HomeMy WebLinkAboutM11.0PACKAGED ROOFTOP AIR
HANDLING UNIT
STING GAS LINE & BALL 1
_VE. VERIFY IN GOOD
NDITION AND OPERABLE.
NTRACTOR SHALL VERIFI'
STING PIPING SUPPORT IS
DE COMPLIANT. REPLACE IF
POOR OR NON COMPLIANT
ROUTE CONDENSATE DRAIN AS DIRECTED BY
LANDLORD AND LOCAL CODE.
ROOF FLEXIBLE CONNECTION(S)
TOP UNIT SMOKE DETECTOR IN RA
DUCT PER LOCAL CODES
AIR DUCT
AIR DUCT
WHERE 'X' IS 12° OR LESS
EXTERIOR SUPPORTING
STRUCTURAL MEMBER MAY GI STRAP DUCT
BE OMITTED. TYP. HANGER 6'-0' O.C.
MAX RECTANGULAR
ROOFTOP
UNIT
SECTION
M1.0
SCALE NONE
EA HANGER
WHERE 'X' IS 12° OR LESS
EXTERIOR SUPPORTING
STRUCTURAL MEMBER MAY GI STRAP DUCT
BE OMITTED. TYP. HANGER 6'-0' O.C.
MAX RECTANGULAR
ROUND OR
MAX. LOAD
RANGER SIZE
DUCT DIMENSION
OVAL DUCT
EA HANGER
UP TO 16-
TO 9- DIA
72 LBS.
1-1/2' z 18 GA
16- TO 30'
9• TO 26' DIA.
160 LBS.
1-1/2' z 16 GA
(2) DUCTWORK BRACING
M1.0 SCALE: NONE
GENERAL NOTES:
1. CONTRACTOR IS REQUIRED TO FIELD—VERIFY EXISTING CONDITIONS PRIOR TO BID.
2. CONTRACTOR SHALL NOTIFY ARCHITECT AND ENGINEER IMMEDIATELY IF OBSTRUCTIONS EXIST.
3. PROVIDE TURNING VANES IN ALL 90 DEG ELBOWS IN SUPPLY AND RETURN DUCTWORK.
4. CONTRACTOR SHALL COORDINATE DUCTWORK DIAMETER PRIOR TO ORDERING DUCT MOUNTED REGISTERS.
5. CONTRACTOR SHALL LABEL ROOF EQUIPMENT WITH TENANTS NAME/SPACE NUMBER/UNIT TAG
PER SPECIFICATIONS.
6. FIRE PROTECTION CONTRACTOR SHALL PROVIDE MODIFICATIONS TO THE EXISTING FIRE SPRINKLER
SYSTEM AS REQUIRED TO PROVIDE CODE COMPLIANT COVERAGE FOR ALL AREAS. CONTRACTOR SHALL
PROVIDE SPRINKLER PLANS, CALCULATIONS AND COORDINATE FOR SUBMITTAL TO THE LOCAL AUTHORITIES.
NOTE:
PROVIDE GYP FINISH RINGS AT WALL PENETRATIONS UNLESS NOTED OTHERWISE
ALL DUCTWORK SHALL REMAIN UNPAINTED UNLESS NOTED OTHERWISE
—AIR SCOOP
ADJUSTMENT
CONTRACTOR SHALL INSTALL 4LSCREW
REGISTER IN ACCORDANCE WITH
MANUFACTURER'S INSTALLATION
INSTRUCTIONS. �r
CONTRACTOR SHALL VERIFY
SALES AREA SUPPLY DUCT
DIAMETER PRIOR TO ORDERING.
2 SALES AREA REGISTER DETAIL
M1.0 SCALE: NONE
NOTES:
OEXISTING LANDLORD ROOFTOP UNIT TO REMAIN SEE SCHEDULE ON THIS SHEET FOR ADDITIONAL INFORMATION. CONTRACTOR
SHALL VERIFY THAT UNIT IS IN WORKING CONDITION AND SHAM CLEAN AND REFURBISH THE UNIT SO R IS IN LIKE NEW
CONDITION. THIS INCLUDES BUT NOT LIMITED TO BELTS, COILS, FANS, BEARINGS, ETC. SEE SPECIFICATION FOR ADDITIONAL
INFORMATION.
O2 PROVIDE FULL SIZE RETURN AIR DUCT AS SHOWN ON PLANS. LINE RETURN AIR ELBOW WITH 1' ACOUSTICAL LINER.
CONTRACTOR SHALL PROVIDE A RETURN AIR OPENING GRILLE USING 1/2" WIRE MESH SCREEN. PROVIDE WITH 1" 26 GAUGE
STEEL FRAME.
OCONTRACTOR SHALL INSTALL NEW SUPPLY AIR SPIRAL DUCTWORK AS SHOWN ON PUNS. ALL DUCTWORK SHALL BE
UNPAINTED.
