HomeMy WebLinkAboutGN0T1.3DIVISION 6 - WOODS 4 PLASTICS NOTE: PROVIDE WOOD C40NSTRJCTION ONLY WHERE PERMITTED FOR THE TYPE OF CONSTRICTION IN NON-COMBUSTIBLE BUILDINGS, PROVIDE ONLY FIRE -TREATED WOOD BLOCKING WHERE PERMITTED I. PROVIDE ROUGH LUMBER AND PLYWOOD IN STANDARD DIMENSIONS, MOISTURE CONTENT NOT MORE THAN B%. 2. PROVIDE ALL NECESSARY ROUGH HARDWARE M SIZES IN QUANTITIES REQUIRED BY LOCAL CODE OR APPROVED BY ARCHITECT. 3. USE FINISH OR CASING NAILS FOR EXPOSED WORK: USE TYPE 115" TRIM HEAD 8CREW5 FOR ATTACHMENT OR WOOD TRIM TO METAL STUDS, RUNNERS, OR FURRINNG. 4. RELIEVE BACKS OF WOOD TRIM. KERF BACKS OF MEMBERS MORE THAN 5" WIDE AND I" NOMINAL THICKNESS. EASE ALL EXTERNAL CORNERS. B. INSTALL LAMINATES ONLY WHEN RECEIVING SURFACES ARE IN A SATISFACTORY CONDITION FOR INSTALLATION. 6. USE ADHESIVES RECOMMENDED BY THE MANUFACTURER FOR THE PARTICULAR APPLICATION. INSTALL IN ACCORDANCE WITH MANUFACTURER'S MOST CURRENT PRINTED APPLICATION INSTRUCTIONS. 1. PROTECT FROM DAMAGE BY OTHER TRADES WORKING ADJACENT TO THE INSTALLATION REPLACE DAMAGED SURFACES. 8. REMOVE EXCESS ADHESIVE AND CLEAN SURFACES USING MANUFACTURER'S RECOMMENDED SOLVENT AND CLEANING PROCEDURES. a FILL IN ALL SEAMS WITH MANUFACTURER'S APPROPRIATE COLOR SEAM COMPOLI 10. INSTALL WOODS AND PLASTICS IN CONFORMANCE WITH DETAILS. WITH THE FOLLOWING CONSIDERATIONS AND REQUIREMENTS: a. INSTALL ALL MATERIAL WITH TIGHT JOINTS. b. MITER CASINGS AND MOLDINGS. a All RUNNING TRIM ONE (U PIECE UP TO 10'-0'l MATCH GRAIN AND COLOR PIECE TO PIECE. d. USE FINISH NAILS EXCEPT WHERE SCREWS ARE SPECIFICALLY CALLED FOR OR WHERE SCREWS DO NOT SHOW. e. SET FASTENERS FOR PUTTYING. F. WHERE SCREW ATTACHMENT 15 REQUIRED, SPACE SCREWS AT EQUAL INTERVALS. SINK AND PUTTY N FINISHED WOOD SURFACES. g. ALL MEMBERS AND LNES LEVEL AND PLUMB. K SELECT AND CUT MATERIAL TO EXCLUDE DAMAGED, MARKED, OR DEFECTIVE AREAS. I. FINISH EXPOSED BURFACE9 SMOOTH, FREE FROM TOOL AND MACHINE MARCS. J. EASE ALL EXPOSED WOOD EDGES I/8" MINIMUM RADIUS. k INSTALL FIRE RATED DOORS IN ACCORDANCE WITH REQUIREMENTS OF NATIONAL FIRE PROTECTION ASSOCIATION (Ni RECOMMENDATIONS - 11 ECOM MENDATIONS-11. ALL WOOD BLOCKING, FRAMING, PLYWOOD, ETC. SHALL BE FIRE RETARDANT TREATED. DIVISION T - SEALANTS AND CAULKING I. PROVIDE NON -SAG SEALANT COMPLYING WITH REQUIREMENTS OF FEDERAL SPCIFICATIONS TTS -1543 OR FS 77-5-230 TYPE "II", CLASS "A". PROVIDE ACOUSTICAL SEALANT WHICH SHALL BE NON -HARDENING, NON-DRYNG SYNTHETIC RIBBER SEALING COMPOUND WITH MINIMUM 90% SOLIDS. USE AT ALL INTERIOR JOINTS AT INTERSECTIONS BETWEEN PLANES. AROUND DOOR AND WINDOW FRAMES PRIMER SHALL BE MADE AS RECOMMENDED BY SEALANT MANUFACTURER FOR THE SPECIFIC CONDITIONS AND SUBSTRATES. 