Loading...
HomeMy WebLinkAboutGN0T1.2REu SW RESPONSIBILITY SCHEDULE CATEGORY ITEM EXISTING DEALER RED WING TENANT'S GC LANDLORD NOTES PROVIDE INSTALL PROVIDE INSTALL PROVIDE INSTALL PROVIDE INSTALL DEMOLITION WALLS GLOBAL PROJECT MANAGER STORE DEVELOPMENT TEL: 651-385-1132 314 MAIN STREET FAX: 651-385-0891 RED WING, MN 55066 EMAIL: Jalme.lenczawelUMadwlrgehoeecom NOTE: NA PLUMBING BEN ANDERSON FOR A LIST OF GENERAL STORE CONSTRICTION 4 SERVICES MANAGER TEL: 651-385-6119 CONTRACTORS, PLEASE X X CONTACT THE STORE RED WING, MN 55066 EMAIL: banandersonaredwingshoeeram CONSTRICTION 4 ELECTRICAL SERVICES MANAGER RED WING SHOES SARA LIDDLE NA CONSTRICTION WALLS DEVELOPMENT FAX: 651-385-0891 314 MAIN STREET X X RED WING, MN 55066 DEALER FIN164ES BRICK TEL: 311-691-1002 X EMAIL: Ilogdetm4eaolcam X LYNN MILBURN CONCRETE POLISH EMAIL: hnllbwm3aaoI=nn LANDLORD CASIO X X 250 CIVIC CENTER DRIVE, SUITE 500 TEL: 614-221-3466 COLUMBUS, OH 43215 CONCRETE SEAL EMAIL: Iafenlmoraacastolnfocom LIGHTNG SUPPLIER GRAYBAR X X CELL: 612-810-0916 PAINT TEL: 314-513-5548 X X NORTHERN METAL PRODUCTS NAOMI BIEHL SALES ACCOUNT MANAGER VCT X 6601 RIDGEWOOD ROAD FAX: 320-252-2832 ST. CLOUD, MN 56303 EMAIL: naomlbM thnatcom STOCKROOM SHELVNG SUPPLIER TRANSACTION MARKETING 4 SALES, NO. JEFF DEGEAL ACT EMAIL: Jatfd treneleceaecommrom EXTERIOR SIGN NATIONAL AWING AND SIGN TODD WEFNER PRESIDENT TEL: 811-625-4323 NA FIXTURES SHOWROOM EMAIL: toddaawningandelgncan X X ION CITY OF CARTEL STOCKROOM jest to compl compliance with all regulations COMMUNITY SERVICES - BUILDINGS TEL: 311-511-2489 X ONE CIVIC SQUARE- THIRD FLOOR FAX: 311-511-2499 X CARMEL, IN 46032 EMAIL: nedehleracarmel.ingov City d Camel PLUMBING X X HVAC UNIT X DUCTUJOR . X X X FIN16WES X X ELECTRICAL PANEL X X ROUGH -IN DEVICES X X FURNITURE FURNITURE X X DOORS, FRAMES, DOUBLE-ACTING DOOR X X N HARDWARE RESTROOM X N OTHER X X h LIGHTING SHOWROOM X X STOCKROOM X X RESTROOM X X LOW VOLTAGE 5EGI1R7Y X X n COMPUTER X X wl TELEPHONE X X wl AUDIO/SOUND SYSTEM X X wl PONT OF SALE X X wl FIRE PROTECTION FIRE SPRINKLER SYSTEM X X 3 FIRE ALARM SYSTEM X X 3 FIRE EXTINGUISHERS X X MISC. SOUND PANELS X X SHOWROOM RJG X X WINDOW GRAPHICS X X NOTES: I. SEE NOTES IN DOOR SCHEDULE. 