HomeMy WebLinkAboutM13.0RELEASED FOR CONSTRUCTION Subject to compliance with all regulations of State and Local Codes City of Camel DATE: 06/06/18 GENERAL PROVISIONS A. THE TERMS DEFINED BELOW APPLY TO ALL WORK INCLUDED IN THE CONTRACT DOCUMENTS. 1. THE TERM 'WORK' MEANS THE CONSTRUCTION AND SERVICES REQUIRED BY THE CONTRACT DOCUMENTS AND INCLUDES ALL OTHER LABOR, MATERIALS, EQUIPMENT AND SERVICES PROVIDED OR TO BE PROVIDED BY THE CONTRACTOR TO FULFILL THE MECHANICAL SUBCONTRACTOR'S OBUGARONS. 2. FURNISH — TO OBTAIN IN NEW CONDITION READY FOR INSTALLATION INTO THE WORK. 3. INSTALL — TO STORE, SE IN PLACE, CONNECT AND PUCE INTO OPERATION INTO THE WORK. 4. PROVIDE — TO FURNISH AND INSTALL 5. CONNECT — TO BRING SERVICE TO THE EQUIPMENT AND MAKE FINAL ATTACHMENT INCLUDING NECESSARY SWITCHES, OUTLETS, BOXES, TERMINATIONS, EC. 6. CONDUIT — INCLUDES IN ADDITION TO CONDUIT, ALL FITTINGS, PULL BOXES, HANGERS AND OTHER SUPPORTS AND ACCESSORIES RELATED TO SUCH CONDUIT. 7. CONCEALED — HIDDEN FROM SIGHT IN CHASES, FURRED SPACES, SHAFTS, HUNG CEILINGS, EMBEDDED IN CONSTRUCTION, IN CRAWL SPACES OR BURIED. S. EXPOSED — NOT INSTALLED UNDERGROUND NOR CONCEALED AS DEFINED ABOVE. B. THE GENERAL CONDITIONS, SPECIAL CONDITIONS, SUPPLEMENTARY CONDITIONS, AND MECHANICAL SPECIFICATIONS OF THE MAIN MALL SPECIFICATIONS AND "GENERAL CONDITIONS OF THE CONTRACT", CURRENT EDITION, ESTABLISHED IN STANDARD FORM BY THE AMERICAN INSTITUTE OF ARCHITECTS SHALL APPLY TO ALL WORK ON THIS PROJECT EXCEPT AS MODIFIED BELOW. COORDINATE THE MECHANICAL WORK WITH OTHER TRADES AND TENANT PRIOR TO INSTALLATION. C. THE ARCHITECTURAL ELECTRICAL AND FIRE PROTECTION PIANS AND SPECIFICATIONS ARE A PART OF THE CONTRACT DOCUMENTS. THE MECHANICAL CONTRACTOR SHALL VISIT THE SITE AND BECOME FAMILLMIZED WITH ALL CONDITIONS SURROUNDING THE WORK. IF ANY OF THE CONDRIONS REQUIRE A MODIFICATION OF THE SYSTEMS INDICATED BY THESE PLANS AND SPECIFICATIONS, ADVISE THE ENGINEER OF THE REQUIRED MODIFICATIONS AND IF APPROVED BY THE ENGINEER, INCLUDE THE COST OF SUCH MODIFICATIONS IN HIS BID. D. THROUGHOUT THE COURSE OF THE WORK, MINOR CHANGES AND ADJUSTMENTS TO THE PLIAS AND SPECIFICATIONS MAY BE REQUESTED BY THE TENANT. MAKE SUCH ADJUSTMENTS WITHOUT ADDITIONAL COST TO THE TENANT, WHERE SUCH ADJUSTMENTS ME NECESSARY FOR THE PROPER INSTALLATION AND OPERATION OF THE SYSTEMS, AND WITHIN THE INTENT OF THE CONTRACT DOCUMENTS. E. R IS THE INTENT OF THE PLANS AND SPECIFICATIONS TO PROVIDE INFORMATION FOR A COMPLETE INSTALLATION. EVERYTHING NECESSARY FOR THE COMPLETION AND SUCCESSFUL OPERATION OF THE WORK, WHETHER OR NOT HEREIN DEFINITELY SPECIFIED OR INDICATED ON THE DRAWINGS, SHALL BE FURNISHED AND INSTALLED AS WELL AND AS FAITHFULLY AS IF SO SPECIFIED OR INDICATED WITHOUT ADDITIONAL COST TO THE TENANT. THE MECHANICAL CONTRACTOR SHALL VERIFY ALL DIMENSIONS AND LENGTHS PRIOR TO INSTALLATION. F. NOTWTHSIANDING ANY OTHER PROVISIONS OF THE CONTRACT DOCUMENTS. THE MECHANICAL CONTACTOR BEARS ULTIMATE RESPONSIBILITY FOR COMPLIANCE OF THE INSTALLATION WITH THE REQUIREMENTS OF THE LANDLORD AND OF THE LOCAL AUTHORITY HAVING JURISDICTION. G. IF ANY ERRORS, DISCREPANCIES OR OMISSIONS APPEAR IN THE DRAWINGS, SPECIFICATIONS OR OTHER CONTRACT DOCUMENTS, THE MECHANICAL CONTRACTOR SHALL NOTIFY THE ENGINEER IN WRITING OF SUCH ERROR OR OMISSION. IN THE EVENT THIS CONTRACTOR FAILS TO GIVE SUCH NOTICE BEFORE CONSTRUCTION AND/OR FABRICATION OF THE WORK, HE WILL BE HELD RESPONSIBLE FOR THE RESULTS OF ANY SUCH ERRORS, DISCREPANCIES OR OMISSIONS AND THE COST OF RECTIFYING SAME. H. COMPLY WITH THE REQUIREMENTS OF ALL STATE AND LOCAL