2. PROVIDE BACKING MATERIAL BY DOW "ETHAFOAI" OR APPROVED EQUAL. APPLY SEALANT OVER BACKING TO UNIFORM THICKNESS IN CONTINUOUS BEADS FILLING ALL JOINTS AND VOIDS SOLID. SUPERFICIAL POINTING WITH THE SKIM BEAD WILL NOT BE ACCEPTED. 3. ALL SURFACES SHALL BE ADEQUATELY CLEANED AND PREPARED IN ACCORDANCE WITH MANUFACTURERS WRITTEN NSTRICTIONS PRIOR TO INSTALLATION. DIVISION S - WOOD AND HOLLOW METAL DOORS 4 FRAMES I. PROVIDE KNOrK-DOWN 2" DOOR FRAMES AT ALL G.C. PROVIDED DOORS, FREE FROM SCALE AND PITTING AND OTHER SURFACE DEFECTS, UNLESS OTHERWISE NOTED. PROVIDE DOOR BUMPERS ON ALL FRAMES WITH STOPS. INSTALL NEATLY, PLUMB WITH TIGHT JOINTS. 2. PROVIDE HOLLOW METAL EXIT DOOR CONSTRUCTED WITH THE FOLLOWING MATERIALS: - MINIMUM 18 GA FOR FACE SHEETS OF INTERIOR DOORS - 16, GA FOR EDGE CHANNELS. - MINIMUM 22 GA FOR FACE STIFFENERS. - MINIMUM 15 GA FOR INTERIOR FRAMES. 3. PROVIDE DOORS OF SIZES AND TYPES INDICATED ON DRAWINGS, FULLY WELDED SEAMLESS CONSTRUCTION WITH NO VISIBLE SEAMS OR JONTS ON FACES OR VERTICAL EDGES. THICKNESSES AS SCHEDULED ON DRAWINGS. 4. FACE STIFFENERS, EDGES AND HARDWARE REINFORCEMENT 844ALL BE THE HIGHEST QUALITY WORKMANSHIP AND MATERIALS. PROVIDE IN ACCORDANCE WITH BEST MADE PRACTICE AND MANUFACTURER'S WRITTEN RECOMMENDATIONS FOR THE USE INTENDED. 5. PROVIDE CUSTOM MADE WELDED UNITS WITH INTEGRAL TRIM. SIZES AND SHAPES AS INDICATED ON DRAWINGS. FABRICATE UNITS SQUARE, TRE AND REE FROM DEFECTS, 6. HARDWARE REINFORCEMENT AND ANCHORS (ERECTION, FLOOR AND JAMB) SHALL BE AS REQUIRED FOR A SECURE INSTALLATION MID SHALL BE IN ACCORDANCE WITH TRADE REQUIREMENTS FOR THE SPECIFIED HARDWARE AND INTENDED USE. 1. AFTER FABRICATION, DRESS, FILL AND SAND EXPOSED SURFACES, BODY-PIUTTY HOLES AND IMPEIRFECTION5. APPLY UNIFORM COAT OF MANUFACTURER'S STANDARD PRIME COAT TO ALL EXPOSED SURFACES. LEAVE READY TO RECEIVE FINISH PAINTING. 8. INSTALL FRAMES IN ACCURATE LOCATIONS AS INDICATED ON DRAWINGS. INSTALL RIGID, PLUMB, LEVEL AND TRUE. ALIGN WITH ADJACENT CONSTRUCTION SECURE FLOOR ANCHORS TO FLOOR CONSTRICTION WITH APPROVED TYPE MECHANICAL FASTENINGS. ANCHOR TO ADJOINING WALLS WITH SPECIFIED ANCHORS. BRACE FRAMES TO RETAIN POSITION AND CONTINUOUSLY CHECK ALIGNMENT DURING CONSTRICTION OF ADJACENT WALLS. ADJUST FRAME LOCATIONS AS NECESSARY USING SHIMS BEFORE FASTENING. LEAVE READY TO RECEIVE SEALANT WHERE INDICATED ON DRAWINGS. 