Loading...
HomeMy WebLinkAbout75NOT USED SCALE: NONE OOR LINE BALANCE OF PIPING SAME AS CLEANOUT CAST IRON CAP AND SLEEVE BRASS CLEANOUT PLUG W/ (WATER VALVE COVER) COUNTER SUNK HEAD. BRASS CLEANOUT PLUG W/ COUNTER SUNK HEAD. CONCRETE _ FINISH GRADE. III -III -III =111=111=111=1 111 1117 TO GRADE. � 1/8" BEND. FLOOR CLEANOUT (FCO) WASTE LINE. QBALANCE OF PIPING LENGTH TO SUIT. SAME AS CLEANOUT CLEANOUT NOT TO BE LOCATED IN TO GRADE. CARPETED AREA. WASTE LINE 1/8" BEND IF CLEANOUT OCCURS AT END OF LINE. CLEANOUT TO GRADE (COTG) (CONCRETE & GRADE CLEANOUT DETAILS NOTE: DO NOT RUN CONDENSATE DRAIN IN FRONT OF FURNACE AND FILTERS. THIS WILL ALLOW ACCESS TO FURNACE COMPONENTS AND FILTERS. OPEN TO jj ATMOSPHI RUN DRAT TO N EARE FLOOR DR CONDENS/ RECEIVER, CONDENSA DRAIN DR( I SUALE: NONE TO DR, SLOPE 1/4"/F COOLING COIL _ CABINET (TYPICAL) i COOLING COIL CONNECTIONS FURNACE (TYPICAL) Z CONDENSATE DRAIN -ONDENSATE DRAIN TRAP, SEE DETAIL J/P501 )RIP PAN r0 DRIP PAN VERTICAL FURNACE DETAIL SCALE: NONE VACUUM BREAKER OPEN TO ATMOSPHERE /-RUN BELOW TRUSSES CEILING 2" SUPPLY TO BUILDING CEILING ESCUTCHEON 2"BALL VALVE (TYP) P PRESSURE GAGE 0 - 100 PSI RANGE COMBINATION PRESSURE REDUCING VALVE AND STRAINER SET DISCHARGE 0 60 PSIG 3/4" —'—UNION (TYPICAL) HOSE THREAD FITTING 2" DOUBLE CHECK VALVE 2" BY-PASS BACKFLOW PREVENTER WITH BALL VALVES AND STRAINER 2"BALL VALVE (TYP) FLOOR — SLEEVED PENETRATION & 2" WATER SUPPLY FROM MAIN e. d VERTICAL WATER PRESSURE REDUCING STATION DETAIL I SCALE: NONE HOT WATER OUT BALL VALVE (TYPICAL) 2" MINIMUM SIDE CLEARANCE TEMPERATURE PRESSURE RELIEF VALVE — BOTTOM OF HEATER TO BE 3'-0" ABOVE FLOOR LINE RUN DISCHARGE TO FLOOR DRAIN (SAME SIZE --_*0" AS VALVE DISCHARGE) DX COOLING MANUFACTURED 'EZTRAP' IS ACCEPTABLE. COOLING COIL CONDENSATE DRAIN DETAIL SCALE: NONE "TRAP GUARD" INSTALL AS PER MANUFACTURERS INSTALLATION INSTRUCTIONS. PROVIDE PART NUMBER TO MATCH FLOOR DRAIN MANUFACTURER. TRAP GUARD AS MANUFACTURED BY PROSET SYSTEMS INC. ALTERNATE - SURE SEAL NO HUB FITTING BEAD OF SILICON R DRAIN MAY EXTEND AS A WASTE OR VENT LINE. CHROME — WALLCOVER AND SCREW SET TRAP GUARD AGAINST NO HUB RUBBER SLEEVE INDENTATION AT JOINT 2" WASTE PIPE TRAP GUARD TRAP SEAL DETAIL Z)UALL: NUNS FLUE AND ROOF TERMINATION PER MANUFACTURERS RECOMMENDATIONS 3/8" HIGH TEMPERATURE SILICONE REBBER TUBING 3„ RUN TO NEAREST DRAIN 1 1/2" GAS LINE �&ICOLD WATER IN WH -1 GAS COCK GAS REGULATOR VALVE PROVIDED T 1► G WITH UNIT AVERAGE SNOW DEPTH OF 4SHING DOUBLE ROOF PENETRATION ROOF UNION STRAINER AND FLASHING BLOW -DOWN AVERAGE SNOW (TYPICAL)Ull BALL VALVE DEPTH 11 SERVICE VALVE I 1 (TYPICAL) I I —FLOOR LINE SINGLE ROOF PENETRATION TANKLESSGAS WATER HEATER DET ��. AIL �vnLL. IV VIVO STRUT CHANNE� PIPE CLAMP 6" LON SCHEDULE 40 PVC PIPE SLEEVE PIPE INSULATIO BEYOND CALCIUM I O I SILICATE INSERT PIPE RIGID CALCIUM SILICA 10OPSI COMPRESSIVE STRENGTH. TOP AND BOTTOM HALVES GLUED WITH INDUSTRIAL CONTACT CEMENT. OR COMPARATIVE RIGID INSULATION TOP AND BOTTOM OILEVATION ANCHOR BOL 3/4" BALANCING VALVE B & G CIRCUIT SI LOCKABLE SETT HOT AND COLD TEMPERATURE C TRERICE 3 1/2" W/ 112" NO 5- 1/8" IMMERSION RANGE 30•F TO 1..X1 TEE .I WALL PIPE SUPPORT DETAII JI,ALE: NONE 3/4" T FONT If BOTTOM OF BOX 3'-8" ABOVE FLO( Z Id" t-ni n 1A1 d rrr� w U z A ARGO CONSULTING ENGINEERS, INC. 618 N. DAVIDSON STREET INDIANAPOLIS, IN. 46202 PHONE: (317) 639-9244 Q FAX: (317) 639-9249 W W EMAIL: argo®argoce.com 11 cOcopyrigh} 2012 AS. ConsuPdng Engineers, Inc. WALL F- Z �. PLUGGED TEE W ( Q �+ J 0w 7 F" W W PVC DWV PIPE Q = FLOOR LINE V Q 9501 E. 861h St Indianapolis IN (317) 849-6992 faX (317) 849-6993 •,.; 103 Wind Haven Nlcholsvllle KY 1(859)523-1500 fax(859)523-1514 Stamp: ``WAtIIIi iiIl11 IS D ��/ WALL CLEANOUT DETAIL �PR�.".'TE ,�9',"'' 'G S F,Q ,, `mss SCALE: NONE t No % o 19524 ` o -° STATE OF Q W z Q �0 z r=� o J Q �_ � Q J W z� 0 w aLu LO W z � H 0 z JZ ujL) GAS LINE CONNECTION DETAIL SCALE: NONE L rUN VALVE BOX DETAIL SCALE: NONE SleerrTfitle: PLUMBING DETAILS (STANDARD) �P501