HomeMy WebLinkAbout832 Jtl� IIUIV AnTTnn� - OF ROOF TRUSS MINIMUM 6 FT. LONG, 1 5/8" CHANNEL (UNISTRUT P1000) TO SPAN THREE (3) TRUSSES (TYP. OF 2) FASTEN UNISTRUT CHANNEL TO BOTTOM OF THREE (3) TRUSSES SEE DETAIL D/M501. EADED HANGER Vv v RODS DOWN TO EQUIPMENT AS REQUIRED. (TYPICAL) UPPER SUPPORT DETAIL SCALE: NONE EXHAUST Q 12" M ABOVE AVERP SNOW ACCUN FLASHI ROOF BOTTOM CHORD OF ROOF TRUSS SEE DETAIL D/M501. SWIVEL TYPE ATTACHMENT TO CHANNEL (UNISTRUT #M2137). TYPICAL AT ALL HANGER RODS. 1 5/8" CHANNEL (UNISTRUT P1000) OPENING RETURN / TO FAN l FOR 2, SI FOR SIZE. CONCENTRIC ROOF TERMINATION DETAIL SCALE: NONE 20 GA. GALV. SLEEVE. ALLOW PIPING TO MOVE FREELY THRU—SLEEVE 2X2 BLOCKING AS REQUIRED FASTEN TO STRUCTURE SCREW (TYPICAL). 20 GA. GALV. SHEET METAL STRAP I—JOIST NSION KIT 2Y TO ACHEIVE :E ABOVE SNOW 20" 20" CHAPEL RETURN AIR PLENUM SCALE: NONE PARTITION TO SEPARATE RETURN AIR FLOWS FROM EACH FAN UNIT OPENING FOR R-5 )TES: 1— LINE INTERIOR OF PLENUM WITH ACCOUSTICAL DUCT LINER. 2— DIMENSIONS SHOWN ARE ACTUAL SHEET METAL. (THIS PLENUM ONLY). r/ -\IN UINI I r—b INSTALL 20 GAUGE SHEET METAL RETAINER CLIP WHERE FRAMING FOR OPENING DOES NOT ALLOW FOR SCREWS TO ATTACH TO FRAMING MEMBER PERPENDICULAR TO FACE OF FRAME GRILLE FRAME INSTALL ATTACHMENT SCREWS PERPENDICULAR TO FACE OF FRAME SCREW INTO FRAMING WHERE OPENING IS CORRECTLY SIZED ;AL FAN UNIT NAL FILTER SECTIONS. SEE DETAILS )2 AND G/M501 FOR CONSTRUCTION 'HE FAN UNIT SCHEDULE SHEET FOR FILTER SIZE. )E 1/8%1%1" GALVANI ZED ANGLE n STAND TO SUPPORT EQUIPMENT AND II DE LINED MIXED AIR PLENUM BELOW II NIT . 8" HIGH MINIMUM. II u11"u 1VIM1114 .�ur-rI_I AIR AND MAIN RETURN AIR DUCT. SEE PLAN FOR SIZE. � I ---------- ----� OVERSIZED FRAMED OPENING OPENING FRAMED TO MATCH GRILLE SIZE GRILLE ATTACHMENT DETAIL SCALE: NONE LINED SHEET METAL ALL AROUND AND AT BOTTOM. SEE SPECIFICATION. II U FLOOR FLEXIBLE CONNECTION — ALL FAN UNITS EXCEP THE F-6 AND F -7's FAN UNIT SUPPORT DETAILS SCALE: NONE HINGED (FULL WIDTH) DOOR WITH HINGE ON r TOP AND LATCHES ON BOTTOM AS SHOWN. MOUNTED ON SHT. METAL. SEE DETAIL G/M501 FOR ,NCE GASKET REQUIREMENTS. J UNIT ACK E K 1/8"xlxl SQ. TUBING' FRAME AT EACH CORNER, 2—SIDES AND THE BACK COMBINATION FILTER AND SUPPORT FRAME SCALE: NONE VERTICAL FAN UNIT EXTERNAL FILTER SECTIONS. SEE