HomeMy WebLinkAbout772
t 3
4
C
o I "�, ARGO CONSULTING ENGINEERS, INC.
7 _ 618 N. DAVIDSON STREET
- � - - - H - CU - CU - - - - - - CU CU -- - ��° �' - - - - - - - - - - � INDUWAPOUS. IN. 46202
" ♦ 24X18 RA DUCT ,�c,. ^-�� u HT1 r"I, I, I, V 1 I "I,\�
I 24 HIGH RETURN �u lu/1 u I I,VI T-1 tiCr
137 M : DROP IN CHASE zs,l 7a I,zs,l 7b I,zs,1 u u u u u ,�;-
_ J _ _s I 10 PHONE: (317) 639-9244
AIR PLENUM J __J O z= z=S 11 ' zis"S' '
1000 • • 1 39
�8a
CU------ -- FAX: (317) 639-9249
16X22 RA UP I ''�' I•' 38 18X36 RA g EMAIL• argo0argoce.com
_ -- _ _ • • r _' • • , • • • `1 It l `I — _ _ — — — CU — — — — I — — _ — — — c0 copyright 2012 Argo Consulting Fsginsera, Inc.
EH ' --- --- - 13 -
------ ---------------------------------------------- SEE SHEET M102 FOR OTE:
:ZF--6XT� IRA !}' Ri� I UNITS REQUIRE 3'-0" ------ ---- EE LARGE SCALE
' '—' ---1 , 1 I I I I
--------�-- ----+- -- -- + -- - '--- ----- R-7 CLEARANCE ALL CONTINUATION. LANG M401
11 11 i1 11 1 , 1 , 1 1 11 1 11 1 11 I , I I
I
R-7 AROUND (TYP.) I
I
136 8X 41 Sa 1 141 A �. ; ' X12 SA 145
1§x, 10 6 I 14X12 S ' D
r LIN 5 5 ; 36X6 ; M302 17o D-4
5"�---"-s- 36X6 SA 1 146 ;' D-3 ' " 400 171
�- ; D-6 18X14 SA I I 12 ,
7
I800 (4) 15'10 ; ------ -------------------------- - ---- -------------------- J ----- ---- ----- la I 275 „
(2)r-----, r--, r--, r--, r- , r--, r--, r--, r --T ----, i R-8 !C'4 ` • i i '
r---------------r-----rti---r-r--�-r---rte-- r- --x r--�- -- -r-- ------1---- -� 1
—; / � ,' I I I I I I I I I I I I �12 X1 O I RA I I�UC I I I I ; 975 � 975 �� I `. 18X16 RA ``. � �
< , I 1 1 I I I I I I I I I (�I; I I I I IX _ R-2
L��/ r----- , I I L--r--� I I I I 1 Ip 00, IN THAS L_r_—JJ I '� '' 22X5 UNLINED RA '
i 1 i i i i i I I I
I r- r- I I I I
(2)14X8 RA DUCT DROP IN WALL. 22X5 UNLINED RA
1 II I I I II I , , I 11 I I I I 11 I I , I 1 I I •••• •••••••••••
I 1� I 1 �____ 1� � � I I � � � � � � � � � � � � � � � � I � � � � 1 � � ■ ; I ; DUCT DROP FOR R-2
14X12 SA DUCT UNDER14X 2 143 14" 0 I 10X8 RA _ 10X8 172 IN WALL. '
IRA ABOVE. COORDINA WIT I I '' • D-2
STRUCTURE ,I i i Q —
i1 'JJ i i i i i i i i i i i i i i i it ■
1
IR-2(?)D—b 125
(2) X 10"0
R-1
RG0 Q
Fl -40 8 : .•••.•••.•••••0
I 134 1 3 I I 1 R-3 ii II FIG D-3 ❑❑
.r x
SA DUCT 142 I
I , UP - SEE M102 a N R-3 14X5 U INED RA
I I; I g I 19 I L---� I I I I I � � � � � � � � � � � � � � � � I , ; ; I I I I, 14 1v , M302 275 D-2
1, L—J L_J I I 11 I I I .` 200 (S/D DUCT D OP DUCT
12, << 4 \\ i r 10' r-� 101 RA DUCT DROP FROM FURNACE ABOVE I I I i� 'I a (S/p) 2 DROP I WALL.
\ I I MA CH SIZE OF f URNACE OPENING THEN ,, II A-7151
L_J I 1 I I 1 TRANSITION TO 2 X10 RA. , , (2)14 I ,� I o .. .�.
X8 RA
L... . ... . ......
