HomeMy WebLinkAbout87EQUIPMENT PLATFORM MECHANICAL PLAN
NORTH
O O
F
I I
c LJ `J L
3 - -
I
I
0
I „
MAIN FLOOR PLAN
1/16" = 1'-0"
NORTH
r-1
LJ
r-1
LJ
G O
I I
1
I i
- - - 2
ARGO CONSULTING ENGINEERS, INC.
618 N. DAVIDSON STREET
INDIANAPOLIS, IN. 46202
PHONE: (317) 639-9244
FAX: (317) 639-9249
EMAIL: argo®argoce.com
(E)copyright 2012 Argo Consulting Engineers, Inc.
NOTE:
ALL TEMPERATURE CONTROL CONDUIT SHALL
BE FURNISHED AND INSTALLED BY DIVISION 26.
SYMBOLS
O & T2 THERMOSTAT/SUBBASE OUTLET (DIV 23). PROVIDE J—BOX
MOUNT TOP OF THERMOSTAT 5'-6" ABOVE FLOOR.
RP-6DH RELAY PANEL (DIV 23) MOUNT 5'-0" TO BOTTOM OF CABINET
REMOTE SENSOR OUTLET (DIV 26) COORDINATE LOCATION WITH CHALK BOAR[
WS WEBSTAT (DIV 23) MOUNT TO TELEPHONE BOARD
H❑ HUMIDITY SENSOR COORDINATE LOCATION WITH CHALK BOARD
NOTES:
1. BOXES FOR REMOTE SENSOR OUTLETS SHALL BE 2"X4"
WITH LONG DIMENSION VERTICAL.
2. BOXES FOR WEBSTAT (WS) AND THERMOSTAT OUTLETS SHALL BE 4"X4".
3. J—BOXES IN MECHANICAL AREAS SHALL BE 4"X4".
4. CONDUIT TO BE 1/2" UNLESS NOTED OTHERWISE.
5. FOR AVERAGING SENSORS USE 3/4" CONDUIT.
6. TEMPERATURE CONTROL WIRING THAT IS NOT IN CONDUIT SHALL BE
RUN PARALLEL AND PERPENDICULAR TO BUILDING CONSTRUCTION LINES.
SEE SPECIFICATIONS FOR ACCEPTABLE FASTENING METHODS AND
MAXIMUM ALLOWABLE SPACING BETWEEN FASTENERS.
7. TEMPERATURE CONTROL WIRING THAT IS NOT IN CONDUIT SHALL
BE LABELED. PROVIDE A LABEL AT ALL POINTS WHERE TEMPERATURE
CONTROL WIRING ENTERS CONDUIT AND AT CONNECTIONS TO DEVICES.
SEE SPECIFICATIONS FOR LABEL TYPE AND SIZE.
8. INSTALL COMMUNICATION E—BUS CABLE 12 INCHES MINIMUM AWAY
FROM OTHER LOW VOLTAGE AND LINE VOLTAGE WIRING.
9. REFER TO FAN UNIT SCHEDULE FOR HIGH HEAT WIRING FOR
UNITS F-1 AND F-2.
Q
UJ �
z
w
(� 0
J
O Q
w
:3
V
W
F -
Q =
V
Q
9501 E. 861h St Indianapolis IN
(317) 849-6992 fax (317) 849-6993
103 Wind Haven Nicholsvllle KY
(859)523-1500 fax(859)523-1514
Stamp: ��%%wU1nUqr
S, D,q I c
No.
= i
=o: 19524 �o=
STATE OF
Q
W
W�
z�
�
a�
�0
xj
0
Z
COO
�D
O
'—'
Z
J Z
lessesse,
cs z
J
0w
z
LU
CO
Z
LU
iZ
U
lesessell�
o�
zw
iesseeii
Project Number:
50049487510
Plan Series:
IPF -SC -10-04
Property Number:
500-4948
Sheet Title:
AUTOMATIC
TEMPERATURE
CONTROL
FLOOR PLANS
ME1 01
E--�
W�
�
w
O
o V
xj
0
L-
CL V
w
COO
�D
Ew.,
E-+
Wo
Project Number:
50049487510
Plan Series:
IPF -SC -10-04
Property Number:
500-4948
Sheet Title:
AUTOMATIC
TEMPERATURE
CONTROL
FLOOR PLANS
ME1 01
J
CO
U
o
w
.n
�
v
V
v
V)
o
N
�
J
�
D
v
C
o
0
Y
(O
Project Number:
50049487510
Plan Series:
IPF -SC -10-04
Property Number:
500-4948
Sheet Title:
AUTOMATIC
TEMPERATURE
CONTROL
FLOOR PLANS
ME1 01