DETAIL G/M501 AND FAN UNIT EQUIPMENT SCHEDULE FOR FILTER SI ZE., SEE DETAIL G/M502 DETAIL OF STAND TO SUPPORT EQUIPMENT (BOTH FAN UNITS) AND PROVIDE LINED MIXED AIR PLENUM BELOW FOR THIS FAN UNIT 20 HIGH MINIMUM. FLOOR LINED MAIN RETURN AIR DUCT. SEE I PLAN FOR SIZE. I I I I I �—------- ARGO CONSULTING ENGINEERS, INC. 618 N. DAVIDSON STREET INDIANAPOLIS, IN. 46202 PHONE: (317) 639-9244 FAX: (317) 639-9249 EMAIL: argo0argoce.com (Dcopyrighi. 2012 Argo Consulting Enginsars, Inc. EXTERNAL FILTER SECTIONS. SEE DETAIL G/M501 AND FAN UNIT EQUIPMENT SCHEDULE FOR FILTER SIZE. SEE ALSO G/M502 FOR BOTTOM FILTERS. 7 milial NffiNdwo e!��-� ----------------- --- 177 FLEXIBLE CONNECTION LINED MIXED LINED MAIN RETURN AIR AIR PLENUM DUCT. SEE PLAN FOR SIZE. Ed 13/16"x13/32", 19 GAGE CHANNEL. FLOOR L� I FULL WIDTH OF PLENUM. TYPICAL 1" WIDE x 3/4" TALL x FULL LENGTH OF CHANNEL, NEOPRENE VIBRATION WAFFLE PAD. MOTORIZED OA DAMPER. (2—POSITION—OPEN/CLO' OA FROM LOUVER MANUAL OA DAMPER. BALANCE PER OUTSIDE AIR LISTED IN FAN UNIT SCHEDULE ON SHEET M601. TO MAIN RA DUCT TYPICAL OUTSIDE AIR DUCT DETAIL SCALE: NONE SEE DETAIL ON SHEET ME201 MIN, 12X12 DUCT ACCESS DOOR TO SERVICE SMOKE DAMPER. LINED SHEET METAL DUCT ::/ FLEX SUPPLY BREAK—AWAY 16 GA. STEEL SLEEVE DUCT CONNECTION ACTUATOR SMOKE DAMPER W/ ACTUATOR ON MECH. EQUIP. ACCESS OUTSIDE OF DUCT. DAMPER ACTIVATED FLOOR SHEATHING. BY CORRIDOR SMOKE DETECTOR. NOTE: F WOOD JOIST INSTALL ACCORDING TO MANUFACTURERS RECOMMENDATIONS CEILING CONSTRUCTION CEILING DIFFUSER OR GRILLE u SMOKE DAMPER DETAIL SCALE: NONE (SIDEWALL REGISTERS SIMILAR) NOTE: PROVIDE 24" x 12" CEILING ACCESS DOOR FOR ACCESSIBILITY FOR SMOKE DAMPER V1 � Q Ww Z W �_--�U� 0w F- V W Q = V Q 9501 E. 86th St. Indianapolis IN (317) 849-6992 fax (317) 849-6993 103 Wind Haven Nicholsvllle KY (859)523-1500 fax(859)523-1514 Stamp: `o11111111w� D,q,��,,�,� •G\STe ,f N o. i o : 19524 : o STATE DIA OF r �• ►11111 Q UJ Z � Q I --I Q Z (nV O +Y 1--� Z V) �Q z J W ( Z f -I cc)w J � Ime Q < LU 1410 LU ❑ G Z W F— H Project Number: 50049487510 Plan Series: IPF -SC -10-04 Property Number: 500-4948 Sheet Title: MECHANICAL DETAILS M502 J CO � o LU � v H ami cn p N � o r fo CD Y a Project Number: 50049487510 Plan Series: IPF -SC -10-04 Property Number: 500-4948 Sheet Title: MECHANICAL DETAILS M502