9, INSTALL WOOD DOORS, FRAMES, AND TRIM. SIZES AND THICKNESS AS SCHEDULED ON THE DRAWINGS. 10. PREPARE DOORS FOR FINISH HARDWARE. OBTAIN TEMPLATES FROM HARDWARE MANUFACTURER AND CONFIRM TYPE, LOCATION AND SPECIAL REQUIREMENTS OF HARDWARE FOR EACH DOOR PRIOR TO CUTTING. It HAW DOORS AS SCHEDULED ON DRAWINGS, IN ACCURATE LOCATIONS WITH 1/8" CLEARANCE AT TOPS AND 3/8 CLEARANCE AT BOTTOM. UNLESS SPECIFICALLY NOTED FOR "UNDERCUTS" OR OTHER DEVIATIONS IN FIT. VERIFY CLEARANCES REQUIRED FOR CARGETNG AND MAKE NO JOBBITE FIT IN OUTS WINLESS APPROVED. HANG PAIRS OF DOORS AS SPECIFIED WITH 3/32" CLEARANCE AT MEETING EDGES. DEMONSTRATE THAT DOORS OPEN FREELY WITHOUT BINDING AND WHEN CLOSED, WILL LATCH PROPERLY. 12. ACCESS DOORS (PROVIDED BY GENERAL CONTRACTOR): PROVIDE ACCESS DOORS BY MILCOR OR EQUAL. USE STYLE DW AT WALLS AND CEILINGS, (OR AS REQUIRED FOR RATING). SIZE AS INDICATED. FRAME SHALL BE GALVANIZED STEEL DRYWALL BEAD FOR FRAME CONCEALMENT. PANEL SHALL BE 14GA. STEEL WITH SPRING TYPE CONCEALED HINGES OPENING TO T5 DEGREES. LOCKS SHALL BE FLASH, SCREWDRIVER OPERATED WITH METAL CAN. PRIME COAT SHALL BE FACTORY APPLIED, COORDINATE INSTALLATION WITH REQUIREMENTS OF OVERHEAD COILING DOOR MANUFACTURER RELEASED FOR CONSTRUCTION Subject to compliance with all regulaiions of State and Uncal Codes City of Camel DATE: 06/06/18 HARDWARE I. ALL FINISH HARDWARE FOR COMPLETE WOR, 844ALL BE FURNISHED AND INSTALLED M ACCORDANCE WITH DRAWINGS AND SPECIFICATIONS. QUANTITIES LISTED M ANY INSTANCE ARE FOR THE CONTRACTOR'S CONVENIENCE ONLY AND ARE NOT GUARANTEED. ITEMS NOT SPECIFICALLY MENTIONED BUT NECE58ARY TO COMPLETE THE UKORG FURNISHED. MATCHING IN QUALITY AND FINISHED THE ITEMS SPECIFIED. 2. THE CONTRACTOR SHALL. BE RE5PON5IBLE FOR PROPER OPERATION AND FITTING OF HARDWARE IN LOCATIONS SPECIFIED. THE CONTRACTOR MUST SUPPLY A ROOM UNDER LOCK AND KEY TO STORE ALL FINISH HARDWARE UNTIL INSTALLATION 15 MADE. THE HARDWARE SUPPLIER MUST MARC EACH ITEM OF HARDWARE AS TO DESCRIPTION AND LOCATION OF INSTALLATION IN ACCORDANCE WITH APPROVED HARDWARE SCHEDULE. EXPOSED SURFACES OF HARDWARE SHALL. BE COVERED AND WELL PROTECTED DURING INSTALLATION, 80 AS TO AVOID DAMAGE TO FINISHES 3. PROVIDE HARDWARE FOR FIRE -RATED OPENINGS M COMPLIANCE WITH REQUIREMENTS OF NFPA 80. THIS REQUIREMENT TAKES PRECEDENCE OVER OTHER REQUIREMENTS FOR SUCH HARDWARE. 