Loading...
HomeMy WebLinkAbout45I A O N N COLD WATER FEED TO OTHER FIXTURES TRAP PRIMER VALVE UNIT, PPP-PR500 OR SIMILAR TRAP PRIMER DISTRIBUTION UNIT, PPP DU -U OR SIMILAR UJ a a 00 2i :z Z:) =) Z J FLOOR DRAIN a N O N 0 Q a d • a P -TRAP Automatic Trap Primer Detail 1 1/2" BYPASS PEAK GPM = 40 AVG. GPM = 20 TYP. BALL VALVE TEST COCK TYP., 1/4 TURN BALL VALVE TYP. STRAINER 11s 2" CW TO BUILDING SERVICE TYP. FLANGED CONNECTION — 2" INCOMING DOMESTIC WATER METER BY SERVICE LOCAL UTILITY, PAID FOR UNDER THIS CONTRACT 1" 03 03 SUB -METER FOR IRRIGATION ROUTE UNDERGROUNDRPZ FOR IRRIGATION TO S OUTSIDE BUILDING FOR Z REDUCED PRESSURE BACKFLOW IRRIGATION TO FLOOR DRAIN N PREVENTER ASSEMBLIES TO BE LOCATED BOTTOM MIN. 12" A.F.F., SIZE PER AIR GAP TOP MAX 60" A.F.F. Water Meter Backflow Preventer Detail CLAMP FLANGE GAS SIZE SIZE SIZE 3" 1/2" 2" - 2 1/2" 2" 1/4" 1 1/2" 1 1/2" 1/4" 1"- 1 1/4" 1" 1/4" 1/2" - 3/4" — FLOW SPLIT PIPE CLAMP GRININEL 3138 OR EQUAL BLACK IRON GAS PIPE INSTALL PIPE LEVEL — PIPE NIPPLE COORDINATE HEIGHTS 12x12 20 GAUGE GALV. PLATE ON ROOFING. NO GRAVEL UNDER PLATE Natural Gas PiDe Suppoft Not to Scale CIAIIQUEM CI nnn ADJUSTING COLLAR RISER 1/8 BEND FULL SIZE, 4" MAX. -------------- - PLUG IF END OF LINE Floor Cleanout Detail 1. FURNISH WITH COND EN SATE/B LOW DOWN COOLER OPTION. 2. FURNISH WITH SHORT ABSORPTION MANIFOLD (SAM) FOR DISPERSION AT DUCTWORK (SIZED PER EACH DUCT, SEE SHEET M2.1). THERMOMETER —110° F—� ELECTRIC WATER HEATER MOUNT APPROX. 6'- 0" A. F. F, SUPPORT AS REQUIRED FOR FULL OPERATING WEIGHT PRESSURE & TEMPERATURE ASME RELIEF VALVE KUNKLE MODEL 912 LINE SIZE T & P RELIEF VALVE DRAIN VALVE 110° F �—T CW — CHECK VALVE AQUASTAT IHWR -7 � — � - BALL VALVE STRAINER HOT WATER RECIRC. PUMP ON @ 100 OFF @ 110 FLOOR DRAIN Electric Water Heater w/ Recirc. Detail STATE APPROVED REDUCED PRESSURE BACKFLOW PREVENTER ASSEMBLY AIR GAP FUNNEL PROVIDED BY RPBP CD MFG. AS REQUIRED TO FLOOR DRAIN SIZE PER AIR GAP 115V ELECT"" ALARM BE CHECK VAL' FIRE DEPARTI CONNECTION BALL DRIP 115V TAMPER �- PIPE PATE STEPPED POLYVINYL PATE STAINLESS CHLORIDE BOOT ADJUSTABLE CLAMPS PATE SPUN INSULATION ALUMINUM BASE ROOF DECK ROOF MEMBRANE Pate Pi-ve Seal Detail Not to Scale 15V WATER FLOW NDICATOR -EE CONNECTION VATER GAUGE EE CONNECTION 1AIN DRAIN VALVE 1AIN DRAIN =LOW TEST LINE) OUBLE CHECK VALVE SSEMBLY(APPROVED OR WILKINS