Loading...
HomeMy WebLinkAbout82CHANNE SPAN 4 TRUSSES SWIVEL ATTACH HANGER \ NOTE: I \ \\ L=1/4 W (4" MINIMUM.) MAIN AIR I\\ L DUCT I /,` -- oe REGULATOR VOLUME DAMPER PROVIDE WHERE SHOWN ON DRAWINGS. 45' I // / AIR BRANCH / �;' / �i %' DUCT (TYPICAL) // �' J NOTE: DAMPERS SHOULD NOT BE INSTALLED CLOSER REMOTE CEILING THAN TWO DUCT WIDTHS OPERATOR TO ELBOWS OR WHERE DAMPER INTERSECTIONS. IS INACCESIBLE SUPPLY OR RETURN AIR DUCT rA'NBRANCH CONNECTION DETAIL SCALE: NONE TOM CHORD OF TRUSS GYPSUM BOARD 1/4"X2 1/4" LAG SCREW WITH WASHER I 1 5/8" CHANNEL UPPER ATTACHMENT DETAIL SCALE: NONE EXTERNAL FILTER SECTION DETAIL SCALE: NONE DO NOT BLOCK FILTER ACCESS WITH CONDUIT, THREADED ROD, OR CONDENSATE DRAINS, RIGID ROUND DUCT OR DIFFUSER COLLAR FAN UNIT (1) TRANSVERSE REINFORCING SIZE IS DETERMINED BY DIMENSION OF SIDE TO WHICH ANGLE IS APPLIED. (2) LONGITUDINAL JOINTS TO BE PITTSBURG OR SNAP LOCK TYPE. n DUCT CONSTRUCTION DETAIL SCALE: NONE AIR FLOW C 24 GA, LOCKING QUADRANT HANDLE ON THE SIDE OR REMOTE CEILING OPERATOR ON THE BOTTOM WHERE DAMPER IS INACCESSIBLE NYLON CLAMP OVER INSULATION NYLON CLAMP OVER FLEX DUCT ?AYYYYY INSULATION 1 SECTION 1/8" THICK NEOPRENE GASKET HINGE FULL HEIGHT OF DOOR DP d FLEX. DUCT 12"O.0 FASTE (TYPIC 12"O.C.MAX. IN DIRECTION F AIR FLOW. F DUCT IS FABRICATED N AUTOMATED COIL LINE SIS DIMENSION MAY BE (CREASED TO 14" MAX.) DUCT LINER ARGO CONSULTING ENGINEERS, INC. 618 N. DAVIDSON STREET INDIANAPOLIS, IN. 46202 PHONE: (317) 639-9244 FAX: (317) 639-9249 EMAIL: argo®argoce.com (E)copyright 2012 Argo Consulking Engineers, Inc. C•I IrC'T .I CTAI rll 1/' r NOTE: ALL TRANSVERSE AND LONGITUDINAL EDGES OF LINER TO BE COATED WITH ADHESIVE. NOT MORE THAN 2" FROM EDGE OF LINER. n DUCT LINER _DET AIL 45° TAP AND DAMPER ASSEMBLY IS PRE MANUFACTURED - SEE SPECIFICATIONS FOR APPROVED MANUFACTURERS. DO NOT FABRICATE IN SHOP OR FIELD. RIGID ROUND DUCT SEE PLANS FOR LENGTH. WRAP WITH EXTERNAL INSULATION. INSULATED FLEX DUCT. MAX LENGTH 6'-0" LONG RADIUS BEND WITH NO KINKS OR BUCKLES LIIYLV VII 1 ��_R PLENUM BOX WHEN LONG RADIUS BEND IS NOT POSSIBLE NOTE: TAKE -OFFS SHOULD NOT BE INSTALLED CLOSER THAN TWO WIDTHS TO ELBOWS OR INTERSECTIONS NOTE: AREA OF A X B SHALL BE EQUAL TO 1.5 X AREA BRANCH DUCT SQUARE TO ROUND TAKE—OFF DETAIL SCALE: NONE R ATTACHMENT L F/M501 E MP 1/2" PER SUPPORT FLEXIBLE DUCT SUPPORT DETAIL SCALE: NONE SEE SECTION 1 RIGID ELBOW SEE SECTION 1 SCALE: NONE 2" DOUBLE SHEET METAL STRAP BACK OVER. BOTTOM CHORD OF TRUSS 5/8" GYPSUM BOARD INSULATION —� o 1 " X 18 GAGE STRAP HANGERS AT 8'-0" SPACING. (1) #10 X 2" WOOD SCREWS @ EACH TRUSS CHORD (TYP.) #10 X 3/4" SELF TAPPING GALVANIZED SHEET METAL SCREWS TO ANCHOR