Loading...
HomeMy WebLinkAbout4ANCHOR VERTICALS O STRUCTURE ABOVE (UNO) EXISTING CEILING TO REMAIN EL +9'-4" AFF REWORK EXISTING CEILING AS REQUIRED TO ACCOMMODATE NEW CONSTRUCTION NEW BULKHEAD W/ 5/8" GWB ON 3 5/8" - STEEL STUDS O 16" OC TYPICAL EXISTING CEILING TO REMAIN EL +9'-4" AFF REWORK EXISTING CEILING AS REQUIRED TO ACCOMMODATE NEW CONSTRUCTION td - B./ GWB r, EL +9'-0- AFF --FACE OF WALL BEYOND 6" 1 DETAIL 3/4" = 1'-0" ANCHOR VERTICALS O STRUCTURE ABOVE (UNO) EXISTING CEILING TO REMAIN - EL +9'-4" AFF REWORK EXISTING CEILING AS REQUIRED TO ACCOMMODATE NEW CONSTRUCTION it NEW BULKHEAD W/ 5/8' GWB ON 3 5/8" - STEEL STUDS O 16' OC TYPICAL FINISH CEILING - REFER TO REFLECTED CEILING PLAN EL +10'-4" AFF LXZJ B./ GWB EL +9'-0' AFF 6" 2 DETAIL 3/4' = 1'-0- PR -O" PR 0 DUCT/FINI SH LIST ING PRODUCT NUMBER DESCRIPTION MANUFACTURER MODEL NUMBER REMARKS ROOMS ACT1 ACOUSTICAL CEILING TILE AND GRID (2x2) ARMSTRONG 1728, FINE FISSURED,SQ.LAY-IN GRID: MATCH EXSITING 606/GEN REPAIRS RB -1 RUBBER BASE JOHNSONITE #18, NAVY BLUE - 505/507/507A RB -2 RUBBER BASE JOHNSONITE #76, CINNAMON - 407/506/606 PT PAINT MPI APPROVED PRODUCT COLOR TO MATCH EXISTING, INCL PRIME, INTERMEDIATE AND TOP COAT PAINT CODE 4.14 (SEMI -GLOSS) 407/505/507/507A/ 506/506A/606/500 VCT VINYL COMPOSITION TILE ARMSTRONG 52513, CIRQUE WHITE "STD. EXCELON" 606(FLR ONLY) DET DETENTION WALL PADDING MARATHON ENGINEERING CORP. GOLD MEDAL RESILIENT PADDING ON WALLS AND DOOR 507A RSF RESILIENT FLOORING MONDO MARINE BLUE RAMFLEX 505/507/507A CAR CARPET (CARPET SQUARES) COLLINS / AIKMAN MOONSTONE 23603 CALYPSO 407/506/506A/606(AT STAIRS ONLY) RSA RESILIENT STAIR ACCESSORIES JOHNSONITE #76, CINNAMON STAIR NOSINGS 606 FAC FIRE ALARM PULL STATION COVER EST STI SERIES STOPPER II STI_ 1100 FLUSH MTD W/ SPACER (STI -3100) 500 LF -1 VANDAL RESISTANT LIGHT FIXTURE LITHONIA VSL 2 32 SCEMVOLT GEB10 IS 60W 507A NOTE: PRODUCTS LISTED ARE INTENDED TO MATCH EXISTING FINISHES. IF FINISHES OTHER THAN THOSE INDICATED ARE NEEDED, PLEASE NOTIFY. DOOR AND FRAME SCHEDULE DOOR NUMBER DOOR FRAME Q FIRE RATING IN MINS. HARDWARE STC RATING1 REMARKS (SEE GENERAL NOTES AND LEGEND) MAT. TYPE JAMB DEPTH DETAILS SIZE MAT. TYPE HEAD JAMB SILL SET NO. KEYSIDE ROOM NO. 505-A 3'-0" x 7'-2" WD G HM F1 5 3/4" H2 J2 - - 2 1 MOP PLATE - PL 507-A 3'-0" x 7'-2" WD N HM F1 5 3/4" H2 J2 - - 1 1 WALL BUMPER - 630 606-A 3'-0" x 7'-2" WD G HM F1 5 3/4" H2 J2 - - 3 1 CLOSER - 689 606-B 3'-0" x 7'-2" WD N HM F1 5 3/4" H2 J2 - - 4 - HARDWARE SETS rrEM PART NUMBER FINISH HARDWARE SET #1: - DOOR 507A Q NO. 3 HINGES AB700 4.5x4.5 652 1 REVERSE HOSPITAL PUSH LATCH 6830 SERIESxPUSH LEVER UP 626 1 KICK PLATE 1 10"x2LDWx.125 (PULL SIDE) PL 1 WALL STOP 475 626 HARDWARE SET #2: - DOOR 505A 2050 SF - 3HINGES AB700 4.5x4.5 652 1 PASSAGE SET 8215xLNE 626 1 CLOSER WITH STOP 1 4041 XP CUSHxTB 689 1 KICK PLATE 10'x2LDWx.125 PL 1 MOP PLATE 4"x2LDWx.125 PL HARDWARE SET #3: - DOOR 606A 507A TIME OUT 3HINGES AB700 4.5x4.5 652 1 PASSAGE SET 8215xLNE 626 2 MOP PLATES 4"x2LDWx.125 PL 1 WALL BUMPER 406 630 HARDWARE SET #4: - DOOR 606B 3 HINGES AB700 4.5x4.5 652 1 LOCKET 8237xLNE 626 1 CYLINDER W/ IC KEYED BY OWNER 626 1 CLOSER 4041 XP EDAxTB 689 1 KICK PLATE 10"x2LDWx.125 PL 1 MOP PLATE 4"x2LDWx.125 PL 1 WALL BUMPER 406 630 ....