CODES REGULATING THIS WORK. I. PAY ALL FEES AND RELATED CHARGES FOR PERMITS. LICENSES, ETC., REQUIRED FOR INSTALLATION OF THE MECHANICAL SYSTEM. J. REIMBURSE THE ELEC70CAL CONTACTOR, WITHOUT ANY COST TO TENANT OR LANDLORD, ANY ADDITIONAL EXPENSES THE ELECTRICAL CONTRACTOR INCURS DUE TO THE MECHANICAL CONTRACTOR'S SUBSTITUTION OF MECHANICAL EQUIPMENT HAVING DIFFERENT ELECTRICAL SERVICE REQUIREMENTS THAN THE SCHEDULED EQUIPMENT. K. PROVIDE THE ARCHITECT AND/OR OWNER WITH A MINIMUM OF FIVE CERTIFIED COPIES OF ALL SHOP AND EQUIPMENT DRAWINGS FOR HIS APPROVAL, TWO OF WHICH SHAT BE RETAINED BY THE ARCHITECT. AND THE REMAINING BEING RETURNED TO THE GENERAL CONTRACTOR. DRAWINGS SHALL BE SUBMITTED BEFORE START OF CONSTRUCTION. FAILURE OF COMPLIANCE WITH THIS PARAGRAPH WILL RESULT IN WITHHOLDING OF FINAL PAYMENT. L PROVIDE A WRITTEN WARRANTY THAT THE ENTRE INSTALLATION IS FREE FROM DEFECTS IN MATERIALS AND WORKMANSHIP FOR A PERIOD OF ONE YEAR, EXCEPT THAT AR CONDITIONING COMPRESSORS SHALL BE WARRANTED FOR FIVE (5) YEARS AND GAS FIRED HEAT EXCHANGERS SHALL BE WARRANTED FOR TEN (10) YEARS. M. ALL WORKMANSHIP AND MATERIALS SHALL MEET OR EXCEED THE INDUSTRY FOR QUALITY IN EVERY RESPECT. ALL MATERIALS AND EQUIPMENT SHALL BE NEW, OF THE LATEST DESIGN AND FREE OF DEFECTS. N. DESIGN ALL PIPING AND DUCTWORK TO PRESENT A NEAT AND ORDERLY APPEARANCE. RUN ALL LINES PARALLEL WITH BUILDING WALLS AND CONSTRUCTION. KEEP PIPING AND DUCTWORK FREE FROM CONTACT WITH STRUCTURE OR EQUIPMENT TO PREVENT NOISE TRANSMISSION. ALLOWING CLEARANCE FOR EXPANSION AND CONTRACTION. PROVIDE ACCESS DOORS OR PANELS FOR ALL VALVES, CLFANOUTS, DAMPERS, CONTROLS, DEVICES, ETC. 0. PROVIDE VIBRATION ISOLATION DEVICES FOR Al MOVING MACHINERY. PROVIDE FLEXIBLE CONNECTIONS TO ALL MOVING MACHINERY. P. ALL WELDING SHALL BE PERFORMED IN ACCORDANCE WITH THE NATIONAL CERTIFIED PIPE WELDING BUREAU, LOCAL CODES OR OTHER APPROVED PROCEDURE CONFORMING TO THE ASME CODE FOR PRESSURE PIPING. O FURNISH Al MATERIALS AND LABOR FOR COMPLETE AND FULL OPERATION OF THE ENCOMPASSED SYSTEMS. R. BEFORE BIDS ME RECEIVED, INFORM THE OWNER OF PERCEIVED OMISSIONS. ISSUES IN THE SPECIFICATIONS OR ISSUES ON THE PLANS. OTHERWISE, THE ABOVE DOCUMENTS WILL BE CONSIDERED SUFFICIENT NOTIFICATION TO PROVIDE MATERIAL AND LABOR FOR A COMPLETE AND OPERATIONAL SYSTEM. DUCTWORK A THE AR DISTRIBUTION SYSTEM SHALL BE FABRICATED M RECOMMENDED IN THE LATEST EDITION OF THE SMACNA LOW VELOCITY DUCTWORK MANUAL AND INSTALLED WHERE SHOWN ON HVAC PUN. FURNISH ALL REQUIRED DAMPERS, TRANSITIONS, AND CONNECTIONS TO AR TERMINALS NECESSARY FOR A COMPLETE OPERATING SYSTEM. B. FABRICATE AND INSTALL AS RECOMMENDED IN LATEST EDITION OF SMACNA HVAC DUCTWORK CONSTRUCTION STANDARDS — MEM AND FLEXIBLE AND THE ASHRAE GUIDE AND DATA BOOK FOR SHEET MEAL DUCTWORK SERVING SUPPLY, RETURN AND EXHAUST SYSTEMS OPERATING BETWEEN —2.0 IN. W.G. AND +2.0 IN. W.G. MAXIMUM PRESSURE. INSTAL WHERE SHOWN ON THE PLAINS. DUCT SIZES SHOWN ON THE PUNS ME INTERIOR CLEAR DIMENSIONS. WHERE INTERNAL INSULATION IS PROVIDED, DUCT SIZES SHALL BE INCREASED AS REQUIRED TO MAINTAIN THE INDICATED INTERIOR CLEAR DIMENSIONS. PROVIDE DUCTWORK IN ACCORDANCE WITH INDUSTRY STANDARDS FOR ACHIEVING AIR TIGHT 5 PERCENT LEAKAGE AND NOISELESS (NO OBJECTIONABLE NOISE) SYSTEMS, CAPABLE OF PERFORMING EACH INDICATED SERVICE. C. FABRICATE DUCTWORK FROM GALVANIZED SHEET STEEL COMPLYING WITH ANSI/ASTM, SMACNk INDUSTRY STANDARDS AND LOCAL CODE REQUIREMENTS. MINIMUM SHEET THICKNESS AND REINFORCING SHALL BE AS FOLLOWS: 1. DUCTS UP TO 12" WIDEST DIMENSION (OR DIAMETER): 26 GAUGE 2. DUCTS 13" TO 30" WIDEST