HomeMy WebLinkAbout50LEGEND DETAIL NUMBER e -_DETAIL SHEET S S INDICATES FOOTING STEP, SEE DETAIL D/S501. INDICATES CONCRETE WALL. INDICATES WOOD STUD WALL. INDICATES DEPRESSED SLAB, SEE ARCHITECTURAL PLANS. INDICATES WOOD ROOF OR FLOOR SHEATHING, SEE SCHEDULE B/S001 FC INDICATES SIDE WHERE INTERIOR WOOD WALL SHEATHING . IS TO BE INSTALLED. CJ INDICATES CONTROL JOINT Wx-x INDICATES WOOD WALL SEE SCHEDULE A/SO02. WC -x INDICATES WOOD COLUMN. SEE SCHEDULE B/SO02 A -x INDICATES HOLD-DOWN TYPE, SEE SCHEDULE A/SO04. CW -x INDICATES CONCRETE WALL. SEE SCHEDULE C/S003. CW-x/Wx-x INDICATES CONCRETE WALL BELOW WOOD WALL. SEE SCL SCHEDULES C/SO03 AND A/S002. FC INDICATES CONCRETE CONTINUOUS FOOTING TYPE, SEE SCHEDULE A/SO03. FS INDICATES CONCRETE SPOT FOOTING TYPE, SEE 0 SCHEDULE A/SO03. FR INDICATES CONCRETE RECTANGULAR FOOTING TYPE, SEE SCHEDULE A/SO03. DP -x INDICATES CONCRETE DRILLED PIER, SEE DETAIL B/S502 BM -x INDICATES WOOD BEAM. SEE SCHEDULE C/SO02. SCL INDICATES STRUCTURAL COMPOSITE LUMBER SUCH AS LVL AND LSL. T.O.W. TOP OF WALL B.O.B. BOTTOM OF BEAM BLIBTft INDICATES FLOOR OFFSET, SEE DETAILS. 111111111 ROSTRUM/PLATFORM NOTES NOTES: 1. SEE DETAIL A/S521 FOR TYPICAL TOP PLATE SPLICE DETAIL 2. SEE SCHEDULE C/SO02 FOR BUILT-UP BEAM DETAIL. 3. SEE SCHEDULE ON SHEET S001 FOR WALL, ROOF, AND FLOOR NAILING REQUIREMENTS. EQUIPMENT PLATFORM FRAMING NOTES NOTES: 1. SEE ARCHITECTURAL PLANS FOR EQUIPMENT PLATFORM ELEVATIONS AND STEPS. 2. SEE DETAIL B/S521 FOR TOP PLATE SPLICE DETAIL FOR PIPES THAT PENETRATE TOP PLATES. 3. SEE SCHEDULE ON SHEET S001 FOR WALL, ROOF AND FLOOR NAILING REQUIREMENTS. 4. SEE DETAIL A/S521 FOR TYPICAL TOP PLATE SPLICE DETAIL. 5. SEE SCHEDULE C/SO02 FOR BUILT-UP BEAM DETAIL 6. SEE C/S521 AND D/S521 FOR DETAIL WHERE HVAC AIR DUCTS PENETRATE SHEAR WALLS. SEE MECH. SHEETS FOR LOCATION AND SIZES OF DUCTS. 7. FOR UNMARKED INTERIOR HEADERS, USE (3) 2x6 FOR 2x6 WALLS AND (2) 26 FOR 2x4 WALLS. USE (1) TRIMMER AND (1) KING STUD. FOOTING AND FOUNDATION NOTES NOTES: 1. TOP OF FOOTING 97'-6" TYPICAL UNLESS NOTED OTHERWISE AT ALL EXTERIOR FOOTINGS. 2. TOP OF FOOTING 99'-6" TYPICAL UNLESS NOTED OTHERWISE AT ALL INTERIOR FOOTINGS 3. RECESS FOUNDATION WALL 8" AT DOORWAYS AND POUR SLAB THRU OPENING. SEE H/S501 4. THICKEN SLAB TO 1'-3" x 2'-6" SQUARE AT VOLLEYBALL POST SLEEVE, SEE ARCH 5. SEE DETAIL A/S501 AND B/S501 FOR PIPES PERPENDICULAR AND PARALLEL TO FOOTING 6. SEE DETAIL C/S501 FOR TYPICAL CORNER WALL REINFORCING AT CONCRETE WALLS 7. SEE DETAIL D/S501 FOR TYPICAL FOOTING STEP DETAILS 8. SEE B/S001 FOR WALL/ROOF/FLOOR SHEATHING REQUIREMENTS 9. SPIKE BUILT-UP COLUMNS TOGETHER. SEE B/SO02 FOR DETAIL 10. SEE DETAIL E/S501 FOR TYPICAL SILL PLATE BOLTING DETAIL 11. DEPRESS FLOOR SLAB 2" FOR TILE/WOOD FLOOR SYSTEM. SEE F/S501 AND R/S501 FOR DETAIL AT STEP IN SLAB. SEE ARCH FOR DIMENSIONS AT ROOMS THAT REQUIRE TILE OR WOOD FLOOR. 