Loading...
HomeMy WebLinkAbout43I I l i I I I I OUTDOOR GAS METER - G— 1 l j WORKROOM # 1 "0: HALLWAY CW S-2 130 3/4"o- 28 1"0 G HWR — 1 1/4"0 OFFIC 0 130 1" 119 UP TO ROOF MEN 3/4"0 W 1 1/2"0 3/4"n WOMEN � I If t OFFICE I 141 OFFICE 142 4 ::;:f ; -- — 5 OFFICE 143 J CW SUPPLY HALLWAY uvF - 11-1 F n 109 WC -1H. • U-11-1 L-1 H HALLWAY H. HWR 107 D-1 103 3/4"o WOMEN #'4l ..... 1 9 1 6 REC... .. EWC-1 .C1'—HWCW _ C HWw U 10 — uu! HUM -4 ,HUM -8 :" OFFICe 1 "0 4 3/4"0 OFFICE144 3/4"0 , , „A 3/4"o 1 1/4"o O O `E O O Plumbing First Floor Domestic Water, Gas and Sprinkler Plan QL) 1/8" = 1'-0" �13 cY) N N LO N r 0 N r N P2.1 CONSTRUCTION NOTES 1 HUMIDIFIER LOCATIONS AS SHOWN AND PER SECTION ON SHEET P5.1. REFER TO DETAIL ON SHEET P5.1 FOR INSTRUCTIONS, ELEVATIONS, ETC. STEAM PIPING NOT SHOWN. USE AS FEW 90° ELBOWS AS POSSIBLE. 2 FURNISH AND INSTALL TRAP PRIMER DISTRIBUTION UNIT TO SERVE THESE TWO FLOOR DRAINS IN ROOM 109. 3 PROVIDE REGULATOR TO GAS LINE SERVING WATER HEATER. VENT REGULATOR THROUGH ROOF. 4 FURNISH INLINE TRAP PRIMER TO SERVE ADJACENT FLOOR DRAIN. 5 PAINT EXPOSED PORTIONS OF GAS PIPE TO MATCH EXTERIOR OF BUILDING. 6 EXTEND 1/2" CW LINE WITH BALL VALVE, STRAINER TO EACH HUMIDIFIER. FOLLOW MANUFACTURER'S RECOMMENDATIONS. 7 SPRINKLER MAIN TO SERVE BUILDING. PROVIDE A FULLY WET SYSTEM PER NFPA 13 REQUIREMENTS. CONTRACTOR TO DEVELOP DRAWINGS AND SUBMIT TO STATE. 8 FURNISH AND INSTALL HOT WATER RETURN BALANCE VALVE. SET TO 0.5 GPM. 9 TOILET FLUSH HANDLES SHALL BE OPPOSITE THE CLOSEST STALL WALL. 10 SPRINKLER LINE FOR LOBBY 101 SHALL ENTER ROOM TIGHT TO UNDERSIDE OF BEAM AND SHALL RISE BETWEEN COLUMN AND WINDOW MULLION. PAINT TO MATCH STEEL COLUMN. 11 SPRINKLER LINE FOR VESTIBULE 100 SHALL DROP BETWEEN COLUMN AND WINDOW MULLION. PAINT TO MATCH STEEL COLUMN. MSKTD & Associate Inc. c. ARCHITECTURE ENGINEERING INTERIOR DESIGN 1715 MAGNAVOX WAY 930 NORTH MERIDIAN FORT WAYNE, IN 46804 INDIANAPOLIS, IN 46204 voice 260.432.9337 voice 317.917.1190 fax 260.436.2402 fax 317.822.6236 http://www.msktd.com CERTIFICATION \\\�'0AW111I I111D.� •.G\STERE •.•��`��ii �•: No. * ; 890360% ; i '; STATE OF �A*\ %. BIND I ANP••.•.•�� 111S*00-00 SIONAL 1\\ The concepts, ideas, designs, plans, and details as shown on this document are the sole property of MSKTD & Associates, Inc., and were created, developed and presented for use on this specific project. None of the concepts, ideas, designs, plans, and details shall be used by any person, firm, or corporation for any purpose whatsoever, without the expressed written consent of MSKTD & Associates, Inc. The Owner shall be permitted to retain copies for information and reference in connection with this project. FRevisions: Date: By: SHEET TITLE Plumbing Domestic Water, Gas and Fire Floor Plan E SSION NUMBER DATE KTD 5629 2-11-11 LD 65076 SHEET NUMBER P201