DIMENSION: 24 GAUGE 3. DUCTS 31" TO 54" WIDEST DIMENSION: 22 GAUGE D. DUCT SEALANT: UNITED DUCT SEALER OR EQUAL PROVIDE A NON—HARDENING, NON—MIGRATNG MASTIC OR UOUID ELASTIC SEALANT OF A TYPE AS RECOMMENDED BY THE MANUFACTURER SPECIFICALLY FOR SEANNG JOINTS AND SEAMS IN SHEET MEM DUCTWORK. ALL DUCTWORK SHALL HAVE SEALED LONGITUDINAL AND TRANSVERSE JOINTS. WHERE SUP AND DRIVE JOINTS ARE WE. A SEALER SR41L BE APPLIED OVER THE ENTIRE JOINT AFTER THE DRIVE IS IN PUCE APPLY A SECONDARY LAYER OF SEALER AT THE CORNERS AFTER THE DRIVE ENDS ARE CRIMPED IN PLACE. ALL LONGITUDINAL SEAMS SHALL BE COVERED WITH A SEALING MASTIC. ALL SUP JOINTS SHALL BE MADE AND COATED, THEN INSERTED INTO THE DUCT OR COLLAR AND SECURED WITH SHEET METAL SCREWS. COVER THE ENTIRE OUTER JOIN" AND SCREWS WITH MASTIC. COVER JOINTS AROUND ALL SPIN—IN FITTINGS. INTERNALLY CLEAN DUCTWORK OF OUST AND DEBRIS. E SUPPORT MATERIALS: EXCEPT AS OTHERWISE INDICATED, PROVIDE HOT—DIPPED GALVANIZED SHEET FASTENERS, ANCHORS, RODS, STOPS, TRIM, AND ANGLES FOR SUPPORT OF DUCTWORK. F. ANY SUPPLY DUCTWORK AND PLENUMS THAT ARE DESIGNED TO OPERATE AT STATIC PRESSURES GREATER THAN 0.25" WG BUT LESS THAN 2" WG, WHICH ME LOCATED OUTSIDE OF THE CONDITIONED SPACE OR IN RETURN PLENUMS, SHALL HAVE JOINTS SEALED IN ACCORDANCE WITH SEM CUSS AS DEFINED IN THE Sell HVAC DUCT LEAKAGE TEST MANUAL PRESSURE SENSITIVE TAPE SHALL NOT BE USED AS THE PRIMARY SEALANT WHERE SUCH DUCTS ME DESIGNED TO OPERATE AT STATIC PRESSURES OVER 1" W.G. DUCTWORK ACCESSORIES A BALANCING DAMPERS: AR BALANCE, INC., LOUVERS @ DAMPERS, INC., GREENHECK, RUSKIN, OR EQUAL PROVIDE MANUAL. SINGLE OR MULTIBLADE DAMPERS, AS INDICATED AND AS CONSTRUCTED IN ACCORDANCE WITH SMACNA STANDARDS. B. DAMPERS SHALL HAVE RIGID 2" X 1/2" X10—GAUGE CHANNEL FRAMES, HALL OR BRONZE SLEEVE BEARINGS, 1/2" POLISHED STEEL AXLES, 16—GAUGE, REINFORCED, FELT—EDGED BLADES (NOT OVER 8" WIDE) AND STOP FRAMES MOUND THE ENTIRE PERIMETER. VOLUME DAMPERS IN DUCTS LARGER 12" X 6" SHALL BE THE OPPOSED BLADE TYPE. DAMPERS IN ROUND DUCTS AND DUCTS 12" X 6" AND SMALLER SHALL BE BUTTERFLY TYPE ROUND BUTTERFLY TYPE VOLUME DAMPERS SHALL BE 26—GAUGE STEEL THROUGH 12" DIAMETER, 24—GAUGE FOR ABOVE 120 . C. PROVIDE VENTFMRICS. YOUNG REGULATOR, OR EQUAL DAMPERS. ALL DAMPERS SHALL BE EQUIPPED WITH STANDARD OUMDR NTS OF SUITABLE SIZE IN EQUIPMENT ROOMS/BACK OF HOUSE ARES. PROVIDE YOUNG REGULATOR MODEL J 301A. OR EQUAL, RECESSED—TYPE IN FINISHED MEAS. PROVIDE QUADRANT LOCKING DEVICE FOR EACH DAMPER ON ONE END OF THE SHAFT AND AN END BEARING EXTENDED QUADRANT LOCKED AND EXTENDED BEARING PLATES FOR EXTERNALLY INSULATED DUCTWORK. D. VOLUME DAMPERS SHALL BE PROVIDED IN ALL DUCTS TO PERMIT ACCURATE BALANCING OF THE SYSTEM. THE DAMPERS SHALL BE ADJUSTED TO SATISFY THE HEATING, COOLING AND VENTILATING REQUIREMENTS OF THE CONDITIONED SPACE AND LOCKED IN PLACE. E. MOTORIZED DAMPERS: FURNISH AND INSTAL ALL MOTORIZED DAMPERS SHOWN ON THE PUNS AND REQUIRED FOR SYSTEM OPERATION AND AS DESCRIBED IN THIS SECRON AND NOT BEING FURNISHED WITH EQUIPMENT. DAMPERS SHALL BE OPPOSED BLADE WITH NEOPRENE EDGES AND SHALL NOT BE LESS THAN 13 GAUGE GALVANIZED STEEL FORMED FOR EXTRA STRENGTH WITH MOUNTING HOLES FOR ENCLOSED DUCT MOUNTING. GRILLES. REGISTERS AND DIFFUSERS A FURNISH AND INSTALL TITUS, KRUEGER, PRICE, ANDAOSTAT OR EQUAL AS SCHEDULED. OPPOSED BLADE VOLUME DAMPERS FOR REGISTERS SHALL BE TINS SERIES AG -35, KRUEGER SERIES OBC, OR EQUAL. FOR OPPOSED BLADE TYPES WITH VERITCAL BLADES AND SCREWDRIVER SLOTS OR ALLEN WRENCH ADJUSTMENT ACCESSIBLE THROUGH THE REGISTER. IT SHALL BE THIS CONTRACTOR'S