Loading...
HomeMy WebLinkAboutA016ARCHITECTURAL 5H INOLE5TO MATCH EXI5TING 5YNTH ETICUNDERLAYMENT 1/16" 05B ROOF DECKING WITH H-CLIP5 H IF5C155OR TRU55E5 @ 24" 0/0 1X4 T&O PINE CEILING 51MP50N 5TRONO-TIE (OR EQUIV) RAFTER 5TRAPANCHOREDTO BEAM 2X 5UBFA5CIA 6" ALUMINUM OUTTERTO MATCH EXI5TING 1X6 R/5CEDARFA5CIATOMATCH EX15TINO 3/8" R/5 FIR PLYWOOD 5OFFIT TO MATCH EX15TINO 1X2 R/5 CEDAR OVER 1X6 R/5 CEDAR FRIEZE BOARD TO MATCH EX15TINO 2X BLOCKING ON FACE OF BEAMS TO CREATE FIN15H EDBEAM WIDTH OF q-3/4" (TYP. BOTH 51DE5 OF BEAM) 1X6 R/5 CEDAR COLUMN TRIM (TYP. ALL 51DE5) 51MP50N 5TRONO-TIE(OR EQUIV) BEAM BRACKET ANCH OREDTO P05T 1X R/5 CEDAR BEAM WRAP TRIM (TYP. ALL 51DE5) 1X2 R/5 CEDAR TRIM (TYP.CEILINO/WALL PERIMETER) TREATED 6X6 COLUMN 1X8 R/5 CEDAR COLUMN WRAP, RIPPED DOWN A5 NECE55ARY 1X8 R/5 CEDAR COLUMN BA5E TRIM 1X4 R/5 CEDAR COLUMN BA5E TRIM PAVER Y MIN. COMPACTED GRAVEL BA5E 51MP50N 5TRONO-TIE (OR EQUIV) P05T BRACKET ANCHOREDTO CONCRETE PIER 18"M X 36" D CA5T-IN-PLACE CONCRETE PIER (Ai WALL SECTION RELEASED IFCR CONSTRICTION I5uhj ©r1Na IL L�. I J //^f aI IC'It of�'.airrnel ° 1t)ATLE a 025/18 r . Adam Schriner 2X4 BLOCKING BETWEEN TRU55E5 A5 NECE55ARY 1X4 T&O PINE CEILING ATTACHED TO 2X4 FRAMING 2x4 WALL, FRAMED BETWEEN TRU55E5, BEARING ON BEAM BELOW 1X2 R/5 CEDAR TRIM (TYP.CEILINO/WALL PERIMETER) 2X BLOCKING ON FACE OF BEAMS TO CREATE F IN15H EDBEAM WIDTH OF q-3/4" (TYP. BOTH 51DE5 OF BEAM) 1X6 R/5 CEDAR COLUMN TRIM (TYP. ALL 51DE5) 51MP50N 5TRONO-TIE (OR EQUIV) BEAM BRACKET ANCHOREDTO P05T 1X R/5CEDAR BEAM WRAPTRIM (TYP.ALL 51DE5) 1X2 R/5 CEDAR TRIM (TYP.CEILINO/WALL PERIMETER) TREATED 6X6 COLUMN 1X8 R/5 CEDAR COLUMN WRAP, RIPPED DOWN A5 NECE55ARY 1X8 R/5 CEDAR COLUMN BA5E TRIM MN BA5E TRIM PAVER W MIN. COMPACTED ORAVELBA5E 51MP50N 5TRONO-TIE (OR EQUIV) P05T BRACKET ANCHOREDTO CONCRETE PIER 18"M X 36" D CA5T-IN-PLACE CONCRETE PIER © WALL SECTION www.caseind .com 99 E. Carmel Drive, Suite 100 Carmel, Indiana 46032 317.846.2600 317.846.2601(f Dave Null Lead Designer dnull@caseindy.com Craig Dice Designer cdice@caseindy.com Approved By: Date: These drawings have been prepared by Case Design & Remodeling solely for Its use and should not be reproduced or relied upon by any other parties. Dlmenslons shown or scaled are subject to change per actual job condition and must be verified. Mater lals are to be supplied as specified as equal or standard when not uniquely specified. Installed materials may vary In appearance from drawings. Reference manufacturer's product data for actual appearance and specifications. O A' ■ — W V 'G A� W ■ V/ ■� > O CC J aL p1S,M .(M 0O T) m g " 3°C�0E L L V) O ��u Revision: Date: #1 03.02.18 #2 03.14.18 #3 06.04.18 FINAL Sheet: of Jm6 is