4. HARDWARE TO BE Si "AL -SERIES' WITH A BRUSHED SATIN CHROME 26D/626 FINISH. ALL HANDLES SHALL BE ADA LEVER STYLE. B. HARDWARE SUPPLIER WILL PROVIDE APPROVED SCHEDULED AND PAPER TEMPLATES TO VARIOUS OTHER SUPPLIERS FOR DOOR MID FRAME PREPARATION FOR HARDWARE. 6. RIR415H MID FINISH HARDWARE, CYLINDERS AND KEYS, "BEST" SEVEN PM ROD. 1. EACH ITEM OF HARDWARE SHALL BE PACKAGED SEPARATELY WITH ALL NECESSARY SCREWS, BOLTS, TAMPING, KEYS AND INSTALLATION TEMPLATES. DELIVER PACKAGES, CLEAR_Y IDENTIFIED, WITH HEADING NUMBER AS APPROVED ON HARDWARE SCHEDULE. S. INSTALL EACH HARDWARE ITEM IN ACCORDANCE WITH THE MANUFACTURER'S WRITTEN INSTRUCTIONS AND RECOMMENDATIONS AND LOCATE N ACCORDANCE WITH THE RECOMMENDED LOCATIONS. 5ET ITEMS LEVEL, PLUM, AND TRUE TO LINE MID LOCATION ADJUST AND REINFORCE THE ATTACHMENT SUBSTRATE, AS NECESSARY, FOR A SECURE INSTALLATION SPACE FASTENERS AND ANCHORArE AS INDICATED OR N ACCORDANCE WITH INDUSTRY STANDARDS. S. MAKE FINAL ADJUSTMENT AND CHECK OF HARDWARE DURING THE WEEK IMMEDIATELY PRIOR TO RESTORE PROPER FUNCTIONING AND FINISH OF HARDWARE AND DOORS. MAKE FINAL ADJUSTMENT OF LOCKSETS MID THE CLOSURES, TO COMPENSATE FOR OPERATION OF HEATING AND VENTILATION SYSTEMS UNDER THE SUPERVISION OF MANUFACTURERS REPRESENTATIVE. 10. LUBRICATE ALL MOVING PARTS WITH GRAPHITE -TYPE LUBRICANT, UNLESS OTHERWISE RECOMMENDED BY MANUFACTURER REPLACE ALL HARDWARE WHICH CANNOT BE LUBRICATED AND ADJUSTED TO OPERATE FREELY AND SMOOTHLY. PAINTING I. PROVIDE PAINT FINISHES FOR BUILDING AND OTHER SURFACES AS SCHEDULED ON DRAWINGS OR AS SPECIFIED HEREINAFTER INCLUDING SEALING OF CONCRETE FLOOR AT CORRIDOR AND STOCKROOM. NO PAINT FINISH 15 REQUIRED ON ITEMS HAVING COMPLETE FACTORY FINISH, EXCEPT AS MAY BE SPECIFIED HEREINAFTER PUTTY AND/OR SEALANT AT ALUMINUM WINDOWS. NON-FERROUS PETAL UNLESS SPECIFICALLY MENTIONED IN THE PAINING SCHEDULE. STAINLESS STEEL INTERIOR OR EXTERIOR OF EXI6TMG BUILDING EXCEPT WHERE ALTERATIONS OCCUR OR WHERE SCHEDULED. PAINT GRILLES AND DIFFUSERS. NO PAINTING 15 REQUIRED FOR INSULATED PIPING, EXCEPT WHERE EXPOSED IN FINISHED NON-MECHANICAL ROOM SPACES. 