RESPONSIBILITY TO PROVIDE MISCELLANEOUS ITEMS AS NECESSARY FOR A COMPLETE AND PROPER INSTALUTON IN THE TYPES OF WALLS, AND CEILINGS USED ON THIS PROJECT. THIS SHAT INCLUDE SUCH ITEMS AS FASTENERS, PLASTER RINGS, AND SUPPORTS, EIC. B. DUCT PLASTER RINGS AT ALL WALL PENETRATIONS SHALL BE PRICE INDUSTRIES 0DIFF, OR OR PR IN AN APPROPRIATE SIZE TO MATCH DUCT. FINISH TO MATCH WALL OR DUCT. CONNECTIONS A ALL SQUARE ELBOWS SHALL HAVE TINS, KRUEGER OR STREAMLINED TURNING VANES. B. ALL BRANCH TAKEOFF DUCTS SHALL BE OF THE PROPORTIONAL TYPE UNLESS SPECIFICALLY SHOWN OTHERWISE. VOLUME DAMPERS ME REQUIRE! ON ALL TAKE—OFFS. C. ALL OPENINGS IN DUCT FOR GRILLES, REGISTERS, ETC, SHALL BE CAPPED DUST TIGHT WITH G.I. MEAL CAPS DURING THE CONSTRUCTION PERIOD. D. ROUND BRANCH DUCT CONNECITONS TO RECTANGULAR MANS SHALL BE MADE WITH SPIN—IN—CONICAL TAKEOFF WITH INTEGRAL VOLUME DAMPER AND QUADRANT OPERATOR AND EXTRACTOR AIR SCOOP. E. WHERE DUCTS RUN THROUGH BAR JOISTS OR OTHER CEILING SPACES AND STRUCTURAL, MECHANICAL OR ELECTRICAL INTERFERENCE IS ENCOUNTERED, SHEET MEAL WORKER SHALL MODIFY DUCTWORK TO MAINTAIN SAME CROSS—SECTOWL AREA AS INDICATED ON THE PIANS WITH A MAXIMUM OF 5 TO 1 ASPECT RATIO. FIEXIBLE CONNECTIONS A PROVIDE VENTFMRICS, INC., DURO DYNE. OR EQUAL PROVIDE FLEXIBLE DUCT CONNECTIONS WHEREVER DUCTWORK CONNECTS TO VIBRATION ISOLATED EQUIPMENT AND WHERE SHOWN OR NOTED. MAKE AIRTIGHT JOINTS. PROVIDE ADEQUATE JOINTS. ACCESS PANELS A PROVIDE ACCESS PANELS AT ALL REHEAT COILS, FIRE DAMPERS, MOTORIZED VOLUME DAMPERS, CONTROL EQUIPMENT, ELBOWS ON DUCT MANS WITH TURNING VANES OR ORDER EQUIPMENT REQUIRING MAINTENANCE TO PERMIT EASY ACCESS FOR INSPECTIONS AND MANTDMCE PANELS SHALL BE LOCATED ON BOTTOM OR SIDES OF DUCT SUCH THAT MAINTENANCE CAN BE PERFORMED. PANELS SHALL BE SE IN RIGID FRAME WITH CLOSED—CELL SOFT GASKET, DOUBLE WALL INSULATED AND COMPLETE WITH TWO UTCHES FOR DOORS UP TO 18"X18" AND FOUR LATCHES FOR LARGER DOORS. INSTALLATION A PROVIDE DUCTWORK IN CONFORMANCE TO LATEST ADDITION OF SIAM STANDARDS. B. ALL DUCTWORK SHALL BE RUN SUBSIANTALLY AS SHOWN ON THE DRAWINGS WITH BENDS AND CURVES IN COMPLIANCE WITH LATEST EDITION OF SMACNA STANDARDS. IN NO CASE SHALL THE INSIDE RADIUS BE LESS THAN THE WIDTH OF THE DUO EXCEPT WHERE DUCT TURNING VANES ME USED. CHANGES IN SIZE OR CROSS SECTION SALOL BE MADE WITH LONG TAPERS. THE ENGINEER RESERVES THE RIGHT TO SLIGHTLY CHANGE THE RUN OF CERTAIN DUCTS WITHOUT EXTRA COST TO THE OWNER IF NECESSARY TO AVOID UNFORESEEN STRUCTURAL OR OTHER INTERFERENCES. C. BEFORE FMRICATNG ANY DUCTWORK, TAKE ACCURATE MEASUREMENTS ON THE JOBSTIE TO INSURE PROPER CLEARANCES. D. PROVIDE SPIN—IN FITTINGS WITH DAMPERS AT DUCT TAKE—OFFS TO DIFFUSERS. E. FLEXIBLE DUCT ON BRANCH ENDS SHALL BE A MAXIMUM OF 5'-0" IN LENGTH, WITH A VOLUME DAMPER MOUNTED AT THE NECK OF THE DIFFUSER. THE VOLUME DAMPER LEVER SHALL HAVE A RED TAG INSTALLED, CLEARLY VISIBLE FROM SIDES OF DIFFUSERS ABOVE CEIUNG. THE FLEXIBLE DUCT SHALL BE CONNECTED AT BOTH ENDS WITH STAINLESS SCREW TYPE HOSE CLAMPS. CONDENSATE PIPING A CONDENSATE PIPING FROM COOLING GOIL AND MOISTURE FROM FLUE GASES SHALL BE FURNISHED AND INSTALLED BY THE MECHANICAL CONTRACTOR. PROVIDE WATER TRAP AT EACH GOIL AND FLUE DRAIN. RUN BOTH SYSTEMS SEPARATELY TO NEAREST FLOOR DRAIN OR RECEPTOR APPROVED BY AUTHORITY HAVING JURISDICTION. INSULATION A INSULATION SHALL BE REQUIRED ON ALL SURFACES TO RETARD UNDESIRABLE HEAT TRANSFER AND PREVENT CONDENSATION. INSULATION SHALL BE APPLIED TO PIPE LINES, DUCTWORK AND EQUIPMENT ONLY AFTER THEY HAVE BEEN TESTED, INSPECTED AND ALL SURFACES THOROUGHLY CLEANED OF ALL