Loading...
HomeMy WebLinkAbout51WALL SWITCH HOT - INVERTER CONNECTOR TEST BUZZER SWITCH SELECTOR CHARGING INDICATOR (CAP UNUSED LEAD) COMMON Lighting Control Schedule Electrical Symbols Circuit Load Power Symbols 1 Lighting Symbols Site (Pole) Lighting for Security Panelboard; see schedule for details O L-15,17 Site (Pole) Lighting for Operation Variable Frequency Drive 0 L-13 ®� Combination Starter; see schedule for details (2) EM -18 Facade Lighting & Canopy over ATM Nonfused Disconnect; see schedule for details 5 Light Fixtures; see schedule for details �u Fused Disconnect; see schedule for details 6 L-10 $T/P Manual Starter w/ Pilot & Thermal _ L-5 Lobby Duplex Receptacle - Emergency a Single Pole Light Switch; is leg Sign Light - South Quadplex Receptacle 9 a switch Sign Light - East Duplex Receptacle 3 Three-way Light Switch Sign Light - North Duplex Receptacle; Horizontal Mount $4 Four-way Light Switch IG 4�r= Duplex Receptacle, Isolated Ground $D Dimmer Switch GFCI Duplex Receptacle, Ground Fault Circuit Interrupt $ K Key Operated Switch +� Special Receptacle; see drawings $ M Q� Momentary Switch Q Junction Box DLV Low Voltage Switch T Type F02 $P Single Pole Switch with Pilot Light Eff. % Fire Alarm Symbols OS Ceiling Mounted Occupancy Sensor - Line Voltage FACP Fire Alarm Control Panel (EDL Ceiling Mounted Occupancy Sensor - Low Voltage FAAP Fire Alarm Annunciator Panel Q Wall Mounted Occupancy Sensor - Line Voltage F❑ Manual Pull Station 0 L Wall Mounted Occupancy Sensor - Low Voltage 83.8 Fire Alarm Speaker/Strobe - Wall Mounted ® Universal Mount Exit Sign - Single Face 1 Fire Alarm Strobe - Wall Mounted 0.88 Universal Mount Exit Sign - Double Face 0 Smoke Detector - Duct Mounted Alternate2 3 GC8 O Smoke Detector Ceiling Mounted Communication Symbols - Communications Outlet SQ Box Thermal Detector - Duct Mounted (4" w/Single Gang Ring) O Thermal Detector - Ceiling Mounted a Communications Outlet Floor Box; see schedule SOF Fire Alarm Speaker - Ceiling Mounted © Ceiling mounted clock 80 Motorized Smoke Damper 3 Wall mounted clock 1 Fire Alarm Bell V❑ Volume Control; mount at +48" AFF o -Q Flow Detector SQ Ceiling mounted speaker -� Tamper Detector a Wall mounted speaker HO Door Hold Open :D QWireless Input jack Access Point; mount 6" above ceiling Security Symbols ICM Intercom Station; M indicates Master Station CR Card Reader Lens, non air handling. Provide emergency battery pack. rMS1 Door Strike 3 Nurse Call Symbols vR Video Recorder �B Code Blue; mount at +48" AFF [TM_1 Video Monitor �C Sidecom/ Aux. jack; mount at +16" AFF MO Ceiling mounted motion detector -O Duty Station; mount at +48" AFF �/ Wall mounted motion detector 1 Emergency Pull Station; mount at +24" AFF 0 Door mounted security switch -O Nurse Station Console; mount at +16" AFF REX D Request To Exit Patient Bed Station; mount at +48" AFF CO Security camera; see specifications Pendant Staff Registration Station; mount at +48" AFF [CC=] Security camera in enclosure - sO Staff Assist Station; mount at +48" AFF Plan Note Symbols Dome Light DElectrical Demolition Notes Pinnacle Edge Series - OPower Plan Notes diffuser lens and spun metal trim ring; swivel O Lighting Plan Notes 6 36 FA I Communication Plan Notes 0.94 NOT ALL SYMBOLS MAY BE USED WALL SWITCH HOT - INVERTER CONNECTOR TEST BUZZER SWITCH SELECTOR CHARGING INDICATOR (CAP UNUSED LEAD) COMMON Lighting Control Schedule Relay # Circuit Load Control Scheme 1 L-16,18 Site (Pole) Lighting for Security Photocell 2 L-15,17 Site (Pole) Lighting for Operation Photocell plus Timer 3 L-13 Site Bollards Lighting for Operation Photocell plus Timer 4 EM -18 Facade Lighting & Canopy over ATM Photocell 5 EM -18 Canopy Lighting