2. ROUCsH-N ONLY - SEE SHEET E20 FOR FULL EXTENT OF WORK 3. EXISTING SYSTEMS TO BE MODIFIED AS REQUIRED BY GCS 5,113 -CONTRACTORS. VENDOR CONTACT INFORMATION CONSTRICTION MANAGEMENT RED WING SHOES MARISA DILLE DIRECTOR OF REAL ESTATE DEVELOPMENT TEL: 651-385-1184 314 MAIN STREET FAX: 651-385-0891 RED WING, MN 55066 EMAIL: marleadlllesradwingeYaae.com RED WING SHOES JAIME LENCZEWSKI GLOBAL PROJECT MANAGER STORE DEVELOPMENT TEL: 651-385-1132 314 MAIN STREET FAX: 651-385-0891 RED WING, MN 55066 EMAIL: Jalme.lenczawelUMadwlrgehoeecom NOTE: RED WING SHOES BEN ANDERSON FOR A LIST OF GENERAL STORE CONSTRICTION 4 SERVICES MANAGER TEL: 651-385-6119 CONTRACTORS, PLEASE 314 MAIN STREET FAX: 651-385-0891 CONTACT THE STORE RED WING, MN 55066 EMAIL: banandersonaredwingshoeeram CONSTRICTION 4 SERVICES MANAGER RED WING SHOES SARA LIDDLE PROJECT COORDINATOR - REAL ESTATE TEL: 651-385-1194 DEVELOPMENT FAX: 651-385-0891 314 MAIN STREET EMAIL: sara.Ilddlearedwingehoee.com RED WING, MN 55066 DEALER MILBURN SHOES, INC. DAVE MILBURN TEL: 311-691-1002 EMAIL: Ilogdetm4eaolcam LYNN MILBURN TEL: 311-401 EMAIL: hnllbwm3aaoI=nn LANDLORD CASIO KELLY FENIMORE, PROPERTY MANAGER 250 CIVIC CENTER DRIVE, SUITE 500 TEL: 614-221-3466 COLUMBUS, OH 43215 FAX: 614-221-3016 EMAIL: Iafenlmoraacastolnfocom LIGHTNG SUPPLIER GRAYBAR SCOTT MOSEMAN CELL: 612-810-0916 DOTTIE GEDDES TEL: 314-513-5548 EMAIL: redwlneshn egraybarcom SALES FIXTURE SUPPLIER NORTHERN METAL PRODUCTS NAOMI BIEHL SALES ACCOUNT MANAGER TEL: 320-258-2362 6601 RIDGEWOOD ROAD FAX: 320-252-2832 ST. CLOUD, MN 56303 EMAIL: naomlbM thnatcom STOCKROOM SHELVNG SUPPLIER TRANSACTION MARKETING 4 SALES, NO. JEFF DEGEAL TEL: 800-636-9888 EMAIL: Jatfd treneleceaecommrom EXTERIOR SIGN NATIONAL AWING AND SIGN TODD WEFNER PRESIDENT TEL: 811-625-4323 ALEDO, TX 16008 FAX: 811-625-2@3 EMAIL: toddaawningandelgncan ASED FOR CONSTRUCTION ION CITY OF CARTEL NICK MISHLER - COMMERCIAL PERMITTING COORDINATOR jest to compl compliance with all regulations COMMUNITY SERVICES - BUILDINGS TEL: 311-511-2489 ONE CIVIC SQUARE- THIRD FLOOR FAX: 311-511-2499 of Siand Local Codes CARMEL, IN 46032 EMAIL: nedehleracarmel.ingov City d Camel yNt���w�WaA� DATE: \ 06/06/18 DIVISION I - GENERAL REQUIREMENTS L THE WORK INCLUDES NEW TENANT IMPROVEMENTS M AN EXISTING SPACE, PER SQUARE FOOT CALCULATIONS AS NOTED ON THE TITLE SHEET. CONTRACT WILL INCLUDE CONSTRUCTING WALLS AND CEILMGS, STANDARD FNISHES, DETAILS AND SPECIFICATIONS. SECURE AND PAY FOR GOVERNMENT FEES, LICENSES, MID PERMITS. 2. CONTRACTORS SHALL VISIT THE PREMISES WHILE BIDDING AND SHALL FAMILIARIZE THEMSELVES WITH EXISTING CONDITIONS AND THE REQUIREMENTS OF THE PROJECT PRIOR TO DEVELOPING THEIR BID. MATERIAL QUANTITIES SHALL BE BASED ON ACTUAL FIELD CONDITIONS AND MEASUREMENTS. DO NOT RELY ON SCALING PLANS FOR ACCURATE DIMENSIONING 3. PRIOR TO BEGINNING THE WORK, VERIFY ALL EXISTING DIMENSIONS AND SQUARE FOOTAGES. NOTIFY THE OWER OF COMPLIANCE OR DISCREPANCIES, COMPARING TH05E DISCREPANCIES TO THE NUMBERS ON THE TITLE SHEET. 