: PRODUCT DATA AND COLOR SAMPLES. PART2- PRODUCTS 2.1 JOINT SEALANTS A. COMPATIBILITY: PROVIDE JOINT SEALANTS, JOINT FILLERS, AND OTHER RELATED MATERIALS THAT ARE COMPATIBLE WITH ONE ANOTHER AND WITH JOINT SUBSTRATES UNDER SERVICE AND APPLICATION CONDITIONS. B. ELASTOMERIC SEALANTS: COMPLY WITH ASTM C 920. 1. SINGLE -COMPONENT, MILDEW -RESISTANT SILICONE SEALANT, TYPE S; GRADE NS; CLASS 25; USES NT, G, A, AND O; FORMULATED WITH FUNGICIDE. USE FOR INTERIOR SEALANT JOINTS IN CERAMIC TILE, STONE, AND OTHER HARD SURFACES IN KITCHENS AND TOILET ROOMS AND AROUND PLUMBING FIXTURES. C. LATEX SEALANT: SINGLE -C OMPONEN T NONSAG M - ILDEW RESISTANT P AINTABLE, ACRYLIC -EMULSION SEALANT COMPLYING WITH ASTM C 834. FOR INTERIOR USE ONLY AT PERIMETERS OF DOOR AND WINDOW FRAMES. D. ACOUSTICAL SEALANT FOR EXPOSED JOINTS: NONSAG, PAINTABLE, NONSTAINING, LATEX SEALANT COMPLYING WITH ASTM C 834. FOR INTERIOR USE ONLY AT ACOUSTICAL ASSEMBLIES. E. ACOUSTICAL SEALANT FOR CONCEALED JOINTS: NONDRYING, NONHARDENING, NONSKINNING, NONSTAINING, GUNNABLE, SYNTHETIC -RUBBER SEALANT RECOMMENDED FOR SEALING INTERIOR CONCEALED JOINTS TO REDUCE TRANSMISSION OF AIRBORNE SOUND. FOR INTERIOR USE ONLY AT ACOUSTICAL ASSEMBLIES. PART 3 - EXECUTION 3.1 INSTALLATION A. COMPLY WITH ASTM C 1193. B. COMPLY WITH ASTM C 919 FOR USE OF JOINT SEALANTS IN ACOUSTICAL APPLICATIONS. END OF SECTION 07920 SECTION 08100 - STEEL DOORS AND FRAMES PART1-GENERAL 1.01 SUMMARY OF WORK A. THE WORK OF THIS SECTION INCLUDES, BUT IS NOT NECESSARILY LIMITED TO, THE FOLLOWING: STEEL DOORS AND FRAMES B. RELATED WORK SPECIFIED ELSEWHERE 1. FINISH HARDWARE - SEE SECTION 08710. 2. PAINTING - SEE SECTION 09900. 1.02 SUBMITTALS A. PRODUCT DATA: SUBMIT MANUFACTURER'S SPECIFICATIONS FOR FABRICATION AND INSTALLATION, INCLUDING DATA SUBSTANTIATING THAT PRODUCTS COMPLY WITH SPECIFIED REQUIREMENTS. B. SHOP DRAWINGS: SUBMIT SHOP DRAWINGS FOR THE FABRICATION AND INSTALLATION OF STEEL DOORS AND FRAMES. INCLUDE DETAILS OF EACH FRAME TYPE, ELEVATIONS OF DOOR DESIGN TYPES, CONDITIONS AT OPENINGS, DETAILS OF CONSTRUCTION, FINISH, LOCATION AND INSTALLATION REQUIREMENTS OF FINISH HARDWARE AND REINFORCEMENTS AND DETAILS OF JOINTS AND CONNECTIONS. PROVIDE A SCHEDULE OF DOORS AND FRAMES USING SAME REFERENCE NUMBERS FOR DETAILS AND OPENINGS AS THOSE ON THE CONTRACT DRAWINGS. 