Loading...
HomeMy WebLinkAbout17C r 6/ A4.1 Partition T eS °' - WHEN SHORT WALL ENDS AT CORNER OF HIGH WALL, RETURN 2 DOOR ACTUATOR ON COLUMN - SEE DOOR HARDWARE SPECIFICATION FOR FURTHER INFORMATION. INSTALL @ A.D.A. REQUIRED HEIGHT. 3 DOOR ACTUATOR ON PEDESTAL - SEE DOOR HARDWARE SPECIFICATION FOR FURTHER INFORMATION. INSTALL @ A.D.A. REQUIRED HEIGHT. 4 i CAP AND TRIM AS SHOWN CASED OPENING, SIM. TO DOOR JAMB/HEAD, BUT WITHOUT STOPS FINISHED OPENING HEIGHT @ 7'-0" A.F.F. 6 I REFRIGERATOR. 7 ; NIGHT DEPOSIT BOX. 8 ATM, SEE DETAIL 2/A6.1. M REMOTE TRANSACTION SYSTEM Plan View 11 7 0" 9'- 0„ SAFE DEPOSIT BOX VAULT 13 ALL INTERIOR WALLS SHALL BE PARTITION TYPE 1.5 UNLESS NOTED OTHERWISE. 14 PROVIDE THREE 18" DEEP 3/4" THICK WHITE LAMINATE SHELVES. MOUNT @ 36" 50" AND 64" A.F.F. PROVIDE CONTINUOUS 2x2 PAINTED TO MATCH WALL AT BACK AND SIDES TO SUPPORT SHELVES. 15 CASED OPENING - FINISHED OPENING HEIGHT @ 8'-8" A.F.F., REFER TO DETAIL 13/A6.2. 16 LOW WALL SUPPORT COLUMN, SEE DETAIL 11/A6.2 OMIT GYP BD INSIDE OF MECHANICAL CHASES AND COLUMN ENCLOSURES U.N.O. 8 7/8" PROVIDE AND INSTALL KNOX BOX. VERIFY MOUNTING HEIGHT WITH FIRE DEPT. HAVING JURISDICTION. PAINT BOX PT -6 (SEE FINISH SCHEDULE 18 1 DOWNSPOUT - TIE INTO STORM DRAIN - SEE CIVIL DRAWINGS. o Q 2" 4 7/8" 2" 5/8" TYPE X GYP BD BOTH 5/8" TYPE X GYP BD BOTH TOP OF WALL SIDES TO UNDERSIDE SIDES TO UNDERSIDE c) OF DECK ABOVE OF DECK ABOVE 5'-2" AFF " - 5/4" OAK CAP - STAINED 5/8" TYPE X GYP BD BOTH 2 2 3 5/8" 20 GA MTL STUDS 3 5/8" 20 GA MTL STUDS SIDES TO 4" ABOVE HIGHEST @ 16" O.C. TO UNDERSIDE @ 16" O.C. TO UNDERSIDE 3/4" OAK COVE - STAINED ADJACENT CEILING A5.2 A3.1 OF DECK ABOVE OF DECK ABOVE 4 5/ A4.1 1X4 OAK TRIM WITH OGEE - STAINED 31/2" SOUND ATTENUATION A5.1 C, BATTS TO UNDERSIDE 5/8" TYPE X GYP BD 3 5/8" 20 GA MTL STUDS OF DECK ABOVE BOTH SIDES �7a 16"-O.0 T0UNDERStDE - - -I- --- -- - -�- - - _ - -� - - - L -3 5/8" 20 GA MTL OF DECK ABOVE N 1 STUDS @ 16" O.C. N 1.5 5/8" TYPE X GYP BD BOTH SIDES TO UNDERSIDE OF DECK ABOVE 6" 20 GA MTL STUDS @ 8" O.C. TO UNDERSIDE OF DECK ABOVE 1.5A 5/8" TYPE X GYP BD BOTH SIDES TO UNDERSIDE OF DECK ABOVE EXTERIC 6" 20 GA MTL STUDS @ 8" O.C. TO UNDERSIDE OF DECK ABOVE 6" SOUND ATTENUATION BATTS TO UNDERSIDE OF DECK ABOVE 1.5B 11.5C 1'-2" MASONRY AIR SPACE fERIOR 2" RIGID INSULATION j TYVEK COMMERCIAL WRAP 5/8" DENS-GLAS 6" MTL STUDS w/ 6" FSK 25 8'- 0" FOIL FACED BATTS - TAPE ALL EDGES AND OPENINGS 1'- 8" 6'- 4" V- 8" 5/8" TYPE X GYP BD I .1' - 1.7 1.7A 3.7 Specific Plan Notes 1 JAMB MOUNTED DOOR ACTUATOR - SEE DOOR HARDWARE SPECIFICATION FOR FURTHER INFORMATION. INSTALL @ A.D.A. REQUIRED HEIGHT. 