Loading...
HomeMy WebLinkAbout99120 VAC FIRE ALARM PANEL VESTIBULE 100 FIRE DETECTION SYMBOLS (� SMOKE DETECTOR O1 HEAT DETECTOR FRCP I FIRE ALARM CONTROL PANEL F❑ MANUAL STATION H< HORN/STROBE WITH 15cd STROBE (HIGHER OUTPUT STROBES AS NOTED 1--I ON DRAWINGS) 9< WEATHERPROOF HORN/STROBE WITH WP 15cd STROBE (HIGHER OUTPUT STROBES 126 106 AS NOTED ON DRAWINGS) EOL END OF LINE WIRING DEVICE OD DUCT SMOKE DETECTOR (BY DIV 23) ® 15cd STROBE ONLY FS WATER FLOW SWITCH FT—sl VALVE TAMPER SWITCH VTJ LOW TEMPERATURE SENSOR WP DEVICE DESIGNED FOR OUTDOOR USE PIV POST INDICATOR VALVE (COORDINATE ` LOCATION WITH FIRE SPRINKLER CONTRACTOR) SD SMOKE DAMPER SD SD F-13 CITE 9 SD F-11 OTE 9 SD `- OTE 9 SD S F-5 OTE 9 F-2 OTE 9 SD F-1 -NOTE 9 UPPER MECHANICAL IF -7a F -7b F -8a F -7c F -7d F -8b 11 11 11 11 137 1® iEC I ? D 2 D 2 D D D D PIV TS TS FS LT LT LT NOTE 7 100 1 0 1 1 1® 1 1 131 121 1®14 1® 168 16 159 14 149 1® 1® 1® INITIATING LOOP OUTSIDE II 4,U T140 ' CU JURAL CNTR Q 110 1--I O 100 101 104 106 105 126 106 160 163 165 164 159 157 156 155 d cD d Z ag ` W o Q = U z 110cd WP is Q J 110cd LU n a� OU TSIDE Z w U 147 149 170 172 168 168 Fl -67-1 110cd ANNUNCIATION LOOP EOL 11Ocd J � ABOVE ABOVE ABOVE ABOVE OUTSIDE1®1® 119 117 116 1 7 1 8 121 131 FE179 OUTSIDE 14 P45 rl4 44 ri4 o � EOL ANNUNCIATION NOTE 8 110cd Y 110cd 110cd 110cd 110cd 110cd 11Ocd i �o 08 � 111 111 111 Fl -24-1 124 14 151 14 COURTYARD 14 Z! LEOL ANNUNCIATION 110cd WP NOTE 8 OFF—SITE NOTIFICATION SYSTEM 1/2" C AND TWO (2) TELEPHONE CABLES TO TELEPHONE TERMINAL BOARD FIRE ALARM RISER DIAGRAM NOT TO SCALE NOTES: 1. WIRING FROM DIFFERENT ANNUNCIATION AND INITIATING DEVICES LOOPS MAY BE COMBINED IN A COMMON CONDUIT. FOLLOW NEC REQUIREMENTS FOR FILL. 2. COORDINATE FIRE ALARM DEVICES WITH LIGHTING FIXTURES, SPEAKERS, GRILLS, ETC. 3. DO NOT INSTALL SMOKE DETECTORS WITHIN 3' OF ANY MECHANICAL GRILL. 4. NON—POWER LIMITED AND POWER LIMITED WIRING SHALL BE SEPARATED IN FACP. 5. PERMANENTLY IDENTIFY LOCATION OF CIRCUIT BREAKER FEEDING FACP AND PROVIDE RED MARKING ON CIRCUIT BREAKER. 6. PROVIDE PROTECTIVE WIRE GUARD ON DEVICES NOTED. 7, SEE A/FS501 FOR LOCATIONS OF DEVICES. 8. PROVIDE CONNECTION FOR FIRE SPRINKLER SYSTEM EXTERNAL BELL/HORN STROBE. SEE E/FS501. 9. PROVIDE CONTROL RELAY TO INTERRUPT POWER TO SMOKE DAMPER FROM FIRE ALARM. 2 L VI I TVI" -I SCALE: 1/16" =1'-0" MED 137 2 �- MEC 120 A1WIFIE2I:4 WMAW, MA T_LSC1 ALE. 1 /16 —1 0 NORTH ARGO CONSULTING ENGINEERS, INC, 618 N. DAVIDSON STREET INDIANAPOLIS, IN. 46202 PHONE: (317) 639-9244 FAX: (317) 639-9249 EMAIL: argo®argoce.com Q copyright 2012 Argo Con-Itng Engir—, Inc. Yl � Q W w Z Q � W 0 %= U _J O Vj F- U VJ W F- U Q 9501 E. 861h St. Indianapolis IN (317)849-6992 fax(317)849-6993 103 Wind Haven Nicholsvllle KY (859)523-1500 fax(859)523-1514 Stamp:P�GiSc9,``' S No. � = o : 19524- STATE 9524STATE OF 00 .. /L1 IrIiIMIM Q II 4,U T140 ' CU JURAL CNTR Q 110 T_LSC1 ALE. 1 /16 —1 0 NORTH ARGO CONSULTING ENGINEERS, INC, 618 N. DAVIDSON STREET INDIANAPOLIS, IN. 46202 PHONE: (317) 639-9244 FAX: (317) 639-9249 EMAIL: argo®argoce.com Q copyright 2012 Argo Con-Itng Engir—, Inc. Yl � Q W w Z Q � W 0 %= U _J O Vj F- U VJ W F- U Q 9501 E. 861h St. Indianapolis IN (317)849-6992 fax(317)849-6993 103 Wind Haven Nicholsvllle KY (859)523-1500 fax(859)523-1514 Stamp:P�GiSc9,``' S No. � = o : 19524- STATE 9524STATE OF 00 .. /L1 IrIiIMIM Q W z J Q M 1--I O Z O l0-111 Z _Q �— cD Z Z ag O W o Q = U z UJ is Q J LU n a� Z w U Project Number: 50049487510 Plan Series: IPF -SC -10-04 Property Number: 500-4948 Sheet Title: FIRE ALARM PLAN FA1 01 J m � D o V) LU n U J � o � Y i �o Project Number: 50049487510 Plan Series: IPF -SC -10-04 Property Number: 500-4948 Sheet Title: FIRE ALARM PLAN FA1 01