__._... .............. L- - II II FIRST FLOOR REFLECTED CEILING PLAN 1/8" = 1'-0" I I I I I 1/8w = 1'-0" ROOM LEGEND ROOM ® LIGHT REFER TO ELECTRICAL DRAWINGS Q NO. ROOM NAME AREA CLNG HT 407 CLASSROOM 983 SF 9'-4" 407A TIME OUT 55 SF - 500 CORRIDOR 2050 SF - 505 FOCUS AREA 227 SF 9'-4" 506 CLASSROOM 852 SF 9'-4" 506A SENSORY RM 35 SF - 507 ALCOVE 62 SF - 507A TIME OUT 32 SF - 606 FITNESS 358 SF 9'-4" REFLECTED PLAN GENERAL NOTES A. THE ARCHITECTURAL REFLECTED CEILING PLANS GOVERN THE LAYOUT OF ALL CEILING ELEMENTS/PENETRATIONS. REFLECTED CEILING PLAN LEGEND EO LIGHT REFER TO ELECTRICAL DRAWINGS ® LIGHT REFER TO ELECTRICAL DRAWINGS Q UGHT REFER TO ELECTRICAL DRAWINGS Z RETURN AIR GRILL REFER TO MECHANICAL DRAWINGS ® DIFFUSER REFER TO MECHANICAL DRAWINGS Os SPEAKER REFER TO ELECTRICAL DRAWINGS (s SMOKE DETECTOR REFER TO ELECTRICAL DRAWINGS or HEAT DETECTOR REFER TO ELECTRICAL DRAWINGS ® CEILING MOUNTED EXff LIGHT 2x4 ACOUSTICAL CEILING EATER REFER TO MECHANICAL DCABINIET RAWINGS INDICATES GWB BULKHEAD/CEILING REFLECTED PLAN KEY NOTES Q 1. EXISTING CEILING FINISH TO REMAIN. 2. THIS AREA TO BE REWORKED AS REQUIRED TO PROVIDE FINISH EDGE AGAINST NEW WALL REUSE EXISTING GRID AND CEILING TILES AS REQUIRED. 3. REWORK DUCTWORK TO ACCEPT RELOCATED DIFFUSER IN NEW LOCATION AS SHOWN. PROVIDE FLEX DUCTWORK TO EXTEND DUCTWORK TO NEW DIFFUSER LOCATION. 4. REWORK ELECTRICAL TO ACCEPT RELOCATED LIGHT FIXTURE IN NEW LOCATION AS SHOWN. SECURE LIGHT FIXTURE FROM ALL FOUR CORNER`, TO STRUCTURE ABOVE. 5. GWB BULKHEAD - REFER TO 1-A1.2 6. GWB BULKHEAD - REFER TO 2-A1.2. 7. REWORK ELECTRICAL TO ACCEPT NEW VANDAL PROOF LIGHT FIXTURE IN LOCATION AS SHOWN. SECURE LIGHT FIXTURE FROM ALL FOUR CORNER! TO STRUCTURE ABOVE. REFLECTED PLAN DEMO KEY NOTESI 1. REMOVE DIFFUSER AND SALVAGE FOR REINSTALLATION IN NEW CONSTRUCTION. 2. REMOVE LIGHT FIXTURE AND SALVAGE FOR REINSTALLATION IN NEW CONSTRUCTION. 3. REMOVE EXISTING ACT TILES, SUPPORT ANY CEILING MOUNTED ITEMS AND REWORK CEILING GRID AS SHOWN IN NEW CONSTRUCTION. PROT CEILING GRID TO REMAIN. 4. REMOVE LIGHT FIXTURE. VERIFICATION NOTE CONTRACTOR SHALL VERIFY ALL DIMENSIONS AND CLEARANCES AND ALL EXISTING FIELD CONDITIONS BEFORE STARTING CONSTRUCTION. COMMENCEMENT OF WORK CONSTITUTES ACCEPTANCE OF CONDITIONS. SHOULD DIFFERENT CONDITIONS BE ENCOUNTERED, CONTACT THE ARCHITECT BEFORE PROCEEDING WITH WORK. z 46 W t V O co co 3 O z z z < sm 0 r Co N 0 v no KEY PLAN O V S O � 3 � 3 V � 0141 � o Z 7, co r M II - co J Z < v d Z w J SL W ad V D J V LuW J V IUL co W Q = co Z CARMEL MIDDLE SCHOOL 211141.00 N T Q t•. . �>2- /�.. no KEY PLAN O V S O � 3 � 3 V � 0141 � o Z 7, co r M II - co J Z < v d Z w J SL W ad V D J V LuW J V IUL co W Q = co Z CARMEL MIDDLE SCHOOL 211141.00 N T Q