III IV
L__ ---J L_ _- L _J n- IJ L_ -J L__J L --J L__1 ---__J I I I I , II I I N 168 ❑❑
\ \\\ D-6 () 15 0 I 36X6 SA i ii i i I. ®2 D-1
-- --- --------------------------
...... .........
5"o
800 18X14 SA -------- --------- ----------------_$ ----- I , '' R-9 II � 0 50 R-2
\-----, ' ' I I II r
,r _
-,--J i i 5 i 5 i 5' i 6' QX10 I i i i _ �: ��_ _- " 22X5 UNLINED RA
11 136X6 22X12 166 10 p_3 DUCT DROP FOR R-2
II I
118 14 $'A� ^ 1 14 �- � 14X12 SA SA I' IN WALL.
1 35 i i 1 I �` 12"� 14X6 169 275
' R-7 18X14 SA 24X18 RA DUCT O 167
---- r---I—'I---a--I--------LJi-- — -- �'— — '--- -- -- I 1 o
--r--- r---- II 2 FOR
1 DROP IN CHAS ,SEE SHEET M10 R J 144 8"0
______________ ;CONTINUATION.
.. .........
- - - - : IIwIIIwIII■IIIwIII ------------------------
- 148
I- a J , - ! , -, TI - - _ _ - _ _ - -
36X34 RA ` JI ± - - 3 - - - - - - - - -
`- - 1 SERVICE
132 ' 14X 22X10 141 < II --
-0
RA 2 O 13 C EARANCE REQ'p.
16X22 RA UP I I o '
1 1 X M301 R-3 (S/D) Q D-3 A VE UNIT
' N 29
DIVIDED RETURN AIR PLENUM. • • 0 (S WATER HATER BY
14X10 OTHERS. )ORDINATE 4
SEE DETAIL F/M502. r= —_ ._______________________________- _ ��j �, I cb - - 8"0 } - - - - - - „ - - - - - - - - - - - - - - - - -
i,,r-_ _
I 8"� OA DROP WITH DAMPERS IIII' -_= I I ' 2 D_2 8 D 2 C x 10"� WITH PLU ING
r=---�-----�- =- H ge
2 (S�) 2 A S D 20X14 R ao
200 O® 2 0 (/) M302 1 a R-1 147 CONTRACT R.
Irr____ ___________ PLAN NOTES:
SEE DETAIL E/M502. M301 J o w ,
,III „ ,
111' 1111 pp y�y•...
N <
0 0 .....••••.......
N R-2( ) D_3 R � _ 14X5 UNLINED RA DUCTI )INSTALL RELIEF GRILLE IN CEILING TO
R-3 S
M30 300 _ 153 DROP FOR R-1 (TYP.) PREVENT FREEZING OF PIPING IN ATTIC. SEE
M301 I 12X8 130
o 10"�
1 EF � DETAIL D A303.
D-3 _ _ D-2 E
I x 1 X5 FOR EA H R-1 AND 22 5 FOR EACH
D75 (S%D)� X 225 10 15o a 149 ••200 M302 2 PROVIDE 24"x12" CEILING ACCESS PANEL
11 NLINED RA U T DROP IN AALL. (TYPICAL) 1 0 0 0 1 � , (/ )
10X6 2 _ _ J FOR EACH SMOKE DAMPER ASSEMBLY S D
_EAO e �� X - CEILING DIFFUSERS, RETURN GRIILLES ALL
III IN CENTRAL CORRIDOR. 22X5 UNLINED RA DUC
1 ❑ I „1111 L_ -- ---- _J 1 N Xg R-2 DROP FOR R-2 (TYP.) ACCESS PANELS WITH ARCHITECTS
10X1 EA1-4. 9EFF R-2 REFLECTED CEILING PLAN.
F SEE L RGE SCALE 1 51 o >K O 12"x12" TRANSFER GRILLE UP INTO THE
01:?7
D-1 PLA /M401 FOR D_30"12"0 D-4 SPACE ABOVE.
.c ' 8 0 50 FAN UNIT F-1340
D}1 128 ....................... 25) ' 154 1
NOTE: CU CU CU CU II;,, ,,, ^ft-
� N
., ......
LEAVE SUFFICIENT 8b N 7d 7c III:: 50 ;'--------'D-2 O D 1 C00 DI ATE DUCTS WI FOLDING O 14X5 UNLINED RA DUCT
SPACE BEHIND FAN rti�T1 rGG1 rti�r1 r�G1 ;; 1"' axo ROP FOR R-1 Y
EF I ( )
100 8"� D (TYP
L.1�_lJ I I, I ,,IL I I, I I ''
UNITS FOR DRAIN I T /I Iu�UI IUT�jI IUTIjI ,jill • •••••••••••.. : •••••• ••••••
LINES. COORDINATE �zYs �z=s �zYs �zYs = ; D-2 126 8 O D-3 — — — — 9 2 8"0 155 . • „
WITH PLUMBING -- � D-2 D-2 pH 16 SERVICE
SEE M10 FOR A DH I 200 CLEARANCE REQ'.