1.03 DELIVERY, STORAGE AND HANDLING A. DELIVER S TEEL DOORS AND FRAMES CRA TED TO PROVIDE PROTECTION U D RING TRANSIT AND JOB STORA GE. B. INSPECT STEEL DOORS AND FRAMES UPON DELIVERY FOR DAMAGE. MINOR DAMAGES MAY BE REPAIRED PROVIDED THE FINISH ITEMS ARE EQUAL IN ALL RESPECTS TO NEW WORK AND ACCEPTABLE TO THE DESIGNER; OTHERWISE, REMOVE AND REPLACE DAMAGED ITEMS AS DIRECTED. PART2-PRODUCTS 2.01 MATERIALS A. HOT -ROLLED STEEL SHEETS AND STRIPS: COMMERCIAL QUALITY CARBON STEEL, PICKLED AND OILED, COMPLYING WITH ASTM A569. B. COLD -ROLLED STEEL SHEETS: COMMERCIAL QUALITY CARBON STEEL, COMPLYING WITH ASTM A366. C. REINFORCEMENT STEEL: ASTM A36 D. FILLER: SOUND DEADENING AND HEAT -RETARDING MINERAL FIBER INSULATING MATERIAL. E. FASTENERS: GALVANIZED OR CADMIUM -PLATED STEEL. 1. BOLTS AND NUTS: ASTM A307, GRADE A. 2. EXPANSION BOLTS: FS FF -S-0325, GROUP III, EXPANSION SHIELD (SELF -DRILLING TUBULAR EXPANSION SHELL BOLT ANCHORS), TYPE 1 OR 2. 3. MACHINE SCREWS: FS FF -S-92, CARBON STEEL, TYPE III CROSS -RECESSED, DESIGN I OR II RECESS, STYLE 2C FLAT HEAD. F. SHOP PRIMER: ONE OF THE FOLLOWING, BAKED ON: FS TT -P57 (TYPE II) OR FS TT -P-659. 2.02 FABRICATION A. FABRICATE DOORS AND FRAMES TO THE DESIGN AND DIMENSIONS SHOWN IN ACCORDANCE WITH BEST SHOP PRACTICES. UNLESS OTHERWISE SHOWN, FABRICATE DOORS AND PANELS TO A THICKNESS OF 1-3/4". TAKE FIELD MEASUREMENTS AS NEEDED WHEN COORDINATING WITH ADJOINING WORK. B. MAKE DOORS AND FRAMES STRONG, RIGID, NEAT IN APPEARANCE AND FREE FROM DEFECTS. REINFORCE CORNERS OF DOORS AS REQUIRED TO PREVENT TWISTING OR SAGGING. C. FORM EXPOSED SURFACES FREE FROM WARP WAVE AND BUCKLE WITH AL1 CORNERS SQUARE UN LESS OTHERWISE SHOWN. FORM MOLDED MEMBERS STRAIGHT AND TRUE, WITH WELDED JOINTS COPED OR MITERED, WELL FORMED AND IN TRUE ALIGNMENT. DRESS WELDED JOINTS ON EXPOSED SURFACES SMOOTH SO THEY ARE INVISIBLE AFTER FINISHING. D. PROVIDE CLEARANCES FOR DOORS NOT OTHERWISE SPECIFIED AS FOLLOWS: 1/8" AT JAMBS AND HEADS, 1/8" AT MEETING STILES OF PAIRS OF DOORS AND 3/8" AT BOTTOM WHERE NO SADDLE OR CARPET IS REQUIRED. WHERE A SADDLE IS SHOWN, PROVIDE 1/4" CLEARANCE ABOVE THE THRESHOLD. WHERE CARPET IS SHOWN, PROVIDE 1/4" CLEARANCE ABOVE THE CARPET. E. BEVEL LOCK EDGE 1/8" IN 2" FOR DOORS. F. MORTISE, REINFORCE, DRILL AND TAP DOORS AT FACTORY TO RECEIVE MORTISE -TYPE HARDWARE IN ACCORDANCE WITH REVIEWED HARDWARE SCHEDULE AND TEMPLATES. PROVIDE REINFORCING, DRILL AND TAP FOR DOORS TO RECEIVE SURFACE APPLIED HARDWARE. AT PUSH PLATES AND KICK -PLATES, PROVIDE REINFORCING ONLY. USE STEEL SECURED BY SPOT WELDING AS REINFORCEMENT. REINFORCE AS FOLLOWS: 1. HINGES: 7 GAUGE AND SIZE, AS REQUIRED BY APPROVED HARDWARE MANUFACTURER. 2. LOCK FRONTS: 14 GAUGE AND SIZE, AS REQUIRED BY APPROVED HARDWARE MANUFACTURER. 3. LOCK: 12 GAUGE AND SIZE, AS REQUIRED BY APPROVED HARDWARE MANUFACTURER. 4. CLOSER: 12 GAUGE ONE-PIECE CHANNEL AND SIZE, AS REQUIRED BY APPROVED HARDWARE MANUFACTURER. 5. OTHER HARDWARE REINFORCEMENTS, AS REQUIRED FOR ADEQUATE STRENGTH AND ANCHORAGE. 