STRAPS TO DUCT. ALL STRAPS TO BE TIGHT AGAINST DUCT AND SUPPORT MEMBERS. (TYPICAL) NO POP RIVETS ALLOWED 1 1/4" MIN. PENETRATION DUCT STRAP HANGER DETAIL J SCALE: NONE CEILING DIFFUSER w z —I DOOR TRANSVERSE REINFORCING (1) u M UPPER ATTACHMENT (TYP.) AT JOINTS Z U 01 Q FLEX CONNECTION MINIMUM Y m Q Q' J w o QCQ�o P--4 TYPICAL OF 4 00 a W (D z REINFORCING = wwcnmv� z )� NOTE: 00 ~ w¢ 0 0 DIMENSION SHEET ANGLE SIZE o 0 0 0 � w PATHS CLEARANCE IN FRONT Q g F METALLONGEST GAGE AND MAXIMUM LONGITUDINAL W F- Q ly-0 ��>� DRIVE - H H SIDE, (ALL SPACING a 0 o= U w Q o DAMPER IN MAIN EA Cr Q � � F- 0 INCHES FOUR BETWEEN MIN. SLIP AS REQUIRED. _� _41 DUCT CONNECTIONcr SIDES) SIDES) TRANSVERSE H. ARRANGEMENT REIN - JOINTS &/OR IN. RA FROM HEMMED ALTER'NT FORCED Z 0zomawowe 0 N INTERMEDIATE DUCT PLAIN S SLIP BAR SLIP BAR SLIP N MAIN RETURN S SLIP AIR DUCT FLOOR REINFORCING TYPICAL ERV CONNECTION DETAIL } RECOM- RECOM- RECOM- RECOM- SCALE: NONE MENDED MENDED MENDED MENDED J GAGE GAGE GAGE GAGE UP THRU 12 26 NONE REQUIRED 1 26 26 24 24 13 - 18 24 NONE REQUIRED 1 24 24 24 24 19 - 30 24 1 "X1 "X1 /8" @ 60 IN 1 - 1 24 1 24 1 24 31 - 36 1 22 1 "X1 "X1 8" @ 60 IN 1 - - 22 22�] (1) TRANSVERSE REINFORCING SIZE IS DETERMINED BY DIMENSION OF SIDE TO WHICH ANGLE IS APPLIED. (2) LONGITUDINAL JOINTS TO BE PITTSBURG OR SNAP LOCK TYPE. n DUCT CONSTRUCTION DETAIL SCALE: NONE AIR FLOW C 24 GA, LOCKING QUADRANT HANDLE ON THE SIDE OR REMOTE CEILING OPERATOR ON THE BOTTOM WHERE DAMPER IS INACCESSIBLE NYLON CLAMP OVER INSULATION NYLON CLAMP OVER FLEX DUCT ?AYYYYY INSULATION 1 SECTION 1/8" THICK NEOPRENE GASKET HINGE FULL HEIGHT OF DOOR DP d FLEX. DUCT 12"O.0 FASTE (TYPIC 12"O.C.MAX. IN DIRECTION F AIR FLOW. F DUCT IS FABRICATED N AUTOMATED COIL LINE SIS DIMENSION MAY BE (CREASED TO 14" MAX.) DUCT LINER ARGO CONSULTING ENGINEERS, INC. 618 N. DAVIDSON STREET INDIANAPOLIS, IN. 46202 PHONE: (317) 639-9244 FAX: (317) 639-9249 EMAIL: argo®argoce.com (E)copyright 2012 Argo Consulking Engineers, Inc. C•I IrC'T .I CTAI rll 1/' r NOTE: ALL TRANSVERSE AND LONGITUDINAL EDGES OF LINER TO BE COATED WITH ADHESIVE. NOT MORE THAN 2" FROM EDGE OF LINER. n DUCT LINER _DET AIL 45° TAP AND DAMPER ASSEMBLY IS PRE MANUFACTURED - SEE SPECIFICATIONS FOR APPROVED MANUFACTURERS. DO NOT FABRICATE IN SHOP OR FIELD. RIGID ROUND DUCT SEE PLANS FOR LENGTH. WRAP WITH EXTERNAL INSULATION. INSULATED FLEX DUCT. MAX LENGTH 6'-0" LONG RADIUS BEND WITH NO KINKS OR BUCKLES LIIYLV VII 1 ��_R PLENUM BOX WHEN LONG RADIUS BEND IS NOT POSSIBLE NOTE: TAKE -OFFS SHOULD NOT BE INSTALLED CLOSER THAN TWO WIDTHS TO ELBOWS OR INTERSECTIONS NOTE: AREA OF A X B SHALL BE EQUAL TO 1.5 X AREA BRANCH DUCT SQUARE TO ROUND