Loading...
HomeMy WebLinkAbout68A B C D E F G H EXTEND THIS LINE OVER D D OP DN TO SUPPLY CANOPY INSULATED AT ROOF TO MECHANICAL ACCESS S RINKLERS UNDER LEVEL AND INCLUDES AIR SPRINKLER LINE. SEE E UIPMENT PLATFORM TRANSFER GRILL SO PIPING D/FS201 FOR CONT. FLOOR SEE 3/FS201 FOR WILL NOT FREEZE. I I CONT. THIS AREA IS COVERED FROM E ABOVE - SEE 3/FS201 FS2 DROP DN SOU DER SUPPLY PLATFORM _ ffO- E E E - 4/FS201 -1-1 138 139 ` D` � El LTJ _J LTJ J S LYAIPMENT SPRINKLERS LT 1 LTLTJ LTJ J ....�.,, UNDER PLATFORM FLOOR - SEE •� 1 0 0 4/FS201 - r2- - • ...-------- ----------------------- 1 1 1 1 1 1 1\ 1 1 1 1 1 1 1 1 1 I I I 136 1 1 1 1 1 \ 11 1 1 1 11 1 1 1 1� I J" DROP DN TO SUPPLY SPRINKLERS UNDER SPEAKER CHAMBER L I -- I SPRINKLER HEAD �� U I L r l I I I I I I I �F_� 1 1 INSIDE SPEAKER F CHAMBER (TYP)II I� I I I I L_ JII I I I I I I I I I I I I I I I I I I 201 II I I I I I III I I I I I I $ INIfLE S UNDER I II AK R CHAMBERL-1 ❑ I I I I I 1 1 I I I I I I I FS2o1 1 131 I I I 1 FT -1 I I I I I I I I I I I II DROP DN TO L I I I I I I I I I I 1 1 1 1 1 SPRINKLER HEAD J \ II UNDER PLATFORM �\ \\ - Ltd----t--�Jt�t�t�t \ \ F rrT -T 135 I // / / //ISS t6p /F Olin /—= i KL�MAI ----rt------- I 140 I I ---;I- I I I I I I I I I I I I I I I I I I I I I I Stam THROUGHOUT LOWER PORTION OF BLDG. p��P�CIS'IDq I I I I I I I I I I STE'�Fq. I I IN EQUINENTI QIP PLIATIF AIN IN I I -1 -I-1 _P�AtEOW-F0QR4- - - I FLOOR FRAMI G LJ LJ ----------- I C3UQ J L1 1 41 O THIS AREA IS COVERED FROM I 1 148 162 ABOVE - SEE 3/FS201 132 .. I _ Jm Ilk I I I I I i I I I I 13o �FS21 EXTEN IS LINE OVER T MECH IAL ACCESS 131 I SPRIN LE LINE. SEE UPRIGH r SPRINKLER IN D/ CONTINUA 0 EQUIPM N PLATFORM �❑ L ------J - SEE 4 201 0 CANOPY CONSTRUCTED WITH FIRE RETARDANT PRESSURE TREATED I 6 - - f I� 1 I a LUMBER - NO AUTOMATIC ••••••••••••••••••......••••••• SPRINKLERS F F] 128 1 J_ 7 LTJ L4J L LvJ � A . FS201 0 F— — — — — — — — — — I I I 119 I 117 I I � I I LT L------- I ---� 0 129 O I I 0 0 109 I r i 0 0 0 L ,10 0 IF IIIA 1 L 108/► ......... ••..•.... '107 101 106 124A 123 I IL11 I 118 I Ell 104 125 ❑❑' ISE UP MTHIN RISER ROOM TS TS 100 ROP DOWN IN WALL TO TO 0 AFF, THEN OUT �� FS LT 115 114 (�� UPPLY DRY SIDEWALL - 1 ROUGH WALL, AND THEN I 'ks�J k'yJ 1 J L J RISE UP TO 8'-8" AFF IN ELEC I HORN /STROBE � � � OORDINATE WITH FRAMER 0 INSURE CLEARANCE. FOYER [101]. LOCATION. SEE SHEET FA101 6 A UNDERGROUND SUPPLY MAIN FS201 FS201 SHALL BE RUN TO 5'-0" UNDERGROUND FIRE DEPARTMENT OUTSIDE OF B IL IN FOR I I CONNECTION LINE SHALL BE RUN I CONNECTION Bf SITE TO 5'-0" DUTSIDE OF BUILDING -1, CONTRACTOR. SEE SITE PLAN FOR CONNECTION BY SITE FOR DETAILS AND CONTINUATION MAIN FLOOR PLAN CONTRACTOR. SEE SITE PLAN " f ff FOR DETAIL AND CONTINUATION 1/8 = 1 -0 B C D NORTH E 1246 TWO UPRIGHT SPRINKLERS IN EQUIPMENT PLATFORM - SEE 4/201 149 (......................... 0 155 156 ........0 ............. 164 157 158 I; ::dl l:F` + ARGO CONSULTING ENGINEERS, INC. 618 N. DAVIDSON STREET INDIANAPOUSa IN. 46202 PHONE: (317) 639-9244 FAX: (317) 639-9249 EMAIL: argo0argoce.com (D copyright 2012 Argo Conaulting Engineers, Inc. GENERAL NOTES 1. INSTALL FIRE PROTECTION PIPING AS SHOWN, WET -PIPE SYSTEM THROUGHOUT ALL AREAS OF THE BUILDING. 