for Operation Photocell plus Timer 6 L-10 Common Hallway Timer plus Override Switches 7 L-5 Lobby Timer for Normal Operation/ Occupancy Sensor for Off Hours 8 L-11 Sign Light - South Photocell plus Timer 9 L-13 Sign Light - East Photocell plus Timer 10 L-14 Sign Light - North Photocell plus Timer 11 P1-26 I Exhaust Fan I Timer for Normal Operation/ Occupancy Sensor for Off Hours 12 Spare EMERGENCY BALLAST •v l\ V Y V I V 1- J BLACK 120V WARNING: DO NOT CONNECT BROWN CONNECTOR 3 -LAMP PROGRAM START BALLAST Three(3) Lamp Program Start Ballast NO SCALE LAMP 1 (EMERGENCY) LAMP 2 (EMERGENCY) I LAMP 3 1 EM Ballast WirinLa Diagram Not to Scale WALL 3/4" FLEX CONNECTION/ POWER J -BOX TO LOW WALL ,[ WALL OR FLOOR BOX r►/// n � - TELE/DATA J -BOX 1-1/4" FLEX CONNECTION TO LOW WALL �- LOW WALL OR SYSTEM FURNITURE System Furniture and Low Wall Feed Detail NO SCALE GENERAL NOTES - APPLY TO ALL SHEETS: 1. Installations shall conform with federal, state, and local laws, codes, ordinances, rules, and regulations which are hereby made a part of these contract documents the same as if repeated herein. 2. Contractor shall include in bid/proposal cost required to completely and properly install work required for the project. 3. Contractor shall include in bid/proposal cost for cutting and patching as required to install new or existing work, equipment or systems. 4. Clearances indicated are based on best available information. Contractor shall verify piping, ductwork, routing, and structural details prior to submitting a bid/proposal and include such costs as required to install work as shown and intended. 5. Verify all dimensions from architectural plans. 6. Fluorescent fixtures installed in acoustical tileshall be on one foot module. Fixtures installed in grid ceiling shall be equipped with safety chain (from two corners) connected to structural member above the ceiling. 7. Dimensions shown on outlet boxes shall be to the bottom of the box. 8. Conduit to lights is shown to indicate switching and does not indicate quantity or exact location. 9. Provide plaster rings where required by ceiling construction. 10. Verify location of lights in rooms containing exposed ductwork and piping with mechanical contractor and relocate as necessary and/or as directed by the engineer. 11. Contractor shall thoroughly examine the work of other contractors prior to submitting a bid/proposal. 12. Contractor shall coordinate and assure that no piping, ducts, or equipment foreign to electrical equipment shall be installed in, either, or pass through electrical spaces or rooms per NEC Article 408. 13. All power outages shall be coordinated and scheduled in advance with the owner. 14. Whereas plans generally show individual home run single phase branch circuits, contractor may run up to three (3) such circuits in a raceway. 15. Verify types of ceiling and dimensions before placing order for light fixtures. 16. Circuit numbers shown for existing panels are based on existing drawings, schedules, and field survey. Field verify as required. 17. Light fixtures to be reused shall be cleaned and relamped. Ballasts shall be replaced to match new fixtures. 18. Refer to site plan for additional electrical work. 19. Contract documents consist of both project manual and drawings and both are meant to be complementary. Anything appearing on either must be executed the same as if shown on both. 20. Some electrical work may be required to be performed off regular work hours. Cost for premium time shall be included in the bid/proposal. 