2. PROTECT WORK OF OTHER TRADES FROM DAMAGE AID DEFACEMENT CAUSED BY THIS WK)RC REPAIR ANY DAMAGE CAUSED BY THE WI OF THIS SECTION. REMOVE ELECTRICAL OUTLETS AND SWITCH PLATES, MECHANICAL DIFFUSERS, GRILLES, ESCUTCHEONS, REGISTERS, SURFACE HARDWARE, FITTINGS, AND FASTENINGS PRIOR TO COMMENCING THE WOW STORE, CLEAN, AND REPLACE UPON COMPLETION. 3. PAINT CONTRACTOR SHALL NOTIFY THE GENERAL CONTRACTOR IF ANY SURFACE TO BE PAINTED OR STAINED 15 FOUND TO BE UNSUITABLE TO PRODUCE PROPER FINISH. APPLY NO FINISH MATERIAL UNTIL THE UNSUITABLE SURFACES HAVE BEEN MADE SATISFACTORY. 4. FNI5H WOW SHALL BE UNIFORM, OF APPROVED COLOR, SMOOTH AND FREE FROM RUNS. MAKE ENDS OF PAINT ADJONNG OTHER MATERIALS OR COLORS SHARP AND CLEAN. WHERE HIGH GLO55 ENAMEL 15 USED, LIGHTLY SAID (UNDERCOAT TO OBTAIN A SMOOTH FINISH COAT. 5. PROVIDE ALL NEWLY PAINTED SURFACES WITH (U COAT TINTED PRIMER AND (2) COATS FINAL COLOR COAT, UNLESS OTHERWISE RECOMMENDED BY MANUFACTURER'S SPECIFICATIONS. 6. DELIVER ALL PAINT TO JOB5ITE IN UNOPENED CONTAINERS BEARING THE MANUFACTURER'S LABEL, AND SHOWING PAINT TYPE, SHEEN, AND COLOR 1. PAINT TYPES USED SHALL BE THOSE SPECIFICALLY RECOMMENDED BY THE MANUFACTURER FOR THE MATERIAL TO WHICH THEY WILL BE APPLIED. PAINTING CONTRACTOR SHALL FOLLOW MANUFACTURERS INSTRUCTIONS FOR PROPER APPLICATION OF THE PAINT. S. ALL SURFACES TO BE PANTED SHALL BE THOROUGHLY CLEANED AND PREPARED FOR PAINTING PRIOR TO APPLICATION OF PAINT. PROVIDE VENTILATORS AS REQUIRED TO PREVENT BUILD-UP OF RJMES. S SAND ALL NEW UOOD TO SMOOTH AND EVEN SURFACE AND DUST OFF AFTER PRIMING COAT HAS BEEN APPLIED. THOROUGHLY FILL ALL NAIL HOLES AND OTHER SURFACE IMPERFECTIONS WITH PUTTY TINTED WITH PRIMER OR STAIN TO MATCH WOOD COLOR SAND ALL WOODWORK BETWEEN COATS TO A SMOOTH SURFACE. DIVISION 10 - SPECIALTIES I. ALL ACCESSORIES TO BE SURFACE MOUNTED TYPE. 2. ACCESSORIES TO BE "BOBRCK" OR APPROVED EQUAL - BRUSHED OR CHROME FINISH UNNO. ACCESSORIES (VERIFY EXISTING CONDITIONSTO MET CODEI SPA TOILET PAPER HOLDER - BY LANDLORD. SP -2 SOAP DISPENSER - INSTALLED AND SUPPLIED BY GC. 51 MIRROR (18" X 3617 - BY LANDLORD. 51 GRAB BARS - BY LANDLORD. Si PAPER TOWEL DISPENSER - BY LANDLORD. EP -6 TRASH CONTAINER - SELECTED AND PROVIDED BY TENANT SP -1 SIGNAGE AT RESTROOM DOOR TO MEET APPLICABLE ACCE551BILITY CODE - VERIFY - INSTALLED AND SUPPLIED BY LANDLORD AS REQUIRED. 