BRAND NLY) ISER FROM MAIN WATER UPPLY (6"0 LEAD-IN) Wet Pi -De Vertical Sprinkler Riser Not to Scale Plumbing Fixture Schedule: CO -1 CLEANOUT - FLOOR ZURN Z -1400 -NL "LEVEL-TROL" ADJUSTABLE FLOOR CLEANOUT. DURA -COATED CAST S_1 SINK - SINGLE COMPARTMENT A. ELKAY #LRAD2219, BOWL: 18"04N6" DEEP, 18 GA. STAINLESS STEEL SELF -RIMMING IRON. SIZE PER LOCAL PLUMBING CODE. (JOSAM 58360 IS APPROVED EQUAL.) HUMIDIFIER SCHEDULE CO -2 CLEANOUT WALL B. ELKAY #LKLFD2439 DUAL HANDLE LOW -FLOW KITCHEN FAUCET, 3-4" CENTERS, WRISTBLADE ZURN Z-1441 WALL CLEANOUT WITH ROUND STAINLESS STEEL ACCESS COVER. SIZE HANDLES, 1.5 GPM AERATOR. C. #LK -35 BASKET STRAINER WITH NEOPRENE STOPPER AND TAILPIECE. PER LOCAL PLUMBING CODE. (JOSAM 58910 W/ 58600 IS APPROVED EQUAL.) D. P -TRAP, CHROME -PLATED CAST BODY WITH CLEANOUT, ESCHUCHEON. CO -3 CLEANOUT OVERHEAD E. SOLID BRASS ANGLES STOPS, CHROME PLATED, LOOSE KEY, CHROME -PLATED RISERS AND STEAM CAP ADJ.RANGE EXTENSION TUBES. F. FURNISH TEMPLATE TO COUNTER TOP SUPPLIER. BREAKER --- MARK MANUFACTURER MODEUSIZE SERVED (LBS HR) MIN ELECTRICAL SIZE NOTES HUM -1 Nortec NHTC-010TU-1 tR 10 20% 208/1/60 25 1,2 HUM -2 Nortec NHTC-010TU-2 C. FIAT #832AA HOSE AND HOSE BRACKET. D. FIAT #833AA SILICON SEALANT. 10 20% 208/1/60 25 1,2 HUM -3 Nortec NHTC-010TU-3 --- 10 20% 208/1/60 25 _1 2 HUM -4 Nortec NHTC-020 RTU -4 20 20% 208/3!60 30 1,2 HUM -5 Nortec NHTC-010 RTU -5 10 20% 208/1/60 25 1,2 HUM 6 Nortec NHTC-010 RTU -6 10 20% 208!1/60 25 1,2 HUM -7 Nortec NHTC-010 RTU -7 10 20% 208/1/60 25 1,2 HUM -8 Nortec NHTC-020 RTU -8 20 20% 208/3/60 30 1,2 1. FURNISH WITH COND EN SATE/B LOW DOWN COOLER OPTION. 2. FURNISH WITH SHORT ABSORPTION MANIFOLD (SAM) FOR DISPERSION AT DUCTWORK (SIZED PER EACH DUCT, SEE SHEET M2.1). THERMOMETER —110° F—� ELECTRIC WATER HEATER MOUNT APPROX. 6'- 0" A. F. F, SUPPORT AS REQUIRED FOR FULL OPERATING WEIGHT PRESSURE & TEMPERATURE ASME RELIEF VALVE KUNKLE MODEL 912 LINE SIZE T & P RELIEF VALVE DRAIN VALVE 110° F �—T CW — CHECK VALVE AQUASTAT IHWR -7 � — � - BALL VALVE STRAINER HOT WATER RECIRC. PUMP ON @ 100 OFF @ 110 FLOOR DRAIN Electric Water Heater w/ Recirc. Detail STATE APPROVED REDUCED PRESSURE BACKFLOW PREVENTER ASSEMBLY AIR GAP FUNNEL PROVIDED BY RPBP CD MFG. AS REQUIRED TO FLOOR DRAIN SIZE PER AIR GAP 115V ELECT"" ALARM BE CHECK VAL' FIRE DEPARTI CONNECTION BALL DRIP 115V TAMPER �- PIPE PATE