2. ATTIC IS CONSIDERED NON-COMBUSTIBLE DUE TO THE USE OF PRESSURE TREATED FIRE RETARDANT LUMBER. 2.1. THE ATTIC WILL NOT REQUIRE FIRE SPRINKLERS AS ALLOWED BY NFPA 13, 2 2.2. 8.15.1.2.11. SPRAY APPLICATION OF FIRE RETARDANT IS NOT ACCEPTABLE. 2.3. ALL TREATED LUMBER IS TO MEET THE REQUIREMENTS OF NFPA 703 FOR PRESSURE APPLIED FIRE RETARDANT TREATMENT. 3. USE DRY -BARREL TYPE SPRINKLERS IN COLD AREAS AND VESTIBULES WHEN SUPPLIED FROM WET SYSTEM. 4. OBTAIN APPROVAL FOR PIPING CHANGES FROM ARCHITECT AND ENGINEER. 5. RUN PIPING LEVEL OR SLOPED TO DRAIN AS DESIGNATED IN NFPA 13. 5.1. PIPE ELEVATION TO BE 8'-8" AFF Stam THROUGHOUT LOWER PORTION OF BLDG. p��P�CIS'IDq J 6 HE FIRE SPRINKLER P M SHALL BEa'•�.G\ STE'�Fq. HYDRAULICALLY DESIGNED PER THE No. REQUIREMENTS OF NFPA 13: 6.1. ORDINARY HAZARD GP 1 FOR 19524 : o MECHANICAL, ELECTRICAL, SERVING AREA, ��: STATE OF AND JANITOR AREAS. 6.2. ORDINARY HAZARD GP 2 FOR THE ��'�•••• ,,�Fs•,,D IA, �G�"S PLATFORM, IF AVAI. LTHEEREMAINDER �i,���s/ •• CO 6.3. LIGHT HAZARD FOR OF � THE BUILDING. n1117 11 7. SPRINKLER HEAD SPACING: L o cot 7.1. LIGHT HAZARD AREAS: 225 SQ. FT. 7.2. ORDINARY HAZARD AREAS: 130 SQ. FT. w 8. SEE SITE PLAN FOR UTILITY CONNECTION AND z (n LOCATION OF FIRE HYDRANTS AND POST INDICATING VALVE. Q H 0 9. DO NOT ROUTE PIPING THRU STRUCTURAL Z Q MEMBERS OR MECHANICAL DUCT WORK V EXCEPT AS SHOWN ON THE DRAWINGS. ZV 0 10. SPRINKLER HEADS ARE NOT REQUIRED TO BE IIZ � Q - - 3 CENTERED IN THE ONE FOOT ACOUSTICAL V) F-1 � 0 TILES. J �- 0 z � za 11. COORDINATE WITH FRAMER FOR SHEAR -WALL w 0 w PENETRATIONS. ALL SPRINKLERS SHALL BE g QUICK -RESPONSE TYPE. U) Q - 4 Q V 12. ALL WET -PIPE SYSTEM COMPONENTS Z w N (EXCEPT DRY BARREL SPRINKLERS) SHALL BE r, J INSTALLED INSIDE THE BUILDING .� INSULATION ENVELOPE. y^ 13. ALL REQUIRED DRAINS SHALL FOLLOW NFPA Ifl G 13 REQUIREMENTS. DRAIN VALVES SHALL BE z W LOCATED TO PREVENT PUBLIC ACCESS AND ~ SHALL BE PIPED TO DISCHARGE OUTSIDE THE J BUILDING. — — — — — — — — — — — I 16s I I L- - - - - - - - - - - �� I 1 14. FIRE SPRINKLERS SHALL NOT BE REQUIRED UNDER CANOPIES, STAIRS, AND ROSTRUM UNLESS REQUIRED BY THE FIRE MARSHAL. 15. THE SPRINKLER PIPING SUPPLYING THE MAIN LEVEL SPRINKLERS BELOW THE EQUIPMENT PLATFORMS SHALL BE LOCATED WITHIN THE EQUIPMENT PLATFORM FLOOR FRAMING. THE PIPING SHALL BE INSTALLED DOWN ADJACENT TO THE WALL AND SHALL NOT BE ALLOWED TO BE INSTALLED DOWN THROUGH THE CENTER OF THE MECHANICAL AREAS OR UPON THE FLOOR SURFACE. PIPING WITHIN FLOOR FRAMING IS SHOWN DASHED. SEE E/FS501. 16. SEE FS501 FOR SPRINKLER LEGEND, DEVICE LEGEND, AND HYDRAULIC INFORMATION DATA PLACARDS. 17. NOT USED. 18. SITE CONTRACTOR AND FIRE PROTECTION CONTRACTORS SHALL COORDINATE FIRE I PROTECTION PIPING. NOTES: 1. SEE FS501 FOR SPRINKLER LEGEND AND HYDRAULIC CALCULATION PLACARDS. Project Number: 50049487510 Plan Series: IPF -SC -10-04 Property Number: 500-4948 Sheet Title: MAIN FLOOR FIRE SPRINKLER PLAN Sheet: FS101 J CO L o LU V V) Q N y^ J o f6 O Y Project Number: 50049487510 Plan Series: IPF -SC -10-04 Property Number: 500-4948 Sheet Title: MAIN FLOOR FIRE SPRINKLER PLAN Sheet: FS101