OCONTRACTOR SHALL FOLD VERIFY EXISTING DUCTWORK SIZES AND THAT EXISTING DUCTWORK IS SUITABLE FOR REUSE. IF
ANY DISCREPENCIES EXIST THE CONTRACTOR SHALL NOTIFY THE ENGINEER IMEDIATLY. IF ANY EXISTING DUCTWORK IS
SMALLER THAN THE SIZES SHOWN ON PLANS THE CONTRACTOR SHALL COORDINATE WITH THE ARCHTECT IN THE REPLACMENT
OF SUCH PEICES WITH NEW SPIRAL ROUND DUCTWORK SO AS TO MATCH OR EXEED THE SIZES OF THE DUCTWORK AS
SHOWN ON THE PLANS.
5BALANCING DAMPER TYPICAL
6 CONTRACTOR SHALL PROVIDE HONEYWELL VISION PRO SERIES 8220 THERMOSTAT WITH REMOTE SENSOR WHERE SHOWN ON
PUNS. MOUNT AT 48• A.F.F. OR AS DIRECTED BY OWNER OR ARCHITECT. COORDINATE INSTALLATION WITH OTHER TRADES TO
ENSURE NO OBSTRUCTIONS.
O7 THIS CONTRACTOR SHALL COORDINATE WITH ELECTRICAL CONTRACTOR WHO SHALL INSTALL REMOTE SENSOR WHERE SHOWN
ON PLANS MOUNT 48' A.F.F. COORDINATE WITH OTHER TRADES TO ENSURE NO OBSTRUCTIONS,
OCONTRACTOR SHALL VERIFY EXISTING TOILET EXHAUST FAN EF -1 IS IN GOOD OPERABLE CONDITION. CONTRACTOR SHALL
CLEAN SURFACE, REPAIR AND/OR REPLACE INTERIOR OPERATING COMPONENTS AS NEEDED. CONTRACTOR SHALL VERIFY
EXISTING RESTROOM EXHAUST DUCTWORK IS IN GOOD CONDITION AND FREE OF LEAKS. CONTRACTOR SHALL NOTIFY OWNER
OF FAN'S CONDITION PRIOR TO PERFORMING ANY WORK.
OELECTRICAL CONTRACTOR SHALL INSTALL IONIZATION TYPE DUCT SMOKE DETECTORS IN RETURN AIR DUCT OR AS REQUIRED
BY APPLICABLE CODES. MECHANICAL CONTRACTOR SHALL COORDINATE INSTALLATION.
10 CONTRACTOR SHALL PROVIDE A TRANSFER OPENING WHERE SHOWN ON PLANS. REFER TO SCHEDULE AND PLAN FOR EXACT
MODEL AND SIZE MOUNT GRILLES AS TIGHT TO DECK AS POSSIBLE COORDINATE WTIN OTHER TRADES PRIOR TO PERFORMING
ANY WORK.
11 CONTRACTOR SHALL PROVIDE GYP FINISH RING WHERE SHOWN ON PLANS AT DUCT WALL PENETRATION. COORDINATE WITH
OTHER TRADES TO ENSURE NO OBSTRUCTIONS PRIOR TO CONSTRUCTION.
iQFIRE SPRINKLER CONTRACTOR SHALL MODIFY EXISTING BUILDING SPRINKLER SYSTEM TO ACCOMMODATE NEW ARCHITECTURAL
SPACE LAYOUT. SALES AND STOCK ROOM AREAS ARE OPEN TO DECK. FIRE SPRINKLER CONTRACTOR SHALL PROVIDE
ADDITIONAL HEADS AS NEEDED FOR CODE COMPLIANT INSTALLATION.
13 CONTRACTOR SHALL DEMOLISH EXISTING DUCTWORK BACK TO WHERE NEW DUCTWORK WILL BE CONNECTED.
Alan,J.Plutowski
ARCHITECT
4125 Lakeland Ave. N., Suite 200
Minneapolis, Minnesota 55422
763-533-7171 fax: 763-533-7979
COIIBUItaIItB
RED WING SHOES
314 MAN soul* M ana NN ewes
m (mo) 7v Fix (asp smi
Certification
Project Information
RED WING SHOES
BUILD -OUT FOR
NEW DEALER
STORE
Red Ring Shoe all
9893 N. Indlacm Rd, ete 1207
(Y' IYY/ I IYYS I LYµ) (YY� I 9893 N. Iadiena 46032d,
Revisions
L-----
IA -14z 225 O O A-1428-2250 Date: 04/06/18
❑ r– Drawn By: MMS
2 BALANCE RETURN _-- II
TO 1825 CFM _ _ _ ----_ Checked By: 14x8 – __ MEA
i
0 L"111�
O – – --- A -14x8-150
/ 5 < g — ® Job Number: 16RYV-007
A -14x8-22 OO _
180 120
13 1
O 50 CFM
________________________
___ 1-4x8-150+1
14x8 – __ ________-Ac�4x8 �5TY______t______________Y____________
L– 12
Sheet Information
O O O O �2)C A,DID i.1Oe MECHANICAL PLAN
AND DETAILS
F_
RELEASED FOR CONSTRUCTION
Subject to compliance with all regulations
of State and Local Codes
City of Camel
DATE: 06/06/18
MECHANICAL PLAN
1/4" = 1'-0'
COPYRIGHT
2018
ALAN J.
PLUTOWSKI
M190