2 DOOR ACTUATOR ON COLUMN - SEE DOOR HARDWARE SPECIFICATION FOR FURTHER INFORMATION. INSTALL @ A.D.A. REQUIRED HEIGHT. 3 DOOR ACTUATOR ON PEDESTAL - SEE DOOR HARDWARE SPECIFICATION FOR FURTHER INFORMATION. INSTALL @ A.D.A. REQUIRED HEIGHT. 4 COAT ROD AND SHELF, SEE DETAIL 15/A10.1. 5 CASED OPENING, SIM. TO DOOR JAMB/HEAD, BUT WITHOUT STOPS FINISHED OPENING HEIGHT @ 7'-0" A.F.F. 6 I REFRIGERATOR. 7 ; NIGHT DEPOSIT BOX. 8 ATM, SEE DETAIL 2/A6.1. 9 REMOTE TRANSACTION SYSTEM 10 PROVIDE AND INSTALL 4" CONCRETE FILLED GALVANIZED STEEL BOLLARDS WHERE SHOWN. PROVIDE FOUR BOLLARDS AT EACH REMOTE TRANSACTION SYSTEM LOCATION. COORDINATE INSTALLATION WITH BANK EQUIPMENT. PRIME BOLLARDS AND COVER WITH YELLOW BUMPER POST SLEEVES AS MANUFACTURED BY "IDEALSHIELD" (313-842-7290) OR APPROVED EQUAL. 11 CASH VAULT 12 SAFE DEPOSIT BOX VAULT 13 BULLETIN BOARD - 72" WIDE x 48" HIGH - MOUNT TOP @ 7'-4" A.F.F. 14 PROVIDE THREE 18" DEEP 3/4" THICK WHITE LAMINATE SHELVES. MOUNT @ 36" 50" AND 64" A.F.F. PROVIDE CONTINUOUS 2x2 PAINTED TO MATCH WALL AT BACK AND SIDES TO SUPPORT SHELVES. 15 CASED OPENING - FINISHED OPENING HEIGHT @ 8'-8" A.F.F., REFER TO DETAIL 13/A6.2. 16 LOW WALL SUPPORT COLUMN, SEE DETAIL 11/A6.2 17 PROVIDE AND INSTALL KNOX BOX. VERIFY MOUNTING HEIGHT WITH FIRE DEPT. HAVING JURISDICTION. PAINT BOX PT -6 (SEE FINISH SCHEDULE 18 1 DOWNSPOUT - TIE INTO STORM DRAIN - SEE CIVIL DRAWINGS. General Plan Notes THESE NOTES APPLY TO ALL CONSTRUCTION DOCUMENTS, AND TO ALL CONTRACTORS AND/OR SUB -CONTRACTORS THAT WORK WITHIN THIS BUILDING. 1. GENERAL CONTRACTOR SHALL BE RESPONSIBLE FOR ALL CONSTRUCTION REQUIRED FOR THE INSTALLATION OF NEW MATERIALS, WETHER OR NOT IT IS SPECIFICALLY SHOWN OR NOTED IN THESE DOCUMENTS. 2. THE GENERAL CONTRACTOR SHALL BE RESPONSIBLE FOR ALL NECESSARY BLOCKING FOR ALL TRADES. COORDINATE WITH ALL, INCLUDING BANK EQUIPMENT SUPPLIED BY OTHERS. 3. CONTRACTOR SHALL PROVIDE ALL NECESSARY PERMITS AND FEES REQUIRED TO COMPLETE THE PROJECT. 4. THE CONTRACTOR SHALL VERIFY ALL DIMENSIONS AND CONDITIONS RELATIVE TO THE PROJECT AS ILLUSTRATED. ANY CONFLICTS OR DISCREPANCIES SHALL BE REPORTED TO THE ARCHITECT IMMEDIATELY FOR RESOLUTION. 5. CONTRACTOR SHALL COORDINATE ALL WORK WITH EQUIPMENT MANUFACTURER TO ENSURE APPROPRIATE ROUGH -IN CLEARANCE FOR EQUIPMENT INSTALLATION AND USE. 6. WHERE MOUNTING HEIGHTS ARE NOT INDICATED, MOUNT INDIVIDUAL UNITS OF WORK AT RECOMMENDED STANDARD HANDICAP ACCESSIBILITY HEIGHTS FOR THE PARTICULAR WORK INDICATED. REFER QUESTIONABLE MOUNTIING HEIGHT TO THE ARCHITECT FOR A FINAL DECISION. 