CONTRACTOR. 100 CONTIN ATION wI I- EF X 225 I M301 0 1 SEE M401 o I 100 12
8 ABOVE UNIT
o N I- - 4 - - - - - - - - - - - - -
R_2 11 6 X J 2 1 6 1 �a SEE SHEET o '
O• T-1 6 0 R-3 (SA 111 124 M102 FOR D-2 S/D D-2
E A � CONTINUATION 150 AAAAAA
TH 14X8 A D-3
M301 D-3 � EF _ � R_2 D-3 D-2 120 D_1 164 GENERAL NOTES:
300 B ANCH DUCT
• T-1 1 EF I 330 250 200 R_1 50 M302 1. DO NOT USE DUCT LINER IN RETURN AIR
12 8 . ' DUCT RISERS IN 2X6 WALLS SEE DETAIL
f D 18X12 RA 10 0 O 2 -3 0 p_3 1O 8 D_3 : 14X12 SA
SEE LARGE M301 S 109 ` 1 56 1)"�
I 18X12 SA (/D) •••• • ••••••• ••••••••••••••. EF 330 330 8"91 EA 250 A2"O 12 1 B/S521) AND ALL OUTSIDE AIR DUCTS.
SCALE PLAN D-3 1 os 20 20 % UP "
C M401 Q B = 3 rr o •••. ..•., COORDINATE DUCT RISERS IN STUD WALLS
/ ; 325 R 2 D-2 .c, nR2 SA 10 R-2 • • • • • • • • N WITH ELECTRICAL CONTRACTOR.
--------------------- i a N : 117 M30 1 0 O -- 8X8 16X10 S I • / , 1
F - '� N o F 1 " 20X14 RA N----- --------------------
-- x : c° : l o : • • 1 12 A 1 1 3 X 12X12 EF 2. WRAP ALL OUTSIDE AIR DUCTS WITH
C N ao ; o N --- - - ,� 12X6 0 5 SA 1 (4)
------
------ --- .... ._. _
M301 F .X �_ --- � 1, � I � ao � � � ilt� x � � 12X10 `� • ` )x( _ Xl ' �� • � `_' � , , 8 � � 12 2 � 'i 400 EXTERNAL INSULATION.
• h8 1 I I ,I S ®• ,. 1 X12 SA :e., R-1 165
. 3 RE CLEAR
... ..... —
• ' • -
x ALL DUCT DIMENSIONS SHOWN A
22X8 8X8 EA • • • • 1, 1
"' ••• 112 0 •• ' ...... .: �� .= ... :: 1 DIMENSIONS INSIDE DUCT LINER.
--------- -------------------------
R 4 12o IIII X 14X24 SA 11 9 i ; 8X12 SA 2 ' :<� 24X1 1 1 �; _ 158 '� ; , , •�
20X14; SA 4. SEE ARCHITECTURAL REFLECTED CEILING
°�° ---_--- z:z_ 14X10 RA F 2T� 12 R =,� I �,� 12X12 RA I:r_''I I' F I I , 30X14 RA DUCT
--_ ____ _ ---- 8 0 20X12 RAI 12X10 RA I n
=__= 2 S-2 -_�;; 2 11 ' 1 DROP IN CHASE PLAN FOR EXACT LOCATION OF GRILLES AND
665
I I
----------- -- -
EH
2 D 1 18X18 SA I1 118
24X14 RA rr o
M301 24X14 RA ;; 14 X
,I
RUN REFRIGERAI
T 1 D-5 '
�
PIPING THRU FURRED LINED TRANSITION 575
CEILING SPACE AND 32X10 PLENUM
PROVIDED FOR FIRE -2
SPRINKLER PIP114G IN o
_THIS AREA_
0
R-4
1
1
X14 LINED RA ;uyl u I VI
DROP IN CHASE
C ZCU
3 4
A B E C
M301
' 24X12 SA i i I -* i 24X12 SA 1 i i i 12X12 SAor I 106 I
101 0;a. 11 10X8 2 ; 10 Co
I
10"o � �I ..... j1 RA � .i X D
2 I R_2 I II C14D-2 (S/D) R-2 1 2
2 N10„ 0
_ ,I I
I
D-3 (S/p) 8 �� I
I
300 I 104 D-4 ---
D-2 �L-------il j r-- --- -- i -- --- — — D-3 == 3 =_ — —
I 1111 D-4 375 330 'lir----- D-2 = -
R-1 150 103 ''" D-3 105 �'�� 185
1111 X111
350 300 00
I 102 iiii I O iili 125 126
EE RG
E N : 114R_ (S/p) SEE LARGE
115 g/M401 I R-2 SCALE PLAN
rN�T NCT, D/M401 123 (;5 E'-)
I I,J ILllI 14.IGU I I ,,ILL I 1
100 I� /I I\ T /I I IUT`jl Iu,T �%i I
=SJ Z=S LZ=SJ LZ=SJ
CU CU A 14X5 FOR EACH R-1 CU CU
AND 22X5 FOR EACH
2 1 M301 R-2 UNLINED RA 5 12 '
DUCT DROP IN WALL.
