HomeMy WebLinkAboutE11.0GENERAL NOTES: A. TRACK HEADS SHOWN DO NOT DEPICT EXACT QUANTITY/LAYOUT DESIRED. RWSC FIELD PERSONNEL TO COORDINATE EXACT TRACK HEAD PLACEMENT. B. SHOWROOM UGHTING LOCATIONS SHALL TAKE PRECEDENCE OVER LOCATION OF SPIRAL DUCTWORK. MECHANICAL AND ELECTRICAL CONTRACTORS SHALL COORDINATE 1 INSTALL CRAFTMADE CEILING FAN TO BE CONTROLLED VIA CRAFTMADE DIMMER (4—WIRE CONNECTION REQUIRED). CEILING FAN AND DIMMER PROVIDED BY RWSC. COORDINATE INSTALLATION WITH LIGHT FIXTURES AND OCCUPANCY SENSORS. SEE ALSO 4/A9.1 OPROVIDE AND INSTALL OCCUPANCY SENSOR SWITCH FOR CONTROL OF STOCKROOM LIGHTING. OPROVIDE UGHT FIXTURE ON NIGHT LIGHT CIRCUIT FOR NIGHT UGHTING PURPOSES. 4 INSTALL EMERGENCY LIGHTS PROVIDED BY RWSC & PROVIDE & INSTALL EXIT UGHTS REQUIRED TO COMPLY WITH LOCAL CODE. OPROVIDE SWITCH BANK AT 48" AFF FOR CONTROL OF SALES LIGHTING. SEE SWITCHING SCHEDULE FOR CONTROLS. ONOT USED. OPROVIDE J—BOX AND DISCONNECTING MEANS IN CEILING SPACE FOR CONNECTION OF SIGN POWER. VERIFY REQUIREMENTS AND FIELD VERIFY LOCATIONS AND EXISTING CONDITIONS. FINAL CONNECTION OF SIGN BY SIGN VENDOR. CIRCUIT VIA TIME CLOCK OPROVIDE UNSWITCHED BRANCH CIRCUIT TO EMERGENCY BATTERY TYPES 'RFI' & 'F', AND EXIT SIGNS. EMERGENCY LIGHTS TO BE MOUNTED ABOVE FIXTURES. COORDINATE LOCATION WITH FIELD REPRESENTATIVE. OINTEGRAL TRACK CURRENT UNDER AS SHOWN FURNISHED BY LIGHTING VENDOR. UGHTOUER 3.0 AMP CURRENT UNDER INSTALLED AND WIRED BY ELECTRICAL CONTACTOR. 10 LOCATION OF EXISTING ELECTRICAL SERVICE. SEE RISER ON SHEET E3.0.— CONTRACTOR SHALL FIELD VERIFY EXACT LOCATION. 11 NEW TIMECLOCK, SEE RISER ON SHEET E&O. 12 PROVIDE AND INSTALL OCCUPANCY SENSOR SWITCH(WITH MANUAL OVERRIDE) FOR CONTROL OF RESTROOM LIGHTING AND EXHAUST FAN. 13 INSTALL OWNER PROVIDED LED STRIP UNDER SHELF DISPLAY LIGHTS IN DESIGNATED OUTRIGGERS— SEE FLOOR PLAN. SWITCH "e" TO CONTROL. RELEASED FOR CONSTRUCTION Subject to compliance with all regulations of State and Local Codes City of Camel DATE: 06/06/18 o -- D o -- LIGHT FIXTURE SCHEDULE WATTAGE TYPE LAMP FIXTURE DESCRIPTION CATALOG NUMBER VOLTAGE A LEO 12W LED TRACK LIGHTING, MOUNTED AT 10'-0"AFF. PROVIDE LIVE END JUNG: 120 2700 DEG.K FEED WITH CURRENT LIMITING DEVICE AS NOTED AND SHOWN. TRACK — T689 BL USE JUNO T—SERIES TRACK AND COMPONENTS AND INCLUDE ANY LAMP — LED12DP30RB27/40 OTHER ACCESSORIES REQUIRED FOR A COMPLETE INSTALLATION. B LED PENDANT FIXTURE, MOUNTED AT 10'-0" AFF. PROVIDE THREADED PIPE OR HI—LTTE: 120 12W RIGID CONDUIT STEM. FIXTURE — H16RW—SIG22-96—LEADS LAMP — LED10DA19 827 PENDANT FIXTURE, MOUNTED AT 7'-6" AFF. PROVIDE THREADED PIPE OR JUNG: 120 C LED 12W RIGID CONDUR STEM. FIXTURE — VP1501M12 LAMP — LED10DA19 827 8' LED STRIP, MOUNTED AT 11'-0" ARE UTHONLA 120 D ,_,D la IILL��EE// Ta 36W FIXTURE—R-132—MVOLT—GEB101S LAMP—LED18ET8/4/835 4 LED STRIP, MOUNTED AT 