HomeMy WebLinkAboutE11.0GENERAL NOTES:
A. TRACK HEADS SHOWN DO NOT DEPICT EXACT QUANTITY/LAYOUT DESIRED. RWSC FIELD
PERSONNEL TO COORDINATE EXACT TRACK HEAD PLACEMENT.
B. SHOWROOM UGHTING LOCATIONS SHALL TAKE PRECEDENCE OVER LOCATION OF SPIRAL
DUCTWORK. MECHANICAL AND ELECTRICAL CONTRACTORS SHALL COORDINATE
1 INSTALL CRAFTMADE CEILING FAN TO BE CONTROLLED VIA CRAFTMADE DIMMER (4—WIRE
CONNECTION REQUIRED). CEILING FAN AND DIMMER PROVIDED BY RWSC. COORDINATE
INSTALLATION WITH LIGHT FIXTURES AND OCCUPANCY SENSORS. SEE ALSO 4/A9.1
OPROVIDE AND INSTALL OCCUPANCY SENSOR SWITCH FOR CONTROL OF STOCKROOM
LIGHTING.
OPROVIDE UGHT FIXTURE ON NIGHT LIGHT CIRCUIT FOR NIGHT UGHTING PURPOSES.
4 INSTALL EMERGENCY LIGHTS PROVIDED BY RWSC & PROVIDE & INSTALL EXIT UGHTS
REQUIRED TO COMPLY WITH LOCAL CODE.
OPROVIDE SWITCH BANK AT 48" AFF FOR CONTROL OF SALES LIGHTING. SEE SWITCHING
SCHEDULE FOR CONTROLS.
ONOT USED.
OPROVIDE J—BOX AND DISCONNECTING MEANS IN CEILING SPACE FOR CONNECTION OF
SIGN POWER. VERIFY REQUIREMENTS AND FIELD VERIFY LOCATIONS AND EXISTING
CONDITIONS. FINAL CONNECTION OF SIGN BY SIGN VENDOR. CIRCUIT VIA TIME CLOCK
OPROVIDE UNSWITCHED BRANCH CIRCUIT TO EMERGENCY BATTERY TYPES 'RFI' & 'F', AND
EXIT SIGNS. EMERGENCY LIGHTS TO BE MOUNTED ABOVE FIXTURES. COORDINATE
LOCATION WITH FIELD REPRESENTATIVE.
OINTEGRAL TRACK CURRENT UNDER AS SHOWN FURNISHED BY LIGHTING VENDOR.
UGHTOUER 3.0 AMP CURRENT UNDER INSTALLED AND WIRED BY ELECTRICAL CONTACTOR.
10 LOCATION OF EXISTING ELECTRICAL SERVICE. SEE RISER ON SHEET E3.0.— CONTRACTOR
SHALL FIELD VERIFY EXACT LOCATION.
11 NEW TIMECLOCK, SEE RISER ON SHEET E&O.
12 PROVIDE AND INSTALL OCCUPANCY SENSOR SWITCH(WITH MANUAL OVERRIDE) FOR
CONTROL OF RESTROOM LIGHTING AND EXHAUST FAN.
13 INSTALL OWNER PROVIDED LED STRIP UNDER SHELF DISPLAY LIGHTS IN DESIGNATED
OUTRIGGERS— SEE FLOOR PLAN. SWITCH "e" TO CONTROL.
RELEASED FOR CONSTRUCTION
Subject to compliance with all regulations
of State and Local Codes
City of Camel
DATE: 06/06/18
o --
D
o --
LIGHT FIXTURE SCHEDULE
WATTAGE
TYPE
LAMP
FIXTURE
DESCRIPTION
CATALOG NUMBER
VOLTAGE
A
LEO
12W
LED TRACK LIGHTING, MOUNTED AT 10'-0"AFF. PROVIDE LIVE END
JUNG:
120
2700 DEG.K
FEED WITH CURRENT LIMITING DEVICE AS NOTED AND SHOWN.
TRACK — T689 BL
USE JUNO T—SERIES TRACK AND COMPONENTS AND INCLUDE ANY
LAMP — LED12DP30RB27/40
OTHER ACCESSORIES REQUIRED FOR A COMPLETE INSTALLATION.
B
LED
PENDANT FIXTURE, MOUNTED AT 10'-0" AFF. PROVIDE THREADED PIPE OR
HI—LTTE:
120
12W
RIGID CONDUIT STEM.
FIXTURE — H16RW—SIG22-96—LEADS
LAMP — LED10DA19 827
PENDANT FIXTURE, MOUNTED AT 7'-6" AFF. PROVIDE THREADED PIPE OR
JUNG:
120
C
LED
12W
RIGID CONDUR STEM.
FIXTURE — VP1501M12
LAMP — LED10DA19 827
8' LED STRIP, MOUNTED AT 11'-0" ARE
UTHONLA
120
D
,_,D la
IILL��EE//
Ta
36W
FIXTURE—R-132—MVOLT—GEB101S
LAMP—LED18ET8/4/835
4 LED STRIP, MOUNTED AT 11'-0" ARE
CREATIVE ILLUMINATION, INC
D1
T7) 15W
15W
LED—lT2-32—XVL
120
?4
T4/48-3500
CEILING FAN, MOUNTED AT 10'-0" PER MANUFACTURER'S SPECIFICATIONS.