STEPPED POLYVINYL PATE STAINLESS CHLORIDE BOOT ADJUSTABLE CLAMPS PATE SPUN INSULATION ALUMINUM BASE ROOF DECK ROOF MEMBRANE Pate Pi-ve Seal Detail Not to Scale 15V WATER FLOW NDICATOR -EE CONNECTION VATER GAUGE EE CONNECTION 1AIN DRAIN VALVE 1AIN DRAIN =LOW TEST LINE) OUBLE CHECK VALVE SSEMBLY(APPROVED OR WILKINS BRAND NLY) ISER FROM MAIN WATER UPPLY (6"0 LEAD-IN) Wet Pi -De Vertical Sprinkler Riser Not to Scale Plumbing Fixture Schedule: CO -1 CLEANOUT - FLOOR ZURN Z -1400 -NL "LEVEL-TROL" ADJUSTABLE FLOOR CLEANOUT. DURA -COATED CAST S_1 SINK - SINGLE COMPARTMENT A. ELKAY #LRAD2219, BOWL: 18"04N6" DEEP, 18 GA. STAINLESS STEEL SELF -RIMMING IRON. SIZE PER LOCAL PLUMBING CODE. (JOSAM 58360 IS APPROVED EQUAL.) SINGLE COMPARTMENT SINK WITH 3 FAUCET HOLES @ 4" CENTERS. CO -2 CLEANOUT WALL B. ELKAY #LKLFD2439 DUAL HANDLE LOW -FLOW KITCHEN FAUCET, 3-4" CENTERS, WRISTBLADE ZURN Z-1441 WALL CLEANOUT WITH ROUND STAINLESS STEEL ACCESS COVER. SIZE HANDLES, 1.5 GPM AERATOR. C. #LK -35 BASKET STRAINER WITH NEOPRENE STOPPER AND TAILPIECE. PER LOCAL PLUMBING CODE. (JOSAM 58910 W/ 58600 IS APPROVED EQUAL.) D. P -TRAP, CHROME -PLATED CAST BODY WITH CLEANOUT, ESCHUCHEON. CO -3 CLEANOUT OVERHEAD E. SOLID BRASS ANGLES STOPS, CHROME PLATED, LOOSE KEY, CHROME -PLATED RISERS AND JOSAM 58900 SERIES COATED CAST IRON CLEANOUT FERRULE, NO -HUB CONNECTION, BRONZE EXTENSION TUBES. F. FURNISH TEMPLATE TO COUNTER TOP SUPPLIER. COUNTERSUNK PLUG. SIZE PER LOCAL PLUMBING CODE. --- FD -1 FLOOR DRAIN - ROUND WITH CLEANOUT - 6", 2" CONNECTION JOSAM #30500-A SERIES CAST IRON COMBINATION FLOOR DRAIN AND INTEGRAL DEEP DRUM S_2 SINK - SINGLE COMPARTMENT A. ELKAY #LRAD1918, BOWLS: 16"x11 -1/2"x6" DEEP, 18 GA. STAINLESS STEEL SELF -RIMMING "P" TRAP WITH DOUBLE DRAINAGE FLANGE, WEEP HOLES, SIDE OUTLET SPIGOT CONNECTION, SINGLE COMPARTMENT SINK WITH 3 FAUCET HOLES @ 4" CENTERS. B. ELKAY #LKD2438BH DUAL HANDLE LOW -FLOW KITCHEN FAUCET, 34" CENTERS, WRISTBLADE NIKALOY INTEGRAL FLUSH -WITH -FLOOR CLEANOUT AND ADJUSTABLE SATIN NIKALOY 6" ROUND HANDLES, 1.0 GPM AERATOR. STRAINER. C. #LK -35 BASKET STRAINER WITH NEOPRENE STOPPER AND TAILPIECE. FD -2 FLOOR DRAIN - ROUND WITH CLEANOUT - 8", 3" CONNECTION D. P -TRAP, CHROME -PLATED CAST BODY WITH CLEANOUT, ESCHUCHEON. E. SOLID BRASS ANGLES STOPS, CHROME PLATED, LOOSE KEY, CHROME -PLATED RISERS AND JOSAM #30500-A SERIES CAST IRON