51 LAVGUARD2 (ANDER SINK PIPE INSULATING COVERS - INSTALLED AND SUPPLIED BY GC. Si CORNER GUARDS - PROVIDE 4 INSTALL IN DESIGNATED LOCATIONS, WHERE SHOWN ON THE FLOOR PLAN. CORNER GUARD SHALL BE: I"xl"x48" L -SHAPED CLEAR LEXAN WITH NAIL OR SCREW ATTACHMENTS OVER PAINTED WALL - BY LANDLORD. INSTALLATION: I. DELIVER NSERTS AND ROUGH -IN FRAMES TO J056ITE AT APPROPRIATE TIME FOR ROUGHING N. 2. FASTENINGS: FURNISH TOILET ACCESSORIES TO COMPLETE WITH ALL REQUIRED MOUNTING DEVICES, FASTENING, AND ACCESSORIES AS REQUIRED FOR A FINISHED INSTALLATION, PROPERLY PACKAGED AND TMT ED FOR READY IDENTIFICATION. FASTEN ALL ITEMS WITH SOLUS OR BOLTS EXTENDING AT LEAST I" INTO SOLID BACKING IF NO OTHER FASTENING IS SPECIFIED, 3. INSTALLATION OF TOILET ACCESSORIES SHALL BE IN ACCORDANCE WITH THE DRAWINGS, REVIEWED SHOP DRAWINGS, AND THE MANUFACTURER'S INSTALLATIONS AND RECOMMENDATIONS ALONG WITH ALL GOVERNING NATIONAL, STATE AND LOCAL CODES PERTAINING TO HANDICAPPED ACCESSIBILITY. 4. GC. SHALL VERIFY, SUPPLY 4 INSTALL ADEQUATE BACKING FOR SECURE INSTALLATION OF ALL ACCESSORIES. MOUNTING: I. LOCATIONS AND HEIGHTS SHALL BE AS SHOWN ON DRAWINGS AND IN CONFORMANCE WITH 'HANDICAP' ORDINANCES. SIGNS: 10. PRIME ALL SURFACES THAT RECEIVE PAINT PRIOR TO APPLICATION OF FINAL FINISH, IN I. SIGNS ARE SUPPLIED 4 INSTALLED BY OWNER'S SIGN CONTRACTOR GC. SHALL PROVIDE POWER ACCORDANCE WITH MANUFACTURERS SPECIFICATIONS. SOURCE 4 REQUIRED DISCONNECTS, TIME CLOCKS ETC. COORDINATE WITH SIGN CONTRACTOR AS 11. BACK PRIME ALL EXTERIOR D INTERIOR WOOD AND TRIM PRIOR TO INSTALLATION THOROUGHLY SQUIRED. AND CLEAN SURFACES AND APPLY NO FINISH UNLESS SURFACES ARE DRY AND READY FOR APPLICATION. SAND SURFACES OF TRIM SMOOTH AND WIPE CLEAN. AFTER STAIN COAT HAS BEEN APPLIED, FILL CRACKS AND HOLES WITH PLASTIC WOOD OR PATTY. IF STAIN HAS BEEN USED, TINT CRACK FILLER TO MATCH. PRIME BACKS OF TRIM. PRIME BARE WOOD SCHEDULED TO RECEIVE PAINT FINISH FINISH NAIL HOLES, CRACKS, AND OTHER IMPERFECTIONS WITH PUTTY AND SAND SMOOTH. 12. AT COMPLETION, TOUCH-UP AND RESTORE FINISH WHERE DAMAGED AND LEAVE ALL SURFACES M GOOD AND CLEAN CONDITION PROVIDE FOR MULTIPLE CITE VISITS AS REQUIRED FOR TOUCH -IJP AND REFINISHING. 13. OTHER PAINT MANUFACTURERS MAY NOT BE SUBSTITUTED. 14. FIN15H INTERIOR SURFACES, AS SCHEDULED ON DRAWINGS, EXCEPT AS MODIFIED AND SUPPLEMENTED HEREINAFTER AND UPON WRITTEN OWNER APPROVAL. IN GENERAL, UBE EGGSHELL SHEEN FOR WALL BOARD SURFACES. SEMI -GLOSS FOR HOLLOW METAL AND WOOD TRIM AND FLAT FOR DUCTWORK 15. W14ERE APPLICABLE: DESIGNATED PATHWAYS IN STOCK ROOM ON FLOOR SHALL BE OF BRIGHT YELLOW TAPE OR NEATLY MASKED OFF PAINT. EITHER METHOD SHALL HAVE AN APPROPRIATE CLEAR SEALER / FINISH OVER IT FOR PROTECTION AND DURABILITY. RESILIENT BASE 4 FLOOR I. INSTALL COVE BASE IN AREAS AS CALLED FOR IN PLANS 4 OR ELEVATIONS. PROVIDE IN ROLL STOCK FORMAT IN LIEU OF STRAIGHT SECTIONS. 