21. Verify location of all outlets in equipment and built-in furniture with equipment supplier prior to roughing -in. 22. Verify location of all outlets at counter tops and cabinets with architectural elevation drawings prior to roughing -in. 23. All existing equipment that is to remain is intended to be operational at the completion of the job. This contractor shall recircuit where necessary to ensure this continued operation. MSKTD & Associates, Inc. ARCHITECTURE ENGINEERING INTERIOR DESIGN 1715 MAGNAVOX WAY 930 NORTH MERIDIAN FORT WAYNE, IN 46804 INDIANAPOLIS, IN 46204 voice 260.432.9337 voice 317.917.1190 fax 260.436.2402 fax 317.822.6236 http://www.msktd.com CERTIFICATION \\\\\\\\111111' � ••�G\S TF,y, i Q i * 19600471 ;-•: STATE OF • �.c`• •. INDIANP .0 c 7CNAL�•����`��`` 111111\\\\\\\ The concepts, ideas, designs, plans, and details as shown on this document are the sole property of MSKTD & Associates, Inc., and were created, developed and presented for use on this specific project. None of the concepts, ideas, designs, plans, and details shall be used by any person, firm, or corporation for any purpose whatsoever, without the expressed written consent of MSKTD & Associates, Inc. The Owner shall be permitted to retain copies for information and reference in connection with this project. Revisions: Date: By: SHEET TITLE Symbols and Fixture Schedule COMMISSION NUMBER DATE MSKTD 5629 2-11-11 BUILD 65076 11 1 FS HEET NUMBER 502 Fixture Detail LUMINAIRE SCHEDULE Lamp Detail Ballast Detail Min. Min. T Type F02 Mount Recess Description General Eff. % Description Qty Wattage Qty Start Type BF Max THD % Start Temp. OF Input Wattage ; Basis of Design purpose specification grade lensed troffer, 2' x 4'. Grid mount. Flush steel door. 83.8 T8; 24,000HR; 2950 Lumens 2 32 1 Program Start 0.88 10 0 Alternate 1 56 VA DayBrite SPG Series Alternate2 3 GC8 COUnt #12 pattern acrylic lens, .125" thick. Initial; 3500°K; 85CRI. Columbia ST8 Series I i Lithonia Metalux Series 4 F05 Recess Basket Style fixture, 2'x2', Recessed Satine Lens, non air handling. 80 T8; 24, 1400 Lumens 3 17 1 Program Start 1.01 10 0 54 VA Pinnacle ADEO AD22A F05E Recess Basket Style fixture, 2'x2', Recessed Satine 80 l; 350 Initial; 3500°K; 85CRI. T8; 24,OOHR; 1400 Lumens ; Lithonia Avante Series Metalux Ovation Series Day -Brite Perform Series 113 Lens, non air handling. Provide emergency battery pack. Initial; 3500°K; 85CRI. 3 17 1 Program Start 1.01 10 0 54 VA Pinnacle ADEO AD22A Lithonia Avante Series Metalux Ovation Series Day -Brite Perform Series 6 F06 Recess Narrow 3" slot T5 fluorescent with concave 62 T5; 25,000HR; 1350 Lumens 1 54 1 Program Start 1 10 F07 Pendant parobolic louver Shallow decorative bowl with white opal 72 Initial; 3500°K; 82 CRI. _2G1 0 57 VA Focal Point Avenue B Series Day -O -Lite PTP44 Series Pinnacle Edge Series - 18 diffuser lens and spun metal trim ring; swivel CFL Long; 4 pin; 1 Base; 15,000HR; 2900 Lumens 6 36 3 Program 0.94 10 0 207 VA Advent AIP8509 Series OCL Horizon HR1 Series - canopy; 5/8" metal stem; OAH 41.7in. Initial; 3500°K; 82CRI. 1 F07E Pendant Shallow decorative bowl with white opal diffuser 72 CFL Long; 4 pin; 2G11 Base; 6 36 3 Program 0.94 10 lens and spun metal trim ring; swivel 15,000HR; 2900 Lumens 0 207 VA 'Advent Al8509 Series OCL Horizon HR1 Series - canopy; 5/8" metal stem; OAH 41.7in. Provide Initial; 3500°K; 82CRI. I 1 Emergency Battery Pack. F08 Pendant Shallow decorative bowl with white opal diffuser lens and spun metal trim ring; swivel 72 CFL Long; 4 pin; 2G11 Base; 15,000HR; 2900 Lumens 2 36 1 Program 0.94 10 0 69 VA ',Advent AIP8508 Series OCL Horizon HR -1 Series -- canopy; 5/8" metal stem; OAH 41.7in. Initial; 3500°K; 82CRI. 18 F08E Pendant Shallow decorative bowl with white opal diffuser lens and spun metal trim ring; swivel 72 CFL Long; 4 pin; 2G11 Base; 15,000HR; 2 36 1 Program 0.94 10 0 69 VA Advent AIP8508 Series canopy; 5/8" metal stem; OAH 41.7in. Provide 2900 Lumens Initial; 3500°K; 82CRI. OCL Horizon HR1 Series 1 emergency battery pack. F09 Wall Direct/indirect wall mount fixture. Brushed aluminum housing. Upper and lower acrylic 50 T8, 24000HR, 1400 Lumens Initial, 2 17 1 Program Start 0.88 10 0 29 VA 'Metalux BAU Series diffusers. 