COMBINATION FLOOR DRAIN AND INTEGRAL DEEP DRUM "P" EXTENSION TUBES. TRAP WITH DOUBLE DRAINAGE FLANGE, WEEP HOLES, SIDE OUTLET SPIGOT CONNECTION, F. FURNISH TEMPLATE TO COUNTER TOP SUPPLIER. NIKALOY INTEGRAL FLUSH -WITH -FLOOR CLEANOUT AND ADJUSTABLE SATIN NIKALOY 8" ROUND STRAINER. MB -1 MOP BASIN - SHEET MOLDING COMPOUND ALL FLOOR DRAINS SHALL HAVE DEEP SEAL TRAPS. A. FIAT #MSB -2424 24"x24", 10" HIGH WALLS. B. FIAT #830AA FAUCET SET. WHERE ANY TYPE FLOOR DRAIN IS NOT SPECIFIED FOR A GIVEN LOCATION, IT SHALL BE THE SAME C. FIAT #832AA HOSE AND HOSE BRACKET. D. FIAT #833AA SILICON SEALANT. AS USED ELSEWHERE IN SIMILAR LOCATIONS AND/OR SIMILAR USAGE. E. INCLUDE 2" P -TRAP. RD -1 ROOF DRAIN F. FIAT#889-CC MOP BRACKET 24"x3" WIDE STAINLESS STEEL WITH THREE RUBBER GRIPS. ZURN #ZC100 15" DIAMETER DURA -COATED CAST IRON BODY, COMBINATION MEMBRANE RCP -1 RECIRCULATION PUMP -DOMESTIC HOT WATER FLASHING CLAMP/GRAVEL GUARD AND LOW SIHOUETTE CAST IRON DOME. (JOSAM #21500 -AE SERIES IS AN APPROVED EQUAL.) A. GRUNDFOS MAGNA 25-60N, 1/12 HP; 115/1/60 --- B. 1 GPM, 20 FT. HEAD ORD -1 OVERFLOW ROOF DRAIN C. CAST BRONZE PUMP BODYD. STAINLESS STEEL FACE PLATE ZURN #ZC100-W2 15" DIAMETER DURA -COATED CAST IRON BODY, COMBINATION MEMBRANE E. 30% GLASS FILLED NORYL IMPELLOR FLASHING CLAMP/GRAVEL GUARD, LOW SIHOUETTE CAST IRON DOME, 2" INTERNAL WATER F. SOLID HIGH-STRENGTH ALLOY STEEL SHAFT DAM. (JOSAM #21500 -AE -16 SERIES IS AN APPROVED EQUAL.) G CARBON/SILICON CARBIDE SEAL SYSTEM L -1H LAVATORY -WALL MOUNTED, ADA H. PERMANENTLY LUBRICTED SEALED BEARINGS I. AQUASTAT A. AMERICAN STANDARD #0495.300 "OVALYN" VITREOUS CHINA, UNDERCOUNTER LAVATORY WITH 4" FAUCET CENTERS, 17"x14"x5-1/2" DEEP, ROUND, WHITE. B. ZURN Z6915 -GEN "AQUASENSE" LAVATORY FAUCET WITH HYDROELECTRIC GENERATOR. BFP-1 REDUCED PRESSURE PRINCIPLE BACKFLOW PREVENTER C. 1 1/4" POLISHED CHROME, CAST BRASS, ADJUSTABLE "P" TRAP, CLEANOUT PLUG, TAPPED A. WILKINS MODEL #975XL; 2" B. CAST BRONZE (ASTM B854) MAIN VALVE BODY AND ACCESS COVER OUTLET FOR I.P. D. 3/8" I.P.S. ANGLE SUPPLIES WITH LOOSE KEY STOPS AND ANNEALED VERTICAL TUBES. C. STAINLESS STEEL (300 SERIES) SPRINGS AND FASTENERS D. SILICONE SEAT DISC; NSF LISTED NORYL SEAT RING AND INTERNAL POLYMERS E. LAVATORY TO BE MOUNTED AT 34" TO RIM (COUNTERTOP). F. OFFSET DRAIN ASSEMBLY FOR WHEELCHAIRS. E. THE FIRST AND SECOND CHECKS SHALL BE