4. CONTRACTORS SHALL TAKE CARE TO PROTECT ADJACENT AREAS FROM DUST AND DAMAGE DURING THE CONSTRICTION PROCESS, AND SHALL CLEAN UP AFTER THEMSELVES AT THE END OF EACH WORK DAY. 5. ALL RUBBISH AND TRASH SHALL BE REMOVED FROM THE PREMISES AND PROPERLY DISPOSED OF EACH DAY. NO RUBBISH SHALL BE LEFT IN THE PREMISES AFTER WORK 15 COMPLETED EACH DAY. 6. THE ENTIRE SET OF DRAWINGS LISTED HEREIN CREATE AN ENTIRE PACKAGE. ALL TRADES SHALL BE RESPONSIBLE FOR REVIEWING THEIR RESPECTIVE REQUIREMENTS AND COORDINATING THEIR HIDDEN OR EXPOSED WORK WITH OTHER RELATED TRADES. CONTRACTOR SHALL NOTIFY ARCHITECT OF ANY CONFLICT OR DISCREPANCY IN THE DRAWINGS. 1. COORDINATE ALL WORK OF THE VARIOUS TRADES AND SUBCONTRACTORS TO ASSURE EFFICIENT AND ORDERLY INSTALLATION. PROVIDE ACCOMMODATION FOR ITEMS TO BE INSTALLED AT A LATER DATE. VERIFY THAT CHARACTERISTICS OF ELEMENTS OF INTERRELATED OPERATING EQUIPMENT ARE COMPATIBLE. COORDINATE WORK OF VAROUS SECTIONS WHICH HAVE INTERDEPENDENT RESPONSIBILITIES FOR INSTALLING, CONNECTING TO, AND PLACING IN SERVICE, SUCH EQUIPMENT. COORDINATE SPACE REQUIREMENTS AND INSTALLATION OF MECHANICAL AND ELECTRICAL WORD AND FIRE SPRINKLER SYSTEM (U4 -ERE IT OCCURS) WHICH ARE INDICATED, DETAILED OR IMPLIED DIAGRAMMATICALLY ON DRAWINGS. S. LNLE58 SPECIFICALLY NOTED, PROVIDE AND PAY FOR LABOR MATERIALS AND EQUIPMENT, TOOLS, CONSTRUCTION EQUIPMENT AND MACHINERY AND OTHER FACILITIES MID SERVICES NECESSARY FOR PROPER EXECUTION AND COMPLETION OF WORK, INCLUDING PERMITS. UTILITIES SHALL BE PROVIDED BY OWNER WITH CONNECTIONS BY THE CONTRACTOR- S ONTRACTOR9 GENERAL CONTRACTOR SHALL PURCHASE AND MAINTAIN INSURANCE COVERAGE IN ACCORDANCE WITH THE FEQUIREMENTS OF THE LANDLORD AND THE TENANT. VERIFY AND COORDINATE WITH THE TENANT'S PROJECT MANAGER ANY ADDITIONAL REQUIREMENTS. 10. FURNISH ALL REQUIRED TEMPORARY FACILITIES AND ALL TEMPORARY UTILITIES IMMEDIATELY AFTER RECEIPT OF NOTICE TO PROCEED FOR USE OF ALL THOSE ENGAGED IN THE PROJECT WORC It. ALL CONTRACTORS MUST STAY BEHIND THE BARRIERS AND MANTAIN ACCESS TO SUCH AREAS CLEAN AND FREE OF CONSTRICTION MATERIALS AND DEBRIS. FAILURE TO MAINTAIN CLEAN STOREFRONT WILL RESULT IN BUILDING MANAGEMENT HAVING SUCH MATERIALS AND DEBRIS REMOVED AND ALL CHARGES, 12. COORDINATE ALL CONSTRUCTION 4 SCHEDULING WITH THE BUILDING MANAGER REVIEWING ALL SCHEDULED ACTIVITIES AT OUTSET OF CONSTRUCTION. 