2. PROVIDE PREMOLDED INSIDE AND OUTSIDE CORNERS FOR ALL CONDITIONS AT WHICH CORNERS ARE TO BE USED. JOB MITERING SHALL BE PERMITTED ONLY UPON OWNER'S APPROVAL. 3. WHERE SHOWN, VINYL COMPOSITION TILE TO BE ARMSTRONG STANDARD EXCELON IMPERIAL TEXTURE CLASSIC WHITE 91911 AND SHALL BE A CLASS I FINISH TO MEET ALL APPLICABLE BUILDING CODE FINISH REQUIREMENTS. INSTALL PER MANUFACTURER'S INSTRUCTIONS. SEE PLAN FOR LOCATIONS. 4. USE ADHESIVES ONLY AS RECOMMENDED BY THE MANUFACTURER OF THE MATERIAL TO WHICH IT IS APPLIED, S. CAREFULLY INSPECT ALL SURFACES TO RECEIVE BASE AND / OR VINYL FLOOR PRIOR TO INSTALLATION. REPAIR DAMAGED OR UNEVEN SURFACES PRIOR TO INSTALLATION. b. UPON COMPLETION, IMMEDIATELY REMOVE ALL SURIPLUS ADHESIVE FROM ADJACENT SURFACE, IN ACCORDANCE WITH THE TIMING RECOMMENDED BY THE MANUFACTURER USING MATERIALS RECOMMENDED FOR TWAT PURPOSE BY THE MANUFACTURER FIRE EXTINGUISHERS (PROVIDED BY G.G.): I. NEW EXTINGUISHERS SHALL BE I0 -POUND CAPACITT, DRY CHEMICAL, U.L. LABEL 4A-5084, ENAMELED STEEL CONTAINER WITH PRESSURE INDICATING GAUGE. 2. INSTALL ON WALL MOUNTED HOOKS AS INDICATED OR DIRECTED BY FIRE MARSHAL, NEATLY FITTING TO FINISH SURFACES. PLACE FULLY CHARGED EXTINGUISHERS ON HOOKS PRIOR TO OCCUPANCY. 3. SEE FIXTURE PLAN FOR ARCHITECTS SUGGESTED LOCATIONS - VERIFY WITH FIR= MARSHAL. GYP5UM BOARD WALLS AND CEILINGS: I. PROVIDE GYT56M WALL PANELS MANUFACTURED IN ACCORDANCE WITH REQUIREMENTS OF ASTM 336. 2. PROVIDE TYPE 'X' FRE RETARDANT GYPSUM BOARD PANELS 5/8" THICK LISTED 4 QUALIFIED FOR 1-14OUR RATING TAPERED AND ROUNDED AT EDGES AS INDICATED ON DRAWINGS. 3. PROVIDE METAL EDGE AND GARNER BEADS AT ENDS, EDGES AND CORNERS. WATER RESISTANT GYPSUM WALL BOARD SHALL BE 5/8" THICK QUALIFIED FOR I -HOUR RATING, TAPERED AND ROUNDED EDGES AND SHALL BE INSTALLED IN ALL WET AREAS ADJACENT TO SINKS, TOILETS, AND / OR URNALS AS INDICATED 014 DRAWINGS. 