ACCESSIBLE FOR MAINENTANCE WITHOUT G. TRUEBRO MODEL #103 HANDI LAV -GUARD INSULATION KIT. REMOVING THE RELIEF VALVE OR THE ENTIRE DEVICE FROM THE LINE F. INCLUDE AIR GAP WC -1 WATER CLOSET - WALL HUNG, FLUSH VALVE A. AMERICAN STANDARD "AFWALL" FLOWISE EL ADA1.1/1.6 GPF HIGH EFFICIENCY TOILET SYSTEM, ET -1 EXPANSION TANK - POTABLE HOT WATER "THERM-X-TROL" ELONGATED BOWL, WALL MOUNTED AT 15" TO RIM, 1 1/2" TOP SPUD, 2-1/8" FULLY GLAZED AMTROL ASME MODEL # ST -5-C, 2.1 GAL TOTAL VOLUME, 0.9 GAL MAX MAXIMUM ACCEPTANCE, 3/4" NPT CONNECTION TRAPWAY WITH SIPHON JET ACTION. SHOCK ABSORBER B. ZURN MODEL #P6000 -M ADA DF HIGH EFFICIENCY DUAL -FLUSH FLUSHOMETER VALVE. EWH-1 WATER HEATER C. JOSAM SERIES #12674 -HS, 12684 -HS, 12694 -HS CAST IRON CLOSET CARRIER - ADJUSTABLE CLOSET CONNECTION, ADJUSTABLE FEET, CHROME PLATED TRIM AND COATED ACCESSORIES A. A.O.SMITH MODEL ECL -30 PROMAX LOWBOY FOR USE WITH TOILET SPECIFIED WITH TEST CAP. (J.R. SMITH IS APPROVED EQUAL) B. HEATER STORAGE: 30 GAL C. INPUT: 4500 W AT 240 V, ENERGY FACTOR 0.93 D. ELONGATED OPEN FRONT SEAT WITH STAINLESS STEEL CHECK HINGE. (OLSONITE AND CHURCH ARE APPROVED.) D. HEATER RECOVERY: 21 GPH @ 90 DEGREE RISE WC -1H WATER CLOSET - WALL HUNG, FLUSH VALVE, ADA DSP -1 KITCHEN SINK DISPOSAL A. INSINKERATOR "BADGER 5" SINK DISPOSAL A. AMERICAN STANDARD "AFWALL" FLOWISE EL ADA1.1/1.6 GPF HIGH EFFICIENCY TOILET SYSTEM, B. 1/2 HP, 120V/1/60, 1725 RPM, 6.9 AVERAGE AMP. ELONGATED BOWL, WALL MOUNTED AT 17" TO RIM, 1 1/2" TOP SPUD, 2-1/8" FULLY GLAZED U- TRAPWAY WITH SIPHON JET ACTION. B. ZURN MODEL #P6000 -M -ADA -DF HIGH EFFICIENCY DUAL -FLUSH FLUSHOMETER VALVE. JOSAM SERIES #12674 -HS, 12684 12694 General PlumbimyNotes:C. -HS, -HS CAST IRON CLOSET CARRIER - ADJUSTABLE VTR VENT THROUGH ROOFS CLOSET CONNECTION, ADJUSTABLE FEET, CHROME PLATED TRIM AND COATED ACCESSORIES END FOR USE WITH TOILET SPECIFIED WITH TEST CAP. (J.R. SMITH IS APPROVED EQUAL) 1. ALL WORK SHALL CONFORM TO STATE AND LOCAL PLUMBING AND BACKFLOW PREVENTION D. ELONGATED OPEN FRONT SEAT WITH STAINLESS STEEL CHECK HINGE. (OLSONITE AND CODES, AND THE REQUIREMENTS OF THE LOCAL WATER UTILITY. CHURCH ARE APPROVED.) --*— 2. VACUUM BREAKERS MUST BE INSTALLED ON ALL PROPOSED HOSE THREAD FITTINGS, U -1H URINALS - AUTO FLUSH, ADA COMPLIANT INCLUDING BUT NOT LIMITED TO HOSE BIBBS, WALL/YARD HYDRANTS, MOP/SERVICE SINKS. A. ZURN MODEL #Z5738.205.00 "THE SMALL PINT" 1/8 GPF ECO -VANTAGE ULTRA LOW CONSUMPTION BATTERY POWERED URINAL SYSTEM. 