12. BLOCK OUT FOR THRESHOLD AT DOOR. VERIFY SIZE WITH TILE INSTALLER 13. NO CONSTRUCTION OR CONTRACTION JOINTS SHALL BE ALLOWED IN THE BUILDING FLOOR SLAB UNLESS APPROVED BY THE ARCHITECT 14. CONCRETE PADS SUPPORTING A SATELLITE DISH IN THE MECHANICAL ENCLOSURE (WHERE OCCURS) TO BE INCREASED TO 5" THICK. COORDINATE WITH ARCH 15. REFER TO WALL AND PARTITION TYPES ON A103 FOR ADDITIONAL FRAMING REQUIREMENTS 16. ALL GRID DIMENSIONS ARE TO FACE OF STUD, TYPICAL U.N.O. 17. 4" CONCRETE SLAB ON GRADE WITH 7 1/2' POUNDS OF HIGH VOLUME SYNTHETIC FIBER (HVSF) REINFORCING PER CUBIC YARD OF CONCRETE. CONTRACTOR HAS OPTION TO REPLACE HVSF WITH 13 BARS AT 18" O.C. EA WAY 18. SEE DETAIL X/S502 FOR STRUCTURAL FILL BENEATH FOOTINGS AND THICKENED SLABS ROOF FRAMING NOTES NOTES: 1. SEE DETAIL A/S521 FOR TYPICAL TOP PLATE SPLICE DETAIL. 2. SEE SCHEDULE C/SO02 FOR BUILT-UP BEAM DETAIL 3. SEE DETAIL B/S521 FOR TOP PLATE SPLICE DETAIL FOR PIPES THAT PENETRATE TOP PLATES. 4. SEE DETAILS C/S521 AND D/S521 FOR SHEAR WALL PENETRATIONS. 5. SEE SCHEDULE ON SHEET S001 FOR WALL, ROOF, AND FLOOR NAILING REQUIREMENTS. 6. CENTERLINE OF FOLDING PARTITION. SEE ARCH FOR HEADER DETAIL 7. SEE THE S200 SERIES SHEETS FOR TRUSSED RAFTER SECTIONS. 8. SEE DETAIL E/S521 FOR TYPICAL CORNER SOFFIT. 9. REMOVE ROOF SHEATHING UNDER OVERBUILD FOR MECHANICAL DUCT ACCESS, OVERBUILD TRUSSES SHALL BE BUILT TO ALLOW DUCTS TO PASS THRU SEE MECHANICAL DRAWINGS. 10. (NOT USED) 11. CUT END OF BEAM AT A SLOPE TO MATCH ROOF SLOPE. SNOW DRIFT LEGEND ® INDICATES AREA OF SNOW DRIFT INDICATES ADDITIONAL LOADING DUE X ` TO SNOW DRIFT (SEE NOTE #1). Y X = LOAD AT DRIFT HIGH POINT Y = LENGTH OF DRIFT INDICATES ADDITIONAL LOADING DUE X _ X TO SNOW DRIFT (SEE NOTE #1). Y X = LOAD AT DRIFT HIGH/LOW POINT Y = LENGTH OF DRIFT 1. SEE PLAN FOR SNOW DRIFT LOADING. THESE LOADS ARE IN ADDITION TO THE TRUSS UNIFORM AND POINT LOADS SHOWN ON PLANS. TRUSS SUPPLIER TO ADD SNOW DRIFT LOAD TO TRUSS LOADS SHOWN ON S201 THRU S205. 9501 E. 86th St. Indianapolis IN (317) 849-6992 fax (317) 849-6993 103 Wind Haven Nkholsvllle KY (859)523-1500 fax(859)523-1514 Q w Z 0 Q 0 xx� F�--I O a V ZLr) 0 O oc 0 �..I Z �Z a H U �LU Z J LU Z CL J Cd a Q t U Z a W J � G W Z w C o Project Number: 50049487510 Plan Series: IPF -SC -10-04 Property Number: 500-4948 Sheet Title: STRUCTURAL SYMBOLS AND NOTES Sheet: S005 0 0 xx� U c �o UQ a V 0 Wo 0 t-1 Project Number: 50049487510 Plan Series: IPF -SC -10-04 Property Number: 500-4948 Sheet Title: STRUCTURAL SYMBOLS AND NOTES Sheet: S005 w 0 0 Ln 0 U �LU n L O - CD W C o N N } J J � D Fn N O Project Number: 50049487510 Plan Series: IPF -SC -10-04 Property Number: 500-4948 Sheet Title: STRUCTURAL SYMBOLS AND NOTES Sheet: S005