13. ALLOWABLE TOLERANCES - UNLESS OTHERWISE NOTED OR INDICATED. THE FOLLOWING TOLERANCES SHALL APPLY TO ALL WORD a. ALL VERTICAL SURFACES SHALL BE PLUMB OR CONSTRUCTED TO THE EXACT SLOPES OR ANGLES INDICATED. b. THE MAXIMUM DEVIATION FROM THE TRUE PLANE FOR VERTICAL AND HORIZONTAL SURFACES SHALL NOT BE GREATER THAN 1/8" IN 10'-011 AS MEABIJRED BY A STRAIGHT EDGE PLACED ANYWHERE ON THE SURFACE. in. ALL HORIZONTAL SURFACES SHALL BE LEVEL OR CONSTRUCTED TO THE EXACT ANGLE INDICATED OR INTENDED. d. WALL AND SOFFIT INTERSECTIONS SHALL BE 90. OR THE EXACT ANGLE INDICATED OR NTENDED. a ALL CORNERS AND EDGES SHALL BE STRAIGHT AND TRUE WITHOUT DENTS, WAVES, OR BULGES OR OTHER BLEMISHES. F. ALL JOINTS SHALL BE TIGHT, STRAIGHT, EVEN AID SMOOTH. g. ALL OPERABLE ITEMS SHALL OPERATE SMOOTHLY WITHOUT STICKING OR BINDING AND WITHOUT EXCESSIVE "PLAY" OR LOOSENESS. 14. THE FOLLOWING FINISH MATERIALS SHALL BE LEFT AT THE JOBSITE. THEY SHALL BE TAKEN FROM THE SAME MATERIAL, LOT OR " USED TO CONSTRUCT AND FINISH THE PROJECT: a. SIX YARDS OF CARPET. (IF FLOOR 15 CARPETEDJ b. FOUR FULL LENGTH STRIPS OF RUBBER OR VINYL BASE. a FOUR FULL CEILING TILES OF EACH TYPE. (IF CEILING 15 TILED.) d. I QUART OF EACH COLOR PAINT IN A TIGHTLY SEALED AND MARKED CAN. MATERIALS SHALL BE LEFT IN ONE LOCATION UPON O UNER'S REPRESENTATIVE'S DIRECTION AND APPROVAL. SEE CLOSE-OUT DOCUMENTS FOR ADDITIONAL MATERIALS AND REQUIREMENTS. B. THE OWER OR THE OWNER'S SJBCQNTRACTORS MAY OCCUPY PORTIONS OF THE PROJECT DURING THE FINAL STAGE OF OONSTIRUCTION COORDINATE AND COOPERATE WITH THE OWNER TO MINIMIZE CONFLICT AND FACILITATE THE OUNER'S SET-UP OPERATION 16. ALL DIMENSIONS AND FINISHES SHALL BE VERIFIED MID COORDINATED WITH EXISTING CONDITIONS PRIOR TO CONSTRUCTION, FABRICATION, OR PURCHASING. IN CASE OF CONFLICT BETWEEN THE PROJECT REQUIREMENTS AND/OR EXISTING CONDITIONS. THE ONE HAVING THE MOST STRINGENT REQUIREMENTS SHALL GOVERN, AS APPROVED BY THE OWER IT PERFORM ALL WORK IN ACCORDANCE WITH ACCEPTABLE TRADE PRACTICE TO INSURE THE HIGHEST QUALITY FINISHED PRODUCT - EXPRESSED OR IMPLIED. PERFORM ALL WORK BY SKILLED MECHANICS IN ACCORDANCE WITH ESTABLISHED STANDARDS OF WORKMANSHIP IN EACH OF THE VARIOUS TRADES. ALL MECHANICAL , ELECTRICAL, PLUMBING AND LOW -VOLTAGE WORK. SHALL BE CRAFTED TO A HIGH LEVEL OF AESTHETICS IUNERE WORK IS TO BE EXPOSED. 18. COORDINATE BLOCKING REQUIREMENTS WITH ADJACENT OR RELATED TRADES, ACCESSORIES, EQUIPMENT 4 FIXTURES. INSTALL REQUIRED BLOCKING AT NO ADDITIONAL COST TO THE CONTRACT. VERIFY AND INSTALL BLOCKING FOR OWNER FIXTURES. IS REPAIR PROPERTY DAMAGE BY THE INSTALLERS TO A LIKE -NEW CONDITION OR REPLACE DAMAGED SURFACES AND MATERIALS OF THE PREVIOUSLY INSTALLED WORK BY OTHER TRADES, INSTALLERS AND S18CONTRACTOR6. 