CRAFTMADE:
E
---
10OW
CEILING FAN PROVIDED BY OWNER WITH 16" DOWN ROD. PROVIDE
#VE58FB3
CONDUIT DOWN ROD AS NEEDED.
F
(2) SAW
12W
EMERGENCY EGRESS FIXTURE, ALUMINUM HOUSING, HIGH TEMP 90 MINUTE
UTHONIA
120
NI—CAD BATTERY, WEE LOCATION RATED. (CEILING MOUNTED, COLOR BLACK)
FIXTURE—ELM2—LED B M12
PAR
G
LED
6W
LED EXIT SIGN, SINGLE FACE THERMOPLASTIC HOUSING, 90 MINUTE
LITHONIA
120
NI—CAD BATTERY W/ REMOTE CAPABILITY, SELF DIAGNOSTICS.
FIXTURE—ECR—LED HO M6
RH
2 SAW
12W
INCANDESCENT EGRESS LAMPHOLDER, 2 HEADS, SEALED AND GASKETED,
LITHONIA
120
PAR
WIRED FOR EMERGENCY ONLY OPERATION TO EXIT SIGN.
FIXTURE—ELA—LED T WPM12
LAMP—INTEGRAL LED
J
LED
12W
WALL MOUNTED SCONCE AT W-6" A.F.F. TO CENTER OF BOX.
LITHONIA
120
FIXTURE—V120M12
LAMP—LED10DA19/827
K
EXISTING
120
ALL LIGHTING, CEILING FAN, OCCUPANCY SENSORS AND CURRENT LIMITERS AND EMERGENCY BATTERY PACKS PROVIDED BY OWNER'S
REPRESENTATIVE:
SCOTT MOSEMAN AT GRAYBAR PHONE (612)810-0916,
DOTTIE GEDDES AT GRAYBAR PHONE (314)573-5548,REDWINGSHOES®GRAYBAR.COM
EXIT LIGHTS/SIGNS ARE PROVIDED BY RED WING
SWITCH DIAGRAM
5e
e 0
SALES TRACK OPEN DISPLAY SALES
PENDANT LIGHTING SIGN LIGHTING FAN
NOTE:
SWITCH BANK PROVIDE FOUR GANG BOX
FOR SWITCHES "a"&"b"&"c"&"e" WITH
SEPARATE COVER PLATE. PROVIDE
SINGLE GANG BOX FOR FAN CONTROL
AND SEPARATE COVER PLATE.
COORDINATE WITH "RWS" PROJECT
MANAGER.
SHEET INDEX
E1.0 LIGHTING PLAN
E2.0 POWER PLAN
E3.0 ELECTRICAL PANELBOARD SCHEDULES, RISER DIAGRAMS
AND SYMBOLS
E4.0 ELECTRICAL SPECIFICATIONS
FIXTURE LABELING KEY
/_ INDICATES FIXTURE TYPE
R1
L-70�INDICATES SWITCH CONTROL
INDICATES CIRCUIT NUMBER
NOTE TO BIDDERS/CONTRACTORS:
THESE DRAWINGS WERE PREPARED AS ACCURATELY
AS POSSIBLE UTILIZING
LANDLORD/OWNER/ARCHITECT INFORMATION. IT
SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR
TO FIELD VERIFY ALL CONDITIONS PRIOR TO THE
BIDDING AND COMMENCEMENT OF THE PROPOSED
PROJECT. CLAIMS FOR EXTRAS RESULTING FROM
LACK OF COMPLIANCE WILL BE DENIED.
N.E.C. NOTE
PER 2008 N.E.C. 210.4(8), ALL BRANCH CIRCUITS IN
MULTI—WIRE HOMERUNS SHALL BE CONNECTED BY
HANDLE—TIES ON THE CIRCUIT BREAKERS TO
PROVIDE SIMULTANEOUS DISCONNECT FOR ALL
CONDUCTORS.
LIGHTING PLAN
1/4" = l' -O"
Alan J.Plutowski
ARCHITECT
4125 Lakeland Ave. N., Suite 200
Minneapolis, Minnesota 55422
763-533-7171 rax 763-533-7979
Consultants
�`-�B�C�
RED WING SHOES
31" " SMET M WW. YH 550,W
W1o11E (we) 733-„«. FW, (651) a., -m.7
Certification
Project Information
RED WING SHOES
BUILD -OUT FOR
NEW DEALER
STORE
Red Wing Shoe Store
9893 N. Michigan Rd, ate 1204
Carmel, Indiana 46032
Revisions
Date: 04/06/18
Drawn By: SMB
Checked By: NMM
Job Number: 18RW-007
Sheet Information
BIEC11RiM LIGMWG PIAN
COPYRIGHT 2018 ALAN J. PLUTOWSKI