D (TYPICAL)
E F
L E G E N D
SYMBOL DESCRIPTION SYMBOL DESCRIPTION SYMBOL DESCRIPTION
BRANCH DUCT TAKE -OFF SEE BDD - (BACK DRAFT DAMPER) SA SUPPLY AIR
DETAIL A/M501
RA RETURN AIR
t
MANUAL VOLUME DAMPER OA OUTSIDE AIR
SINGLE THICKNESS TURNING
VANES FLEX. CONNECTION 6'-0" MAX TA TRANSFER AIR
LENGTH - SEE DETAIL E/M502
FA FRESH AIR (ERV LABEL)
DUCT TRANSITION
DUCT SMOKE DETECTOR. INSTALL 12x12 EA EXHAUST AIR
ACCESS DOOR AT ALL LOCATIONS
AF ABOVE FLOOR
MOTORIZED DAMPER SL UP SLOPE UP OR DN
MAIN FLOOR
1/80' = 1'-0"
O 159 1OX10 RA 22X5 DIFFUSERS.
11 RA
8X12 SA 5. FOR CONTINUATION OF ERV'S EA DISCHARGE
tJ (S/D) ,---------------------------------AND OA INTAKE DUCTS SEE M102.
R-1 6. SEE SHEET M401 FOR LARGE SCALE
R 1 R-2 0 12"� 12"o MECHANICAL ROOM PLANS AND M300
14X12 SA SHEETS FOR MECHANICAL SECTIONS.
■ ,
Fl -61] : D-3 � ■ 230
______________' =__ ■ 7. ALL DUCTWORK SHALL BE INSTALLED WITH
255 0 ■ 163 BOTTOM OF SHEET METAL 8" ABOVE FINISH
CEILING LINE TO ALLOW FOR PLUMBING AND
FIRE SPRINKLER PIPING AND LIGHTS AND
_ _ _ _ CONDUIT.
F 8. SEE DETAILS D/M503 AND E/M503 FOR
M302 1 REFRIGERANT PIPING SUPPORT. ALL
WITH REFRIGERANT COVERPIPING SHALL BE PROTECTED
22X8 LINED RA
DUCT DROP IN 9. MECHANICAL AND FIRE PROTECTION
CHASE BEHIND 1 CONTRACTORS SHALL COORDINATE FIRE
CABINET. PROTECTION PIPING.
G H J
ANICAL
W
W I-_
F_z
Lm Q (D
� W
V
0Q
'0900
W
V) Q =
9501 E. 86th St. Indianapolis IN
(317) 849-6992 fax (317) 849-6993
103 Wind Haven Nicholsville KY
(859)523-1500 fax(859)523-1514
Stamp: `J%►iu11
1111
X`
I..�A/
No. �•�
19524 i o
STATE OF
%/ �,n••, •/A' fit/ �
V I P,,�P�
aW
Z
V)
J
Q
Z)
I---1
O
z
rr=n
V
Ql�
I�
Z
�Q
r^
V /H
I' --q
6
Z
J
O
UJ
W
a
w
m
Qt
z
J
o
^
_Q
1.cc�
�
G
zw
LU
.a
~
V
V)
Project Number:
50049487510
Plan Series:
IPF -SC -10-04
Property Number:
500-4948
Sheet Title:
MAIN FLOOR
MECHANICAL
PLAN
Sheet:
M101
J
I-
m
o
�
LU
.a
~
V
U-)
o
N
}
J
f6
0
Y
Project Number:
50049487510
Plan Series:
IPF -SC -10-04
Property Number:
500-4948
Sheet Title:
MAIN FLOOR
MECHANICAL
PLAN
Sheet:
M101