HomeMy WebLinkAboutA013 - Wall Section8" CAST-IN-PLACE CONCRETE FOUNDATION WALL 16"W X 12"H CONTINUOUS CONCRETE FOOTER AT MINIMUM 32" BELOW GRADE FINISH GRADE 2" RIGID FOAM INSULATION PEA GRAVEL FILL OVER 6 MIL VISQUEEN VAPOR BARRIER 2X12 FLOOR JOISTS ON TREATED 2X6 SILL PLATE W/ 3/4" OSB TONGUE & GROOVE SUBFLOOR 1X4 BASE & SHOE H.O. PROVIDED FINISH FLOOR TBD 1/2" SMOOTH FINISH DRYWALL 2X6 STUD WALL @ 16" O.C. W/ R-19 BATT INSULATION 7/16" OSB SHEATHING & HOUSEWRAP FIBER CEMENT FINISH SIDING VENTED FIBER CEMENT SOFFIT 1X6 CEDAR FRIEZE 1X8 CEDAR FASCIA 6" SEAMLESS GUTTER & DRIP EDGE 2X8 RAFTERS W/ R-30 BATT INSULATION 1/2" SMOOTH FINISH DRYWALL CEILING 7/16" OSB DECKING UNDERLAYMENT & DIMENSIONAL SHINGLES 2X8 CEILING JOISTS @ 16" O.C. W/ R-30 BATT INSULATION 1/2" SMOOTH FINISH DRYWALL CEILING #1 of 16 Date :04.27.18 Sheet : Revision: www.caseindy.com 99 E. Carmel Drive, Suite 100 Carmel, Indiana 46032 317.846.2600 317.846.2601(f) These drawings have been prepared by Case Design & Remodeling solely for its use and should not be reproduced or relied upon by any other parties. Dimensions shown or scaled are subject to change per actual job condition and must be verified. Materials are to be supplied as specified as equal or standard when not uniquely specified. Installed materials may vary in appearance from drawings. Reference manufacturer's product data for actual appearance and specifications. Cr e r a r Re s i d e n c e Su n r o o m Ad d i t i o n Ke i t h & Ma r g a r e t Cr e r a r 55 9 7 Ca n t o n Dr . Ca r m e l , In d i a n a 46 0 6 2 Approved By: Date: 13 FINAL Jordan Stocklin Designer jstocklin@caseindy.com Dave Null Lead Designer dnull@caseindy.com WALL SECTION SCALE: 1/2" = 1' #2 05.16.18 #3 06.08.18 07/02/18 Mike Sheeks