HomeMy WebLinkAboutA013 - Wall Section8" CAST-IN-PLACE CONCRETE
FOUNDATION WALL
16"W X 12"H CONTINUOUS
CONCRETE FOOTER AT
MINIMUM 32" BELOW GRADE
FINISH GRADE
2" RIGID FOAM INSULATION
PEA GRAVEL FILL OVER 6 MIL
VISQUEEN VAPOR BARRIER
2X12 FLOOR JOISTS ON TREATED
2X6 SILL PLATE W/ 3/4" OSB
TONGUE & GROOVE SUBFLOOR
1X4 BASE & SHOE
H.O. PROVIDED FINISH FLOOR TBD
1/2" SMOOTH FINISH DRYWALL
2X6 STUD WALL @ 16" O.C.
W/ R-19 BATT INSULATION
7/16" OSB SHEATHING
& HOUSEWRAP
FIBER CEMENT FINISH SIDING
VENTED FIBER CEMENT SOFFIT
1X6 CEDAR FRIEZE
1X8 CEDAR FASCIA
6" SEAMLESS GUTTER
& DRIP EDGE
2X8 RAFTERS W/ R-30
BATT INSULATION
1/2" SMOOTH FINISH
DRYWALL CEILING
7/16" OSB DECKING
UNDERLAYMENT &
DIMENSIONAL SHINGLES
2X8 CEILING JOISTS @ 16" O.C.
W/ R-30 BATT INSULATION
1/2" SMOOTH FINISH
DRYWALL CEILING
#1
of
16
Date
:04.27.18
Sheet
:
Revision:
www.caseindy.com
99 E. Carmel Drive, Suite 100
Carmel, Indiana 46032
317.846.2600 317.846.2601(f)
These drawings have been
prepared by Case Design &
Remodeling solely for its use and
should not be reproduced or relied
upon by any other parties.
Dimensions shown or scaled are
subject to change per actual job
condition and must be verified.
Materials are to be supplied as
specified as equal or standard
when not uniquely specified.
Installed materials may vary in
appearance from drawings.
Reference manufacturer's product
data for actual appearance and
specifications.
Cr
e
r
a
r
Re
s
i
d
e
n
c
e
Su
n
r
o
o
m
Ad
d
i
t
i
o
n
Ke
i
t
h
& Ma
r
g
a
r
e
t
Cr
e
r
a
r
55
9
7
Ca
n
t
o
n
Dr
.
Ca
r
m
e
l
,
In
d
i
a
n
a
46
0
6
2
Approved By:
Date:
13
FINAL
Jordan Stocklin
Designer
jstocklin@caseindy.com
Dave Null
Lead Designer
dnull@caseindy.com
WALL SECTION
SCALE: 1/2" = 1'
#2 05.16.18
#3 06.08.18
07/02/18
Mike Sheeks