MOISTURE, FOREIGN MATERIAL, GREASE AND RUST. INSULATION SHALL BE CONTINUOUS THROUGH WALLS, PARTITIONS, SLEEVES, EC., EXCEPT WHERE OTHERWISE INDICATED OR SPECIFIED. ALL INSULATION ADHESIVES, SEALERS AND COATINGS SHALL HAVE A FIRE HAZARD RATING NOT TO EXCEED 25/50/50 FLAME SPREAD, FUEL CONTRIBUTED AND SMOKE DEVELOPED IN ACCORDANCE WITH UL 723 AND ASIM—E84. PROVIDE INSULATION FOR HOT AND COLD WATER PIPING, HORIZONTAL WASTE PIPING IN CEIUNG SPACE, SUPPLY ALR, RETURN AR, EXHAUST AR AND OUTSIDE AR SHOE MEAL DUCTWORK. B. WHERE NOTED ON THE DRAWINGS, ALL NEW SUPPLY AND RETURN DUCTWORK SHALL BE INSULATED WITH EXTERNA DUCT WWW. DUCT WRAP SHALL BE FOIL REINFORCED KRAFT FACING. All INSULATION SHALL MEET NAPA 90A FLUME SPREAD UNDER 25 AND SMOKE DEVELOPED UNER 50. THICKNESS, DENSITY AND "R" VALUE SHALL BE PER LOCAL ENERGY CODE INSULATION SHALL BE FASTENED TO DUCTWORK PER MANUFACTURER'S INSTALLATION INSTRUCTIONS AND Sell STANDARDS. ROUND BRANCH DUCTWORK SHALL BE INSULATED WITH MINIMUM 1" THICK FIBERGLASS SLEEVE WITH FOIL JACKET AND ALL JOINTS AND TERMINATIONS SEALED WITH FOIL DUCT TAPE EXPOSED DUCTWORK IN THE CONDITIONED SPACE DOES NOT NEED TO BE INSULATED. C. INSULATED FLEXIBLE DUCT SHALL BE GENERAL ENVIRONMENTAL CORPORATION ME G30A. OR EQUAL FLEXIBLE DUCT RUNS SHALL BE UMITED TO A MAXIMUM LENGTH OF 5'-0'. D. RETURN DUCT IN ATTIC SPACES SHALL BE INSULATED PER THE REQUIREMENTS OF SUPPLY DUCTWORK NOTED ABOVE. E. ROUND BRANCH DUCTWORK SHALL BE INSULATED WITH MINIMUM 1- THICK FIBERGLASS SLEEVE WITH FOIL JACKET AND ALL JOINTS AND TERMINATIONS SEALED WITH FOIL DUCT TME. EXPOSED DUCTWORK IN THE CONDITIONED SPACE DOES NOT NEED TO BE INSULATED. F. EXCEPTION: IN ACCORDANCE WITH THE ENERGY CODE INSULATION IS NOT REQUIRED WHERE THE DESIGN TEMPERATURE DIFFERENCE BETWEEN THE INTERIOR AND THE EXTERIOR OF THE DUCT OR PLENUM IS NOT GREATER THAN 15' F. G. IF A SPLIT SYSTEM IS USED SUCTION UNFS SHALL BE INSULATED WITH 1" THICK FOAM TYPE PIPE INSULATION, M ARMAFLE(, OR APPROVED EQUAL. WHEREVER POSSIBLE, INSULATION SHALL BE SUPPED OVER LENGTHS OF PIPING BEFORE FINAL FABRICATION WITHOUT SUITING THE INSULATION. FIRE/SMOKE DAMPERS A GALVANIZED STEEL CURTAIN TYPE WITH INTERLOCKING BLADES, STAINLESS STEEL CLOSURE SPRINGS AND LATCHES FOR HORIZONTAL INSTALLATION, BLADES OUT OF AR STREAM, FUSIBLE LINKS, UL LISTED 33. B. ACCEPTABLE MANUFACTURERS: GREENHECK, LOWERS & DAMPERS, RUSKIN OR EQUAL EOUIPMENT — SCOPE A UNLESS OTHERWISE NOTED, FURNISH ALL LABOR, MATERIALS AND EQUIPMENT FOR THE INSTALLATION OF A COMPLETE AND TENANT ACCEPTABLE OPERATING HEATING AND AIR CONDITIONING SYSTEM HEREIN DESCRIBED, AND AS SHOWN ON PUNS. THE SPACE IN GENERA SHALL BE HEATED AND COOLED BY MEANS OF AN EXISTING PACKAGED ROOFTOP AR CONDITIONING UNIT. SPACE TEMPERATURE CONTROL REQUIREMENTS A PROVIDE UNLESS NOTED OTHERWISE, ALL ELECTRIC WIRING, THERMOSTATS, SENSORS, CONTROLLERS, RELAYS, CONTACTORS, DAMPERS, ACRM70RS AND ALL OTHER MATERIALS NECESSARY FOR A COMPLETE AND PROPERLY INSTALLED OPERATING TEMPERATURE CONTROL SYSTEM THAT IS COMPATIBLE WIRD THE INSTALLED EQUIPMENT AND ALL LANDLORD REQUIREMENTS, INCLUDING EMERGENCY SHUTDOWN OF HVAC EQUIPMENT, UNLESS OTHERWISE NOTED. B. PROVIDE NEW ELECTRONIC 7—DAY PROGRAMMABLE THERMOSTAT OF COMPATIBLE MANUFACTURER AS THE HVAC UNIT AT LOCATIONS SHOWN ON PUMA. VERIFY THAT ALL TEMPERATURE CONTROL SEQUENCES ME OPERATING PROPERLY AND TO THE INSTALLATION REQUIREMENTS OF THE HVAC UNIT MANUFACTURER. UNLESS NOTED OTHERWISE, OR AS DIRECTED BY TENANT, PROGRAM TO THE FOLLOWING SETPOINTS: OCCUPIED HEAT — 70F OCCUPIED COOL — 751 HEATING NIGHT SETBACK — 60F COOLING NIGHT SET BACK — 