20. WERE REQUESTED BY THE OWNER TO CERTIFY CONFORMANCE TO TRADE STANDARDS OR THE PROJECT REQUIREMENTS, THE CONTRACTOR SHALL ENLIST A TESTING LABORATORY AT THE OWNER'S COST. F THE REQUESTED TEST SHOWS NON-CONFORMANCE TO GENERALLY ACCEPTED TRADE STANDARDS OR THE PROJECT REQUIREMENTS, THE CONTRACTOR SHALL CORRECT THE DEFICIENCY AT NO ADDITIONAL COSTS TO THE OWNER AND REIMBURSE ALL THE COSTS OF THE TESTING TO THE OWER UNLESS THE CONTRACTOR HAS USED PRODUCTS INCORRECTLY LABELED BY THE MANUFACTURER OR HAS MADE PREVIOUSLY APPROVED CHANGES. 21. PROVIDE SECURITY OF THE WORK, INCLUDING TOOLS AND UNINSTALLED MATERIALS. PROTECT THE WORK, STORED PRODUCTS, CONSTRUCTION EQUIPMENT AND OWNER'S PROPERTY FROM THEFT AND VANDALISM AND THE PREMISES PROM ENTRY BY UNAUTHORIZED PERSONNEL UNTIL FINAL ACCEPTANCE BY OWNER- 22. WNER22 MAINTAIN AN ACTIVE FIRE EXTINGUISHER AT THE PROJECT. 23. DO NOT USE MATERIAL OR EQUIPMENT FOR ANY PURPOSE OTHER THAN THAT FOR WHICH IT 18 SPECIFICALLY DESIGNED OR SPECIFIED. ALL MATERIALS AND EQUIPMENT THAT ARE SIMILAR SHALL BE THE SAME TYPE, MODEL, AND STYLE FOR THE SAME USE THROUGHOUT THE PROJECT OR THEY SHALL BE REJECTED. 24. WHEN THE PROJECT REQUIREMENTS REQUIRE THAT THE INSTALLATION OF WORK SHALL COMPLY WITH MANUFACTURER'S INSTRUCTIONS, PERFORM THE WORK IN STRICT ACCORDANCE WITH THE STRICTEST CURRENT WRITTEN MANUFACTURER'S INSTRUCTIONS. 25. ALL PRODUCTS MID EQUIPMENT SHALL BE DELIVERED M UNDAMAGED CONDITION AND STORED IN ACCORDANCE WITH MANUFACTURER'S INSTRUCTIONS TO AVOID DISRUPTION OF THE WORK OR DAMAGE TO THE ITEMS. REPLACE DAMAGED OR UNFIT MATERIALS AT NO COST TO THE OWER 26. NOTIFY THE OWNER WEN THE WORK 15 SUBSTANTIALLY COMPLETE MID READY FOR FOR INSPECTION. UPON INSPECTION, PROVIDE WRITTEN OPERATION MID MAINTENANCE INSTRUCTIONS AND GUARANTEES FOR ALL EQUIPMENT AND MATERIALS INSTALLED. PROVIDE WRITTEN GUARANTEES FOR A PERIOD OF ONE (U YEAR FROM THE DATE OF FINAL ACCEPTANCE OF THE WORK. SEE CLOSE -OJT DOCI-IENTS FOR ADDITIONAL MATERIALS AND REQUIREMENTS. 21. GENERAL CONTRACTOR SHALL BE RESPONSIBLE FOR RECEIVING AND UNLOADING OF ALL FREIGHT (BUILD -OUT COMPONENTS) DELIVERED TO THE SITE. T415 SHALL INCLUDE: • LABOR FOR UNLOADING AND HANDLING OF ALL FREIGHT. • REMOVAL AND PROPER DISPOSAL OF PALLETS, DUNNAGE, PACKING MATERIALS, ETC. • INVENTORY OF ITEMS MID REPORTING OF M185MG COMPONENTS TO TED WING IMMEDIATELY. • INSPECTION OF ITEMS AND REPORTING DAMAGES TO RED WING AND AL50 NOTING ON BILL OF LADING WITH THE DELIVERY DRIVER 28. PROVIDE FINAL CLEAN-UP AND DAMAGE REPAIR AT THE PROJECT CONCLUSION. LEAVE