Loading...
HomeMy WebLinkAbout87EQUIPMENT PLATFORM MECHANICAL PLAN NORTH O O F I I c LJ `J L 3 - - I I 0 I „ MAIN FLOOR PLAN 1/16" = 1'-0" NORTH r-1 LJ r-1 LJ G O I I 1 I i - - - 2 ARGO CONSULTING ENGINEERS, INC. 618 N. DAVIDSON STREET INDIANAPOLIS, IN. 46202 PHONE: (317) 639-9244 FAX: (317) 639-9249 EMAIL: argo®argoce.com (E)copyright 2012 Argo Consulting Engineers, Inc. NOTE: ALL TEMPERATURE CONTROL CONDUIT SHALL BE FURNISHED AND INSTALLED BY DIVISION 26. SYMBOLS O & T2 THERMOSTAT/SUBBASE OUTLET (DIV 23). PROVIDE J—BOX MOUNT TOP OF THERMOSTAT 5'-6" ABOVE FLOOR. RP-6DH RELAY PANEL (DIV 23) MOUNT 5'-0" TO BOTTOM OF CABINET REMOTE SENSOR OUTLET (DIV 26) COORDINATE LOCATION WITH CHALK BOAR[ WS WEBSTAT (DIV 23) MOUNT TO TELEPHONE BOARD H❑ HUMIDITY SENSOR COORDINATE LOCATION WITH CHALK BOARD NOTES: 1. BOXES FOR REMOTE SENSOR OUTLETS SHALL BE 2"X4" WITH LONG DIMENSION VERTICAL. 2. BOXES FOR WEBSTAT (WS) AND THERMOSTAT OUTLETS SHALL BE 4"X4". 3. J—BOXES IN MECHANICAL AREAS SHALL BE 4"X4". 4. CONDUIT TO BE 1/2" UNLESS NOTED OTHERWISE. 5. FOR AVERAGING SENSORS USE 3/4" CONDUIT. 6. TEMPERATURE CONTROL WIRING THAT IS NOT IN CONDUIT SHALL BE RUN PARALLEL AND PERPENDICULAR TO BUILDING CONSTRUCTION LINES. SEE SPECIFICATIONS FOR ACCEPTABLE FASTENING METHODS AND MAXIMUM ALLOWABLE SPACING BETWEEN FASTENERS. 7. TEMPERATURE CONTROL WIRING THAT IS NOT IN CONDUIT SHALL BE LABELED. PROVIDE A LABEL AT ALL POINTS WHERE TEMPERATURE CONTROL WIRING ENTERS CONDUIT AND AT CONNECTIONS TO DEVICES. SEE SPECIFICATIONS FOR LABEL TYPE AND SIZE. 8. INSTALL COMMUNICATION E—BUS CABLE 12 INCHES MINIMUM AWAY FROM OTHER LOW VOLTAGE AND LINE VOLTAGE WIRING. 9. REFER TO FAN UNIT SCHEDULE FOR HIGH HEAT WIRING FOR UNITS F-1 AND F-2. Q UJ � z w (� 0 J O Q w :3 V W F - Q = V Q 9501 E. 861h St Indianapolis IN (317) 849-6992 fax (317) 849-6993 103 Wind Haven Nicholsvllle KY (859)523-1500 fax(859)523-1514 Stamp: ��%%wU1nUqr S, D,q I c No. = i =o: 19524 �o= STATE OF Q W W� z� � a� �0 xj 0 Z COO �D O '—' Z J Z lessesse, cs z J 0w z LU CO Z LU iZ U lesessell� o� zw iesseeii Project Number: 50049487510 Plan Series: IPF -SC -10-04 Property Number: 500-4948 Sheet Title: AUTOMATIC TEMPERATURE CONTROL FLOOR PLANS ME1 01 E--� W� � w O o V xj 0 L- CL V w COO �D Ew., E-+ Wo Project Number: 50049487510 Plan Series: IPF -SC -10-04 Property Number: 500-4948 Sheet Title: AUTOMATIC TEMPERATURE CONTROL FLOOR PLANS ME1 01 J CO U o w .n � v V v V) o N � J � D v C o 0 Y (O Project Number: 50049487510 Plan Series: IPF -SC -10-04 Property Number: 500-4948 Sheet Title: AUTOMATIC TEMPERATURE CONTROL FLOOR PLANS ME1 01