85'F SEQUENCE OF OPERATION A OCCUPIED HOURS: SUPPLY FAN SHALL OPERATE CONTINUOUSLY, AND THE OUTSIDE MR DAMPER SHALL OPEN TO THE MINIMUM POSITION. COOLING OR HEATING SHALL CYCLE TO MAINTAIN SPACE TEMPERATURE SE POINT. B. UNOCCUPIED HOURS: OUTSIDE AR DAMPER SHALL BE CLOSED. SUPPLY FAN AND CONDENSING UNIT/SECRON OR GAS HEATING SHALL CYCLE TO MAINTAIN SPACE TEMPERATURE SEFPOINT. C. ECONOMIZER MODE: DRY—BULB CONTROLLED ECONOMIZER SHAT ACTIVATE WHENEVER THE OUTSIDE AR DRY—BULB IS LOWER THAN THE DRY—BULB CONTROL SETING. ECONOMIZER DAMPERS SHALL MODULATE TO FULL OPEN POSITION, AS REQUIRED, TO MAINTAIN DISCHARGE AR TEMPERATURE BETWEEN 52 AND 58 DEGREES FAHRENHEIT. MECHANICAL COOUNG/HEATING SHALL BE LOCKED OUT OF ECONOMIZER MODE. WHEN THE SPACE TEMPERATURE SETPOINT IS SATISFIED. THE DAMPER SHALL RETURN TO THE MINIMUM OLUSIDE AR POSITION DURING OCCUPIED All AND CLOSE COMPLETELY DURING UNOCCUPIED MODE. D. SMOKE ALARM MODE UPON A SIGNAL FROM THE DUCT SMOKE DEFECTOR AND THE HVAC UNIT SHALL SHUT DOWN, AND THE OUTSIDE AR DAMPER SHALL CLOSE. BAIANCING AIR AND WATER SYSTEMS A. WHEN THE WORK HAS BEEN COMPLETED, WITTY THE GENERAL CONTRACTOR, WHO SHALL HIRE A BALANCING CONTRACTOR. THE SYSTEM BALANCING SHALL BE BY AN INDEPENDENT TRADE LICENSED BY THE ASSOCIATED AIR BALANCING COUNCIL (AABC) OR THE NATIONAL ENVIRONMENTAL BALANCING BUREAU (NEED) TO TEST. ADJUST AND BALANCE ALL SPACE CONDITIONING AND VENTILATION SYSTEMS. Al BALANCING WORK SHALL BE COMPLETED AND DONE IN ACCORDANCE WITH THE MOST RECENT STANDARDS OF THEIR SOCIETY. ALL COSTS FOR TESTING AND BOUNCING SHALL BE INCLUDED IN THE BID. THE MECHANICAL CONTRACTOR SHALL PROVIDE FINAL OR AND WATER BALANCE INSPECTION AND REPORT TO THE LANDLORD, TENANT, ENGINEER, AND THE GENERAL CONTRACTOR. START UP OF SYSTEMS. GUARANTEE AND INSrRUcnONS A GUARANTEE AND MAINTAIN THE STABILITY OF ALL WORK AND MATERIALS FOR A PERIOD OF ONE (1) YEAR AFTER THE FINAL PAYMENT FOR COMPLETION OF THE WORK AS VERIFIED BY FINAL INSPECTION OF TENANT'S ARCHITECT. DEFECTS OF ANY KIND DUE TO FAULTY WORK OR MATERIALS APPEARING DURING THE ABOVE—MENTIONED PERIOD MUST BE IMMEDIATELY CORRECTED BY THIS MECHANICAL CONTRACTOR AT HIS OWN EXPENSE TO THE ENTIRE SATISFACTION OF TENANTS ARCHITECT AND ENGINEERS. SUCH REPAIRS AND RECONSTRUCTION SHALL INCLUDE AL1 DAMAGE TO THE FINISH OR FURNISHINGS OF THE BUILDING RESULTING FROM THE ORIGINAL DEFECT OR REPAIRS THERETO. OWNERS DESIGNATED OPERATING PERSONNEL SHALL BE FULLY INSTRUCTED BY THE MECHANICAL CONTRACTOR IN THE OPERATION OF EACH MECHANICAL SYSTEM AT THE TIME R IS PUT INTO SERVICE. ASSEMBLE AND DELIVER TO TENANT BEFORE FINAL PAYMENT IS MADE FOUR (4) 3—RING BINDER COMBINED SETS OF SHOP DRAWINGS. MANUFACTURER'S BULLETINS OR OTHER DATA AS REQUIRED COVERING THE CARE, MANIENANCE, AND OPERATION OF EACH PIECE OF EQUIPMENT FURNISHED AND/OR REFURBISHED, AND DELIVER TWO (2) BINDERS TO THE GENERAL CONTRACTOR AND TWO (2) BINDERS TO THE OWNER. PLUMBING A SUPPORT HORIZONTAL PIPING ADEQUATELY FROM SLABS OR OTHER STRUCTURAL MEMBERS AT INTERVALS SPECIFIED BELOW. USE GRINNELL /260 HANGERS, OR EOUA. HAVING ADJUSTABLE WROUGHT CLEVS, SOUD RODS AND SOCKETS. PIPING INSTALLED ALONG WALLS SHALL BE SUPPORTED BY GRINNELL /199, OR APPROVED EQUAL STEL ANGLE BRACKETS. THE SPACING OF PIPE SUPPORTS FOR STEEL PIPE 0" TO 2" SHALL BE 10'-0" FOR COPPER PIPE SIZE UP TO 2" SHALL BE 6'-0". HANGERS IN CONTACT WITH COPPER SHALL BE COPPER PLATED AND SHALL BE GRINNELL FIG. CT -65 OR APPROVED EOUAL HANGERS RODS SHALL BE 1" DIAMETER FOR PIPES UP TO 2" IN SIZE. PROVIDE 16 GAUGE, GALVANIZED STEEL PIPE SUPPORT SHIELDS, AT ALL PIPE HANGERS. B. CUT ALL