3/4" TOP SPUD WITH MANUAL OVERRIDE BUTTON. 3. A CROSS -CONNECTION CONTROL DEVICES INSPECTOR SHALL TEST ALL BACKFLOW DEVICES B. JOSAM URINAL CARRIER #17560 -UR, COMPLETE WITH BLOCK FEET AND POSITIONING FRAME. AT THE TIME OF INSTALLATION AND SUBMIT REPORTS TO THE LOCAL WATER UTILITY AS (OR ZURN #Z-1222, AND J.R. SMITH ARE APPROVED EQUALS.) RETROFIT BRACKET AS REQUIRED. REQUIRED. C. MOUNT AT 17" TO RIM. WASTE/STORM PIPING (UNDERGROUND) 4. COORDINATE EXACT LOCATION OF ROOF DRAINS WITH ARCHITECTURAL AND STRUCTURAL SC -1 SILCOCK - FREEZING AREAS PLANS. A. B&K INDUSTRIES MODEL #104-559HC FROST -FREE SILCOCK —SAN— B. 3/4" HOSE OUTLET 5. ALL MATERIALS INSTALLED WITH PLENUM SHALL HAVE FLAME SPREAD RATING OF NOT MORE C. CHROME -PLATED LEAD-FREE SILVER SOLDER CONSTRUCTION THAN 25 AND A SMOKE DEVELOPED RATING NOT EXCEEDING 50 IN ACCORDANCE WITH STATE CODES. EWC-1 H ELECTRIC WATER COOLER - SPLIT-LEVEL A. HALSEY TAYLOR #HTHB-HAC8BL "HAC", 3.7 AMPS, 325 W, 115/60/1, WALL MOUNTED, 8 GPH 6. THIS CONTRACTOR SHALL PROVIDE ALL EQUIPMENT, MATERIALS AND LABOR FOR CORE @ 50-F. INCLUDES "HYDROBOOST" BOTTLE FILLING STATION MOUNTED ON TOP. DRILLING AS REQUIRED FOR INSTALLATION OF PIPING PENETRATING BUILDING CONSTRUCTION. B. STAINLESS STEEL FINISH. C. MOUNT AT 34.5" TO LOWER BUBBLER OUTLET. 7. ALL EQUIPMENT USING NATURAL GAS SHALL HAVE A GAS COCK AND DIRT LEG FOR EACH D. ZURN Z-1225 PLATE TYPE SYSTEM WATER COOLER SUPPORT WITH DURA -COATED STEEL PIECE OF EQUIPMENT. UPRIGHTS, ADJUSTABLE SUPPORT PLATES AND MOUNTING. (JOSAM 17560-WCBL EQUAL) 8. REFERENCE ARCHITECTURAL DRAWINGS FOR ALL DIMENSIONS, TYPICAL. Fire ProtectionSDecification 9• ALL NATURAL GAS PIPING SERVING RTU'S ARE LOCATED ON ROOF. SEE SHEET M2.2. THIS CONTRACTOR SHALL INSTALL SPRINKLER SYSTEM THROUGHOUT THE ENTIRE NEW BUILDING 10. CONNECT PLUMBING FIXTURES TO PIPING INDICATED PER THE PLUMBING FIXTURE/EQUIPMENT PER NFPA 13. FIRE PROTECTION CONTRACTOR SHALL DEVELOP DRAWINGS WITH LISTED CONNECTION SCHEDULE AND/OR AS NOTED. REFER TO PIPING ISOMETRICS FOR ADDITIONAL EQUIPMENT AS REQUIRED, AND SUBMIT DRAWINGS TO THE STATE FOR APPROVAL. THIS PIPING REQUIREMENTS. CONTRACTOR MUST BE REGULARLY ENGAGED IN FIRE PROTECTION INSTALLATION. 