3500°K, 85CRI. Lithonia W Series 4 F10 Undercabinet Specification grade, solid front low profile 68 T8, 24000HR, 2950 Lumens 1 32 1 Program Start 0.92 10 undercabinet light, Oft nominal length. Rocker Switch. Initial, 3500°K, 85CRI. 0 29 VA Day -Brite 8UC Series Duray DSF Series Fail -Safe MAS Series Lithonia N2S Series 2 F11 Undercabinet Specification grade, solid front low profile undercabinet light, 3ft nominal length. Rocker 68 T8, 24000HR, 2225 Lumens Initial, 3500°K, 85CRI. 1 25 1 Program Start 0.92 10 0 22 VA Day -Brite 8UC Series Duray DSF Switch. Series Fail -Safe MAS Series Lithonia N2S Series 1 K01 Recess 6" Open Reflector LED Downlight; Haze finish; 80 Integral LED; 3500°K; 80CRI. 1 25 1 N/A White painted flange; Dimmable. 1500 1 10 -20 27 VA Portfolio LD615 Omega OM6LED Series Prescolite LF6LED Lumens Series Indy SDG Series 24 K02 Recess 6" Open Reflector LED Wallwash; Haze finish; White painted flange; Dimmable. 80 Integral LED; 3500°K; 80CRI. 1 25 1 N/A 1 10 -20 27 VA Portfolio LD615 1500 Lumens Omega OM6LED Series Prescolite LF6LED Series Indy SDG Series 12 K03 Recess Open Reflector LED Downlight; Haze finish; 80 Integral LED; 3500°K; 80CRI. 1 15 1 N/A W White painted flange; Dimmable. 900-1000 Lumens 1 10 20 18 VA Portfolio LD610 Omega OM6LED Series Prescolite LF6LED Series Indy SDG Series 35 K03E Recess 6" Open Reflector LED Downlight; Haze finish; 80 Integral LED; 3500°K; 80CRI. 1 15 1 N/A 1 10 White painted flange; Dimmable. 900-1000 Lumens. Provide emergency battery pack. 20 18 VA Portfolio LD610 Omega OM6LED Series Prescolite LF6LED Series Ind' y SDG Series 2 K04 :Recess 7" Recessed lens Vertical downlight. LI 87 70W PAR38 MH Flood 1 70 1 N/A reflector. 1 0 20 80 VA Portfolio MD7X Series Prescolite LF6MH K05 Wall Die cast aluminum quarter sphere fixture. Medium throw distribution; multi -volt. Include 25 .3 CFL Cluster; 4 pin; G24q Base; 12,000HR; 1800 2 26 1 Program Start 1 10 -20 52 VA 'Lithonia WSQ Series Devine BWD Series 7 remote mount emergency ballast. Color to be Lumens Initial; 3500°K; 82 Gardco 106 Series McGraw Edison ISS Series 1 selected. CRL K06 Wall Decorative Die-cast aluminum fixture. Forward 25.3 PSMH; Clear; Vertical; 1 150 1 f5ulse Start 1 throw Bronze distribution; multi -volt. Full Cutoff Color Cutoff Shield 24,000HR; 14,000 Lumens 10 -20 180 VA 'Hubbell Laredo Series Devine BWD Series Gardco 106 Series McGraw Edison ISS Series 1 Initial; I EMERGENCY BALLAST •v l\ V Y V I V 1- J BLACK 120V WARNING: DO NOT CONNECT BROWN CONNECTOR 3 -LAMP PROGRAM START BALLAST Three(3) Lamp Program Start Ballast NO SCALE LAMP 1 (EMERGENCY) LAMP 2 (EMERGENCY) I LAMP 3 1 EM Ballast WirinLa Diagram Not to Scale WALL 3/4" FLEX CONNECTION/ POWER J -BOX TO LOW WALL ,[ WALL OR FLOOR BOX r►/// n � - TELE/DATA J -BOX 1-1/4" FLEX CONNECTION TO LOW WALL �- LOW WALL OR SYSTEM FURNITURE System Furniture and Low Wall Feed Detail NO SCALE GENERAL NOTES - APPLY TO ALL SHEETS: 1. Installations shall conform with federal, state, and local laws, codes, ordinances, rules, and regulations which are hereby made a part of these contract documents the same as if repeated herein. 2. Contractor shall include in bid/proposal cost required to completely and properly install work required for the project. 