OPENINGS IN FLOORS AND WALLS REQUIRED FOR PENETRATION OF PIPING. COORDINATE OPENINGS WITH GENERAL CONTRACTOR, WHO SHALL PERFORM ALL PATCHING AS REQUIRED BY ARCHIE DURAL SPECIFICATIONS. ALL HORIZONTAL PIPING WHICH PENETRATES WALLS SHALL BE ITTTED WITH PIPE SLEEVES MADE UP OF STANDARD STEEL PIPE 1" GREATER IN DIAMETER MAN OUTSIDE DIAMETER OF PIPE AND PIPE INSULATION. C. THE VOID BETWEEN PIPE AND SLEEVE SHALL BE SEALED WITH ROPE AND FILLED WITH EXPANDABLE (NON—SHRINKING) CEMENT. SLEEVES SHALL BE OF SUCH LENGTH THAT THEY END FLUSH WITH WALL FINISH ON BOTH SIDES OF WALL WHERE UNCOVERED EXPOSED PIPES PASS THROUGH WALLS THE SHALL BE FITTED WITH CRANE /10. OR EQUAL WALL PLATES. D. ALL PENETRATIONS THROUGH FIRE RATED MATERIALS SHALL BE SEALED AS NEEDED AND REQUIRED TO COMPLY WITH THE APPROPRIATE U.L REQUIREMENTS. E. ALL ABOVE GROUND WATER SUPPLY PIPE SHALL BE TYPE L HARD TEMPER COPPER WATER TUBE COMPLYING WITH ASTM BOB AND ANSV14SF STANDARD 61. ALL FITTINGS SHALL BE WROUGHT COPPER COMPLYING WITH USASI 876..16 k B16.18a. DIELECTRIC COUPLINGS SHALL BE USED BETWEEN STEEL AND COPPER CONNECTIONS. ALL BELOW GROUND WATER SUPPLY PIPE SHALL BE TYPE K SOFT TEMPER COPPER WATER TUBE. USE LEAD FREE SOLDER ON ALL JOINTS IN POTABLE WATER PIPING. F. IF PERMITTED BY LOCAL CODES AND THE LOCAL AUTHORITY HAVING JURISDICTION, THE CONTRACTOR MAY PROVIDE ABS OR BVC PIPING IN UEU OF CAST IRON FOR SANITARY WASTE AND VENT PIPING OR IN UEU OF COPPER PIPING FOR DOMESTIC WATER PIPING. CONTRACTOR SHALL VERIFY WITH OTHER TRADES PRIOR TO SUBSTIMION THAT THERE IS NO PLENUM RETURN ON THIS PROJECT. G. All ABOVE GROUND SANITARY WASTE AND VENT PIPING SHALL BE NO—HUB CAST IRON SANITARY SYSTEM COMPLYING WITH CISPI #301-69T. ALL BELOW GROUND SANITARY AND WASTE PIPING SR41L BE NO—HUB CAST IRON SANITARY SYSTEM COMPLYING WITH CISPI If301-69T OR SERVICE WEIGHT CAST IRON HUB AND SPIGOT WITH NEOPRENE GASKET COMPLYING WITH CISPI MIFISN-68I OR SCHEDULE 40 PVC BELOW GRADE OR AS REQUIRED FOR LANDLORD APPROVAL AND LOCAL CODE H. FURNISH AND INSTALL VALVES WHERE INDICATED ON PUN AND NECESSARY FOR PROPER SYSTEM OPERATION AND COMPONENT ISOLATION. PROVIDE VALVES RATED FOR 125 PSI OR GREATER WORKING PRESSURE IN WATER PIPING. CHECK VALVE UP TO 3". CRANE NO. 37, OR EQUAL GLOBE VALVE UP 70 3": CRANE NO. 1240, 1241, OR EQUAL GATE VALVE UP TO 3": CRANE 428, 1334, OR EQUAL BALL VALVE UP TO 3": APOLLO SERIES 70-100, OR EQUAL PRESS. REUEF VALVE: WATTS 10L MOD. M4, OR EQUAL Y.nM X Y."F SHOCKSTOP: WADE 110 (HOT), WADE }5 (COLD) BACKFLOW PREVENTER: WATTS NO. 009, OR EQUAL VACUUM REE VALVE: WATTS NO. 36A — x", OR EQUAL I. INSULATION SHALL BE REQUIRED ON ALL SURFACES TO REMD UNDESIRABLE HEAT TRANSFER AND PREVENT CONDENSATION. INSULATION SHALL BE APPLIED 70 PIPE LINES, AND EQUIPMENT ONLY AFTER THAT HAVE BEEN TESTED, INSPECTED AND ALL SURFACES THOROUGHLY CLEANED OF ALL MOISTURE. FOREIGN MATERIAL GREASE AND RUST. INSULATION SHALL BE CONTINUOUS THROUGH WALLS, FLOORS, PARTITIONS, SLEEVES, ETC., EXCEPT WHERE OTHERWISE INDICATED OR SPECIFIED. ALL INSULATION 25/50/50 FLAME SPREAD, FUEL CONTRIBUTED AND SMOKE DEVELOPED IN ACCORDANCE WITH UL 723 AND ASTM—E84. PROVIDE INSULATION FOR HOT AND COLD WATER PIPING, HORIZONTAL WASTE PIPING IN CEIUNG SPACE. PROVIDE PIPE INSULATION BY MANVILLE, OWENS CORNING, OR EQUAL J. PIPE INSULATION SHALL BE K INCH THICK FIBERGLASS WITH ALL SERVICE JACKET, OR M REQUIRED IN ACCORDANCE WITH LOCM ENERGY CODES. K. ORDER ALL EQUIPMENT REQUIRED WITHIN TEN DAYS UPON RECEIPT OF CONTRACT IN ORDER TO ENSURE TIMELY RECEIPT OF MATERIAL SUBSTITUTIONS AFTER THIS DATE DUE TO LACK OF PLACEMENT OF ORDER, WILL