6. IN LIEU OF REINFORCEMENT SPECIFIED, HARDWARE MANUFACTURERS' RECOMMENDED REINFORCING UNITS MAY BE USED. G. FRAME SHALL BE FULLY MITERED AND CONTINUOUSLY WELDED AT FRAME CORNERS AND STOPS, WITH EDGES STRAIGHT AND TRUE. GRIND WELDS SMOOTH AND FLUSH ON EXPOSED SURFACES. H. ACCURATELY MACHINE, FILE AND FIT EXPOSED CONNECTIONS WITH HAIRLINE JOINTS UNLESS OTHERWISE SHOWN. 1. CONCEAL FASTENERS WHEREVER POSSIBLE. COUNTERSINK EXPOSED SCREWS USING FLAT, PHILLIPS HEAD SCREWS. J. PROVIDE WELDS OF ADEQUATE STRENGTH AND DURABILITY. 2.03 FLUSH DOORS A. CONSTRUCT DOORS WITH 18 GAUGE FACE SHEETS WITH EDGES WELDED AND FINISHED FLUSH. DO NOT EXPOSE SEAMS OR JOINTS ON DOOR FACES OR EDGES. REINFORCE FACE SHEETS WITH 20 GAUGE INTERLOCKING VERTICAL C OR ZSHAPED REINFORCING MEMBERS SPACED NOT OVER 6" APART AND SPOT WELDED TO FACE SHEETS. PLACE FILLER BETWEEN REINFORCING MEMBERS. PROVIDE REMOVABLE MOLDINGS OF 18 GAUGE STEEL FOR GLAZED OPENINGS IN DOORS APPLIED WITH COUNTERSUNK SCREWS SPACED NOT MORE THAN 12" O.C. B. OPTIONAL FRAMING FOR CORE: A CONTINUOUS TRUSS FORMED INNER CORE OF SHEET METAL, NOT LIGHTER THAN 28 GAUGE, SPOT WELDED TO THE FACE SHEETS EVERY 2-3/4" HORIZONTALLY AND 3" VERTICALLY OVER THE ENTIRE SURFACE OF BOTH FACES. 2.04 STEEL DOOR FRAMES A. PROVIDE FULLY WELDED, COMBINATION TYPE FRAMES, TO BE USED AS BOTH DOOR BUCK AND TRIM, FORMED TO PROFILES SHOWN AND, UNLESS OTHERWISE SHOWN, OF 16 GAUGE STEEL. B. FABRICATE ANCHORS OF STEEL NO LIGHTER THAN THE GAUGE USED FOR THE FRAME, 2-1/2" WIDE BY 10" LONG, THREE (3) PER JAMB UP TO T HIGH AND FOUR 4 PER JAMB OVER 7' HIGH. C. WHERE FRAMES ARE SET INTO DRYWALL STEEL STUD WALLS, WELD 16 GAUGE ANCHOR CLIPS 2' O.C. TO EACH JAMB AND HEAD. ANCHOR CLIPS SHALL MATCH THE SIZE AND TYPE OF STUD USED IN EACH WALL. D. PROVIDE 16 GAUGE STEEL CHANNEL TEMPORARY SPREADERS AT THE BOTTOM OF ALL THREE -SIDED FRAMES TO PREVENT DISTORTION DURING SHIPMENT AND STORAGE AND TO HOLD FRAMES IN PROPER POSITION UNTIL ANCHORAGE AND ADJACENT CONSTRUCTION HAVE BEEN COMPLETED. E. TERMINATE BOTTOM OF FRAMES AT THE INDICATED FINISHED FLOOR LEVEL. WHERE FLOOR FILL OR SETTING BEDS OCCUR, SUPPORT FRAME BY ADJUSTABLE CLIP ANGLES ANCHORED TO THE STRUCTURAL SUBSTRATE. ANGLE FLOOR CLIPS SHALL BE 12 GAUGE, WELDED TO FRAME AND PUNCHED FOR TWO (2) 3/8" FASTENERS. F. MORTISE, REINFORCE, DRILL AND TAP FRAMES FOR MORTISE -TYPE HARDWARE. FOR SURFACE MOUNTED HARDWARE, PROVIDE INTERNAL REINFORCEMENT WHICH IS TO BE FIELD DRILLED AND TAPPED. LOCATE HARDWARE IN FRAMES TO MATCH LOCATION SHOWN OR SPECIFIED FOR DOORS AND IN ACCORDANCE WITH APPROVED HARDWARE SCHEDULE AND TEMPLATES. PROVIDE THE FOLLOWING: 1. HINGE REINFORCEMENTS: 7 GAUGE AND SIZE, AS REQUIRED BY APPROVED HARDWARE MANUFACTURER. 2. STRIKE REINFORCEMENTS: 7 GAUGE AND SIZE, AS REQUIRED BY APPROVED HARDWARE MANUFACTURER. 