11. COORDINATE MECHANICAL PENETRATIONS OF/WITH OTHER WORK TO AVOID INTERFERENCES, SPRINKLER HEADS SHALL BE UPRIGHT, OR PENDANT WITH RECESSED ESCUTCHEON AS SEAL PENETRATIONS AS NOTED AND/OR SPECIFIED. MANUFACTURED BY GRINNEL, VIKING, FIKE, OR AUTOMATIC. RECESSED HEADS SHALL BE OF THE BEST QUALITY CHROME PLATED, AND SHALL BE CENTERED IN CEILING TILE. 12. PIPING INVERTS AND/OR ELEVATIONS INDICATED ARE PRELIMINARY IN NATURE AND ARE FOR COORDINATION ONLY. THE CONTRACTOR IS RESPONSIBLE FOR FIELD VERIFYING AND IN DRYWALL CEILINGS USE CONCEALED HEADS, HORIZON MIRAGE BY VIKING OR APPROVED EQUAL. ESTABLISHING FINAL INVERTS AND/OR ELEVATIONS. INDICATE FINAL INSERTS AND/OR ELEVATIONS ON RECORD DOCUMENTS. IN ALL OTHER AREAS USE SEMI -RECESSED HEAD, MODEL M BY VIKING OR APPROVED EQUAL. 13. REFER TO ARCHITECTURAL PLANS FOR WALL TYPES IN WHICH PLUMBING IS TO BE INSTALLED. SYSTEM SHALL COMPLY WITH ALL LOCAL, STATE AND NFPA CODES AND OWNER INSURANCE COORDINATE PLUMBING INSTALLATION WITH OTHER WORK. AGENCY. ALL AREAS SHALL BE DESIGNED FOR LIGHT HAZARD. Pl b' � iuiiivu491-A19111CC1111V, 13YI110015 **-*H PLUMBING ROUGH -INS --------- VENT PIPING FIXTURE WASTE VENT HOT COLD WC-* 4" 2" --- ill U-* 2" 1 1/2" --- 3/4" L-* 1 1/2" 1 1/2" 1/2" 1/2" S-* 1 1/2" 2 MOP SINK 1/2" EWC-* 1 1/2" 1 1/2" MB-* 3"/2" TEE 1 /2" HB-* --- --- --- 3/4" FD-* 3" - - --- --- SH-* 2"3/4" RISER UP (TEE) H = (1" FOR EACH V OF MAXIMUM � iuiiivu491-A19111CC1111V, 13YI110015 **-*H FOLLOW ADA GUIDELINES --------- VENT PIPING CO- CLEAN OUT —G— GAS PIPING DF- DRINKING FOUNTAIN COLD WATER EWC- ELECTRIC WATER COOLER -- HOT WATER EWH ELECTRIC WATER HEATER ----- RECIRCULATING HOT WATER FD- FLOOR DRAIN —SOFT— SOFTENED WATER GWH- GAS WATER HEATER — DE— DEIONIZED WATER a e raU etal MSKTD & Associates, Inc. ARCHITECTURE ENGINEERING INTERIOR DESIGN 1715 MAGNAVOX WAY 930 NORTH MERIDIAN FORT WAYNE, IN 46804 INDIANAPOLIS, IN 46204 voice 260.432.9337 voice 317.917.1190 fax 260.436.2402 fax 317.822.6236 http://www. m sktd.com CERTIFICATION PSL D. * 890360 -)3 STATE OF : ,Qj 0 0. 5k\, %. %VD I AN .0 �� The concepts, ideas, designs, plans, and details as shown on this document are the sole property of MSKTD & Associates, Inc., and were created, developed and presented for use on this specific project. None of the concepts, ideas, designs, plans, and details shall be used by any person, firm, or corporation for any purpose whatsoever, without the expressed written