TAKE—OFF DETAIL SCALE: NONE R ATTACHMENT L F/M501 E MP 1/2" PER SUPPORT FLEXIBLE DUCT SUPPORT DETAIL SCALE: NONE SEE SECTION 1 RIGID ELBOW SEE SECTION 1 SCALE: NONE 2" DOUBLE SHEET METAL STRAP BACK OVER. BOTTOM CHORD OF TRUSS 5/8" GYPSUM BOARD INSULATION —� o 1 " X 18 GAGE STRAP HANGERS AT 8'-0" SPACING. (1) #10 X 2" WOOD SCREWS @ EACH TRUSS CHORD (TYP.) #10 X 3/4" SELF TAPPING GALVANIZED SHEET METAL SCREWS TO ANCHOR STRAPS TO DUCT. ALL STRAPS TO BE TIGHT AGAINST DUCT AND SUPPORT MEMBERS. (TYPICAL) NO POP RIVETS ALLOWED 1 1/4" MIN. PENETRATION DUCT STRAP HANGER DETAIL J SCALE: NONE CEILING DIFFUSER 6X6 INSPECTION w z —I DOOR SEE DETAIL D/M501 FOR -Q u M UPPER ATTACHMENT (TYP.) w U� w< o p U W Cn Z U 01 Q FLEX CONNECTION VIBRATION ISOLATOR Y m Q Q' J w o QCQ�o P--4 TYPICAL OF 4 00 a W (D z L`Cn = wwcnmv� z )� NOTE: 00 ~ w¢ 0 0 0 36" MINIMUM SERVICE LOCATE BALANCING DAMPERS o 0 0 0 � w PATHS CLEARANCE IN FRONT Q g w OF ALL ERV's. F U Li W F- Q ly-0 o- - w� D Q w ALSO SEE DETAILS AT PROVIDE BACKDRAFT o a 0 o= U w Q o DAMPER IN MAIN EA Cr Q � � F- 0 w DUCT. TRANSITION DUCT a o U 0 z DO NOT FOLLOW THIS AS REQUIRED. = w Lr - DUCT CONNECTIONcr U U0 of w Q =)w�f— tYZ ARRANGEMENT o-2o�oLd \ RA FROM RETURN AIR Z 0zomawowe 0 N DUCT AIR DUCT 6X6 INSPECTION Y) Q WH 1 z rte^ �f UJ (� 0 v J 0� v f (� W Q = V tzQ 9501 E. 861h St Indianapolis IN (317) 849-6992 fax (317) 849-6993 103 Wind Haven Nlcholsville KY (859)523-1500 fax(859)523-1514 Stamp-,A'C 1 S11�A o,����/i \STER� s i N o. =o: 19524 :o= STATE OF �, F DIA Q W —I DOOR SEE DETAIL D/M501 FOR u M UPPER ATTACHMENT (TYP.) �0 FLEX CONNECTION VIBRATION ISOLATOR O P--4 TYPICAL OF 4 JQ a W (D z HANGER ROD W z )� Q AIR FLOW LOCATE BALANCING DAMPERS PATHS NEAR ERV DISCHARGE OUTLETS Q J AS SHOWN AV NOTE: - z ALSO SEE DETAILS AT Q 0 ERV SCHEDULE M601 z<cc FOR ERV UNITS THAT 2- DO NOT FOLLOW THIS j 0 DUCT CONNECTIONcr U 6X6 INSPECTION ARRANGEMENT DOOR FA TO MAIN RA FROM RETURN AIR MAIN RETURN 0 N DUCT AIR DUCT N MAIN RETURN AIR DUCT FLOOR TYPICAL ERV CONNECTION DETAIL } J SCALE: NONE Y) Q WH 1 z rte^ �f UJ (� 0 v J 0� v f (� W Q = V tzQ 9501 E. 861h St Indianapolis IN (317) 849-6992 fax (317) 849-6993 103 Wind Haven Nlcholsville KY (859)523-1500 fax(859)523-1514 Stamp-,A'C 1 S11�A o,����/i \STER� s i N o. =o: 19524 :o= STATE OF �, F DIA Q W z� Q M �0 z rV n O P--4 Z JQ (D z J 0 W z )� Q U I'D Q J ,� I--4 z W Project Number: 50049487510 Plan Series: IPF -SC -10-04 Property Number: 500-4948 Sheet Title: MECHANICAL DETAILS Sheet: MI 501 I J m � o UJ 2- U 0 N N N } J D � I I I I I I I C' Project Number: 50049487510 Plan Series: IPF -SC -10-04 Property Number: 500-4948 Sheet Title: MECHANICAL DETAILS Sheet: MI 501 I