NOT BE APPROVED. L CLEAN, DISINFECT AND TEST ALL PLUMBING AND PIPING SYSTEMS AS REQUIRED BY LOCAL CODES AND LANDLORD'S CRnERM. M. PROVIDE PLUMBING FIXTURES AS SCHEDULED ON PUNS. SPRINKLER SPECIFICATION A SUBMIT SHOP DRAWING(S) TO ARCHITECT WITH EXACT LOCATION AND TYPE OF SPRINKLER HEADS. ARCHITECT TO REVIEW, DO NOT PURCHASE OR INSTALL HEADS UNTIL ARCHITECT HAS APPROVED LOCATIONS SHOWN ON SHOP DRAWING. B. THIS WORK SHALL BE INSTALLED IN CONFORMITY WITH APPLICABLE LOCAL ORDINANCES AND STATE STATUTES. ALL REQUIREMENTS OF THE CURRENT PLUMBING CODES, HEATING AND VENTILATING CODES, ENERGY OR CONSERVATION CODES, INSURANCE UNDERWRITER REQUIREMENTS AND NFPA BULLETINS MUST BE ME. C. STANDARDS AND SIZES WHICH MEET OR EXCEED THE ABOVE MENTIONED REQUIREMENTS SHALL BE INSIALLED AS DRAWN OR SPECIFIED. NOTHING IN THE SPECIFICATIONS OR DRAWINGS SHALL BE CONSTRUED TO PERMIT DEVIATION FROM THE REQUIREMENTS OF GOVERNING CODES. D. ALL LICENSES REWIRED IN CONNECTION WITH THIS WORK SHALL BE SECURED AND MAINTAINED BY THE PROPER RESPECTIVE CONTRACTOR WITH THE PROPER LOCAL OR STATE AUTHORITY HAVING JURISDICTION. E UPON COMPLETION OF THE SPRINKLER SYSTEM, THE FIRE PROTECTION CONTRACTOR SHALL HYDROSTATICALLY TEST ALL PIPING AT 200 PSI FOR TWO HOURS. MATERIAL AND TEST CERTIFICATES MUST BE PROPERLY FILLED OUT AND FURNISHED TO THE LANDLORD'S PROJECT MANAGER AT THE JOB SITE. F. PIPING IN FINISHED ROOMS SHALL BE CONCEALED IN PARITTONS. FURRED SPACES, OR SUSPENDED CEILINGS. IN UNFINISHED ROOMS, PIPING SHAT BE ARRANGED TO PROVIDE FOR A MAXIMUM OF HEAD ROOM. G. IT IS INTENDED THAT ALL APPARATUS BE LOCATED SYMMETRICAL WITH ARCHITECTURAL ELEMENTS AND SHALL BE INSIAILED AT THE HEIGHT AND LOCATIONS AS SHOWN ON THE ARCHITECTURAL DRAWINGS WHEREVER POSSIBLE. H. THE HANGERS SHALL BE SO LOCATED AS TO PROPERLY SUPPORT THE PIPES, RELIEVE STAN ON PIPES AND FITTINGS, AND AT THE SAME TIME ALLOW FOR AMPLE EXPANSION AND CONTRACTION. PIPING SHALL NOT BE HUNG FROM MEAL DECKING. BRIDGING, OR MECHANICAL EQUIPMENT SUCH AS PIPE OR DUCT. SPAN STRUCTURAL MEMBERS AS NECESSARY WITH UNISTRUT. I. ALL SPRINKLER PIPING IN THE BUILDING ABOVE GROUND SHALL BE SCHEDULE 40 BUCK STEEL WITH THREADED CONNECTIONS AND FITTINGS. Al PIPING SHALL BE INSTALLED IN CONFORMANCE WITH NEPA 313 REGULATIONS. J. THE FIRE SPRINKLER SYSTEM WILL BE COMPLETED BY THE WJDLORD's CONTRACTOR. SPRINKLER HEADS: EXPOSED PENDANT OR UPRIGHT — RELIABLE MODEL "G", 165 DEGREE, 8" ORIFICE, BRASS FINISH. FINISH CBUNG — RELIABLE "GAL" CONCEALED, 165 DEGREE, F ORIFICE, WHITE FINISH. K. PROVIDE BRASS PENDANT HEADS IN NON—VISIBLE MEAS WITH NO CEILINGS. L PROVIDE AUXILIARY DRAIN VALVE WHERE NECESSARY FOR PROPER DRAINING OF THE SYSTEM AND INSTALL PROPER IDENTIFICATION FOR EXPOSED OR CONCEALED VALVE. M. Al SPRINKLER HEAD SPACING BASED ON 130 SQUARE FEE PER HEAD IN SALES AREA AND 100 SQUARE FEE PER HEAD IN STOCK MEA VERIFY LANDLORD'S REQUIREMENTS. N. COORDINATE WORK SUCH THAT SYSTEM IS OPERATIONAL WHEN FIRE PROTECTION CONTRACTOR IS NOT ON PREMISES. 0. COORDINATE FIRE PROTECTION SYSTEM CONSTRUCTION AND OPERATION WITH LANDLORD'S INSURANCE PROVIDER. Alan J.Plutowski ARCHITECT 4125 Lakeland Ave. N., Suite 200 Minneapolis, Minnesota 55422 763-533-7171 fax: 763-533-7979 Consultants oDD RED WING SHOES 314 MW ST6E1 IBD MW', M UM 6 F boo) M -&b FY (Ni H Certification Project Information RED WING SHOES BUILD -OUT FOR NEW DEALER STORE Red Ting Shoe Store 9699 N. Michigan Rd, ate 1207 Carmel, Indiana 46092 Revisions Date: 04/06/18 Di By: MMS Checked By: MEA Job Number: 18RW-007 Sheet Information MECHANICAL SPECIFICATIONS COPYRIGHT 2018 ALAN J. PLUTOWSKI M390