THE PREMISES NEAT, CLEAN AND CLEAR OF TOOLS, EQUIPMENT AND S,1RBLUS MATERIALS UNLESS REQUESTED BY THE OWNER CLEAN-UP SHALL INCLUDE AND NOT BE LIMITED TO: a. POWER VACUUMING THE ENTIRE SPACE. b. HAND DUSTING AND CLEANING OF ALL SHELVING, CABINETRY, CASEUJORC GLASS AND MIRRORS BOTH INSTALLED UNDER THIS CONTRACT OR EXISTING, INCLUDING WALLS, CEILINGS, FIXTURES, ETC. c REPAIR OR REPLACEMENT OF PROPERTY DAMAGED DURING FINAL COMPLETION OF THE CONTRACT. d. MOP ALL FLOOR SURFACES, 29. NOTE: THE GENERAL CONTRACTOR IS RESPONSIBLE FOR COORDINATING ALL OF THE WORK OF THE PROJECT AND SHALL ENSUE THAT ALL OF THE SUBCONTRACTORS ARE AWARE OF ALL OF THE WORK INVOLVED AND THEIR RESPONSIBILITIES. DIVISION 2 - DEMOLITION / BUILDING ALTERATIONS L THE WORK MAY INCLUDE DEMOLITION OF EXISTING CONSTRUCTION, REMOVAL OF VARIOUS ITEMS OF EQUIPMENT AND CONSTRICTION, AND THE CUTTING OR ALTERATION OF EXISTING CONSTRUCTION AS SHOW, NOTED OR IMPLIED ON THE DRAWINGS. CONTRACTOR SHALL DETERMINE AND INVENTORY ALL NECESSARY DEMOLITION AND ALTERATION OF ITEMS TO PROVIDE FOR A COMPLETE INSTALLATION OF NEW WORK ALL COSTS OF REMOVAL, REPAIR OR REPLACEMENT SHALL BE INCLUDED IN THE BID. ADDITIONAL COSTS FOR DEMOLITION OF ITEMS WHICH COULD NOT REASONABLY BE ANTICIPATED APPROVAL PRIOR TO BEGINNING THE WORK. 2. AT ALTERED CONSTRUCTION, REPAIR CUT EDGES, REPLACE CONSTRICTION, AND FIT NEW TO EXISTING CONSTRUCTION TO MATCH EXI51M W10RC MAKE JOINTS OF NEW AND EXISTING PATCHES VERY SMOOTH, EVEN AND PRACTICALLY INVISIBLE. COORDINATE ALL REPLACEMENT AND REPAIR REQUIREMENTS WITH LANDLORD'S CONSTRICTION CRITERIA AND TENANT'S COORDINATOR 3. SAW -CUT CONCRETE WITH DIAMOND SAW: JACKHAMMERING WILL NOT BE PERMITTED EXCEPT WITH THE EXPRESSED WRITTEN APPROVAL OF THE LANDLORD. CUT IN ACCURATELY LOCATED STRAIGHT LINES, AND BREAK OUT SECTIONS. FLOOR MAY BE CORE DRILLED WHERE APPROPRIATE FOR NSTALLATION 0,16 ARE UNDER N CUTTING AS REQUIRED TO 4. DOORS 4 FRAMES: IF DOORS AND FRAMES ARE TO BE REUSED ON THE WORK, CAREFULLY REMOVE DOOR FROM FRAMES MID REMOVE FRAMES FROM OPENING, TAKING CARE TO AVOID DAMAGE, REMOVE HARDWARE, CLEAN, REFURBISH, AND STORE FOR REINSTALLAITON WHERE INDICATED. FOR DOORS AND FRAMES TO BE SALVAGED, CAREFULLY REMOVE FROM OPENING AND DELIVER FOR STORAGE WHERE INDICATED. PROTECT FROM DAMAGE. 5. PREVENT MOVEMENT OR SETTLEMENT OF STRUCTURE. PROVIDE AND PLACE BRACING MID SHORING AND BE RESPONSIBLE FOR SAFETY MID SUPPORT OF STRUCTURE, AS DETERMINED BY G.0 ENLISTED STRUCTURAL ENGINEER ASSUME LIABILITY FOR SUCH MOVEMENT SETTLEMENT DAMAGE OR INJURY. 