3. CLOSER AND HOLDER REINFORCEMENT: 12 GAUGE AND SIZE, AS REQUIRED BY APPROVED HARDWARE MANUFACTURER. 4. COVER BOXES: FULLY ENCLOSING STEEL COVER BOXES SHALL BE PROVIDED OVER ALL MORTISES. PROVIDE REMOVABLE ACCESS PLATES IN THE HEADS OF FRAMES TO RECEIVE CONCEALED DOOR CLOSERS. OFFSET REINFORCEMENT SO THAT FACES OF HINGES OR KEEPERS ARE FLUSH WITH FACE OF THE FRAME REBATE. 5. HOLES FOR SILENCERS: PROVIDE THREE 3 FOR SINGLE DOORS AND TWO 2 FOR PAIRS () () OF DOORS. INSTALL PLASTIC PLUGS IN SILENCER HOLES TO KEEP HOLES CLEAR DURING INSTALLATION. 2.05 SHOP PAINTING A. CLEAN, TREAT AND PAINT SURFACES OF FABRICATED DOOR AND WINDOW WORK INSIDE AND OUT, WHETHER EXPOSED OR CONCEALED IN THE CONSTRUCTION. B. THOROUGHLY CLEAN METAL SURFACES OF LOOSE SCALE SHAVINGS FILINGS DIRT AND OTHER DELETERIOUS MATERIALS BY USE OF WIRE BRUSHES OR OTHER EFFECTIVE MEANS. REMOVE GREASE AND OIL BY ONE OF THE METHODS SPECIFIED IN SSPC-SP-1-63 "SOLVENT CLEANING." FILL SEAMS IN EDGES, AS REQUIRED. C. APPLY TWO (2) COATS OF METAL PRIMER TO REINFORCEMENT AND ATTACHMENT STEEL AND FRAMING WHICH WILL BE IN CONTACT WITH CONCRETE. D. CHEMICALLY TREAT SURFACES WITH PHOSPHATE COMPOUND TO ENSURE MAXIMUM PAINT ADHESION. APPLY A SUFFICIENT NUMBER OF COATS OF AN APPROVED ENAMEL FILLER, BAKED ON, TO OBTAIN UNIFORMLY SMOOTH EXPOSED SURFACE. IN ADDITION, APPLY ONE COAT OF LIGHT-COLORED PRIMER, BAKED ON, TO BOTH INSIDE AND OUTSIDE SURFACES. TOUCH UP SURFACES HAVING RUNS, SMEARS OR BARE SPOTS. E. PROVIDE MINIMUM MIL THICKNESSES OF COATING AS RECOMMENDED BY THE PAINT MANUFACTURER. PART 3 - EXECUTION 3.01 INSPECTION A. EXAMINE SUBSTRATE AND CONDITIONS UNDER WHICH STEEL DOORS AND FRAME WORK ARE TO BE INSTALLED FOR ANY CONDITIONS DETRIMENTAL TO PROPER AND TIMELY COMPLETION OF WORK. DO NOT PROCEED WITH WORK UNTIL UNSATISFACTORY CONDITIONS HAVE BEEN CORRECTED. 3.02 INSTALLATION A. INSTALL STEEL DOORS, FRAMES AND ACCESSORIES IN ACCORDANCE WITH FINAL SHOP DRAWINGS, MANUFACTURER'S DATA AND AS HEREIN SPECIFIED. B. FRAME INSTALLATION: SET FRAMES ACCURATELY IN POSITION, PLUMBED, ALIGNED AND BRACED SECURELY UNTIL PERMANENT ANCHORS ARE SET. AFTER WALL CONSTRUCTION IS COMPLETE, REMOVE TEMPORARY BRACES AND SPREADERS LEAVING SURFACES SMOOTH AND UNDAMAGED. C. DOOR INSTALLATION: FIT DOORS ACCURATELY IN THEIR RESPECTIVE FRAMES, WITH THE CLEARANCES SPECIFIED HEREIN. D. HARDWARE INSTALLATION: APPLY HARDWARE IN ACCORDANCE WITH HARDWARE MANUFACTURER'S INSTRUCTIONS AND "SECTION 08710 - FINISH HARDWARE " DRILL AND TAP FOR MACHINE SCREWS, AS REQUIRED. DO NOT USE SELF -TAPPING SHEET METAL SCREWS. ANCHOR PANELS IN PLACE WITH CONCEALED FASTENERS. ADJUST DOORS TO PROVIDE UNIFORM CLEARANCE AT HEAD AND JAMBS AND TO CONTACT STOPS UNIFORMLY. REMOVE AND REPLACE DOORS WHICH ARE WARPED, BOWED OR OTHERWISE DAMAGED AND CANNOT BE PROPERLY INSTALLED. 