4. PROVIDE FASTENERS IN ACCORDANCE W/ ASTM C646. UNLESS OTHERWISE NOTED OR INDICATED. PROVIDE TYPE 'S' BUGLE HEAD SCREWS FOR ATTACHMENT OF WALL BOARD TO METAL FRAMING, AND TYPE 'S' PAN HEAD SCREWS FOR ATTACHMENT OF FRAMING TO DOOR FRAMES. S. PROVIDE ALL INCIDENTAL 4 ACCESSORY MATERIALS, TOOLS, EQUIPMENT, AND METHODS REQ'D FOR SATISFACTORY COMPLETION OF GYPSUM WALL BOARD CONSTRICTION INCLUDING ACCESS DOORS AND PANELS, 6. APPLY CONTINUOUS BEAD SEALANT AT ALL JOINTS OF WALL BOARD ABUTTING ADJACENT CONSTRUCTION, INCLUDING AROUND FRAMED OPENINGS AND OTHER PROTRUSIONS THROUGH WALL BOARD WHERE SEALANT 15 EXPOSED. PROVIDE POLYSULFIDE SEALANT WHERE UNEXPOSED. PROVIDE ACOUSTIC SEALANT. PROVIDE J -BEAD AT ALL OUTSIDE PANEL EDGES, CORNER BEAD AT ALL CORNERS. 1. APPLY PRE-FlLL COMPOUND TO JOINTS IN ACCORDANCE WITH INDUSTRY STANDARDS. APPLY EMBEDDING COMPOUND REINFORCING TAPE CENTERED OVER JOINT. APPLY SKIM COAT. AFTER TAPING 4 EMBEDDING COMPOUND 15 DRY, APPLY SECOND COAT FILLING 4 TAPER FLUSH W/ SURFACE. FIRE TAPE PENETRATIONS AT DEMISNG WALLS, CORRIDOR ENVELOPE 4 OTHER RATED ASSEMBLIES. S. PROVIDE FINAL FINISH ON ALL EXISTING AND NEW SALES ROOM GYPSUM BOARD WALLS AND CEILINGS (IF ANY) THAT IS SMOOTH, LEVEL 5 FNISH PER GYPSUM ASSOCIATION DOCUMENT GA 214-1 WITHOUT DIVOTS, BUMPS, MARCS, JOINTS, 50115 OR ANY OTHER SURFACE BLEMISH OR IMPERFECTION, READY TO RECEIVE PAINT. SOUND ABSORPTION PANELS: INSTALL 2'x W SCNEX VALUELINE 53H BOUND PANELS (WITH CLASS I FIRE RATING) PROVIDED BY TENANT TO UNDERBIDE OF EXISTING METAL ROOF DECK IN SHOWROOM PER MANUFACTURER'S SPECIFICATIONS AFTER OPEN CEILING PANTING 15 COMPLETED. COORDINATE INSTALLATION WITH MEP COMPONENTS. PROVIDE PA -02 ADHESIVE PER MANUFACTURERS RECOMMENDATIONS. SPRAY ADHESIVE TO UNDERSIDE OF ROOF DECK 4 TO TOP OF PANEL PRIOR TO INSTALLATION CUT/ADJU8T PANELS AS NEEDED FOR A TIGHT FIT TO THE METAL DECK Y TO ABBREVIATIONS ACT ACOUSTIC CEILING TILE EX EXISTING TO REMAIN FOIC FURNISHED BY OWNER INSTALLED BY CONTRACTOR FOIO FURNISHED BY OWNER INSTALLED BY OWNER GYP GYPSUM BOARD PT PAINT UNO UNLESS NOTED OTHERWISE VB VINYL BASE VCT VINYL COMPOSITION TILE Alan J.Fllutowski ARCHITECT 4125 Lakeland Ave. N., Suite 200 Minneapolis, Minnesota 55422 763.533-7171 fax: 763.533-7979 Consultants ,�3�DD RED WING SHOES 3NF. MM MM wa waw Sam PHONE (PW) 73 M FM (ml) 361 Certification Project Information RED WING SHOES BUILD -OUT FOR NEW DEALER STORE Red fling Shoe Store 9879 N. Michigan Rd, Suite 120 Carmel, Indiana 46092 Revisions Date: 04/06/18 Drawn By: BG Checked By: UIP, BC Job Number: IBRV-07 Sheet Information rrrrrrrrrrrrrrrrr rr>rF :rs-:rr:>.Tcr;�Ir.n4rmr:�r1 T1 w3