7. DO NOT SCALE DRAWING. 8. CONTRACTOR SHALL LAYOUT AND MARK ALL WALLS AND OPENINGS PRIOR TO CONSTRUCTION. ANY DISCREPANCY SHALL BE REPORTED TO THE ARCHITECT FOR IMMEDIATE RESOLUTION. 9. REFERENCE RELATED ELECTRICAL, MECHANICAL, AND PLUMBING DOCUMENTS FOR NEW CONSTRUCTION. 10. CONTRACTOR SHALL COORDINATE THE LOCATIONS AND SPECIFIC REQUIREMENTS FOR MECHANICAL, ELECTRICAL, AND PLUMBING ROUGH -INS. 11. ALL SUB -CONTRACTORS SHALL BE RESPONSIBLE FOR VISITING THE CONSTRUCTION SITE TO BECOME FAMILIAR WITH ALL EXISTING CONDITIONS WHICH AFFECT THAT SPECIFIC PORTION OF THEIR WORK. ANY CONFLICTS OR APPARENT DEFICIENCIES MUST BE SUBMITTED TO THE ARCHITECT IN WRITING PRIOR TO BIDDING. 12. SMOKING SHALL BE PROHIBITED IN THE BUILDING. 13. DEVELOP AND ENFORCE STORAGE, HOUSEKEEPING AND DEBRIS REMOVAL PROCEDURES THAT REDUCE THE FLAMMABLE AND COMBUSTIBLE FIRE LOAD TO THE LOWEST LEVEL NECESSAARY FOR DAILY OPERATIONS. 14. IOSHA REQUIRES MATERIAL SAFETY DATA SHEETS (MSDS) FOR ALL MATERIALS BEING USED OR STORED ON THIS PROJECT, BE MADE AVAILABLE TO ALL WORKERS ON THISJOB SITE. 15. SECURE ALL TOOLS AND CONSTRUCTION MATERIALS DURING BREAKS AND NON -CONSTRUCTION HOURS. 16. ALL CONSTRUCTION AREAS, REMOVAL TRAFFIC PATTERN AREAS AND ASSOCIATED WORK AREAS SHALL BE KEPT CLEAN OF DEBRIS BY THE CONTRACTORS DAILY. 17. GENERAL CONTRACTOR IS RESPONSIBLE FOR SEALING ALL BANK EQUIPMENT INSTALLEDIN WALLS OR CEILINGS. Floor Plan -o i MSKTD & Associates, Inc. ARCHITECTURE ENGINEERING INTERIOR DESIGN 1715 MAGNAVOX WAY 930 NORTH MERIDIAN FORT WAYNE, IN 46804 INDIANAPOLIS, IN 46204 voice 260.432.9337 voice 317.917.1190 fax 260.436.2402 fax 317.822.6236 http://www.msktd.com CERTIFICATION c� R K/ 0G\STERFo.T`�� • No. 19500182 ? STATE OF i •• • /ND I ANP • o- • The concepts, ideas, designs, plans, and details as shown on this document are the sole property of MSKTD & Associates, Inc., and were created, developed and presented for use on this specific project. None of the concepts, ideas, designs, plans, and details shall be used by any person, firm, or corporation for any purpose whatsoever, without the expressed written consent of MSKTD & Associates, Inc. The Owner shall be permitted to retain copies for information and reference in connection with this project. 810 I FRevisions: Date: By.- SHEET y: G SHEET TITLE I I Floor Plan COMMISSION NUMBER DATE MSKTD 5629 2-11-11 BUILD 65076 E NUMBER A2,01