Loading...
HomeMy WebLinkAbout49TIE TO EM -1 66 770 N CY) C\J i K06 — �— - - - I - -- - - 1 NH i A B E F G H I � K6L (P 1/8"=11_011 First Floor Liahting Plan __0 10 MSKTD & Associates, Inc. ARCHITECTURE ENGINEERING INTERIOR DESIGN 1715 MAGNAVOX WAY 930 NORTH MERIDIAN FORT WAYNE, IN 46804 INDIANAPOLIS, IN 46204 voice 260.432.9337 voice 317.917.1190 fax 260.436.2402 fax 317.822.6236 http://www.msktd.comrn CERTIFICATION R4ii No. O.00 * ; 19600471 I; -A STATE OF 4 _ �T ••. I'VD I ANP 0 Z111iS,SPNAL ••��`���``` The concepts, ideas, designs, plans, and details as shown on this document are the sole property of MSKTD & Associates, Inc., and were created, developed and presented for use on this specific project. None of the concepts, ideas, designs, plans, and details shall be used by any person, firm, or corporation for any purpose whatsoever, without the expressed written consent of MSKTD & Associates, Inc. The Owner shall be permitted to retain copies for information and reference in connection with this project. Revisions: Date: By: EET TITLE First Floor Lighting COMMISSION NUMBER DATE MSKTD 5629 2-11-11 BUILD 65076 11 1 SHEET NUMBER NE3 • LIGHTING PLAN NOTES 1 2 Provide JB with power and switch leg for Driveup signage provided by others. Power from circuit Em -18. Coordinate exact placement with signage supplier. Provide switch box(es) for control of Driveup signage. Coordinate exact requirement with signage supplier. 3 Provide ceiling mounted occupancy sensor. Tie to lighting control panel such that lighting is controlled by occupancy sensor during off hours. 4 Circuit emergency fixtures in restrooms to be controlled by occupancy sensor but in the event of loss of power, fixture is energized by the battery pack. 5 Connect exit signs and nightlights to circuit EM -13. 6 Wire conference rooms and public meeting rooms such that ceiling occupancy sensor is in series with wall mounted lighting controls and undercabinet light. Power to lighting to be automatically interrupted when rooms are unoccupied. 7 Provide inverter Bodine # ELI -100 -SD or approved equal to power Facade/Egress lighting at front entrance. — — 2 8 Provide self-contained lighting panel with integral time clock, control relays, and modem capable of accepting inputs from photocells and switches and with full programing capability. LC & D GR14016 or approved equal. Provide master override switches for all relays and exterior mounted photocell on north side of building. 9 Provide power feed to sign lighting. Coordinate exact location and requirements with sign supplier and architect. 10 Interlock undercabi net light such that power is switched off to fixture via occupancy sensor in ceiling. __0 10 MSKTD & Associates, Inc. ARCHITECTURE ENGINEERING INTERIOR DESIGN 1715 MAGNAVOX WAY 930 NORTH MERIDIAN FORT WAYNE, IN 46804 INDIANAPOLIS, IN 46204 voice 260.432.9337 voice 317.917.1190 fax 260.436.2402 fax 317.822.6236 http://www.msktd.comrn CERTIFICATION R4ii No. O.00 * ; 19600471 I; -A STATE OF 4 _ �T ••. I'VD I ANP 0 Z111iS,SPNAL ••��`���``` The concepts, ideas, designs, plans, and details as shown on this document are the sole property of MSKTD & Associates, Inc., and were created, developed and presented for use on this specific project. None of the concepts, ideas, designs, plans, and details shall be used by any person, firm, or corporation for any purpose whatsoever, without the expressed written consent of MSKTD & Associates, Inc. The Owner shall be permitted to retain copies for information and reference in connection with this project. Revisions: Date: By: EET TITLE First Floor Lighting COMMISSION NUMBER DATE MSKTD 5629 2-11-11 BUILD 65076 11 1 SHEET NUMBER NE3 •