3.03 ADJUSTMENT AND CLEANING A. CHECK AND ADJUST FINISH HARDWARE ITEM FRAMES JUST PRIOR TO FINAL INSPECTION. LEAVE WORK IN PROPER OPERATING CONDITION. REPLACE DEFECTIVE WORK, INCLUDING DOORS AND/OR FRAMES WHICH ARE UNACCEPTABLE. B. IMMEDIATELY AFTER ERECTION, SAND SMOOTH ANY RUSTED OR DAMAGED AREAS OF PRIME COAT AND APPLY TOUCH-UP OF COMPATIBLE AIR -DRYING PRIMER. END OF SECTION 08100 SECTION 08370 - TEMPERED GLASS DOORS PART 1 - GENERAL 1.01 SUMMARY OF WORK A. THE WORK OF THIS SECTION INCLUDES, BUT IS NOT NECESSARILY LIMITED TO, THE FOLLOWING: TEMPERED GLASS DOORS AND SIDELIGHTS B. RELATED WORK SPECIFIED ELSEWHERE 1. FINISH HARDWARE - SEE SECTION 08710. 2. GLASS AND GLAZING - SEE SECTION 08800. 1.02 SUBMITTALS A. SHOP DRAWINGS 1. SHOW LOCATIONS, QUANTITIES, FABRICATION DETAILS AND INSTALLATION DETAILS, DIMENSIONS, FASTENINGS, HARDWARE, FINISHES, ETC., TO SHOW CONFORMANCE WITH THE REQUIREMENTS OF THE DRAWINGS AND SPECIFICATIONS. THESE SHOP DRAWINGS MUST BE REVIEWED BY THE DESIGNER BEFORE ANY FABRICATION OR INSTALLATION IS BEGUN. 2. COORDINATE SHOP DRAWINGS WITH SECTION 08710 TO ENSURE PROPER SIZE AND LOCATION OF CYLINDER LOCKS AND OTHER HARDWARE. B. PERFORMANCE GUARANTEES: FURNISH A TWO-YEAR GUARANTEE, CERTIFYING THAT WORK IS IN ACCORDANCE WITH THE CONTRACT DOCUMENTS INCLUDING AUTHORIZED ALTERATIONS AND ADDITIONS AN T D HA T SHOULD ANY DEFECTS IN MATERIALS AND WORKMANSHIP AFFECTING THE FUNCTION AND PERFORMANCE OF THE DOORS DEVELOP DURING THE GUARANTEE PERIOD, SUCH DEFECTS WILL, UPON WRITTEN NOTICE, BE REPAIRED OR REPLACED AT NO EXPENSE TO THE OWNER. GUARANTEE DOES NOT APPLY TO BREAKAGE OF GLASS. a `�1n1u11111""I .. .�`��,`,' .� CASS�,y,,���,0 O \STSRF �� No 1 0053 • F STATE .' ti. :; Q / V 1 O NoIAN y��.. & • . Slp I1/I II II�NN project no. 210780.03 drawn check by MC BP FULL SCALE (24X36): 1/8" = V-0" HALF-SIZE (12X18): 1/16" = V-0" (unless otherwise noted) sheet Ari S2 ARCHITECTURAL SPECIFICATIONS E Z O Z U 0 C U) N o to J J = J .J m a . U v 3 W >: U Z ACV of d M O co W 00 � CV M o/ LL F-- OcMu�OU � U j � � W � m ~ O ^ 0 (n co Z (o LU Z � � cf LLJ O Q p M W Lu J Lu 00 M } Lu � W J m � O J m- r- LJJ LLJ LuVUI-1 Q U project no. 210780.03 drawn check by MC BP FULL SCALE (24X36): 1/8" = V-0" HALF-SIZE (12X18): 1/16" = V-0" (unless otherwise noted) sheet Ari S2 ARCHITECTURAL SPECIFICATIONS ® (V M W U o W � Q of r � Z Q o/ LL F-- 4 W ^ Q I-Q0Z } J J - Q U m J W UM 2 T_ Q U project no. 210780.03 drawn check by MC BP FULL SCALE (24X36): 1/8" = V-0" HALF-SIZE (12X18): 1/16" = V-0" (unless otherwise noted) sheet Ari S2 ARCHITECTURAL SPECIFICATIONS