6. ARRANGE AND PAY FOR DISCONNECTING, REMOVING AND CAPPING UTILITY SERVICES WITHIN AREAS AFFECTED BY DEMOLITION PLACE MARKERS TO INDICATE LOCATION OF DISCONNECTED SERVICES. LOCATE SPRINKLER SHUT-OFF VALVE AND SMOKE ALARM PRIOR TO COMMENCING WORK: COORDINATE REQUIRED MODIFICATIONS WITH LANDLORD. 7. CAREFULLY REMOVE MATERIALS AND EQUIPMENT WHICH ARE INTENDED TO BE BUSED. STOKE IN A SECURE LOCATION. REMOVE DEBRIS. REFUSE AND MATERIALS BEING DEMOLISHED IMMEDIATELY FROM THE SITE AND DISPOSE OF PROPERLY. RECYCLE ITEMS AND MATERIALS WERE FEASIBLE. 8. ERECT AND MAINTAIN WEATHERPROOF AND RUSTPROOF CLOSURES AID PARTITIONS TO PREVENT WEATHER DAMAGE OR SPREAD OF DUST, FUMES AND SMOKE TO OTHER PARTS OF THE BUILDING, IN ACCORDANCE WITH SHOPPING CENTER GUIDELINES AID STIPULATONS. a PERFORM DEMOLITION M ACCORDANCE WITH APPLICABLE AUTHORITIES HAVING JURISDICTION 10. REPAIR ALL DEMOLITION IN EXCESS OF THAT REQUIRED AT NO COST TO THE OWNER 11. REMOVE FROM SITE CONTAMINATED, VERMIN INFESTED, OR DANGEROUS MATERIALS ENCOUNTERED AND DISPOSE OF BY SAFE MEANS TO PROTECT HEALTH OF WORKERS AND PUBLIC. IV15ION 3 - CONCRETE REPAIR AND REPLACEMENT WORK INCLUDES PATCHING DEMOL164ED SLAB AND CERAMIC TILE, IF MY. FILLING AND LEVELING JOINTS AND CRACKS AND FILLING ABANDONED ELECTRICAL BOXES AND ANY HOLES GRATER THAN 1/211. USE RAECO-LITH "R-3511 AS UNDERLAYMENT FOR PATCHING OR APPROVED EQUAL MIX 644ALL BE TWO PARTS - MORTAR MIX AND LATEX BINDER MIX AND INSTALL PER MANUFACTURER'S LATEST WRITTEN AND RECOMMENDED DIRECTIONS. FREPARE CONCRETE SLAB FOR FINISHES AS DESCRIBED DIVISION 4 - NOT USED DIVISION 5 - METAL FABRICATIONS (WHERE APPLICABLE) L PROVIDE ALL MISCELLANEOUS METAL ITEMS INCLUDING MATERIALS, FABRICATIONS, FASTENINGS, AND ACCESSORIES REQUIRED FOR FINISHED NSTALLATION AS INDICATED AND SPECII 2. STEEL SHALL BE ASTM A366 AMERICAN OPEN HEARRN SHEET STEEL. FREE PROM SCALE AND PITTING AND OTHER DEFECTS AFFECTING APPEARANCE. 3. TUBING SHALL CONFORM TO REQUIREMENTS OF ASTM A500 OR ASO] AS APPROVED. 4. WHERE METAL ITEMS ARE TO BE ERECTED AND IN CONTACT WITH DISSIMILAR MATERIALS, PROVIDE CONTACT SURFACES WITH COATING OF AN IMPROVED ZINC CHROMATE PRIMER IN MANNER TO OBTAIN NOT LESS THAN 10 MIL DRY FILM THICKNESS. 5. SHEET STEEL SHALL CONFORM TO REQUIREMENTS OF ASTM A606. 6. CARBON STEEL BARS SHALL CONFORM TO REQUIREMENTS OF ASTM A32L 1. ALUMINUM EXTRUSIONS SHALL CONFORM TO ASTM 8221. REVEALS TO BE BLACK ANODIZED FINISH (UNLESS OTHERWISE NOTED). S. FASTENERS SHALL BE AS REQUIRED FOR ASSEMBLY AND INSTALLATION OF FABRICATED ITEMS. 