consent of MSKTD & Associates, Inc. The Owner shall be permitted to retain copies for information and reference in connection with this project. Revisions: Date: By: FSHEETE bing Schedules and Details COMMISSION NUMBER DATE MSKTD 5629 2-11-11 BUILD 65076 SHEET NUMBER I P 5,0 HB- HOSE BIB —0— OXYGEN 0---+ HOSE BIB UNDERGROUND UTILITY SERVICE L- LAVATORY MB- MOP BASIN METER MS- MOP SINK 4 THERMOMETER MV- MIXING VALVE TEE DRAIN PAN = P- PUMP a ---RISER UP (ELBOW) J PRV- PRESSURE REDUCING VALVE RISER UP (TEE) H = (1" FOR EACH V OF MAXIMUM PV- AUTOMATIC PLUMBING VENT O— RISER DOWN (ELBOW) NEGATIVE STATIC PRESSURE) + 1" � DRAIN J - H/2 SD- S_ SINK —� RISER DOWN (TEE) SA SHOCK ABSORBER Is BALL VALVE L = H + J + PIPE DIAMETER + INSULATION SH- SHOWER —40— BUTTERFLY VALVE T- THERMOMETER — GAS COCK NOTES: U- URINAL T GATE VALVE 1. AHU COMPONENT PRESSURE DROPS ARE BASED UPON THE SCHEDULED VTR VENT THROUGH ROOFS DOUBLE BACK FLOW PREVENTER EQUIPMENT. CONTRACTOR TO INCREASE TRAP DEPTH (AND HOUSEKEEPING PAD WC- WATER CLOSET F— CHECK VALVE HEIGHT) AS NECESSARY PER INSTALLED EQUIPMENT. --*— UNION 2. FILTER PRESSURE DROP BASED UPON DIRTY FILTERS — ST— STORM WATER 3. APPLIES TO DRAW -THROUGH AIR HANDLING UNITS ONLY ON INDICATES DIRECTION OF FLOW PRESSURE GAUGE WASTE/STORM PIPING (UNDERGROUND) e CONNECT NEW TO EXISTING Condens t T D • 1 —SAN— WASTE PIPING NOTE: SOME SYMBOLS MAY NOT BE USED a e raU etal MSKTD & Associates, Inc. ARCHITECTURE ENGINEERING INTERIOR DESIGN 1715 MAGNAVOX WAY 930 NORTH MERIDIAN FORT WAYNE, IN 46804 INDIANAPOLIS, IN 46204 voice 260.432.9337 voice 317.917.1190 fax 260.436.2402 fax 317.822.6236 http://www. m sktd.com CERTIFICATION PSL D. * 890360 -)3 STATE OF : ,Qj 0 0. 5k\, %. %VD I AN .0 �� The concepts, ideas, designs, plans, and details as shown on this document are the sole property of MSKTD & Associates, Inc., and were created, developed and presented for use on this specific project. None of the concepts, ideas, designs, plans, and details shall be used by any person, firm, or corporation for any purpose whatsoever, without the expressed written consent of MSKTD & Associates, Inc. The Owner shall be permitted to retain copies for information and reference in connection with this project. Revisions: Date: By: FSHEETE bing Schedules and Details COMMISSION NUMBER DATE MSKTD 5629 2-11-11 BUILD 65076 SHEET NUMBER I P 5,0