3. Contractor shall include in bid/proposal cost for cutting and patching as required to install new or existing work, equipment or systems. 4. Clearances indicated are based on best available information. Contractor shall verify piping, ductwork, routing, and structural details prior to submitting a bid/proposal and include such costs as required to install work as shown and intended. 5. Verify all dimensions from architectural plans. 6. Fluorescent fixtures installed in acoustical tileshall be on one foot module. Fixtures installed in grid ceiling shall be equipped with safety chain (from two corners) connected to structural member above the ceiling. 7. Dimensions shown on outlet boxes shall be to the bottom of the box. 8. Conduit to lights is shown to indicate switching and does not indicate quantity or exact location. 9. Provide plaster rings where required by ceiling construction. 10. Verify location of lights in rooms containing exposed ductwork and piping with mechanical contractor and relocate as necessary and/or as directed by the engineer. 11. Contractor shall thoroughly examine the work of other contractors prior to submitting a bid/proposal. 12. Contractor shall coordinate and assure that no piping, ducts, or equipment foreign to electrical equipment shall be installed in, either, or pass through electrical spaces or rooms per NEC Article 408. 13. All power outages shall be coordinated and scheduled in advance with the owner. 14. Whereas plans generally show individual home run single phase branch circuits, contractor may run up to three (3) such circuits in a raceway. 15. Verify types of ceiling and dimensions before placing order for light fixtures. 16. Circuit numbers shown for existing panels are based on existing drawings, schedules, and field survey. Field verify as required. 17. Light fixtures to be reused shall be cleaned and relamped. Ballasts shall be replaced to match new fixtures. 18. Refer to site plan for additional electrical work. 19. Contract documents consist of both project manual and drawings and both are meant to be complementary. Anything appearing on either must be executed the same as if shown on both. 20. Some electrical work may be required to be performed off regular work hours. Cost for premium time shall be included in the bid/proposal. 21. Verify location of all outlets in equipment and built-in furniture with equipment supplier prior to roughing -in. 22. Verify location of all outlets at counter tops and cabinets with architectural elevation drawings prior to roughing -in. 23. All existing equipment that is to remain is intended to be operational at the completion of the job. This contractor shall recircuit where necessary to ensure this continued operation. MSKTD & Associates, Inc. ARCHITECTURE ENGINEERING INTERIOR DESIGN 1715 MAGNAVOX WAY 930 NORTH MERIDIAN FORT WAYNE, IN 46804 INDIANAPOLIS, IN 46204 voice 260.432.9337 voice 317.917.1190 fax 260.436.2402 fax 317.822.6236 http://www.msktd.com CERTIFICATION \\\\\\\\111111' � ••�G\S TF,y, i Q i * 19600471 ;-•: STATE OF • �.c`• •. INDIANP .0 c 7CNAL�•����`��`` 111111\\\\\\\ The concepts, ideas, designs, plans, and details as shown on this document are the sole property of MSKTD & Associates, Inc., and were created, developed and presented for use on this specific project. None of the concepts, ideas, designs, plans, and details shall be used by any person, firm, or corporation for any purpose whatsoever, without the expressed written consent of MSKTD & Associates, Inc. The Owner shall be permitted to retain copies for information and reference in connection with this project. Revisions: Date: By: SHEET TITLE Symbols and Fixture Schedule COMMISSION NUMBER DATE MSKTD 5629 2-11-11 BUILD 65076 11 1 FS HEET NUMBER 502