9. BOLTS SHALL BE LOU CAR30N STEEL EXTERNALLY AND INTERNALLY THREADED FASTENERS CONFORMING WITH REQUIREMENTS OF ASTM A301. INCLUDE NECE66ARY NUTS AND PLAIN HARDENED WASHERS. FOR MEMBERS FOR SUPPORT OF STRICWRAL MEMBERS OR CONNECTION THERETO. USE FASTENERS CONFORMING WITH ASTM A325. FOR STAINLESS STEEL AND NON-FERROUS ITEMS. USE TYPE 302 AND 304 STAINLESS STEEL FASTENERS. 10. MISCELLANEOUS MATERIALS: PROVIDE ALL INCIDENTAL ACCESSORY MATERIALS, TOOLS, METHODS, AND EQUIPMENT REQUIRED FOR FABRICATION AND INSTALLATION OF MISCELLANEOUS METAL ITEMS AS INDICATED ON DRAWINGS. IL VERIFY DIMENSIONS PRIOR TO FABRICATION OR CASTING FORM METAL ITEMS TO ACCURATE SIZES AND CONFKGURATIONS AS INDICATED ON DRAWINGS AND OTHERWISE REQUIRED FOR FROPER INSTALLATION, FABRICATE WITH ALL LINES STRAIGHT AND ANGLES SHARP, CLEAN AND TRUE: DRILL, COUNTERSINK, TAP, AND OTHERWISE PREPARE ITEMS FOR CONNECTION WITH WOW OF OTHER TRADES, MAKE PERMANENT CONNECTIONS BY WELDING AND GRIND ALL EXPOSED WELDS SMOOTH TO MATC4 ADJACENT SURFACES: ROUGH JOINT SURFACES NOT PERMITTED. AVOID USING BOLTS AND SCREWS UNLESS SPECIFICALLY INDICATED OR APPROVED. WHEN USED, DRAW UP TIGHT AND TIE THREADS TO PREVENT LOOSENING. R. ALL FERROUS METAL ITEMS SHALL BE SHOP FINISHED. TOUCH-UP OR REPAIR DAMAGED AREAS PRIOR TO INSTALLATION WITH SAME MATERIAL. 13. PROVIDE CONTACT SURFACES Wil CONCRETE MASONRY OR OTHER DISSIMILAR MATERIALS WITH A MINIMUM ONE POINT ZERO (IID) MIL DRY THICKNESS OF AN APPROVED ZINC CHROMATE PRIMER 14. PROVIDE ALL STEEL BLOCKING AND BRACING IN METAL SND FRAMED PARTITIONS NECESSARY FOR A COMPLETE INSTALLATION INCLUDE AS REQUIRED FOR SUPPORT OF ALL WALL -MOUNTED EQUIPMENT AND FABRICATION$ AS INDICATED ON DRAWNGS. PROVIDE SUPPORTS AT JAMBS OF DOORS AND ELSEWHERE, AS REQUIRED. 15. FABRICATE ALL MISCELLANEOUS FRAMING AND BRACING ITEMS TO DETAIL OF STRUCTURAL SHAPES, PLATES, AND BARS. WELD JOINTS UIHERE PRACTICAL. PROVIDE BOLTS MID OTHER CONNECTION DEVICES REQUIRED. INCLUDE ANCHORAGES, CLIP ANGLES, SLEEVES, ANCHOR PLATE, AND SIMILAR DEVICES, WHETHER IMPLIED OR INDICATED. SET ACCURATELY IN POSITION AS REQUIRED AND ANCHOR SECURELY TO BUILDING CONSTRUCTION WITH FASTENERS APPROPRIATE TO THE INSTALLATION Alan J.Fllutowski ARCHITECT 4125 Lakeland Ave. N., Suite 200 Minneapolis, Minnesota 55422 763.533-7171 fax: 763.533-7979 Consultants MVA D OP RED WING SHOES 314MM MM Rm NAM eN ssaa FMNE (PW) 733Ks t FM (eel) 361 Certification Project Information RED WING SHOES BUILD -OUT FOR NEW DEALER STORE Red Ming Shoe Store 9879 N. Michigan Rd, Suite 120 Carmel. Indiana 46092 Revisions Date: 04/06/18 Drawn By: BG Checked By: NIP, BC Job Number: 1811W -W7 Sheet Information T1 a2