11'-0" ARE CREATIVE ILLUMINATION, INC D1 T7) 15W 15W LED—lT2-32—XVL 120 ?4 T4/48-3500 CEILING FAN, MOUNTED AT 10'-0" PER MANUFACTURER'S SPECIFICATIONS. CRAFTMADE: E --- 10OW CEILING FAN PROVIDED BY OWNER WITH 16" DOWN ROD. PROVIDE #VE58FB3 CONDUIT DOWN ROD AS NEEDED. F (2) SAW 12W EMERGENCY EGRESS FIXTURE, ALUMINUM HOUSING, HIGH TEMP 90 MINUTE UTHONIA 120 NI—CAD BATTERY, WEE LOCATION RATED. (CEILING MOUNTED, COLOR BLACK) FIXTURE—ELM2—LED B M12 PAR G LED 6W LED EXIT SIGN, SINGLE FACE THERMOPLASTIC HOUSING, 90 MINUTE LITHONIA 120 NI—CAD BATTERY W/ REMOTE CAPABILITY, SELF DIAGNOSTICS. FIXTURE—ECR—LED HO M6 RH 2 SAW 12W INCANDESCENT EGRESS LAMPHOLDER, 2 HEADS, SEALED AND GASKETED, LITHONIA 120 PAR WIRED FOR EMERGENCY ONLY OPERATION TO EXIT SIGN. FIXTURE—ELA—LED T WPM12 LAMP—INTEGRAL LED J LED 12W WALL MOUNTED SCONCE AT W-6" A.F.F. TO CENTER OF BOX. LITHONIA 120 FIXTURE—V120M12 LAMP—LED10DA19/827 K EXISTING 120 ALL LIGHTING, CEILING FAN, OCCUPANCY SENSORS AND CURRENT LIMITERS AND EMERGENCY BATTERY PACKS PROVIDED BY OWNER'S REPRESENTATIVE: SCOTT MOSEMAN AT GRAYBAR PHONE (612)810-0916, DOTTIE GEDDES AT GRAYBAR PHONE (314)573-5548,REDWINGSHOES®GRAYBAR.COM EXIT LIGHTS/SIGNS ARE PROVIDED BY RED WING SWITCH DIAGRAM 5e e 0 SALES TRACK OPEN DISPLAY SALES PENDANT LIGHTING SIGN LIGHTING FAN NOTE: SWITCH BANK PROVIDE FOUR GANG BOX FOR SWITCHES "a"&"b"&"c"&"e" WITH SEPARATE COVER PLATE. PROVIDE SINGLE GANG BOX FOR FAN CONTROL AND SEPARATE COVER PLATE. COORDINATE WITH "RWS" PROJECT MANAGER. SHEET INDEX E1.0 LIGHTING PLAN E2.0 POWER PLAN E3.0 ELECTRICAL PANELBOARD SCHEDULES, RISER DIAGRAMS AND SYMBOLS E4.0 ELECTRICAL SPECIFICATIONS FIXTURE LABELING KEY /_ INDICATES FIXTURE TYPE R1 L-70�INDICATES SWITCH CONTROL INDICATES CIRCUIT NUMBER NOTE TO BIDDERS/CONTRACTORS: THESE DRAWINGS WERE PREPARED AS ACCURATELY AS POSSIBLE UTILIZING LANDLORD/OWNER/ARCHITECT INFORMATION. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO FIELD VERIFY ALL CONDITIONS PRIOR TO THE BIDDING AND COMMENCEMENT OF THE PROPOSED PROJECT. CLAIMS FOR EXTRAS RESULTING FROM LACK OF COMPLIANCE WILL BE DENIED. N.E.C. NOTE PER 2008 N.E.C. 210.4(8), ALL BRANCH CIRCUITS IN MULTI—WIRE HOMERUNS SHALL BE CONNECTED BY HANDLE—TIES ON THE CIRCUIT BREAKERS TO PROVIDE SIMULTANEOUS DISCONNECT FOR ALL CONDUCTORS. LIGHTING PLAN 1/4" = l' -O" Alan J.Plutowski ARCHITECT 4125 Lakeland Ave. N., Suite 200 Minneapolis, Minnesota 55422 763-533-7171 rax 763-533-7979 Consultants �`-�B�C� RED WING SHOES 31" " SMET M WW. YH 550,W W1o11E (we) 733-„«. FW, (651) a., -m.7 Certification Project Information RED WING SHOES BUILD -OUT FOR NEW DEALER STORE Red Wing Shoe Store 9893 N. Michigan Rd, ate 1204 Carmel, Indiana 46032 Revisions Date: 04/06/18 Drawn By: SMB Checked By: NMM Job Number: 18RW-007 Sheet Information BIEC11RiM LIGMWG PIAN COPYRIGHT 2018 ALAN J. PLUTOWSKI EIW0